Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electronic damage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Ion irradiation of electronic-type-separated single wall carbon nanotubes: A model for radiation effects in nanostructured carbon

The structural and electrical properties of electronic-type-separated (metallic and semiconducting) single wall carbon nanotube (SWCNT) thin-films have been investigated after irradiation with 150 keV {sup 11}B{sup +} and 150 keV {sup 31}P{sup +} with fluences ranging from 10{sup 12} to 10{sup 15} ions/cm{sup 2}. Raman spectroscopy results indicate that the ratio of the Raman D to G Prime band peak intensities (D/G Prime ) is a more sensitive indicator of SWCNT structural modification induced by ion irradiation by one order of magnitude compared to the ratio of the Raman D to G band peak intensities (D/G). The increase in sheet resistance (R{sub s}) of the thin-films follows a similar trend as the D/G Prime ratio, suggesting that the radiation induced variation in bulk electrical transport for both electronic-types is equal and related to localized defect generation. The characterization results for the various samples are compared based on the displacement damage dose (DDD) imparted to the sample, which is material and damage source independent. Therefore, it is possible to extend the analysis to include data from irradiation of transferred CVD-graphene films on SiO{sub 2}/Si substrates using 35 keV C{sup +} ions, and compare the observed changes at equivalent levels of ion irradiation-induced damage to that observed in the SWCNT thin-film samples. Ultimately, a model is developed for the prediction of the radiation response of nanostructured carbon materials based on the DDD for any incident ion with low-energy recoil spectra. The model is also related to the defect concentration, and subsequently the effective defect-to-defect length, and yields a maximum defect concentration (minimum defect-to-defect length) above which the bulk electrical transport properties in SWCNT thin-films and large graphene-based electronic devices rapidly degrade when exposed to harsh environments.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of irradiation temperature on void swelling of China Low Activation Martensitic steel (CLAM)

CLAM is one composition of a Reduced Activation Ferritic/Martensitic steel (RAFM), which is being studied in a number of institutes and universities in China. The effect of electron-beam irradiation temperature on irradiation swelling of CLAM was investigated by using a 1250 kV High Voltage Electron Microscope (HVEM). In-situ microstructural observations indicated that voids formed at each experimental temperature - 723 K, 773 K and 823 K. The size and number density of voids increased with increasing irradiation dose at each temperature. The results show that CLAM has good swelling resistance. The maximum void swelling was produced at 723 K; the swelling was about 0.3% when the irradiation damage was 13.8 dpa.

36 MATERIALS SCIENCE↗

Lawrence Bragg, microdiffraction and X-ray lasers

We trace the historical development of W. L. Bragg's `law' and the key experimental observation which made it possible using polychromatic radiation at a time when neither X-ray wavelengths nor cell constants were known. This led, through his phasing and solving large mineral structures (without use of a computer), to work on metals, proteins, bubble rafts and his X-ray microscope. The relationship of this to early X-ray microdiffraction is outlined, followed by a brief review of electron microdiffraction methods, where electron-probe sizes smaller than one unit cell can be formed with an interesting `failure' of Bragg's law. We end with a review of recent femtosecond X-ray `snapshot' diffraction from protein nanocrystals, using an X-ray laser which generates pulses so short that they terminate before radiation damage can commence, yet subsequently destroy the sample. Using short pulses instead of freezing, the nexus between dose, resolution and crystal size has been broken, opening the way to time-resolved diffraction without damage for a stream of identical particles.

