Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “flow test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Improvement of Subsonic Basic Research Tunnel Flow Quality as Applied to Wall Mounted Testing

A survey to determine the characteristics of a boundary layer that forms on the wall of the Subsonic Basic Research Tunnel has been performed. Early results showed significant differences in the velocity profiles as measured spanwise across the wall. An investigation of the flow in the upstream contraction revealed the presence of a separation bubble at the beginning of the contraction which caused much of the observed unsteadiness. Vortex generators were successfully applied to the contraction inlet to alleviate the separation. A final survey of the wall boundary layer revealed variations in the displacement and momentum thicknesses to be less than +/- 5% for all but the most upper portion of the wall. The flow quality was deemed adequate to continue the planned follow-on tests to help develop the semi-span test technique.

Howerton, Brian M.↗

RELAP5-3D Restart and Backup Verification Testing

Existing testing methodology for RELAP5-3D employs a set of test cases collected over two decades to test a variety of code features and run on a Linux or Windows platform. However, this set has numerous deficiencies in terms of code coverage, detail of comparison, running time, and testing fidelity of RELAP5-3D restart and backup capabilities. The test suite covers less than three quarters of the lines of code in the relap directory and just over half those in the environmental library. Even in terms of code features, many are not covered. Moreover, the test set runs many problems long past the point necessary to test the relevant features. It requires standard problems to run to completion. This is unnecessary for features can be tested in a short-running problem. For example, many trips and controls can be tested in the first few time steps, as can a number of fluid flow options. The testing system is also inaccurate. For the past decade, the diffem script has been the primary tool for checking that printouts from two different RELAP5-3D executables agree. This tool compares two output files to verify that all characters are the same except for those relating to date, time and a few other excluded items. The variable values printed on the output file are accurate to no more than eight decimal places. Therefore, calculations with errors in decimal places beyond those printed remain undetected. Finally, fidelity of restart is not tested except in the PVM sub-suite and backup is not specifically tested at all. When a restart is made from any midway point of the base-case transient, the restart must produce the same values. When a backup condition occurs, the code repeats advancements with the same time step. A perfect backup can be tested by forcing RELAP5 to perform a backup by falsely setting a backup condition flag at a user-specified-time. Comparison of the calculations of that run and those produced by the same input w/o the spurious condition should be identical. Backup testing is more difficult the other kinds of testing described above because it requires additional coding to implement. The testing system constructed and described in this document resolves all of these issues. A matrix of test features and short-running cases that exercise them is presented. A small information file that contains sufficient data to verify calculations to the last decimal place and bit is produced. This testing system is used to test base cases (called null testing) as well as restart and backup cases. The programming that implements these new capabilities is presented.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Measurement and evaluation of swirl-type flow in labyrinth seals of conventional turbine stages

The effects of load factor and rotor eccentricity were determined on flow conditions in test series for two stages. The results indicate that swirl-type entry flow follows the rules of potential swirl. Within the labyrinth cavities two spatial separated flow areas are considered. A dominating flow in periphera direction nearly fills the space between the sealing strips and the ceiling of the cavity. Below this flow, an area of axial mass transport is situated, with a slight peripheral component, limited on the nearest surroundings of the seals gap and the rotor surface. Between both flows, an exchange of energy takes place. Within the gaps, flow direction depends on axial velocity and therefore on variable flow contraction. A balance of energy within the seal and the cavities interprets the results of lateral force measurements as an influence of friction at the sealing strips surface and the rotating shaft surface. Stages with their blades put together in buckets by means of shrouding segments are particularly influenced by the rotating speed of the shrouding.

Hauck, L.↗

Studies of sidewall boundary layer in the Langley 0.3 meter transonic cryogenic tunnel with and without suction

Boundary layer measurements on the sidewalls of the Langley 0.3 Meter Transonic Cryogenic Tunnel were made to determine the effectiveness of the passive boundary layer bleed system over a Reynolds number range from 20 to 200 x 10 to the sixth power per meter at Mach numbers from 0.30 to 0.76. The tunnel sidewall boundary layer displacement thickness was about 2 percent of the width of the test section without the boundary layer bleed. Measured velocity profiles correlated well with the defect law of Hama. With the boundary layer bleed equivalent to about 2 percent of the test section mass flow, the boundary layer displacement thickness reduced to about 1 percent of the test section width, which is generally considered acceptable for testing airfoils. It was also noticed that effectiveness of the bleed was nearly independent of the Mach number and Reynolds number over the range of conditions tested. A comparison of the measured suction effectiveness of the bleed with the finite difference and integral methods of boundary layer calculation showed good agreement.

