Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “UNDERGROUND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Status of the OPERA experiment

The OPERA experiment in the underground Gran Sasso Laboratory (LNGS) has been designed to perform the first detection of neutrino oscillations in direct appearance mode in the muon to tau neutrino channel. The detector is hybrid, being made of an emulsion/lead target and of electronic detectors. It is placed in the CNGS neutrino beam 733 km away from the neutrino source. Runs with CNGS neutrinos were successfully carried out from 2008 and the following years. The analysis of a sample of events corresponding to 1.89x10{sup 19} p.o.t. in the CERN CNGS {nu}{sub {mu}} beam yielded the observation of a first candidate {nu}{sub {tau}} CC interaction. The topology and kinematics of this candidate event is described in detail. The background sources are explained and the significance of the observation of the first {nu}{sub {tau}} event candidate is assessed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of {nu}-bar{sub e}-e scattering cross section with CsI(Tl) detector array and the Beyond Standard Model constraints

A search of {nu}-bar{sub e}-e scattering cross section was carried out at the Kuo-Sheng nuclear power station. Based on 29882 and 7369 kg-days of reactor ON/OFF data, respectively, at an average reactor ON {nu}-bar{sub e} flux of 6.4x10{sup 12} cm{sup -2} s{sup -1}, the standard model (SM) electroweak interaction was probed at the squared 4-momentum transfer range of Q{sup 2}{approx}3x10{sup -6} GeV{sup 2}. The ratio of experimental to SM cross section was measured [1.08{+-}0.21(stat){+-}0.16(sys)]. We placed the constraints on the electroweak parameters (g{sub V},g{sub A}), corresponding to a weak mixing angle measurement of sin{sup 2}{theta}{sub W} = 0.251{+-}0.031(stat){+-}0.024(sys). A Point Contact Germanium Detector (PCGe) of mass 1 kg has been installed at a new underground laboratory 'China Jin-Ping Laboratory (CJPL)' in China.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Cryogenic Bolometer for 0{nu}{beta}{beta} in {sup 124}Sn

Cryogenic bolometer detectors, with their high resolution spectroscopy capability, are ideal for neutrino mass experiments as well as for search of rare processes like neutrinoless double beta decay (0{nu}{beta}{beta}) and dark matter. A feasibility study for investigation of 0{nu}{beta}{beta} in {sup 124}Sn at the upcoming underground facility of India based Neutrino Observatory (INO) has been initiated. This paper describes endeavors towards cryogenic tin bolometer development.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First fusion proton measurements in TEXTOR plasmas using activation technique

MeV particle loss measurements from fusion plasmas, in particular alpha particles, remain difficult in large fusion devices and further R and D is needed for ITER. This paper describes the first attempt to measure 3 MeV escaping fusion protons emitted from TEXTOR tokamak plasmas using activation technique. This technique was successfully demonstrated, initially, in 2006 on the JET tokamak. An ion camera equipped with a collimator and several types of activation detectors was installed inside the TEXTOR vacuum vessel to perform these measurements. After irradiation, the detectors were analyzed using ultra low level gamma-ray spectrometry at the HADES underground laboratory. 3 MeV escaping fusion protons were detected in larger number -{approx}6 times more - compared to earlier measurements using this technique on JET. Another major progress was the reduction of the cooling time by a factor of 50, which made possible to detect radionuclides with half-life of less than 90 min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low background counting at the LBNL low background facility

The Low Background Facility (LBF) at the Lawrence Berkeley National Laboratory (LBNL) in Berkeley, California provides low background gamma spectroscopy services to end-users in two unique facilities: locally within a carefully-constructed, low background laboratory space; and a satellite underground station (600 m.w.e) in Oroville, CA. These facilities provide a variety of gamma spectroscopy services to low background experiments primarily in the form of passive material screening for primordial radioisotopes (U, Th, K) or common cosmogenic and anthropogenic products, as well as active screening via neutron activation analysis for specific applications. A general overview of the facilities, services, and capabilities will be discussed. Recent activities will also be presented, including the recent installation of a 3π muon veto at the surface facility, cosmogenic activation studies of TeO{sub 2} for CUORE, and environmental monitoring of Fukushima fallout.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

GERDA phase II detectors: Behind the production and characterisation at low background conditions

The low background GERmanium Detector Array (GERDA) at Laboratori Nazionali del Gran Sasso (LNGS) is designed to search for the rare neutrinoless double beta decay (0νββ) in {sup 76}Ge. Bare germanium diodes are operated in liquid argon which is used as coolant, as passive and soon active as well shield against external radiation. Currently, Phase I of the experiment is running using ∼15 kg of co-axial High Purity Germanium diodes. In order to increase the sensitivity of the experiment 30 Broad Energy Germanium (BEGe) diodes will be added within 2013. This presentation reviews the production chain of the new BEGe detectors from isotopic enrichment to diode production and testing. As demonstrated all steps were carefully planned in order to minimize the exposure of the enriched germanium to cosmic radiation. Following this premise, acceptance and characterisation measurement of the newly produced diodes have been performed within the HEROICA project in the Belgian underground laboratory HADES close to the diode manufacturer. The test program and the results from a subset of the recently terminated GERDA Phase II BEGe survey will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of low radioactivity background in a high voltage cable by high resolution inductively coupled plasma mass spectrometry

