Galaxy clustering, photometric redshifts and diagnosis of systematics in the DES Science Verification data
Abstract Not Provided
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract Not Provided
Cross sections and analyzing powers for polarized proton elastic scattering from {sup 58}Ni, and {sup 204,206,208}Pb were measured at intermediate energy E{sub p}=295 MeV. An effective relativistic Love-Franey interaction is tuned to reproduce {sup 58}Ni scattering data within the framework of the relativistic impulse approximation. The neutron densities of the lead isotopes are deduced using model-independent sum-of-Gaussians distributions. Their error envelopes are estimated by a new {chi}{sup 2} criterion including uncertainties associated with the reaction model. The systematic behaviors of extracted error envelopes of the neutron density distributions in {sup 204,206,208}Pb are presented. The extracted neutron and proton density distribution of {sup 208}Pb gives a neutron skin thickness of {Delta}r{sub np}=0.211{sub -0.063}{sup +0.054} fm.
Purpose: Image-guided radiation therapy (IGRT) is one of the major treatment of esophageal cancer. Gray value registration and bone registration are two kinds of image registration, the purpose of this work is to compare which one is more suitable for esophageal cancer patients. Methods: Twenty three esophageal patients were treated by Elekta Synergy, CBCT images were acquired and automatically registered to planning kilovoltage CT scans according to gray value or bone registration. The setup errors were measured in the X, Y and Z axis, respectively. Two kinds of setup errors were analysed by matching T test statistical method. Results: Four hundred and five groups of CBCT images were available and the systematic and random setup errors (cm) in X, Y, Z directions were 0.35, 0.63, 0.29 and 0.31, 0.53, 0.21 with gray value registration, while 0.37, 0.64, 0.26 and 0.32, 0.55, 0.20 with bone registration, respectively. Compared with bone registration and gray value registration, the setup errors in X and Z axis have significant differences. In Y axis, both measurement comparison results of T value is 0.256 (P value > 0.05); In X axis, the T value is 5.287(P value < 0.05); In Z axis, the T value is −5.138 (P value < 0.05). Conclusion: Gray value registration is recommended in image-guided radiotherapy for esophageal cancer and the other thoracic tumors. Manual registration could be applied when it is necessary. Bone registration is more suitable for the head tumor and pelvic tumor department where composed of redundant interconnected and immobile bone tissue.
Thermal expansion data for more than 5500 compositions of silicate glasses were analyzed statistically. These data were gathered from the scientific literature, summarized in SciGlass© 6.5, a new version of the well known glass property database and information system. The analysis resulted in a data reduction from 5500 glasses to a core of 900, where the majority of the published values is located within commercial glass composition ranges and obtained over the temperature range 20 to 500°C. A multiple regression model for the linear thermal expansivity at 210°C, including error formula and detailed application limits, was developed based on those 900 core data from over 100 publications. The accuracy of the model predictions is improved about twice compared to previous work because systematic errors from certain laboratories were investigated and corrected. The standard model error (precision) was 0.37 ppm/K, with R² = 0.985. The 95% confidence interval for individual predictions largely depends on the glass composition of interest and the composition uncertainty. The model is valid for commercial silicate glasses containing Na2O, CaO, Al2O3, K2O, MgO, B2O3, Li2O, BaO, ZrO2, TiO2, ZnO, PbO, SrO, Fe2O3, CeO2, fining agents, and coloring and de-coloring components. In addition, a special model for ultra-low expansion glasses in the system SiO2-TiO2 is presented. The calculations allow optimizing the time-temperature cooling schedule of glassware, the development of glass sealing materials, and the design of specialty glass products that are exposed to varying temperatures.
