Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “electric load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

More / All Electric Vertical Take-Off and Landing (VTOL) Vehicle Sensitivities to Propulsion and Power Performance

Battery power and energy density are important parameters for the emerging concepts for more / all-electric vehicles. Electric propulsion and power system performance is also important. To better understand how electric propulsion and power systems component performance influences overall vehicle design, a sensitivity assessment was performed noting changes in vehicle gross weight and energy usage. Updated versions of the Revolutionary Vertical lift Technology (RVLT) Project vertical take-off and landing (VTOL) urban air mobility (UAM) reference vehicles and missions were used. NASA electric vehicle studies are discussed which were used to help select the range of electric propulsion and power system performance parameters used in this assessment. Thermal management systems (TMS) considerations are also important; new and innovative power management and distribution systems can reduce electric system weight and losses, reducing thermal management constraints often imposed by electric systems modest maximum use temperatures. Vehicles with higher disk loadings (smaller rotors) require higher power levels per unit weight for VTOL operations, which make them more sensitive to electric system weights and efficiencies. Battery, all-electric vehicles show different sensitivities to component performance than turboelectric or hybrids systems. Battery, all-electric propulsion systems may increase vehicle weight and size, but still results in lower mission energy usage than their hydrocarbon-fueled versions. Significant vehicle weight growth to electric propulsion and power system power-to-weight reductions also occurs at different levels among the various concepts. From these results, one can more readily identify required component performance levels, potential component choices or, research and development paths.

Electric Propulsion Systems (Aircraft)↗

More / All Electric Vertical Take-Off and Landing (VTOL) Vehicle Sensitivities to Propulsion and Power Performance

Battery power and energy density are important parameters for the emerging concepts for more / all-electric vehicles. Electric propulsion and power system performance is also important. To better understand how electric propulsion and power systems component performance influences overall vehicle design, a sensitivity assessment was performed noting changes in vehicle gross weight and energy usage. Updated versions of the Revolutionary Vertical lift Technology (RVLT) Project vertical take-off and landing (VTOL) urban air mobility (UAM) reference vehicles and missions were used. NASA electric vehicle studies are discussed which were used to help select the range of electric propulsion and power system performance parameters used in this assessment. Thermal management systems (TMS) considerations are also important; new and innovative power management and distribution systems can reduce electric system weight and losses, reducing thermal management constraints often imposed by electric systems modest maximum use temperatures. Vehicles with higher disk loadings (smaller rotors) require higher power levels per unit weight for VTOL operations, which make them more sensitive to electric system weights and efficiencies. Battery, all-electric vehicles show different sensitivities to component performance than turboelectric or hybrids systems. Battery, all-electric propulsion systems may increase vehicle weight and size, but still results in lower mission energy usage than their hydrocarbon-fueled versions. Significant vehicle weight growth to electric propulsion and power system power-to-weight reductions also occurs at different levels among the various concepts. From these results, one can more readily identify required component performance levels, potential component choices or, research and development paths.

electric propulsion systems (aircraft) mission ana↗

A Framework to Analyze the Requirements of a Multiport Megawatt-Level Charging Station for Heavy-Duty Electric Vehicles

Widespread adoption of heavy-duty (HD) electric vehicles (EVs) will soon necessitate the use of megawatt (MW)-scale charging stations to charge high-capacity HD EV battery packs. Such a station design needs to anticipate possible station traffic, average and peak power demand, and charging/wait time targets to improve throughput and maximize revenue-generating operations. High-power direct current charging is an attractive candidate for MW-scale charging stations at the time of this study, but there are no precedents for such a station design for HD vehicles. We present a modeling and data analysis framework to elucidate the dependencies of a MW-scale station operation on vehicle traffic data and station design parameters and how that impacts vehicle electrification. This framework integrates an agent-based charging station model with vehicle schedules obtained through real-world vehicle telemetry data analysis to explore the station design and operation space. A case study applies this framework to a Class 8 vehicle telemetry dataset and uses Monte Carlo simulations to explore various design considerations for MW-scale charging stations and EV battery technologies. The results show a direct correlation between optimal charging station placement and major traffic corridors such as cities with ports, e.g., Los Angeles and Oakland. Corresponding parametric sweeps reveal that while good quality of service can be achieved with a mix of 1.2-megawatt and 100-kilowatt chargers, the resultant fast charging time of 35–40 min will need higher charging power to reach parity with refueling times.

