Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Update on Ultrasonic Thermometry Development at Idaho National Laboratory

The Idaho National Laboratory (INL) has initiated an effort to evaluate the viability of using ultrasonic thermometry technology as an improved sensor for detecting temperature during irradiation testing of advanced fuels proposed within the Fuel Cycle Research and Development (FCR&D) program sponsored by the U.S. Department of Energy (US DOE). Ultrasonic thermometers (UTs) work on the principle that the speed at which sound travels through a material (acoustic velocity) is dependent on the temperature of the material. UTs have several advantages over other types of temperature sensors . UTs can be made very small, as the sensor consists only of a small diameter rod which may or may not require a sheath. Measurements may be made up to very high temperature (near the melting point of the sensor material) and, as no electrical insulation is required, shunting effects observed in traditional high temperature thermocouple applications are avoided. Most attractive, however, is the ability to introduce multiple acoustic discontinuities into the sensor, as this enables temperature profiling with a single sensor. The current paper presents initial results from FCR&D UT development efforts. These developments include improved methods for fabricating magnetostrictive transducers and joining them to waveguides, characterization of candidate sensor materials appropriate for use in FCR&D fuels irradiations (both ceramic fuels in inert gas and sodium bonded metallic fuels), enhanced signal processing techniques, and tests to determine potential accuracy and resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMPARISON OF CHAOTIC AND FRACTAL PROPERTIES OF POLAR FACULAE WITH SUNSPOT ACTIVITY

The solar magnetic activity is governed by a complex dynamo mechanism and exhibits a nonlinear dissipation behavior in nature. The chaotic and fractal properties of solar time series are of great importance to understanding the solar dynamo actions, especially with regard to the nonlinear dynamo theories. In the present work, several nonlinear analysis approaches are proposed to investigate the nonlinear dynamical behavior of the polar faculae and sunspot activity for the time interval from 1951 August to 1998 December. The following prominent results are found: (1) both the high- and the low-latitude solar activity are governed by a three-dimensional chaotic attractor, and the chaotic behavior of polar faculae is the most complex, followed by that of the sunspot areas, and then the sunspot numbers; (2) both the high- and low-latitude solar activity exhibit a high degree of persistent behavior, and their fractal nature is due to such long-range correlation; (3) the solar magnetic activity cycle is predictable in nature, but the high-accuracy prediction should only be done for short- to mid-term due to its intrinsically dynamical complexity. With the help of the Babcock–Leighton dynamo model, we suggest that the nonlinear coupling of the polar magnetic fields with strong active-region fields exhibits a complex manner, causing the statistical similarities and differences between the polar faculae and the sunspot-related indicators.

79 ASTRONOMY AND ASTROPHYSICS↗

Gelatin as a new humidity sensing material: Characterization and limitations

The goal of this work is to assert the utility of collagen and its denatured counterpart gelatin as cost-effective alternatives to existing sensing layers comprised of polymers. Rather than producing a material that will need to be discarded or recycled, collagen, as a by-product of the meat and leather industry, could be repurposed. This work examines the feasibility of using collagen as a sensing layer. Planar electrodes were patterned with lift-off process to work with the natural characteristics of gelatin by utilizing metal vapor deposition, spin coating, and photolithography. Characterization methods have also been optimized through the creation of specialized humidity chambers that isolate specific characteristics such as response time, accuracy, and hysteresis. Collagen-based sensors are found to have a sensitivity to moisture in the range of 0.065 pF/%RH. Diffusion characteristics were also analyzed with the diffusion coefficient found to be 2.5 × 10{sup −5} cm{sup 2}/s. Absorption and desorption times were found to be 20 seconds and 8 seconds, respectively. Hysteresis present in the data is attributed to temperature cross-sensitivity. Ultimately, the utility of collagen as a dielectric sensing material is, in part, due to its fibrous macrostructures as well its hydrophilic sites along the peptide chains. Gelatin was patterned between and below interdigitated copper electrodes and tested as a relative humidity sensor. This work shows that gelatin, which is inexpensive, widely available, and easy to process, can be an effective dielectric sensing polymer for capacitive-type relative humidity sensors.

