Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

In vivo visualization method by absolute blood flow velocity based on speckle and fringe pattern using two-beam multipoint laser Doppler velocimetry

Two-beam multipoint laser Doppler velocimetry (two-beam MLDV) is a non-invasive imaging technique able to provide an image of two-dimensional blood flow and has potential for observing cancer as previously demonstrated in a mouse model. In two-beam MLDV, the blood flow velocity can be estimated from red blood cells passing through a fringe pattern generated in the skin. The fringe pattern is created at the intersection of two beams in conventional LDV and two-beam MLDV. Being able to choose the depth position is an advantage of two-beam MLDV, and the position of a blood vessel can be identified in a three-dimensional space using this technique. Initially, we observed the fringe pattern in the skin, and the undeveloped or developed speckle pattern generated in a deeper position of the skin. The validity of the absolute velocity value detected by two-beam MLDV was verified while changing the number of layers of skin around a transparent flow channel. The absolute velocity value independent of direction was detected using the developed speckle pattern, which is created by the skin construct and two beams in the flow channel. Finally, we showed the relationship between the signal intensity and the fringe pattern, undeveloped speckle, or developed speckle pattern based on the skin depth. The Doppler signals were not detected at deeper positions in the skin, which qualitatively indicates the depth limit for two-beam MLDV.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Bearingless rotor aeromechanical stability measurements and correlations using nonlinear aerodynamics

The aeromechanical stability of a 1/8th Froude scaled bearingless rotor model was investigated experimentally in a wind tunnel. Both shaft-fixed and shaft-free conditions were examined to study the aeroelastic stability of a bearingless rotor without the incorporation of auxiliary dampers. This wind tunnel investigation generated a set of stability data for four different advance ratios, and a wide range of collective pitch settings. Theoretical analysis was performed using the newly developed University of Maryland Advanced Rotorcraft Code (UMARC). For analysis, the blade is modeled as an elastic beam undergoing flap bending, lag bending, elastic twist, and axial deformation. Blade response is calculated using a finite element method in time. Nonlinear aerodynamic effects are included by using a semiempirical stall modeling. The linearized periodic rotor perturbation equations in the nonrotating frame are solved for stability roots using Floquet transition matrix theory, as well as constant coefficient approximation. The predicted results are compared with the experimental data.

Wang, James M.↗

Note on quantitatively correct simulations of the kinetic beam-plasma instability

A large number of model particles are shown necessary for quantitatively correct simulations of the kinetic beam-plasma instability with the clouds-in-cells method. The required number of particles scales inversely with the expected growth rate, as only a narrow interval of beam velocities is resonant with the wave in the kinetic regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-E-T-459: Dosimetric Consequences of Rotated Elliptical Proton Spots in Modeling In-Air Proton Fluence for Calculating Doses in Water of Proton Pencil Beams

Purpose: We present a study of dosimetric consequences on doses in water in modeling in-air proton fluence independently along principle axes for rotated elliptical spots. Methods: Phase-space parameters for modeling in-air fluence are the position sigma for the spatial distribution, the angle sigma for the angular distribution, and the correlation between position and angle distributions. Proton spots of the McLaren proton therapy system were measured at five locations near the isocenter for the energies of 180 MeV and 250 MeV. An elongated elliptical spot rotated with respect to the principle axes was observed for the 180 MeV, while a circular-like spot was observed for the 250 MeV. In the first approach, the phase-space parameters were derived in the principle axes without rotation. In the second approach, the phase space parameters were derived in the reference frame with axes rotated to coincide with the major axes of the elliptical spot. Monte-Carlo simulations with derived phase-space parameters using both approaches to tally doses in water were performed and analyzed. Results: For the rotated elliptical 180 MeV spots, the position sigmas were 3.6 mm and 3.2 mm in principle axes, but were 4.3 mm and 2.0 mm when the reference frame was rotated. Measured spots fitted poorly the uncorrelated 2D Gaussian, but the quality of fit was significantly improved after the reference frame was rotated. As a Result, phase space parameters in the rotated frame were more appropriate for modeling in-air proton fluence of 180 MeV protons. Considerable differences were observed in Monte Carlo simulated dose distributions in water with phase-space parameters obtained with the two approaches. Conclusion: For rotated elliptical proton spots, phase-space parameters obtained in the rotated reference frame are better for modeling in-air proton fluence, and can be introduced into treatment planning systems.

