Measurements of a 2.1 MeV H$^-$ beam with an Allison scanner

Transverse 2D phase space distribution of a 2.1 MeV, 5 mA H$^-$ beam is measured at the PIPIT test accelerator at Fermilab with an Allison scanner. The paper describes the design, calibration, and performance of the scanner as well as the main results of the beam measurements. Analyses of the recorded phase portraits are performed primarily in action-phase coordinates; the stability of the action under linear optics makes it easier to compare measurements taken with different beamline conditions, e.g. in various locations. The intensity of a single measured point (\pixel") is proportional to the phase density in the corresponding portion of the beam. When the Twiss parameters are calculated using only the high-phase density part of the beam, the pixel intensity in the beam core is found to be decreasing exponentially with action and to be phase-independent. Outside of the core, the intensities decrease with action at a significantly slower rate than in the core. This `tail' comprises 10-30% of the beam, with 0.1% of the total measured intensity extending beyond the action 10-20 times larger than the rms emittance. The transition from the core to the tail is accompanied by the appearance of a strong phase dependence, which is characterized in action-phase coordinates by two `branches' extending beyond the core. A set of selected measurements shows, in part, that there is no measurable emittance dilution along the beam line in the main portion of the beam; the beam parameters are practically constant over a 0.5 ms pulse; and scraping in various parts of the beam line is an effective way to decrease the transverse tails by removing the branches.

43 PARTICLE ACCELERATORS↗

DEVELOPMENT OF A 300 KV DC HIGH VOLTAGE PHOTOGUN AND BEAM BASED STUDIES OF ALKALI NTIMONIDE PHOTOCATHODES

To advance magnetized gun research in the United States, a compact DC high voltage photogun with inverted-insulator geometry was designed, built, and operated reliably at 300 kV bias voltage using alkali-antimonide photocathodes. This photogun will provide a magnetized electron beam for the future Jefferson Lab Electron-Ion Collider (JLEIC) cooler. This research describes key electrostatic design features of the photogun and evaluates the performance of the in-house fabricated photocathodes and the quality of the electron beams. The thermal emittance of the electron beam was measured with various conditions: differ?ent gun bias voltages, different laser spot sizes, and photocathodes with different substrate materials. It has been hypothesized that the photocathode surface roughness affects the quality of the photocathodes and the electron beam produced, which is directly related to the thickness of the antimony layer of the photocathode. This effect was studied experimen?tally for both the beam emittance and photocathode quantum efficiency lifetime, and the measurements indicate that the beam emittance is largely independent of the antimony layer thickness, and the lifetime benefits from a thick layer. The ion bombardment always poses a problem for the photocathodes during high current beam operations. An effective way to repel the beam-induced ions was identified and implemented, and a sustainable 28 mA beam was achieved from the gun. This thesis presents a good performance of the photogun, a remarkable quantum efficiency lifetime of the photocathodes and a low emittance of the electron beam.

Wang, Yan↗

Beam dynamics corrections in the measurement of the anomalous precession frequency at the Muon $g-2$ experiment at Fermilab