36 MATERIALS SCIENCE↗

A DETAILED LOOK AT CHEMICAL ABUNDANCES IN MAGELLANIC CLOUD PLANETARY NEBULAE. I. THE SMALL MAGELLANIC CLOUD

We present an analysis of elemental abundances of He, N, O, Ne, S, and Ar in Magellanic Cloud planetary nebulae (PNe) and focus initially on 14 PNe in the Small Magellanic Cloud (SMC). We derive the abundances from a combination of deep, high-dispersion optical spectra, as well as mid-infrared (IR) spectra from the Spitzer Space Telescope. A detailed comparison with prior SMC PN studies shows that significant variations in relative emission-line flux determinations among the authors, lead to systematic discrepancies in derived elemental abundances between studies that are {approx_gt}0.15 dex, in spite of similar analysis methods. We use ionic abundances derived from IR emission lines, including those from ionization stages not observable in the optical, to examine the accuracy of some commonly used recipes for ionization correction factors (ICFs). These ICFs, which were developed for ions observed in the optical and ultraviolet, relate ionic abundances to total elemental abundances. We find that most of these ICFs work very well even in the limit of substantially sub-solar metallicities, except for PNe with very high ionization. Our abundance analysis shows enhancements of He and N that are predicted from prior dredge-up processes of the progenitors on the asymptotic giant branch (AGB), as well as the well-known correlations among O, Ne, S, and Ar that are little affected by nucleosynthesis in this mass range. We identify MG 8 as an interesting limiting case of a PN central star with a {approx}3.5 M{sub sun} progenitor in which hot-bottom burning did not occur in its prior AGB evolution. We find no evidence for O depletion in the progenitor AGB stars via the O-N cycle, which is consistent with predictions for lower-mass stars. We also find low S/O ratios relative to SMC H II regions, with a deficit comparable to what has been found for Galactic PNe. Finally, the elemental abundances of one object, SMP-SMC 11, are more typical of SMC H II regions, which raises some doubt about its classification as a PN.

79 ASTRONOMY AND ASTROPHYSICS↗

The effects of structure anisotropy on lensing observables in an exact general relativistic setting for precision cosmology

The study of relativistic, higher order, and nonlinear effects has become necessary in recent years in the pursuit of precision cosmology. We develop and apply here a framework to study gravitational lensing in exact models in general relativity that are not restricted to homogeneity and isotropy, and where full nonlinearity and relativistic effects are thus naturally included. We apply the framework to a specific, anisotropic galaxy cluster model which is based on a modified NFW halo density profile and described by the Szekeres metric. We examine the effects of increasing levels of anisotropy in the galaxy cluster on lensing observables like the convergence and shear for various lensing geometries, finding a strong nonlinear response in both the convergence and shear for rays passing through anisotropic regions of the cluster. Deviation from the expected values in a spherically symmetric structure are asymmetric with respect to path direction and thus will persist as a statistical effect when averaged over some ensemble of such clusters. The resulting relative difference in various geometries can be as large as approximately 2%, 8%, and 24% in the measure of convergence (1−κ) for levels of anisotropy of 5%, 10%, and 15%, respectively, as a fraction of total cluster mass. For the total magnitude of shear, the relative difference can grow near the center of the structure to be as large as 15%, 32%, and 44% for the same levels of anisotropy, averaged over the two extreme geometries. The convergence is impacted most strongly for rays which pass in directions along the axis of maximum dipole anisotropy in the structure, while the shear is most strongly impacted for rays which pass in directions orthogonal to this axis, as expected. The rich features found in the lensing signal due to anisotropic substructure are nearly entirely lost when one treats the cluster in the traditional FLRW lensing framework. These effects due to anisotropic structures are thus likely to impact lensing measurements and must be fully examined in an era of precision cosmology.

79 ASTRONOMY AND ASTROPHYSICS↗

Improving Accuracy and Precision in Gross Alpha and Beta Counting with Proportional Detectors

Following ambiguous results of an intercomparison exercise in 2004, we have reevaluated the sample preparation, measurement procedures and data treatment for gross alpha and beta counting. It was found that the Portuguese standards NP 4332:1996 and NP 4330:1996 do not provide enough background for correct treatment of data. This paper describes the improvements made in gross alpha and beta activities measurement with proportional detectors in simultaneous mode. These improvements include a crosstalk correction both on counting and in the minimum detectable activity; the use of adequate statistical tools for data analysis; the use of QC charts to control the stability of the detectors and the background and, attention to the traceability of results. The calibration curves were computed with an appropriate number of replicates and with a throughout evaluation of the uncertainty budget. Based on this model, we established new criteria to report results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of at-wavelength metrology for x-ray optics at the ALS