33 ADVANCED PROPULSION SYSTEMS↗

Commercial Building Loads Providing Ancillary Services in PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

54 ENVIRONMENTAL SCIENCES↗

Commercial building loads providing ancillary services In PJM

The adoption of low carbon energy technologies such as variable renewable energy and electric vehicles, coupled with the efficacy of energy efficiency to reduce traditional base load has increased the uncertainty inherent in the net load shape. Handling this variability with slower, traditional resources leads to inefficient system dispatch, and in some cases may compromise reliability. Grid operators are looking to future energy technologies, such as automated demand response (DR), to provide capacity-based reliability services as the need for these services increase. While DR resources are expected to have the flexibility characteristics operators are looking for, demonstrations are necessary to build confidence in their capabilities. Additionally, building owners are uncertain of the monetary value and operational burden of providing these services. To address this, the present study demonstrates the ability of demand response resources providing two ancillary services in the PJM territory, synchronous reserve and regulation, using an OpenADR 2.0b signaling architecture. The loads under control include HVAC and lighting at a big box retail store and variable frequency fan loads. The study examines performance characteristics of the resource: the speed of response, communications latencies in the architecture, and accuracy of response. It also examines the frequency and duration of events and the value in the marketplace which can be used to examine if the opportunity is sufficient to entice building owners to participate.

MacDonald, Jason↗

Transactive Control of Commercial Buildings for Demand Response

Transactive control is a type of distributed control strategy that uses market mechanism to engage self-interested responsive loads to achieve power balance in the electrical power grid. In this paper, we propose a transactive control approach of commercial building Heating, Ventilation, and Air- Conditioning (HVAC) systems for demand response. We first describe the system models, and identify their model parameters using data collected from Systems Engineering Building (SEB) located on our Pacific Northwest National Laboratory (PNNL) campus. We next present a transactive control market structure for commercial building HVAC system, and describe its agent bidding and market clearing strategies. Several case studies are performed in a simulation environment using Building Control Virtual Test Bed (BCVTB) and calibrated SEB EnergyPlus model. We show that the proposed transactive control approach is very effective at peak clipping, load shifting, and strategic conservation for commercial building HVAC systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Regional Medium-Term Hourly Electricity Demand Forecasting Based on LSTM

This paper aims to forecast high-resolution (hourly) aggregated load for a certain region in the medium term (a few days to over a year). One region is defined as some places with similar climate characteristics because the climate influences people's daily lifestyles and hence the electric usage. We decom- pose the electric usage records into two parts: base load and seasonal load. Considering both temperature and time factors, different deep learning methods are adopted to characterize them. The first goal of our approach is to predict the peak load which is critical for power system planning. Furthermore, our proposed forecast method can provide the depiction of the hourly load profile to provide customized load curves for high- level real-time applications. The proposed method is tested on real-world historical data collected by CAISO, BPA, and PACW. The experimental results show that trained by three years of data, our method could reduce the prediction error for one-year lead hourly load below 5% MAPE, and predict the occurrence of the peak load for next year in CAISO with an error within three days. Furthermore, as a byproduct, an interesting observation on the impact of COVID-19 on human life was made and discussed based on these case studies.

