Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “cleaning performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Streamlined Approach for Environmental Restoration (SAFER) Plan for Corrective Action Unit 114: Area 25 EMAD Facility Nevada Test Site, Nevada

This Streamlined Approach for Environmental Restoration (SAFER) Plan addresses the actions needed to achieve closure for Corrective Action Unit (CAU) 114, Area 25 EMAD Facility, identified in the Federal Facility Agreement and Consent Order (FFACO). Corrective Action Unit 114 comprises the following corrective action site (CAS) located in Area 25 of the Nevada Test Site: • 25-41-03, EMAD Facility This plan provides the methodology for field activities needed to gather the necessary information for closing CAS 25-41-03. There is sufficient information and process knowledge from historical documentation and investigations of similar sites regarding the expected nature and extent of potential contaminants to recommend closure of CAU 114 using the SAFER process. Additional information will be obtained by conducting a field investigation before selecting the appropriate corrective action for CAS 25-41-03. It is anticipated that the results of the field investigation and implementation of corrective actions will support a defensible recommendation that no further corrective action is necessary. If it is determined that complete clean closure cannot be accomplished during the SAFER, then a hold point will have been reached and the Nevada Division of Environmental Protection (NDEP) will be consulted to determine whether the remaining contamination will be closed under the alternative corrective action of closure in place. This will be presented in a closure report that will be prepared and submitted to NDEP for review and approval. The CAS will be investigated based on the data quality objectives (DQOs) developed on April 30, 2009, by representatives of NDEP and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office. The DQO process was used to identify and define the type, amount, and quality of data needed to determine and implement appropriate corrective actions for CAS 25-41-03. The following text summarizes the SAFER activities that will support the closure of CAU 114: • Perform site preparation activities (e.g., utilities clearances, radiological surveys). • Collect samples of materials to determine whether potential source material (PSM) is present that may cause the future release of a contaminant of concern to environmental media. • If no PSMs are present at the CAS, establish no further action as the corrective action. • If a PSM is present at the CAS, either: - Establish clean closure as the corrective action. The material to be remediated will be removed and disposed of as waste, or - Establish closure in place as the corrective action and implement the appropriate use restrictions. • Confirm the selected closure option is sufficient to protect human health and the environment.

54 ENVIRONMENTAL SCIENCES↗

Self-Cleaning Cathodes for Endurance to Chromium Poisoning

Chromium (Cr) poisoning remains a significant issue in long-term solid oxide fuel cell (SOFC) operation. While the addition of Cr in the interconnect and balance-of-plant (BOP) materials is effective in improving their resistance to oxidation, it also causes the deposition of resistive phases in the air electrode and thus cell performance loss. Previous work has investigated the mitigation of chromium deposition using getters, Cr diffusion resistant coatings, and more chromium-tolerant air electrode materials. However, these mitigation strategies merely postpone the degradation of performance due to Cr poisoning. Additionally, some strategies require the replacement of components, e.g., use of getters. Here we investigated a new, in-situ Cr poisoning mitigation strategy.

30 DIRECT ENERGY CONVERSION↗

LaAlO{sub 3}/Si capacitors: Comparison of different molecular beam deposition conditions and their impact on electrical properties

A study of the structural and electrical properties of amorphous LaAlO{sub 3} (LAO)/Si thin films fabricated by molecular beam deposition (MBD) is presented. Two substrate preparation procedures have been explored namely a high temperature substrate preparation technique-leading to a step and terraces surface morphology-and a chemical HF-based surface cleaning. The LAO deposition conditions were improved by introducing atomic plasma-prepared oxygen instead of classical molecular O{sub 2} in the chamber. An Au/Ni stack was used as the top electrode for its electrical characteristics. The physico-chemical properties (surface topography, thickness homogeneity, LAO/Si interface quality) and electrical performance (capacitance and current versus voltage and TunA current topography) of the samples were systematically evaluated. Deposition conditions (substrate temperature of 550 Degree-Sign C, oxygen partial pressure settled at 10{sup -6} Torr, and 550 W of power applied to the O{sub 2} plasma) and post-depositions treatments were investigated to optimize the dielectric constant ({kappa}) and leakage currents density (J{sub Gate} at Double-Vertical-Line V{sub Gate} Double-Vertical-Line = Double-Vertical-Line V{sub FB}- 1 Double-Vertical-Line ). In the best reproducible conditions, we obtained a LAO/Si layer with a dielectric constant of 16, an equivalent oxide thickness of 8.7 A, and J{sub Gate} Almost-Equal-To 10{sup -2}A/cm{sup 2}. This confirms the importance of LaAlO{sub 3} as an alternative high-{kappa} for ITRS sub-22 nm technology node.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

