Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “data set”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Global radiation damage at 300 and 260 K with dose rates approaching 1 MGy s[superscript -1]

Global radiation damage to 19 thaumatin crystals has been measured using dose rates from 3 to 680 kGy s{sup -1}. At room temperature damage per unit dose appears to be roughly independent of dose rate, suggesting that the timescales for important damage processes are less than {approx}1 s. However, at T = 260 K approximately half of the global damage manifested at dose rates of {approx}10 kGy s{sup -1} can be outrun by collecting data at 680 kGy s{sup -1}. Appreciable sample-to-sample variability in global radiation sensitivity at fixed dose rate is observed. This variability cannot be accounted for by errors in dose calculation, crystal slippage or the size of the data sets in the assay.

59 BASIC BIOLOGICAL SCIENCES↗

Understanding materials microstructure and behavior at the mesoscale

Taking the mesoscale to mean length and time scales at which a material’s behavior is too complex to be understood by construction from the atomistic scale, we focus on three-dimensional characterization and modeling of mesoscale responses of polycrystals to thermal and mechanical loading. Both elastic and plastic internal structural responses are now accessible via high-energy x-ray probes. The combination of diffraction experiments and computed tomography, for example, is yielding new insights into how void formation correlates with microstructural features such as grain boundaries and higher-order junctions. The resulting large, combined data sets allow for validation of micromechanical and thermal simulations. As detectors improve in resolution, quantum efficiency, and speed of readout, data rates and data volumes present computational challenges. Spatial resolutions approach one micrometer, while data sets span a cubic millimeter. Examples are given of applications to tensile deformation of copper, grain growth in nickel and titanium, and fatigue cracks in superalloys.

36 MATERIALS SCIENCE↗

Learning Memento archive routing with Character-based Artificial Neural Networks

This white paper describes a series of tests that were performed to determine if a neural network could learn patterns from a service that maintains a cache of routing decisions for the discovery of version information for discrete web-at-large URLs. Labeled training data was derived from a log file that records the by-archive availability of Memento availability for a given URL. Training data sets were generated from this log file on a by-archive basis (thus making it a binary classification problem). Each training data set consisted of equal numbers of hit and miss URLs, selected at random. The URLs were converted to a normalized numeric representation where each integer in a URL training vector represents a character in that URL. The corresponding label indicates whether or not Mementos were available for that URL in the selected archive. The training data matrix and the label vector became input to a neural network. A number of neural network architectures and network hyperparameters were explored, however the log entries themselves were used as-is, without any feature engineering, beyond the aforementioned normalization.

97 MATHEMATICS AND COMPUTING↗

Standardizing Platinum Dainotti-correlated gamma-ray bursts, and using them with standardized Amati-correlated gamma-ray bursts to constrain cosmological model parameters

ABSTRACT We show that the Platinum gamma-ray burst (GRB) data compilation, probing the redshift range 0.553 ≤ z ≤ 5.0, obeys a cosmological-model-independent three-parameter Fundamental Plane (Dainotti) correlation and so is standardizable. While they probe the largely unexplored z ∼ 2.3–5 part of cosmological redshift space, the GRB cosmological parameter constraints are consistent with, but less precise than, those from a combination of baryon acoustic oscillation (BAO) and Hubble parameter [H(z)] data. In order to increase the precision of GRB-only cosmological constraints, we exclude common GRBs from the larger Amati-correlated A118 data set composed of 118 GRBs and jointly analyse the remaining 101 Amati-correlated GRBs with the 50 Platinum GRBs. This joint 151 GRB data set probes the largely unexplored z ∼ 2.3–8.2 region; the resulting GRB-only cosmological constraints are more restrictive, and consistent with, but less precise than, those from H(z) + BAO data.

