THE INNER ENVELOPE AND DISK OF L1527 REVEALED: GEMINI L'-BAND-SCATTERED LIGHT IMAGING

We present high-resolution L'-band imaging of the inner scattered light structure of Class 0 protostar L1527 IRS (IRAS 04368+2557) taken with the Gemini North telescope. The central point-source-like feature seen in Spitzer Space Telescope IRAC images is resolved in the Gemini image into a compact bipolar structure with a narrow dark lane in the center. Two scattered light lobes are extended {approx}1.''8 (200 AU) perpendicular to the direction of the outflow and {approx}2.''5 (350 AU) along the outflow axis; the narrow dark lane between the scattered light lobes is {approx}0.''45 (60 AU) thick. The observations are consistent with our initial modeling of a bright inner cavity separated by a dark lane due to extinction along the line of sight of the central protostar by the disk. The bright, compact scattered light might be due to complex inner structure generated by the outflow, as suggested in our first paper, or it may more likely be the upper layers of the disk forming from infalling matter.

79 ASTRONOMY AND ASTROPHYSICS↗

MAGNETIC FIELD CONFIGURATION AT THE GALACTIC CENTER INVESTIGATED BY WIDE-FIELD NEAR-INFRARED POLARIMETRY: TRANSITION FROM A TOROIDAL TO A POLOIDAL MAGNETIC FIELD

We present a large-scale view of the magnetic field (MF) in the central 2{sup 0} x 2{sup 0} region of our Galaxy. The polarization of point sources has been measured in the J, H, and K{sub S} bands using the near-infrared polarimetric camera SIRPOL on the 1.4 m Infrared Survey Facility telescope. Comparing the Stokes parameters between high extinction stars and relatively low extinction ones, we obtain polarization originating from magnetically aligned dust grains in the central few hundred parsecs of our Galaxy. We find that near the Galactic plane, the MF is almost parallel to the Galactic plane (i.e., toroidal configuration), but at high Galactic latitudes (|b | >0.{sup 0}4) the field is nearly perpendicular to the plane (i.e., poloidal configuration). This is the first detection of a smooth transition of the large-scale MF configuration in this region.

79 ASTRONOMY AND ASTROPHYSICS↗

Nordstroem gravity coupled to point particles in (1+1) dimensions

We consider a (1+1)-dimensional model of general relativity that is based on a geometric theory of gravity due to Nordstroem. We show that the theory is formally equivalent to scalar field theory in flat spacetime, and we exploit this equivalence to solve the initial value problem for the system for the case of point particle sources. We illustrate our results by obtaining several example solutions to the model.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Strong three-body decays of {Lambda}{sub c}(2940){sup +} in a hadronic molecule picture

The {Lambda}{sub c}(2940){sup +} baryon with quantum numbers J{sup P}=(1/2){sup +} is considered as a hadronic molecule composed of a nucleon and D{sup *} meson. We give predictions for the width of the strong three-body decay processes {Lambda}{sub c}(2940){sup +}{yields}{Lambda}{sub c}(2286){sup +}{pi}{sup +}{pi}{sup -} and {Lambda}{sub c}(2286){sup +}{pi}{sup 0}{pi}{sup 0} in this interpretation. Upcoming experimental facilities like a Super B factory at KEK or LHCb might be able to provide data on these decay modes.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The Radiochemical Analysis of Gaseous Samples (RAGS) Apparatus for Nuclear Diagnostics at the National Ignition Facility

The RAGS (Radiochemical Analysis of Gaseous Samples) diagnostic apparatus was recently installed at the National Ignition Facility. Following a NIF shot, RAGS is used to pump the gas load from the NIF chamber for purification and isolation of the noble gases. After collection, the activated gaseous species are counted via gamma spectroscopy for measurement of the capsule areal density and fuel-ablator mix. Collection efficiency was determined by injecting a known amount of {sup 135}Xe into the NIF chamber, which was then collected with RAGS. Commissioning was performed with an exploding pusher capsule filled with isotopically enriched {sup 124}Xe and {sup 126}Xe added to the DT gas fill. Activated xenon species were recovered post-shot and counted via gamma spectroscopy. Results from the collection and commissioning tests are presented. The performance of RAGS allows us to establish a noble gas collection method for measurement of noble gas species produced via neutron and charged particle reactions in a NIF capsule.