CSP Plant Optimization Study for the California Power Market (“CalCSP”) (Final Technical Report)

Concentrating Solar Power (CSP) with thermal energy storage offers a unique and strategic opportunity to support California’s clean energy transition. Unlike photovoltaic (PV) systems, CSP with thermal storage can generate electricity after sunset and during periods of high demand, making it a valuable complement to intermittent renewable resources. CSP also provides synchronous, inertia-contributing generation, long-duration storage, and flexible dispatch—capabilities increasingly important as thermal plants retire. This report summarizes the findings of the CSP Plant Optimization Study for the California Power Market or “CalCSP study,” which evaluated the technical, economic, environmental, and policy factors that influence the deployment of CSP technologies in California. The CalCSP study was conducted to assess how CSP can contribute to California’s long-term decarbonization goals while enhancing grid reliability, supporting local economic development, and making efficient use of land and transmission resources. It draws on detailed modeling of CSP performance and costs, site suitability analysis, policy reviews, and stakeholder engagement across utilities, regulators, developers, and community organizations. The analysis focuses on mature molten-salt tower technology and incorporates lessons learned from the global CSP fleet, distinguishing today’s CSP from earlier first-of-a-kind projects in the U.S. The findings support a more prominent role for CSP in California’s evolving clean energy landscape. With strategic planning, targeted policy support, and continued cost improvements, CSP can complement PV and batteries to deliver reliable, around-the-clock clean electricity—especially in areas with high solar resource and constrained grid capacity.

14 SOLAR ENERGY↗

H-Canyon Jumper Gasket Sealing Evaluation

H-Canyon Documented Safety Analysis approved December 2019 credits the leak integrity of H-Canyon (HCA) process tanks, piping, and jumpers in preventing the release of radioactive material in a post seismic environment. Demonstration of leak tightness capability for this equipment was achieved through substantial analytical effort. However, one potential weak point that affects leak integrity exists at the gasketed joint between Hanford Connectors (HC) and nozzles. Review of the HCA Crane Log over a three-year period indicates the HCs periodically leak. Savannah River National Laboratory (SRNL) was requested to perform gasket compression tests that evaluate gasket relaxation characteristics, i.e., creep, and provide improvements to the HC installation process that can reduce or eliminate the frequency of leaks at HCs. A HC torque value of 312 ft-lbf is the target value used because it is the minimum torque value, with 95% confidence, when an unlubricated HC is impacted for standard sealing period of 9 seconds. In the HCA pipe-jumper connections are installed remotely by using HCs. HCs inherently add to the uncertainty of a gasketed joint because a calibrated torque value cannot be applied. The gasket material is a special material made of asbestos-fiber impregnated with Teflon. This material has been used for decades and generally performs well but does leak intermittently as gaskets creep and preloaded torque is lost. Gasket types are either snap-ring (SR) or lampshade (LS). Both gasket types cover the same seating area. The SR gasket is designed to remain with the jumper when the jumper is removed leaving the nozzle faces clean of any debris. SR gaskets are initially installed when the jumper is fabricated. Changing gaskets is time consuming and the radioactive environment presents risks to personnel. When jumpers are removed LS gaskets could be used to better seal the connection to reduce down time and ALARA concerns. That is, an LS gasket would be remotely positioned over the nozzle and the HC reinstalled. Testing also included two situations not typical of plant operation. One situation was the use of the non-standard double-layered gaskets (DG), and the other situation was the use of a LS without removal of the installed SR gasket. The DG was used when the supply of LS gaskets ended, so that testing could continue. It was of interest to demonstrate this gasket’s creep response because the DG, which was two gaskets glued together, was thicker than the LS gasket and the thicker material was expected to elicit a greater creep characteristics. The second situation of using two gaskets together by installing an LS gasket without removing the installed gasket is not allowed by the ASME Codes. However, by demonstrating the creep history of such a gasket arrangement it could be considered as an option that could possibly seal a connection while significantly reducing operational down time and personnel risk. Forty tests were conducted, and the overall results demonstrate the initial applied force and how the gasket changes with time. The change in sealing force, in terms of torque, was then measured to obtain a force history as the gaskets creep. This report documents the results of those tests as well as the method used to perform the tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Processes to Open the Container and the Sample Catcher of the Hayabusa Returned Capsule in the Planetary Material Sample Curation Facility of JAXA