36 MATERIALS SCIENCE↗

Temporal changes in sarcomere lesions of rat adductor longus muscles during hindlimb reloading

Focal sarcomere disruptions were previously observed in adductor longus muscles of rats flown approximately two weeks aboard the Cosmos 1887 and 2044 biosatellite flights. These lesions, characterized by breakage and loss of myofilaments and Z-line streaming, resembled damage induced by unaccustomed exercise that includes eccentric contractions in which muscles lengthen as they develop tension. We hypothesized that sarcomere lesions in atrophied muscles of space flow rats were not produced in microgravity by muscle unloading but resulted from muscle reloading upon re-exposure to terrestrial gravity. To test this hypothesis, we examined temporal changes in sarcomere integrity of adductor longus muscles from rats subjected to 12.5 days of hindlimb suspension unloading and subsequent reloading by return to vivarium cages for 0, 6, 12, or 48 hours of normal weightbearing. Our ultrastructural observations suggested that muscle unloading (0 h reloading) induced myofibril misalignment associated with myofiber atrophy. Muscle reloading for 6 hours induced focal sarcomere lesions in which cross striations were abnormally widened. Such lesions were electron lucent due to extensive myofilament loss. Lesions in reloaded muscles showed rapid restructuring. By 12 hours of reloading, lesions were moderately stained foci and by 48 hours darkly stained foci in which the pattern of cross striations was indistinct at the light and electron microscopic levels. These lesions were spanned by Z-line-like electron dense filamentous material. Our findings suggest a new role for Z-line streaming in lesion restructuring: rather than an antecedent to damage, this type of Z-line streaming may be indicative of rapid, early sarcomere repair.

Non-NASA Center↗

The Influence of Grain Boundary Type upon Damage Evolution at Grain Boundary Interfaces

In a prior work, it was found that grain boundary structure strongly influences damage evolution at grain boundaries in copper samples subjected to either shock compression or incipient spall. Here, several grain boundaries with different grain boundary structures, including a {Sigma}3 (10-1) boundary, are interrogated via conventional transmission electron microscopy (TEM) and high-resolution transmission electron microscopy (HRTEM) to investigate the effects of atomic-scale structural differences on grain boundary strength and mobility. Boundaries are studied both before and after shock compression at a peak shock stress of 10 GPa. Results of the TEM and HRTEM work are used in conjunction with MD modeling to propose a model for shock-induced damage evolution at grain boundary interfaces that is dependent upon coincidence.

36 MATERIALS SCIENCE↗

Radiation Damage in XFEL: Case study from the oxygen-evolving complex of Photosystem II

Structural changes induced by radiation damage in X-ray crystallography hinder the ability to understand the structure/function relationship in chemical reactions. Serial femtosecond crystallography overcomes this problem by exposing the sample to very short and intense laser pulse leading to measurement before destruction. Here we use molecular modeling to map the radiation damage during the 10–50 fs to the intensity, the energy and the time duration of the laser pulse on the oxygen-evolving complex (OEC) of photosystem II. In the model, the nuclei move classically in a fully quantum potential created by electron density under the effect of strong laser pulse in the Ehrenfest dynamics regime. The results show that the Mn-Mn and Mn-Ca distances are less affected by radiation damage due to the their heavy masses, while one μ-oxo bridge (O5) moves significantly. The radiation damage may induce conformational changes of the water ligands but only bond elongation for the amino acids ligands. These effects are relatively intensity independent from 10 16 to 10 17 W/cm 2 , but changes increase dramatically if the beam intensity is increased to 10 18 W/cm 2 . Finally, in addition, the self amplified spontaneous emission (SASE) nature of the laser beam does not affect the dynamics of the ions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Mitigation of Hot-Spots in Photovoltaic Systems Using Distributed Power Electronics

In the presence of partial shading and other mismatch factors, bypass diodes may not offer complete elimination of excessive power dissipation due to cell reverse biasing, commonly referred to as hot-spotting in photovoltaic (PV) systems. As a result, PV systems may experience higher failure rates and accelerated ageing. In this paper, a cell-level simulation model is used to assess occurrence of hot-spotting events in a representative residential rooftop system scenario featuring a moderate shading environment. The approach is further used to examine how well distributed power electronics converters mitigate the effects of partial shading and other sources of mismatch by preventing activation of bypass diodes and thereby reducing the chances of heavy power dissipation and hot-spotting in mismatched cells. The simulation results confirm that the occurrence of heavy power dissipation is reduced in all distributed power electronics architectures, and that submodule-level converters offer nearly 100% mitigation of hot-spotting. In addition, the paper further elaborates on the possibility of hot-spot-induced permanent damage, predicting a lifetime energy loss above 15%. In conclusion, this energy loss is fully recoverable with submodule-level power converters that mitigate hot-spotting and prevent the damage.

