Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Chemical Characterization Results for Tank 40 Sludge Batch 10 Waste Acceptance Product Specifications (WAPS) Sample

A 3-L sample (HTF-40-23-24) obtained from Tank 40 following transfer of Tank 51 to achieve the final Sludge Batch 10 processing composition was received by Savannah River National Laboratory (SRNL). SRNL was tasked with characterization of the sample in accordance with requirements for reporting the Waste Acceptance Product Specifications. A representative subsample, approximately 500 mL, was prepared by continuously agitating the 3-L sample via a mixing blade inserted into the bottle. This subsample was then used for the chemical and physical characterization reported here. This characterization includes the following: (1) Supernate and slurry density; (2) Weight percent solids; (3) Mercury Analysis (supernate and slurry); (4) Anions; (5) Total Organic/Inorganic Carbon; (6) Free Hydroxide; (7) Other Base; (8) Elementals; (9) Volatile Organic Analysis and Semi-volatile Organic Analysis; and (10) Fissile Radionuclides and Uranium Enrichment. The results of this physical and chemical characterization of the sample are documented in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Extraction, Scrub, and Strip Test Results for the IBC BOBCalix Solvent Samples

A second vendor for solvent extraction components has been chosen for use at the Salt Waste Processing Facility (SWPF). IBC Advanced Technologies (IBC) has provided samples of their BOBCalix, as well as complete solvent. These samples were tested for quality assurance purposes to ensure their use at SWPF is acceptable. Two Extraction, Scrub, and Strip (ESS) tests were performed on solvent samples from IBC. The purpose of testing these samples was to determine if the solvents are displaying the correct extraction and stripping behavior with cesium.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of Long-Term Analyses of the Salt (Macro) Batch 11 Tank 21H Qualification Sample

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Salt Waste Processing Facility (SWPF) Salt Batch 11. This document reports the long-term results of the analyses of the sample of Tank 21H. Analysis of this sample indicates that the material does not display any unusual characteristics or observations, such as visually apparent solids. However, the sample was dark colored. This report satisfies Deliverable 3 of the Technical Task Request (TTR).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Results of Long-Term Analyses of the Salt (Macro) Batch 11 Tank 21H Qualification Sample

Savannah River National Laboratory (SRNL) analyzed samples from Tank 21H in support of qualification of Salt Waste Processing Facility (SWPF) Salt Batch 11. This document reports the long-term results of the analyses of the sample of Tank 21H. Analysis of this sample indicates that the material does not display any unusual characteristics or observations, such as visually apparent solids. However, the sample was dark colored. This report satisfies Deliverable 3 of the Technical Task Request (TTR). This revision adds a further triplicate analysis for 129 I content.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Soil Sampling Results for Delineating BH-056 for Partial Closure of Solid Waste Management Unit #16

The U.S. Department of Energy/National Nuclear Security Administration (DOE/NNSA) and National Technology & Engineering Solutions of Sandia, LLC (NTESS), the management and operating contractor for Sandia National Laboratories/California (SNL/CA), has prepared this addendum to Soil Sampling Results for Closure of a Portion of Solid Waste Management Unit #16 to report the results of additional soil sampling relating to the closure of a portion of Solid Waste Management Unit (SWMU) #16. This additional sampling was in response to a request by the San Francisco Bay Regional Water Quality Control Board (SFRWQCB) in their letters dated February 16 and August 18, 2022 relating to the detection of the benzidine above the defined project action level in a soil sample collected adjacent to the sanitary sewer line in borehole BH-056 (SFRWQCB, 2022A; 2022b).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Hanford Waste Treatment Plant Effluent Management Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The Hanford Tank Waste Treatment and Immobilization Plant Effluent Management Facility (EMF) stack monitor location was qualified using a combination of scale model stacks to mitigate the risk of identifying that the sampling location does not meet the qualification criteria on the full-scale stack. The LV-S1 scale model stack was used as a baseline, augmented by the LB-S1 and LV-S2 scale model stacks to address the Direct Feed Low Activity Waste Effluent Management Facility Vessel Vent Process (DVP) injection into the main Active Confinement Ventilation (ACV) system duct. As required by the American National Standards Institute/Health Physics Society (ANSI/HPS) N13.1-1999 standard, the scale model and its sampling locations were geometrically similar to the actual stack, and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the product of the hydraulic diameter and mean velocity (DV) of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. The LV-S1, LB-S1, and LV-S2 scale model stack tests have met the criteria of the ANSI/HPS N13.1-1999 standard to demonstrate the stack sampling locations are well mixed. Verification tests of the EMF stack were performed at normal operating conditions. The minimum 1/6 DV value and the maximum 6 DV value from the scale model testing determine the range of stack flow rates for which the full-scale stack may be operated while remaining in compliance with the stack verification criterion. A practical range for the full-scale stack qualification uses the average DV through 6 DV from the scale model tests to compute the corresponding flow rates. Table S1 lists the operating flow rate along with the average and maximum qualified stack flow rate based on the LV-S1 scale model DV values. The operating flow is below the maximum qualified stack flow, which means that the scale model test results are acceptable for stack qualification. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be ≤20°. Second, the velocity uniformity at the full-scale stack must be ≤20% coefficient of variance (COV). Finally, the velocity uniformity results for the actual and scale model stack tests must agree within 5% COV. These criteria were met through the full-scale stack test at the EMF. Flow angle results were <5°; all flow angle results were within the ≤20° criterion. The velocity uniformity results for each test condition ranged between 2.2% COV and 4.3% COV, all of which were within the range of the target % COV values from the scale model tests on the LV-S1, LB-S1, and LV S2 scale models. Based on these stack verification test results, the EMF filtered exhaust stack sampling location meets the qualification criteria provided in the ANSI/HPS N13.1-1999 standard for all planned fan operating configurations. This includes each combination of ACV fans with DVP exhausters. Further changes to the system configuration or operating conditions that are outside the qualified flow rates described in this report may require additional tests or analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Compressed sensing methods with applications to advanced air sampling