Murthy, A. V.↗

On the anomalies in single-jet hover suckdown data

The data from nine different investigations of the suckdown induced in ground effect by a single jet issuing from plates of various sizes and shapes have been examined and compared. The results show that the generally accepted method for estimating suckdown significantly underestimated the suckdown for most of the configurations. The study identified several factors that could contribute to the differences. These include ground board size, plate edge effects, jet flow quality, jet impingement angle, the size of the chamber in which the tests were run, and obstructions in the region above the model. Most of these factors have not been investigated and in many cases items such as the size of the test chamber, jet flow quality, ground board size, etc., have not even been shown in the documents reporting the investigation. A program to investigate the effects of these factors is recommended.

Kuhn, Richard E.↗

Design of a Microgravity Spray Cooling Experiment

An analytical and experimental study was conducted for the application of spray cooling in a microgravity and high-g environment. Experiments were carried out aboard the NASA KC-135 reduced gravity aircraft, which provided the microgravity and high-g environments. In reduced gravity, surface tension flow was observed around the spray nozzle, due to unconstrained liquid in the test chamber and flow reversal at the heat source. A transient analytical model was developed to predict the temperature and the spray heat transfer coefficient within the heated region. Comparison of the experimental transient temperature variation with analytical results showed good agreement for low heat input values. The transient analysis also verified that thermal equilibrium within the heated region could be reached during the 20-25s reduced gravity portion of the flight profile.

Baysinger, Kerri M.↗

Orifice Mass Flow Calculation in NASA's W-8 Single Stage Axial Compressor Facility

Updates to the orifice mass flow calculation for the W-8 Single Stage Axial Compressor Facility at NASA Glenn Research Center are provided to include the effect of humidity and incorporate ISO 5167. A methodology for including the effect of humidity into the inlet orifice mass flow calculation is provided. Orifice mass flow calculations provided by ASME PTC-19.5-2004, ASME MFC-3M-2004, ASME Fluid Meters, and ISO 5167 are compared for W-8's atmospheric inlet orifice plate. Differences in expansion factor and discharge coefficient given by these standards give a variation of about +/- 75% mass flow except for a few cases. A comparison of the calculations with an inlet static pressure mass flow correlation and a fan exit mass flow integration using test data from a 2017 turbofan rotor test in W-8 show good agreement between the inlet static pressure mass flow correlation, ISO 5167, and ASME Fluid Meters. While W-8's atmospheric inlet orifice plate violates the pipe diameter limit defined by each of the standards, the ISO 5167 is chosen to be the primary orifice mass flow calculation to use in the W-8 facility.

Aerodynamics↗

Effects of Confinement on Flame Spread in Microgravity

Solid fuel combustion experiments aboard the ISS examine the effects of confinement on a concurrent, purely-forced-flow flame spread in microgravity environment. The results for a thin, cotton-fiberglass-blended textile fabric fuel are presented. Flat baffles of differing materials are used to alter the radiative boundary conditions with transparent polycarbonate, black anodized aluminum (reflectance ~ 0), and highly polished aluminum (reflectance ~ 1). The baffles are parallel to the fuel sheet and placed symmetrically on each side. The inter-baffle distance is varied to change the boundary conditions for the flow. In all tests, samples are ignited at the upstream leading edge and allowed to burn to completion. Results show that the flame reaches a steady length and spread rate at low flow speeds (< 15 cm/s) for all tested inter-baffle distances. As the distance decreases, the flame length and spread rate first increase then decrease showing an optimal inter-baffle distance. For all baffle types, the flame either fails to ignite or extinguishes before reaching the end of the sample when the inter-baffle distance is too small (~ 1 cm). This is attributed to the reduction of oxygen supply to the flame zone and heat loss to the baffles. The results also show at the same inter-baffle distance, flame length and spread rate are highest for polished aluminum baffles, and lowest for transparent polycarbonate baffles. The differences are most prominent at intermediate tested baffle distances. While the radiative heat feedback from the baffles is expected to increase when the baffle distance decreases, the combustion is limited by the reduced oxygen supply. Near this limit, flame lengths and spread rates are similar for all baffle types.

