Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VENTILATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Refrigerants for a Sustainable Future

Worldwide use of high global warming potential (GWP) hydrofluorocarbon (HFC) refrigerants for space conditioning and food storage results in significant equivalent greenhouse gas (GHG) emissions. This is further exacerbated in developed countries by the current transition from hydrochlorofluorocarbon (HCFC) refrigerants to HFC refrigerants. Under the Kigali amendment to the Montreal Protocol, the proposed phase-out of currently used HFC and HCFC refrigerants has initiated a re-evaluation of some pre-existing refrigerants as well as the development and evaluation of new refrigerants. Making the ideal refrigerant selections for heating, ventilation, air-conditioning, and refrigeration (HVAC&R) applications is thereby difficult in an already overabundant refrigerants market. In this paper, a study of key parameters required of a good refrigerant is conducted, followed by the analysis of refrigerants desired and refrigerants used in two major sectors of the HVAC&R industry, namely commercial refrigeration and residential air-conditioning and heat pumps. Finally, keeping in consideration the global environmental regulations and safety standards, a recommendation of the most suitable refrigerants in both sectors has been made.

54 ENVIRONMENTAL SCIENCES↗

A Time-Varying Model for Predicting Formaldehyde Emission Rates in Homes

Recent studies have succeeded in relating emissions of various volatile organic compounds to material mass diffusion transfer using detailed empirical characteristics of each of the individual emitting materials. While significant, the resulting models are often scenario specific and/or require a host of individual component parameters to estimate emission rates. This study developed an approach to estimate aggregated emissions rates based on a wide number of field measurements. We used a multi-parameter regression model based on previous mass transfer models to predict formaldehyde emission rate for a whole dwelling using field-measured, time-resolved formaldehyde concentrations, air exchange rates, and indoor environmental parameters in 63 California single-family houses built between 2011 and 2017. The resulting model provides time-varying formaldehyde emission rates, normalized by floor area, for each study home, assuming a well-mixed mass balance transport model of the home, and a well-mixed layer transport model of indoor surfaces. The surface layer model asserts an equilibrium concentration within the surface layer of the emitted materials that is a function of temperature and RH; the dwelling ventilation rate serves as a surrogate for indoor concentration. We also developed a more generic emission model that is suitable for broad prediction of emission for a population of buildings. This model is also based on measurements aggregated from 27 homes from the same study. We showed that errors in predicting household formaldehyde concentrations using this approach were substantially less than those using a traditional constant emission rate model, despite requiring less unique building information.

54 ENVIRONMENTAL SCIENCES↗

Hardware-Based Emulator with Deep Learning Model for Building Energy Control and Prediction Based on Occupancy Sensors’ Data

Heating, ventilation, and air conditioning (HVAC) is the largest source of residential energy consumption. Occupancy sensors’ data can be used for HVAC control since it indicates the number of people in the building. HVAC and sensors form a typical cyber-physical system (CPS). In this paper, we aim to build a hardware-based emulation platform to study the occupancy data’s features, which can be further extracted by using machine learning models. In particular, we propose two hardware-based emulators to investigate the use of wired/wireless communication interfaces for occupancy sensor-based building CPS control, and the use of deep learning to predict the building energy consumption with the sensor data. We hypothesize is that the building energy consumption may be predicted by using the occupancy data collected by the sensors, and question what type of prediction model should be used to accurately predict the energy load. Another hypothesis is that an in-lab hardware/software platform could be built to emulate the occupancy sensing process. The machine learning algorithms can then be used to analyze the energy load based on the sensing data. To test the emulator, the occupancy data from the sensors is used to predict energy consumption. The synchronization scheme between sensors and the HVAC server will be discussed. We have built two hardware/software emulation platforms to investigate the sensor/HVAC integration strategies, and used an enhanced deep learning model—which has sequence-to-sequence long short-term memory (Seq2Seq LSTM)—with an attention model to predict the building energy consumption with the preservation of the intrinsic patterns. Because the long-range temporal dependencies are captured, the Seq2Seq models may provide a higher accuracy by using LSTM architectures with encoder and decoder. Meanwhile, LSTMs can capture the temporal and spatial patterns of time series data. The attention model can highlight the most relevant input information in the energy prediction by allocating the attention weights. The communication overhead between the sensors and the HVAC control server can also be alleviated via the attention mechanism, which can automatically ignore the irrelevant information and amplify the relevant information during CNN training. Our experiments and performance analysis show that, compared with the traditional LSTM neural network, the performance of the proposed method has a 30% higher prediction accuracy.

