Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Unit Testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

MST Filterability Tests

The Savannah River Site (SRS) is currently treating radioactive liquid waste with the Actinide Removal Process (ARP) and the Modular Caustic Side Solvent Extraction Unit (MCU). The low filter flux through the ARP has limited the rate at which radioactive liquid waste can be treated. Recent filter flux has averaged approximately 5 gallons per minute (gpm). Salt Batch 6 has had a lower processing rate and required frequent filter cleaning. Savannah River Remediation (SRR) has a desire to understand the causes of the low filter flux and to increase ARP/MCU throughput. In addition, at the time the testing started, SRR was assessing the impact of replacing the 0.1 micron filter with a 0.5 micron filter. This report describes testing of MST filterability to investigate the impact of filter pore size and MST particle size on filter flux and testing of filter enhancers to attempt to increase filter flux. The authors constructed a laboratory-scale crossflow filter apparatus with two crossflow filters operating in parallel. One filter was a 0.1 micron Mott sintered SS filter and the other was a 0.5 micron Mott sintered SS filter. The authors also constructed a dead-end filtration apparatus to conduct screening tests with potential filter aids and body feeds, referred to as filter enhancers. The original baseline for ARP was 5.6 M sodium salt solution with a free hydroxide concentration of approximately 1.7 M.3 ARP has been operating with a sodium concentration of approximately 6.4 M and a free hydroxide concentration of approximately 2.5 M. SRNL conducted tests varying the concentration of sodium and free hydroxide to determine whether those changes had a significant effect on filter flux. The feed slurries for the MST filterability tests were composed of simple salts (NaOH, NaNO 2 , and NaNO 3 ) and MST (0.2 – 4.8 g/L). The feed slurry for the filter enhancer tests contained simulated salt batch 6 supernate, MST, and filter enhancers.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Batch contact testing with variable Na AN-107 and AP-105

The Hanford Site stores an estimated 56 million gallons of mixed radioactive and chemically hazardous waste in large underground tanks. In support of the Direct Feed Low-Activity Waste (DFLAW) program for expediting Hanford tank waste supernate treatment, laboratory-scale ion exchange processing using prototypic unit operations was conducted on AW-105 tank waste at the Pacific Northwest National Laboratory Radiochemical Processing Laboratory. This report describes the batch contact testing for tanks AN-107 and AP-105 to help evaluate CST performance on tanks waste supernate after processing it in the ion exchange columns. Batch columns were performed with the wastes at six Na concentrations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accident tolerant fuel test 2c (ATF-2C) irradiation test report

A fully prototypic testing platform for testing new accident tolerant fuel (ATF) designs for light water reactors has been established in the center flux trap of Idaho National Laboratory’s advanced test reactor (ATR). The irradiation experiment named ATF-2C has completed its four cycles of prototypic steady state irradiation. Irradiation conditions have been maintained via the loop 2a pressurized water coolant loop and have been monitored through in-situ instrumentation during each cycle. Power and burnup histories of each of the 18 fueled test pins has been calculated.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Establishing Models for Digital Twin of Hydropower Systems Using Probability Density Function Shaping

This paper introduces a digital twin modeling method for hydropower systems with Kaplan turbines using probability density function (PDF) shaping. We first use multilayer perceptron (MLP) model to build the discretized openloop Kaplan unit, where the MLP is trained by historical data. Then we use a proportional integral double derivative (PIDD) controller and a lead-lag exciter to test the obtained digital twin model in a closed-loop fashion. Simulation results show that the proposed digital twin modeling method can accurately capture the dynamics of the Kaplan hydropower unit. Finally, we show that the obtained digital twin can help to optimize the PIDD parameters. Compared with the original PIDD controller, the optimized one can achieve an over 90% improvement on the mean square tracking error.

