Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REFRIGERATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Optimization of the autoclave preparation process for improving resistant starch content in rice grains

Abstract The autoclave preparation process to increase the content of resistant starch (RS) in rice grains was optimized, and the results showed that the optimal preparation process was obtained with a water content of 41.63%, a pH of 5.95, an autoclave time of 60.96 min, and a refrigeration time of 17.11 hr. Under these conditions, the theoretical value of RS content in rice grains reached 17.57%. After autoclaving, the estimated glycemic index (EGI) in rice grains was reduced from 78.35 to 66.08 measured after cooking, suggesting that autoclaving was capable of increasing the RS content in rice grains and reducing its EGI value. These results may help spark new concepts and methods for the development of specialized foods for specific populations, such as people with diabetes.

Zheng, Yunzhan↗

Health, safety, and environmental risks from energy production: A year-long reality check

Large-scale carbon dioxide capture and storage (CCS) offers the benefit of reducing CO{sub 2} emissions and thereby mitigating climate change risk, but it will also bring its own health, safety, and environmental risks. Curtis M. Oldenburg, Editor-in-Chief, considers these risks in the context of the broader picture of energy production. Over the last year, there have been major acute health, safety, and environmental (HSE) consequences related to accidents involving energy production from every major primary energy source. These are, in chronological order: (i) the Upper Big Branch (coal) Mine disaster, (ii) the Gulf of Mexico Macondo (oil) well blowout, (iii) the San Bruno (natural gas) pipeline leak and explosion, and (iv) the Fukushima (nuclear) reactor radioactivity releases. Briefly, the Upper Big Branch Mine disaster occurred in West Virginia on April 5, 2010, when natural methane in the mine ignited, causing the deaths of 29 miners, the worst coal mine disaster in the USA since 1970. Fifteen days later, the Macondo oil well in the Gulf of Mexico suffered a blowout, with a gas explosion and fire on the floating drilling platform that killed 11 people. The oil and gas continued to flow out of the well at the seafloor until July 15, 2010, spilling a total of approximately 5 million barrels of oil into the sea. On September 9, 2010, a 30-inch (76-cm) buried, steel, natural gas pipeline in San Bruno, California, leaked gas and exploded in a residential neighborhood, killing 8 people in their homes and burning a total of 38 homes. Flames were up to 1000 ft (300 m) high, and the initial explosion itself reportedly measured 1.1 on the Richter scale. Finally, on March 11, 2011, a magnitude 9.0 earthquake off the coast of Japan's main island, Honshu, caused a tsunami that crippled the backup power and associated cooling systems for six reactor cores and their spent fuel storage tanks at the Fukushima nuclear power plant. At time of writing, workers trying to bring the crisis under control have been exposed to dangerous levels of radiation, and radioactive water and particulates have been released to the sea and atmosphere. These four disasters, all of which occurred within the past 12 months, were not unprecedented; similar events differing only in detail have happened around the world before, and such events will occur again. Today, developed nations primarily use fossil fuels to create affordable energy for comforts such as lighting, heating and air-conditioning, refrigeration, transportation, education, and entertainment, as well as for powering manufacturing, which creates jobs and a wealth of material goods. In addition to the risks of the existing energy infrastructure that have become obvious through these recent disasters, there is also the ongoing risk of climate change that comes from the vast emissions of greenhouse gases, primarily CO{sub 2}, from the burning of fossil fuels. The implementation of CO{sub 2} capture and storage (CCS) will help mitigate CO{sub 2} emissions from fossil fuel energy, but it also carries with it HSE risks. In my personal interactions with the public and with students, the main concern voiced is whether CO{sub 2} could leak out of the deep reservoirs into which it is injected and rise up out of the ground, smothering people and animals at the ground surface. Another concern expressed is that CO{sub 2} pipelines could fail and cause similar gaseous plumes of CO{sub 2}. The widespread concerns about CO{sub 2} leaking out over the ground surface may be inspired by events that have happened within natural systems in equatorial Africa, in Indonesia, and in Italy. Researchers have been investigating a wide variety of HSE risks of geologic CO{sub 2} storage for some time and have determined that wells are the main potential pathways for significant leakage from the deep subsurface. I discuss the acute HSE risks of CO{sub 2} leakage through wells and from pipelines, and compare the behavior of failures in CO{sub 2} wells and pipelines with oil and gas analogues from which most of our experience derives.