Abstract. Wind lidars are widespread and important tools in atmospheric observations. An intrinsic part of lidar measurement error is due to atmospheric variability in the remote-sensing scan volume. This study describes and quantifies the distribution of measurement error due to turbulence in varying atmospheric stability. While the lidar error model is general, we demonstrate the approach using large ensembles of virtual WindCube V2 lidar performing a profiling Doppler-beam-swinging scan in quasi-stationary large-eddy simulations (LESs) of convective and stable boundary layers. Error trends vary with the stability regime, time averaging of results, and observation height. A systematic analysis of the observation error explains dominant mechanisms and supports the findings of the empirical results. Treating the error under a random variable framework allows for informed predictions about the effect of different configurations or conditions on lidar performance. Convective conditions are most prone to large errors (up to 1.5 m s−1 in 1 Hz wind speed in strong convection), driven by the large vertical velocity variances in convective conditions and the high elevation angle of the scanning beams (62∘). Range-gate weighting induces a negative bias into the horizontal wind speeds near the surface shear layer (−0.2 m s−1 in the stable test case). Errors in the horizontal wind speed and direction computed from the wind components are sensitive to the background wind speed but have negligible dependence on the relative orientation of the instrument. Especially during low winds and in the presence of large errors in the horizontal velocity estimates, the reported wind speed is subject to a systematic positive bias (up to 0.4 m s−1 in 1 Hz measurements in strong convection). Vector time-averaged measurements can improve the behavior of the error distributions (reducing the 10 min wind speed error standard deviation to <0.3 m s−1 and the bias to <0.1 m s−1 in strong convection) with a predictable effectiveness related to the number of decorrelated samples in the time window. Hybrid schemes weighting the 10 min scalar- and vector-averaged lidar measurements are shown to be effective at reducing the wind speed biases compared to cup measurements in most of the simulated conditions, with time averages longer than 10 min recommended for best use in some unstable conditions. The approach in decomposing the error mechanisms with the help of the LES flow field could be extended to more complex measurement scenarios and scans.
Modern digital instrumentation and control (I and C) systems offer nearly unlimited functional capability. However, the complexity of their design (including their system software and application software) is significantly higher than that of conventional, hardwired systems, to the point that it is generally impossible to demonstrate that there are no residual design errors, even when the best development and verification techniques have been applied. When activated by specific conditions, design errors could result in systematic failures, i.e., failures that occur deterministically each time and wherever an activating condition is present. Redundancy could be defeated when the same design error affects multiple channels or systems, and the activating condition affects several of these channels or systems. In the case of safety I and C systems, most of the functions are poised protection functions that must be actuated when and only when a demand situation occurs in the plant. In nuclear power plants, the most dangerous failure mode for such functions generally is failure to actuate, and many measures are taken to protect from such failure mode. This paper considers the other failure modes of safety I and C functions, and also the failure modes of the other I and C functions that are less important to safety. It is not limited to poised functions, and considers other types of functions such as regulation functions or human interface functions. It proposes a framework for analyzing and providing defense against spurious actuations and other incorrect behaviors from digital I and C systems directly interacting with the plant process or with operators: these might be useful for example to justify that design bases for reactor protection are adequate, or to ensure plant performance and availability. (authors)
Purpose: A fully automated, fast, on-line prostate repositioning scheme using implanted markers, kilovoltage/megavoltage imaging, and remote couch movements has been developed and clinically applied. The initial clinical results of this stereographic targeting (SGT) method, as well as phantom evaluations, are presented. Methods and Materials: Using the SGT method, portal megavoltage images are acquired with the first two to six monitor units of a treatment beam, immediately followed by acquisition of an orthogonal kilovoltage image without gantry motion. The image pair is automatically analyzed to obtain the marker positions and three-dimensional prostate displacement and rotation. Remote control couch shifts are applied to correct for the displacement. The SGT performance was measured using both phantom images and images from 10 prostate cancer patients treated using SGT. Results: With phantom measurements, the accuracy of SGT was 0.5, 0.2, and 0.3 mm (standard deviation [SD]) for the left-right, craniocaudal, and anteroposterior directions, respectively, for translations and 0.5{sup o} (SD) for the rotations around all axes. Clinically, the success rate for automatic marker detection was 99.5%, and the accuracy was 0.3, 0.5 and 0.8 mm (SD) in the left-right, craniocaudal, and anteroposterior axes. The SDs of the systematic center-of-mass positioning errors ({sigma}) were reduced from 4.0 mm to <0.5 mm for all axes. The corresponding SD of the random ({sigma}) errors was reduced from 3.0 to <0.8 mm. These small residual errors were achieved with a treatment time extension of <1 min. Conclusion: Stereographic targeting yields systematic and random prostate positioning errors of <1 mm with <1 min of added treatment time.
