Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “error analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Effective structural impact detection and localization using convolutional neural network and Bayesian information fusion with limited sensors

Due to their unpredictable nature, many impact events (e.g., overheight vehicles striking on bridges) go unnoticed or get reported many hours later. However, they can induce structural failures or hidden damage that accelerates the structure’s long-term degradation. Therefore, prompt impact detection and localization strategies are essential for early warning of impact events and rapid maintenance of structures. Most existing impact detection strategies are developed for aircraft composite panels utilizing high-rate synchronized measurement from densely deployed sensors. Limited efforts have been made for infrastructure or human habitats which generally require large-scale but low-rate measurement. In particular, due to harsh environments (e.g., deep space habitats under meteoroids), structural impact localization must be robust to limited sensors (e.g., sensor damage during impacts) and multi-source errors (e.g., measurement errors). In this study, an effective impact detection and localization strategy is proposed using a limited number of vibration measurements, especially in harsh environments (e.g. in deep space). Convolutional neural networks are trained for each sensor node and are fused using Bayesian theory to improve the accuracy of impact localization. Special considerations are paid to evaluate the effect of both measurement error and modeling error in the analysis. The proposed strategy is illustrated using 1D structure, and further validated in 3D geodesic dome structure numerically. The results demonstrate that it can detect and localize impact events accurately and robustly on structures.

Yuguang Fu↗

Integrated fiducial sample mount and software for correlated microscopy

A novel design sample mount with integrated fiducials and software for assisting operators in easily and efficiently locating points of interest established in previous analytical sessions is described. The sample holder and software were evaluated with experiments to demonstrate the utility and ease of finding the same points of interest in two different microscopy instruments. Also, numerical analysis of expected errors in determining the same position with errors unbiased by a human operator was performed. Based on the results, issues related to acquiring reproducibility and best practices for using the sample mount and software were identified. Overall, the sample mount methodology allows data to be efficiently and easily collected on different instruments for the same sample location.

36 MATERIALS SCIENCE↗

Quality assurance for online adapted treatment plans: Benchmarking and delivery monitoring simulation

Purpose: An important challenge facing online adaptive radiation therapy is the development of feasible and efficient quality assurance (QA). This project aimed to validate the deliverability of online adapted plans and develop a proof-of-concept online delivery monitoring system for online adaptive radiation therapy QA. Methods: The first part of this project benchmarked automatically online adapted prostate treatment plans using traditional portal dosimetry IMRT QA. The portal dosimetry QA results of online adapted plans were compared to original (unadapted) plans as well as randomly selected prostate IMRT plans from our clinic. In the second part, an online delivery monitoring system was designed and validated via a simulated treatment with intentional multileaf collimator (MLC) errors. This system was based on inputs from the dynamic machine information (DMI), which continuously reports actual MLC positions and machine monitor units (MUs) at intervals of 50 ms or less during delivery. Based on the DMI, the system performed two levels of monitoring/verification during the delivery: (1) dynamic monitoring of cumulative fluence errors resulting from leaf position deviations and visualization using fluence error maps (FEMs); and (2) verification of MLC positions against the treatment plan for potential errors in MLC motion and data transfer at each control point. Validation of the online delivery monitoring system was performed by introducing intentional systematic MLC errors (ranging from 0.5 to 2 mm) to the DMI files for both leaf banks. These DMI files were analyzed by the proposed system to evaluate the system’s performance in quantifying errors and revealing the source of errors, as well as to understand patterns in the FEMs. In addition, FEMs from 210 actual prostate IMRT beams were analyzed using the proposed system to further validate its ability to catch and identify errors, as well as establish error magnitude baselines for prostate IMRT delivery. Results: Online adapted plans were found to have similar delivery accuracy in comparison to clinical IMRT plans when validated with portal dosimetry IMRT QA. FEMs for the simulated deliveries with intentional MLC errors exhibited distinct patterns for different MLC error magnitudes and directions, indicating that the proposed delivery monitoring system is highly specific in detecting the source of errors. Implementing the proposed QA system for online adapted plans revealed excellent delivery accuracy: over 99% of leaf position differences were within 0.5 mm, and >99% of pixels in the FEMs had fluence errors within 0.5 MU. Patterns present in the FEMs and MLC control point analysis for actual patient cases agreed with the error pattern analysis results, further validating the system’s ability to reveal and differentiate MLC deviations. Calculation of the fluence map based on the DMI was performed within 2 ms after receiving each DMI input. Conclusions: The proposed online delivery monitoring system requires minimal additional resources and time commitment to the current clinical workflow while still maintaining high sensitivity to leaf position errors and specificity to error types. The presented online delivery monitoring system therefore represents a promising QA system candidate for online adaptive radiation therapy.

