Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “column”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

OSPREY Model

The absence of industrial scale nuclear fuel reprocessing in the U.S. has precluded the necessary driver for developing the advanced simulation capability now prevalent in so many other countries. Thus, it is essential to model complex series of unit operations to simulate, understand, and predict inherent transient behavior and feedback loops. A capability of accurately simulating the dynamic behavior of advanced fuel cycle separation processes will provide substantial cost savings and many technical benefits. The specific fuel cycle separation process discussed in this report is the off-gas treatment system. The off-gas separation consists of a series of scrubbers and adsorption beds to capture constituents of interest. Dynamic models are being developed to simulate each unit operation involved so each unit operation can be used as a stand-alone model and in series with multiple others. Currently, an adsorption model has been developed within Multi-physics Object Oriented Simulation Environment (MOOSE) developed at the Idaho National Laboratory (INL). Off-gas Separation and REcoverY (OSPREY) models the adsorption of off-gas constituents for dispersed plug flow in a packed bed under non-isothermal and non-isobaric conditions. Inputs to the model include gas, sorbent, and column properties, equilibrium and kinetic data, and inlet conditions. The simulation outputs component concentrations along the column length as a function of time from which breakthrough data is obtained. The breakthrough data can be used to determine bed capacity, which in turn can be used to size columns. It also outputs temperature along the column length as a function of time and pressure drop along the column length. Experimental data and parameters were input into the adsorption model to develop models specific for krypton adsorption. The same can be done for iodine, xenon, and tritium. The model will be validated with experimental breakthrough curves. Customers will be given access to OSPREY to used and evaluate the model.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Colloid-Facilitated Transport of 137 Cs in Fracture-Fill Material. Experiments and Modeling

In this study, we demonstrate how a combination of batch sorption/desorption experiments and column transport experiments were used to effectively parameterize a model describing the colloid-facilitated transport of Cs in the Grimsel granodiorite/FFM system. Cs partition coefficient estimates onto both the colloids and the stationary media obtained from the batch experiments were used as initial estimates of partition coefficients in the column experiments, and then the column experiment results were used to obtain refined estimates of the number of different sorption sites and the adsorption and desorption rate constants of the sites. The desorption portion of the column breakthrough curves highlighted the importance of accounting for adsorption-desorption hysteresis (or a very nonlinear adsorption isotherm) of the Cs on the FFM in the model, and this portion of the breakthrough curves also dictated that there be at least two different types of sorption sites on the FFM. In the end, the two-site model parameters estimated from the column experiments provided excellent matches to the batch adsorption/desorption data, which provided a measure of assurance in the validity of the model.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated Clean Chemistry for Bulk Analysis of Environmental Swipe Samples – Final Report

Sample preparation methods for mass spectrometry are being automated using commercial-off-the-shelf (COTS) equipment to shorten lengthy and costly manual chemical purification procedures. This development addresses a serious need in the International Atomic Energy Agency’s (IAEA) Network of Analytical Laboratories (NWAL) to increase efficiency in the Bulk Analysis of Environmental Samples for Safeguards program with a method that allows unattended, overnight operation. In collaboration with Elemental Scientific Inc. (ESI), the prepFAST-MC2 was designed based on COTS equipment. It was modified for uranium/plutonium separations using renewable columns packed with Eichrom TEVA® and UTEVA® resins, with a chemical separation method based on the Oak Ridge National Laboratory (ORNL) NWAL chemical procedure. Initial verification of individual columns yielded small elution volumes with consistent elution profiles and good recovery. Combined column calibration demonstrated ample separation without crosscontamination of the eluent. Automated packing and unpacking of the built-in columns initially showed >15% deviation in resin loading by weight, which can lead to inconsistent separations. Optimization of the packing and unpacking methods led to a reduction in the variability of the packed resin to less than 5% daily. Based on the initial experience at ORNL with the prepFAST-MC2, a second-generation model, the prepFAST-SR, was built by ESI. The newly designed prepFAST-SR has several upgrades compared with the original prepFAST-MC2. The upgrades largely addressed issues with the reliability of unpacking the Eichrom columns and with ventilation to ensure adequate removal of acid vapors. Both systems are currently installed in the Ultra-Trace Forensics Science Center at ORNL. Separations of mixed uranium and plutonium samples containing certified reference materials were analyzed by multi-collector inductively coupled plasma mass spectrometry and yielded good results. Current efforts have demonstrated a wider applicability of the prepFAST system. Near-quantitative removal of metal interferences was achieved with the system in both uranium and plutonium separated fractions. Successful system validation was completed with several archived samples. Isotopic results from archived samples and certified reference materials were well within data quality limits for the IAEA NWAL. Additional COTS equipment has been evaluated for its potential to aid the prepFAST-SR system in reducing the time allotments and cleanroom infrastructure requirements for accurate separations. Overall, these efforts help ensure continued efficient and effective operation of the NWAL. Comparison of the amount of personnel time necessary for successful manual vs. automated chemical separations showed a significant decrease in hands-on time from 9.8 hours to 35 minutes for seven samples, respectively. This documented time savings and reduced labor translates to a significant cost savings per sample. Overall, the system will enable faster sample reporting times at reduced cost by limiting personnel hours dedicated to the chemical separation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing of an Integrated Iodine Scrubber and Polishing Bed System