Ye, Zhijing↗

Using Real-Time Electricity Prices to Leverage Electrical Energy Storage and Flexible Loads in a Smart Grid Environment Utilizing Machine Learning Techniques

With exposure to real-time market pricing structures, consumers would be incentivized to invest in electrical energy storage systems and smart predictive automation of their home energy systems. Smart home automation through optimizing HVAC (heating, ventilation, and air conditioning) temperature set points, along with distributed energy storage, could be utilized in the process of optimizing the operation of the electric grid. Using electricity prices as decision variables to leverage electrical energy storage and flexible loads can be a valuable tool to optimize the performance of the power grid and reduce electricity costs both on the supply and demand sides. Energy demand prediction is important for proper allocation and utilization of the available resources. Manipulating energy prices to leverage storage and flexible loads through these demand prediction models is a novel idea that needs to be studied. In this paper, different models for proactive prediction of the energy demand for an entire city using different machine learning techniques are presented and compared. The results of the machine learning techniques show that the proposed nonlinear autoregressive with exogenous inputs neural network model resulted in the most accurate predictions. These prediction models pave the way for the demand side to become an important asset for grid regulation by responding to variable price signals through battery energy storage and passive thermal energy storage using HVAC temperature set points.

25 ENERGY STORAGE↗

Wildfire Smoke Adjustment Factors for Low-Cost and Professional PM 2.5 Monitors with Optical Sensors

Air quality monitors using low-cost optical PM 2.5 sensors can track the dispersion of wildfire smoke; but quantitative hazard assessment requires a smoke-specific adjustment factor (AF). This study determined AFs for three professional-grade devices and four monitors with low-cost sensors based on measurements inside a well-ventilated lab impacted by the 2018 Camp Fire in California (USA). Using the Thermo TEOM-FDMS as reference, AFs of professional monitors were 0.85 for Grimm mini wide-range aerosol spectrometer, 0.25 for TSI DustTrak, and 0.53 for Thermo pDR1500; AFs for low-cost monitors were 0.59 for AirVisual Pro, 0.48 for PurpleAir Indoor, 0.46 for Air Quality Egg, and 0.60 for eLichens Indoor Air Quality Pro Station. We also compared public data from 53 PurpleAir PA-II monitors to 12 nearby regulatory monitoring stations impacted by Camp Fire smoke and devices near stations impacted by the Carr and Mendocino Complex Fires in California and the Pole Creek Fire in Utah. Camp Fire AFs varied by day and location, with median (interquartile) of 0.48 (0.44–0.53). Adjusted PA-II 4-h average data were generally within ±20% of PM 2.5 reported by the monitoring stations. Adjustment improved the accuracy of Air Quality Index (AQI) hazard level reporting, e.g., from 14% to 84% correct in Sacramento during the Camp Fire.

47 OTHER INSTRUMENTATION↗

An Unobstructive Sensing Method for Indoor Air Quality Optimization and Metabolic Assessment within Vehicles

This work investigates the use of an intelligent and unobstructive sensing technique for maintaining vehicle cabin’s indoor air quality while simultaneously assessing the driver metabolic rate. CO 2 accumulation patterns are of great interest because CO 2 can have negative cognitive effects at higher concentrations and also since CO 2 accumulation rate can potentially be used to determine a person’s metabolic rate. The management of the vehicle’s ventilation system was controlled by periodically alternating the air recirculation mode within the cabin, which was actuated based on the CO 2 levels inside the vehicle’s cabin. The CO 2 accumulation periods were used to assess the driver’s metabolic rate, using a model that considered the vehicle’s air exchange rate. In the process of the method optimization, it was found that the vehicle’s air exchange rate (λ [h –1 ]) depends on the vehicle speeds, following the relationship: λ = 0.060 × (speed) – 0.88 when driving faster than 17 MPH. An accuracy level of 95% was found between the new method to assess the driver’s metabolic rate (1620 ± 140 kcal/day) and the reference method of indirect calorimetry (1550 ± 150 kcal/day) for a total of N = 16 metabolic assessments at various vehicle speeds. The new sensing method represents a novel approach for unobstructive assessment of driver metabolic rate while maintaining indoor air quality within the vehicle cabin.