Yin, Zhun [New York University]↗

Hydrologic Evaluation of the Ringold Upper Mud Aquifer in the 100-H Area of the Hanford Site

Aquifer tests were recently performed in the Hanford Site 100-H Area to provide a hydrologic evaluation of the Ringold Formation member of Wooded Island – upper mud unit (RUM) aquifer to reduce uncertainty regarding its lateral continuity and characterize aquifer properties within the high-concentration portion of the RUM Cr(VI) plume. A constant-rate pumping test was performed in well 199-H3-22 in October 2019. Additionally, the hydraulic responses from pump and treat (P&T) shutdown events occurring in June, July, and October 2019 were analyzed for aquifer hydraulic properties.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Understanding the Quadrupole Mass Filter and Testing a High-Resolution QMS RGA for ITER

A common type of residual gas analyzer is the quadrupole mass spectrometer. One of the main components within this instrument is a mass filter known as the quadrupole. It is responsible for the selective throughput of the ionized gas particles - by ascending mass number - prior to ion impacts on the analyzer (or detector) surface from which the ion current signal is generated for processing. However, the quadrupole is not fully described in relation to the electric field characteristics and the function as an ion mass separator. This paper describes the basic origins of the electrical design, the intricate assembly criteria, and performance of the quadrupole within the spectrometer. A specialized quadrupole mass spectrometer is part of a configuration for a diagnostic gas analyzer system planned for ITER, a fusion research machine. It has a verified capability, essential as a diagnostic criterion for this reactor project, to successfully deconvolute the mass signals of Helium-4 and deuterium (reactor fuel exhaust gases, separated by only 0.026 atomic mass units), down to a relative three-percent concentration of the former gas. The associated preliminary testing, performed at the Oak Ridge National Laboratory, is also addressed. Finally, one of the key parameters used to express gas concentration, the relative sensitivity factor, will be explained, including an evaluation of dependency on other variables.

Marcus, Chris [ORNL] (ORCID:0000000190139636)↗

Detailed Evaluation of Electric Demand Load Shifting Potential of Heat Pump Water Heaters

Future utilities will emphasize home appliances to reduce greenhouse gas emissions while providing electric load shifting and demand profile management. Heat pump water heaters (HPWH) have demonstrated the ability to cut water heating energy by more than 65% compared with conventional electric resistance waters (ERWH). Laboratory research was conducted on the load shifting potential of grid-connected heat pump water heaters (HPWH), compared to ERWHs. Testing applied different CTA-2045 command designs. Highly-controlled laboratory experiments were conducted on one ERWH and four HPWHs, including a prototype incorporating the new CTA-2045-B protocol feature allowing ‘advanced’ load up above the tank setpoint. The prototype unit with the B-protocol increased tank temperature by 15oF (8.3C) under the advanced load up providing an increase of 1.8 kWh of storage for a 50-gallon (189 liter) tank. The prototype includes a built-in mixing valve to meet anti-scalding codes. With the load-shaping ability of CTA-2045-B, utilities might be able to store excess renewable energy in connected tanks when renewable wind and solar resource production is high. Tests were performed under baseline conditions (no load shift) and under several load-shifting schemes, including load up and advanced load up, ahead of shed commands. Grid-connected HPWHs reduced peak demand by as much as 0.5 kW, depending on tank volume, time of day, control scheme, and draw profile.

heat pump water heater, Demand flexibility, load s↗

Exterior Insulation Systems Containing Vacuum Insulation Panels Tested Using a Heat Flux Meter Apparatus

A proposed wall system that will provide a high thermal resistance in a relatively thin profile incorporates vacuum insulation panels (VIP) enclosed within closed-cell insulating foam. In addition to providing some additional thermal resistance, the foam protects the vacuum panels during construction and provides a surface appropriate for an adhesive joint on both sides of the foam-VIP unit. Multiple configurations of the composite structure were considered and experimental measurements were sought to provide more information in the final selection. Small sub-sections of each candidate arrangement were prepared and tested in a special-purpose heat flux meter apparatus. Those measurements are described here, along with additional modeling efforts based on these smaller-scale measurements. The focus of the tests reported here is to investigate the impact of vacuum panel size, the type of foam used to encase the vacuum panels, the thickness and shape of the foam sections between panels, and possible adhesive effects. A new procedure was developed to map the heat flux meter measurement results onto full-scale wall designs to predict the system thermal performance. Several potential arrangements of the foam-VIP unit were also evaluated using a finite-difference methodology. The report also evaluates procedures for testing VIPs in a heat flux meter apparatus, and makes some recommendations.