Microgravity↗

Verification of Anisotropic Mesh Adaptation for Complex Aerospace Applications

The stabilized finite element solver, FUN3D-SFE, along with the grid mechanics package refine are verified for aerospace applications of laminar and turbulent flow simulations. The current verification exercise represents an extension of previous research using FUN3D-SFEwith adjoint-based mesh adaptation to generate highly anisotropic adapted meshes for inviscid problems. Adaptations are performed using a solution-based approach that controls the Lpnorm of Mach number interpolation error and an adjoint-based approach that controls the error in some output functional. Adaptive results are shown for laminar subsonic flow over a delta wing, laminar subsonic flow over ONERA M6 wing, inviscid supersonic flow over a sonic boom test case, and a turbulent flow over a high lift configuration (JAXA Standard Model). Mesh convergence results are also compared with results from FUN3D-FV (Finite Volume) whenever available. For all test cases considered, FUN3D-SFE gives significantly better accurate results than FUN3D-FV on coarse meshes.

Aravind Balan↗

Mass spectrometer measurements of test gas composition in a shock tunnel

Shock tunnels afford a means of generating hypersonic flow at high stagnation enthalpies, but they have the disadvantage that thermochemical effects make the composition of the test flow different to that of ambient air. The composition can be predicted by numerical calculations of the nozzle flow expansion, using simplified thermochemical models and, in the absence of experimental measurements, it has been necessary to accept the results given by these calculations. This note reports measurements of test gas composition, at stagnation enthalpies up to 12.5 MJ.kg(exp -1), taken with a time-of-flight mass spectrometer. Limited results have been obtained in previous measurements. These were taken at higher stagnation enthalpies, and used a quadruple mass spectrometer. The time-of-flight method was preferred here because it enabled a number of complete mass spectra to be obtained in each test, and because it gives good mass resolution over the range of interest with air (up to 50 a.m.a.).

Skinner, K. A.↗

Effect of nacelles on aerodynamic characteristics of an executive-jet model with simulated, partial-chord, laminar-flow-control wing glove

Tests were conducted in the Langley High-Speed 7- by 10-Foot Tunnel using a 1/10-scale model of an executive jet to examine the effects of the nacelles on the wing pressures and model longitudinal aerodynamic characteristics. For the present investigation, each wing panel was modified with a simulated, partial-chord, laminar-flow-control glove. Horizontal-tail effects were also briefly examined. The tests covered a range of Mach numbers from 0.40 to 0.82 and lift coefficients from 0.20 to 0.55. Oil-flow photographs of the wing at selected conditions are included.

Campbell, R. L.↗

Selection of LAW Glasses for FY 2016 SPFT Testing

The primary objective of this work is to provide recommendations for glasses to be used for Single Pass Flow Through (SPFT) testing in FY 2016. Since LAW glass formulation development is ongoing, particularly with respect to enhanced formulations with increased waste loading as compared to the present WTP baseline, it is anticipated that this report will be revised on an annual basis in order to provide appropriate recommendation for testing in each fiscal year.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Field Experiments and Model Validation: The EGS Collab Project

Implementing enhanced geothermal systems (EGS) will require improvements in understanding stimulation of crystalline rock to create appropriate flow pathways, and the ability to effectively simulate both the stimulation and the flow and transport processes in the resulting fracture network. The US Department of Energy (DOE) is addressing these and other challenges at multiple scales. The EGS Collab project, addressed here, is performing tests and modeling at the 10 m scale. The FORGE project is performing tests at the full reservoir scale. The EGS Collab team created an underground testbed at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, at a depth of approximately 1.5 km to examine hydraulic fracturing (Experiment 1). We are currently building a second testbed at SURF at a depth of about 1.25 km aimed at investigating shear stimulation (Experiment 2). In Experiment 1, we drilled eight boreholes in a well-characterized phyllite and installed geophysical sensors in six of them to create a well-instrumented testbed to allow careful monitoring of stimulation events and flow tests. Numerical simulation was used to answer key experimental design questions, to forecast fracture propagation trajectories and extents, and to analyze and evaluate results both in near-real-time and in detailed process studies. Stimulations performed in this testbed allowed quantification of processes occurring during stimulation and the examination of dynamic flow occurrences. Long-term ambient temperature and chilled water flow tests were performed in addition to many tracer tests to examine system behavior. Our second testbed, targeted at shear stimulation, is currently being built at the SURF Facility at a depth of about 1.25 km in amphibolite under a different set of stress and fracture conditions than Experiment 1.