The comprehensive realization of the exciting advantages of new third- and forth-generation synchrotron radiation light sources requires concomitant development of reflecting and diffractive x-ray optics capable of micro- and nano-focusing, brightness preservation, and super high resolution. The fabrication, tuning, and alignment of the optics are impossible without adequate metrology instrumentation, methods, and techniques. While the accuracy of ex situ optical metrology at the Advanced Light Source (ALS) has reached a state-of-the-art level, wavefront control on beamlines is often limited by environmental and systematic alignment factors, and inadequate in situ feedback. At ALS beamline 5.3.1, we are developing broadly applicable, high-accuracy, in situ, at-wavelength wavefront measurement techniques to surpass 100-nrad slope measurement accuracy for Kirkpatrick-Baez (KB) mirrors. The at-wavelength methodology we are developing relies on a series of tests with increasing accuracy and sensitivity. Geometric Hartmann tests, performed with a scanning illuminated sub-aperture determine the wavefront slope across the full mirror aperture. Shearing interferometry techniques use coherent illumination and provide higher sensitivity wavefront measurements. Combining these techniques with high precision optical metrology and experimental methods will enable us to provide in situ setting and alignment of bendable x-ray optics to realize diffraction-limited, sub 50 nm focusing at beamlines. We describe here details of the metrology beamline endstation, the x-ray beam diagnostic system, and original experimental techniques that have already allowed us to precisely set a bendable KB mirror to achieve a focused spot size of 150 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

On estimations of maximum and average interfacial temperature rise in sliding elliptical contacts

his study considers the approaches of Blok and Jaeger for the estimation of maximum and average temperatures in sliding elliptical contacts with both uniform and semi-ellipsoidal (Hertzian) heat distributions. The accuracy of each of these methods, which are based on single-point temperature matching between contacting bodies, is assessed relative to a numerical solution of the heat partition problem developed in a previous work, which imposed temperature matching at all nodal points. Comparisons are made for a wide range of Peclet numbers, as well as for moderate ranges of thermal conductivity ratio and elliptical ratio. It is found that the application of Blok's hypothesis yields remarkably accurate predictions of the maximum interfacial temperature, with typical errors less than 3%, whereas the hypothesis of Jaeger leads to predictions of the average interfacial temperature that have typical errors of around 6%. The authors also assess the accuracy of approximate formula developed by Tian and Kennedy to predict the maximum temperature at the interface for the case of sliding circular contacts and find the error to be no more than 2.6% for the full range of Peclet number. Further, the authors of the current study use fundamental heat source solutions developed by Tian and Kennedy to arrive at formulae for average temperature rise for circular contacts that are analogous to the Tian and Kennedy maximum temperature rise formulae. It is found that the formulae for computing the average interfacial temperature rise are also quite accurate, but have slightly more error than the maximum temperature rise formulae. Finally, in the present work, extensions are suggested to the maximum and average temperature rise formulae of Tian and Kennedy to include the effects of elliptical contact geometry. It is found that these formulae are at least 91% accurate for elliptical ratios between 0.4 and 5.0.