54 ENVIRONMENTAL SCIENCES↗

Easy parallel screening of reagent stability, quality control, and metrology in solid phase peptide synthesis (SPPS) and peptide couplings for microarrays

Evaluating the stability of coupling reagents, quality control (QC), and surface functionalization metrology are all critical to the production of high quality peptide microarrays. We describe a broadly applicable screening technique for evaluating the fidelity of solid phase peptide synthesis (SPPS), the stability of activation/coupling reagents, and a microarray surface metrology tool. This technique was used to assess the stability of the activation reagent 1-{[1-(Cyano-2-ethoxy-2-oxo-ethylidenaminooxy)dimethylamino-morpholinomethylene]}methaneaminiumHexafluorophosphate (COMU) (Sigma-Aldrich, St. Louis, MO, USA) by SPPS of Leu-Enkephalin (YGGFL) or the coupling of commercially synthesized YGGFL peptides to (3-aminopropyl)triethyoxysilane-modified glass surfaces. Coupling efficiency was quantitated by fluorescence signaling based on immunoreactivity of the YGGFL motif. It was concluded that COMU solutions should be prepared fresh and used within 5 h when stored at ~23 °C and not beyond 24 h if stored refrigerated, both in closed containers. Caveats to gauging COMU stability by absorption spectroscopy are discussed. Commercial YGGFL peptides needed independent QC, due to immunoreactivity variations for the same sequence synthesized by different vendors. This technique is useful in evaluating the stability of other activation/coupling reagents besides COMU and as a metrology tool for SPPS and peptide microarrays.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Magneto-Optical Sensing Beyond the Shot Noise Limit

Magneto-optical sensors including spin noise spectroscopies and magneto-optical Kerr effect microscopies are now ubiquitous tools for materials characterization that can provide new understanding of spin dynamics, hyperfine interactions, spin-orbit interactions, and charge-carrier g-factors. Both interferometric and intensity-difference measurements can provide photon-shot-noise-limited sensitivity, but further improvements in sensitivity with classical resources require either increased laser power that can induce unwanted heating and electronic perturbations or increased measurement times that can obscure out-of-equilibrium dynamics and slow experimental throughput. Proof-of-principle measurements have already demonstrated quantum enhanced spin noise measurements with a squeezed readout field that are likely to be critical to the nonperturbative characterization of spin excitations in quantum materials that emerge at low temperatures. Here, a truncated nonlinear interferometric readout for low-temperature magneto-optical Kerr effect and related magneto-optical microscopies that is accessible with today's quantum optical resources is proposed. 10 nrad/$\sqrt{Hz}$ sensitivity is achievable with optical power as small as 1 µW. As a result, measurements may be performed at temperatures as low as 83 mK in commercially available dilution refrigerators. This combination of high sensitivity and low operating temperature is impossible to achieve with any classical measurement. The quantum advantage for the proposed measurements persists even in the limit of large loss and small squeezing parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effects of Cobalt on the Crystalline Structures of the Ni-Mn-In Giant Magnetocaloric Heusler Alloys