Environmental sampling methods developed by the Savannah River National Laboratory (SRNL) employ collectors with sorbent media tubes set at various locations to collect airborne emissions. Laboratory analyses of these tubes results in one-dimensional signals regarding what chemicals are being released and transported within the atmosphere. The analysis process is time consuming especially when analyzing a full year’s worth of tubes (hourly sample collection results in nearly 9,000 tubes per year). Using a signal processing method such as compressed sensing allows for recreation of the full signal while greatly reducing the number of analyzed samples required. Due to the sparsity of data retrieved from the air tubes, it is possible to use measurements a fraction of the size of the original data to gain much of the same information. This would improve the overall time and cost of analysis when modeling one-dimensional sampling signals.

54 ENVIRONMENTAL SCIENCES↗

Understanding Biases in Sample Preparation Techniques for Coupled Scanning Electron Microscopy and MAMA PuO 2 Morphological Analysis

In this project, the scanning electron microscopy (SEM) sampling method used during the statistical design study (SDS) was investigated to determine if any sampling biases were present in the analyzed data. Using standard particle size distribution powders from the National Institute of Standards and Technology (NIST 1984 standard reference material) with the origin wet dispersion method, it was determined that a bias to smaller particles was present. This was supported by theoretical calculations using Stokes’ law to determine the settling rate of spherical particles of roughly the same size and mass as those found in the SDS. Based on the theoretical calculations, it was determined that the settling rate for each of the 76 powder sets in the SDS could be unique based on specific particle shape and mass distributions, making a universal correction factor/formula not applicable. Therefore, priority shifted to developing an improved wet dispersion method that significantly reduced the particle settling rate for all particle size and shapes. This was achieved by replacing the original solvent (isopropyl alcohol) with a heavy liquid (lithium heteropolytungstates), which dramatically slowed the settling rate and allowed for the capture of a suitable homogeneous aliquot. SEM imaging and Morphological Analysis for Material Attribution (MAMA) software analysis were conducted on the NIST standard, and the SEM/MAMA data were compared to data captured by a dynamic image analysis particle size analyzer. The resulting data confirmed that the new wet dispersion method does indeed deliver an improved representative aliquot to the SEM stub. For instance, in the NIST certificate, the average particle size is ~17.1 µm ± 2.2 µm with a normal distribution. The initial wet dispersion method resulted in a drastically reduced average particle size of 6.1 µm in addition to a non-representative heavy bi-modal distribution whereas the improved LST wet dispersion method resulting in an average particle size that was much closer to the NIST certificate (12.7 µm) with a similar normal distribution. Although the improved method was still short of the NIST certificate average, atomic force microscopy analysis determined that the resulting ~20-25% reduction in size was due to particles sinking into the carbon sticky tape used for SEM imaging. It is believed that that this bias can be calibrated in a much more predicable manner than the original settling rate bias. In addition, the matching normal distribution curves between the NIST certificate and the heavy liquid method indicate a much-improved representative aliquot has been sampled and imaged. A surrogate CeO 2 powder was used to reflect PuO 2 more accurately and to aid in implementing radiological controls and shielding. The resulting data sets from the SEM/MAMA method and the particle size analyzer give almost identical average particle sizes and particle distribution statistics. Future work will re-analyze several select runs from the SDS to determine if morphological signatures can be found with the improved sampling method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compressed Sensing Methods with Applications to Advanced Air Sampling [Poster]

