Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electrical distribution systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Photovoltaic solar system connected to the electric power grid operating as active power generator and reactive power compensator

In the case of photovoltaic (PV) systems acting as distributed generation (DG) systems, the DC energy that is produced is fed to the grid through the power-conditioning unit (inverter). The majority of contemporary inverters used in DG systems are current source inverters (CSI) operating at unity power factor. If, however, we assume that voltage source inverters (VSI) can replace CSIs, we can generate reactive power proportionally to the remaining unused capacity at any given time. According to the theory of instantaneous power, the inverter reactive power can be regulated by changing the amplitude of its output voltage. In addition, the inverter active power can be adjusted by modifying the phase angle of its output voltage. Based on such theory, both the active power supply and the reactive power compensation (RPC) can be carried out simultaneously. When the insolation is weak or the PV modules are inoperative at night, the RPC feature of a PV system can still be used to improve the inverter utilisation factor. Some MATLAB simulation results are included here to show the feasibility of the method. (author)

14 SOLAR ENERGY↗

Entry, Descent, and Landing Analysis of Low Mass Martian Probe for Surface Climate Network

Aeolus is a mission to provide the first direct measurements of Martian atmospheric wind speeds and correlate them with thermal and compositional data to bring together a complete systematic description for the global energy balance and climate cycles of Mars. Objective A of the Mars Exploration Program Analysis Group (MEPAG) Goal II cites a Science Investigation Area to develop a network of surface landers to provide global, diurnal and synoptic coverage of the near-surface environment to characterize present Mars climate [1]. Aeolus will characterize the present Martian global climate system via an orbiter element and a novel surface network element. A series of low mass, low power probes will be distributed across the Martian surface and measure pressure, sky opacity, temperature, wind speed, water vapor and other trace gases. Low mass and power electrical systems designed to operate in extreme cold and daily thermal cycling for one Martian year could facilitate lower cost, Class-D science probes. Aeolus is targeting a total per-probe mass of <5 kg. Recent advances in nanofabrication of chip-scale sensors that are highly robust to temperature and shock, combined with a novel packaging concept (the deployable sensor probe [2]) originally developed by the Aerospace Corp., for the first time enables a Mars surface climate sensor network. These probes are folded flat during transit to Mars and automatically deploy into the final reentry configuration once released from the orbiter. The capability to fold for stowage significantly increases the probe quantity carried by the orbiter.

EDL↗

Advanced Platform for Development and Evaluation of Grid Interconnection Systems Using Hardware-in-the-Loop: Part III – Grid Interconnection System Evaluator

This paper describes a Grid Interconnection System Evaluator (GISE) that leverages hardware-in-the-loop (HIL) simulation techniques to rapidly evaluate the grid interconnection standard conformance of an ICS according to the procedures in IEEE Std 1547.1. The architecture and test sequencing of this evaluation tool, along with a set of representative ICS test results from three different photovoltaic (PV) inverters, are presented. The GISE adds to the National Renewable Energy Laboratory's (NREL) evaluation platform that now allows for rapid development of ICS control algorithms using controller HIL (CHIL) techniques, the ability to test the dc input characteristics of PV-based ICSs through the use of a PV simulator capable of simulating real-world dynamics using power HIL (PHIL), and evaluation of ICS grid interconnection conformance.

14 SOLAR ENERGY↗

An integrated approach to optimizing concentration shock wave electrodialysis using 2D multicell simulation and response surface models