14 SOLAR ENERGY↗

Cytological Characteristics of a Heterogeneous Population of Hepatocellular Carcinoma-29 Cells after Injection of Lithium Carbonate in the Experiment

Five cytological types of hepatocellular carcinoma-29 (G-29) grown in the muscle tissue of the thigh of experimental animals were identified by transmission electron microscopy; 89% of these were poorly differentiated type I-III cells. Lithium in a concentration of 20 mM produced a damaging effect on poorly differentiated G-29 cells: the number of cells with zones of intracellular component destruction and volume density of these zones increased, while volume density of cisterns of endoplasmic reticulum decreased. These results suggest that lithium carbonate can cause destructive changes in the heterogeneous population of G-29 cells during in vivo tumor development.

60 APPLIED LIFE SCIENCES↗

Nanoscale observation of the natural structure of milk-fat globules and casein micelles in the liquid condition using a scanning electron assisted dielectric microscopy

Recently, aqueous nanoparticles have been used in drug-delivery systems for new type medicines. In particular, milk-casein micelles have been used as drug nanocarriers for targeting cancer cells. Therefore, nanostructure observation of particles and micelles in their native liquid condition is indispensable for analysing their function and mechanisms. However, traditional optical and scanning electron microscopy have difficulty observing the nanostructures of aqueous micelles. Recently, we developed a novel imaging technique called scanning electron-assisted dielectric microscopy (SE-ADM) that enables observation of various biological specimens in water with very little radiation damage and high-contrast imaging without staining or fixation at an 8-nm spatial resolution. In this study, for the first time, we show that the SE-ADM system is capable of high-resolution observation of whole-milk specimens in their natural state. Moreover, we successfully observe the casein micelles and milk-fat globules in an intact liquid condition. Our SE-ADM system can be applied to various biological particles and micelles in a native liquid state. - Highlights: • We directly observed the whole-milk specimens of natural state using our SE-ADM. • We have performed clear observation of milk-fat globules and casein micelles. • Our system images the white milk-fat globules with small black casein micelles. • SE-ADM system can be applied to various aqueous nanoparticle specimens.

60 APPLIED LIFE SCIENCES↗

Heavy ion irradiation-induced microstructural evolution in pyrochlore Lu{sub 2}Ti{sub 2}O{sub 7} at room temperature and 723 K

Polycrystalline pyrochlore Lu{sub 2}Ti{sub 2}O{sub 7} pellets were irradiated with 600 keV Kr{sup 3+} at room temperature and 723 K to a fluence of 4×10{sup 15} ions/cm{sup 2}, corresponding to an average ballistic damage dose of 10 displacements per atom in the peak damage region. Irradiation-induced microstructural evolution was examined by grazing incidence X-ray diffraction, and cross-sectional transmission electron microscopy. Incomplete amorphization was observed in the sample irradiated at room temperature due to the formation of nano-crystal which has the identical structure of pyrochlore, and the formation of nano-crystal is attributed to the mechanism of epitaxial recrystallization. However, an ordered pyrochlore phase to a swelling disordered fluorite phase transformation is occurred for the Lu{sub 2}Ti{sub 2}O{sub 7} sample irradiated at 723 K, which is due to the disordering of metal cations and anion vacancies. - Graphical Abstract: Polycrystalline pyrochlore Lu{sub 2}Ti{sub 2}O{sub 7} pellets were irradiated with 600 keV Kr{sup 3+} to a fluence of 4×10{sup 15} ions/cm{sup 2} at room temperature and 723 K, Incomplete amorphization was observed in the sample irradiated at room temperature due to the formation of nano-crystal. However, an ordered pyrochlore phase to a swelling disordered fluorite phase transformation is occurred for the Lu{sub 2}Ti{sub 2}O{sub 7} sample irradiated at 723 K, which is due to the disordering of metal cations and anion vacancies. - Highlights: Pyrochlore Lu{sub 2}Ti{sub 2}O{sub 7} pellets were irradiated by heavy ions at RT and 723 K. At RT irradiation, ~75% of amorphization was achieved. The nano-crystals were formed in the damage layer at RT irradiation. The formed nano-crystals enhanced the radiation tolerance of Lu{sub 2}Ti{sub 2}O{sub 7}. A pyrochlore to fluorite phase transformation was observed at 723 K irradiation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Defect production in strained p-type Si{sub 1-x}Ge{sub x} by Er implantation