The giant inverse magnetocaloric effect driven by a merged magneto-structural transformations in Ni-Mn-In-Co Heusler alloys, makes them highly promising as solid state refrigerants near room temperature. Knowledge of the crystallographic behavior of these alloys at a broad temperature range is critical to the understanding of the giant magnetocaloric effect. In this study, three Ni-Mn-In-Co alloys were investigated by neutron and synchrotron diffraction techniques. The chemical compositions of the alloys, determined by the Rutherford Backscattering Spectrometry (RBS) technique, were Ni 41 Mn 39 In 12 Co 8 , Ni 48 Mn 34 In 12 Co 6 and Ni 52 Mn 25 In 16 Co 7 . The austenitic (A) phase of all three alloys was cubic L2 1 (Fm$ \overline{3}\ $m). Martensitic (M) phase of the Ni 41 Mn 39 In 12 Co 8 alloy was a mix of 8M and 6M modulated monoclinic structures, while the other two alloys had a M composed of a mix of 7 M and 5 M modulated monoclinic structures. All modulated structures belong to the P 1 2/m 1 space group. Site occupancy refinements of the A phases of all three alloys, revealed that almost all the Co atoms (~97%) occupy the regular Ni (8c) sites. In the studied temperature range (50–250 K) of the M phase of the Ni 41 Mn 39 In 12 Co 8 alloy has very low magnetization. Also, no antiferromagnetic ordring was observed in the neutron diffraction refinement of the M phase. Therefore by eliminating the possibilities of ferromagnetism and antiferromagnetism, it is concluded that the M phase of the Ni 41 Mn 39 In 12 Co 8 alloy is spin glass.

Madiligama, A↗

The X-ray Integral Field Unit at the end of the Athena reformulation phase

The Athena mission entered a redefinition phase in July 2022, driven by the imperative to reduce the mission cost at completion for the European Space Agency below an acceptable target, while maintaining the flagship nature of its science return. This notably called for a complete redesign of the X-ray Integral Field Unit (X-IFU) cryogenic architecture towards a simpler active cooling chain. Passive cooling via successive radiative panels at spacecraft level is now used to provide a 50 K thermal environment to an X-IFU owned cryostat. 4.5 K cooling is achieved via a single remote active cryocooler unit, while a multi-stage Adiabatic Demagnetization Refrigerator ensures heat lift down to the 50 mK required by the detectors. Amidst these changes, the core concept of the readout chain remains robust, employing Transition Edge Sensor microcalorimeters and a SQUID-based Time-Division Multiplexing scheme. Noteworthy is the introduction of a slower pixel. This enables an increase in the multiplexing factor (from 34 to 48) without compromising the instrument energy resolution, hence keeping significant system margins to the new 4 eV resolution requirement. This allows reducing the number of channels by more than a factor two, and thus the resource demands on the system, while keeping a 4’ field of view (compared to 5’ before). Here, in this article, we will give an overview of this new architecture, before detailing its anticipated performances. Finally, we will present the new X-IFU schedule, with its short term focus on demonstration activities towards a mission adoption in early 2027.

Peille, Philippe [Centre National d’Etudes Spatial↗

Speed of Sound Measurements of Binary Mixtures of Hydrofluorocarbons [Pentafluoroethane (R-125), 1,1-Difluoroethane (R-152a), or 1,1,1,2,3,3,3-Heptafluoropropane (R-227ea)] with Hydrofluoroolefins [2,3,3,3-Tetrafluoropropene (R-1234yf) or trans-1,3,3,3-Tetrafluoropropene (R-1234ze(E))]

In this article, speed of sound data measured using a dual-path pulse-echo instrument are reported for three binary refrigerant mixtures, R-125/1234yf, R-1234yf/152a, and R-1234ze(E)/227ea, at compositions of (0.33/0.67) and (0.67/0.33) mole fraction. The speed of sound was studied at temperatures ranging from 230 K to 345 K from pressures slightly above the bubble point curve up to 20 MPa for the mixtures containing R-1234yf and 49 MPa for the R-1234ze(E)/227ea mixtures. The relative combined expanded speed of sound uncertainty ranged from 0.039 % to 0.317 % with a mean uncertainty over all state points of less than 0.10 %. The reported data are compared to the most recent mixture models in REFPROP for each blend studied. Comparisons of available mixture models for the R-125/1234yf and R-1234yf/152a blends exhibit average absolute deviation values ranging from 0.10 % to 0.27 %, and the average absolute deviations for R-1234ze(E)/227ea blends range from 0.62 % to 0.94 %. The comparisons show that only minor adjustments are required to the R-125/1234yf and R-1234yf/152a mixture models to represent the speed of sound data within its uncertainty. However, significant adjustments are needed to improve the current mixture models for the R-1234ze(E)/227ea blend. Deficiencies with the R-1234ze(E)/227ea mixture model are not unexpected since it (1) utilizes a pure-fluid EOS R-1234ze(E) that has been shown to inaccurately represent R-1234ze(E) speed of sound values and (2) uses binary interaction parameters for the chemically similar mixture of R-1234yf/227ea.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The LiteBIRD Satellite Mission: Sub-Kelvin Instrument