07 ISOTOPE AND RADIATION SOURCES↗

Dosimetric comparison of {sup 90}Y, {sup 32}P, and {sup 186}Re radiocolloids in craniopharyngioma treatments

Purpose: In the radionuclide treatment of some forms of brain tumors such as craniopharyngiomas, the selection of the appropriate radionuclide for therapy is a key element in treatment planning. The aim was to study the influence by considering the beta-emitter radionuclide dose rate in an intracranial cyst. Methods: Dosimetry was performed using the MCNP4C radiation transport code. Analytical dosimetry was additionally performed using the Loevinger and the Berger formulas in the MATLAB software. Each result was compared under identical conditions. The advantages and disadvantages of using {sup 90}Y versus {sup 32}P and {sup 186}Re were investigated. Results: The dose rate at the inner surface of the cyst wall was estimated to be 400 mGy/h for a 1 MBq/ml concentration of {sup 90}Y. Under identical conditions of treatment, the corresponding dose rates were 300 mGy/h for {sup 32}P and 160 mGy/h for {sup 186}Re. For a well-defined cyst radius and identical wall thickness, higher dose rates resulted for {sup 90}Y. Conclusions: To achieve the same radiological burden, the required amount of physical activity of injectable solution is lower for {sup 32}P. This is found to be a consequence of both the radionuclide physical half-life and the pattern of energy deposition from the emitted radiation. According to the half-life and dose-rate results, {sup 90}Y would be a good substitute for {sup 32}P.

07 ISOTOPE AND RADIATION SOURCES↗

SU-D-19A-01: Can Farmer-Type Ionization Chambers Be Used to Improve the Accuracy of Low-Energy Electron Beam Reference Dosimetry?

Purpose: To investigate the use of cylindrical Farmer-type ionization chambers to improve the accuracy of low-energy electron beam calibration. Historically, these chamber types have not been used in beams with incident energies less than 10 MeV (R{sub 5} {sub 0} < 4.3 cm) because early investigations suggested large (up to 5 %) fluence perturbation factors in these beams, implying that a significant component of uncertainty would be introduced if used for calibration. More recently, the assumptions used to determine perturbation corrections for cylindrical chambers have been questioned. Methods: Measurements are made with cylindrical chambers in Elekta Precise 4, 8 and 18 MeV electron beams. Several chamber types are investigated that employ graphite walls and aluminum electrodes with very similar specifications (NE2571, NE2505/3, FC65-G). Depth-ionization scans are measured in water in the 8 and 18 MeV beams. To reduce uncertainty from chamber positioning, measurements in the 4 MeV beam are made at the reference depth in Virtual Water™. The variability of perturbation factors is quantified by comparing normalized response of various chambers. Results: Normalized ion chamber response varies by less than 0.7 % for similar chambers at average electron energies corresponding to that at the reference depth from 4 or 6 MeV beams. Similarly, normalized measurements made with similar chambers at the reference depth in the 4 MeV beam vary by less than 0.4 %. Absorbed dose calibration coefficients derived from these results are stable within 0.1 % on average over a period of 6 years. Conclusion: These results indicate that the uncertainty associated with differences in fluence perturbations for cylindrical chambers with similar specifications is only 0.2 %. The excellent long-term stability of these chambers in both photon and electron beams suggests that these chambers might offer the best performance for all reference dosimetry applications.

07 ISOTOPE AND RADIATION SOURCES↗

Microdosimetry of proton and carbon ions

Purpose: To investigate microdosimetry properties of 160 MeV/u protons and 290 MeV/u{sup 12}C ion beams in small volumes of diameters 10–100 nm. Methods: Energy distributions of primary particles and nuclear fragments in the beams were calculated from simulations with the general purpose code SHIELD-HIT, while energy depositions by monoenergetic ions in nanometer volumes were obtained from the event-by-event Monte Carlo track structure ion code PITS99 coupled with the electron track structure code KURBUC. Results: The results are presented for frequencies of energy depositions in cylindrical targets of diameters 10–100 nm, dose distributionsyd(y) in lineal energy y, and dose-mean lineal energies y{sup ¯}{sub D}. For monoenergetic ions, the y{sup ¯}{sub D} was found to increase with an increasing target size for high-linear energy transfer (LET) ions, but decrease with an increasing target size for low-LET ions. Compared to the depth dose profile of the ion beams, the maximum of the y{sup ¯}{sub D} depth profile for the 160 MeV proton beam was located at ∼0.5 cm behind the Bragg peak maximum, while the y{sup ¯}{sub D} peak of the 290 MeV/u {sup 12}C beam coincided well with the peak of the absorbed dose profile. Differences between the y{sup ¯}{sub D} and dose-averaged linear energy transfer (LET{sub D}) were large in the proton beam for both target volumes studied, and in the {sup 12}C beam for the 10 nm diameter cylindrical volumes. The y{sup ¯}{sub D} determined for 100 nm diameter cylindrical volumes in the {sup 12}C beam was approximately equal to the LET{sub D}. The contributions from secondary particles to the y{sup ¯}{sub D} of the beams are presented, including the contributions from secondary protons in the proton beam and from fragments with atomic number Z = 1–6 in the {sup 12}C beam. Conclusions: The present investigation provides an insight into differences in energy depositions in subcellular-size volumes when irradiated by proton and carbon ion beams. The results are useful for characterizing ion beams of practical importance for biophysical modeling of radiation-induced DNA damage response and repair in the depth profiles of protons and carbon ions used in radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-328: The Volume Effect Correction of Probe-Type Dosimetric Detectors Derived From the Convolution Model