deep learning↗

Regional Medium-Term Hourly Electricity Demand Forecasting Based on LSTM

This paper aims to forecast high-resolution (hourly) aggregated load for a certain region in the medium term (a few days to over a year). One region is defined as some places with similar climate characteristics because the climate influences people's daily lifestyles and hence the electric usage. We decompose the electric usage records into two parts: base load and seasonal load. Considering both temperature and time factors, different deep-learning methods are adopted to characterize them. The first goal of our approach is to predict the peak load which is critical for power system planning. Furthermore, our proposed forecast method can provide the depiction of the hourly load profile to provide customized load curves for high-level real-time applications. The proposed method is tested on real-world historical data collected by CAISO, BPA, and PACW. The experimental results show that trained by three years of data, our method could reduce the prediction error for a one-year lead hourly load below $5\%$ MAPE, and predict the occurrence of the peak load for next year in CAISO with an error within three days. Furthermore, as a byproduct, an interesting observation on the impact of COVID-19 on human life was made and discussed based on these case studies.

deep learning↗

Mercury Binding Sites in Thiol-Functionalized Mesostructured Silica

Thiol-functionalized mesostructured silica with anhydrous compositions of (SiO{sub 2}){sub 1-x}(LSiO{sub 1.5}){sub x}, where L is a mercaptopropyl group and x is the fraction of functionalized framework silicon centers, are effective trapping agents for the removal of mercuric(II) ions from water. In the present work, we investigate the mercury-binding mechanism for representative thiol-functionalized mesostructures by atomic pair distribution function (PDF) analysis of synchrotron X-ray powder diffraction data and by Raman spectroscopy. The mesostructures with wormhole framework structures and compositions corresponding to x = 0.30 and 0.50 were prepared by direct assembly methods in the presence of a structure-directing amine porogen. PDF analyses of five mercury-loaded compositions with Hg/S ratios of 0.50-1.30 provided evidence for the bridging of thiolate sulfur atoms to two metal ion centers and the formation of chain structures on the pore surfaces. We find no evidence for Hg-O bonds and can rule out oxygen coordination of the mercury at greater than the 10% level. The relative intensities of the PDF peaks corresponding to Hg-S and Hg-Hg atomic pairs indicate that the mercury centers cluster on the functionalized surfaces by virtue of thiolate bridging, regardless of the overall mercury loading. However, the Raman results indicate that the complexation of mercury centers by thiolate depends on the mercury loading. At low mercury loadings (Hg/S {le} 0.5), the dominant species is an electrically neutral complex in which mercury most likely is tetrahedrally coordinated to bridging thiolate ligands, as in Hg(SBu{sup t}){sub 2}. At higher loadings (Hg/S 1.0-1.3), mercury complex cations predominate, as evidenced by the presence of charge-balancing anions (nitrate) on the surface. This cationic form of bound mercury is assigned a linear coordination to two bridging thiolate ligands.

43 PARTICLE ACCELERATORS↗

Load-Shifting Strategies for Cost-Effective Emission Reductions at Wastewater Facilities

Significant hourly variation in the carbon intensity of electricity supplied to wastewater facilities introduces an opportunity to lower emissions by shifting the timing of their energy demand. This shift could be accomplished by storing wastewater, biogas from sludge digestion, or electricity from on-site biogas generation. However, the life cycle emissions and cost implications of these options are not clear. Here, we present a multiobjective optimization framework for comparing cost- and emission-minimizing load-shifting strategies at a California case study facility with a relatively low carbon intensity grid and high spread in peak and off-peak electricity prices. We evaluate cost and emission trade-offs from the optimal flexible operation of both existing infrastructure and optimally sized energy flexibility upgrades. We estimate energy-related emission reductions of up to 9.0% with flexible operation of existing infrastructure and up to 16.8% with optimally sized storage upgrades. Only a fraction of these potential savings are realized under actual industrial energy tariffs and the EPA’s recommended social cost of carbon. Energy flexibility may hold promise as a short-term emission-saving solution for the wastewater sector, but the extent of savings is heavily dependent on the cost of carbon, electricity tariffs, and emission intensity of the regional electricity grid.

climate↗

Search for a ''3.5-eV isomer'' in {sup 229}Th in a hollow-cathode electric discharge