Japanese spacecraft Hayabusa, which returned from near-Earth-asteroid Itokawa, successfully returned its reentry capsule to the Earth, the Woomera Prohibited Area in Australia in Jun 13th, 2010, as detailed in another paper [1]. The capsule introduced into the Planetary Material Sample Curation Facility in the Sagamihara campus of JAXA in the early morning of June 18th. Hereafter, we describe a series of processes for the returned capsule and the container to recover gas and materials in there. A transportation box of the recovered capsule was cleaned up on its outer surface beforehand and introduced into the class 10,000 clean room of the facility. Then, the capsule was extracted from the box and its plastic bag was opened and checked and photographed the outer surface of the capsule. The capsule was composed of the container, a backside ablator, a side ablator, an electronic box and a supporting frame. The container consists of an outer lid, an inner lid, a frame for latches, a container and a sample catcher, which is composed of room A and B and a rotational cylinder. After the first check, the capsule was packed in a plastic bag with N2 again, and transferred to the Chofu campus in JAXA, where the X-ray CT instrument is situated. The first X-ray CT analysis was performed on the whole returned capsule for confirming the conditions of latches and O-ring seal of the container. The analysis showed that the latches of the container should have worked normally, and that the double Orings of the container seemed to be sealed its sample catcher with no problem. After the first X-ray CT, the capsule was sent back to Sagamihara and introduced in the clean room to exclude the electronic box and the side ablator from the container by hand tools. Then the container with the backside ablator was set firmly to special jigs to fix the lid of container tightly to the container and set to a milling machine. The backside ablator was drilled by the machine to expose heads of bolts, which combined the ablator to the outer lid of the container, and after the drilling had been finished, all the bolts were unscrewed and the backside ablator was removed from the container. Then, the container was sent to the Chofu X-ray facility again to examine in detail by a micro X-ray CT instrument in order to reconfirm that the condition of the latches of the lid of container was normal and that its double O-ring seemed to have been sealed after the last X-ray CT analysis.

Fujimura, A.↗

Microbial potentiometric sensor: A new approach to longstanding challenges

The underlying hypothesis of this study is that simple potentiometric measurements between sensing electrodes and a shared reference electrode - Microbial Potentiometric Sesnor (MPS) system - can be employed in a long-term, continuous mode of operation to resolve the spatial and temporal changes in environmental systems. To address the hypothesis, (1) a conceptual description of the MPS system and its postulated principle of operation are provided; (2) the MPS system performance is documented under controlled laboratory conditions; and (3) the capabilities of the MPS system are documented under quiescent and dynamic field condition. In a laboratory setting, the variability among different MPS signals was insignificant confirming the postulated high accuracy and reproducibility of the sensor performance. It also demonstrated statistically significant correlations with dissolved oxygen (DO) and oxidation-reduction potential (ORP) sensors, while showing capabilities of operating under anoxic and anaerobic conditions. Regardless of their locations in the model wetland system, three MPS sensors functioned without interruption and cleaning for a period >2 years, and thus demonstrating long-term durability of the MPS technology. In real batch-wastewater treatment facility, the deployed MPS system signals were able to describe the organic carbon trends and correlate with each treatment phase in a cycle. Data reproducibility and reliability exceeded the expectations better describing the carbon treatment levels than the DO and ORP sensors (p < 4.4 × 10 –162 vs phase adjusted p < 3.0 × 10 –58 ). While MPS signals correlate with specific parameters that describe the local process or environments, it is more prudent to employ both the magnitude and pattern of a composite signal like the MPS signal describe the change to reflect any shift in the local environment. Finally, when compared to a baseline pattern, this change in signal magnitude and pattern reveals important information that can be employed to tailor and optimize any condition or process which involves microorganisms.