79 ASTRONOMY AND ASTROPHYSICS↗

SPARTAN and IMPROVE Comparison Experiment (SPICE) Interim Campaign Report

SPICE (the SPARTAN and IMPROVE Comparison Experiment) aims to obtain and quantify comparisons between aerosol PM 2.5 mass concentration measurements from the University of Oklahoma (OU) Surface Particulate Matter Network (SPARTAN) station and the U.S. Environmental Protection Agency (EPA) Interagency Monitoring of Protected Visual Environments (IMPROVE) station hosted by the U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility at ARM’s Southern Great Plains (SGP) observatory in Oklahoma. Aerosols—both natural and anthropogenic—affect human populations in multiple ways. Much of ARM’s research focuses on how aerosols influence weather and climate through their optical and radiative effects, as well as their impacts on clouds and precipitation. However, aerosols also pose direct risks to humans and other organisms through inhalation, with the severity of health impacts depending on particle size, chemical composition, and duration of exposure. The IMPROVE network was established by the U.S. EPA to monitor air quality, including visible clarity as well as total and chemically speciated aerosol mass concentrations. The ARM SGP site hosts the IMPROVE SOGP station. Separately, the SPARTAN network operates a globally distributed set of stations similar to IMPROVE but with an emphasis on remote deployment and semi-autonomous operation for use beyond the borders of the United States (IMPROVE only operates within the U.S.). The University of Oklahoma operates a SPARTAN station. To establish confidence in the OU SPARTAN instrumentation and measurement protocol relative to the EPA-certified IMPROVE station, the OU SPARTAN station is currently deployed at SGP in close proximity to the IMPROVE SOGP station. The SPICE campaign was envisioned as a contiguous calendar-year effort for 2025 to capture seasonal variation in mass loading as well as composition. However, independent of the SPICE campaign, the SPARTAN network adopted a new filter construction part-way through the year, interrupting our contiguous data set. Thus, to obtain a contiguous data set with a uniform consistent configuration, SPICE desires an extension through 2026.

54 ENVIRONMENTAL SCIENCES↗

Sample manipulation and data assembly for robust microcrystal synchrotron crystallography

With the recent developments in microcrystal handling, synchrotron microdiffraction beamline instrumentation and data analysis, microcrystal crystallography with crystal sizes of less than 10 µm is appealing at synchrotrons. However, challenges remain in sample manipulation and data assembly for robust microcrystal synchrotron crystallography. Here, the development of micro-sized polyimide well-mounts for the manipulation of microcrystals of a few micrometres in size and the implementation of a robust data-analysis method for the assembly of rotational microdiffraction data sets from many microcrystals are described. The method demonstrates that microcrystals may be routinely utilized for the acquisition and assembly of complete data sets from synchrotron microdiffraction beamlines.

59 BASIC BIOLOGICAL SCIENCES↗

TU-FG-201-06: Remote Dosimetric Auditing for Clinical Trials Using EPID Dosimetry: A Pilot Study

Purpose: To perform a pilot study for remote dosimetric credentialing of intensity modulated radiation therapy (IMRT) based clinical trials. The study introduces a novel, time efficient and inexpensive dosimetry audit method for multi-center credentialing. The method employs electronic portal imaging device (EPID) to reconstruct delivered dose inside a virtual flat/cylindrical water phantom. Methods: Five centers, including different accelerator types and treatment planning systems (TPS), were asked to download two CT data sets of a Head and Neck (H&N) and Postprostatectomy (P-P) patients to produce benchmark plans. These were then transferred to virtual flat and cylindrical phantom data sets that were also provided. In-air EPID images of the plans were then acquired, and the data sent to the central site for analysis. At the central site, these were converted to DICOM format, all images were used to reconstruct 2D and 3D dose distributions inside respectively the flat and cylindrical phantoms using inhouse EPID to dose conversion software. 2D dose was calculated for individual fields and 3D dose for the combined fields. The results were compared to corresponding TPS doses. Three gamma criteria were used, 3%3mm-3%/2mm–2%/2mm with a 10% dose threshold, to compare the calculated and prescribed dose. Results: All centers had a high pass rate for the criteria of 3%/3 mm. For 2D dose, the average of centers mean pass rate was 99.6% (SD: 0.3%) and 99.8% (SD: 0.3%) for respectively H&N and PP patients. For 3D dose, 3D gamma was used to compare the model dose with TPS combined dose. The mean pass rate was 97.7% (SD: 2.8%) and 98.3% (SD: 1.6%). Conclusion: Successful performance of the method for the pilot centers establishes the method for dosimetric multi-center credentialing. The results are promising and show a high level of gamma agreement and, the procedure is efficient, consistent and inexpensive. Funding has been provided from Department of Radiation Oncology, TROG Cancer Research and the University of Newcastle. Narges Miri is a recipient of a University of Newcastle postgraduate scholarship.

