Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Synchronization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Implementation of a 1550-nm laser system for beam characterization at the Argonne Wakefield Accelerator

Accurately recording an electron bunch’s longitudinal profile is an important diagnostic for wakefield accelerators employing shaped bunches to increase transformer ratios. Electro-optic sampling of terahertz radiation from the bunch is an attractive approach due to its non-destructive nature. In preparation for future characterization experiments, the Argonne Wakefield Accelerator test facility has recently installed a 1550 nm laser system, including the necessary support systems to synchronize with the photoinjector laser system at 81.25 MHz. We report here on the initial installation and synchronization demonstrations.

Ody, Alexander [Argonne, PHY]↗

SPS High Bandwidth Transverse Feedback System MD (1/23/2012)

We continue to have problems remaining synchronized with the beam. At this point we are not sure what the cause is. Typical problems associated with the timing shift: loss of synchronization of back end timing with the bunch by as much at a fraction of a nanosecond to several nanoseconds. Sometimes the front end timing changes and sometimes not. We eventually were able to synchronize quickly, by simply looking at the kicker load signal. JC has begun to recognize waveform traces typical of proper synchronization. For these initial tests, this should be good enough. Used a 200 MHz non amplitude modulated signal, measured the sum of the 200 MHz signal out of excitation and feedback systems, file Jan-22-932. Typically, out of the H9, 320 mV pp corresponds to both system begin aligned, with set attenuation. We were able to take many measurements where we scanned the phase of the FIR filter and varied the gain to determine the phase that damps the beam motion. $\phi$ ~ 90°. Performed some drive and damp measurements, driving mode 0, see Table 2 for details. Had a chromaticity sweep implemented and monitored the bunch with feedback on and off, see Table 3 for details.

ACCPHY↗

Assessment of the Electrical Substation-Grid Testbed with Inside/Outside Devices and Distributed Ledger Technology

The electrical substation-grid testbed was created to integrate the GOOSE and/or DNP (Distributed Network Protocol) messages with time synchronized sources and Distributed Ledger Technology (DLT). The objective was to study the impact of faults and cyber-events at an electrical substation with inside (protective relays) and outside (power meters) substation devices. The electrical substation-grid testbed was based on the design of a 34.5/ 12.47 kV electrical substation (sectionalized bus configuration) with two power transformers, connected to radial power lines and load feeders. The electrical substation-grid testbed was installed at 252 lab space (Advanced Power System Protection), Grid Research Integration and Deployment Center (GRID-C), Oak Ridge National Laboratory. This testbed was created for Task 5, DarkNet project. The electrical substation-grid testbed was created to simulate fault and/or cyber events that could potentially result in damage to the electrical infrastructure. In addition, tests were run that are usually not allowed to be performed in an operational electrical power grid, because these test scenarios could trip breakers and/or generate fault situations that could potentially damage equipment. The number of tests performed in the electrical substation-grid testbed were executed in a better way than in a real electrical substation and/or power grid, because multiple tests could be run in a short period of time, and complex permits, and safety/ schedule restrictions like in a real electrical substation environment were not needed. The electrical substation-grid testbed was created using real measurement, communication, and protection devices that are used by electrical utilities, to have same conditions that we could observe in a real power grid or electrical substation. The electrical substation-grid testbed was based on using a real time simulator and expansion box with amplifiers that were wired to electrical substation-grid devices. This hardware-in-the-loop (HIL) was provided by protective relays, power meters, ethernet switches, remote terminal units, synchronized timing network clock, DLT devices, workstations, and servers. This report includes the design, installation, and assessment of the electrical substation-grid testbed that was similar to an operational electrical substation, integrating the power system protection, communication, and control systems. The results for the electrical substation-grid testbed were based on:• verifying the analog signals for protective relays and power meters, • observing the synchronized time source frame at devices, • authenticating the GOOSE (IEC 61850) and DNP messages from power meters and protective relays, and • verifying the trip conditions of protective relays at fault tests with the power system fault event detection, using DLT devices. For future work, the electrical substation-grid testbed with protective relays and power meters, using DLT and synchronized time source from DarkNet, will be used to study the impact of cyber-events at inside and outside substation devices. Advanced algorithms for detecting cyber-events produced by non-desired protective relay settings will be studied, to improve the detection and reliability of protection, control, and communication systems at power grids.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Study of the Impact of Reduced Inertia in Power Systems