07 ISOTOPE AND RADIATION SOURCES↗

Analytical calculation of central-axis dosimetric data for a dedicated 6-MV radiosurgery linear accelerator

Narrow beams are extensively used in stereotactic radiosurgery. The accuracy of treatment planning dose calculation depends largely on how well the dosimetric data are measured during the machine commissioning. Narrow beams are characterized by the lack of lateral electronic equilibrium. The lateral electronic disequilibrium in the radiation field and detector's finite size are likely to compromise the accuracy in dose measurements in these beams. This may have a profound impact on outcome in patients who undergo stereotactic radiosurgery. To confirm the measured commissioning data for a dedicated 6-MV linear accelerator-based radiosurgery system, we developed an analytical model to calculate the narrow photon beam central-axis dose. This model is an extension of a previously reported method of Nizin and Mooij for the calculation of the absorbed dose under lateral electronic disequilibrium conditions at depth of d{sub max} or greater. The scatter factor and tissue-maximum ratio were calculated for narrow beams using the parametrized model and compared to carefully measured results for the same beams. For narrow beam radii ranging from 0.2 to 1.5 cm, the differences between the analytical and measured scatter factors were no greater than 1.4%. In addition, the differences between the analytical and measured tissue-maximum ratios were within 3.3% for regions greater than the maximum dose depth. The estimated error of this analytical calculation was less than 2%, which is sufficient to validate measurement results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shell Closure N = 16 in {sup 24}O

Advanced nuclear structure models predict the presence of the shell closures N = 14, 16 in neutron-rich O isotopes rather than N = 20. Spectroscopic investigations performed at the neutron drip line have recently confirmed such predictions showing that the {sup 24}O is a doubly magic nucleus (Z = 8, N = 16). Predictions within the shell model calculation for the {sup 23,24}O ground state have been confirmed measuring their spectroscopic factors. Results obtained in one-neutron removal reactions performed by using in-flight radioactive ion beams produced at the Fragment Separator FRS of GSI are reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Polarised Drell-Yan measurements at COMPASS-II

The spin structure of the nucleon and its Parton Distribution Functions (PDFs) are important topics studied by the COMPASS experiment at CERN. So far, the transverse momentum dependent PDFs (TMD PDFs) of the proton and deuteron have been studied in Semi-Inclusive Deep Inelastic Scattering (SIDIS). The Drell-Yan (DY) process is a complementary way to access the TMD PDFs, using a transversely polarised target. Studying the angular distributions of dimuons from the DY events produced in the collisions of a π{sup −} beam with 190 GeV/c momentum off a transversely polarised proton target (NH{sub 3}) we are able to extract the azimuthal spin asymmetries, which are generated by 4 out of the 8 TMD PDFs needed to describe the nucleon structure at leading order QCD. The expected sign change in Sivers and Boer-Mulders functions when accessed from DY and SIDIS will be checked [1]. The opportunity to study, in the same experiment, the TMD PDFs from both SIDIS and DY processes is unique at COMPASS. The COMPASS II Proposal [2] was approved by CERN including one year for polarised DY measurements; the beginning of the DY data taking is scheduled for 2014. The feasibility of the measurement was proven by several beam tests performed so far.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

QCD equation of state at finite chemical potentials for relativistic nuclear collisions

In this work, we review the equation of state of QCD matter at finite densities. We discuss the construction of the equation of state with net baryon number, electric charge, and strangeness using the results of lattice QCD simulations and hadron resonance gas models. Its application to the hydrodynamic analyses of relativistic nuclear collisions suggests that the interplay of multiple conserved charges is important in the quantitative understanding of the dense nuclear matter created at lower beam energies. Several different models of the QCD equation of state are discussed for comparison.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Physics-constrained machine learning for electrodynamics without gauge ambiguity based on Fourier transformed Maxwell’s equations

We utilize a Fourier transformation-based representation of Maxwell’s equations to develop physics-constrained neural networks for electrodynamics without gauge ambiguity, which we label the Fourier–Helmholtz–Maxwell neural operator method. In this approach, both of Gauss’s laws and Faraday’s law are built in as hard constraints, as well as the longitudinal component of Ampère–Maxwell in Fourier space, assuming the continuity equation. An encoder–decoder network acts as a solution operator for the transverse components of the Fourier transformed vector potential, $\hat{A}_⟂(k,t)$, whose two degrees of freedom are used to predict the electromagnetic fields. This method was tested on two electron beam simulations. Among the models investigated, it was found that a U-Net architecture exhibited the best performance as it trained quicker, was more accurate and generalized better than the other architectures examined. We demonstrate that our approach is useful for solving Maxwell’s equations for the electromagnetic fields generated by intense relativistic charged particle beams and that it generalizes well to unseen test data, while being orders of magnitude quicker than conventional simulations. We show that the model can be re-trained to make highly accurate predictions in as few as 20 epochs on a previously unseen data set.