60 APPLIED LIFE SCIENCES↗

Radiatively important parameters best estimate (RIPBE) value-added product (VAP)

Currently, to calculate radiative heating rate profiles for the Broadband Heating Rate Profile (BBHRP) product, radiatively important parameters (water vapor, ozone, surface albedo, aerosol properties, and cloud properties) from multiple VAPs and datastreams are combined into input text files that are then used to run the RRTM radiative transfer codes. These input parameters have different temporal and spatial scales and are difficult to extract from the text files to be used for other purposes such as running other radiative transfer codes, analyzing results, or error tracking. The purpose of the Radiatively Important Parameters Best Estimate (RIPBE) VAP is to improve this process by creating a clearly identified set of inputs for BBHRP (and other radiation codes) on a uniform vertical and temporal grid. This process will decouple the input/output portion of the BBHRP from the core physics (the RRTM radiative transfer model) and will add error tracking and version information to the input data set. Critical parameters (which must exist for the radiation code to be run) will be designated; for other parameters, climatological or fixed values will be used when the preferred values are missing. This should increase the number of cases for which radiative transfer calculations can be run. In all cases, flags will clearly identify the source for each parameter. RIPBE will serve multiple functions: (1) it will provide a clearly identifiable set of inputs for BBHRP, (2) it will facilitate the use of BBHRP as a retrieval and radiation code development testbed by providing a vehicle for easily extracting and swapping input parameters needed to conduct radiative transfer calculations, and (3) it will be a complement to the Climate Modeling Best Estimate (CMBE) VAP and will provide a significantly expanded set of parameters for model evaluation in a showcase data set form. At the ASR meeting, we will present examples and evaluation of the initial RIPBE dataset at SGP.

54 ENVIRONMENTAL SCIENCES↗

Measurement of the U 235 ( n , f ) prompt fission neutron spectrum from 10 keV to 10 MeV induced by neutrons of energy from 1 MeV to 20 MeV

The characterization of fission-driven nuclear systems primarily relies on calculations of neutron-induced chain reactions, and these calculations require evaluated nuclear data as input. Calculation accuracy heavily depends on input nuclear data evaluation accuracy, and thus high precision on the experimental input to the nuclear data evaluation is essential for fundamental quantities like the energy spectrum of neutrons emitted from neutron-induced fission (i.e., the prompt fission neutron spectrum, PFNS). Despite decades of measurement efforts, prior to the measurements described in this work there were only three literature data sets for the 235 U(n,f) PFNS at incident neutron energies above 1.0 MeV considered reliable for inclusion in nuclear data evaluations and no reliable data sets above 3.0 MeV incident neutron energy. In this work we report on new measurements of the 235 U(n,f) PFNS spanning a grid of 1.0–20.0 MeV in incident neutron energy and 0.01–10.0 MeV in outgoing (PFNS) neutron energy. These measurements were carried out at the Weapons Neutron Research facility at the Los Alamos Neutron Science Center and used a multifoil parallel-plate avalanche counter target with both a Li-glass and a liquid scintillator detector array in separate experiments to span the quoted outgoing neutron energy ranges. The PFNS results are shown in terms of the energy spectra themselves as well as the average PFNS energy $(\langle{E}\rangle)$ and ratios of $\langle{E}\rangle$ at forward and backward angles. Here, the results are compared with literature data and selected nuclear data evaluations. Generally, the data agree with the ENDF/B-VIII.0 evaluation below 5.0-MeV incident neutron energy and more closely with the JEFF-3.3 evaluation above 5.0 MeV, though no evaluations considered for comparison in this work agree with the data across all of the incident and outgoing neutron energies shown, especially in regions where the third-chance fission process becomes available. Additionally, we show a ratio of the present PFNS results for 235 U(n, f) with a recent and highly correlated experiment to measure the 239 Pu(n, f) PFNS at the same experimental facility and with nearly identical equipment and analysis procedures. Many observations reported in this work are the first of their kind and represent significant advancements for knowledge of the 235 U(n, f) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics

Data package for Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon This data is published under a CC0 license. The authors encourage data reuse and request attribution by referencing the below citations for the data packages and associated manuscript. Please cite as: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. GLBRC Soil Yearlong Incubation 13C-SIP-Lipidomics. [Data Set] PNNL DataHub. doi: Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. MSV000097435: GLBRC soil yearlong incubation 13C-SIP-Lipidomics [Data Set] MassIVE. doi:10.25345/C57659T3K Rempfert KR, Bell SL, Kasanke CP, Kyle JE, Hofmockel KS. 2025. Lipids represent a dynamic, yet stable pool of microbially-derived soil carbon. In Prep This data package consists of compound-specific 13C SIP-lipidomics data from a yearlong tracer incubation experiment designed to investigate microbial lipid persistence in switchgrass bioenergy crop soils. In order to explore how lipid structure may modulate the persistence of C in soil lipids, we leveraged soils from two sites (Michigan - sandy texture, Wisconsin - silty texture) operated by the U.S. Department of Energy-funded Great Lakes Bioenergy Research Center (GLBRC). These sites had comparable climates, identical management practices, but contrasting soil textures, allowing us to assess the variability of lipid accrual or degradation in soils as well as provide insight regarding the degree to which edaphic properties may regulate the retention of soil lipids. Untargeted lipidomics analyses were performed to identify 13C-labeled lipids in the soil microbiome after long-term incubation. Soils were supplemented with 100 micrograms glucose per gram dry soil (99 atom % 13C or natural abundance for paired control) and incubated; samples were collected two months and one year after glucose addition. Lipid extracts (MPLEx) were analyzed by LC-MS/MS and identified using LIQUID. Calculation of isotopic enrichment of lipids was performed by targeted approach using TarMet to quantify lipid isotopologues and IsoCorrectoR to correct for natural abundance isotopes. Contents: Data package contents reported here are the first version and contain downstream analysis files for the raw LC-MS mass spectrometry files (.mzXML) deposited at the MassIVE database repository under accession MSV000097435 (80 experimental runs; 5.85 GB) | MassIVE DOI: 10.25345/C57659T3K. Support files include the additional data download 'Read Me' file containing data descriptor information. Reported data download contents are structured for compliance with project data sharing guidelines, community standards initiatives, and sponsor stakeholder policies supporting FAIR data principles. Data processing software, analysis tools, and data workflows are listed below corresponding to the host repository long-term location. Available Data Downloads (0.3 GB): "GLBRC soil yearlong incubation 13C-SIP-Lipidomics_readme.txt" - 'Read Me' data package content file (txt) "GLBRC_DataPackage_analysis files" - Data processing files (Rmd) and saved intermediate data processing outputs (rds, csv, xlsx) "GLBRC_13C_lipidomics_dataset.xlsx" - processed data in tabular format (xlsx) Linked Software: LIQUID LC-MS Analysis Software | 10.5281/zenodo.6459462 Lipid Mini-On Software Tools | 10.5281/zenodo.1492803 pmartR Omics Statistical Software | 10.5281/zenodo.6108667 xcms (v4.3.3) TarMet (v1.1.1) IsoCorrectoR (1.24.0) Funding Acknowledgments: This research was supported by an Early Career Research Program award funded by the U.S. Department of Energy, Office of Science, Office of Biological and Environmental Research (OBER) Genomic Science program under FWP 68292, FWP 07880 and EMSL Exploratory Research Project 51095. A portion of this work was performed in the William R. Wiley Environmental Molecular Sciences Laboratory, a national scientific user facility sponsored by OBER and located at Pacific Northwest National Laboratory (PNNL). PNNL is a multi-program national laboratory operated by Battelle for the DOE under Contract DE-AC05-76RLO1830.