Inertia in power systems plays an important role in maintaining the stability and reliability of the system by counteracting changes in frequency. However, the traditional sources of synchronous generation are being displaced by renewable resources, which often have no inherent inertia. This paper investigates the impact of reduced system inertia on several aspects of the dynamic stability of power systems, such as angular stability, primary frequency response, and oscillatory modes. This study is performed on a large-scale 2000 bus synthetic Texas model by selectively replacing synchronous generators with inverter-based generation resources. This paper also compares the analysis results obtained by the above-mentioned inertia-reduction approach of renewable integration with another approach in which the inertia constant of all synchronous generators is decreased. This paper demonstrates that only reducing the inertia of all synchronous generators in a system does not provide an accurate analysis of the challenges associated with the reduced system inertia caused by renewable integration.

System Inertia, Angular stability, System Inertial↗

Optimization of Asynchronous Communication Operations through Eager Notifications

UPC++ is a C++ library implementing the Asynchronous Partitioned Global Address Space (APGAS) model. We propose an enhancement to the completion mechanisms of UPC++ used to synchronize communication operations that is designed to reduce overhead for on-node operations. Our enhancement permits eager delivery of completion notification in cases where the data transfer semantics of an operation happen to complete synchronously, for example due to the use of shared-memory bypass. This semantic relaxation allows removing significant overhead from the critical path of the implementation in such cases. We evaluate our results on three different representative systems using a combination of microbenchmarks and five variations of the the HPCChallenge RandomAccess benchmark implemented in UPC++ and run on a single node to accentuate the impact of locality. We find that in RMA versions of the benchmark written in a straightforward manner (without manually optimizing for locality), the new eager notification mode can provide up to a 25% speedup when synchronizing with promises and up to a 13.5x speedup when synchronizing with conjoined futures. We also evaluate our results using a graph matching application written with UPC++ RMA communication, where we measure overall speedups of as much as 11% in single-node runs of the unmodified application code, due to our transparent enhancements.

Kamil, Amir↗

Parallel operation of two Brayton-cycle alternators with parasitic speed controllers

The experimental paralleling characteristics of two 1200 Hz Brayton-cycle alternators are presented. Since the Brayton power conversion system uses electric speed controllers, the paralleling requirements are somewhat different from those for conventional ground-based systems. Results include the transient effects of synchronizing the two alternators with various phase-angle, voltage, and frequency differences. Based on these results, the effects of synchronizing differences can be defined, and adjustment requirements of the parasitic speed controllers during synchronizing can be established. Data indicate that parasitically loaded alternators are able to parallel over a wide range of synchronizing differences. However, equilibrium could not be reached in extreme cases where alternator load differences were great and, at the same time, the phase-angle error was large (150 deg or more).

Perz, D. A.↗

Parallel operation of two Brayton-cycle alternators with parasitic speed controllers.

The experimental paralleling characteristics of two 1200-Hz Brayton-cycle alternators are presented. Since the Brayton power conversion system uses electric speed controllers, the paralleling requirements are somewhat different from those for conventional ground-based power systems. Results include the transient effects of synchronizing the two alternators with various phase-angle, voltage, and frequency differences. Based on these results, the effects of synchronizing differences can be defined, and adjustment requirements of the parasitic speed controllers during synchronizing can be established. Data indicate that parasitically loaded alternators are able to parallel over a wide range of synchronizing differences.

Perz, D. A.↗

Precision time distribution within a deep space communications complex

The Precision Time Distribution System (PTDS) at the Golstone Deep Space Communications Complex is a practical application of existing technology to the solution of a local problem. The problem was to synchronize four station timing systems to a master source with a relative accuracy consistently and significantly better than 10 microseconds. The solution involved combining a precision timing source, an automatic error detection assembly and a microwave distribution network into an operational system. Upon activation of the completed PTDS two years ago, synchronization accuracy at Goldstone (two station relative) was improved by an order of magnitude. It is felt that the validation of the PTDS mechanization is now completed. Other facilities which have site dispersion and synchronization accuracy requirements similar to Goldstone may find the PTDS mechanization useful in solving their problem. At present, the two station relative synchronization accuracy at Goldstone is better than one microsecond.