47 OTHER INSTRUMENTATION↗

High Efficiency Si Photocathode Protected by Multifunctional GaN Nanostructures

Photoelectrochemical water splitting is a clean and environmentally friendly method for solar hydrogen generation. Its practical application, however, has been limited by the poor stability of semiconductor photoelectrodes. In this work, we demonstrate the use of GaN nanostructures as a multifunctional protection layer for an otherwise unstable, low-performance photocathode. The direct integration of GaN nanostructures on n + -p Si wafer not only protects Si surface from corrosion but also significantly reduces the charge carrier transfer resistance at the semiconductor/liquid junction, leading to long-term stability (>100 h) at a large current density (>35 mA/cm 2 ) under 1 sun illumination. The measured applied bias photon-to-current efficiency of 10.5% is among the highest values ever reported for a Si photocathode. Here given that both Si and GaN are already widely produced in industry, our studies offer a viable path for achieving high-efficiency and highly stable semiconductor photoelectrodes for solar water splitting with proven manufacturability and scalability.

36 MATERIALS SCIENCE↗

Next-generation electronics by co-design with chalcogenide materials

As Moore’s law approaches its limits, chalcogenides offer a promising route to next-generation computing and sensing, thanks to their topological, magnetoelectric, excitonic, and spintronic properties. Yet the same traits that make them appealing, e.g., exotic properties at monolayer thickness, clean van der Waals interfaces, and strong many-body effects, also heighten sensitivity to fabrication, hindering translation into scalable devices. Progress is further constrained by fragmented knowledge across synthesis, processing, and integration, and by the lack of systematic links between fabrication parameters and performance metrics. This Perspective examines key obstacles in controlling chalcogenide heterostructures and stresses the need for an integrated co-design framework, uniting materials growth, processing, and device architecture to accelerate practical technologies.

36 MATERIALS SCIENCE↗

An (ultra) high-vacuum compatible sputter source for oxide thin film growth

A miniaturised CF-38 mountable sputter source for oxide and metal thin film preparation with enhanced high-vacuum and ultra-high-vacuum compatibility is described. The all home-built sputtering deposition device allows a high flexibility also in oxidic sputter materials, suitable deposition rates for preparation of films in the nm- and the sub-monolayer regime and excellent reliability and enhanced cleanliness for usage in UHV chambers. For a number of technologically important – yet hardly volatile – materials, the described source represents a significant improvement over thermal deposition techniques like electron-beam- or thermal evaporation, as especially the latter are no adequate tool to prepare atomically clean layers of refractory oxide materials. Furthermore, it is superior to commercially available magnetron sputter devices, especially for applications, where highly reproducible sub-monolayer thin film preparation under very clean UHV conditions is required (e.g., for studying phase boundary effects in catalysis). The device in turn offers the usage of a wide selection of evaporation materials and special target preparation procedures also allow the usage of pressed oxide powder targets. To prove the performance of the sputter-source, test preparations with technologically relevant oxide components, comprising ZrO{sub 2} and yttrium-stabilized ZrO{sub 2}, have been carried out. A wide range of characterization methods (electron microscopy, X-ray photoelectron spectroscopy, low-energy ion scattering, atomic force microscopy, and catalytic testing) were applied to demonstrate the properties of the sputter-deposited thin film systems.

36 MATERIALS SCIENCE↗

2022 roadmap on 3D printing for energy

The energy transition is one of the main challenges of our society and therefore a major driver for the scientific community. To ensure a smart transition to a sustainable future energy scenario different technologies such as energy harvesting using solar cells or windmills and chemical storage in batteries, super-capacitors or hydrogen have to be developed and ultimately deployed. New fabrication approaches based on additive manufacturing and the digitalization of the industrial processes increase the potential to achieve highly efficient and smart technologies required to increase the competitiveness of clean energy technologies against fossil fuels. In this frame, the present roadmap highlights the tremendous potential of 3D printing as a new route to fully automate the manufacturing of energy devices designed as digital files. Additionally, this article gives numerous guidelines to maximize the performance and efficiency of the next generation of 3D printed devices for the energy transition while reducing the waste of critical raw materials. In particular, the paper is focused on the current status, present challenges and the expected and required advances of 3D printing for the fabrication of the most relevant energy technologies such as fuel cells and electrolysers, batteries, solar cells, super-capacitors, thermoelectric generators, chemical reactors and turbomachinery.