In 2016 an initial engineering evaluation and design of the off-gas abatement systems required for a hypothetical 1000 t/yr used nuclear fuel (UNF) reprocessing facility treating 5 yr–cooled, 60 GWd/tIHM UNF was completed. In this study two types of silver-based iodine sorbents were considered. The first was a silver-exchanged mordenite (AgZ), and the second was a silver-functionalized silica aerogel. In the initial design of the dissolver off-gas (DOG) iodine capture beds, the sorbent capacity was assumed to be 40 mg I/g sorbent. The total iodine released from the fuel, used as input for the design of the DOG system, was 1.635 kg/day. Tramp halogens increased this to ~5.1 kg/day on an iodine equivalent basis. The daily consumption of iodine sorbent was ~166 kg (including the mass transfer zones that have lower iodine loading). The iodine capture system was designed to utilize five beds in parallel. In this design each bed was ~1 m in diameter and 1.5 m long. This design allowed the beds to remain on line for 20 days, but at that point all five beds would need to be replaced, resulting in considerable material handling. It was proposed that the bed life could be extended and the number of parallel beds reduced if an aqueous iodine scrubber preceded the solid sorbent iodine capture beds. The testing described in this report was intended to provide an evaluation of an integrated system in which bulk iodine would first be removed by an aqueous NaOH scrubber with a target iodine decontamination factor (DF) of 10 to 50. This would reduce the sorbent usage by 90 to 95% and significantly reduce the associated frequent remote handling of the iodine filter beds. The effluent from the scrubber would then be passed through an AgZ sorbent bed to remove residual iodine. The integration of these unit operations was intended to demonstrate an iodine DF of >1000, which would facilitate regulatory compliance with regards to total volatile radionuclide emission from a reprocessing facility. Initial baseline performance testing of the scrubber system includes the characterization of CO 2 removal by the aqueous NaOH scrubber as a function of temperature, caustic concentration, packing length, liquid-to-gas mass ratio, and liquid flow rate. It was found that when the column was well wetted, very high CO 2 DFs were achieved (>650 and potentially as high as 15,000), preventing the ability to elucidate the effects of each specific variable tested. The L/G ratio in this system was not representative of typical L/G ratios found in industrial-scale scrubber systems. By significantly lowering the liquid recirculation rate to the point that column wetting was marginal, some significant variations in the CO 2 DF or CO 2 effluent concentrations could be observed. The additional tests conducted under these more adverse conditions still showed CO 2 DFs >100. The only operational parameter with significant effects was determined to be column length, with increased column length resulting in higher CO 2 DFs. Following these CO 2 tests, a single iodine scrubber test was performed deliberately at a condition indicated by the CO 2 demonstration to result in poor column performance. This was intended to establish a lower performance bound for iodine removal by the aqueous scrubber. The result showed that even under the adverse operating conditions, an iodine DF of >100 could be achieved. Finally, the aqueous scrubber and a AgZ polishing bed were integrated. This simple caustic scrubber system achieved an iodine DF of >12,000 for just the scrubber portion. Using this iodine DF, the iodine loading on the polishing bed was reduced by 99.993%. The performance of that integrated system was compared to a system including only a AgZ sorbent bed. The system without the scrubber also showed iodine DFs >3000 until breakthrough was observed. The loading on the saturated portion of the bed averaged 87.2 mg I 2 /gm AgZ. Comparing the penetration of iodine into the sorbent beds for these two systems showed a marked difference; the penetration with the scrubber was only 0.65 cm at a maximum loading of 0.11 mg I 2 /gm AgZ, whereas for the case without the caustic scrubber, the bed was saturated for the first 7 cm and breakthrough of the 13.3 cm bed occurred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Drying of Crystalline Silicotitanate (CST) Beds by Air Flow

The Direct Feed Low-Activity Waste (DFLAW) process has been proposed to support early production of immobilized low-activity waste (LAW) at the Hanford Site. The tank farm contractor Washington River Protection Solutions, LLC (WRPS) is developing the Tank-Side Cesium Removal (TSCR) system to accomplish the treatment objectives. The TSCR system is being designed and built by AVANTech, Inc. for WRPS and will use a filter to remove any entrained solids in the LAW and will use columns of crystalline silicotitanate (CST) ion exchange media to remove 137 Cs. A key step in preparing used columns of CST for transportation and interim storage is draining and drying of the CST beds. The purpose of this study is to document testing activities that quantify the drying of full-height beds of CST material in a laboratory column that is scaled to represent the drying process of the planned full-scale CST columns to be used in the TSCR system. The purpose also includes demonstrating that CST material within the scaled column, when dried with air injection, will pass the U.S. Environmental Protection Agency’s Paint Filter Liquids Test.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