A hollow-cathode electric discharge, a well-established source in optical spectroscopy, was used to populate the ''3.5-eV isomer'' in {sup 229}Th with use of nuclear excitation by electron transition (NEET). The radiochemically purest {sup 229}Th sample was loaded into the hollow cathode in which the electric discharge excited the {sup 229}Th to atomic states some of which could be expected to lie close to the excitation energy of the sought isomer. Although there remain some uncertainties, our experiments indicate that the isomer was populated by NEET and its {alpha} decay observed after switching off the electric discharge with a corresponding isomer half-life 1 min < or approx. T{sub 1/2}{sup m} < or approx. 3 min. From the present NEET condition, the isomer appears to lie between 3 eV and 7 eV. The probability of the isomer population by NEET is discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ABSORPTION CHILLER AND STRATIFIED CHILLED-WATER STORAGE TANK CONFIGURATIONS FOR COUPLING TO A SMALL MODULAR REACTOR

Power maneuvers stemming from time-varying loads imposed on nuclear reactors from diurnal changes in demand and renewable intermittency can be detrimental to the life of the reactor. Temperature swings during power maneuvers result in thermal and mechanical stresses in fuel elements and other reactor components. Thermal Energy Storage (TES) reservoirs can be coupled to reactors to absorb these grid instabilities. Previous work has shown chilled-water storage can help shift cooling loads that contribute to the daily peak electric demand from on-peak to off-peak hours. The objective of this work is to evaluate a stratified chilled-water storage tank as a potential TES reservoir for a Small Modular Reactor (SMR) using absorption chillers for chilled-water production. Simulation results reveal absorption chiller performance is hindered when receiving steam from a tap on the low-pressure turbine. A better configuration involves integrating the absorption chillers into a flash vessel system that is thermally coupled to a sensible heat storage system. The sensible heat storage system maintains reactor thermal output at 100% and matches turbine output with demand while producing enough steam to power four large absorption chillers to charge a stratified chilled-water storage tank, which is used to offset cooling loads in an adjacent facility.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Magnetoelectric effects in multiferroic fibrous composite with imperfect interface

This paper investigates the magnetoelectroelastic responses of multiferroic fibrous composites with imperfectly bonded interface under longitudinal shear. The proposed imperfect interface model is a natural generalization of the shear lag (or the spring layer) model. By virtue of the complex variable method, we first consider the case where an isolated circular multiferroic fiber is imperfectly bonded to an infinite multiferroic matrix. Very concise expressions for the complex field potentials characterizing the magnetoelectroelastic fields inside and outside the circular fiber are obtained when the matrix is subjected to the remote uniform magnetoelectroelastic loading. The Mori-Tanaka mean-field method is then employed to derive the effective moduli of the multiferroic fibrous composite made of randomly distributed fibers reinforced to the matrix. Particularly we demonstrate that the interfacial imperfection in elasticity, electricity, and magnetism will always cause a significant reduction in the magnetoelectric coefficient of the BaTiO{sub 3}-CoFe{sub 2}O{sub 4} fibrous composite.

36 MATERIALS SCIENCE↗

Considerations for Short-Term Load Forecasting of Morocco

There are many factors that determine how demand for electricity may change over time. The analysis described in this report is focused on using auto-regressive models and neural networks to examine load-forecasting techniques for the next 24 hours.

54 ENVIRONMENTAL SCIENCES↗

Analysis of Residential Time-of-Use Utility Rate Structures and Economic Implications for Thermal Energy Storage

Thermal energy storage (TES) is an increasingly popular tool to level out the daily electrical demand and add stability to the electrical grid as more intermittent renewable energy sources are installed. TES systems can locally decouple high thermal loads from the operation of a heat pump or reduce the electrical energy demand of the heat pump by providing a more favorable temperature gradient. In addition, many policy makers and utility providers have introduced time-of-use (TOU) rate schedules for residential customers to better reflect the price of electricity generation and demand for specific times. TOU rate schedules price grid-provided electricity differently throughout the day depending on the region’s climate, time of year, and electrical production. Large differences between on-peak and off-peak electrical prices may create an economic advantage for a residential customer to install a TES system. In this work, the economic and energy savings are calculated for a modeled 2,400 square foot residential building with water/ice-based TES using a TOU rate structure. The weather data is from Fresno County, CA, ASHRAE climate zone 3B, and a representative residential TOU utility rate structure from Pacific Gas and Electric (PG&E) was used. The results showed that total energy consumption could be reduced by 14.5% with an 87.5% reduction in on-peak energy usage when the TES is installed. The cost of operating this system for space cooling was reduced by nearly 20% using the sample utility rate plan.

