Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “corrected data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Admiralty Inlet Advanced Turbulence Measurements: Final Data and Code Archive

Data and code that is not already in a public location that is used in Kilcher, Thomson, Harding, and Nylund (2017) "Turbulence Measurements from Compliant Moorings - Part II: Motion Correction" doi: 10.1175/JTECH-D-16-0213.1. The links point to Python source code used in the publication. All other files are source data used in the publication.

16 TIDAL AND WAVE POWER↗

Automated evaluation of quaternary structures from protein crystals

A correct assessment of the quaternary structure of proteins is a fundamental prerequisite to understanding their function, physico-chemical properties and mode of interaction with other proteins. Currently about 90% of structures in the Protein Data Bank are crystal structures, in which the correct quaternary structure is embedded in the crystal lattice among a number of crystal contacts. Computational methods are required to 1) classify all protein-protein contacts in crystal lattices as biologically relevant or crystal contacts and 2) provide an assessment of how the biologically relevant interfaces combine into a biological assembly. In our previous work we addressed the first problem with our EPPIC (Evolutionary Protein Protein Interface Classifier) method. Here, we present our solution to the second problem with a new method that combines the interface classification results with symmetry and topology considerations. The new algorithm enumerates all possible valid assemblies within the crystal using a graph representation of the lattice and predicts the most probable biological unit based on the pairwise interface scoring. Our method achieves 85% precision (ranging from 76% to 90% for different oligomeric types) on a new dataset of 1,481 biological assemblies with consensus of PDB annotations. Although almost the same precision is achieved by PISA, currently the most popular quaternary structure assignment method, we show that, due to the fundamentally different approach to the problem, the two methods are complementary and could be combined to improve biological assembly assignments.

59 BASIC BIOLOGICAL SCIENCES↗

A Framework for Closed-Loop Optimization of an Automated Mechanical Serial-Sectioning System via Run-to-Run Control as Applied to a Robo-Met.3D

Optimization of automated data collection is gaining increased interest for the purposes of enabling closed-loop self-correcting systems that inherently maximize operational efficiencies and reduce waste. Many data collection systems have several variables which influence data accuracy or consistency and which can require frequent user interaction to be monitored and maintained. Operating upon a Robo-MET.3D™ automated mechanical serial-sectioning system, a run-to-run control algorithm has been developed to accelerate data collection and reduce data inconsistency. Here, using historical data amassed over a decade of experiments, a linear regression model of the deterministic system dynamics is created and used to employ a run-to-run control algorithm that optimizes selected system inputs to reduce operator intervention and increase efficacy while reducing variance of system output.

42 ENGINEERING↗

Detection and Characterization of Intrusions to Network Parameter Data in Electric Power Systems

Combating cyberattacks is an emerging challenge in maintaining the reliable and economic operation of electric power systems. Possible cyberattacks include intrusions to the parameter data at a control center. In this class of attacks, algorithms at the control center are correctly executed, but the attacker's modification of the associated parameter data yields improper results. This paper proposes an algorithm for detecting and characterizing cyberattacks to network parameter data, with specific application to optimal power flow problems. The proposed algorithm evaluates whether historical operating point data are consistent with the network parameters. Inconsistencies indicating potential cyberattacks are characterized using historical operational data (power injections and voltage phasors) along with network parameter data. Simulated test cases illustrate the proposed algorithm's detection and characterization capabilities.

cybersecurity↗

Proxy-Based Bayesian Inversion Of Poroelastic Simulations To Interpret Strain Tensor Data Measured During Well Testing