The Muon $g-2$ experiment at Fermilab (E989) aims to measure the anomalous magnetic moment of the muon with an accuracy of 140 ppb (parts per billions). This accuracy, obtained by adding in quadrature a statistical and a systematic contribution of comparable value (100 ppb), will allow to reduce the experimental uncertainty (from the previous E821 experiment at BNL \cite{bnl}) of a factor of 4, and represents one of the most precise tests of the Standard Model (SM) theory of elementary particles. The first result on the Run-1 dataset \cite{prl} was released on April 7, 2021, showing a very good agreement with the previous result from BNL experiment, with a slightly better uncertainty. The corresponding experimental average increases the significance of the discrepancy between the measured and Standard Model prediction of 4.2$\sigma$ \cite{white_paper}.\\ \noindent The measured quantity is the muon magnetic anomaly a$_\mu$=$\frac{g_\mu-2}{2}$ where g$_\mu$ is the gyromagnetic factor of the muon. Dirac's equation predicts g$_\mu$ = 2, while radiative corrections, dominated by the QED contribution due to an exchange of a virtual photon, causes a per-mille correction on this quantity. By including all the SM contributions, a$_\mu$ is known at 370 ppb. The E989 experiment measures $a_\mu$ injecting positive muons with momentum of 3.1 GeV/$c$ polarized longitudinally in bunches (called $fills$) with an average rate of 12 Hz, in a storage ring of 14 meters diameter. Due to the parity violation in the weak muon decay, high energy positrons produced are emitted preferably in the muon's spin direction. By counting the number of positrons with energy greater then 1.7 GeV in function of the time, the frequency precession of the muon spin is measured, that together with the measurement of the magnetic field, allows to extract $a_\mu$. The positrons are detected with 24 electromagnetic calorimeters, that measure the energy and the arrival time of the positrons, each made of 54 crystals of lead fluoride (PbF$_2$) read by silicon photomultipliers (SiPM). Together with calorimeters, two tracking detectors are used to make non-destructive measurements of the muon beam characteristic by reconstructing the muon decay position extrapolating backward the decay positrons. The knowledge of the beam motion inside the ring plays a fundamental role in the analysis of $a_{\mu}$, where the measured anomalous precession frequency $\omega_a$ must be corrected for four main beam dynamics effects. A first correction is associated with the presence of an electric field responsible of the vertical focusing on the storage ring, where vertical direction is orthogonal to the orbit and horizontal direction is along the storage ring radius. Due to the oscillations in the vertical direction, the so called vertical betatron oscillations, a second correction is necessary to account for an average angle associated with the muon motion off the ideal orbit. A third correction is caused by lost muons in the ring which have a different spin phase at the injection respect to the decay ones. Finally, due to the correlation between the vertical and horizontal beam motion of the muons and the acceptance of the calorimeter, a correction (called ``phase-acceptance") arises. In Run1, due to the presence of two damaged resistors in one electrostatic quadrupole, this correction had a prominent role. The replacement of the damaged resistors before Run2 decreased this effect by one order of magnitude, and a further reduction in Run-3 was provided by an improved orbit.\\ \noindent The work of this Thesis focuses on the beam dynamics corrections on $\omega_a$. Due to the prominent role in Run-1 a special attention has been put to the phase-acceptance correction\footnote{The effect of this correction on the E821 BNL measurement of the $g-2$ has been evaluated to be within the quoted systematic error.}. Chapter \ref{ch:anomalous_magnetic_moment} introduces the anomalous magnetic moment of the muon. Chapter \ref{ch:early_experiment} describes the history of the Muon $g-2$ experiments. Chapter \ref{ch:theory} discusses the Standard Model prediction and possible new physics scenario. Chapter \ref{ch:muon_g2_experiment} describes the E989 experiment, whose experimental technique and the apparatus are discussed focusing on the improvements needed to reach the final goal on $a_\mu$ measurement. The original work of the Thesis is discussed in the last 5 chapters. Chapter \ref{ch:experiment_technique} presents the analysis technique to extract $\omega_a$, Chapter \ref{ch:beam_dynamics} describes the beam dynamics in the E989 experiment, Chapter \ref{ch:beam_dynamics_correction} discusses the beam dynamics correction to $\omega_a$, and Chapter \ref{sec:pa_corr} focuses on the phase acceptance correction. Finally Chapter \ref{ch:run23_analysis_improvements} contains the Run-2/3 improvements which are expected to allow for an increased precision ons the beam dynamics co...

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

European research activities on charge state breeding related to radioactive ion beam facilities (invited)

European effort on charge breeders is mainly dedicated to present and future Radioactive Ion Beam facilities. The main projects are High Intensity and Energy-ISOLDE at CERN, SPIRAL2 at GANIL, and EURISOL. Most of the experimental developments are funded by the European programs EURONS (European Nuclear Structure) and EURISOL (European Isotope Separation On-Line Radioactive Ion Beam Facility). Two ion source types (electron beam ion source and electron cyclotron resonance ion source) have been adapted to accept the injection and the capture of an ion beam, in order to increase its charge with the highest efficiency within the shortest time. Both charge breeders have advantages and disadvantages with regard to their use in a Radioactive Ion Beam facility. The most important parameters studied are acceptance (in emittance and intensity) of the charge breeder, efficiency, and charge breeding time of a specific n+ charge state, emittance of the extracted n+ beam. The charge breeder parameters are studied with different 1+ ion sources dedicated to 1+ radioactive ion beam production, and the tuning procedure of the charge breeder as a beam line section of a specific accelerator is established and measured too.