Strained p-Si{sub 1-x}Ge{sub x} (x=5.3%, 10.2%, and 15.4%) was irradiated at room temperature with 160 keV {sup 166}Er{sup 2+} ions to a fluence of 1x10{sup 10} or 3x10{sup 13} Er/cm{sup 2}. The defects induced by ion implantation were investigated experimentally using high-resolution x-ray diffraction, Rutherford backscattering and channeling spectroscopy, and deep level transient spectroscopy. X-ray diffraction indicates that the damage induced by Er implantation produces a slight perpendicular expansion of the SiGe lattice. For all compositions, channeling measurements reveal that Er implantation in p-Si{sub 1-x}Ge{sub x} to a fluence of 3x10{sup 13} Er/cm{sup 2} induces an amorphous region below the Si{sub 1-x}Ge{sub x} surface. Annealing at 850 deg. C for 30 s, results in a reduction in damage density, a relaxation of the implantation-induced perpendicular expansion of the SiGe lattice in the implanted region, while a more pronounced relaxation of the compressive strain SiGe is observed for higher Ge content (x=0.10 and 0.15). On the other hand, for the annealed SiGe samples that were implanted with Er at the fluence of 10{sup 10} Er/cm{sup 2}, the compressive strain in the SiGe layer is nearly completely retained. Deep level transient spectroscopy studies indicate that two prominent defects with discrete energy levels above the valence band are introduced during Er implantation. Their activation energy was found to decrease with increasing Ge content. However, the relatively large local strain induced by high fluence Er implantation reduces the activation energy by 40 meV with respect to the low fluence Er implanted p-Si{sub 1-x}Ge{sub x}. This shift (40 meV) in the activation energy remains constant regardless of the Ge content, suggesting that the Si{sub 1-x}Ge{sub x} layers remained fully strained after Er implantation. The observed defects are further compared to those introduced by alpha particle irradiation and electron beam metal deposition. The results indicate that defects introduced by Er implantation have similar electronic properties as those of defects detected after electron beam deposition and alpha particle irradiation. Therefore, it is concluded that these defects are due to the Er implantation-induced damage and not to the Er species specifically.

36 MATERIALS SCIENCE↗

Microstructure evolution in carbon-ion implanted sapphire

Carbon ions of MeV energy were implanted into sapphire to fluences of 1x10{sup 17} or 2x10{sup 17} cm{sup -2} and thermally annealed in forming gas (4% H in Ar) for 1 h. Secondary ion mass spectroscopy results obtained from the lower dose implant showed retention of implanted carbon and accumulation of H near the end of range in the C implanted and annealed sample. Three distinct regions were identified by transmission electron microscopy of the implanted region in the higher dose implant. First, in the near surface region, was a low damage region (L{sub 1}) composed of crystalline sapphire and a high density of plateletlike defects. Underneath this was a thin, highly damaged and amorphized region (L{sub 2}) near the end of range in which a mixture of i-carbon and nanodiamond phases are present. Finally, there was a pristine, undamaged sapphire region (L{sub 3}) beyond the end of range. In the annealed sample some evidence of the presence of diamond nanoclusters was found deep within the implanted layer near the projected range of the C ions. These results are compared with our previous work on carbon implanted quartz in which nanodiamond phases were formed only a few tens of nanometers from the surface, a considerable distance from the projected range of the ions, suggesting that significant out diffusion of the implanted carbon had occurred.