The measurement of naturally occurring low level radioactivity background in a high voltage (HV) cable by high resolution inductively coupled plasma mass spectrometry (HR ICP MS) is presented in this work. The measurements were performed at the Chemistry Service of the Gran Sasso National Laboratory. The contributions to the radioactive background coming from the different components of the heterogeneous material were separated. Based on the mass fraction of the cable, the whole contamination was calculated. The HR ICP MS results were cross-checked by gamma ray spectroscopy analysis that was performed at the low background facility STELLA (Sub Terranean Low Level Assay) of the LNGS underground lab using HPGe detectors.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pixel detectors in double beta decay experiments, a new approach for background reduction

Double beta decay (ββ) experiments are challenging frontiers in contemporary physics. These experiments have the potential to investigate more about neutrinos (eg. nature and mass). The main challenge for these experiments is the reduction of background. The group at IEAP, CTU in Prague is investigating a new approach using pixel detectors Timepix. Pixel detector offer background reduction capabilities with its ability to identify the particle interaction (from the 2D signature it generates). However, use of pixel detectors has some challenges such as the presence of readout electronics near the sensing medium and heat dissipation. Different aspects of pixel setup (identification of radio-impurities, selection of radio-pure materials) and proposed experimental setup are presented. Also, results of preliminary background measurements (performed on the surface and in the underground laboratories) using the prototype setups are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

BiPo: A dedicated radiopurity detector for the SuperNEMO experiment

New generation experiments in Astroparticle Physics need to operate in really restrictive background conditions, which implies the use of high radiopure materials for the experimental setup construction. For this reason the screening of the materials with enough sensitivity has become a challenge that sometimes cannot be afforded with standard techniques like Germanium detector spectroscopy. BiPo is a dedicated detector, that operates in the Canfranc Underground Laboratory, designed to measure the radiopurity, mainly of the ββ sources of the SuperNEMO experiment, by the detection of BiPo events. It is composed of two modules with 40 optical lines each one, registering the energy and the time of the emitted particles. The well known features of the BiPo events (delayed coincidence between an electron and an alpha particle) facilitate the discrimination of other background events that could entangle the expected signal. In addition, the geometry of the detector, with an active area of around 3.6 m{sup 2}, has been optimized to reach the necessary sensitivity levels for the SuperNEMO source foils in the shortest time possible. Preliminary results of background measurements and calibrations taken since summer 2012 shows that the required sensitivity for the measurements of the source foils could be reached in few months. Routine measurements of samples are already started being an important point for the SuperNEMO source foils construction.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

High sensitivity detectors for measurement of diffusion, emanation and low activity of radon

Today's underground experiments require ultra-low background conditions. One of the most important source of background is radon. It is necessary to suppress it and consequently to detect very low radon concentration. In the frame of SuperNEMO collaboration experimental setups for measurement of low radon activity, radon diffusion through shielding foils and radon emanation from construction materials have been constructed in IEAP CTU in Prague and the obtained results are presented. The application of Timepix device in radon detection is briefly discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Purification of lanthanides for double beta decay experiments

There are several potentially double beta active isotopes among the lanthanide elements. However, even high purity grade lanthanide compounds contain {sup 238}U, {sup 226}Ra and {sup 232,228}Th typically on the level of ∼ (0.1 - 1) Bq/kg. The liquid-liquid extraction technique was used to remove traces of U, Ra and Th from CeO{sub 2}, Nd{sub 2}O{sub 3} and Gd{sub 2}O{sub 3}. The radioactive contamination of the samples before and after the purification was tested by using ultra-low-background HPGe γ spectrometry at the underground Gran Sasso National Laboratories of the INFN (Italy). After the purification the radioactive contamination of gadolinium oxide by Ra and Th was decreased at least one order of magnitude. The efficiency of the approach to purify cerium oxide from Ra was on same level, while the radioactive contamination of neodymium sample before and after the purification is below the sensitivity of analytical methods. The purification method is much less efficient for chemically very similar radioactive elements like lanthanum, lutetium and actinium. R and D of the methods to remove the pollutions with improved efficiency is in progress.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Acoustic studies for alpha background rejection in dark matter bubble chamber detectors