Inflation is the leading theory of the first instant of the universe. Inflation, which postulates that the universe underwent a period of rapid expansion an instant after its birth, provides convincing explanation for cosmological observations. Recent advancements in detector technology have opened opportunities to explore primordial gravitational waves generated by the inflation through “B-mode” (divergent-free) polarization pattern embedded in the cosmic microwave background anisotropies. If detected, these signals would provide strong evidence for inflation, point to the correct model for inflation, and open a window to physics at ultra-high energies. LiteBIRD is a satellite mission with a goal of detecting degree-and-larger-angular-scale B-mode polarization. LiteBIRD will observe at the second Lagrange point with a 400 mm diameter telescope and 2622 detectors. It will survey the entire sky with 15 frequency bands from 40 to 400 GHz to measure and subtract foregrounds. The US LiteBIRD team is proposing to deliver sub-Kelvin instruments that include detectors and readout electronics. A lenslet-coupled sinuous antenna array will cover low-frequency bands (40–235 GHz) with four frequency arrangements of trichroic pixels. An orthomode-transducer-coupled corrugated horn array will cover high-frequency bands (280–402 GHz) with three types of single frequency detectors. The detectors will be made with transition edge sensor (TES) bolometers cooled to a 100 milli-Kelvin base temperature by an adiabatic demagnetization refrigerator. The TES bolometers will be read out using digital frequency multiplexing with Superconducting QUantum Interference Device (SQUID) amplifiers. Up to 78 bolometers will be multiplexed with a single SQUID amplifier. Lastly, we report on the sub-Kelvin instrument design and ongoing developments for the LiteBIRD mission.

79 ASTRONOMY AND ASTROPHYSICS↗

TES X-ray Spectrometer at SLAC LCLS-II

We are building a transition edge sensor (TES) X-ray spectrometer for the Linac Coherent Light Source (LCLS-II) at SLAC National Accelerator Laboratory (SLAC) to coincide with new upgrades for this free electron laser facility. This new X-ray spectrometer will have 1000 TES pixels with 0.5 eV energy resolution for soft X-rays below 1 keV. Multiplexing will be done with microwave SQUID resonators and new specialized electronic hardware developed at SLAC. This spectrometer will use a dilution refrigerator to achieve lower operating temperatures than previous TES spectrometers and will be coupled to the liquid jet endstation at LCLS-II. The spectrometer is designed to operate at much higher count rates than previous TES X-ray spectrometers to take advantage of the high repetition rate of the LCLS-II. Science applications will utilize the high photon collection efficiency and throughput, high energy resolution, as well as its ability to simultaneously measure its full calibrated energy range.

47 OTHER INSTRUMENTATION↗

Updated design of the CMB polarization experiment satellite LiteBIRD

Recent developments of transition-edge sensors (TESs), based on extensive experience in ground-based experiments, have been making the sensor techniques mature enough for their application on future satellite CMB polarization experiments. LiteBIRD is in the most advanced phase among such future satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with JAXA's H3 rocket. It will accommodate more than 4000 TESs in focal planes of reflective low-frequency and refractive medium-and-high-frequency telescopes in order to detect a signature imprinted on the cosmic microwave background (CMB) by the primordial gravitational waves predicted in cosmic inflation. The total wide frequency coverage between 34GHz and 448GHz enables us to extract such weak spiral polarization patterns through the precise subtraction of our Galaxy's foreground emission by using spectral differences among CMB and foreground signals. Telescopes are cooled down to 5Kelvin for suppressing thermal noise and contain polarization modulators with transmissive half-wave plates at individual apertures for separating sky polarization signals from artificial polarization and for mitigating from instrumental 1/f noise. Passive cooling by using V-grooves supports active cooling with mechanical coolers as well as adiabatic demagnetization refrigerators. Sky observations from the second Sun-Earth Lagrangian point, L2, are planned for three years. An international collaboration between Japan, USA, Canada, and Europe is sharing various roles. In May 2019, the Institute of Space and Astronautical Science (ISAS), JAXA selected LiteBIRD as the strategic large mission No. 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of Transition Edge Sensors for the Simons Observatory