07 ISOTOPE AND RADIATION SOURCES↗

Errors in Hadamard spectroscopy or imaging caused by imperfect masks

An analysis is given of the errors in Hadamard spectroscopy that are caused by transparent slits in the mask being systematically wider or else narrower than they should be. It is shown that if the input spectrum consists of a single line, the distorted spectrum that is actually calculated consists of this line, plus four small blips. When the transparent slits are too wide, these blips are of equal height and the same sign, one pair surrounding the line, and another pair displaced a certain distance from it. When the slits are too narrow, the displaced blips have the same amplitude but are negative.

Tai, M. H.↗

SU-E-J-235: Varian Portal Dosimetry Accuracy at Detecting Simulated Delivery Errors

Purpose: To use receiver operating characteristic (ROC) analysis to quantify the Varian Portal Dosimetry (VPD) application's ability to detect delivery errors in IMRT fields. Methods: EPID and VPD were calibrated/commissioned using vendor-recommended procedures. Five clinical plans comprising 56 modulated fields were analyzed using VPD. Treatment sites were: pelvis, prostate, brain, orbit, and base of tongue. Delivery was on a Varian Trilogy linear accelerator at 6MV using a Millenium120 multi-leaf collimator. Image pairs (VPD-predicted and measured) were exported in dicom format. Each detection test imported an image pair into Matlab, optionally inserted a simulated error (rectangular region with intensity raised or lowered) into the measured image, performed 3%/3mm gamma analysis, and saved the gamma distribution. For a given error, 56 negative tests (without error) were performed, one per 56 image pairs. Also, 560 positive tests (with error) with randomly selected image pairs and randomly selected in-field error location. Images were classified as errored (or error-free) if percent pixels with γ<κ was < (or ≥) τ. (Conventionally, κ=1 and τ=90%.) A ROC curve was generated from the 616 tests by varying τ. For a range of κ and τ, true/false positive/negative rates were calculated. This procedure was repeated for inserted errors of different sizes. VPD was considered to reliably detect an error if images were correctly classified as errored or error-free at least 95% of the time, for some κ+τ combination. Results: 20mm{sup 2} errors with intensity altered by ≥20% could be reliably detected, as could 10mm{sup 2} errors with intensity was altered by ≥50%. Errors with smaller size or intensity change could not be reliably detected. Conclusion: Varian Portal Dosimetry using 3%/3mm gamma analysis is capable of reliably detecting only those fluence errors that exceed the stated sizes. Images containing smaller errors can pass mathematical analysis, though may be detected by visual inspection. This work was not funded by Varian Oncology Systems. Some authors have other work partly funded by Varian Oncology Systems.

60 APPLIED LIFE SCIENCES↗

SU-E-T-545: MLC Distance Travelled as a Predictor for Motor Failure

Purpose: To study the frequency of Multi-Leaf Collimator (MLC) leaf failures, investigate methods to predict them and reduce linac downtime. Methods: A Varian HD120 MLC was used in our study. The hyperterminal MLC errors logged from 06/2012 to 12/2014 were collected. Along with the hyperterminal errors, the MLC motor changes and all other MLC interventions by the linear accelerator engineer were recorded. The MLC dynalog files were also recorded on a daily basis for each treatment and during linac QA. The dynalog files were analyzed to calculate root mean square errors (RMS) and cumulative MLC travel distance per motor. An in-house MatLab code was used to analyze all dynalog files, record RMS errors and calculate the distance each MLC traveled per day. Results: A total of 269 interventions were recorded over a period of 18 months. Of these, 146 included MLC motor leaf change, 39 T-nut replacements, and 84 MLC cleaning sessions. Leaves close to the middle of each side required the most maintenance. In the A bank, leaves A27 to A40 recorded 73% of all interventions, while the same leaves in the B bank counted for 52% of the interventions. On average, leaves in the middle of the bank had their motors changed approximately every 1500m of travel. Finally, it was found that the number of RMS errors increased prior to an MLC motor change. Conclusion: An MLC dynalog file analysis software was developed that can be used to log daily MLC usage. Our eighteen-month data analysis showed that there is a correlation between the distance an MLC travels, the RMS and the life of the MLC motor. We plan to use this tool to predict MLC motor failures and with proper and timely intervention, reduce the downtime of the linac during clinical hours.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Distance-preserving rigidity penalty on deformable image registration of multiple skeletal components in the neck