43 PARTICLE ACCELERATORS↗

Optimization of the beam extraction systems for the Linac4 H{sup −} ion source

The development of the Linac 4 and its integration into CERN’s acceleration complex is part of the foreseen luminosity upgrade of the Large Hadron Collider (LHC). The goal is to inject a 160 MeV H{sup −} beam into the CERN PS Booster (PSB) in order to increase the beam brightness by a factor of 2 compared to the 50 MeV proton linac, Linac 2, that is currently in operation. The requirements for the ion source are a 45 keV H{sup −} beam of 80 mA intensity, 2 Hz repetition rate and 0.5 ms pulse length within a normalized rms-emittance of 0.25 mm· mrad. The previously installed beam extraction system has been designed for an H{sup −} ion beam intensity of 20 mA produced by an RF-volume source with an electron to H{sup −} ratio of up to 50. For the required intensity upgrades of the Linac4 ion source, a new beam extraction system is being produced and tested; it is optimized for a cesiated surface RF-source with a nominal beam current of 40 mA and an electron to H{sup −} ratio of 4. The simulations, based on the IBSIMU code, are presented. At the Brookhaven National Laboratory (BNL), a peak beam current of more than 100 mA was demonstrated with a magnetron H{sup −} source at an energy of 35 keV and a repetition rate of 2 Hz. A new extraction system is required to operate at an energy of 45 keV; simulation of a two stage extraction system dedicated to the magnetron is presented.

43 PARTICLE ACCELERATORS↗

Electron beam dynamics in the DARHT-II linear induction accelerator

The DARHT-II linear induction accelerator (LIA) accelerates a 2-kA electron beam to more than 17 MeV. The beam pulse has a greater than 1.5-microsecond flattop region over which the electron kinetic energy is constant to within 1%. The beam dynamics are diagnosed with 21 beam-position monitors located throughout the injector, accelerator, and after the accelerator exit, where we also have beam imaging diagnostics. We discuss the tuning of the injector and accelerator, and present data for the resulting beam dynamics. We discuss the tuning procedures and other methods used to minimize beam motion, which is undesirable for its application as a bremsstrahlung source for multi-pulse radiography of exlosively driven hydrodynamic experiments. We also present beam stability measurements, which we relate to previous stability experiments at lower current and energy.

43 PARTICLE ACCELERATORS↗

Future beam experiments in the magnetosphere with plasma contactors: The electron collection and ion emission routes

Experiments where a high-voltage electron beam emitted by a spacecraft in the low-density magnetosphere is used to probe the magnetospheric configuration could greatly enhance our understanding of the near-Earth environment. Their challenge, however, resides in the fact that the background magnetospheric plasma cannot provide a return current that balances the electron beam current without charging the spacecraft to such high potential that in practice prevents beam emission. In order to overcome this problem, a possible solution is based on the emission of a high-density contactor plasma by the spacecraft prior to and after the beam. In this paper, we perform particle-in-cell simulations to investigate the conditions under which a high-voltage electron beam can be emitted from a magnetospheric spacecraft, comparing two possible routes that rely on the high-density contactor plasma. The first is an “electron collection” route, where the contactor has lower current than the electron beam and is used with the goal of connecting to the background plasma and collecting magnetospheric electrons over a much larger area than that allowed by the spacecraft alone. The second is an “ion emission” route, where the contactor has higher current than the electron beam. Ion emission is then enabled over the large quasi-spherical area of the contactor cloud, thus overcoming the space charge limits typical of ion beam emission. Finally, our results indicate that the ion emission route offers a pathway for performing beam experiments in the low-density magnetosphere, while the electron collection route is not viable because the contactor fails to draw a large neutralizing current from the background.