To follow up on the unexpectedly good performance of several coupled-cluster models with approximate inclusion of 3-body clusters we performed a more complete assessment of the 3CC method for accurate computational thermochemistry in the standard HEAT framework. New spin-integrated implementation of the 3CC method applicable to closed- and open-shell systems utilizes a new automated toolchain for derivation, optimization, and evaluation of operator algebra in many-body electronic structure. We found that with a double-ζ basis set the 3CC correlation energies and their atomization energy contributions are almost always more accurate (with respect to the CCSDTQ reference) than the CCSDT model as well as the standard CCSD(T) model. The mean absolute errors in cc-pVDZ {3CC, CCSDT, and CCSD(T)} electronic (per valence electron) and atomization energies relative to the CCSDTQ reference for the HEAT data set, were {24, 70, 122} μE h /e and {0.46, 2.00, 2.58} kJ/mol, respectively. The mean absolute errors in the complete-basis-set limit {3CC, CCSDT, and CCSD(T)} atomization energies relative to the HEAT model reference, were {0.52, 2.00, and 1.07} kJ/mol, The significant and systematic reduction of the error by the 3CC method and its lower cost than CCSDT suggests it as a viable candidate for post- CCSD(T) thermochemistry applications, as well as the preferred alternative to CCSDT in general.
We propose a systematic approach that can empirically correct three major errors typically found in a density functional theory (DFT) calculation within the local density approximation (LDA) simultaneously for a set of common cation binary semiconductors, such as III-V compounds, (Ga or In)X with X = N,P,As,Sb, and II-VI compounds, (Zn or Cd)X, with X = O,S,Se,Te. By correcting (1) the binary band gaps at high-symmetry points , L, X, (2) the separation of p-and d-orbital-derived valence bands, and (3) conduction band effective masses to experimental values and doing so simultaneously for common cation binaries, the resulting DFT-LDA-based quasi-first-principles method can be used to predict the electronic structure of complex materials involving multiple binaries with comparable accuracy but much less computational cost than a GW level theory. This approach provides an efficient way to evaluate the electronic structures and other material properties of complex systems, much needed for material discovery and design.
Purpose: To determine whether setup margins can be reduced using cone-beam computed tomography (CBCT) to localize tumor in conventionally fractionated radiotherapy for lung tumors. Methods and Materials: A total of 22 lung cancer patients were treated with curative intent with conventionally fractionated radiotherapy using daily image guidance with CBCT. Of these, 13 lung cancer patients had sufficient CBCT scans for analysis (389 CBCT scans). The patients underwent treatment simulation in the BodyFix immobilization system using four-dimensional CT to account for respiratory motion. Daily alignment was first done according to skin tattoos, followed by CBCT. All 389 CBCT scans were retrospectively registered to the planning CT scans using automated soft-tissue and bony registration; the resulting couch shifts in three dimensions were recorded. Results: The daily alignment to skin tattoos with no image guidance resulted in systematic ({sigma}) and random ({sigma}) errors of 3.2-5.6 mm and 2.0-3.5 mm, respectively. The margin required to account for the setup error introduced by aligning to skin tattoos with no image guidance was approximately 1-1.6 cm. The difference in the couch shifts obtained from the bone and soft-tissue registration resulted in systematic ({sigma}) and random ({sigma}) errors of 1.5-4.1 mm and 1.8-5.3 mm, respectively. The margin required to account for the setup error introduced using bony anatomy as a surrogate for the target, instead of localizing the target itself, was 0.5-1.4 cm. Conclusion: Using daily CBCT soft-tissue registration to localize the tumor in conventionally fractionated radiotherapy reduced the required setup margin by up to approximately 1.5 cm compared with both no image guidance and image guidance using bony anatomy as a surrogate for the target.