99 GENERAL AND MISCELLANEOUS↗

Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer

Purpose: The goal of any dosimeter is to be as accurate as possible when measuring absolute dose to compare with calculated dose. This limits the uncertainties associated with the dosimeter itself and allows the task of dose QA to focus on detecting errors in the treatment planning (TPS) and/or delivery systems. This work introduces enhancements to the measurement accuracy of a 3D dosimeter comprised of a helical plane of diodes in a volumetric phantom. Methods: We describe the methods and derivations of new corrections that account for repetition rate dependence, intrinsic relative sensitivity per diode, field size dependence based on the dynamic field size determination, and positional correction. Required and described is an accurate ''virtual inclinometer'' algorithm. The system allows for calibrating the array directly against an ion chamber signal collected with high angular resolution. These enhancements are quantitatively validated using several strategies including ion chamber measurements taken using a ''blank'' plastic shell mimicking the actual phantom, and comparison to high resolution dose calculations for a variety of fields: static, simple arcs, and VMAT. A number of sophisticated treatment planning algorithms were benchmarked against ion chamber measurements for their ability to handle a large air cavity in the phantom. Results: Each calibration correction is quantified and presented vs its independent variable(s). The virtual inclinometer is validated by direct comparison to the gantry angle vs time data from machine log files. The effects of the calibration are quantified and improvements are seen in the dose agreement with the ion chamber reference measurements and with the TPS calculations. These improved agreements are a result of removing prior limitations and assumptions in the calibration methodology. Average gamma analysis passing rates for VMAT plans based on the AAPM TG-119 report are 98.4 and 93.3% for the 3%/3 mm and 2%/2 mm dose-error/distance to agreement threshold criteria, respectively, with the global dose-error normalization. With the local dose-error normalization, the average passing rates are reduced to 94.6 and 85.7% for the 3%/3 mm and 2%/2 mm criteria, respectively. Some algorithms in the convolution/superposition family are not sufficiently accurate in predicting the exit dose in the presence of a 15 cm diameter air cavity. Conclusions: Introduction of the improved calibration methodology, enabled by a robust virtual inclinometer algorithm, improves the accuracy of the dosimeter's absolute dose measurements. With our treatment planning and delivery chain, gamma analysis passing rates for the VMAT plans based on the AAPM TG-119 report are expected to be above 91% and average at about 95% level for {gamma}(3%/3 mm) with the local dose-error normalization. This stringent comparison methodology is more indicative of the true VMAT system commissioning accuracy compared to the often quoted dose-error normalization to a single high value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Technical Note: Motion-perturbation method applied to dosimetry of dynamic MLC target tracking—A proof-of-concept

Purpose: Previous studies show that dose to a moving target can be estimated using 4D measurement-guided dose reconstruction based on a process called virtual motion simulation, or VMS. A potential extension of VMS is to estimate dose during dynamic multileaf collimator (MLC)-tracking treatments. The authors introduce a modified VMS method and quantify its performance as proof-of-concept for tracking applications. Methods: Direct measurements with a moving biplanar diode array were used to verify accuracy of the VMS dose estimates. A tracking environment for variably sized circular MLC apertures was simulated by sending preprogrammed control points to the MLC while simultaneously moving the accelerator treatment table. Sensitivity of the method to simulated tracking latency (0–700 ms) was also studied. Potential applicability of VMS to fast changing beam apertures was evaluated by modeling, based on the demonstrated dependence of the cumulative dose on the temporal dose gradient. Results: When physical and virtual latencies were matched, the agreement rates (2% global/2 mm gamma) between the VMS and the biplanar dosimeter were above 96%. When compared to their own reference dose (0 induced latency), the agreement rates for VMS and biplanar array track closely up to 200 ms of induced latency with 10% low-dose cutoff threshold and 300 ms with 50% cutoff. Time-resolved measurements suggest that even in the modulated beams, the error in the cumulative dose introduced by the 200 ms VMS time resolution is not likely to exceed 0.5%. Conclusions: Based on current results and prior benchmarks of VMS accuracy, the authors postulate that this approach should be applicable to any MLC-tracking treatments where leaf speeds do not exceed those of the current Varian accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-44: Development of a Room Laser Based Real-Time Alignment Monitoring System Using An Array of Photodiodes

Purpose: To develop a real-time alignment monitoring system (RAMS) to compensate for the limitations of the conventional room laser based alignment system, and to verify the feasibility of the RAMS. Methods: The RAMS was composed of a room laser sensing array (RLSA), an analog-todigital converter, and a control PC. In the RLSA, seven photodiodes (each in 1 mm width) are arranged in a pattern that the RAMS provides alignment in 1 mm resolution. It works based on detecting laser light aligned on one of photodiodes. When misaligned, the laser would match with different photodiode(s) giving signal at unexpected location. Thus, how much displaced can be determined. To verify the reproducibility of the system with respect to time as well as repeated set-ups, temporal reproducibility and repeatability test was conducted. The accuracy of the system was tested by obtaining detection signals with varying laser-match positions. Results: The signal of the RAMS was found to be stable with respect to time. The repeatability test resulted in a maximum coefficient of variance of 1.14%, suggesting that the signal of the RAMS was stable over repeated set-ups. In the accuracy test, signals between when the laser was aligned and notaligned with any of sensors could be distinguished by signal intensity. The signals of not-aligned sensors were always below 75% of the signal of the aligned sensor. It was confirmed that the system could detect 1 mm of movement by monitoring the pattern of signals, and could observe the movement of the system in real-time. Conclusion: We developed a room laser based alignment monitoring system. The feasibility test verified that the system is capable of quantitative alignment monitoring in real time. The system is relatively simple, not expensive, and considered to be easily incorporated into conventional room laser systems for real-time alignment monitoring. This research was supported by the Mid-career Researcher Program through NRF funded by the Ministry of Science, ICT & Future Planning of Korea (NRF-2014R1A2A1A10050270) and by the Radiation Technology R&D program through the National Research Foundation of Korea funded by the Ministry of Science, ICT & Future Planning (No. 2013M2A2A7038291)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Use of Physics to Improve Solar Forecast: Physics-Informed Persistence Models for Simultaneously Forecasting GHI, DNI, and DHI