97 MATHEMATICS AND COMPUTING↗

Applications of an Energy Transfer Model to Three Problems in Planetary Regoliths: The Solid-State Greenhouse, Thermal Beaming, and Emittance Spectra

Several problems of interest in planetary infrared remote sensing are investigated using a new radiative-conductive model of energy transfer in regoliths: the solid-state greenhouse effect, thermal beaming, and reststrahlen spectra. The results of the analysis are as follows: (1) The solid-state greenhouse effect is self-limiting to a rise of a few tens of degrees in bodies of the outer solar system. (2) Non-Lambertian directional emissivity can account for only about 20% of the observed thermal beaming factor. The remainder must have another cause, presumably surface roughness effects. (3) The maximum in a reststrahlen emissivity spectrum does not occur exactly at the Christiansen wavelength where, by definition, the real part of the refractive index equals one, but rather at the first transition minimum in reflectance associated with the transition from particle scattering being dominated by volume scattering to that dominated by strong surface scattering. The transparency feature is at the second transition minimum and does not require the presence of a second band at longer wavelength for its occurance. Subsurface temperature gradients have only a small effect on emissivity bands.

Hapke, Bruce↗

Quantum vacuum processes in the extremely intense light of relativistic plasma mirror sources

Abstract The advent of petawatt-class laser systems allows generating electromagnetic fields of unprecedented strength in a controlled environment, driving increasingly more efforts to probe yet unobserved processes through their interaction with the quantum vacuum. Still, the lowest intensity scale governing these effects lies orders of magnitude beyond foreseen capabilities, so that such endeavor is expected to remain extremely challenging. In recent years, however, plasma mirrors have emerged as a promising bridge across this gap, by enabling the conversion of intense infrared laser pulses into coherently focused Doppler harmonic beams lying in the X-UV range. In this work, we present predictions on the quantum vacuum signatures produced when such beams are focused to intensities between 10 24 and 10 28 W cm −2 , specifically photon–photon scattering and electron–positron pair creation. These signatures are computed via the stimulated vacuum formalism, combined with a model of perfectly focused beam built from PIC-generated harmonics spectra, and implemented on state-of-the-art massively parallel numerical tools. In view of identifying experimentally favorable configurations, we also consider the coupling of the focused harmonic beam with an auxiliary optical beam, and provide comparison with other established schemes. Our results show that a single coherently focused harmonic beam can produce as much scattered photons as two infrared pulses in head-on collision, and confirm that the coupling of the harmonic beam to an auxiliary beam gives rise to significant levels of inelastic scattering, and hence holds the potential to strongly improve the attainable signal to noise ratios in experiments.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

MPRAD: A Monte Carlo and ray-tracing code for the proton radiography in high-energy-density plasma experiments

Proton radiography is used in various high-energy-density (HED) plasma experiments. In this paper, we describe a Monte Carlo and raytracing simulation tool called multimegaelectronvolt proton radiography (MPRAD) that can be used for modeling the deflection of proton beams in arbitrary three dimensional electromagnetic fields as well as the diffusion of the proton beams by Coulomb scattering and stopping power. Specifically, the Coulomb scattering and stopping power models in cold matter and fully ionized plasma are combined using interpolation. We discuss the application of MPRAD in a few setups relevant to HED plasma experiments where the plasma density can play a role in diffusing the proton beams and affecting the prediction and interpretation of the proton images. It is shown how the diffusion due to plasma density can affect the resolution and dynamical range of the proton radiography.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low and High Temperature Combustion Chemistry of Butanol Isomers in Premixed Flames and Autoignition Systems