The Simons Observatory is building both large (6 m) and small (0.5 m) aperture telescopes in the Atacama Desert in Chile to observe the cosmic microwave background CMB radiation with unprecedented sensitivity. Simons Observatory telescopes in total will use over 60,000 transition edge sensor (TES) detectors spanning center frequencies between 27 and 285 GHz and operating near 100 mK. TES devices have been fabricated for the Simons Observatory by NIST, Berkeley, and HYPRES/SeeQC corporation. Iterations of these devices have been tested cryogenically in order to inform the fabrication of further devices, which will culminate in the final TES designs to be deployed in the field. The detailed design specifications have been independently iterated at each fabrication facility for particular detector frequencies. We present test results for prototype devices, with emphasis on NIST high frequency detectors. A dilution refrigerator was used to achieve the required temperatures. Measurements were taken both with 4-lead resistance measurements and with a time-domain Superconducting Quantum Interference Device (SQUID) multiplexer system. The SQUID readout measurements include analysis of current versus voltage (IV) curves at various temperatures, square wave bias step measurements, and detector noise measurements. Lastly, normal resistance, superconducting critical temperature, saturation power, thermal and natural time constants, and thermal properties of the devices are extracted from these measurements.

47 OTHER INSTRUMENTATION↗

Observation of Long-Lived UV-Induced Fluorescence from Environmental Materials Using the HVeV Detector as Developed for SuperCDMS

Here, we describe recent experiments using a SuperCDMS HVeV single-charge sensitive detector illuminated with an ultraviolet LED (275 nm) and a monochromatic laser(650 nm) using a dual fiber optic system installed in a small dilution refrigerator at Stanford University. We observed a population of fluorescence background events after UV exposure but not after exposure to the laser source. The fluorescence was likely due to scattered UV photons absorbed outside the detector. We discuss the possibility of fluorescence being a contributor to the low energy excess background observed in above-ground Dark Matter experiments.

36 MATERIALS SCIENCE↗

The Simons Observatory: Magnetic Shielding Measurements for the Universal Multiplexing Module

The Simons Observatory (SO) includes four telescopes that will measure the temperature and polarization of the cosmic microwave background using over 60,000 highly sensitive transition-edge bolometers (TES). These multichroic TES bolometers are read out by a microwave RF SQUID multiplexing system with a multiplexing factor of 910. Given that both TESes and SQUIDs are susceptible to magnetic field pickup and that it is hard to predict how they will respond to such fields, it is important to characterize the magnetic response of these systems empirically. This information can then be used to limit spurious signals by informing magnetic shielding designs for the detectors and readout. This paper focuses on measurements of magnetic pickup with different magnetic shielding configurations for the SO universal multiplexing module (UMM), which contains the SQUIDs, associated resonators, and TES bias circuit. The magnetic pickup of a prototype UMM was tested under three shielding configurations: no shielding (copper packaging), aluminum packaging for the UMM, and a tin/lead-plated shield surrounding the entire dilution refrigerator 100 mK cold stage. We also present measurements of the pickup in the UMM when aluminum feedhorns are installed. The measurements show that the aluminum packaging outperforms the copper packaging by a shielding factor of 8-10, and adding the tin/lead-plated 1K shield further increases the relative shielding factor in the aluminum configuration by 1-2 orders of magnitude. Furthermore, the addition of feedhorns provides a factor of 30 improvement when the tin/lead shield is not installed and a factor of 5 improvement when it is.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strong Correlation Between the Magnetocaloric Properties of Nanotubes of La{sub 0.325}Pr{sub 0.3}Ca{sub 0.375}MnO{sub 3} and their Diameters