36 MATERIALS SCIENCE↗

Radiation damage study of POCO ZXF-5Q graphite for neutrino production targets using 4.5 MeV helium ions

To address the challenges of increased beam power and target survivability associated with next-generation particle production beam lines, high dose, high-energy proton beam conditions are simulated using irradiation from low-energy ion beams. A low-energy ion irradiation study of POCO ZXF-5Q graphite under conditions similar to those of the NuMI NT-02 neutrino production target at the Fermi National Accelerator Laboratory is reported. Helium ion irradiation was performed at 100 ∘ C to a maximum damage level of 0.9 displacements per atom (DPA). Irradiation induced hardening, swelling of the irradiated region, inter-plane lattice expansion, and intraplane lattice contraction with increasing ion fluence was observed using micromechanical (nanoindentation, atomic force microscopy) and electron microscopy (high-resolution imaging, selected area diffraction) characterization. Similar changes were also observed in post irradiation examination of the NT-02 target indicating that ion irradiation can be a valuable tool for estimating radiation damage in proton beam targets. Caution must be exercised though, because the hardening, lattice alteration, and swelling occur to different magnitudes for a given damage level. The observed hardening and embrittlement were greater for ion irradiated graphite. For He ion irradiated samples the lattice spacing changes were smaller at low damage levels (78% less expansion and 71% less contraction at 0.1 DPA) and larger at high damage levels (38% more expansion and 5% more contraction at 0.9 DPA) relative to that observed in the NT-02 target. The magnitude of swelling was 8.5× greater under ion irradiation which is influenced by the differing damage gradients and inclusion of implanted He ions in the region of interest.

43 PARTICLE ACCELERATORS↗

Computational modeling of coupled mechanical damage and electrochemistry in ternary oxide composite electrodes

Performance degradation of ternary layered oxide cathodes largely originates from their loss of structural integrity in cyclic usage. Mechanical damage, such as intergranular fracture of the active particles, is not only a mechanical cleavage process but also interferes with electrochemical kinetics such as infiltration of liquid electrolyte, surface corrosion of the constituent primary particles, and may eventually isolate the primary grains from the electron conducting network. Here, in this work, we develop a computational framework that integrates electrochemistry of a LiNi x Mn y Co 1−x−y O 2 (NMC) composite cathode with mechanical damage of the active particles. To fully examine the intricate chemomechanical behavior of the electrode, we evaluate the effects of the anisotropic material properties, the influence of mechanical potential on Li transport, and the concurrent intergranular fracture and electrolyte penetration along the grain boundaries upon multiple cycles. Electrolyte infiltration benefits capacity retention but aggravates further mechanical damage by corrosion. Structural failure mostly occurs in the first charging due to the anisotropic mechanical strain between the primary grains, while the resulting damage remains stable in the later few cycles. The results are consistent with experimental observations and the integration of electrochemistry and mechanical failure enables a step further understanding of the complex mechanism of battery degradation.

Battery degradation↗

Oxidant damage during and after spaceflight

The objectives of this study were to assess oxidant damage during and after spaceflight and to compare the results against bed rest with 6 degrees head-down tilt. We measured the urinary excretion of the F(2) isoprostane, 8-iso-prostaglandin (PG) F(2alpha), and 8-oxo-7,8-dihydro-2 deoxyguanosine (8-OH DG) before, during, and after long-duration spaceflight (4-9 mo) on the Russian space station MIR, short-duration spaceflight on the shuttle, and 17 days of bed rest. Sample collections on MIR were obtained between 88 and 186 days in orbit. 8-iso-PGF(2alpha) and 8-OH DG are markers for oxidative damage to membrane lipids and DNA, respectively. Data are mean +/- SE. On MIR, isoprostane levels were decreased inflight (96. 9 +/- 11.6 vs. 76.7 +/- 14.9 ng. kg(-1). day(-1), P < 0.05, n = 6) due to decreased dietary intake secondary to impaired thermoregulation. Isoprostane excretion was increased postflight (245.7 +/- 55.8 ng. kg(-1). day(-1), P < 0.01). 8-OH DG excretion was unchanged with spaceflight and increased postflight (269 +/- 84 vs 442 +/- 180 ng. kg(-1). day(-1), P < 0.05). On the shuttle, 8-OH DG excretion was unchanged in- and postflight, but 8-iso-PGF(2alpha) excretion was decreased inflight (15.6 +/- 4.3 vs 8.0 +/- 2.7 ng. kg(-1). day(-1), P < 0.05). No changes were found with bed rest, but 8-iso-PGF(2alpha) was increased during the recovery phase (48.9 +/- 23.0 vs 65.4 +/- 28.3 ng. kg(-1). day(-1), P < 0.05). The changes in isoprostane production were attributed to decreased production of oxygen radicals from the electron transport chain due to the reduced energy intake inflight. The postflight increases in the excretion of the products of oxidative damage were attributed to a combination of an increase in metabolic activity and the loss of some host antioxidant defenses inflight. We conclude that 1) oxidative damage was decreased inflight, and 2) oxidative damage was increased postflight.