Environmental sampling methods developed by the Savannah River National Laboratory (SRNL) employ collectors with sorbent media tubes set at various locations to collect airborne emissions. Laboratory analyses of these tubes results in one-dimensional signals regarding what chemicals are being released and transported within the atmosphere. The analysis process is time consuming especially when analyzing a full year’s worth of tubes (hourly sample collection results in nearly 9,000 tubes per year). Using a signal processing method such as compressed sensing allows for recreation of the full signal while greatly reducing the number of analyzed samples required. Due to the sparsity of data retrieved from the air tubes, it is possible to use measurements a fraction of the size of the original data to gain much of the same information. This would improve the overall time and cost of analysis when modeling one-dimensional sampling signals.

Campbell, Cassidy [Savannah River National Laborat↗

Filtration and Leach Testing for REDOX Sludge and S-Saltcake Actual Waste Sample Composites

A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.( ) The test program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Under test plan TP-RPP-WTP-467, eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. Under this test plan, a waste-testing program was implemented that included: • Homogenizing the archive samples by group as defined in the test plan • Characterizing the homogenized sample groups • Performing parametric leaching testing on each group for compounds of interest • Performing bench-top filtration/leaching tests in the hot cell for each group to simulate filtration and leaching activities if they occurred in the UFP2 vessel of the WTP Pretreatment Facility. This report focuses on filtration/leaching tests performed on two of the eight waste composite samples and follow-on parametric tests to support aluminum leaching results from those tests.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization and Leach Testing for PUREX Cladding Waste Sludge (Group 3) and REDOX Cladding Waste Sludge (Group 4) Actual Waste Sample Composites

A testing program evaluating actual tank waste was developed in response to Task 4 from the M-12 External Flowsheet Review Team (EFRT) issue response plan.(a) The testing program was subdivided into logical increments. The bulk water-insoluble solid wastes that are anticipated to be delivered to the Waste Treatment and Immobilization Plant (WTP) were identified according to type such that the actual waste testing could be targeted to the relevant categories. Eight broad waste groupings were defined. Samples available from the 222S archive were identified and obtained for testing. The actual wastetesting program included homogenizing the samples by group, characterizing the solids and aqueous phases, and performing parametric leaching tests. Two of the eight defined groups—plutonium-uranium extraction (PUREX) cladding waste sludge (Group 3, or CWP) and reduction-oxidation (REDOX) cladding waste sludge (Group 4, or CWR)—are the subjects of this report. Both the Group 3 and 4 waste composites were anticipated to be high in gibbsite, requiring caustic leaching. Characterization of the composite Group 3 and Group 4 waste samples confirmed them to be high in gibbsite. The focus of the Group 3 and 4 testing was on determining the behavior of gibbsite during caustic leaching. The waste-type definition, archived sample conditions, homogenization activities, characterization (physical, chemical, radioisotope, and crystal habit), and caustic leaching behavior as functions of time, temperature, and hydroxide concentration are discussed in this report. Testing was conducted according to TP-RPP-WTP-467.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

RESULTS FOR THE MAY 19, 2010 INADVERTENT TRANSFER TO THE SALTSTONE DISPOSAL FACILITY SLURRY: SAMPLE ANALYTICAL RESULTS

This report details the chemical analysis results for the characterization of the May 19, 2010 inadvertent transfer from the Saltstone Production Facility (SPF) to the Saltstone Disposal Facility (SDF). On May 19, 2010, the Saltstone Processing Facility (SPF) inadvertently transferred approximately 1800 gallons of untreated low-level salt solution from the salt feed tank (SFT) to Cell F of Vault 4. The transfer was identified and during safe configuration shutdown, approximately 70 gallons of SFT material was left in the Saltstone hopper. After the shutdown, the material in the hopper was undisturbed, while the SFT has received approximately 1400 gallons of drain water from the Vault 4 bleed system. The drain water path from Vault 4 to the SFT does not include the hopper (Figure 1); therefore it was determined that the material remaining in the hopper was the most representative sample of the salt solution transferred to the vault. To complete item No.5 of Reference 1, Savannah River National Laboratory (SRNL) was asked to analyze the liquid sample retrieved from the hopper for pH, and metals identified by the Resource Conservation and Recovery Act (RCRA). SRNL prepared a report to complete item No.5 and determine the hazardous nature of the transfer. Waste Solidification Engineering then instructed SRNL to provide a more detailed analysis of the slurried sample to assist in the determination of the portion of Tank 50 waste in the hopper sample.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The Effects of Herbarium Specimen Characteristics on Short-Read NGS Sequencing Success in Nearly 8000 Specimens: Old, Degraded Samples Have Lower DNA Yields but Consistent Sequencing Success