Curtright, J. B.↗

Motor run-up system

A starting system is described for bringing a large synchronous motor up to speed to prevent large power line disturbances at the moment the motor is connected to the power line. The system includes (1) a digital counter which generates a count determined by the difference in frequency between the power line and a small current generated by the synchronous motor; (2) a latch which stores the count; and (3) a comparator which compares the stored count with a newly generated count to determine whether the synchronous motor is accelerating or decelerating. Signals generated by the counter and comparator control the current to a clutch that couples a starting motor to the large synchronous motor.

Daeges, J. J.↗

Comparison between variable and fixed dwell-time PN acquisition algorithms

Pseudo noise (PN) spread spectrum systems require a very accurate alignment between the PN code epochs at the transmitter and receiver. This synchronism is typically established through a two-step algorithm, including a coarse synchronization procedure and a fine synchronization procedure. A standard approach for the coarse synchronization is a sequential search over all code phases. The measurement of the power in the filtered signal is used to either accept or reject the code phase under test as the phase of the received PN code. This acquisition strategy, called a single dwell-time system, has been analyzed by Holmes and Chen (1977). A synopsis of the field of sequential analysis as it applies to the PN acquisition problem is provided. From this, the implementation of the variable dwell time algorithm as a sequential probability ratio test is developed. The performance of this algorithm is compared to the optimum detection algorithm and to the fixed dwell-time system.

Braun, W. R.↗

Ensuring fault tolerance of phase-locked clocks

Processors within a real-time multiprocessor system must be synchronized with as little overhead as possible. Although synchronization can be achieved via both software (e.g., interactive convergence and interactive consistency algorithms) and hardware (e.g., multistage synchronizers and phase-locked clocks), phase-locked clocks are most attractive due to their small overheads. Despite the fact that synchronization of the multiprocessor system with phase-locked clocks is totally different in nature from the interactive consistency algorithm, it is presently proven that it must satisfy the same condition, N equal to or greater than 3m + 1, where N is the total number of clocks in the multiprocessor system and m is the maximum number of faults tolerable. Also presented are results showing how to design phase-locked clocks so as to be impervious up to a given arbitrary number of malicious failures.

Krishna, C. M.↗

Fairness of channel access for non-time-critical traffic using the FDDI token ring protocol

The Fiber Distributed Data Interface (FDDI) is an ANSI draft proposed standard for a 100 megabit per second fiber optic token ring. FDDI supports two types of traffic, synchronous and asynchronous. Synchronous traffic is time critical traffic; stations are assigned guaranteed bandwidth to support their synchronous needs. Asynchronous traffic is lower priority and is sent only if time permits. It is proved analytically that the FDDI access protocol provides all stations on the ring with equal access to the channel to transmit asynchronous frames, regardless of the relative sizes of synchronous bandwidth allocations for individual stations. Analytic results are supported with data from simulation runs.

Johnson, M. J.↗

On the synchronizability and detectability of random PPM sequences

The problem of synchronization and detection of random pulse-position-modulation (PPM) sequences is investigated under the assumption of perfect slot synchronization. Maximum-likelihood PPM symbol synchronization and receiver algorithms are derived that make decisions based both on soft as well as hard data; these algorithms are seen to be easily implementable. Bounds derived on the symbol error probability as well as the probability of false synchronization indicate the existence of a rather severe performance floor, which can easily be the limiting factor in the overall system performance. The performance floor is inherent in the PPM format and random data and becomes more serious as the PPM alphabet size Q is increased. A way to eliminate the performance floor is suggested by inserting special PPM symbols in the random data stream.