Childs, Kenneth W.↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Detecting inhomogeneities in the Twentieth Century Reanalysis over the central United States

The Twentieth Century Reanalysis (20CR), which spans the 138 year period from 1871 to 2008, was intended for a variety of climate applications, including long–term trend assessment. Because over land 20CR only assimilates surface pressure observations and their count increases by an order of magnitude over the course of the record, a key question is whether the 20CR is homogenous and hence suitable for detecting climate–related changes. We use three statistical methods (Pettitt and Bai–Perron tests and segmented regression) to detect abrupt shifts in multiple hydrometeorological variable mean and uncertainty fields over the central United States. For surface air temperature and precipitation, we use the Climate Research Unit (CRU) time series data set for comparison. We find that for warm–season months, there is a consensus change point among all variables between 1940 and 1950, which is not substantiated by the CRU record. While we cannot say with certainty that these shifts in the 20CR analysis fields are artificial, our statistical analyses, coupled with a visual inspection of the underlying assimilated observational count time series, strongly point to this conclusion. Furthermore, our recommendation is therefore for users to restrict climate trend applications over the central United States to the second half century of the 20CR record, after observational density has stabilized.

54 ENVIRONMENTAL SCIENCES↗

Asynchronous GPU-based DEM solver embedded in commercial CFD software with polyhedral mesh support

A novel graphical processing unit-based discrete element method solver is introduced to improve stability, performance, and provide seamless integration into commercial or open-source computational fluid dynamics software. A key innovation is eliminating a need for network communication between solvers, which was previously required for cross-platform coupling. This is accomplished by a direct coupling method that employs dynamic-linked libraries. Furthermore, the solver optimizes memory usage by streamlining the particle-cell search algorithm by eliminating the cells' searching grid. This ensures the solver is compatible with a wide range of mesh types, providing high geometric flexibility. The approach simplifies the simulation process by directly incorporating computational fluid dynamics mesh information into the discrete element method solver. The performance analysis indicates about sixteen times boost in computational speed compared to benchmark central processing unit-based solvers. Finally, the solver's compatibility with polyhedral meshes, a vital advantage for complex geometries, is tested against a referenced study regarding the simulation of an immersed-tube fluidized bed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Charge Reduction and Performance Analysis of a Heat Pump Water Heater Using R290 as a Refrigerant—A Field Study

Heat pump water heaters (HPWHs) are a proven technology for water heating that has been commercialized. The adoption of HPWHs for domestic and commercial water heating is growing rapidly because of their superior performance compared with alternative water heating methods. Whereas most existing systems use R-134a as a working refrigerant, R290 has gained major attention owing to its superior thermodynamic properties. The goal of the current study is to assess the performance of residential HPWH with R290 as a direct refrigerant replacement for R134a. Two units of a 50 gal HPWH were used in this experimental study. A baseline unit contained R134a refrigerant, and a prototype unit contained R290 refrigerant. The prototype unit was developed through the modification of a commercially available HPWH unit to achieve a low charge of R290 refrigerant. Another major modification was the replacement of the baseline compressor with a compressor designed for R290. Tests were conducted in a field environment (a research and demonstration house) using programmed drawn profiles daily. The prototype that reduced the charge by 43–47% provided displayed performance comparable to the baseline unit regarding first-hour rating (FHR) and the uniform energy factor (UEF).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Low-E Retrofit Demonstration and Educational Program