Purpose: This study aims at developing and testing a novel rigidity penalty suitable for the deformable registration of tightly located skeletal components in the head and neck from planning computed tomography (CT) and daily cone-beam CT (CBCT) scans of patients undergoing radiotherapy. Methods: The proposed rigidity penalty is designed to preserve intervoxel distances within each bony structure. This penalty was tested in the intensity-based B-spline deformable registration of five cervical vertebral bodies (C1–C5). The displacement vector fields (DVFs) from the registrations were compared to the DVFs generated by using rigid body motions of the cervical vertebrae, measured by the surface registration of vertebrae delineated on CT and CBCT images. Twenty five pairs of planning CT (reference) and treatment CBCTs (target) from five patients were aligned without and with the penalty. An existing penalty based on the orthonormality of the deformation gradient tensor was also tested and the effects of the penalties compared. Results: The mean magnitude of the maximum registration error with the proposed distance-preserving penalty was (0.86, 1.12, 1.33) mm compared to (2.11, 2.49, 2.46) without penalty and (1.53, 1.64, 1.64) with the existing orthonormality-based penalty. The improvement in the accuracy of the deformable image registration was also verified by comparing the Procrustes distance between the DVFs. With the proposed penalty, the average distance was 0.11 (σ 0.03 mm) which is smaller than 0.53 (0.1 mm) without penalty and 0.28 (0.04 mm) with the orthonormality-based penalty. Conclusions: The accuracy of aligning multiple bony elements was improved by using the proposed distance-preserving rigidity penalty. The voxel-based statistical analysis of the registration error shows that the proposed penalty improved the integrity of the DVFs within the vertebral bodies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Analysis of open-loop conical scan pointing error and variance estimators

General pointing error and variance estimators for an open-loop conical scan (conscan) system are derived and analyzed. The conscan algorithm is modeled as a weighted least-squares estimator whose inputs are samples of receiver carrier power and its associated measurement uncertainty. When the assumptions of constant measurement noise and zero pointing error estimation are applied, the variance equation is then strictly a function of the carrier power to uncertainty ratio and the operator selectable radius and period input to the algorithm. The performance equation is applied to a 34-m mirror-based beam-waveguide conscan system interfaced with the Block V Receiver Subsystem tracking a Ka-band (32-GHz) downlink. It is shown that for a carrier-to-noise power ratio greater than or equal to 30 dB-Hz, the conscan period for Ka-band operation may be chosen well below the current DSN minimum of 32 sec. The analysis presented forms the basis of future conscan work in both research and development as well as for the upcoming DSN antenna controller upgrade for the new DSS-24 34-m beam-waveguide antenna.

Alvarez, L. S.↗

nCTEQ15 - Global analysis of nuclear parton distributions with uncertainties

We present the first official release of the nCTEQ nuclear parton distribution functions with errors. The main addition to the previous nCTEQ PDFs is the introduction of PDF uncertainties based on the Hessian method. Another important addition is the inclusion of pion production data from RHIC that give us a handle on constraining the gluon PDF. This contribution summarizes our results from arXiv:1509.00792, and concentrates on the comparison with other groups providing nuclear parton distributions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Stochastic Richardson Extrapolation Based Numerical Error Estimation for Kinetic Plasma Simulations

We present a numerical error estimation technique specifically formulated to deal with stochastic code output with multiple discretization parameters. This method is based on multiple fits to an error model with arbitrary convergence rates and cross-coupling terms, performed using nonlinear optimization. The fitting approach varies by the type of residual norm which influences the importance of outliers, and weights which influences the relative importance of data points in the coarse and refined regions of discretization parameter space. To account for the influence of stochastic noise, these fits are performed on multiple bootstrap values based on the underlying response data set. Using an automated discretization domain selection scheme, the fits are performed on a series of reduced sets of discretization levels in order to find an optimal fully-converged result estimate in the minimum variance sense; this automated approach enables straightforward analysis of multiple quantities of interest and/or time and spatially-dependent response data. The overall numerical error analysis method is useful for verification and validation problems for stochastic simulation methods and forms a key component in the overall uncertainty quantification process. The method was demonstrated for steady and unsteady electron diode problems simulated using a particle-in-cell kinetic plasma code, demonstrating excellent results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Summary of Validation Studies for the Integrated TIGER Series Performed on ACORN Plus-up 218468/99