79 ASTRONOMY AND ASTROPHYSICS↗

Gated Irradiation With Scanned Particle Beams

Purpose: To demonstrate mitigation of the interplay effects of scanned particle beams and residual target motion within a gating window by increased overlap of pencil beams. Methods and Materials: Lateral overlap was increased by increasing the pencil beam widths or by decreasing the distance between the pencil beams (scan grid). Longitudinal overlap was increased by reducing the distance between iso-range slices. For scanned carbon ion beams, simulation studies were performed and validated experimentally to determine the required parameters for different residual motion characteristics. The dose distributions were characterized by the maximal local deviations representing local over- and underdosage. Results: For residual lateral motion, the local deviations were <5% for 2, 4, and 7 mm residual motion within the gating window for a 2-mm scan grid and pencil beams of 10, 14, and 18 mm full width at half maximum, respectively. Decreasing the iso-range slice distance from 3 mm to 1 mm effectively mitigated {<=}10 mm water-equivalent range changes. Experimental data reproduced the simulation results. Conclusion: In charged particle therapy with a scanned beam, interplay effects between gated beam delivery and residual target motion can be decreased effectively by increasing the overlap between pencil beams laterally, as well as longitudinally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Formation of an ion beam in an elementary cell with inhomogeneous emission current density

A well-known Pierce solution that allows focusing a beam of charged particles using properly shaped electrodes outside the beam aperture is generalized to the case of an accelerating system with inhomogeneous emission current density. It is shown that the defocusing effect of the space charge can, in principle, be evenly compensated over the entire cross section of the beam. In contrast to the beam with a uniform emission current density, both the electric potential and the transverse electric field must be controlled along the beam boundary in order to eliminate the angular divergence. However, eliminating the angular spread evenly across the beam constitutes a mathematically ill-posed problem which needs to be solved with the use of one or another method of regularization. An alternative way of diminishing beam emittance is proposed for the beam where the emission current is uniform across the entire aperture except for a narrow beam edge layer and a simple formula for the Pierce electrodes is derived. Numerical simulation has proved the reasonable accuracy of our analytical theory.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adiabatic thermal equilibrium theory for periodically focused axisymmetric intense beam propagation

An adiabatic equilibrium theory is presented for an intense, axisymmetric charged-particle beam propagating through a periodic solenoidal focusing field. The thermal beam distribution function is constructed based on the approximate and exact invariants of motion, i.e., a scaled transverse Hamiltonian and the angular momentum. The approximation of the scaled transverse Hamiltonian as an invariant of motion is validated analytically for highly emittance-dominated beams and highly space-charge-dominated beams, and numerically tested to be valid for cases in between with moderate vacuum phase advances ({sigma}{sub v}<90 deg.). The beam root-mean-square (rms) envelope equation is derived, and the self-consistent nonuniform density profile is determined. Other statistical properties such as flow velocity, temperature, total emittance and rms thermal emittance, equation of state, and Debye length are discussed. Numerical examples are presented, illustrating the effects of the beam perveance, emittance, and rotation on the beam envelope and density distribution. Good agreement is found between theory and a recent high-intensity beam experiment performed at the University of Maryland Electron Ring [S. Bernal, B. Quinn, M. Reiser, and P. G. O'Shea, Phys. Rev. ST Accel. Beams 5, 064202 (2002)].

43 PARTICLE ACCELERATORS↗

Compact, accurate description of diagnostic neutral beam propagation and attenuation in a high temperature plasma for charge exchange recombination spectroscopy analysis

Charge exchange recombination spectroscopy on Alcator C-Mod relies on the use of the diagnostic neutral beam injector as a source of neutral particles which penetrate deep into the plasma. It employs the emission resulting from the interaction of the beam atoms with fully ionized impurity ions. To interpret the emission from a given point in the plasma as the density of emitting impurity ions, the density of beam atoms must be known. Here, an analysis of beam propagation is described which yields the beam density profile throughout the beam trajectory from the neutral beam injector to the core of the plasma. The analysis includes the effects of beam formation, attenuation in the neutral gas surrounding the plasma, and attenuation in the plasma. In the course of this work, a numerical simulation and an analytical approximation for beam divergence are developed. The description is made sufficiently compact to yield accurate results in a time consistent with between-shot analysis.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutralization efficiency estimation in a neutral beam source based on inductively coupled plasma