The objective of this project was to demonstrate the capability of low-emissivity (low-E) storm windows / panels and low-E retrofit glazing systems to significantly and cost effectively improve the energy efficiency of both existing residential and commercial buildings. The key outcomes are listed below: RESIDENTIAL CASE STUDIES: (a) A residential case study in two large multifamily apartment buildings in Philadelphia showed a substantial 18-22% reduction in heating energy use and a 9% reduction in cooling energy use by replacing old clear glass storm windows with modern low-E storm windows. Furthermore, the new low-E storm windows reduced the overall apartment air leakage by an average of 10%. (b) Air leakage testing on interior low-E panels installed in a New York City multifamily building over windows with and without AC units showed that the effective leakage area of the windows was reduced by 77-95%. (c) To study the use of low-E storm windows in a warmer mixed climate with a balance of both heating and cooling, 10 older homes near Atlanta with single pane windows were tested with three types of exterior storm windows: clear glass, low-E glass with high solar heat gain, and low-E glass with lower solar heat gain. The storm windows significantly reduced the overall home air leakage by an average of 17%, or 3.7 ACH50. Considerably high variability in the data made it difficult to draw strong conclusions about the overall energy usage, but for heating periods, the low-E storm windows showed approximately 15% heating energy savings, whereas clear storm windows were neutral in performance. For cooling periods, the low-E storm windows showed a wide range of performance from 2% to over 30% cooling energy savings. Overall, the study showed the potential for significantly more energy savings from using low-E glass versus no storm window or clear glass storm windows in warmer mixed climates, but it is difficult to conclusively say whether one type of low-E performed better than the other. COMMERCIAL CASE STUDIES: (a) A 12-story office building in Philadelphia was retrofitted by adding a double-pane low-E insulating glass unit to the existing single pane windows, to create a triple glazed low-E system. A detailed side-by-side comparison in two pairs of perimeter offices facing north and east showed a 39-60% reduction in heating energy use, a 9-36% reduction in cooling energy use, and a 10% reduction in peak electrical cooling demand. An analysis of utility bills estimated the whole building heating and cooling energy use was reduced by over 25%. Additionally, the retrofit window temperatures were commonly 20 degrees warmer on winter days, and 10-20 degrees cooler on summer days, leading to increased occupant comfort. (b) Two large 4-story office buildings in New Jersey were retrofitted with a similar system, but using two low-E coatings in the retrofit system. The energy savings are being monitored by a separate GPIC project; this work quantified the changes in glass surface temperatures, thermal comfort, and potential glass thermal stress. The low-E retrofit panels greatly reduced daily variations in the interior window surface temperatures, lowering the maximum temperature and raising the minimum temperature by over 20F compared to the original single pane windows with window film. The number of hours of potential thermal discomfort, as measured by deviation between mean radiant temperature and ambient air temperature by more than 3F, were reduced by 93 percent on the south orientation and over two-thirds on the west orientation. Overall, the low-E retrofit led to substantially improved occupant comfort with less periods of both overheating and feeling cold. (c) No significant thermal stress was observed in the New Jersey office building test window when using the low-E retrofit system over a variety of weather conditions. The surface temperature difference only exceeded 10F (500 psi thermal stress) for less than 1.5% of the monitored time, and in all cases, the maximum surface temperature difference never exceeded 35F (1,750 psi thermal stress). LOW-E STORM WINDOW OUTREACH AND EDUCATION PROGRAM: (a) The project team assisted the State of Pennsylvania in adding low-E storm windows as a cost effective weatherization measure on its priority list for the state weatherization assistance program. (b) No technical barriers that could hinder widespread application were identified in the case studies. However, educational barriers have been identified, in that weatherization personnel commonly misunderstand how the application of low-E storm windows is very different than much more expensive full window replacement. (c) A package of educational materials was developed to help communicate the benefits of low-E storm windows and retrofits as a cost effective tool for weatherization personnel. (d) Using detailed thermal simulations, more accurate U-factor and solar heat gain coefficient (SHGC) values were determined for low-E storm windows installed over different primary windows. IN SUMMARY, this work confirmed the potential for low-E storm windows, panels, and retrofit systems to provide significant energy savings, reductions in air leakage, and improvements in thermal comfort in both residential and commercial existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Improvement of Drop‐Hammer Impact Testing for Safety Assessment of High Explosives Using 10‐mg Samples