36 MATERIALS SCIENCE↗

Overview of SOFC Anode Interactions with Coal Gas Impurities

An overview of the results of SOFC anode interactions with phosphorus, arsenic, selenium, sulfur, antimony, and hydrogen chloride as single contaminants or in combinations is discussed. Tests were performed using both anode- and electrolyte-supported cells in synthetic and actual coal gas for periods greater than 1000 hours. Post-test analyses were performed to identify reaction products formed and their distribution, and compared to phases expected from thermochemical modeling. The ultimate purpose of this work is to establish maximum permissible concentrations for impurities in coal gas, to aid in the selection of appropriate coal gas clean-up technologies.

01 COAL, LIGNITE, AND PEAT↗

ANNUAL RADIOACTIVE WASTE TANK INSPECTION PROGRAM 2010

Aqueous radioactive wastes from Savannah River Site (SRS) separations and vitrification processes are contained in large underground carbon steel tanks. Inspections made during 2010 to evaluate these vessels and other waste handling facilities along with evaluations based on data from previous inspections are the subject of this report. The 2010 inspection program revealed that the structural integrity and waste confinement capability of the Savannah River Site waste tanks were maintained. All inspections scheduled per SRR-LWE-2009-00138, HLW Tank Farm Inspection Plan for 2010, were completed. Ultrasonic measurements (UT) performed in 2010 met the requirements of C-ESG-00006, In-Service Inspection Program for High Level Waste Tanks, Rev. 3, and WSRC-TR-2002-00061, Rev.6. UT inspections were performed on Tanks 30, 31 and 32 and the findings are documented in SRNL-STI-2010-00533, Tank Inspection NDE Results for Fiscal Year 2010, Waste Tanks 30, 31 and 32. A total of 5824 photographs were made and 1087 visual and video inspections were performed during 2010. Ten new leaksites at Tank 5 were identified in 2010. The locations of these leaksites are documented in C-ESR-G-00003, SRS High Level Waste Tank Leaksite Information, Rev.5. Ten leaksites at Tank 5 were documented during tank wall/annulus cleaning activities. None of these new leaksites resulted in a release to the environment. The leaksites were documented during wall cleaning activities and the waste nodules associated with the leaksites were washed away. Previously documented leaksites were reactivated at Tank 12 during waste removal activities.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrective Action Plan for Corrective Action Unit 562: Waste Systems, Nevada National Security Site, Nevada

This Corrective Action Plan has been prepared for Corrective Action Unit (CAU) 562, Waste Systems, in accordance with the Federal Facility Agreement and Consent Order (1996; as amended March 2010). CAU 562 consists of 13 Corrective Action Sites (CASs) located in Areas 2, 23, and 25 of the Nevada National Security Site. Site characterization activities were performed in 2009 and 2010, and the results are presented in Appendix A of the Corrective Action Decision Document for CAU 562. The scope of work required to implement the recommended closure alternatives is summarized. (1) CAS 02-26-11, Lead Shot, will be clean closed by removing shot. (2) CAS 02-44-02, Paint Spills and French Drain, will be clean closed by removing paint and contaminated soil. As a best management practice (BMP), asbestos tile will be removed. (3) CAS 02-59-01, Septic System, will be clean closed by removing septic tank contents. As a BMP, the septic tank will be removed. (4) CAS 02-60-01, Concrete Drain, contains no contaminants of concern (COCs) above action levels. No further action is required; however, as a BMP, the concrete drain will be removed. (5) CAS 02-60-02, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. As a BMP, the drain grates and drain pipe will be removed. (6) CAS 02-60-03, Steam Cleaning Drain, will be clean closed by removing contaminated soil. As a BMP, the steam cleaning sump grate and outfall pipe will be removed. (7) CAS 02-60-04, French Drain, was clean closed. Corrective actions were completed during corrective action investigation activities. (8) CAS 02-60-05, French Drain, will be clean closed by removing contaminated soil. (9) CAS 02-60-06, French Drain, contains no COCs above action levels. No further action is required. (10) CAS 02-60-07, French Drain, requires no further action. The french drain identified in historical documentation was not located during corrective action investigation activities. (11) CAS 23-60-01, Mud Trap Drain and Outfall, will be clean closed by removing sediment from the mud trap. As a BMP, the mud trap and outfall pipe will be removed. (12) CAS 23-99-06, Grease Trap, will be clean closed by removing sediment from the grease trap and backfilling the grease trap with grout. (13) CAS 25-60-04, Building 3123 Outfalls, will be clean closed by removing contaminated soil and the sludge-containing outfall pipe.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