Accurate day-ahead load forecasting is essential for reliable power system operations and market efficiency. System operators such as the Midcontinent Independent System Operator (MISO) rely on forecasts from multiple vendors, yet combining them effectively remains a persistent challenge due to vendor-specific biases. This paper presents a novel LSTM-Attention Fusion Network with Error Representation (LAF-Net) that enhances day-ahead hourly load forecasting through deep residual learning and multi-modal cross-attention. The proposed model builds a historical error memory from past vendor performance and dynamically queries it with future hour context to generate adaptive, hour-specific trust weights for each vendor. A bounded residual correction further refines forecasts by mitigating systematic and temporally localized errors. Tested on real MISO LBA data with multi-vendor forecasts, LAF-Net consistently outperforms the best vendor baseline across all 38 LBAs, achieving more than a 40% reduction in system-level mean absolute error (MAE) during peak load hours relative to the best vendor baseline.
The computational resources needed to generate the ab initio solution of the nuclear many-body problem for increasing mass number and/or accuracy necessitates innovative developments to improve upon (i) the storage of many-body operators and (ii) the scaling of many-body methods used to evaluate nuclear observables. The storing and efficient handling of many-body operators with high particle ranks is currently one of the major bottlenecks limiting the applicability range of ab initio studies with respect to mass number and accuracy. Recently, the application of tensor decomposition techniques to many-body tensors has proven highly beneficial to reduce the computational cost of ab initio calculations in quantum chemistry and solid-state physics. The impact of applying state-of-the-art tensor factorization techniques to modern nuclear Hamiltonians derived from chiral effective field theory is investigated. Subsequently, the error induced by the tensor decomposition of the input Hamiltonian on ground-state energies of closed-shell nuclei calculated via second-order many-body perturbation theory is benchmarked. The first proof-of-principles application of tensor-decomposition techniques to the nuclear Hamiltonian is performed. Two different tensor formats are investigated by systematically benchmarking the approximation error on matrix elements stored in various bases of interest. The analysis is achieved while including normal-ordered three-nucleon interactions that are nowadays used as input to the most advanced ab initio calculations in medium-mass nuclei. With the aid of the factorized Hamiltonian, the second-order perturbative correction to ground-state energies is decomposed and the scaling properties of the underlying tensor network are discussed. The employed tensor formats are found to lead to an efficient data compression of two-body matrix elements of the nuclear Hamiltonian. In particular, the sophisticated tensor hypercontraction scheme yields low tensor ranks with respect to both harmonic-oscillator and Hartree-Fock single-particle bases. It is found that the tensor rank depends on the two-body total angular momentum J for which one performs the decomposition, which is itself directly related to the sparsity of the corresponding tensor. Furthermore, including normal-ordered two-body contributions originating from three-body interactions does not compromise the efficient data compression. Ultimately, the use of factorized matrix elements authorizes controlled approximations of the exact second-order ground-state energy corrections. In particular, a small enough error is obtained from low-rank factorizations in He4,O16, and Ca40. It is presently demonstrated that tensor-decomposition techniques can be efficiently applied to systematically approximate the nuclear many-body Hamiltonian in terms of lower-rank tensors. Beyond the input Hamiltonian, tensor-decomposition techniques can be envisioned to scale down the cost of state-of-the-art nonperturbative many-body methods in order to extend ab initio studies to (i) higher precisions, (ii) larger masses, and (iii) nuclei of doubly open-shell character.