ZAM Modeling Study to Support the Tank Closure Cesium Removal (TCCR) 1A Unit

Currently at the Savannah River Site (SRS), the Tank Closure Cesium Removal (TCCR) is an “at-tank” process designed to remove cesium from aqueous tank waste. Cesium will be removed by ion exchange using the engineered IONSIV® R9120 form of Crystalline Silicotitanate (CST) media. The current TCCR design has two columns online in a lead-lag configuration to optimize media usage and achieve the target decontamination. Once the lead column is saturated with cesium, it will be removed from service, the lag column will rotate into the lead position, and a new column with fresh ion-exchange media will be placed into the lag position. The TCCR process for cesium removal from Tank 10H is detailed in X-SOW-H- 00002. Demonstration of the system began in early calendar year 2019 with two batches of salt solution generated by dissolving saltcake in Tank 10H, followed by processing of these batches through the TCCR system. A third TCCR Tank 10H dissolved saltcake batch is scheduled for processing soon. Upon completion of the demonstration with Tank 10H dissolved saltcake, Tank 9H salt solution will be transferred to Tank 10H and subsequently processed through the TCCR unit with new CST media (referred to as R9120-B 30x60) added to new IX columns. The TCCR processing campaign of Tank 9H salt solution is referred to as TCCR-1A .

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SR19007 - Future TCAP Implementation Issues

This project demonstrates the success of the PDRD program in bringing a concept from the R&D phase to direct plant funding. Although Mini-TCAP technology is overall at a TRL of ~6.5, the specific questions addressed in this project were brought from a low (2-3 TRL) to a TRL 5 over the course of the project. This project successfully completed all initial goals ahead of schedule (inventory control, guard bed, ammonia impact, and cycle time) and furthermore addressed additional scope (continued TCAP evaluation, ion chamber) in FY20. First, this project resolved minor inventory control issues by introducing a new parameter tracking and correcting for inventory changes over multiple cycles. This project also involved modification of the previously constructed plant-configured Mini-TCAP in order to allow ammonia impurity studies. TCAP was tested with ammonia in the feed stream both with and without a guard bed present to determine guard bed efficacy and the effect of ammonia if it enters TCAP. The TCAP columns were then replaced with brazed columns, where the LN2 cooling coil is brazed to the column and the column is self-brazed along the coils. This drastically improved heat transfer and consequently reduced cycle time compared to the previous columns, in which the coils were mechanically held in place. Finally, additional scopes were taken on in FY20, including evaluation of TCAP with faster cycle time and procurement of ion chambers for future TCAP integration.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Behavior of Natural Seep Vents: Analysis of Field and Laboratory Observations and Modeling (Final Scientific/Technical Report)

In this project, we have analyzed data collected by the U.S. Department of Energy (DOE), National Energy Technology Laboratory (NETL) in a high pressure water tunnel (HPWT) and data from two research cruises to natural seeps in the Gulf of Mexico to adapt and validate a numerical model to predict the dynamics of natural seeps in the deep oceans. The HPWT data include video observations of the shrinkage rate of individual methane and natural gas bubbles under simulated deep-water conditions. Field data were collected during two cruises by the Gulf Integrated Spill Research (GISR) Consortium led by Texas A&M University and funded by the Gulf of Mexico Research Initiative (GoMRI). These data included in situ observations from a remotely operated vehicle (ROV) of gas bubbles at two natural seep sites in the Gulf and acoustic observations of the natural seep bubble flares in the ocean water column. The acoustic data were from multibeam echosounders, one mounted in a forward-looking orientation on the ROV and another mounted down-looking in the haul of the ship. All of these laboratory and field data were focused on the dynamics of natural gas bubbles at temperatures and pressures favorable for clathrate hydrate formation between the gas and water. Our analyses of this data focused on understanding the mechanisms responsible for gas bubble dissolution within the hydrate stability zone (HSZ) of the oceans. Ice-like hydrate shells may form on the bubble-water interface under these conditions, and it was unknown how this might affect the mass transfer of gas into the ocean. We were able to extract bubble shrinkage rates from the HPWT datasets. Using this data we determined that mass transfer coefficients with and without a hydrate shell match empirical values for bubbles in contaminated systems (so-called dirty bubbles contaminated by naturally occurring surfactants). We also showed that free gas, and not gas hydrate, is the dominant dissolving phase when the hydrate sub-cooling is below 11 degree Celsius (temperature difference between hydrate the hydrate formation temperature and ambient temperator) or the pressure is reducing as bubbles rise through the ocean water column. Using this mass transfer model, our numerical model of bubble dissolution matched the over 200 HPWT experiments with an average error of 10% for predicting the bubble size at the end of an experiment. From field data in the literature, we also observed that gas bubbles dissolve faster when they are initially released, following mass transfer coefficients for so-called clean-bubbles (those not yet contaminated by surfactants). Shortly after release within the HSZ, a hydrate shell forms on the bubble-water interface, and the mass transfer reduces to rates matching those of dirty bubbles. We correlated this transition time from clean to dirty bubble behavior with the initial bubble surface area and the hydrate sub-cooling. With this model for hydrate formation time and using the mass transfer coefficients deduced from the HPWT data, we validated our numerical model for predicting the rise heights of natural seep flares in the oceans. Flare heights are commonly observed in haul-mounted acoustic multibeam data. The numerical model predicts bubbles to rise high in the ocean water column owing to the slower mass transfer rates for dirty bubbles that accompany the majority of their rise time. We found that the numerical model predictions matched the observed flare heights within 5% to 10% accuracy when we compared the rise heights of the largest bubbles released from the seafloor with the bubbles acoustically visible in the multibeam data. Bubbles become acoustically transparent as they shrink to sizes of order 1 mm in diameter for the multibeam frequencies used in the field. The forward-looking multibeam on the ROV also provided data on the lateral spreading of bubbles in natural seep flares. Our analysis of this data showed that spreading follows a diffusion process, with the effective diffusivity correlating with the wobbling length scale of these ellipsoidal bubbles. When we apply this diffusivity in a random displacement model of bubble spreading, our numerical simulations match closely the lateral spread observed by the M3 in the ocean water column. Finally, we compared the seep model predictions for the acoustic properties of these natural seep plumes with that observed by the acoustic instruments in the field. The M3 and EM 302 observations were converted to relative values of target strength using a calibration we obtained in the laboratory for the M3 and using an algorithm from the manufacturer for the EM 302. Comparing the numerical seep model to these data, we obtain good agreement over the whole height of rise of these bubble flares. This further validates the numerical model. Overall, our validated seep model captures the key dynamics of gas bubbles released from natural seeps in the oceans and helps to predict the fate of methane in the water column.