The long runtimes of 3D poroelastic numerical simulators makes it impractical to interpret deformation datasets using many inversion schemes. Recent advances in instrumentation have made it possible to measure the strain tensor during well testing, but the lack of robust inversion methods is limiting the ability to interpret these data. We have developed an inversion workflow that reduces the number of computations required to complete a Bayesian inversion using DREAMzs. The workflow trains a KNN model using output from the poroelastic simulator, and then uses the KNN model as a proxy for the simulator during inversion. The workflow also includes a strategy for ensuring the results from the proxy model converge to the results from the simulator, ensuring the accuracy of the final results. An idealized example configured to represent a well test in a deep aquifer is used to verify that the workflow correctly identifies parameters and characterizes noise. Field data measured using strainmeters during an injection test at an oil reservoir in Oklahoma are used to evaluate performance with a real dataset. The workflow identified 265 history matching solutions out of 1240 total simulation runs (21% acceptance ratio), and the results are used to characterize posterior parameter distribution and evaluate the prediction uncertainty. This approach makes it feasible to invert strain data measured during well testing and this has the potential to improve the characterization of aquifers and reservoirs.

Roudini, Soheil↗

Generalization in quantum machine learning from few training data

Modern quantum machine learning (QML) methods involve variationally optimizing a parameterized quantum circuit on a training data set, and subsequently making predictions on a testing data set (i.e., generalizing). In this work, we provide a comprehensive study of generalization performance in QML after training on a limited number N of training data points. We show that the generalization error of a quantum machine learning model with T trainable gates scales at worst as $\sqrt{T/N}$. When only K$\ll$T gates have undergone substantial change in the optimization process, we prove that the generalization error improves to $\sqrt{K/N}$. Our results imply that the compiling of unitaries into a polynomial number of native gates, a crucial application for the quantum computing industry that typically uses exponential-size training data, can be sped up significantly. We also show that classification of quantum states across a phase transition with a quantum convolutional neural network requires only a very small training data set. Other potential applications include learning quantum error correcting codes or quantum dynamical simulation. Our work injects new hope into the field of QML, as good generalization is guaranteed from few training data.

97 MATHEMATICS AND COMPUTING↗

Ka-Band ARM Zenith Radar Corrections (KAZRCOR, KAZRCFRCOR) Value-Added Products

The KAZRCOR Value -added Product (VAP) performs several corrections to the ingested KAZR moments and also creates a significant detection mask for each radar mode. The VAP computes gaseous attenuation as a function of time and radial distance from the radar antenna, based on ambient meteorological observations, and corrects observed reflectivities for that effect. KAZRCOR also dealiases mean Doppler velocities to correct velocities whose magnitudes exceed the radar’s Nyquist velocity. Input KAZR data fields are passed through into the KAZRCOR output files, in their native time and range coordinates. Complementary corrected reflectivity and velocity fields are provided, along with a mask of significant detections and a number of data quality flags. This report covers the KAZRCOR VAP as applied to the original KAZR radars and the upgraded KAZR2 radars. Currently there are two separate code bases for the different radar versions, but once KAZR and KAZR2 data formats are harmonized, only a single code base will be required.

54 ENVIRONMENTAL SCIENCES↗

Nitromethane Decomposition via Automated Reaction Discovery and an Ab Initio Corrected Kinetic Model

In the explore the systematic construction of kinetic models from in silico reaction data for the decomposition of nitromethane. Our models are constructed in a computationally affordable manner by using reactions discovered through accelerated molecular dynamics simulations using the ReaxFF reactive force field. The reaction paths are then optimized to determine reaction rate parameters. We introduce a reaction barrier correction scheme that combines accurate thermochemical data from density functional theory with ReaxFF minimal energy paths. We validate our models across different thermodynamic regimes, showing predictions of gas phase CO and NO concentrations and high-pressure induction times that are similar to experimental data. The kinetic models are analyzed to find fundamental decomposition reactions in different thermodynamic regimes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The effect of drying temperature on the composition of biomass