Purpose: To derive and introduce a new correction factor kV, the “volume effect correction factor”, that accounts for not only the dose averaging over the detector's sensitive volume but also the secondary electron generation and transport inclusive of the disturbance of the field of secondary electrons within the detector. Materials and Methods: Mathematical convolutions and Fourier's convolution theorem have been used. Monte Carlo simulations of photon pencil beams were performed using EGSnrc. Detector constructions were adapted from manufacturers' information. Results: For the calculation of kV, the three basic convolution kernels have to be taken into account: the dose deposition kernel KD(x) (fluence to dose), the photon fluence response kernel KM(x) (photon fluence to detector signal) and the “dose response kernel” K(x) (dose to detector signal). K(x) is calculated from FT[K(x)] = [1/sqrt(2”)]FT[KM(x)]/FT[KD(x)], where the magnitude of kV(x) can be thereby calculated for arbitrary photon beam profiles and the areanormalized K(x). Conclusions: n order to take into account for the dimensions of dosimetric detectors in narrow photon beams, the “volume effect correction factor” kV has been introduced into the fundamental equation of probe-type dosimetry, and the convolution method has proven to be a method for the derivation of its numerical values. For narrow photon beams, whose width is comparable to the secondary electron ranges, kV can reach very high values, but it can be shown that the signals of small diamond detectors are well representing the absorbed dose to water averaged over the detector volume.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-329: Tissue-Equivalent Phantom Materials for Neutron Dosimetry in Proton Therapy

Purpose: To characterize tissue equivalence of phantom materials in terms of secondary neutron production and dose deposition from neutrons produced in radiation therapy phantom materials in the context of proton therapy using Monte Carlo simulations and measurements. Methods: In order to study the influence of material choice on neutron production in therapeutic proton beams, Monte Carlo simulations using the Geant4 and MCNPX-PoliMi transport codes were performed to generate the neutron fields produced by protons of 155 and 200 MeV. A simple irradiation geometry was used to investigate the effect of different materials. The proton beams were stopped in slab phantoms to study the production of secondary neutrons. The investigated materials were water, Lucite, and tissue-equivalent phantom materials (CIRS Inc., Norfolk, VA). Neutron energy spectra and absorbed dose by neutrons and their secondary particles were scored. In addition, simulations were performed for reference tissues (ICRP/ICRU) to assess tissue equivalence with respect to neutron generation and transport. In order to benchmark the simulation results, measurements were performed with a system developed at the University of Michigan; organic liquid scintillators were used to detect the neutron emissions from the irradiation of tissue-equivalent materials. Additionally, the MPPost code was used to calculate the scintillator response from the MCNPX-PoliMi output. Results: The simulated energy spectra and depth dose curves of the neutrons produced in different phantom materials showed similar shape. The differences of spectra and fluences between all studied materials and reference tissues were well within the achievable precision of neutron dosimetry. The shape of the simulated detector response of the liquid scintillators agreed well with measurements on the proton beamline. Conclusion: Based on Geant4 and MCNPX-PoliMi simulations, the investigated materials appear to be suitable to study the production of neutrons in proton therapy. MC simulations were verified with neutron measurements in therapeutic proton beams. This work was funded in part by the ANDANTE grant of the European Commission in the 7th Framework Program.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-CAMPUS-T-03: Four-Dimensional Dose Distribution Measurement Using Plastic Scintillator