Observation-based statistical models have been widely used in forecasting solar energy; however, existing models often lack a clear relation to physics and are limited largely to global horizontal irradiance (GHI) forecasts over relatively short time horizons (< 1 hour). Incorporating physics into observation-based models, increasing forecast time horizons and developing a model system for forecasting not only GHI but also direct normal irradiance (DNI) and diffuse horizontal irradiance (DHI) remain challenging, especially under cloudy conditions because of complex cloud-radiation interactions. This work attempts to address these challenges by developing a hierarchy of four new physics-informed persistence models that can be used to simultaneously forecast GHI, DNI and DHI. The decade-long measurements (1998 to 2014) at the U.S. Department of Energy's Atmospheric Radiation Measurement (ARM)'s Southern Great Plains (SGP) Central Facility site are used to evaluate the performance of the new models. Overall, the results show that the new physics-informed forecast models generally outperform the simple and smart persistence models, and improve the forecast accuracy at lead times from 1.25 hours up to 6 hours. Further analysis reveals that the forecast error is highly related to the error and temporal variability of the assumed cloud predictor. The best model for forecasting different radiative components can be explained by the relationship between solar irradiances and cloud properties.

54 ENVIRONMENTAL SCIENCES↗

An efficient method for the determination of fourth virial coefficient with Lennard-Jones (12-6) potential and its application

In this work, a new theoretical approach is proposed for calculating fourth virial coefficient with Lennard-Jones potential. The established algorithm can be used to evaluate the thermodynamics properties and the intermolecular interaction potentials of liquids and gases with an improved accuracy. Note that the evaluation of the high-order virial coefficients is very valuable for accurate calculation of thermodynamic parameters. By using the suggested method, the fourth virial coefficient of CH{sub 4}, Ar, C{sub 2}H{sub 6} and SF{sub 6} molecules are evaluated. The calculation results are useful for accurate interpretation of the experimental data and of the determination of related physical properties.

97 MATHEMATICS AND COMPUTING↗

Survey and Analysis of Weather Data for Building Energy Simulations

In recent years, calibrated energy modeling of residential and commercial buildings has gained importance in a retrofit-dominated market. Accurate weather data plays an important role in this calibration process and projected energy savings. It would be ideal to measure weather data at the building location to capture relevant microclimate variation but this is generally considered cost-prohibitive. There are data sources publicly available with high temporal sampling rates but at relatively poor geospatial sampling locations. To overcome this limitation, there are a growing number of service providers that claim to provide real time and historical weather data for 20-35 km2 grid across the globe. Unfortunately, there is limited documentation from 3rd-party sources attesting to the accuracy of this data. This paper compares provided weather characteristics with data collected from a weather station inaccessible to the service providers. Monthly average dry bulb temperature; relative humidity; direct, diffuse and horizontal solar radiation; and wind speed are statistically compared. Moreover, we ascertain the relative contributions of each weather variable and its impact on building loads. Annual simulations are calculated for three different building types, including a closely monitored and automated energy efficient research building. The comparison shows that the difference for an individual variable can be as high as 90%. In addition, annual building energy consumption can vary by 7% while monthly building loads can vary by 40% as a function of the provided location s weather data.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analytic variance estimates of Swank and Fano factors