03 NATURAL GAS↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Automated Model for Improved Mapping of Country-Scale High-Resolution Coastal Bathymetry

Accurate and up-to-date maps of coastal bathymetry are critical for a variety of sectors from vessel navigation to port construction and are increasingly vital to inform coastal infrastructure management amid accelerating sea-level rise and more frequent and severe storm-surge events. The primary challenges to accurate and efficient bathymetric mapping from optical remote sensing are: accurately modeling light attenuation in both the atmosphere and water column; and inefficient data processing pipelines for highresolution satellite imagery. To address the effects of light attenuation within the water-column we have developed a novel physics-based bathymetry model that accounts for variations in water-column inherent optical properties on a pixel-by-pixel basis in optically-shallow aquatic environments, which represents a major advancement. For applications to satellite imagery, we have developed a software package that automatically applies the robust 6S atmospheric correction algorithm, estimates the bottom depth from the physics-based bathymetry model, which corrects for attenuation by suspended particulate matter and colored dissolved organic matter in the water column on a pixel-by-pixel basis, and leverages highperformance computing for rapid application to region-scale (e.g., CONUS) 2-meter resolution imagery datasets. Our approach is tailored to sensors that collect data at two-meter resolution with high return times for frequent updates. We mapped 591 WorldView satellite images for Florida, North Carolina, and Alaska and validated the maps against LiDAR-derived bathymetry data. Results show median RMSE of 1.75, 1.59, and 2.67 meters, respectively. By combining the strengths of Oak Ridge National Laboratory in high-performance computing and remote-sensing science with the water-column modeling expertise of Scripps Institution of Oceanography we advance the state of bathymetric mapping capability.