Mir Project↗

Signal Processing of Multiplexed Optical PWM Signals for Sensor Arrays in Nuclear Environments

Safe and effective generation of terrestrial nuclear power greatly benefits from the actionable data provided by the array of sensors located throughout a plant to provide a holistic online indication of reactor operation. This array includes sensors for monitoring coolant flow and pressure, temperature and heat transfer, radiation levels, structure health monitoring, and other critical parameters for reactor operation. While sensors capable of measuring these parameters have been developed, the electronics used in the pre-amplification and analog-to-digital conversion of the small signals they produce are extremely sensitive and susceptible to damage by high-temperatures and radiation environments nuclear reactors encounter while generating power. The small signals from sensors in nuclear power plants (NPPs) are transmitted over long cable runs which introduce dispersion artifacts into the signals of interest as well as electromagnetic interference (EMI) from lighting fixtures, pumps, mains electricity, and other equipment. To overcome these challenges, a front-end digitization (FREND) platform has been developed to use radiation-tolerant electronics to multiplex, amplify, and optically encode signals from an array of sensors for transmission over an optical fiber to mitigate dispersion and EMI artifacts from long runs of electrical cabling. To recover the optically transmitted data, a signal processing scheme based on 1-dimensional template matching to an indexing channel is described herein and demonstrated to have an effective bit-depth of 9.2 bits (1%). This scheme has been validated in proof-of-concept, non-nuclear testing and preliminary experimental results show good agreement between the measured optical output and and sensor input signals. The FREND system represents a low-loss data link between sensors in nuclear environments and data acquisition hardware which is aimed at improving the signal-to-noise ratio of the data acquired from these sensors to provide better information to operators and researchers.

Sweeney, Dan↗

Study And Comparison Of Silver Mirrors Deposited On Different Substrates By Electron-Beam Gun Method

Choosing the right substrate is one of the important factors for improving quality parameters of thin films such as adhesion between layers and substrates. The selected substrate should have proper physical and chemical compatibility with deposited thin film. In this paper, we have been investigated four different types of high reflective laser mirrors that were produced in similar conditions on four different kinds of substrates including copper, stainless steel, brass, and nickel. We used electron-beam gun method for deposition of silver layers. At the end we compared theoretical results with practical results that were yielded by laser damage threshold test. It was shown that brass is the best choice for silver metal mirrors as a substrate.

36 MATERIALS SCIENCE↗

Thermal spike effect in sputtering of porous germanium to form surface pattern by high energy heavy ions irradiation

Germanium exhibits a remarkable effect when subjected to high energy heavy ions irradiation. A synergic effect of high electronic energy loss (S{sub e} = 16.4 keV nm{sup −1}) and nuclear energy loss (S{sub n} = 0.1 keV nm{sup −1}) of 100 MeV Ag ions irradiation in Ge is presented. The results show that crystalline Ge is insensitive to the ionizing part of energy loss whereas thermal spike generated in the damaged Ge leads to the formation of porous structure. Further, an unusual high sputtering of the porous structure opens up the sub-surface voids to show the surface pattern. We explore the role of electron and phonon confinement to explain this effect.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