The Integrated TIGER Series (ITS) transport code is a valuable tool for photon-electron transport. A seven-problem validation suite exists to make sure that the ITS transport code works as intended. It is important to ensure that data from benchmark problems is correctly compared to simulated data. Additionally, the validation suite did not previously make use of a consistent quantitative metric for comparing experimental and simulated datasets. To this end, the goal of this long-term project was to expand the validation suite both in problem type and in the quality of the error assessment. To accomplish that, the seven validation problems in the suite were examined for potential drawbacks. When a drawback was identified, the problems were ranked based on severity of the drawback and approachability of a solution. We determined that meaningful improvements could be made to the validation suite by improving the analysis for the Lockwood Albedo problem and by introducing the Ross dataset as an eighth problem to the suite. The Lockwood error analysis has been completed and will be integrated in the future. The Ross data is unfinished, but significant progress has been made towards analysis.

97 MATHEMATICS AND COMPUTING↗

Lost in Translation: the Case for Integrated Testing

The building of a spacecraft is complex and often involves multiple suppliers and companies that have their own designs and processes. Standards have been developed across the industries to reduce the chances for critical flight errors at the system level, but the spacecraft is still vulnerable to the introduction of critical errors during integration of these systems. Critical errors can occur at any time during the process and in many cases, human reliability analysis (HRA) identifies human error as a risk driver. Most programs have a test plan in place that is intended to catch these errors, but it is not uncommon for schedule and cost stress to result in less testing than initially planned. Therefore, integrated testing, or "testing as you fly," is essential as a final check on the design and assembly to catch any errors prior to the mission. This presentation will outline the unique benefits of integrated testing by catching critical flight errors that can otherwise go undetected, discuss HRA methods that are used to identify opportunities for human error, lessons learned and challenges over ownership of testing will be discussed.

Young, Aaron↗

Spatiotemporal Filtering Using Principal Component Analysis and Karhunen-Loeve Expansion Approaches for Regional GPS Network Analysis

Spatial filtering is an effective way to improve the precision of coordinate time series for regional GPS networks by reducing so-called common mode errors, thereby providing better resolution for detecting weak or transient deformation signals. The commonly used approach to regional filtering assumes that the common mode error is spatially uniform, which is a good approximation for networks of hundreds of kilometers extent, but breaks down as the spatial extent increases. A more rigorous approach should remove the assumption of spatially uniform distribution and let the data themselves reveal the spatial distribution of the common mode error. The principal component analysis (PCA) and the Karhunen-Loeve expansion (KLE) both decompose network time series into a set of temporally varying modes and their spatial responses. Therefore they provide a mathematical framework to perform spatiotemporal filtering.We apply the combination of PCA and KLE to daily station coordinate time series of the Southern California Integrated GPS Network (SCIGN) for the period 2000 to 2004. We demonstrate that spatially and temporally correlated common mode errors are the dominant error source in daily GPS solutions. The spatial characteristics of the common mode errors are close to uniform for all east, north, and vertical components, which implies a very long wavelength source for the common mode errors, compared to the spatial extent of the GPS network in southern California. Furthermore, the common mode errors exhibit temporally nonrandom patterns.

displacement↗

Multifield optimization intensity-modulated proton therapy (MFO-IMPT) for prostate cancer: Robustness analysis through simulation of rotational and translational alignment errors

To evaluate the dosimetric consequences of rotational and translational alignment errors in patients receiving intensity-modulated proton therapy with multifield optimization (MFO-IMPT) for prostate cancer. Ten control patients with localized prostate cancer underwent treatment planning for MFO-IMPT. Rotational and translation errors were simulated along each of 3 axes: anterior-posterior (A-P), superior-inferior (S-I), and left-right. Clinical target-volume (CTV) coverage remained high with all alignment errors simulated. Rotational errors did not result in significant rectum or bladder dose perturbations. Translational errors resulted in larger dose perturbations to the bladder and rectum. Perturbations in rectum and bladder doses were minimal for rotational errors and larger for translational errors. Rectum V45 and V70 increased most with A-P misalignment, whereas bladder V45 and V70 changed most with S-I misalignment. The bladder and rectum V45 and V70 remained acceptable even with extreme alignment errors. Even with S-I and A-P translational errors of up to 5 mm, the dosimetric profile of MFO-IMPT remained favorable. MFO-IMPT for localized prostate cancer results in robust coverage of the CTV without clinically meaningful dose perturbations to normal tissue despite extreme rotational and translational alignment errors.