Purpose: Variance estimates for detector energy resolution metrics can be used as stopping criteria in Monte Carlo simulations for the purpose of ensuring a small uncertainty of those metrics and for the design of variance reduction techniques. Methods: The authors derive an estimate for the variance of two energy resolution metrics, the Swank factor and the Fano factor, in terms of statistical moments that can be accumulated without significant computational overhead. The authors examine the accuracy of these two estimators and demonstrate how the estimates of the coefficient of variation of the Swank and Fano factors behave with data from a Monte Carlo simulation of an indirect x-ray imaging detector. Results: The authors' analyses suggest that the accuracy of their variance estimators is appropriate for estimating the actual variances of the Swank and Fano factors for a variety of distributions of detector outputs. Conclusions: The variance estimators derived in this work provide a computationally convenient way to estimate the error or coefficient of variation of the Swank and Fano factors during Monte Carlo simulations of radiation imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Modeling Spatial Distribution of Snow Water Equivalent by Combining Meteorological and Satellite Data with Lidar Maps

Abstract An accurate characterization of the water content of snowpack, or snow water equivalent (SWE), is necessary to quantify water availability and constrain hydrologic and land surface models. Recently, airborne observations (e.g., lidar) have emerged as a promising method to accurately quantify SWE at high resolutions (scales of ∼100 m and finer). However, the frequency of these observations is very low, typically once or twice per season in the Rocky Mountains of Colorado. Here, we present a machine learning framework that is based on random forests to model temporally sparse lidar-derived SWE, enabling estimation of SWE at unmapped time points. We approximated the physical processes governing snow accumulation and melt as well as snow characteristics by obtaining 15 different variables from gridded estimates of precipitation, temperature, surface reflectance, elevation, and canopy. Results showed that, in the Rocky Mountains of Colorado, our framework is capable of modeling SWE with a higher accuracy when compared with estimates generated by the Snow Data Assimilation System (SNODAS). The mean value of the coefficient of determination R 2 using our approach was 0.57, and the root-mean-square error (RMSE) was 13 cm, which was a significant improvement over SNODAS (mean R 2 = 0.13; RMSE = 20 cm). We explored the relative importance of the input variables and observed that, at the spatial resolution of 800 m, meteorological variables are more important drivers of predictive accuracy than surface variables that characterize the properties of snow on the ground. This research provides a framework to expand the applicability of lidar-derived SWE to unmapped time points. Significance Statement Snowpack is the main source of freshwater for close to 2 billion people globally and needs to be estimated accurately. Mountainous snowpack is highly variable and is challenging to quantify. Recently, lidar technology has been employed to observe snow in great detail, but it is costly and can only be used sparingly. To counter that, we use machine learning to estimate snowpack when lidar data are not available. We approximate the processes that govern snowpack by incorporating meteorological and satellite data. We found that variables associated with precipitation and temperature have more predictive power than variables that characterize snowpack properties. Our work helps to improve snowpack estimation, which is critical for sustainable management of water resources.

54 ENVIRONMENTAL SCIENCES↗

Nonlinearities in modified gravity cosmology: Signatures of modified gravity in the nonlinear matter power spectrum

A large fraction of cosmological information on dark energy and gravity is encoded in the nonlinear regime. Precision cosmology thus requires precision modeling of nonlinearities in general dark energy and modified gravity models. We modify the Gadget-2 code and run a series of N-body simulations on modified gravity cosmology to study the nonlinearities. The modified gravity model that we investigate in the present paper is characterized by a single parameter {zeta}, which determines the enhancement of particle acceleration with respect to general relativity (GR), given the identical mass distribution ({zeta}=1 in GR). The first nonlinear statistics we investigate is the nonlinear matter power spectrum at k < or approx. 3h/Mpc, which is the relevant range for robust weak lensing power spectrum modeling at l < or approx. 2000. In this study, we focus on the relative difference in the nonlinear power spectra at corresponding redshifts where different gravity models have the same linear power spectra. This particular statistics highlights the imprint of modified gravity in the nonlinear regime and the importance of including the nonlinear regime in testing GR. By design, it is less susceptible to the sample variance and numerical artifacts. We adopt a mass assignment method based on wavelet to improve the power spectrum measurement. We run a series of tests to determine the suitable simulation specifications (particle number, box size, and initial redshift). We find that, the nonlinear power spectra can differ by {approx}30% for 10% deviation from GR (|{zeta}-1|=0.1) where the rms density fluctuations reach 10. This large difference, on one hand, shows the richness of information on gravity in the corresponding scales, and on the other hand, invalidates simple extrapolations of some existing fitting formulae to modified gravity cosmology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