Phylogenetic datasets are now commonly generated using short-read sequencing technologies unhampered by degraded DNA, such as that often extracted from herbarium specimens. The compatibility of these methods with herbarium specimens has precipitated an increase in broad sampling of herbarium specimens for inclusion in phylogenetic studies. Understanding which sample characteristics are predictive of sequencing success can guide researchers in the selection of tissues and specimens most likely to yield good results. Multiple recent studies have considered the relationship between sample characteristics and DNA yield and sequence capture success. Here we report an analysis of the relationship between sample characteristics and sequencing success for nearly 8,000 herbarium specimens. This study, the largest of its kind, is also the first to include a measure of specimen quality (“greenness”) as a predictor of DNA sequencing success. We found that taxonomic group and source herbarium are strong predictors of both DNA yield and sequencing success and that the most important specimen characteristics for predicting success differ for DNA yield and sequencing: greenness was the strongest predictor of DNA yield, and age was the strongest predictor of proportion-on-target reads recovered. Surprisingly, the relationship between age and proportion-on-target reads is the inverse of expectations; older specimens performed slightly better in our capture-based protocols. We also found that DNA yield itself is not a strong predictor of sequencing success. Most literature on DNA sequencing from herbarium specimens considers specimen selection for optimal DNA extraction success, which we find to be an inappropriate metric for predicting success using next-generation sequencing technologies.

54 ENVIRONMENTAL SCIENCES↗

Near-Complete Sampling of Forest Structure from High-Density Drone Lidar Demonstrated by Ray Tracing

Drone lidar has the potential to provide detailed measurements of vertical forest structure throughout large areas, but a systematic evaluation of unsampled forest structure in comparison to independent reference data has not been performed. Here, we used ray tracing on a high-resolution voxel grid to quantify sampling variation in a temperate mountain forest in the southwest Czech Republic. We decoupled the impact of pulse density and scan-angle range on the likelihood of generating a return using spatially and temporally coincident TLS data. We show three ways that a return can fail to be generated in the presence of vegetation: first, voxels could be searched without producing a return, even when vegetation is present; second, voxels could be shadowed (occluded) by other material in the beam path, preventing a pulse from searching a given voxel; and third, some voxels were unsearched because no pulse was fired in that direction. We found that all three types existed, and that the proportion of each of them varied with pulse density and scan-angle range throughout the canopy height profile. Across the entire data set, 98.1% of voxels known to contain vegetation from a combination of coincident drone lidar and TLS data were searched by high-density drone lidar, and 81.8% of voxels that were occupied by vegetation generated at least one return. By decoupling the impacts of pulse density and scan angle range, we found that sampling completeness was more sensitive to pulse density than to scan-angle range. There are important differences in the causes of sampling variation that change with pulse density, scan-angle range, and canopy height. Our findings demonstrate the value of ray tracing to quantifying sampling completeness in drone lidar.

47 OTHER INSTRUMENTATION↗

Sample Preparation and Experimental Design for In Situ Multi-Beam Transmission Electron Microscopy Irradiation Experiments

We discuss the need to understand materials exposed to overlapping extreme environments such as high temperature, radiation, or mechanical stress. When these stressors are combined there may be synergistic effects that enable unique microstructural evolution mechanisms to activate. Understanding of these mechanisms is necessary for the input and refinement of predictive models and critical for engineering of next generation materials. The basic physics and underlying mechanisms require advanced tools to be investigated. The in situ ion irradiation transmission electron microscope (I 3 TEM) is designed to explore these principles. To quantitatively probe the complex dynamic interactions in materials, careful preparation of samples and consideration of experimental design is required. Particular handling or preparation of samples can easily introduce damage or features that obfuscate the measurements. There is no one correct way to prepare a sample; however, many mistakes can be made. The most common errors and things to consider are highlighted within. The I 3 TEM has many adjustable variables and a large potential experimental space, therefore it is best to design experiments with a specific scientific question or questions in mind. Experiments have been performed on large number of sample geometries, material classes, and with many irradiation conditions. The following are a subset of examples that demonstrate unique in situ capabilities utilizing the I 3 TEM. Au nanoparticles prepared by drop casting have been used to investigate the effects of single ion strikes. Au thin films have been used in studies on the effects of multibeam irradiation on microstructure evolution. Zr films have been exposed to irradiation and mechanical tension to examine creep. Ag nanopillars were subjected to simultaneous high temperature, mechanical compression, and ion irradiation to study irradiation induced creep as well. These results impact fields including: structural materials, nuclear energy, energy storage, catalysis, and microelectronics in space environments.

