Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cooled”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Dust cooling of hot gas.

The cooling rates of a hot gas by ion-grain collisions are shown to be significant at temperatures above 1 million K. The importance of this cooling mechanism in certain phases of supernova explosions is noted. High-temperature modifications of this cooling mechanism in astronomical sources are discussed. A cooling curve is plotted for collisionally ionized gas containing cosmic abundances of heavy elements and graphite grains.

Ostriker, J. P.↗

Market potential for solar heating and cooling in buildings

The use of solar heating and cooling for buildings as a method of conserving fossil fuels is discussed. The residential and commercial end use consumption of energy is tabulated. A survey to project the energy requirements for home and industry heating and cooling is developed. The survey indicates that there is a market potential for solar heating and cooling of buildings. A prediction of three to five billion dollars per year as the potential for solar heating and cooling is made.

Source record↗

An adverse effect of film cooling on the suction surface of a turbine vane

Film-cooling-air ejection from the suction surface of a turbine vane was investigated. This investigation was conducted in a four-vane cascade on a J75 size turbine vane which had a row of holes near the leading edge. The experimental data are presented. It was found that a small amount of film-cooling air has a detrimental effect on the downstream vane wall cooling effectiveness. It was also shown that the presence of the film-cooling holes, without blowing, also cause an increase in vane wall temperatures. These results came from an increase in the gas-side heat transfer coefficient that was apparently caused by a laminar or transitional boundary layer becoming transitional or turbulent.

Gladden, H. J.↗

Data and results from a study of internal convective cooling systems for hypersonic aircraft

An extensive survey of current and future airframe construction materials and coolants was conducted, so that the most promising candidates could be examined for cooled-panel, cooling-system and airframe concepts. Consideration was given to over 100 structural materials, 50 coolants, 6 classes of structural panel concepts, 4 classes of thermal panel concepts with numerous variations, and 3 overall cooled airframe design approaches, including unshielded, shielded, and dual temperature types. The concept identification and parametric comparison phase examined all major elements of the convectively cooled airframe, including the differing requirements at various locations on the aircraft. The parametric results were used for the investigation to two separate vehicles, a hypersonic transport with a length of 96 meters (314 feet) and a weight of 24,000 kg (528,600 lb) and a hypersonic research airplane, with a length of 25m (80 ft) and a weight of 20,300 kg (447,000 lb).

Anthony, F. M.↗

Cooling histories of lunar rocks based on opaque mineral geothermometers

The application of experimentally derived data on (1) the Zr partitioning between coexisting ilmenite and ulvospinel and (2) the Ti partitioning between coexisting troilite and ilmenite has allowed the discernment of differences in subsolidus cooling histories of lunar rocks - e.g., the Apollo 15 Type I Mare basalts. The rocks which show Zr partitionings reequilibrated to lower temperature (i.e., below 950 C), as a result of slow cooling, also show evidence for subsolidus reduction of ulvospinel to ilmenite + native Fe. It is suggested that the presence of ulvospinel reduction is not evidence a priori that these rocks have undergone more reducing conditions than the other Apollo 15 Mare basalts; it may only indicate that the cooling rates were slower in that subsolidus temperature range (i.e., much less than 900 C) where oxygen fugacity values were favorable for ulvospinel reduction. The rocks with higher temperature Zr partitionings and no ulvospinel reduction may have cooled under the same fugacity conditions but at a faster rate.

Taylor, L. A.↗

Structure and properties of a splat cooled 2024 aluminum alloy

In the investigation the alloy was melted, heated to 750 C, and atomized into fine droplets. The droplets were rapidly quenched against a heavy copper disk rotating at 1725 rpm. The resultant splat cooled flakes were screened. Three flake sizes were finally separated. Flakes of each size were separately processed. The characteristics of the splat cooling process and the properties of the obtained products are discussed. Splat cooling against a metallic substrate permits cooling rates up to about 1,000,000 deg C/sec. Increases in yield strength and tensile strength of 14 to 19% are observed for the splat products. Other improvements are connected with increases in fatigue life and stress rupture performance.