54 ENVIRONMENTAL SCIENCES↗

LITERATURE REVIEWS TO SUPPORT ION EXCHANGE TECHNOLOGY SELECTION FOR MODULAR SALT PROCESSING

This report summarizes the results of literature reviews conducted to support the selection of a cesium removal technology for application in a small column ion exchange (SCIX) unit supported within a high level waste tank. SCIX is being considered as a technology for the treatment of radioactive salt solutions in order to accelerate closure of waste tanks at the Savannah River Site (SRS) as part of the Modular Salt Processing (MSP) technology development program. Two ion exchange materials, spherical Resorcinol-Formaldehyde (RF) and engineered Crystalline Silicotitanate (CST), are being considered for use within the SCIX unit. Both ion exchange materials have been studied extensively and are known to have high affinities for cesium ions in caustic tank waste supernates. RF is an elutable organic resin and CST is a non-elutable inorganic material. Waste treatment processes developed for the two technologies will differ with regard to solutions processed, secondary waste streams generated, optimum column size, and waste throughput. Pertinent references, anticipated processing sequences for utilization in waste treatment, gaps in the available data, and technical comparisons will be provided for the two ion exchange materials to assist in technology selection for SCIX. The engineered, granular form of CST (UOP IE-911) was the baseline ion exchange material used for the initial development and design of the SRS SCIX process (McCabe, 2005). To date, in-tank SCIX has not been implemented for treatment of radioactive waste solutions at SRS. Since initial development and consideration of SCIX for SRS waste treatment an alternative technology has been developed as part of the River Protection Project Waste Treatment Plant (RPP-WTP) Research and Technology program (Thorson, 2006). Spherical RF resin is the baseline media for cesium removal in the RPP-WTP, which was designed for the treatment of radioactive waste supernates and is currently under construction in Hanford, WA. Application of RF for cesium removal in the Hanford WTP does not involve in-riser columns but does utilize the resin in large scale column configurations in a waste treatment facility. The basic conceptual design for SCIX involves the dissolution of saltcake in SRS Tanks 1-3 to give approximately 6 M sodium solutions and the treatment of these solutions for cesium removal using one or two columns supported within a high level waste tank. Prior to ion exchange treatment, the solutions will be filtered for removal of entrained solids. In addition to Tanks 1-3, solutions in two other tanks (37 and 41) will require treatment for cesium removal in the SCIX unit. The previous SCIX design (McCabe, 2005) utilized CST for cesium removal with downflow supernate processing and included a CST grinder following cesium loading. Grinding of CST was necessary to make the cesium-loaded material suitable for vitrification in the SRS Defense Waste Processing Facility (DWPF). Because RF resin is elutable (and reusable) and processing requires conversion between sodium and hydrogen forms using caustic and acidic solutions more liquid processing steps are involved. The WTP baseline process involves a series of caustic and acidic solutions (downflow processing) with water washes between pH transitions across neutral. In addition, due to resin swelling during conversion from hydrogen to sodium form an upflow caustic regeneration step is required. Presumably, one of these basic processes (or some variation) will be utilized for MSP for the appropriate ion exchange technology selected. CST processing involves two primary waste products: loaded CST and decontaminated salt solution (DSS). RF processing involves three primary waste products: spent RF resin, DSS, and acidic cesium eluate, although the resin is reusable and typically does not require replacement until completion of multiple treatment cycles. CST processing requires grinding of the ion exchange media, handling of solids with high cesium loading, and handling of liquid wash and conditioning solutions. RF processing requires handling and evaporation of cesium eluates, disposal of spent organic resin, and handling of the various liquid wash and regenerate solutions used. In both cases, the DSS will be immobilized in a low activity waste form. It appears that both technologies are mature, well studied, and generally suitable for this application. Technology selection will likely be based on downstream impacts or preferences between the various processing options for the two materials rather than on some unacceptable performance property identified for one material. As a result, the following detailed technical review and summary of the two technologies should be useful to assist in technology selection for SCIX.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Geochemical Characterization of Chromate Contamination in the 100 Area Vadose Zone at the Hanford Site

The major objectives of the proposed study were to: 1.) determine the leaching characteristics of hexavalent chromium [Cr(VI)] from contaminated sediments collected from 100 Area spill sites; 2.) elucidate possible Cr(VI) mineral and/or chemical associations that may be responsible for Cr(VI) retention in the Hanford Site 100 Areas through the use of i.) macroscopic leaching studies and ii.) microscale characterization of contaminated sediments; and 3.) provide information to construct a conceptual model of Cr(VI) geochemistry in the Hanford 100 Area vadose zone. In addressing these objectives, additional benefits accrued were: (1) a fuller understanding of Cr(VI) entrained in the vadose zone that will that can be utilized in modeling potential Cr(VI) source terms, and (2) accelerating the Columbia River 100 Area corridor cleanup by providing valuable information to develop remedial action based on a fundamental understanding of Cr(VI) vadose zone geochemistry. A series of macroscopic column experiments were conducted with contaminated and uncontaminated sediments to study Cr(VI) desorption patterns in aged and freshly contaminated sediments, evaluate the transport characteristics of dichromate liquid retrieved from old pipelines of the 100 Area; and estimate the effect of strongly reducing liquid on the reduction and transport of Cr(VI). Column experiments used the < 2 mm fraction of the sediment samples and simulated Hanford groundwater solution. Periodic stop-flow events were applied to evaluate the change in elemental concentration during time periods of no flow and greater fluid residence time. The results were fit using a two-site, one dimensional reactive transport model. Sediments were characterized for the spatial and mineralogical associations of the contamination using an array of microscale techniques such as XRD, SEM, EDS, XPS, XMP, and XANES. The following are important conclusions and implications. Results from column experiments indicated that most of contaminant Cr travels fast through the sediments and appears as Cr(VI) in the effluents. The significance of this for groundwater concentrations would, however, depend on the mass flux of recharge to the water table. adsorption of Cr(VI) to sediments from spiked Cr(VI) solution is low; calculated retardation coefficients are close to one. Calcium polysulfide solutions readily reduced Cr(VI) to Cr(III) in column experiments. However a significant amount of the Cr(VI) was mobilized ahead of the polysulfide solution front. This has significant implications for in-situ reductive remediation techniques. The experiments suggest that it would be difficult to design a remedial measure using infiltration of liquid phase reductants without increasing transport of Cr(VI) toward the water table. The microscopic characterization results are consistent with the column studies. Cr(VI) is found as ubiquitous coatings on sediment grain surfaces. Small, higher concentration, chromium sites are associated with secondary clay mineral inclusions, with occasional barium chromate minerals, and reduced to Cr(III) in association with iron oxides that are most likely magnetite primary minerals. Within the restricted access domains of sediment matrix, ferrous iron could also diffuse from in situ, high-surface-area minerals to cause the reductive immobilization of chromate. This process may be favored at microscale geochemical zones where ferrous iron could be supplied. Once nucleated, micrometer-scale precipitates are favored as growing locales for further accumulation, causing the formation of discrete zones of Cr(III).