Purpose: To develop the detector for the four-dimensional dose distribution measurement. Methods: We made the prototype detector for four-dimensional dose distribution measurement using a cylindrical plastic scintillator (5 cm diameter) and a conical reflection grass. The plastic scintillator is used as a phantom. When the plastic scintillator is irradiated, the scintillation light was emitted according to absorbed dose distribution. The conical reflection grass was arranged to surround the plastic scintillator, which project to downstream the projection images of the scintillation light. Then, the projection image was reflected to 45 degree direction by flat reflection grass, and was recorded by camcorder. By reconstructing the three-dimensional dose distribution from the projection image recorded in each frame, we could obtain the four-dimensional dose distribution. First, we tested the characteristic according to the amount of emitted light. Then we compared of the light profile and the dose profile calculated with the radiotherapy treatment planning system. Results: The dose dependency of the amount of light showed linearity. The pixel detecting smaller amount of light had high sensitivity than the pixel detecting larger amount of light. However the difference of the sensitivity could be corrected from the amount of light detected in each pixel. Both of the depth light profile through the conical reflection grass and the depth dose profile showed the same attenuation in the region deeper than peak depth. In lateral direction, the difference of the both profiles was shown at outside field and penumbra region. We consider that the difference is occurred due to the scatter of the scintillation light in the plastic scintillator block. Conclusion: It was possible to obtain the amount of light corresponding to the absorbed dose distribution from the prototype detector. Four-dimensional dose distributions can be reconstructed with high accuracy by the correction of the scattered light.

07 ISOTOPE AND RADIATION SOURCES↗

SU-F-BRE-01: A Rapid Method to Determine An Upper Limit On a Radiation Detector's Correction Factor During the QA of IMRT Plans

Purpose: Discrepancies in the verification of the absorbed dose to water from an IMRT plan using a radiation dosimeter can be wither caused by 1) detector specific nonstandard field correction factors as described by the formalism of Alfonso et al. 2) inaccurate delivery of the DQA plan. The aim of this work is to develop a simple/fast method to determine an upper limit on the contribution of composite field correction factors to these discrepancies. Methods: Indices that characterize the non-flatness of the symmetrised collapsed delivery (VSC) of IMRT fields over detector-specific regions of interest were shown to be correlated with IMRT field correction factors. The indices introduced are the uniformity index (UI) and the mean fluctuation index (MF). Each one of these correlation plots have 10 000 fields generated with a stochastic model. A total of eight radiation detectors were investigated in the radial orientation. An upper bound on the correction factors was evaluated by fitting values of high correction factors for a given index value. Results: These fitted curves can be used to compare the performance of radiation dosimeters in composite IMRT fields. Highly water-equivalent dosimeters like the scintillating detector (Exradin W1) and a generic alanine detector have been found to have corrections under 1% over a broad range of field modulations (0 – 0.12 for MF and 0 – 0.5 for UI). Other detectors have been shown to have corrections of a few percent over this range. Finally, a full Monte Carlo simulations of 18 clinical and nonclinical IMRT field showed good agreement with the fitted curve for the A12 ionization chamber. Conclusion: This work proposes a rapid method to evaluate an upper bound on the contribution of correction factors to discrepancies found in the verification of DQA plans.

07 ISOTOPE AND RADIATION SOURCES↗

MO-E-17A-12: Direct Realization of the CT Dose to Phantom: Energy to Heat Conversion in Polyethylene Using Calorimetry

Purpose: To develop a primary reference standard for absorbed dose to phantom for medical CT dosimetry. CT dosimetry relies on the implementation of the CTDI standard based on air kerma. We are taking a step toward an absorbed dose to water standard by first investigating the dose in a solid phantom. By directly measuring the heat converted from the incident radiation, the absorbed dose in the phantom at a point can be assessed with primary methods without relying on indirect conversions. Methods: The calorimeter contains two small thermistors embedded in a removable PE “core” inserted into the cylindrical HDPE phantom. A core made with polystyrene (PS) was also tested because of its purportedly negligible heat defect. Measurements were made using the two cores and with a calibrated ionization chamber in a CT beam. The air chamber values were converted to the dose to medium using appropriate stopping-power ratios from the literature, and then compared to the thermal data. Results: The PS core data yielded a dose of 1.3 times (4-run average, 3% std. dev.) higher than the converted chamber value, whereas the PE core data were inexplicably higher. The possible systematic errors include 1) excess heat from the thermistors, 2) in PE the exothermic chemical reactions, 3) uncertainties of the specific heat capacities of the materials, 4) thermal drift, and 5) theoretical conversion of chamber values. Monte Carlo simulations and finite element heat transfer calculations were performed to address some of these issues. The general validity was assessed in a 6 MV photon beam with an entirely different calibration scheme. Conclusion: This study demonstrates the feasibility but also revealed the difficulty in developing a new primary reference standard for absorbed dose to material for CT. Additional experimental and theoretical work is planned to achieve our goal.