Rempfert, Kaitlin R [Pacific Northwest National La↗

CT effective dose per dose length product using ICRP 103 weighting factors

Purpose: To generate effective dose per unit dose length product (E/DLP) conversion factors incorporating ICRP Publication 103 tissue weighting factors. Methods: Effective doses for CT examinations were obtained using the IMPACT Dosimetry Calculator using all 23 dose data sets that are offered by this spreadsheet. CT examinations were simulated for scans performed along the patient long axis for each dosimetry data set using a 4 cm beam width ranging from the upper thighs to top of the head. Five basic body regions (head, neck, chest, abdomen, and pelvis), as well as combinations of the regions (head/neck, chest/abdomen, abdomen/pelvis, and chest/abdomen/pelvis) and whole body CT scans were investigated. Correction factors were generated that can be applied to convert E/DLP conversion factors based on ICRP 60 data to conversion factors that are valid for ICRP 103 data (i.e., E{sub 103}/E{sub 60}). Results: Use of ICRP 103 weighting factors increase effective doses for head scans by {approx}11%, for chest scans by {approx}20%, and decrease effective doses for pelvis scans by {approx}25%. Current E/DLP conversion factors are estimated to be 2.4 {mu}Sv/mGy cm for head CT examinations and range between 14 and 20 {mu}Sv/mGy cm for body CT examinations. Conclusions: Factors that enable patient CT doses to be adjusted to account for ICRP 103 tissue weighting factors are provided, which result in E/DLP factors that were increased in head and chest CT, reduced in pelvis CT, and showed no marked change in neck and abdomen CT.

60 APPLIED LIFE SCIENCES↗

A More Precise Measurement of the Radius of PSR J0740+6620 Using Updated NICER Data

PSR J0740+6620 is the neutron star with the highest precisely determined mass, inferred from radio observations to be 2.08 ± 0.07 M ⊙ . Measurements of its radius therefore hold promise to constrain the properties of the cold, catalyzed, high-density matter in neutron star cores. Previously, Miller et al. and Riley et al. reported measurements of the radius of PSR J0740+6620 based on Neutron Star Interior Composition Explorer (NICER) observations accumulated through 2020 April 17, and an exploratory analysis utilizing NICER background estimates and a data set accumulated through 2021 December 28 was presented in Salmi et al. Here we report an updated radius measurement, derived by fitting models of X-ray emission from the neutron star surface to NICER data accumulated through 2022 April 21, totaling ~1.1 Ms additional exposure compared to the data set analyzed in Miller et al. and Riley et al., and to data from XMM-Newton observations. We find that the equatorial circumferential radius of PSR J0740+6620 is ${12.92}_{-1.13}^{+2.09}$ km (68% credibility), a fractional uncertainty ~83% the width of that reported in Miller et al., in line with statistical expectations given the additional data. If we were to require the radius to be less than 16 km, as was done in Salmi et al., then our 68% credible region would become $R={12.76}_{-1.02}^{+1.49}$ km, which is close to the headline result of Salmi et al. Our updated measurements, along with other laboratory and astrophysical constraints, imply a slightly softer equation of state than that inferred from our previous measurements.