Using a 478 pb⁻¹ data sample collected with the BESIII detector operating at the Beijing Electron Positron Collider storage ring at a center-of-mass energy of s√=4.009 GeV, the production of e⁺e⁻→ηJ/ψ is observed for the first time with a statistical significance of greater than 10σ. The Born cross section is measured to be (32.1±2.8±1.3) pb, where the first error is statistical and the second systematic. Assuming the ηJ/ψ signal is from a hadronic transition of the ψ(4040), the fractional transition rate is determined to be B(ψ(4040)→ηJ/ψ)=(5.2±0.5±0.2±0.5)×10⁻³, where the first, second, and third errors are statistical, systematic, and the uncertainty from the ψ(4040) resonant parameters, respectively. The production of e⁺e⁻→π0J/ψ is searched for, but no significant signal is observed, and B(ψ(4040)→π⁰J/ψ)<2.8×10⁻⁴ is obtained at the 90% confidence level.
Patients with cervical, uterine, and rectal carcinomas are usually treated in the prone position using the bellyboard positioning device. Specific and uncomfortable prone position gives rise to uncertainties in the daily set-up of patients during the treatment. During investigation of translational movements, rotational movements of the pelvis are observed and investigated. The film portal imaging is used to discover patient positioning errors during treatment. We defined the rotational set-up errors by angle deviations of the sacrum. Thirty-six patients were included in the study; 15 patients were followed during the whole treatment and 21 during the first 5 consecutive treatment days. The image acquisitions were completed in 84%. Systematic and random positioning errors were analyzed in 725 images. Approximately half of the patients had adjusted to the bellyboard in the first few fractions, with sacrum angles remaining the same for the rest of the treatment. The other half had drifts of the sacrum angle during the whole treatment. The rotation of the sacrum during treatment ranged up to 14 deg., causing the usual set-up verification and correction procedure to result in errors up to 15 mm. Rotational movements of the patient pelvis during bellyboard pelvis radiotherapy can introduce considerable patient position error.
Purpose: This study presents an adaptive error detection algorithm (AEDA) for real-timein vivo point dosimetry during high dose rate (HDR) or pulsed dose rate (PDR) brachytherapy (BT) where the error identification, in contrast to existing approaches, does not depend on an a priori reconstruction of the dosimeter position. Instead, the treatment is judged based on dose rate comparisons between measurements and calculations of the most viable dosimeter position provided by the AEDA in a data driven approach. As a result, the AEDA compensates for false error cases related to systematic effects of the dosimeter position reconstruction. Given its nearly exclusive dependence on stable dosimeter positioning, the AEDA allows for a substantially simplified and time efficient real-time in vivo BT dosimetry implementation. Methods: In the event of a measured potential treatment error, the AEDA proposes the most viable dosimeter position out of alternatives to the original reconstruction by means of a data driven matching procedure between dose rate distributions. If measured dose rates do not differ significantly from the most viable alternative, the initial error indication may be attributed to a mispositioned or misreconstructed dosimeter (false error). However, if the error declaration persists, no viable dosimeter position can be found to explain the error, hence the discrepancy is more likely to originate from a misplaced or misreconstructed source applicator or from erroneously connected source guide tubes (true error). Results: The AEDA applied on twoin vivo dosimetry implementations for pulsed dose rate BT demonstrated that the AEDA correctly described effects responsible for initial error indications. The AEDA was able to correctly identify the major part of all permutations of simulated guide tube swap errors and simulated shifts of individual needles from the original reconstruction. Unidentified errors corresponded to scenarios where the dosimeter position was sufficiently symmetric with respect to error and no-error source position constellations. The AEDA was able to correctly identify all false errors represented by mispositioned dosimeters contrary to an error detection algorithm relying on the original reconstruction. Conclusions: The study demonstrates that the AEDA error identification during HDR/PDR BT relies on a stable dosimeter position rather than on an accurate dosimeter reconstruction, and the AEDA’s capacity to distinguish between true and false error scenarios. The study further shows that the AEDA can offer guidance in decision making in the event of potential errors detected with real-timein vivo point dosimetry.