Here, in this study, we established an improved method for drop-hammer impact testing of small quantities of high explosives (10 mg). We performed about seven hundred impact tests under various experimental conditions (e.g., sandpaper vs bare anvil, different sample masses, drop-weights, and striker diameters) to determine an optimal set of conditions and reaction detection methods (e.g., gas analysis, video, and sound recordings) that give the most statistically reliable results with 10 mg samples. We used both Frequentist and Bayesian statistical approaches to compare estimates of the drop height (DH50) that initiates a reaction 50% of the time, and to quantify the associated uncertainty. Gas analysis proved to be the most reliable reaction detection method, showing unambiguous rises in HE decomposition products (e.g., CO 2 ) even when the other indicators (e.g., sound, video) were inconclusive. The impact tests performed with a bare anvil showed much better reproducibility than those conducted with sandpaper, reducing the largest uncertainty observed in the data sets by a factor of 1.7. The DH 50 values obtained from three different sample masses (10, 20, and 35 mg) fell within the uncertainties of the measurements. We demonstrated the improved procedure (i.e., 10-mg samples, gas analysis, bare anvil, and Bayesian approach) on a variety of PETN samples having different surface areas and thermal histories.

PETN↗

Test of Weak Equivalence Principle with the Multi-band Timing of the Crab Pulsar

The Weak Equivalent Principle (WEP) can be tested through the parameterized post-Newtonian parameter γ, representing the space curvature produced by unit rest mass. The parameter γ in turn has been constrained by comparing the arrival times of photons originating in distant transient events, such as gamma-ray bursts, fast radio bursts, and giant pulses of pulsars. Those measurements normally correspond to an individual burst event with very limited energy bands and signal-to-noise ratios (S/Ns). In this paper, the discrepancy in the pulse arrival times of the Crab Pulsar between different energy bands is obtained by the phase difference between corresponding pulse profiles. This allows us to compare the pulse arrival times at the largest energy band differences, between radio and optical, radio and X-ray, and radio and gamma-ray respectively. Because the pulse profiles are generated by phase-folding thousands of individual pulses, the time discrepancies between two energy bands are actually measured from thousands of events at each energy band, which corresponds to a much higher S/N. The upper limit of the γ discrepancy set by such an extensively observed and well-modeled source is as follows: γ{sub radio}--γ{sub γ-ray}<3.28×10{sup −9} at the energy difference of E{sub γ-ray}/E{sub radio}∼10{sup 13}, γ{sub radio}--γ{sub X-ray}<4.01×10{sup −9} at the energy difference of E{sub X-ray}/E{sub radio}∼10{sup 9}, γ{sub radio}--γ{sub optical}<2.63×10{sup −9} at E{sub optical}/E{sub radio}∼10{sup 5}, and γ{sub optical}--γ{sub γ-ray}<3.03×10{sup −10} at E{sub γ-ray}/E{sub optical}∼10{sup 8}. This actually measures the arrival times of freely falling photons in the gravitational field of the Milky Way with the largest amount of events and with data of the highest S/N, which tests WEP at energy band differences that have never been reached before.