Shock wave electrodialysis (SWED) is a highly promising technique for energy-efficient ion separation in the context of a circular economy. This paper presents a approach way of modeling and improving SWED using a two-dimensional multicell model combined with the COMSOL program and response surface methodology. The model integrates the Nernst-Planck equation, Darcy's law, and first-order electroosmosis to examine the local concentration, flux of ionic species, distribution of current, and velocity of flow in SWED cells under various operating conditions. We first illustrate the clear depiction of concentration, velocity, and electric potential distribution through contours which aids in identifying optimal operating conditions and designing scalable SWED systems. The results emphasize the significance of surface charge density and voltage in influencing the features of shock waves for obtaining effective ion separation while optimizing energy consumption and improving current efficiency by controlling the retention time of feed flow. Here, this study defines two crucial characteristics of shock waves, namely the length of the flat depletion zone of a fully developed shock wave (shock wave height) and the distance of shock wave propagation (shock wave length). These properties significantly impact separation performance, as determined by the simulation results. Additionally, the response surface methodology is incorporated with the COMSOL models to develop predictive models and graph responses, enabling a more comprehensive understanding of the interactions between parameters and performance indicators, such as removal ratio, energy consumption, and water recovery. Finally, this work suggests design tactics for expanding SWED processes and outlines potential areas for further research. This research provides valuable insights into the prospective applications, design optimization, and scalability of SWED in the field of electrokinetic separation technologies for green chemistry and a circular economy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Microscale plasma actuators for improved thrust density

We present a study of the dielectric barrier discharge (DBD) plasma actuators for microscale applications. Traditional macroscale DBD actuators suffer from relatively small actuation effect as characterized by small induced force density and resulting flow velocity. As a remedy we propose microscale plasma actuators that may induce orders of magnitude higher force density. We study the physics of such actuation using a multiscale ionized gas flow code based on the high-fidelity finite-element procedure. First, a two-dimensional volume discharge with nitrogen as a working gas is investigated using a first-principles approach solving coupled system of hydrodynamic plasma equations and Poisson equation for ion density, electron density, and electric field distribution. The quasi-neutral plasma and the sheath regions are identified. As the gap between electrodes is reduced, the sheath structure dominates the plasma region. Second, we simulate a first generation plasma micropump. We solve multiscale plasma-gas interaction inside a two-dimensional cross section of the microscale pump geometry. The result shows that a reasonable mass flow rate can be pumped using a set of small active electrodes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Occupant-Centric Demand Response for Thermostatically-Controlled Home Loads

Efficiently managing energy usage to balance supply and demand on the electric grid is crucial, especially with the widespread deployment of distributed variable renewable electricity generation. This paper introduces two duty-cycle control methods for heating systems, adjusting thermostat setpoints to limit and shift electricity demand. The control approaches employ innovative techniques, such as adaptive duty cycling, to prioritize household thermal comfort while reducing peak demand. These control methods can respond to signals from the electric grid, including demand targets and time-of-use tariffs, and were tested physically on an electric furnace and heat pump in a test home during winter conditions in 2021 and 2022. The results are given as average demand reductions and energy use impacts with respect to the average indoor-outdoor temperature difference during the control period. For heat pumps, demand limiting control reduced power by 18.5% and 23.3% for indoor-outdoor temperature differences of 30°F and 40°F. Preheating-based demand shifting achieved reductions of 34.8% and 33.2% for the same temperature differences. Electric furnace tests showed demand reductions of 33.8% and 25.3% for demand limiting, and 56.1% and 45.7% for preheating-based demand shifting. These findings highlight the potential for innovative control methods to enhance grid efficiency and reduce energy consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Maui Energy Storage Study

This report investigates strategies to mitigate anticipated wind energy curtailment on Maui, with a focus on grid-level energy storage technology. The study team developed an hourly production cost model of the Maui Electric Company (MECO) system, with an expected 72 MW of wind generation and 15 MW of distributed photovoltaic (PV) generation in 2015, and used this model to investigate strategies that mitigate wind energy curtailment. It was found that storage projects can reduce both wind curtailment and the annual cost of producing power, and can do so in a cost-effective manner. Most of the savings achieved in these scenarios are not from replacing constant-cost diesel-fired generation with wind generation. Instead, the savings are achieved by the more efficient operation of the conventional units of the system. Using additional storage for spinning reserve enables the system to decrease the amount of spinning reserve provided by single-cycle units. This decreases the amount of generation from these units, which are often operated at their least efficient point (at minimum load). At the same time, the amount of spinning reserve from the efficient combined-cycle units also decreases, allowing these units to operate at higher, more efficient levels.