passive sensing↗

Performance-Based Evaluation of Courtyard Design in China’s Cold-Winter Hot-Summer Climate Regions

A courtyard is a traditional and popular construction feature found in China’s urban buildings. This case study evaluates the performance of the traditional courtyard design of the Jiangnan Museum, located in Jiangsu Province. In the evaluation, the spatial layout of courtyards is adjusted, the aspect ratio is changed, and an ecological buffer space is created. To model and evaluate the performance of the courtyard design, this study applied the Computational fluid dynamics (CFD) software, Parabolic Hyperbolic Or Elliptic Numerical Integration Code Series (PHOENICS), for wind environment simulation, and the EnergyPlus-based software, DesignBuilder, for energy simulation. Results show that a good combination of courtyard layout and aspect ratio can improve the use of natural ventilation by increasing free cooling during hot summers and reducing cold wind in winters. The results also show that ecological buffer areas of a courtyard can reduce cooling loads in summer by approximately 19.6% and heating loads in winter by approximately 22.3%. The study provides insights into the optimal design of a courtyard to maximize its benefit in regulating the microclimate during both winter and summer.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating the Adaptability of Reinforcement Learning Based HVAC Control for Residential Houses

Intelligent Heating, Ventilation, and Air Conditioning (HVAC) control using deep reinforcement learning (DRL) has recently gained a lot of attention due to its ability to optimally control the complex behavior of the HVAC system. However, more exploration is needed on understanding the adaptability challenges that the DRL agent could face during the deployment phase. Using online learning for such applications is not realistic due to the long learning period and likely poor comfort control during the learning process. Alternatively, DRL can be pre-trained using a building model prior to deployment. However, developing an accurate building model for every house and deploying a pre-trained DRL model for HVAC control would not be cost-effective. In this study, we focus on evaluating the ability of DRL-based HVAC control to provide cost savings when pre-trained on one building model and deployed on different house models with varying user comforts. We observed around 30% of cost reduction by pre-trained model over baseline when validated in a simulation environment and achieved up to 21% cost reduction when deployed in the real house. This finding provides experimental evidence that the pre-trained DRL has the potential to adapt to different house environments and comfort settings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Empirical Modeling of Direct Expansion (DX) Cooling System for Multiple Research Use Cases

This study provides a general procedure to generate a direct expansion (DX) cooling coil system for a roof top unit (RTU), which is a typical heating ventilation and air-conditioning (HVAC) system for commercial buildings in the United States. Experimental data from a full-scale unoccupied 2-story commercial building is used for the HVAC modeling. The regression for identifying the model coefficients was carried out with multiple stages, and the results were validated with measured data. The model’s applicability was evaluated with multiple case studies, including a building energy simulation (BES) program validation, model-based predictive control (MPC), and fault diagnostics and detection (FDD).

42 ENGINEERING↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Computational Fluid Dynamics Modeling to Facilitate Qualification of Stack Sampling Probe Location

Computational fluid dynamics (CFD) modeling was used to help evaluate modifications to a radiological effluent stack and assist with establishing a stack sampling location that met the mixing criteria for qualification. Requirements for stack sampling location are listed in the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-2021 standard. Modeling was performed to help develop a suitable design for increasing building ventilation for the radiological effluent stack. The ANSI/HPS N13.1-2021 criteria for the air monitoring probe location are that the coefficient of variation of velocity uniformity, gaseous tracer uniformity, and particulate tracer uniformity must be less than or equal to 20%. Furthermore, no point in the sampling location may have a gaseous tracer concentration that varies from the mean concentration by more than 30%. Additionally, the flow angle at the sampling location must not be more than 20 degrees. The ANSI/HPS N13.1-2021 standard allows for models (physical or computational) to be employed to perform the full suite of qualification tests, followed by a more limited set of verification tests on the actual stack to qualify the stack sampling location. Here, a series of computational model simulations were employed to evaluate the stack qualification criteria. Significant time and re-source savings are achieved using CFD modeling. CFD modeling demonstrated that the stack meets the criteria at the sample probe location. Verification tests were performed on the modified stack to measure the velocity uniformity and flow angle at the stack sampling location, and results demonstrated that the CFD model results may be used to support the qualification of the stack sampling location.