79 ASTRONOMY AND ASTROPHYSICS↗

Sorption (K d ) Measurements in Support of Dose Assessments for Zion Nuclear Station Decommissioning

The Zion Nuclear Power Station is being decommissioned. ZionSolutions proposes to leave much of the below grade structures in place and to fill them with “clean” concrete demolition debris from the above grade parts of the facility. This study, commissioned by ZionSolutions and conducted by the Brookhaven National Laboratory (BNL) was performed to provide site-specific data for performance assessment calculations to support the request to terminate the NRC license and allow unrestricted use of the facility. Specifically, this study measured the distribution coefficient for five radionuclides of concern using site-specific soils and groundwater. The distributions coefficient is a measure of the amount of the radionuclide that will remain sorbed to the soil or concrete that is present relative to the amount that will remain in solution. A high distribution coefficient indicates most of the radionuclide will remain on the solid material and will not be available for transport by the groundwater. The radionuclides of concern are Fe-55, Co-60, Ni-63, Sr-90, and Cs-137. Tests were performed following ASTM C1733-10, Standard Test Methods for Distribution Coefficients of Inorganic Species by the Batch Method. Sr-85 was used in the testing as an analogue for Sr-90 because it behaves similarly with respect to sorption and has a gamma emission that is easier to detect than the beta emission from Sr-90. Site-specific soils included disturbed sand (sand removed during construction and used as backfill), native sand, silt/clay and silt. In addition, concrete cores from the Unit-1 Containment Building and the Crib House were broken into particles less than 2 mm in size and tested to obtain distribution coefficients for the five nuclides.

54 ENVIRONMENTAL SCIENCES↗

An assessment of total depletion uncertainties for a GBC-32 dry storage cask with PLUS7 fuels using Monte Carlo sampling and two-way ANOVA F-test

It is important to accurately evaluate depletion uncertainties that exist due to the limitations of a computer code on accuracy in a nuclear depletion calculation for criticality safety analysis. In this work, the bias and bias uncertainty in the effective neutron multiplication factor (k{sub eff}) for the generic 32 PWR-assembly burnup credit (GBC-32) cask system were assessed using the Monte Carlo uncertainty sampling method for three different burnups and the isotopic biases and uncertainties obtained with the calculated and measured isotopic concentrations. The PLUS7 used nuclear fuel assemblies discharged from the Hanbit Nuclear Power Plant Unit 3 were assumed to be loaded into the GBC-32 cask. In addition, the statistical F-test in the two-way analysis of variance (ANOVA) was suggested to efficiently estimate the statistically converged total depletion uncertainty in k{sub eff}, with a significant reduction of computing efforts in the Monte Carlo criticality calculations, and it was applied to the GBC-32 cask system after a sensitivity analysis was performed to select the important nuclides having significant contributions to the total depletion uncertainty. With the statistical F-tests in the two-way ANOVA, 100 criticality calculations were needed to get a statistically converged total depletion uncertainty for 10 and 30 GWD/MTU, while 120 criticality calculations were needed for 50 GWD/MTU. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Effect of Monomer Structure on Crystallization and Glass Transition of Flexible Copolyesters

Amorphous flexible (co)polyesters with low glass transition temperature (T{sub g}) are very desirable in impact modification of biodegradable brittle polymers and synthesis of biodegradable elastomers. However, most flexible polyesters and binary copolyesters made from linear diacid(s) and diol(s) are crystalline polymers. In order to investigate the effect of monomer structure on the crystallization and T{sub g} of such copolyesters, novel ternary or multiple flexible copolyesters containing various structural units were designed and synthesized in this study, and characterized with {sup 1}HNMR, GPC, DSC, WAXD, TGA and tensile testing. Introducing aromatic diacid (especially asymmetric one) or short-chain branched diol is favorable to depress copolyester crystallization, and leads to higher T{sub g} at the same time. From easily crystallized to fully amorphous copolyesters with low T{sub g} were successfully synthesized by adopting different combination of structural units. In addition, the existence of aromatic structural unit in copolyesters is helpful to improve their tensile properties. Graphical Abstract: Flexible copolyesters containing various structural units were designed and synthesized. Introducing asymmetric, rigid aromatic or short-chain branched unit is favorable to depress copolyester crystallization, and leads to higher T{sub g} at the same time. Crystalline to fully amorphous copolyesters with low enough T{sub g} have been successfully synthesized by adjusting the structural units. .

36 MATERIALS SCIENCE↗