Lebo, M.↗

Modular liquid-cooled helmet liner for thermal comfort

A modular liquid-cooled helmet liner made of eight form-fitting neoprene patches was constructed. The liner was integrated into the sweatband of an Army SPH-4 helicopter aircrew helmet. This assembly was tested on four subjects seated in a hot (47 C), humid (40%) environment. Results indicate a marked reduction in the rate of increase of physiological body functions. Rectal temperature, weight loss, heart rate, and strain indices are all reduced to approximately 50% of uncooled levels. The cooling liner removed from 10% to 30% of total metabolic heat produced. This study also demonstrated the technical feasilibity of using a cooling liner in conjunction with a standard hard helmet. Potential applications of the cooling liner in thermally stressful environments are numerous, notably for helicopter and other aircrews.

Williams, B. A.↗

Aerodynamic performance of a fully film cooled core turbine vane tested with cold air in a two-dimensional cascade

The aerodynamic performance of a fully film cooled core turbine vane was investigated experimentally in a two-dimensional cascade of 10 vanes. Three of the 10 vanes were cooled; the others were solid (uncooled) vanes. Cold air was used for both the primary and coolant flows. The cascade test covered a range of pressure ratios corresponding to ideal exit critical velocity ratios of 0.6 to 0.95 and a range of coolant flow rates to 7.5 percent of the primary flow. The coolant flow was varied by changing the coolant supply pressure. The principal measurements were cross-channel surveys of exit total pressure, static pressure, and flow angle. The results presented include exit survey data and overall performance in terms of loss, flow angle, and weight flow for the range of exit velocity ratios and coolant flows investigated. The performance of the cooled vane is compared with the performance of an uncooled vane of the same profile and also with the performance obtained with a single cooled vane in the 10-vane cascade.

Stabe, R. G.↗

Fail-safe system for activity cooled supersonic and hypersonic aircraft

A fail-safe-system concept was studied as an alternative to a redundant active cooling system for supersonic and hypersonic aircraft which use the heat sink of liquid-hydrogen fuel for cooling the aircraft structure. This concept consists of an abort maneuver by the aircraft and a passive thermal protection system (TPS) for the aircraft skin. The abort manuever provides a low-heat-load descent from normal cruise speed to a lower speed at which cooling is unnecessary, and the passive TPS allows the aircraft skin to absorb the abort heat load without exceeding critical skin temperature. On the basis of results obtained, it appears that this fail-safe-system concept warrants further consideration, inasmuch as a fail-safe system could possibly replace a redundant active cooling system with no increase in weight and would offer other potential advantages.

Jones, R. A.↗

The development of a solar residential heating and cooling system

The MSFC solar heating and cooling facility was assembled to demonstrate the engineering feasibility of utilizing solar energy for heating and cooling buildings, to provide an engineering evaluation of the total system and the key subsystems, and to investigate areas of possible improvement in design and efficiency. The basic solar heating and cooling system utilizes a flat plate solar energy collector, a large water tank for thermal energy storage, heat exchangers for space heating, and an absorption cycle air conditioner for space cooling. A complete description of all systems is given. Development activities for this test system included assembly, checkout, operation, modification, and data analysis, all of which are discussed. Selected data analyses for the first 15 weeks of testing are included, findings associated with energy storage and the energy storage system are outlined, and conclusions resulting from test findings are provided. An evaluation of the data for summer operation indicates that the current system is capable of supplying an average of 50 percent of the thermal energy required to drive the air conditioner. Preliminary evaluation of data collected for operation in the heating mode during the winter indicates that nearly 100 percent of the thermal energy required for heating can be supplied by the system.

Source record↗

Tests of a reduced-scale experimental model of a building solar heating-cooling system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable (e.g., heating and cooling load of a building and collected solar energy) with experimental equipment. The experimental system model was based on the loads and components used in the Solar Building Test Facility (SBTF), which includes a 1394 sq m solar collector field at NASA Langley. These tests covered 5 continuous days under summer conditions. For the system model up to 55 percent of the simulated collected solar energy was used for the building load. This amount of solar energy supplied 35 percent of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, which would make it similar to the actual SBTF, 75 percent of the collected solar energy would be used. This amount would supply approximately 50 percent of the building cooling load. A higher fraction of solar energy is possible with a more performance-optimized system.