The compositional quality of different lignocellulosic feedstocks influences their performance and potential demand at a biorefinery. Many analytical protocols for determining the composition or performance characteristics of biomass involve a drying step, where the drying temperature can vary depending on the specific protocol. To get reliable data, it is important to determine the correct drying temperature to vaporize the water without negatively impacting the compositional quality of the biomass. A comparison of drying temperature between 45 degrees C and 100 degrees C was performed using wheat straw and corn stover. Near-infrared (NIR) spectra were taken of the dried samples and compared using principal component analysis (PCA). Carbohydrates were analyzed using quantitative saccharification to determine sugar degradation. Analysis of variance was used to determine if there was a significant difference between drying at different temperatures. PCA showed an obvious separation in samples dried at different temperatures due to sample water content. However, quantitative saccharification data shows, within a 95% confidence interval, that there is no significant difference in sugar content for drying temperatures up to 100 degrees C for wheat straw and corn stover.

09 BIOMASS FUELS↗

Neutralino annihilation into massive quarks with supersymmetric QCD corrections

We compute the full O({alpha}{sub s}) supersymmetric (SUSY)-QCD corrections for neutralino annihilation into massive quarks through gauge or Higgs bosons and squarks in the minimal supersymmetric standard model, including the known resummation of logarithmically enhanced terms. The numerical impact of the corrections on the extraction of SUSY mass parameters from cosmological data is analyzed for gravity-mediated SUSY-breaking scenarios and shown to be sizable, so that these corrections must be included in common analysis tools.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Model-based dose calculations for {sup 125}I lung brachytherapy

Purpose: Model-baseddose calculations (MBDCs) are performed using patient computed tomography (CT) data for patients treated with intraoperative {sup 125}I lung brachytherapy at the Mayo Clinic Rochester. Various metallic artifact correction and tissue assignment schemes are considered and their effects on dose distributions are studied. Dose distributions are compared to those calculated under TG-43 assumptions. Methods: Dose distributions for six patients are calculated using phantoms derived from patient CT data and the EGSnrc user-code BrachyDose. {sup 125}I (GE Healthcare/Oncura model 6711) seeds are fully modeled. Four metallic artifact correction schemes are applied to the CT data phantoms: (1) no correction, (2) a filtered back-projection on a modified virtual sinogram, (3) the reassignment of CT numbers above a threshold in the vicinity of the seeds, and (4) a combination of (2) and (3). Tissue assignment is based on voxel CT number and mass density is assigned using a CT number to mass density calibration. Three tissue assignment schemes with varying levels of detail (20, 11, and 5 tissues) are applied to metallic artifact corrected phantoms. Simulations are also performed under TG-43 assumptions, i.e., seeds in homogeneous water with no interseed attenuation. Results: Significant dose differences (up to 40% for D{sub 90}) are observed between uncorrected and metallic artifact corrected phantoms. For phantoms created with metallic artifact correction schemes (3) and (4), dose volume metrics are generally in good agreement (less than 2% differences for all patients) although there are significant local dose differences. The application of the three tissue assignment schemes results in differences of up to 8% for D{sub 90}; these differences vary between patients. Significant dose differences are seen between fully modeled and TG-43 calculations with TG-43 underestimating the dose (up to 36% in D{sub 90}) for larger volumes containing higher proportions of healthy lung tissue. Conclusions: Metallic artifact correction is necessary for accurate application of MBDCs for lung brachytherapy; simpler threshold replacement methods may be sufficient for early adopters concerned with clinical dose metrics. Rigorous determination of voxel tissue parameters and tissue assignment is required for accurate dose calculations as different tissue assignment schemes can result in significantly different dose distributions. Significant differences are seen between MBDCs and TG-43 dose distributions with TG-43 underestimating dose in volumes containing healthy lung tissue.