Sultan, Sara↗

Renewable Energy Requirements for Future Building Codes: Options for Compliance

As the model energy codes are improved to reach efficiency levels 50 percent greater than current codes, use of on-site renewable energy generation is likely to become a code requirement. This requirement will be needed because traditional mechanisms for code improvement, including envelope, mechanical and lighting, have been pressed to the end of reasonable limits. Research has been conducted to determine the mechanism for implementing this requirement (Kaufman 2011). Kaufmann et al. determined that the most appropriate way to structure an on-site renewable requirement for commercial buildings is to define the requirement in terms of an installed power density per unit of roof area. This provides a mechanism that is suitable for the installation of photovoltaic (PV) systems on future buildings to offset electricity and reduce the total building energy load. Kaufmann et al. suggested that an appropriate maximum for the requirement in the commercial sector would be 4 W/ft 2 of roof area or 0.5 W/ft 2 of conditioned floor area. As with all code requirements, there must be an alternative compliance path for buildings that may not reasonably meet the renewables requirement. This might include conditions like shading (which makes rooftop PV arrays less effective), unusual architecture, undesirable roof pitch, unsuitable building orientation, or other issues. In the short term, alternative compliance paths including high performance mechanical equipment, dramatic envelope changes, or controls changes may be feasible. These options may be less expensive than many renewable systems, which will require careful balance of energy measures when setting the code requirement levels. As the stringency of the code continues to increase however, efficiency trade-offs will be maximized, requiring alternative compliance options to be focused solely on renewable electricity trade-offs or equivalent programs. One alternate compliance path includes purchase of Renewable Energy Credits (RECs). Each REC represents a specified amount of renewable electricity production and provides an offset of environmental externalities associated with non-renewable electricity production. The purpose of this paper is to explore the possible issues with RECs and comparable alternative compliance options. Existing codes have been examined to determine energy equivalence between the energy generation requirement and the RECs alternative over the life of the building. The price equivalence of the requirement and the alternative are determined to consider the economic drivers for a market decision. This research includes case studies that review how the few existing codes have incorporated RECs and some of the issues inherent with REC markets. Section 1 of the report reviews compliance options including RECs, green energy purchase programs, shared solar agreements and leases, and other options. Section 2 provides detailed case studies on codes that include RECs and community based alternative compliance methods. The methods the existing code requirements structure alternative compliance options like RECs are the focus of the case studies. Section 3 explores the possible structure of the renewable energy generation requirement in the context of energy and price equivalence. The price of RECs have shown high variation by market and over time which makes it critical to for code language to be updated frequently for a renewable energy generation requirement or the requirement will not remain price-equivalent over time. Section 4 of the report provides a maximum case estimate for impact to the PV market and the REC market based on the Kaufmann et al. proposed requirement levels. If all new buildings in the commercial sector complied with the requirement to install rooftop PV arrays, nearly 4,700 MW of solar would be installed in 2012, a major increase from EIA estimates of 640 MW of solar generation capacity installed in 2009. The residential sector could contribute roughly an additional 2,300 MW based on the same code requirement levels of 4 W/ft 2 of roof area. Section 5 of the report provides a basic framework for draft code language recommendations based on the analysis of the alternative compliance levels.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Making Microgrids Work

Distributed energy resources including distributed generation and distributed storage are sources of energy located near local loads and can provide a variety of benefits including improved reliability if they are properly operated in the electrical distribution system. Microgrids are systems that have at least one distributed energy resource and associated loads and can form intentional islands in the electrical distribution systems. This paper gives an overview of the microgrid operation. Microgrid testing experiences from different counties was also provided.

14 SOLAR ENERGY↗