artificial intelligence↗

Development and Validation of Methodology to Model Flow in Ventilation Systems Commonly Found in Nuclear Facilities - Phase II

In this report we present the results of the Phase II analysis and testing of the flow patterns encountered in the Alpha Gamma Hot Cell Facility (AGHCF), as well as the results from an opportunity to expand upon field test work from Phase I by the use of a Class IIIb laser. The addition to the Phase I work is covered before proceeding to the results of the Phase II work, followed by a summary of findings.

42 ENGINEERING↗

Flow Visualization of Liquid Hydrogen Line Chilldown Tests

We present experimental measurements of wall and fluid temperature during chill-down tests of a warm cryogenic line with liquid hydrogen. Synchronized video and fluid temperature measurements are used to interpret stream temperature profiles versus time. When cold liquid hydrogen starts to flow into the warm line, a sequence of flow regimes, spanning from all-vapor at the outset to bubbly with continuum liquid at the end can be observed at a location far downstream of the cold inlet. In this paper we propose interpretations to the observed flow regimes and fluid temperature histories for two chilldown methods, viz. trickle (i.e. continuous) flow and pulse flow. Calculations of heat flux from the wall to the fluid versus wall temperature indicate the presence of the transition/nucleate boiling regimes only. The present tests, run at typical Reynolds numbers of approx O(10 (exp 5)), are in sharp contrast to similar tests conducted at lower Reynolds numbers where a well-defined film boiling region is observed.

Line chill down↗

TPSAS-NF1676L-32577-DND

The ground testing of hypersonic vehicles requires the replication of the flow conditions at high speed and altitude. To produce these flow conditions, stored compressed air is expanded through a convergent-divergent nozzle to produce the required pressures and speed. However, the expansion process also cools the air, and so to match the flight temperatures, some form of heating needs to be employed. Vitiated heating is a common method, where the air is heated by burning fuel in the low speed side of the nozzle, and then oxygen is added to bring the level of O2 up to match that of standard air. The resulting flow no longer has the same composition as standard air, (except for the oxygen level), but rather contains combustion products, often referred to as vitiates as part of the mixture. The presence of these vitiates in the flow effects the wind tunnel test conditions. For example, the specific heat and molecular density are changed, the kinetics of combustion are altered and the flow features in the test article are altered. In this talk, the effects of the vitiates on the testing conditions and on the performance of test articles is described. Specific examples include the effects of molecular density on the flow, how combustion processes are altered by the presence of vitiates and how condensation of vitiates can alter the test conditions. In addition, the effect of the less common vitiates produced by arc-heated tunnels are mentioned, such as NO, non-thermal equilibrium and the presence of copper solids in the flow. Finally some thoughts on how large an effect these vitiates have on the test results are presented.

Andrew T Norris↗

Hardening of A6111-T4 Aluminum Alloy at Large Strains and Its Effect on Sheet Forming Operations

In a number of sheet metal stamping and joining processes, the material undergoes large plastic deformation exceeding the range of plastic strain achievable in a standard tensile test prior to material plastic instability. In order to extend the range of effective strains, the multistep rolling process was employed which enabled prestraining of aluminum sheet above 2.0 of true strain. Tensile testing of rolled samples was used to identify the flow stress corresponding to the level of prestrain: By varying the prestrain level, several data points were obtained for the studied flow curve. The numerical simulation using Abaqus software for the cold rolling process of aluminum strips confirmed that majority of the strip is deformed in plane strain compression condition. Performed simulation of the LDH test determined that earlier fracture might occur if the curve obtained via rolling–tensile testing approach is used versus traditional power law approximation and Voce law approximation. The results of simulation for the multistep drawing of a cylindrical cup revealed possible wrinkling in the die entry area during redrawing stage of the process if the rolling–tensile testing flow curve is employed.

36 MATERIALS SCIENCE↗