54 ENVIRONMENTAL SCIENCES↗

Mitigating Sulfidogenesis With Simultaneous Perchlorate and Nitrate Treatments

Sulfide biogenesis (souring) in oil reservoirs is an extensive and costly problem. Nitrate is currently used as a souring inhibitor but often requires high concentrations and yields inconsistent results. Recently, perchlorate has displayed promise as a more potent inhibitor in lab scale studies. However, combining the two treatments to determine synergy and effectiveness in a dynamic system has never been tested. Nitrate inhibits perchlorate consumption by perchlorate reducing bacteria, suggesting that the combined treatment may allow deeper penetration of the perchlorate into the reservoir matrix. Furthermore, the metabolic intermediates of perchlorate and nitrate reduction (nitrite and chlorite, respectively) are synergistic with the primary electron acceptors for inhibition of sulfate reduction. To assess the possible synergies between nitrate and perchlorate treatments, triplicate glass columns packed with pre-soured marine sediment were flushed with media containing sulfate and an inhibitor treatment [(i) perchlorate; (ii) nitrate; (iii) perchlorate and nitrate; or (iv) none]. Internal geochemistry and microbial community changes were monitored along the length of the columns during six phases of increasing treatment concentrations. In a final phase all treatments were removed. Sulfide production decreased in all treated columns in conjunction with increased inhibitor concentrations relative to the untreated control. Interestingly, the potency of the "mixed" treatment was additive relative to the individual treatments suggesting no interaction. Microbial community analyses indicated community shifts and clustering by treatment. The mixed treatment column community's trajectory closely resembled that of the community found in the perchlorate only treatment, suggesting that perchlorate was the dominant control on the "mixed" community structure. In contrast, the nitrate and untreated column communities had unique trajectories. This study indicates that concurrent nitrate and perchlorate treatment is not more effective than perchlorate treatment alone but is more effective than nitrate treatment. As such, treatment decisions may be based on economic factors.

59 BASIC BIOLOGICAL SCIENCES↗

Comparative study of machine learning techniques for post-combustion carbon capture systems

Computational analysis of countercurrent flows in packed absorption columns, often used in solvent-based post-combustion carbon capture systems (CCSs), is challenging. Typically, computational fluid dynamics (CFD) approaches are used to simulate the interactions between a solvent, gas, and column's packing geometry while accounting for the thermodynamics, kinetics, heat, and mass transfer effects of the absorption process. These simulations can then be used explain a column's hydrodynamic characteristics and evaluate its CO 2 -capture efficiency. However, these approaches are computationally expensive, making it difficult to evaluate numerous designs and operating conditions to improve efficiency at industrial scales. In this work, we comprehensively explore the application of statistical ML methods, convolutional neural networks (CNNs), and graph neural networks (GNNs) to aid and accelerate the scale-up and design optimization of solvent-based post-combustion CCSs. We apply these methods to CFD datasets of countercurrent flows in absorption columns with structured packings characterized by several geometric parameters. We train models to use these parameters, inlet velocity conditions, and other model-specific representations of the column to estimate key determinants of CO 2 -capture efficiency without having to simulate additional CFD datasets. We also evaluate the impact of different input types on the accuracy and generalizability of each model. We discuss the strengths and limitations of each approach to further elucidate the role of CNNs, GNNs, and other machine learning approaches for CO 2 -capture property prediction and design optimization.