This study examined the optimal conditions of neutral beam generation to maintain a high degree of neutralization and focusing during beam energy variation for a neutral beam source based on inductively coupled plasma with a three-grid ion beam acceleration system. The neutral beam energy distribution was estimated by measuring the energy profiles of ions that 'survived' the neutralization after reflection. The energy measurements of the primary and reflected ions showed narrow distribution functions, each with only one peak. At higher beam energies, both the ratio of the ion energy loss to the primary energy and the degree of energy divergence decreased, confirming the precise alignment of the neutral beam. The neutralization efficiency of the neutral beam source with a three-grid acceleration system was found to be affected mainly by the beam angle divergence rather than by the particle translation energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion Beam Extraction from Large Bore 11 to 13 GHz ECR Ion Source with a Pair of Cylindrically Comb-Shaped Magnetic Fields

We have developed a large bore electron cyclotron resonance (ECR) ion source with cylindrically comb-shaped magnetic field configuration to realize high current density and comparatively large bore ion beam which can be used for beam processes under low pressure and low microwave power. It is found that the plasma confinement of cylindrically comb-shaped magnetic fields is more effective than that of simple multipole magnetic fields. We have constructed a large bore ion beam extractor and set to the ECR ion source. The electron density attained to 10{sup 17{approx}}{sup 18} m{sup -3} order, ion saturation current density is about 80{approx}100 A/m{sup 2} under low pressure 0.03 Pa and low microwave power 200 W. We conduct the first trial of ion beam extraction from the ECR ion source. We investigate the ion beam characteristics for extraction voltages and Ar gas pressures. The extracted ion beam current increases in proportion to extraction voltages, however at present the beam current is lower than those estimated from ion saturation current. We observed the self-similar distribution of the extracted ion beam which is comparatively large bore. We are now investigating the ion beam extraction and going to optimize the electrode gap, the electrode position and shape of multi-holes of the extractor.

43 PARTICLE ACCELERATORS↗

Generalized Courant-Snyder theory and Kapchinskij-Vladimirskij distribution for high-intensity beams in a coupled transverse focusing lattice

The Courant-Snyder (CS) theory and the Kapchinskij-Vladimirskij (KV) distribution for high-intensity beams in an uncoupled focusing lattice are generalized to the case of coupled transverse dynamics. The envelope function is generalized to an envelope matrix, and the envelope equation becomes a matrix envelope equation with matrix operations that are noncommutative. In an uncoupled lattice, the KV distribution function, first analyzed in 1959, is the only known exact solution of the nonlinear Vlasov-Maxwell equations for high-intensity beams including self-fields in a self-consistent manner. The KV solution is generalized to high-intensity beams in a coupled transverse lattice using the generalized CS invariant. This solution projects to a rotating, pulsating elliptical beam in transverse configuration space. The fully self-consistent solution reduces the nonlinear Vlasov-Maxwell equations to a nonlinear matrix ordinary differential equation for the envelope matrix, which determines the geometry of the pulsating and rotating beam ellipse. These results provide us with a new theoretical tool to investigate the dynamics of high-intensity beams in a coupled transverse lattice. A strongly coupled lattice, a so-called N-rolling lattice, is studied as an example. It is found that strong coupling does not deteriorate the beam quality. Instead, the coupling induces beam rotation and reduces beam pulsation.