61 RADIATION PROTECTION AND DOSIMETRY↗

A new Cepheid distance measurement and method for NGC 6822

We present a revised distance to the nearby galaxy NGC 6822 using a new multi-band fit to both previously published and new optical, near-, and mid-infrared data for Cepheid variables. The new data presented in this study include multi-epoch observations obtained in 3.6 μm and 4.5 μm with the Spitzer Space Telescope taken for the Carnegie Hubble Program. We also present new observations in J, H, and K{sub s} with FourStar on the Magellan Baade Telescope at Las Campanas Observatory. We determine mean magnitudes and present new period-luminosity relations in V, I, J, H, K{sub s} , Infrared Array Camera 3.6 μm, and 4.5 μm. In addition to using the multi-band distance moduli to calculate extinction and a true distance, we present a new method for determining an extinction-corrected distance modulus from multi-band data with varying sample sizes. We combine the distance moduli and extinction for individual stars to determine E(B – V) = 0.35 ± 0.04 and a true distance modulus μ {sub o} = 23.38 ± 0.02{sub stat} ± 0.04{sub sys}.

79 ASTRONOMY AND ASTROPHYSICS↗

Copper K-shell emission cross sections for laser–solid experiments

Published measurements and models of the cross section for electrons causing K-shell emission from copper are reviewed to find a suitable expression to use when analyzing K{sub α}-emission measurements in laser–solid experiments at peak intensities above 10{sup 18} W/cm{sup 2}. Few measurements exist in the 0.1- to 10-MeV electron energy range currently of interest, leaving a number of possible suitable models that are summarized here with a number of typing errors corrected. Two different limiting forms for the cross section at relativistic energies are used, and existing measurements do not give a clear indication as to which is correct. Comparison with the limiting form of electron stopping power indicates an alternative relativistic form and also that the density-effect correction will be important in copper above 10 MeV. For data analysis relying on relative K{sub α} emission caused by electrons with energy much greater than the K-shell binding energy, the existing uncertainty in cross sections is unimportant, but it will be a source of uncertainty when using absolute values and for electron energies up to ∼6× the binding energy. K-shell emission caused by photons and protons is also briefly reviewed.

74 ATOMIC AND MOLECULAR PHYSICS↗

Load Deflection Data (LDDATA)

The current data set is load deflection data (Stress vs strain for compression stress and stress vs elongation for tension stress) from a material test. The goal of the test was to characterize this rubber-like material by looking at different variables: sample creation process, anisotropy, temperature, etc. The data will be used with the Texas A&M Online Research Experience for Undergraduates (O-REU) program. This program is joint with LANL. The student is not an official LANL student so they will not be able to access data and documents on the yellow. The load deflection data set is unclassified and will be sent to the student for analysis. Analysis will include curve fitting, scalar value analysis (stiffness, toughness, etc.) and analysis of variance to determine what variables statistically affect the response while correcting for covariates (temperature soak time and humidity). Data will be stored as Matlab structs and as HDF5 files. Same data, different formats.

36 MATERIALS SCIENCE↗

The impact of target mass correction on polarized parton distribution functions

Considering the nonzero mass effect of the target in extracting polarized parton distribution functions (PPDFs) in preasymptotic region is not negligible. We extract PPDFs from available proton structure function data and study the numerical effects of target mass corrections (TMCs). PPDFs with and without this correction are compared.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time-critical database condition data handling in the CMS experiment during the first data taking period

Automatic, synchronous and reliable population of the condition databases is critical for the correct operation of the online selection as well as of the offline reconstruction and analysis of data. In this complex infrastructure, monitoring and fast detection of errors is a very challenging task. In this paper, we describe the CMS experiment system to process and populate the Condition Databases and make condition data promptly available both online for the high-level trigger and offline for reconstruction. The data are automatically collected using centralized jobs or are 'dropped' by the users in dedicated services (offline and online drop-box), which synchronize them and take care of writing them into the online database. Then they are automatically streamed to the offline database, and thus are immediately accessible offline worldwide. The condition data are managed by different users using a wide range of applications.In normal operation the database monitor is used to provide simple timing information and the history of all transactions for all database accounts, and in the case of faults it is used to return simple error messages and more complete debugging information.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A model-based scatter artifacts correction for cone beam CT