COUPP (Chicagoland Observatory for Underground Particle Physics) is an experiment with bubble chambers able to detect dark matter directly either with Spin-Dependent or with Spin-Independent interactions. The target material is a superheated liquid (usually CF3I) that can be bubble nucleated due to nuclear recoils produced by elastic collisions of dark matter particles. The bubble growth inside the chamber is accompanied with an acoustic signature. The acoustic technique has been successfully used to have a good alpha discrimination (about 99%). In this paper, we present different studies and results related with the characterization of the acoustic properties of the detector and the different phenomena involved in the acoustic measurements of the bubble growth, such as sound generation, sound transmission and optimization of piezoelectric transducers.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background studies for NaI(Tl) detectors in the ANAIS dark matter project

Several large NaI(Tl) detectors, produced by different companies, have been operated in the Canfranc Underground Laboratory (LSC) in the frame of the ANAIS (Annual modulation with NaI Scintillators) project devoted to the direct detection of dark matter. A complete background model has been developed for a 9.6 kg detector (referred as ANAIS-0 prototype) after a long data taking at LSC. Activities from the natural chains of {sup 238}U and {sup 232}Th, and {sup 40}K in the NaI(Tl) crystal were evaluated applying different methods: discrimination of alpha particles vs beta/gamma background by Pulse Shape Analysis for quantifying the content of the natural chains and coincidence techniques for {sup 40}K. Radioactive contaminations in the detector and shielding components were also determined by HPGe spectrometry. Monte Carlo simulations using Geant4 package were carried out to evaluate their contribution. At high energies, most of the measured background is nicely reproduced; at low energy some non-explained components are still present, although some plausible background sources have been analyzed. The {sup 40}K content of the NaI(Tl) crystal has been confirmed to be the dominant contributor to the measured background with this detector. In addition, preliminary results of the background characterization, presently underway at the LSC, of two recently produced NaI(Tl) detectors, with 12.5 kg mass each, will be presented: cosmogenic induced activity has been clearly observed and is being quantified, and {sup 40}K activity at a level ten times lower than in ANAIS-0 has been determined.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HEROICA: A fast screening facility for the characterization of germanium detectors

In the course of 2012, a facility for the fast screening of germanium detectors called HEROICA (Hades Experimental Research Of Intrinsic Crystal Appliances) has been installed at the HADES underground laboratory in the premises of the Belgian Nuclear Research Centre SCK•CEN, in Mol (Belgium). The facility allows performing a complete characterization of the critical germanium detectors' operational parameters with a rate of about two detectors per week.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Water purification in Borexino

Astroparticle Physics and Underground experiments searching for rare nuclear events, need high purity materials to act as detectors or detector shielding. Water has the advantage of being cheap, dense and easily available. Most of all, water can be purified to the goal of obatining a high level of radiopurity. Water Purification can be achieved by means of a combination of processes, including filtration, reverse osmosis, deionization and gas stripping. The Water Purification System for the Borexino experiment, will be described together with its main performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background considerations for SuperCDMS

Rejection and protection from background is a key issue for the next generation SuperCDMS SNOLAB experiment that will have a cross-section sensitivity of better than 8 × 10{sup −46} cm{sup 2} for spin-independent WIMP-nucleon interactions. This paper presents the details of the methods used to reject electromagnetic backgrounds using the new iZIP detectors that are currently operated in the Soudan Underground Laboratory, MN and the methods the collaboration is investigating to protect against neutron background in the next generation SuperCDMS experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling surface backgrounds from radon progeny plate-out

The next generation low-background detectors operating deep underground aim for unprecedented low levels of radioactive backgrounds. The surface deposition and subsequent implantation of radon progeny in detector materials will be a source of energetic background events. We investigate Monte Carlo and model-based simulations to understand the surface implantation profile of radon progeny. Depending on the material and region of interest of a rare event search, these partial energy depositions can be problematic. Motivated by the use of Ge crystals for the detection of neutrinoless double-beta decay, we wish to understand the detector response of surface backgrounds from radon progeny. We look at the simulation of surface decays using a validated implantation distribution based on nuclear recoils and a realistic surface texture. Results of the simulations and measured α spectra are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Exploring the {sup 22}Ne(p,γ){sup 23}Na reaction at LUNA and at HZDR

The {sup 22}Ne(p,γ){sup 23}Na reaction is involved in the hydrogen burning NeNa cycle. This determines the nucleosynthesis of the Ne and Na isotopes in the Red Giant Branch and Asymptotic Giant Branch phases of stellar evolution. In the energy range relevant for astrophysics (20 keV < E < 600 keV), the {sup 22}Ne(p,γ){sup 23}Na reaction rate is highly uncertain because of the contribution of a large number of resonances never measured directly. A related study is under preparation at the Laboratory for Underground Nuclear Astrophysics (LUNA), in the Gran Sasso National Laboratory, and it will cover the energy range 100 keV < E < 400 keV. Meanwhile, a measurement at higher energies (i.e. 436 keV) has been carried out at the Tandetron accelerator of the HZDR (Helmholtz Zentrum Dresden Rossendorf) in Germany. Some preliminary results will be presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