Air Monitoring↗

Cabin Thermal Management Analysis for SuperTruck II Next-Generation Hybrid Electric Truck Design

In this article, we present a multistage, coupled thermal management simulation approach, informed by physical testing where available, to aid design decisions for PACCAR's SuperTruck II hybrid truck cabin concept. Focus areas include cabin insulation, battery sizing, and sleeper curtain position, as well as heating, ventilating, and air-conditioning (HVAC) component and accessory configurations, to maintain or improve thermal comfort while saving energy. The authors analyzed weather data and determined the national vehicle miles traveled weighted temperature and solar conditions for long-haul trucks. Example weather day profiles were selected to approximate the 5th and 95th percentile weighted conditions. A daylong drive cycle was developed to impose appropriate external wind conditions during rest and driving periods. Using the National Renewable Energy Laboratory's vehicle HVAC modeling and simulation tool VTCab, HVAC load design trade-off studies for the new truck geometry concept were completed. Parameters analyzed included effects of paint color, insulation, glass transmissivity, and curtain location. Simulation results helped with early design material selections for efficient cabin climate control. A detailed three-dimensional computer-aided engineering (CAE), computational fluid dynamics (CFD), radiation, and human physiology co-simulation, referred to in this article as CAE Thermal-CFD, was used to evaluate thermal comfort and energy impacts of diffuser configurations and air supply settings in driving and hoteling modes. Analysis revealed that it is more difficult to heat the cabin in hoteling mode during the winter than to cool the space in the summer. This seasonal load profile drives the requirement of additional energy storage for heating comfort. To determine the battery capacity requirement, multiday HVAC operation drive cycle simulations were then completed, showing that a 15-kWh battery would be required for HVAC operation during hoteling. Results helped reduce cabin thermal loads, determine component sizing requirements, and improve occupant comfort to save fuel and contribute to the economic viability of the hybrid system.

33 ADVANCED PROPULSION SYSTEMS↗

Sleeper Cab Climate Control Load Reduction for Long-Haul Truck Rest Period Idling

Annual fuel use for long-haul truck rest period idling is estimated at 667 million gallons in the United States. The U.S. Department of Energy’s National Renewable Energy Laboratory’s CoolCab project aims to reduce heating, ventilating, and air conditioning (HVAC) loads and resulting fuel use from rest period idling by working closely with industry to design efficient long-haul truck climate control systems while maintaining occupant comfort. Enhancing the thermal performance of cab/sleepers will enable smaller, lighter, and more cost-effective idle reduction solutions. In order for candidate idle reduction technologies to be implemented at the original equipment manufacturer and fleet level, their effectiveness must be quantified. To address this need, a number of promising candidate technologies were evaluated through experimentation and modeling to determine their effectiveness in reducing rest period HVAC loads. For this study, load reduction strategies were grouped into the focus areas of solar envelope, occupant environment, and conductive pathways. The technologies selected for a complete-cab package of technologies were “ultra-white” paint, advanced insulation, and advanced curtains. To measure the impact of these technologies, a nationally-averaged solar-weighted reflectivity long-haul truck paint color was determined and applied to the baseline test vehicle. Using the complete-cab package of technologies, electrical energy consumption for long-haul truck daytime rest period air conditioning was reduced by at least 35% for summer weather conditions in Colorado. The National Renewable Energy Laboratory's CoolCalc model was then used to extrapolate the performance of the thermal load reduction technologies nationally for 161 major U.S. cities using typical weather conditions for each location over an entire year.