Namkoong, D.↗

Heating and cooling of the thermal X-ray plasma in solar flares

Characteristic times for the heating and cooling of thermal plasma in X-ray flares are estimated from the time profile of the flare and from the temperature, emission measure and length scale of the flare-heated plasma. It is implied from the empirical values for the characteristic times that flares are produced by magnetic field reconnection; that conductive cooling of the plasma dominates radiative cooling; and that reconnection heating and conductive cooling are approximately in balance at thermal X-ray maximum.

Moore, R. L.↗

Shock wave/turbulent boundary-layer interactions with and without surface cooling

An experimental investigation was conducted to delineate the structure of the flowfield and temperature distributions in a shock wave/turbulent boundary-layer interaction with and without surface cooling. The Mach number upstream was about 3.5, and the wave angle was 23 deg. The wall to stagnation temperature ratio was 0.44 with cooling and 1.1 with heating. A detailed map of the interaction flowfields deduced from numerous boundary-layer traversing stations revealed the influence of wall cooling on the flowfield, wave structure, and size of the flow separation region. With surface cooling, the size of the separation region was much smaller, and the separation and reflected shock waves merged together near the edge of the velocity boundary layer, extending into the freestream as one wave.

Back, L. H.↗

Cyclic structural analysis of air-cooled gas turbine blades and vanes

The creep fatigue behavior of a fully impingement cooled blade for four cyclic cases was analyzed by using the Elas 55, finite element, nonlinear structural computer program. Expected cyclic lives were calculated by using the method of strainrange partitioning for reversed inelastic strains and time fractions for ratcheted tensile creep strains. Strainrange partitioning was also applied to previous results from a one dimensional cyclic analysis of a film impingement cooled vane. The analyses indicated that strainrange partitioning is more applicable to a constrained airfoil such as the film impingement cooled vane than to the relatively unconstrained fully impingement cooled airfoil.

Kaufman, A.↗

Liquid cooled brassiere and method of diagnosing malignant tumors therewith

A device for enhancing the detection of malignant tissue in the breasts of a woman was described. A brassiere-like garment which is fitted with a pair of liquid-perfused cooling panels which completely and compliantly cover the breasts and upper torso was studied. The garment is connected by plastic tubing to a liquid cooling system comprising a fluid pump, a solenoid control valve for controlling the flow of fluid to either the cooling unit or the heating unit, a fluid reservoir, a temperature sensor in the reservoir, and a restrictor valve to control the pressure in the garment inlet cooling line.

Elkins, W.↗

Heat transfer to a full-coverage film-cooled surface with 30 degree slant-hole injection

Heat transfer behavior was studied in a turbulent boundary layer with full coverage film cooling through an array of discrete holes and with injection 30 deg to the wall surface in the downstream direction. Stanton numbers were measured for a staggered hole pattern with pitch-to-diameter ratios of 5 and 10, an injection mass flux ratio range of 0.1 to 1.3, and a range of Reynolds number Re sub x of 150,000 to 5 million. Air was used as the working fluid, and the mainstream velocity varied from 9.8 to 34.2 m/sec (32 to 112 ft/sec). The data were taken for secondary injection temperature equal to the wall temperature and also equal to the mainstream temperature. The data may be used to obtain Stanton number as a continuous function of the injectant temperature by use of linear superposition theory. The heat transfer coefficient is defined on the basis of a mainstream-to-wall temperature difference. This definition permits direct comparison of performance between film cooling and transpiration cooling. A differential prediction method was developed to predict the film cooling data base. The method utilizes a two-dimensional boundary layer program with routines to model the injection process and turbulence augmentation. The program marches in the streamwise direction, and when a row of holes is encountered, it stops and injects fluid into the boundary layer. The turbulence level is modeled by algebraically augmenting the mixing length, with the augmentation keyed to a penetration distance for the injected fluid.

Crawford, M. E.↗

Air cooling of disk of a solid integrally cast turbine rotor for an automotive gas turbine

A thermal analysis is made of surface cooling of a solid, integrally cast turbine rotor disk for an automotive gas turbine engine. Air purge and impingement cooling schemes are considered and compared with an uncooled reference case. Substantial reductions in blade temperature are predicted with each of the cooling schemes studied. It is shown that air cooling can result in a substantial gain in the stress-rupture life of the blade. Alternatively, increases in the turbine inlet temperature are possible.

Gladden, H. J.↗