Ellison, James↗

Keyless Infrastructure Security Solution (KISS): VOLTTRON™ KSI ® Blockchain Design and Specification

This document provides the technical design specifications that are required for Keyless Infrastructure Security Solution (KISS) development, including, definitions and roles of the new KISS-related products—GridAware and LinkLite—an overview of the DNP3 communications the VOLTTRON™ DNP3 agent is using for distribution control, data flow, historian processing, setup, and installation. These technical specifications provide step-by-step instructions for configuration, implementation, and deployment of the KISS subsystem, docket creation, and verification using the GridAware dashboard. Based on this document and the KISS specification requirements and device risk assessment documents, KISS will be developed by integrating keyless signature infrastructure (KSI) blockchain to increase the cybersecurity, integrity, and trustworthiness of critical energy delivery systems (EDSs). The KISS architecture consists of a VOLTTRON™ agent-based distribution control system platform and GridAware (KSI blockchain capability) for secure energy exchanges in a decentralized electrical network.

42 ENGINEERING↗

Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available.

08 HYDROGEN↗

​​Hydrogen Transportation and Distributed Energy Systems Seismic Risk Assessment for Cascadia Subduction Zone Airport Facilities​

Portland International Airport in Oregon is exploring operating a fleet of 28 fuel cell electric buses to support airport operations and possibly provide backup power during outages. In this report, we evaluate the risk of hydrogen deployment at an airport considering the potential for seismic activity. We present a seismic risk assessment for pressurized piping for a generic hydrogen refueling station at the airport. Only pressurized piping was considered in the risk analysis because of its vulnerability and availability of fragility information unlike the other components. Seismic capacity of other components should be included as more information becomes available. To characterize the seismic hazard, we considered the initiating event frequency of a Cascadia Subduction Zone earthquake event based on data from the literature. Seismic stressors that translate to the site from an earthquake event are expressed as peak ground acceleration. Site disturbance is characterized as a function of soil conditions, represented by different shear wave velocity values, which affect how seismic waves propagate and impact structures. Pipe fragility curves as a function of seismic capacity were used to correlate ground acceleration and failure probability. These fragility characteristics were combined with site-specific soil conditions to calculate the probability of pipe rupture during a seismic event. It should be noted that multiple simultaneous failures due to an earthquake event as a common cause are not considered. Some epistemic uncertainties such as self-exciting shocks, aftershocks, and the time variant nature of the ground motion are not considered either.

08 HYDROGEN↗

Distributed Wind Certification Best Practices Guideline: January 16, 2023-January 15, 2026

This Distributed Wind (DW) Certification Best Practices Guideline describes the typical approach for certification of distributed wind turbines above and below 150 kilowatts (kW) in size based on the conformity assessment requirements in the United States. The purpose of the guideline is to clarify and consistently describe the complex path to certification for various systems and components. This is done via clarification of both the required turbine type certification elements, as well as third-party electrical safety listing of turbine system components and subassemblies.

17 WIND ENERGY↗

Design considerations for large space electric power systems

As power levels of spacecraft rise to the 50 to 100 kW range, it becomes apparent that low voltage (28 V) dc power distribution and management systems will not operate efficiently at these higher power levels. The concept of transforming a solar array voltage at 150 V dc into a 1000 V ac distribution system operating at 20 kHz is examined. The transformation is accomplished with series-resonant inverter by using a rotary transformer to isolate the solar array from the spacecraft. The power can then be distributed in any desired method such as three phase delta to delta. The distribution voltage can be easily transformed to any desired load voltage and operating frequency. The reasons for the voltage limitations on the solar array due to plasma interactions and the many advantages of a high voltage, high frequency at distribution system are discussed.