97 MATHEMATICS AND COMPUTING↗

Cloud Structure of Three Galactic Infrared Dark Star-forming Regions from Combining Ground- and Space-based Bolometric Observations

We have modified the iterative procedure introduced by Lin et al., to systematically combine the submillimeter images taken from ground-based (e.g., CSO, JCMT, APEX) and space (e.g., Herschel, Planck) telescopes. We applied the updated procedure to observations of three well-studied Infrared Dark Clouds (IRDCs): G11.11−0.12, G14.225−0.506, and G28.34+0.06, and then performed single-component, modified blackbody fits to each pixel to derive ∼10″ resolution dust temperature and column density maps. The derived column density maps show that these three IRDCs exhibit complex filamentary structures embedded with rich clumps/cores. We compared the column density probability distribution functions (N-PDFs) and two-point correlation (2PT) functions of the column density field between these IRDCs with several OB-cluster-forming regions. Based on the observed correlation between the luminosity-to-mass ratio and the power-law index of the N-PDF, and complementary hydrodynamical simulations for a 10{sup 4} M{sub ⊙} molecular cloud, we hypothesize that cloud evolution can be better characterized by the evolution of the (column) density distribution function and the relative power of dense structures as a function of spatial scales, rather than merely based on the presence of star-forming activity. An important component of our approach is to provide a model-independent quantification of cloud evolution. Based on the small analyzed sample, we propose four evolutionary stages, namely, cloud integration, stellar assembly, cloud pre-dispersal, and dispersed cloud. The initial cloud integration stage and the final dispersed cloud stage may be distinguished from the two intermediate stages by a steeper than −4 power-law index of the N-PDF. The cloud integration stage and the subsequent stellar assembly stage are further distinguished from each other by the larger luminosity-to-mass ratio (>40 L{sub ⊙}/M{sub ⊙}) of the latter. A future large survey of molecular clouds with high angular resolution may establish more precise evolutionary tracks in the parameter space of N-PDF, 2PT function, and luminosity-to-mass ratio.

79 ASTRONOMY AND ASTROPHYSICS↗

Single Particle Soot Photometer (SP2) BBOP

The SP2 provides information on the amounts of rBC (refractory black carbon) and of other, non-refractory substances associated with individual rBC containing particles by simultaneously measuring the scattering and incandescence signals of such particles that are directed through the cavity of a 1064 nm Nd:YAG laser. rBC concentration is reported at STP conditions Time resolution: 10 sec Uncertainty: ~ 25% SP2 unit used: 24 Calibration: Fullerene soot with variable mobility density. No correction for OC content in Fullerene (recent study on SP2 sensitivity to differing black carbon types reports that non-refractory material content for fullerene soot is about 20%). SP2_dateTime: UTC Mass equivalent diameters (SP2_min; SP2_geo; and SP2_max) are in units of micrometers dN/dLogDp counts (SP2_cnts_0...SP2_cnts_199) are in units of #/cc" rBC mass concentration is in units of ng/m3. Note that the rBC column length is one field shorter than the SP2_datetime column. Last time field is not relevant to the rBC time series (see comment below on length of SP2_datetime column) Lengths for SP2_max; SP2_min; SP2_geo are one field longer then the number of SP2_cnts_XX columns . This is to provide bounds for image plots (if desired). Length for SP2_datetime is one field longer than that length of the SP2_cnts_XX columns. This is to provide bounds for image plots (if desired)"