79 ASTRONOMY AND ASTROPHYSICS↗

Standard Energy Efficiency Data Platform

The SEED platform is expected to be a building energy performance data management tool that provides federal, state and local governments, building owners and operators with an easy, flexible and cost-effective method to collect information about groups of buildings, oversee compliance with energy disclosure laws and demonstrate the economic and environmental benefits of energy efficiency. It will allow users to leverage a local application to manage data disclosure and large data sets without the IT investment of developing custom applications. The first users of SEED will be agencies that need to collect, store, and report/share large data sets generated by benchmarking, energy auditing, retro-commissioning or retrofitting of many buildings. Similarly, building owners and operators will use SEED to manage their own energy data in a common format and centralized location. SEED users will also control the disclosure of their information for compliance requirements, recognition programs such as ENERGY STAR, or data sharing with the Buildings Performance Database and/or other third parties at their discretion.

Cheifetz, D.Magnus↗

Standard Energy Efficiency Data Platform

The SEED platform is expected to be a building energy performance data management tool that provides federal, state and local governments, building owners and operators with an easy, flexible and cost-effective method to collect information about groups of buildings, oversee compliance with energy disclosure laws and demonstrate the economic and environmental benefits of energy efficiency. It will allow users to leverage a local application to manage data disclosure and large data sets without the IT investment of developing custom applications. The first users of SEED will be agencies that need to collect, store, and report/share large data sets generated by benchmarking, energy auditing, retro-commissioning or retrofitting of many buildings. Similarly, building owners and operators will use SEED to manage their own energy data in a common format and centralized location. SEED users will also control the disclosure of their information for compliance requirements, recognition programs such as ENERGY STAR, or data sharing with the Buildings Performance Database and/or other third parties at their discretion.

Cheifetz, D. Magnus↗

Utilizing Environmental Tracers to Reduce Groundwater Flow and Transport Model Parameter Uncertainties

Abstract Non‐uniqueness in groundwater model calibration is a primary source of uncertainty in groundwater flow and transport predictions. In this study, we investigate the ability of environmental tracer information to constrain groundwater model parameters. We utilize a pilot point calibration procedure conditioned to subsets of observed data including: liquid pressures, tritium ( 3 H), chlorofluorocarbon‐12 (CFC‐12), and sulfur hexafluoride (SF 6 ) concentrations; and groundwater apparent ages inferred from these environmental tracers, to quantify uncertainties in the heterogeneous permeability fields and infiltration rates of a steady‐state 2‐D synthetic aquifer and a transient 3‐D model of a field site located near Riverton, Wyoming (USA). To identify the relative data worth of each observation data type, the post‐calibration uncertainties of the optimal parameters for a given observation subset are compared to that from the full observation data set. Our results suggest that the calibration‐constrained permeability field uncertainties are largest when liquid pressures are used as the sole calibration data set. We find significant reduction in permeability uncertainty and increased predictive accuracy when the environmental tracer concentrations, rather than apparent groundwater ages, are used as calibration targets in the synthetic model. Calibration of the Riverton field site model using environmental tracer concentrations directly produces infiltration rate estimates with the lowest uncertainties, however; permeability field uncertainties remain similar between the environmental tracer concentration and apparent groundwater age calibration scenarios. This work provides insight on the data worth of environmental tracer information to calibrate groundwater models and highlights potential benefits of directly assimilating environmental tracer concentrations into model parameter estimation procedures.