Georghiades, Costas N.↗

Throughput analysis of the IEEE 802.4 token bus standard under heavy load

It has become clear in the last few years that there is a trend towards integrated digital services. Parallel to the development of public Integrated Services Digital Network (ISDN) is service integration in the local area (e.g., a campus, a building, an aircraft). The types of services to be integrated depend very much on the specific local environment. However, applications tend to generate data traffic belonging to one of two classes. According to IEEE 802.4 terminology, the first major class of traffic is termed synchronous, such as packetized voice and data generated from other applications with real-time constraints, and the second class is called asynchronous which includes most computer data traffic such as file transfer or facsimile. The IEEE 802.4 token bus protocol which was designed to support both synchronous and asynchronous traffic is examined. The protocol is basically a timer-controlled token bus access scheme. By a suitable choice of the design parameters, it can be shown that access delay is bounded for synchronous traffic. As well, the bandwidth allocated to asynchronous traffic can be controlled. A throughput analysis of the protocol under heavy load with constant channel occupation of synchronous traffic and constant token-passing times is presented.

Pang, Joseph↗

On the synchronizability and detectability of random PPM sequences

The problem of synchronization and detection of random pulse-position-modulation (PPM) sequences is investigated under the assumption of perfect slot synchronization. Maximum likelihood PPM symbol synchronization and receiver algorithms are derived that make decisions based both on soft as well as hard data; these algorithms are seen to be easily implementable. Bounds were derived on the symbol error probability as well as the probability of false synchronization that indicate the existence of a rather severe performance floor, which can easily be the limiting factor in the overall system performance. The performance floor is inherent in the PPM format and random data and becomes more serious as the PPM alphabet size Q is increased. A way to eliminate the performance floor is suggested by inserting special PPM symbols in the random data stream.

Georghiades, Costas N.↗

Parallel discrete-event simulation of FCFS stochastic queueing networks

Physical systems are inherently parallel. Intuition suggests that simulations of these systems may be amenable to parallel execution. The parallel execution of a discrete-event simulation requires careful synchronization of processes in order to ensure the execution's correctness; this synchronization can degrade performance. Largely negative results were recently reported in a study which used a well-known synchronization method on queueing network simulations. Discussed here is a synchronization method (appointments), which has proven itself to be effective on simulations of FCFS queueing networks. The key concept behind appointments is the provision of lookahead. Lookahead is a prediction on a processor's future behavior, based on an analysis of the processor's simulation state. It is shown how lookahead can be computed for FCFS queueing network simulations, give performance data that demonstrates the method's effectiveness under moderate to heavy loads, and discuss performance tradeoffs between the quality of lookahead, and the cost of computing lookahead.

Nicol, David M.↗

Laser Doppler velocimeter multiplexer interface for simultaneous measured events

An Laser Doppler Velocimeter multiplexer interface (20) includes an event pulse synchronizer (162), which synchronizes data pulses from events A, B and C. Clock control (164) is connected to receive timing information on the data pushes from the synchronizer (162). Displays (24, 26, 28) are connected to receive clock signals from the clock control (164) for indicating a data rate for each of the measured events A, B and C. Display (3) is connected to receive clock signals form the clock control (164) to indicate a coincidence rate between data pulses for any selected combination of the measured events A, B and C. A multiplexer (156) receives the data pulses from the events A, B and C and rate data from the clock control (164). Multiplexer (156) has output (180) for supplying the data pulses and rate data to a single input of a data processing system. A multiplexer control (158) is connected to supply control signals to the multiplexer (156) for selecting the event data pulses and the rate data for output from the multiplexer (156). Multiplexer control (158) receives start signals from the pulse synchronizer (162) and user selected inputs for desired outputs from the multiplexer (156).

Dean R Harrison↗

Alternative majority-voting methods for real-time computing systems

Two techniques that provide a compromise between the high time overhead in maintaining synchronous voting and the difficulty of combining results in asynchronous voting are proposed. These techniques are specifically suited for real-time applications with a single-source/single-sink structure that need instantaneous error masking. They provide a compromise between a tightly synchronized system in which the synchronization overhead can be quite high, and an asynchronous system which lacks suitable algorithms for combining the output data. Both quorum-majority voting (QMV) and compare-majority voting (CMV) are most applicable to distributed real-time systems with single-source/single-sink tasks. All real-time systems eventually have to resolve their outputs into a single action at some stage. The development of the advanced information processing system (AIPS) and other similar systems serve to emphasize the importance of these techniques. Time bounds suggest that it is possible to reduce the overhead for quorum-majority voting to below that for synchronous voting. All the bounds assume that the computation phase is nonpreemptive and that there is no multitasking.

Shin, Kang G.↗