47 OTHER INSTRUMENTATION↗

THE CHANDRA COSMOS-LEGACY SURVEY: THE z > 3 SAMPLE

We present the largest high-redshift (3 < z < 6.85) sample of X-ray-selected active galactic nuclei (AGNs) on a contiguous field, using sources detected in the Chandra COSMOS-Legacy survey. The sample contains 174 sources, 87 with spectroscopic redshift and the other 87 with photometric redshift (z {sub phot}). In this work, we treat z {sub phot} as a probability-weighted sum of contributions, adding to our sample the contribution of sources with z {sub phot} < 3 but z {sub phot} probability distribution >0 at z > 3. We compute the number counts in the observed 0.5–2 keV band, finding a decline in the number of sources at z > 3 and constraining phenomenological models of the X-ray background. We compute the AGN space density at z > 3 in two different luminosity bins. At higher luminosities (log L (2–10 keV) > 44.1 erg s{sup −1}), the space density declines exponentially, dropping by a factor of ∼20 from z ∼ 3 to z ∼ 6. The observed decline is ∼80% steeper at lower luminosities (43.55 erg s{sup −1} < logL(2–10 keV) < 44.1 erg s{sup −1}) from z ∼ 3 to z ∼ 4.5. We study the space density evolution dividing our sample into optically classified Type 1 and Type 2 AGNs. At log L (2–10 keV) > 44.1 erg s{sup −1}, unobscured and obscured objects may have different evolution with redshift, with the obscured component being three times higher at z ∼ 5. Finally, we compare our space density with predictions of quasar activation merger models, whose calibration is based on optically luminous AGNs. These models significantly overpredict the number of expected AGNs at log L (2–10 keV) > 44.1 erg s{sup −1} with respect to our data.

79 ASTRONOMY AND ASTROPHYSICS↗

GMRT Low-frequency Imaging of an Extended Sample of X-shaped Radio Galaxies

We present a low-frequency imaging study of an extended sample of X-shaped radio sources using the Giant Metrewave Radio Telescope (GMRT) at two frequencies (610 and 240 MHz). The sources were drawn from a Very Large Array Radio Images of the Sky at Twenty-Centimeters (FIRST) selected sample and extend an initial GMRT study at the same frequencies of 12 X-shaped radio galaxies predominantly from the 3CR catalog (Lal and Rao 2007). Both the intensity maps and spectral index maps of the 16 newly observed sources are presented. With the combined sample of 28 X-shaped radio sources, we found no systematic differences in the spectral properties of the higher surface brightness, active lobes versus the lower surface brightness, or off-axis emission. The properties of the combined sample are discussed, including the possible role of a twin active galactic nuclei model in the formation of such objects.

79 ASTRONOMY AND ASTROPHYSICS↗

Parsec-scale Properties of Steep- and Flat-spectrum Extragalactic Radio Sources from a VLBA Survey of a Complete North Polar Cap Sample

We observed with the Very Long Baseline Array (VLBA) at 2.3 and 8.6 GHz a complete flux-density-limited sample of 482 radio sources with decl. > +75° brighter than 200 mJy at 1.4 GHz drawn from the NVSS catalog. A total of 34% of the sources show parsec-scale emission above the flux density detection limit of 30 mJy; their accurate positions and parsec-scale structure parameters are determined. Among all the sources detected at least at the shortest VLBA baselines, the majority, or 72%, have a steep single-dish spectrum. The fraction of the sources with a detectable parsec-scale structure is above 95% among the flat-spectrum objects and close to 25% among the steep-spectrum objects. We identified 82 compact steep-spectrum source candidates, which make up 17% of the sample; most of them are reported for the first time. The compactness and the brightness temperature of the sources in our sample show a positive correlation with single-dish and VLBA spectral indices. All the sources with a significant 8 GHz variability were detected by the VLBA snapshot observations, which independently confirmed their compactness. We demonstrated that 54% of the sources detected by the VLBA at 2.3 GHz in our sample have a steep VLBA spectrum. The compact radio emission of these sources is likely dominated by optically thin jets or mini-lobes, not by an opaque jet core. These results show that future VLBI surveys aimed at searching for new sources with parsec-scale structure should include not only flat-spectrum sources but also steep-spectrum ones in order to reach an acceptable level of completeness.

47 OTHER INSTRUMENTATION↗