The authors report a study of B{sup {+-}} {yields} D*K{sup {+-}} decays with D* decaying to D{pi}{sup 0} or D{gamma}, using 383 x 10{sup 6} B{bar B} pairs collected at the {Upsilon}(4S) resonance with the BABAR detector at the SLAC PEP-II B-Factory. The D meson decays under study include a non-CP mode (K{sup {+-}}{pi}{sup {-+}}), CP-even modes (K{sup {+-}}K{sup {-+}}, {pi}{sup {+-}}{pi}{sup {-+}}) and CP-odd modes (K{sub S}{sup 0}{pi}{sup 0}, K{sub S}{sup 0}{phi}, K{sub S}{sup 0}{omega}). They measure ratios (R*{sub CP{+-}}) of branching fractions of decays to CP eigenmode states and to flavor-specific states as well as CP asymmetries A*{sub CP{+-}} = -0.11 {+-} 0.09 {+-} 0.01, R*{sub CP+} = 1.31 {+-} 0.13 {+-} 0.04, and A*{sub CP-} = 0.06 {+-} 0.10 {+-} 0.02, R*{sub CP-} = 1.10 {+-} 0.12 {+-} 0.04, where the first error is statistical and the second error is systematic. Translating the results into an alternative parameterization, widely used for related measurements, they obtain x*{sub +} = 0.11 {+-} 0.06 {+-} 0.02 and x*{sub -} = 0.00 {+-} 0.06 {+-} 0.01. No significant CP-violating charge asymmetry is found in either the flavor-specific mode D {yields} K{sup {+-}}{pi}{sup {-+}} or in B{sup {+-}} {yields} D*{pi}{sup {+-}} decays.
Abstract Spurred by recent advances in detector technology and X-ray optics, upgrades to scanning-probe-based tomographic imaging have led to an exponential growth in the amount and complexity of experimental data and have created a clear opportunity for tomographic imaging to approach single-atom sensitivity. The improved spatial resolution, however, is highly susceptible to systematic and random experimental errors, such as center of rotation drifts, which may lead to imaging artifacts and prevent reliable data extraction. Here, we present a model-based approach that simultaneously optimizes the reconstructed specimen and sinogram alignment as a single optimization problem for tomographic reconstruction with center of rotation error correction. Our algorithm utilizes an adaptive regularizer that is dynamically adjusted at each alternating iteration step. Furthermore, we describe its implementation in a software package targeting high-throughput workflows for execution on distributed-memory clusters. We demonstrate the performance of our solver on large-scale synthetic problems and show that it is robust to a wide range of noise and experimental drifts with near-ideal throughput.
We present a lattice QCD calculation of the Δ I = 1 / 2 , K → π π decay amplitude A 0 and ϵ ' , the measure of direct C P violation in K → π π decay, improving our 2015 calculation [1] of these quantities. Both calculations were performed with physical kinematics on a 32 3 × 64 lattice with an inverse lattice spacing of a - 1 = 1.3784 ( 68 ) GeV . However, the current calculation includes nearly 4 times the statistics and numerous technical improvements allowing us to more reliably isolate the π π ground state and more accurately relate the lattice operators to those defined in the standard model. We find Re ( A 0 ) = 2.99 ( 0.32 ) ( 0.59 ) × 10 - 7 GeV and Im ( A 0 ) = - 6.98 ( 0.62 ) ( 1.44 ) × 10 - 11 GeV , where the errors are statistical and systematic, respectively. The former agrees well with the experimental result Re ( A 0 ) = 3.3201 ( 18 ) × 10 - 7 GeV . These results for A 0 can be combined with our earlier lattice calculation of A 2 [2] to obtain Re ( ϵ ' / ϵ ) = 21.7 ( 2.6 ) ( 6.2 ) ( 5.0 ) × 10 - 4 , where the third error represents omitted isospin breaking effects, and Re ( A 0 ) / Re ( A 2 ) = 19.9 ( 2.3 ) ( 4.4 ) . The first agrees well with the experimental result of Re ( ϵ ' / ϵ ) = 16.6 ( 2.3 ) × 10 - 4 . A comparison of the second with the observed ratio Re ( A 0 ) / Re ( A 2 ) = 22.45 ( 6 ) , demonstrates the standard model origin of this “ Δ I = 1 / 2 rule” enhancement.