54 ENVIRONMENTAL SCIENCES↗

TRAILS Output Files

Overview This data repository contains ZIP files that store compressed versions of the output of running the WaterPaths utility planning and management tool in the DU Re-Evaluation mode (to download the tool, please see this GitHub repository). The tool was used to simulate the six-utility North Carolina Research Triangle problem. Details on the contents of each ZIP file can be seen below. Data details Temporal range: Weekly data for 2,344 weeks from 2015 to 2060 (45 years). Spatial range: Six water utilities in the North Carolina Research Triangle region (0: Chapel Hil/OWASA, 1: Durham, 2: Cary, 3: Raleigh, 4: Pittsboro, and 5: Chatham) File types: CSV and OUT Different solutions available The solution numbers correspond to the different pathway strategies (henceforth referred to as "solutions") discussed in paper's main and supporting text (abstract and link to the paper here). They are as follows: Sol92: The Durham-focused pathway strategy Sol132: The Raleigh-focused pathway strategy Sol140: The regionally-robust pathway strategy Objectives files These files can be accessed by unzipping solXX_objectives_pathways.zip that contains 1,000 Objectives_RDMXX_solsXX_to_XX.csv files. Each CSV file will consist of a row representing all the objective values for that specific solution, while every six columns represents the reliability, restriction frequency, infrastructure net present value ($ mil), peak financial cost, worst-case cost, and unit cost ($ per MG; in that order) for each of the six utilities. There will be 1,000 such files, denoting the performance of the six utilities across the 1,000 deeply uncertain states of the world (DU SOWs). Pathway files These files can be accessed by unzipping solXX_objectives_pathways.zip that contains 1,000 Pathways_sXX_RDMXX.out file. Each OUT corresponds to the set of infrastructure being triggered in a specific DU SOW, and each file will have the name file will consist of four tab-delimited columns that are described as follows: Realization: The realization in which an infrastructure options being triggered utility: The utility currently triggering infrastructure week: The week in which a specific infrastructure option is being triggered infra.: The infrastructure option being triggered If the OUT file contains only the header line, no infrastructure was triggered for that specific DU SOW. Policies files These files can be obtained by unzipping Policies.zip. Each of the 1,000 CSV files within the unzipped folder will contain weekly water use restriction policies for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: 0rest_m: restriction multiplier for utility 0 (values between 0 and 1) 1rest_m: restriction multiplier for utility 1 (values between 0 and 1) 2rest_m: restriction multiplier for utility 2 (values between 0 and 1) 3rest_m: restriction multiplier for utility 3 (values between 0 and 1) 4rest_m: restriction multiplier for utility 4 (values between 0 and 1) 5rest_m: restriction multiplier for utility 5 (values between 0 and 1) 0transf: transfer volume for utility 0 (in MGD) 1transf: transfer volume for utility 1 (in MGD) 2transf: transfer volume for utility 2 (in MGD) 3transf: transfer volume for utility 3 (in MGD) 4transf: transfer volume for utility 4 (in MGD) 5transf: transfer volume for utility 5 (in MGD) Water Sources files These files can be obtained by unzipping WaterSources_subset.zip. Each of the 100 CSV files within the unzipped folder will contain weekly state variables at each water source for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: Xvolume: available water volume from source X (in MGD) Xs_area: surface area of source X (in ACF) Xdemand: demand drawn from a water source from source X (in MGD) Xup_spill: upstream spillage from source X (in MGD) Xww_inflow: wastewater inflow from source X (in MGD) Xcatch_inflow: upstream catchment inflow to source X (in MGD) Xevap: evaporation multiplier for source X (values between 0 and 1) Xds_spill: downstream spillage from source X (in MGD) X_Y_alloc_cap: the allocated capacity from source X to utility Y (values between 0 and 1) X_Y_alloc_dem: the allocated demand from source X to utility Y (values between 0 and 1) Xtrmt_alloc_Y: the allocated treatment capacity from source X to utility Y (values between 0 and 1) Utilities files These files can be obtained by unzipping Utilities_subset.zip. Each of the 100 CSV files within the unzipped folder will contain weekly state variables at each utility for all 1,000 hydroclimatic realizations within a specific DU SOW. The column structure is as follows: Xst_vol: total available storage volume of utility X (in MG) Xcapacity: total storage capacity of utility X (in MG) Xnet_inf: : net inflow for all storage infrastructure for utility X (in MGD) Xst_rof: short term ROF for utility X (values between 0 and 1) Xst_stor_rof: short-term storage ROF for utility X (values between 0 and 1) Xst_trmt_rof: short-term treatment ROF for utility X (values between 0 and 1) Xlt_rof: long-term ROF for utility X (values between 0 and 1) Xlt_stor_rof: long-term storage ROF for utility X (values between 0 and 1) Xlt_trmt_rof: long-term treatment ROF for utility X (values between 0 and 1) Xrest_demand: restricted demand for utility X (in MGD) Xunrest_demand: unrestricted demand for utility X (in MGD) Xunfulf_demand: unfulfilled demand for utility X (in MGD) Xwastewater: wastewater return for utility X (in MGD) Xtreat_capacity: total treatment capacity for utility X (in MG) Xcont_fund: reserve (contingency) fund balance for utility X Xins_pout: insurance payout for utility X (% annual volumetric revenue) Xins_price: insurance price for utility X (% annual volumetric revenue) Xinfra_npv: infrastructure net present value for utility ($mil) Xst_vol: total available storage volume of utility X (in MG) Xdebt_serv: debt service for utility X (usually once per year if the infrastructure is triggered; % annual volumetric revenue) Xstor_vol: total stored volume (in MGD) Xobs_ann_dem: observed annual demand for utility X (in MGD) Xproj_dem: projected annual demand for utility X (in MGD) Xpv_debt_serv: present value of debt service payments for utility X (% annual volumetric revenue) Xgross_rev: gross revenue for utility X ($mil) Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program.

Artificial Intelligence↗

Optimal Design of Intensified Towers for CO2 Capture with Internal, Printed Heat Exchangers

Solvent-based carbon capture processes typically suffer from the temperature rise of the solvent due to the heat of absorption of CO2. This increased temperature is not thermodynamically favor-able and results in a significant reduction in performance in the absorber column. As opposed to interstage coolers, which only remove, cool, and return the solvent at discrete locations in the column, internal coolers that are integrated with the packing can cool the process inline, which can result in improved efficiency. This work presents the modeling of these internal coolers within an existing generic, equation-oriented absorber column model that can cool the process while allowing for simultaneous mass transfer. Optimization of this model is also performed, which is capable of optimally choosing the best locations to place these devices, such that heat removal and mass transfer area are balanced. Results of the optimization have shown that optimally placed cooling elements result in a significant increase in the capture efficiency of the process, compared to a similar column with no internal cooling, with a common trend being the cooling of the column in the temperature bulge region. It is observed that by optimally placing an internal cooler, the solvent flow rate can be decreased, and the CO2 lean loading can be increased while still maintaining the same efficiency. These process changes can lead to a substantial reduction in costs due to lower reboiler duty.

Summits, Stephen↗