07 ISOTOPE AND RADIATION SOURCES↗

Ion chamber absorbed dose calibration coefficients, N{sub D,w}, measured at ADCLs: Distribution analysis and stability

Purpose: To analyze absorbed dose calibration coefficients, N{sub D,w}, measured at accredited dosimetry calibration laboratories (ADCLs) for client ionization chambers to study (i) variability among N{sub D,w} coefficients for chambers of the same type calibrated at each ADCL to investigate ion chamber volume fluctuations and chamber manufacturing tolerances; (ii) equivalency of ion chamber calibration coefficients measured at different ADCLs by intercomparing N{sub D,w} coefficients for chambers of the same type; and (iii) the long-term stability of N{sub D,w} coefficients for different chamber types by investigating repeated chamber calibrations. Methods: Large samples of N{sub D,w} coefficients for several chamber types measured over the time period between 1998 and 2014 were obtained from the three ADCLs operating in the United States. These are analyzed using various graphical and numerical statistical tests for the four chamber types with the largest samples of calibration coefficients to investigate (i) and (ii) above. Ratios of calibration coefficients for the same chamber, typically obtained two years apart, are calculated to investigate (iii) above and chambers with standard deviations of old/new ratios less than 0.3% meet stability requirements for accurate reference dosimetry recommended in dosimetry protocols. Results: It is found that N{sub D,w} coefficients for a given chamber type compared among different ADCLs may arise from differing probability distributions potentially due to slight differences in calibration procedures and/or the transfer of the primary standard. However, average N{sub D,w} coefficients from different ADCLs for given chamber types are very close with percent differences generally less than 0.2% for Farmer-type chambers and are well within reported uncertainties. Conclusions: The close agreement among calibrations performed at different ADCLs reaffirms the Calibration Laboratory Accreditation Subcommittee process of ensuring ADCL conformance with National Institute of Standards and Technology standards. This study shows that N{sub D,w} coefficients measured at different ADCLs are statistically equivalent, especially considering reasonable uncertainties. This analysis of N{sub D,w} coefficients also allows identification of chamber types that can be considered stable enough for accurate reference dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-136: Assessment of Seasonal Linear Accelerator Output Variations and Associated Impacts

Purpose: Application of process control theory in quality assurance programs promises to allow earlier identification of problems and potentially better quality in delivery than traditional paradigms based primarily on tolerances and action levels. The purpose of this project was to characterize underlying seasonal variations in linear accelerator output that can be used to improve performance or trigger preemptive maintenance. Methods: Review of runtime plots of daily (6 MV) output data acquired using in house ion chamber based devices over three years and for fifteen linear accelerators of varying make and model were evaluated. Shifts in output due to known interventions with the machines were subtracted from the data to model an uncorrected scenario for each linear accelerator. Observable linear trends were also removed from the data prior to evaluation of periodic variations. Results: Runtime plots of output revealed sinusoidal, seasonal variations that were consistent across all units, irrespective of manufacturer, model or age of machine. The average amplitude of the variation was on the order of 1%. Peak and minimum variations were found to correspond to early April and September, respectively. Approximately 48% of output adjustments made over the period examined were potentially avoidable if baseline levels had corresponded to the mean output, rather than to points near a peak or valley. Linear trends were observed for three of the fifteen units, with annual increases in output ranging from 2–3%. Conclusion: Characterization of cyclical seasonal trends allows for better separation of potentially innate accelerator behaviour from other behaviours (e.g. linear trends) that may be better described as true out of control states (i.e. non-stochastic deviations from otherwise expected behavior) and could indicate service requirements. Results also pointed to an optimal setpoint for accelerators such that output of machines is maintained within set tolerances and interventions are required less frequently.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-267: Development of the Compact Graphite Calorimetry System for the High Energy Photon Beam