54 ENVIRONMENTAL SCIENCES↗

Characterization of scatter in digital mammography from physical measurements

Purpose: That scattered radiation negatively impacts the quality of medical radiographic imaging is well known. In mammography, even slight amounts of scatter reduce the high contrast required for subtle soft-tissue imaging. In current clinical mammography, image contrast is partially improved by use of an antiscatter grid. This form of scatter rejection comes with a sizeable dose penalty related to the concomitant elimination of valuable primary radiation. Digital mammography allows the use of image processing as a method of scatter correction that might avoid effects that negatively impact primary radiation, while potentially providing more contrast improvement than is currently possible with a grid. For this approach to be feasible, a detailed characterization of the scatter is needed. Previous research has modeled scatter as a constant background that serves as a DC bias across the imaging surface. The goal of this study was to provide a more substantive data set for characterizing the spatially-variant features of scatter radiation at the image detector of modern mammography units. Methods: This data set was acquired from a model of the radiation beam as a matrix of very narrow rays or pencil beams. As each pencil beam penetrates tissue, the pencil widens in a predictable manner due to the production of scatter. The resultant spreading of the pencil beam at the detector surface can be characterized by two parameters: mean radial extent (MRE) and scatter fraction (SF). The SF and MRE were calculated from measurements obtained using the beam stop method. Two digital mammography units were utilized, and the SF and MRE were found as functions of target, filter, tube potential, phantom thickness, and presence or absence of a grid. These values were then used to generate general equations allowing the SF and MRE to be calculated for any combination of the above parameters. Results: With a grid, the SF ranged from a minimum of about 0.05 to a maximum of about 0.16, and the MRE ranged from about 3 to 13 mm. Without a grid, the SF ranged from a minimum of 0.25 to a maximum of 0.52, and the MRE ranged from about 20 to 45 mm. The SF with a grid demonstrated a mild dependence on target/filter combination and kV, whereas the SF without a grid was independent of these factors. The MRE demonstrated a complex relationship as a function of kV, with notable difference among target/filter combinations. The primary source of change in both the SF and MRE was phantom thickness. Conclusions: Because breast tissue varies spatially in physical density and elemental content, the effective thickness of breast tissue varies spatially across the imaging field, resulting in a spatially-variant scatter distribution in the imaging field. The data generated in this study can be used to characterize the scatter contribution on a point-by-point basis, for a variety of different techniques.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

COMBIgor (A data assistant for combinatorial scientists in Igor Pro) [SWR-19-16]

Combinatorial materials science experiments involve synthesis and spatially-resolved characterization of thin film sample libraries. As a result, the modern combinatorial materials science laboratory produces large, diverse, and complex data sets, requiring automation of analysis and visualization techniques. COMBIgor is a software package aimed to assist a combinatorial material scientists with large volumes of experimental data. This package, written in Igor Pro, offers a systematic approach to the loading, processing, and visualizing combinatorial data sets. COMBIgor is designed to be expanded on a laboratory, group, or individual basis to adopt additional loading, processing and visualization capabilities. By utilizing COMBIgor software package the burden of data management in combinatorial materials science experiments can be significantly reduced.

Bauers, Sage↗

X-RAY SPECTRAL ANALYSIS OF THE STEADY STATES OF GRS1915+105

We report on the X-ray spectral behavior within the steady states of GRS1915+105. Our work is based on the full data set of the source obtained using the Proportional Counter Array (PCA) on the Rossi X-ray Timing Explorer (RXTE) and 15 GHz radio data obtained using the Ryle Telescope. The steady observations within the X-ray data set naturally separated into two regions in the color–color diagram and we refer to these regions as steady-soft and steady-hard. GRS1915+105 displays significant curvature in the coronal component in both the soft and hard data within the RXTE/PCA bandpass. A majority of the steady-soft observations displays a roughly constant inner disk radius (R{sub in}), while the steady-hard observations display an evolving disk truncation which is correlated to the mass accretion rate through the disk. The disk flux and coronal flux are strongly correlated in steady-hard observations and very weakly correlated in the steady-soft observations. Within the steady-hard observations, we observe two particular circumstances when there are correlations between the coronal X-ray flux and the radio flux with log slopes η∼0.68±0.35 and η∼1.12±0.13. They are consistent with the upper and lower tracks of Gallo et al. (2012), respectively. A comparison of the model parameters to the state definitions shows that almost all of the steady-soft observations match the criteria of either a thermal or steep power-law state, while a large portion of the steady-hard observations match the hard-state criteria when the disk fraction constraint is neglected.

79 ASTRONOMY AND ASTROPHYSICS↗