33 ADVANCED PROPULSION SYSTEMS↗

Climate Control Load Reduction Strategies for Electric Drive Vehicles in Warm Weather

Passenger compartment climate control is one of the largest auxiliary loads on a vehicle. Like conventional vehicles, electric vehicles (EVs) require climate control to maintain occupant comfort and safety, but cabin heating and air conditioning have a negative impact on driving range for all electric vehicles. Range reduction caused by climate control and other factors is a barrier to widespread adoption of EVs. Reducing the thermal loads on the climate control system will extend driving range, thereby reducing consumer range anxiety and increasing the market penetration of EVs. Researchers at the National Renewable Energy Laboratory have investigated strategies for vehicle climate control load reduction, with special attention toward EVs. Outdoor vehicle thermal testing was conducted on two 2012 Ford Focus Electric vehicles to evaluate thermal management strategies for warm weather, including solar load reduction and cabin pre-ventilation. An advanced thermal test manikin was used to assess a zonal approach to climate control. In addition, vehicle thermal analysis was used to support testing by exploring thermal load reduction strategies, evaluating occupant thermal comfort, and calculating EV range impacts. Through stationary cooling tests and vehicle simulations, a zonal cooling configuration demonstrated range improvement of 6%-15%, depending on the drive cycle. A combined cooling configuration that incorporated thermal load reduction and zonal cooling strategies showed up to 33% improvement in EV range.

33 ADVANCED PROPULSION SYSTEMS↗

Determining Off-Cycle Fuel Economy Benefits of 2-Layer HVAC Technology

This work presents a methodology to determine the off-cycle fuel economy benefit of a 2-Layer HVAC system which reduces ventilation and heat rejection losses of the heater core versus a vehicle using a standard system. Experimental dynamometer tests using EPA drive cycles over a broad range of ambient temperatures were conducted on a highly instrumented 2016 Lexus RX350 (3.5L, 8 speed automatic). These tests were conducted to measure differences in engine efficiency caused by changes in engine warmup due to the 2-Layer HVAC technology in use versus the technology being disabled (disabled equals fresh air-considered as the standard technology baseline). These experimental datasets were used to develop simplified response surface and lumped capacitance vehicle thermal models predictive of vehicle efficiency as a function of thermal state. These vehicle models were integrated into a database of measured on road testing and coupled with U.S. typical meteorological data to simulate vehicle efficiency across seasonal thermal and operational conditions for hundreds of thousands of drive cycles. Fuel economy benefits utilizing the 2-Layer HVAC technology are presented in addition to goodness of fit statistics of the modeling approach relative to the experimental test data.

2-layer technology↗

Assessing the National Off-Cycle Benefits of 2-Layer HVAC Technology Using Dynamometer Testing and a National Simulation Framework

Some CO2-reducing technologies have real-world benefits not captured by regulatory testing methods. This paper documents a two-layer heating, ventilation, and air-conditioning (HVAC) system that facilitates faster engine warmup through strategic increased air recirculation. The performance of this technology was assessed on a 2020 Hyundai Sonata. Empirical performance of the technology was obtained through dynamometer tests at Argonne National Laboratory. Performance of the vehicle across multiple cycles and cell ambient temperatures with the two-layer technology active and inactive indicated fuel consumption reduction in nearly all cases. A thermally sensitive powertrain model, the National Renewable Energy Laboratory's FASTSim Hot, was calibrated and validated against vehicle testing data. The developed model included the engine, cabin, and HVAC system controls. Validation of component thermal models and engine efficiency ensured accurate thermal dynamics, fuel consumption, and two-layer benefit. The real-world benefit of the two-layer technology was calculated by simulating the validated powertrain model across a representative test matrix comparing performance with and without the two-layer system. Simulation across the test matrix revealed a real-world representative benefit of 0.0835%. Analysis of test matrix results at the regional level revealed the most benefit in cold climates and rural regions. Mean results across cycle length sensitivity simulations revealed a larger real-world benefit of 0.0872%. These benefit values can be considered a more accurate assessment of real-world technology performance. Future work is planned to explore the requisite number of drive cycles to ensure the full technology benefit is captured.

2-layer↗

What do correlations tell us about anthropogenic–biogenic interactions and SOA formation in the Sacramento plume during CARES?