61 RADIATION PROTECTION AND DOSIMETRY↗

MS25: Materials Science-Focused Benchmark Data Set for Machine Learning Interatomic Potentials

Here, we present MS25, a benchmark data set for evaluating machine learning interatomic potentials (MLIPs) across diverse materials-relevant systems including MgO surfaces, liquid water, zeolites, a catalytic Pt surface reaction, high-entropy alloys (HEAs), and disordered Zr-oxides. Five MLIP architectures (MACE, NequIP, Allegro, MTP, and Torch-ANI) are trained and tested, focusing not only on traditional metrics (energies, forces, and stresses) but also explicitly validating derived physical observables such as lattice constants, volumes, and reaction barriers. We find that most models reach comparable accuracy on standard error metrics across the simple systems, although equivariant MLIPs offer 1.5–2× improvements over nonequivariant MLIPs in energy and force error for structurally complex or compositionally disordered environments such as HEAs and Zr–O systems. Our analysis highlights that low errors in energy and force predictions do not guarantee reliable observables, emphasizing the necessity of explicit validation. We demonstrate limitations in cross-framework transferability, as models trained on one zeolite framework (CHA) fail to reliably generalize to predictions of structurally distinct frameworks (e.g., MFI). Size-extensive tests show some dependence on system size for MgO, resulting from forced periodicity. The HEA and Zr–O data sets are identified as challenging tests for future benchmarks and MLIP model architecture developments as they show significant differentiation in error between MLIP architectures and are still relatively difficult at 1000 training images. Moving forward, we recommend that benchmarking efforts shift their focus from marginal accuracy improvements in energy and force errors toward identifying and understanding model failure modes, rigorously assessing transferability, and evaluating how their errors affect observable predictions. For researchers looking to choose an MLIP architecture, we suggest selecting equivariant MLIP architectures if the complexity of the system is a challenge. For simple materials problems, auxiliary features such as integration with molecular dynamics engines, trade-offs between computational data set generation cost vs MLIP inference speed, and framework integration may play a more important decision factor than small differences in error metrics that are unlikely to matter for production-level research.

chemical structure↗

Behavior and mechanisms of Doppler wind lidar error in varying stability regimes

Abstract. Wind lidars are widespread and important tools in atmospheric observations. An intrinsic part of lidar measurement error is due to atmospheric variability in the remote-sensing scan volume. This study describes and quantifies the distribution of measurement error due to turbulence in varying atmospheric stability. While the lidar error model is general, we demonstrate the approach using large ensembles of virtual WindCube V2 lidar performing a profiling Doppler-beam-swinging scan in quasi-stationary large-eddy simulations (LESs) of convective and stable boundary layers. Error trends vary with the stability regime, time averaging of results, and observation height. A systematic analysis of the observation error explains dominant mechanisms and supports the findings of the empirical results. Treating the error under a random variable framework allows for informed predictions about the effect of different configurations or conditions on lidar performance. Convective conditions are most prone to large errors (up to 1.5 m s−1 in 1 Hz wind speed in strong convection), driven by the large vertical velocity variances in convective conditions and the high elevation angle of the scanning beams (62∘). Range-gate weighting induces a negative bias into the horizontal wind speeds near the surface shear layer (−0.2 m s−1 in the stable test case). Errors in the horizontal wind speed and direction computed from the wind components are sensitive to the background wind speed but have negligible dependence on the relative orientation of the instrument. Especially during low winds and in the presence of large errors in the horizontal velocity estimates, the reported wind speed is subject to a systematic positive bias (up to 0.4 m s−1 in 1 Hz measurements in strong convection). Vector time-averaged measurements can improve the behavior of the error distributions (reducing the 10 min wind speed error standard deviation to <0.3 m s−1 and the bias to <0.1 m s−1 in strong convection) with a predictable effectiveness related to the number of decorrelated samples in the time window. Hybrid schemes weighting the 10 min scalar- and vector-averaged lidar measurements are shown to be effective at reducing the wind speed biases compared to cup measurements in most of the simulated conditions, with time averages longer than 10 min recommended for best use in some unstable conditions. The approach in decomposing the error mechanisms with the help of the LES flow field could be extended to more complex measurement scenarios and scans.

17 WIND ENERGY↗