Renz, D. D.↗

Simulation test beds for the space station electrical power system

NASA Lewis Research Center and its prime contractor are responsible for developing the electrical power system on the space station. The power system will be controlled by a network of distributed processors. Control software will be verified, validated, and tested in hardware and software test beds. Current plans for the software test bed involve using real time and nonreal time simulations of the power system. This paper will discuss the general simulation objectives and configurations, control architecture, interfaces between simulator and controls, types of tests, and facility configurations.

Sadler, Gerald G.↗

Hubble Space Telescope electrical power system simulation breadboard

The components and operation of the Hubble Space Telescope (HST) electrical power system (EPS) breadboard are described. The HST EPS breadboard consists of: (1) the power distribution breadboard, (2) the batteries, (3) the solar array simulators, (4) the load banks, (5) the charge current control hardware, and (6) a control computer; the functions of each of these elements are discussed. The HST EPS has been used to simulate changes in charge level, charge control schemes, and beta angle, failed cells, batteries, solar panel assemblies (SPAs), beginning of life SPAs, and end of life SPAs, and temperature differences. The test data reveal that the HST EPS is capable of operating over a wide range of conditions.

Bush, John R., Jr.↗

Simulation test beds for the Space Station electrical power system

NASA Lewis Research Center and its prime contractor are respnsible for developing the electrical power system on the Space Station. The power system will be controlled by a network of distributed processors. Control software will be verified, validated, and tested in hardware and software test beds. Current plans for the software test bed involve using real time and nonreal time simulations of the power system. This paper will discuss the general simulation objectives and configurations, control architecture, interfaces between simulator and controls, types of tests, and facility configurations.

Sadler, Gerald G.↗

Remote sensing of the ring current using energetic neutral atoms

Energetic neutral atom images of the storm-time ring current obtained from the ISEE-1 spacecraft provide information for a 'zero-order' global model of the energetic ion distribution. With the assumption of isotropic pressure and magnetostatic, nonconvective pressure balance, the global system of electrical currents driven by the ion pressure can be calculated using Euler potentials for the divergenceless current density. Radial pressure gradients drive azimuthal currents, and azimuthal pressure gradients drive radial currents. The radial currents cause current lines in the inner magnetosphere to close in the ionosphere, forming a partial ring current. The intensities and locations of these field-aligned currents driven into and out of the ionosphere resemble those of the observed Region 2 current system, but not all observed properties of the Region 2 system are reproduced by the zero-order model.

Roelof, Edmond C.↗

Development and testing of a source subsystem for the supporting development PMAD DC test bed

The supporting Development Power Management and Distribution (PMAD) DC Test Bed is described. Its benefits to the Space Station Freedom Electrical Power System design are discussed along with a short description of how the PMAD DC Test Bed was systematically integrated. The Source Subsystem of the PMAD DC Test Bed consisting of a Sequential Shunt Unit (SSU) and a Battery Charge/Discharge Unit (BCDU) is introduced. The SSU is described in detail and component level test data is presented. Next, the BCDU's operation and design is given along with component level test data. The Source Subsystem is then presented and early data given to demonstrate an effective subsystem design.

Button, Robert M.↗

Development and testing of a source subsystem for the supporting development PMAD DC test bed

The supporting Development Power Management and Distribution (PMAD) DC test bed is described. Its benefits to the Space Station Freedom Electrical Power System design are discussed along with a short description of how the PMAD DC test bed was systematically integrated. The source subsystem of the PMAD DC test bed, consisting of a Sequential Shunt Unit (SSU) and a Battery Charge/Discharge Unit (BCDU), is introduced. The SSU is described in detail and component-level test data is presented. Next, the BCDU's operation and design are given along with component-level test data. The Source Subsystem is then presented and early data given to demonstrate an effective subsystem design.

Button, Robert M.↗