Abstract. During the Carbonaceous Aerosols and Radiative Effects Study (CARES) the US Department of Energy (DOE) G-1 aircraft was used to sample aerosol and gas phase compounds in the Sacramento, CA, plume and surrounding region. We present data from 66 plume transects obtained during 13 flights in which southwesterly winds transported the plume towards the foothills of the Sierra Nevada. Plume transport occurred partly over land with high isoprene emission rates. Our objective is to empirically determine whether organic aerosol (OA) can be attributed to anthropogenic or biogenic sources, and to determine whether there is a synergistic effect whereby OA concentrations are enhanced by the simultaneous presence of high concentrations of carbon monoxide (CO) and either isoprene, MVK + MACR (sum of methyl vinyl ketone and methacrolein), or methanol, which are taken as tracers of anthropogenic and biogenic emissions, respectively. Linear and bilinear correlations between OA, CO, and each of three biogenic tracers, “Bio”, for individual plume transects indicate that most of the variance in OA over short timescales and distance scales can be explained by CO. For each transect and species a plume perturbation, (i.e., ΔOA, defined as the difference between 90th and 10th percentiles) was defined and regressions done amongst Δ values in order to probe day-to-day and location-dependent variability. Species that predicted the largest fraction of the variance in ΔOA were ΔO 3 and ΔCO. Background OA was highly correlated with background methanol and poorly correlated with other tracers. Because background OA was ~60 % of peak OA in the urban plume, peak OA should be primarily biogenic and therefore non-fossil, even though the day-to-day and spatial variability of plume OA is best described by an anthropogenic tracer, CO. Transects were split into subsets according to the percentile rankings of ΔCO and ΔBio, similar to an approach used by Setyan et al. (2012) and Shilling et al. (2013) to determine if anthropogenic–biogenic (A–B) interactions enhance OA production. As found earlier, ΔOA in the data subset having high ΔCO and high ΔBio was several-fold greater than in other subsets. Part of this difference is consistent with a synergistic interaction between anthropogenic and biogenic precursors and part to an independent linear dependence of ΔOA on precursors. The highest values of ΔO 3 , along with high temperatures, clear skies, and poor ventilation, also occurred in the high ΔCO–high ΔBio data set. A complicated mix of A–B interactions can result. After taking into account linear effects as predicted from low concentration data, an A–B enhancement of OA by a factor of 1.2 to 1.5 is estimated.

54 ENVIRONMENTAL SCIENCES↗

The diurnal cycle of the smoky marine boundary layer observed during August in the remote southeast Atlantic

Ascension Island (8° S, 14.5° W) is located at the northwestern edge of the south Atlantic stratocumulus deck, with most clouds in August characterized by surface observers as “stratocumulus and cumulus with bases at different levels”, and secondarily as “cumulus of limited vertical extent” and occurring within a typically decoupled boundary layer. Field measurements have previously shown that the highest amounts of sunlight-absorbing smoke occur annually within the marine boundary layer during August. On more smoke-free days, the diurnal cycle in cloudiness includes a nighttime maximum in cloud liquid water path and rain, an afternoon cloud minimum, and a secondary late-afternoon increase in cumulus and rain. The afternoon low-cloud minimum is more pronounced on days with a smokier boundary layer. The cloud liquid water paths are also reduced throughout most of the diurnal cycle when more smoke is present, with the difference from cleaner conditions most pronounced at night. Precipitation is infrequent. An exception is the mid-morning, when the boundary layer deepens and liquid water paths increase. The data support a view that a radiatively enhanced decoupling persisting throughout the night is key to understanding the changes in the cloud diurnal cycle when the boundary layer is smokier. Under these conditions, the nighttime stratiform cloud layer does not always recouple to the sub-cloud layer, and the decoupling maintains more moisture within the sub-cloud layer. After the sun rises, enhanced shortwave absorption in a smokier boundary layer can drive a vertical ascent that momentarily couples the sub-cloud layer to the cloud layer, deepening the boundary layer and ventilating moisture throughout, a process that may also be aided by a shift to smaller droplets. After noon, shortwave absorption within smokier boundary layers again reduces the upper-level stratiform cloud and the sub-cloud relative humidity, discouraging further cumulus development and again strengthening a decoupling that lasts longer into the night. The novel diurnal mechanism provides a new challenge for cloud models to emulate. The lower free troposphere above cloud is more likely to be cooler, when boundary layer smoke is present, and lower free-tropospheric winds are stronger and more northeasterly, with both (meteorological) influences supporting further smoke entrainment into the boundary layer from above.

54 ENVIRONMENTAL SCIENCES↗