43 PARTICLE ACCELERATORS↗

Characteristics of ion-acoustic solitary wave in a laboratory dusty plasma under the influence of ion-beam

We study the influence of ion beam and charged dust impurity on the propagation of dust ion-acoustic solitary wave in an unmagnetized plasma consisting of Boltzmann distributed electrons, positive ions, positive ion beam, and negatively charged immobile dusts in a double plasma device. On interacting with an ion beam, the solitary wave is bifurcated into a compressive fast and a rarefactive slow beam mode, and appears along with the primary wave. However, there exists a critical velocity of the beam beyond which the amplitude of the fast solitary wave starts diminishing and rarefactive slow beam mode propagates with growing amplitude. Whereas, the presence of charged dust impurity in the plasma reduces this critical beam velocity and a substantial modification in the phase velocity of the slow beam mode is observed with increasing dust density. Furthermore, the nonlinear wave velocity (Mach number) as well as the width of the compressive solitons are measured for different beam velocity and dust density, and are compared with those obtained from the K-dV equation. The experimental results are found in a well agreement with the theoretical predictions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Enhanced relativistic self-focusing of Hermite-cosh-Gaussian laser beam in plasma under density transition

Enhanced and early relativistic self-focusing of Hermite-cosh-Gaussian (HChG) beam in the plasmas under density transition has been investigated theoretically using Wentzel-Kramers-Brillouin and paraxial ray approximation for mode indices m=0, 1, and 2. The variation of beam width parameter with normalized propagation distance for m=0, 1, and 2 is reported, and it is observed that strong self-focusing occurs as the HChG beam propagates deeper inside the nonlinear medium as spot size shrinks due to highly dense plasmas and the results are presented graphically. A comparative study between self-focusing of HChG beam in the presence and absence of plasmas density transition is reported. The dependency of beam width parameter on the normalized propagation distance for different values of decentered parameter “b” has also been presented graphically. For m=0 and 1, strong self-focusing is reported for b=1.8, and for m=2 and b=1.8, beam gets diffracted. The results obtained indicate the dependency of the self-focusing of the HChG beam on the selected values of decentered parameter. Moreover, proper selection of decentered parameter results strong self-focusing of HChG beam. Stronger self-focusing of laser beam is observed due to the presence of plasma density transition which might be very useful in the applications like the generation of inertial fusion energy driven by lasers, laser driven accelerators, etc.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Studies of the beam extraction system of the GTS-LHC electron cyclotron resonance ion source at CERN

The 14.5 GHz GTS-LHC Electron Cyclotron Resonance Ion Source (ECRIS) provides multiply charged heavy ion beams for the CERN experimental program. The GTS-LHC beam formation has been studied extensively with lead, argon, and xenon beams with varied beam extraction conditions using the ion optical code IBSimu. The simulation model predicts self-consistently the formation of triangular and hollow beam structures which are often associated with ECRIS ion beams, as well as beam loss patterns which match the observed beam induced markings in the extraction region. These studies provide a better understanding of the properties of the extracted beams and a way to diagnose the extraction system performance and limitations, which is otherwise challenging due to the lack of direct diagnostics in this region and the limited availability of the ion source for development work.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation of a pulsed low-energy electron beam using the channel spark device

For the generation of low-energy electron beam, the design and characteristics of channel spark discharge (CSD) operating at a low voltage are presented in this paper. The discharge voltage, discharge current, X-ray emissions, and electron beam current were experimentally determined. The effects of the applied voltage, working gas pressure, and external capacitance on the CSD and beam parameters were measured. At an applied voltage of 11 kV, an oxygen gas pressure of 25 mTorr, and an external capacitance of 16.45 nF, the maximum measured current was 900 A. The discharge current increased with the increase in the pressure and capacitance, while its periodic time decreased with the increase in the pressure. Two types of the discharge were identified and recorded: the hollow cathode discharge and the conduction discharge. A Faraday cup was used to measure the beam current. The maximum measured beam current was 120 A, and the beam signal exhibited two peaks. The increase in both the external capacitance and the applied discharge voltage increased the maximum electron beam current. The electron-beam pulse time decreased with the increase in the gas pressure at a constant voltage and increased with the decrease in the applied discharge voltage. At an applied voltage of 11 kV and an oxygen gas pressure of 15 mTorr, the maximum beam energy was 2.8 keV. The X-ray signal intensity decreased with the increase in the gas pressure and increased with the increase in the capacitance.