Purpose: Graphite calorimeter systems are used for the absolute photon dosimetry. But many electronics are demanded in order to measure the tiny temperature changes. Minimizing the control system is needed to make a portable graphite calorimeter. Methods: A Domen-type graphite calorimetry system is constructing to measure the absorbed dose of the high energy photon beam. The graphite calorimeter divided into three parts, Core, Jacket, and Shield. In order to measure the temperature rising of the core due to the radiation accurately, the temperatures of the jacket and the shield should be controlled properly. A commercial temperature controller (Model 350, Lake Shore Cryogenics) was used to minimize the size of control system for making a portable graphite calorimetry system at the cost of the measurement uncertainty. The PID control of the jacket is conducted by the software (LabView) and Model 350 maintain the temperature of shield. Results: Our design value of the heat deposition power in the core is 0.04 mW for the dose rate of 3 Gy/min where the temperature sensitivity of the graphite is 1.4 mK/Gy. While the residuals of the Steinhart-hart equation fitting for the core thermistor were less than 0.1 mK, the temperature resolution of Model 350 is 1 mK. The temperature of the shield was kept within the 5 mK when the room temperature variation was about 0.5 K. Conclusion: The resolution of Model 350 for the temperature measurement and control is not good enough as the control system for the compact graphite calorimetry system. But The performance of Model 350 is good enough to maintain the temperature of the shield constantly. The Model 350 will be replaced by the AC resistance bridge (Model 372, Lake Shore Cryogenics) for the core temperature measurement and the jacket control.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-468: Implementation of the TG-142 QA Process for Seven Linacs with Enhanced Beam Conformance

Purpose: To develop a TG-142 compliant QA process for 7 Varian TrueBeam linear accelerators (linacs) with enhanced beam conformance and dosimetrically matched beam models. To ensure consistent performance of all 7 linacs, the QA process should include a common set of baseline values for use in routine QA on all linacs. Methods: The TG 142 report provides recommended tests, tolerances and frequencies for quality assurance of medical accelerators. Based on the guidance provided in the report, measurement tests were developed to evaluate each of the applicable parameters listed for daily, monthly and annual QA. These tests were then performed on each of our 7 new linacs as they came on line at our institution. Results: The tolerance values specified in TG-142 for each QA test are either absolute tolerances (i.e. ±2mm) or require a comparison to a baseline value. The results of our QA tests were first used to ensure that all 7 linacs were operating within the suggested tolerance values provided in TG −142 for those tests with absolute tolerances and that the performance of the linacs was adequately matched. The QA test results were then used to develop a set of common baseline values for those QA tests that require comparison to a baseline value at routine monthly and annual QA. The procedures and baseline values were incorporated into a spreadsheets for use in monthly and annual QA. Conclusion: We have developed a set of procedures for daily, monthly and annual QA of our linacs that are consistent with the TG-142 report. A common set of baseline values was developed for routine QA tests. The use of this common set of baseline values for comparison at monthly and annual QA will ensure consistent performance of all 7 linacs.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-540: MCNPX Simulation of Proton Dose Distributions in a Water Phantom

Purpose: In this study, fluence and energy deposition of proton and proton by-products and dose distributions were simulated. Lateral dose distributions were also been discussed to understand the difference between Monte Carlo simulations and pencil beam algorithm. Methods: MCNPX codes were used to build a water phantom by using “repeated structures” technique and the doses and fluences in each cell was recorded by mesh tally. This study includes, proton equilibrium and proton disequilibrium case. For the proton equilibrium case, the doses difference between proton and proton by-products were studied. A 160 MeV proton pencil beam was perpendicularly incident into a 40 × 40 × 50 cm{sup 3} water phantom and the scoring volume was 20 × 20 × 0.2 cm{sup 3}. Energy deposition and fluence were calculated from MCNPX with (1) proton only; and (2) proton and secondary particles. For the proton disequilibrium case, the dose distribution variation using different multiple Coulomb scattering were studied. A 70 MeV proton pencil beam was perpendicularly incident into a 40 × 40 × 10 cm{sup 3} water phantom and two scoring voxel sizes of 0.1 × 0.1 × 0.05 cm{sup 3} and 0.01 × 0.01 × 0.05 cm{sup 3} were used for the depth dose distribution, and 0.01 × 0.01 × 0.05 cm{sup 3} for the lateral profile distribution simulations. Results: In the water phantom, proton fluence and dose in depths beyond the Bragg peak were slightly perturbed by the choice of the simulated particle types. The dose from secondary particles was about three orders smaller, but its simulation consumed significant computing time. The depth dose distributions and lateral dose distributions of 70 MeV proton pencil beam obtained from MCNPX, GEANT4, and the pencil beam algorithm showed the significant deviations, probably caused by multiple Coulomb scattering. Conclusion: Multiple Coulomb scattering is critical when there is in proton disequilibrium.

07 ISOTOPE AND RADIATION SOURCES↗