Under 0.01 T applied magnetic field variation, the calculation of magnetocaloric properties for 200 and 800 nm nanotubes of La{sub 0.325}Pr{sub 0.3}Ca{sub 0.375}MnO{sub 3} (LPCMO) perovskite such as magnetic entropy change, full-width at half-maximum (δT FWHM), relative cooling power, and magnetic specific heat change have been done. Magnetocaloric properties of 800-nm nanotubes of LPCMO is more than MCE of 200 nm ones. LPCMO nanotubes have hopeful application for magnetic refrigeration (MR) in an extended high-temperature range due to high values of δT{sub FWHM}. Therefore, nanotubes of LPCMO are very significant for MR applications, especially nitrogen liquefier.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural, Magnetic and Magnetocaloric Properties of High-Energy Ball-Milled Gd{sub 5}Si{sub 2}Ge{sub 2}B{sub 0.05} Alloy

Structural, magnetic and magnetocaloric properties of Gd{sub 5}Si{sub 2}Ge{sub 2}B{sub 0.05} alloy, ball milled for different time intervals in the range of 2–50 h were studied. The x-ray powder diffraction analysis of the alloy prior to milling revealed the presence of mixed orthorhombic and monoclinic phases at room temperature. For a milling duration up to 15 h, the alloy powder displayed crystalline nature. Upon further milling, the alloy powder started to lose the crystallinity and after 50 h of milling, the alloy powder displayed amorphous nature. The average particle size of milled samples was found to decrease with increase in milling time. The saturation magnetization value of the bulk alloy 80 emu/g was found to decrease with increase in milling time due to structural disorder. The transition temperature of the milled alloy powder was found to be around 295 K and the transition was found to become broader with increase in milling time. A maximum isothermal entropy change (ΔS{sub max}) of ∼12 J/kg K was obtained in bulk alloy. For a milling duration of 2 h, a marginal decrease of ΔS{sub max} (∼11 J/kg K) was obtained. Whereas, for higher milling durations, (≥ 15 h) a significant decrease in ΔS{sub max} values were observed. However, the broad operating temperature range of the milled powders can be exploited for magnetic refrigeration applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Comparative Study of Magnetocaloric Effect in La{sub 0.67}Ca{sub 0.20}Sr{sub 0.13}MnO{sub 3} Manganite Prepared by Sol-Gel Method and Spark Plasma Sintering

The La{sub 0.67}Ca{sub 0.20}Sr{sub 0.13}MnO{sub 3} nanoparticles and bulks were prepared by using sol-gel method (SGM) and spark plasma sintering (SPS), respectively. The X-ray diffraction analysis indicates each sample crystal in a single rhombohedral perovskite structure (space group R 3-bar c). The Curie temperature is slightly improved and the phase transition is sharpened after processing with SPS. The enhancement of magnetocaloric effect (MCE) is also observed in the samples prepared by SPS. For a field change of 3 T, the maximum isothermal entropy change is improved by 32 and 117% when different sintering temperatures and sintering pressures are applied. The magnetic phase transition and MCE can be well described by the Landau theory. The present studies suggest that the perovskite bulks prepared by SPS could be useful for the application of magnetic refrigeration.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Prediction of Magnetocaloric Effect in La{sub 0.67}Pb{sub 0.33}(Mn{sub 1−x}Co{sub x})O{sub 3} Compounds (x = 0.01, 0.06, 0.1 and 0.15)

The magnetocaloric properties for the Co-doped La{sub 0.67}Pb{sub 0.33}(Mn{sub 1−x}Co{sub x})O{sub 3} samples with x= 0.01, 0.06, 0.1 and 0.15 under a 0.005 T magnetic field have been theoretically investigated and compared with experimental results. It has been found that the Co doping in this system decreases lightly the magnetocaloric properties. Moreover, the results of Co doping indicate that the magnetocaloric effect in this system is tunable, which is beneficial for manipulating magnetocaloric refrigeration that occurs in various temperature ranges. This makes the La{sub 0.67}Pb{sub 0.33}(Mn{sub 1−x}Co{sub x})O{sub 3} samples potential candidates for practical applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