Butanol is a fuel that has been proposed as a bio-derived alternative to conventional petroleum derived fuels. The structural isomer in traditional 'bio-butanol' fuel is n-butanol, but newer conversion technologies produce iso-butanol as a fuel. In order to better understand the combustion chemistry of bio-butanol, this study presents a comprehensive chemical kinetic model for all the four isomers of butanol (e.g., 1-, 2-, iso- and tert-butanol). The proposed model includes detailed high temperature and low temperature reaction pathways. In this study, the primary experimental validation target for the model is premixed flat low-pressure flame species profiles obtained using molecular beam mass spectrometry (MBMS). The model is also validated against previously published data for premixed flame velocity and n-butanol rapid compression machine and shock tube ignition delay. The agreement with these data sets is reasonably good. The dominant reaction pathways at the various pressures and temperatures studied are elucidated. At low temperature conditions, we found that the reaction of alphahydroxybutyl with O{sub 2} was important in controlling the reactivity of the system, and for correctly predicting C{sub 4} aldehyde profiles in low pressure premixed flames. Enol-keto isomerization reactions assisted by HO{sub 2} were also found to be important in converting enols to aldehydes and ketones in the low pressure premixed flames. In the paper, we describe how the structural features of the four different butanol isomers lead to differences in the combustion properties of each isomer.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Accessing the Sign and Magnitude of {delta}g via high P{sub T}, A{sub LL}{sup {pi}{sup {+-}}} in Polarized p+p Collisions at PHENIX

The double-helicity asymmetries (A{sub LL}) of {pi}{sup +} and {pi}{sup -} production in polarized proton proton collisions are specially interesting probes of the gluon's polarization. Relative differences among A{sub LL} of positive, neutral, and negative pions at high transverse momentum are sensitive to the sign and of magnitude of {delta}g. Quark-gluon (qg) scattering starts to dominate mid-rapidity pion production at RHIC at transverse momenta above 5 GeV/c. In this kinematic region the favored and unfavored fragmentation functions for each pion species are sensitive to both the gluon and the quark distributions, with different flavors having different weights for each pion species. Charged pion asymmetry measurements will be an important component in future global analyses, aiming to determine the gluon polarization over a wide range in x, the most recent results using polarized longitudinal data at {radical}(s) = 200 GeV, are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Kinetic modeling of solitary wave dynamics in a neutralizing ion beam

In this work, we characterize the formation and evolution of electrostatic solitary waves (ESWs) in the space-charge neutralization of ion beams using particle-in-cell simulations. These waves become excited when the electrons emitted from an external filament source initiate a two-stream instability in the beam. We show that such electrostatic waves become excited in both two-dimensional (2D) and three-dimensional (3D) beams with different shapes and sizes. Through a 1D Bernstein–Greene–Kruskal (BGK) analysis of the 2D beam, we find that the non-Maxwellian nature of the beam electrons gives rise to large-sized ESWs that are not predicted by BGK theory since it assumes a Maxwellian electron velocity distribution in the beam. Finally, we show that a 1D BGK theory is inadequate to describe ESWs in 3D beams because of complex electron trajectories.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SU-F-T-467: A Cross-Checking Approach for Dosimetric Verification of Beam- Matched Elekta Linear Accelerators

Purpose: To verify the similarity of the dosimetric characteristics between two Elekta linear accelerators (linacs) in order to treat patients interchangeably on these two machines without re-planning. Methods: To investigate the viability of matching the 6 MV flattened beam on an existing linac (Elekta Synergy with Agility head) with a recently installed new linca (Elekta Versa HD), percent depth doses (PDD), flatness and symmetry output factors were compared for both machines. To validate the beam matching among machines, we carried out two approaches to cross-check the dosimetrical equivalence: 1) the prior treatment plans were re-computed based on the newly built Versa HD treatment planning system (TPS) model without changing the beam control points; 2) The same plans were delivered on both machines and the radiation dose measurements on a MapCheck2 were compared with TPS calculations. Three VMAT plans (Head and neck, lung, and prostate) were used in the study. Results: The difference between the PDDs for 10×10 cm{sup 2} field at all depths was less than 0.8%. The difference of flatness and symmetry for 30×30 cm{sup 2} field was less than 0.8%, and the measured output factors varies by less than 1% for each field size ranging from 2×2 cm2 to 40×40 cm{sup 2}. For the same plans, the maximum difference of the two calculated dose distributions is 2% of prescription. For the QA measurements, the gamma index passing rates were above 99% for 3%/3mm criteria with 10% threshold for all three clinical plans. Conclusion: A beam modality matching between two Elekta linacs is demonstrated with a cross-checking approach.

43 PARTICLE ACCELERATORS↗