NIF Maintenance Plan March 2011

Ensuring the reliability of the NIF, including its support systems and utilities, is essential to ensuring the availability of the NIF in its support of laser operations. This document identifies the policies and procedures necessary to perform and support the maintenance of the NIF’s systems. These systems are all encompassing and include the facility, beampath, Line Replaceable Units (LRUs), Safety Interlock System (SIS), and diagnostics and utilities that create the environments within the beampath consisting of vacuum, argon, or clean dry air.

42 ENGINEERING↗

Introducing Small Scale Waste-to-Energy Technology in Microgrids (Cooperative Research and Development Final Report, CRADA Number CRD-17-00703)

Cogent has developed an innovative, proprietary waste-to-energy (WTE) system, the HelioStorm(TM) Gasifier, capable of efficiently operating on small amounts of heterogeneous municipal solid waste feedstocks, converting them into a clean syngas that can be used to fuel an electricity generator, all with rapid on/off cycle times. NREL will work with Cogent to complete a computer simulation of an integrated HelioStorm(TM) plasma gasifier system and dual fuel diesel generator. Cogent will test the performance of an actual HelioStorm(TM) WTE system and dual fuel diesel generator at their test facility using steady state electrical loads and provide a report describing the performance of the integrated system.

09 BIOMASS FUELS↗

STOL propulsion systems

The selection and the characteristics of quiet, clean propulsion systems for STOL aircraft are discussed. Engines are evaluated for augmentor wing and externally blown flap STOL aircraft with the engines located both under and over the wings. Some supporting test data are presented. Optimum engines are selected based on achieving the performance, economic, acoustic, and pollution goals presently being considered for future STOL aircraft. The data and results presented were obtained from a number of contracted studies and some supporting NASA inhouse programs, most of which began in early 1972. The contracts include: (1) two aircraft and mission studies, (2) two propulsion system studies, (3) the experimental and analytic work on the augmentor wing, and (4) the experimental programs on Q-Fan. Engines are selected and discussed based on aircraft economics using the direct operating cost as the primary criterion. This cost includes the cost of the crew, fuel, aircraft, and engine maintenance and depreciation.

Denington, R. J.↗

Development of a Test Protocol for Spacecraft Post-Fire Atmospheric Cleanup and Monitoring

Detecting and extinguishing fires, along with post-fire atmospheric cleaning and monitoring, are vital components of a spacecraft fire response system. Preliminary efforts focused on the technology evaluation of these systems under realistic conditions are described in this paper. While the primary objective of testing is to determine a smoke mitigation filter s performance, supplemental evaluations measuring the smoke-filled chamber handheld commercial off-the-shelf (COTS) atmospheric monitoring devices (combustion product monitors) are also conducted. The test chamber consists of a 1.4 cubic meter (50 cu. ft.) volume containing a smoke generator. The fuel used to generate the smoke is a mixture of polymers in quantities representative of materials involved in a circuit board fire as a typical spacecraft fire. Two fire conditions were examined: no flame and flame. No flame events are produced by pyrolyzing the fuel mixture in a quartz tube furnace with forced ventilation to produce a white, lingering-type smoke. Flame events ignite the smoke at the outlet of the tube furnace producing combustion characterized by a less opaque smoke with black soot. Electrochemical sensor measurements showed carbon monoxide is a major indicator of each fire. Acid gas measurements were recorded, but cross interferents are currently uncharacterized. Electrochemical sensor measurements and sample acquisition techniques from photoacoustic sensors are being improved. Overall, this research shows fire characterization using traditional analytical chemistry techniques is required to verify measurements recorded using COTS atmospheric monitoring devices.

Zuniga, David↗