Purpose: Due to the increased axial coverage of multislice computed tomography (CT) and the introduction of flat detectors, the size of x-ray illumination fields has grown dramatically, causing an increase in scatter radiation. For CT imaging, scatter is a significant issue that introduces shading artifact, streaks, as well as reduced contrast and Hounsfield Units (HU) accuracy. The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging. Methods: The method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain or projection domain. A denoising algorithm designed specifically for Poisson signals is then applied to derive the final scatter distribution. Qualitative and quantitative evaluations using thorax and abdomen phantoms with Monte Carlo (MC) simulations, experimental Catphan phantom data, and in vivo human data acquired for a clinical image guided radiation therapy were performed. Scatter correction in both projection domain and image domain was conducted and the influences of segmentation method, mismatched attenuation coefficients, and spectrum model as well as parameter selection were also investigated. Results: Results show that the proposed algorithm can significantly reduce scatter artifacts and recover the correct HU in either projection domain or image domain. For the MC thorax phantom study, four-components segmentation yields the best results, while the results of three-components segmentation are still acceptable. The parameters (iteration number K and weight β) affect the accuracy of the scatter correction and the results get improved as K and β increase. It was found that variations in attenuation coefficient accuracies only slightly impact the performance of the proposed processing. For the Catphan phantom data, the mean value over all pixels in the residual image is reduced from −21.8 to −0.2 HU and 0.7 HU for projection domain and image domain, respectively. The contrast of the in vivo human images is greatly improved after correction. Conclusions: The software-based technique has a number of advantages, such as high computational efficiency and accuracy, and the capability of performing scatter correction without modifying the clinical workflow (i.e., no extra scan/measurement data are needed) or modifying the imaging hardware. When implemented practically, this should improve the accuracy of CBCT image quantitation and significantly impact CBCT-based interventional procedures and adaptive radiation therapy.

60 APPLIED LIFE SCIENCES↗

Evaluation of MOPITT Version 7 joint TIR–NIR X CO retrievals with TCCON

Observations of carbon monoxide (CO) from the Measurements Of Pollution In The Troposphere (MOPITT) instrument aboard the Terra spacecraft were expected to have an accuracy of 10 % prior to the launch in 1999. Here we evaluate MOPITT Version 7 joint (V7J) thermal-infrared and near-infrared (TIR–NIR) retrieval accuracy and precision and suggest ways to further improve the accuracy of the observations. We take five steps involving filtering or bias corrections to reduce scatter and bias in the data relative to other MOPITT soundings and ground-based measurements. (1) We apply a preliminary filtering scheme in which measurements over snow and ice are removed. (2) We find a systematic pairwise bias among the four MOPITT along-track detectors (pixels) on the order of 3–4 ppb with a small temporal trend, which we remove on a global scale using a temporally trended bias correction. (3) Using a small-region approximation (SRA), a new filtering scheme is developed and applied based on additional quality indicators such as the signal-to-noise ratio (SNR). After applying these new filters, the root-mean-squared error computed using the local median from the SRA over 16 years of global observations decreases from 3.84 to 2.55 ppb. (4) We also use the SRA to find variability in MOPITT retrieval anomalies that relates to retrieval parameters. We apply a bias correction to one parameter from this analysis. (5) After applying the previous bias corrections and filtering, we compare the MOPITT results with the GGG2014 ground-based Total Carbon Column Observing Network (TCCON) observations to obtain an overall global bias correction. These comparisons show that MOPITT V7J is biased high by about 6 %–8 %, which is similar to past studies using independent validation datasets on V6J. When using TCCON spectrometric column retrievals without the standard airmass correction or scaling to aircraft (WMO scale), the ground- and satellite-based observations overall agree to better than 0.5 %. GEOS-Chem data assimilations are used to estimate the influence of filtering and scaling to TCCON on global CO and tend to pull concentrations away from the prior fluxes and closer to the truth. We conclude with suggestions for further improving the MOPITT data products.

Hedelius, Jacob K. (ORCID:0000000320257519)↗