SEARCH · Engineering Papers
Results for “RADIATION DETECTOR”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Array detector for high energy laser based on diffuse transmission sampling
In order to improve the ability and accuracy of measuring the temporal–spatial distribution of the intensity of a large-size, high-energy laser beam, a novel array detecting method based on diffuse transmission sampling is proposed. The measurement principle and the design of the sampling and attenuating unit are presented. High-temperature-resistant diffuse transmission material is used to sample and attenuate a high energy laser beam. Pure copper, whose surface is first sand-blasted and then gold-plated, is applied to scatter the incident high-energy laser beam. The formula for the attenuation ratio was derived in detail. We developed two large-aperture array detectors with spatial resolution of 5 mm, spatial duty ratio of 20%, and useable angle range of ±30° without varying the responsivity, the non-uniformity in the laser profile measurement is below 1%, and the repeatability error in the laser power measurement is approximately 1%. The maximal energy density that the array detector can endure is more than 10 kJ/cm{sup 2}.
Status of the endcap BGO calorimeter of the CMD-3 detector
The electromagnetic endcap BGO calorimeter of the CMD-3 detector is ready for experiments at the new e{sup +}e{sup -} collider VEPP-2000. Light readout is performed by silicon photodiodes. A thermalcontrol system that is able to maintain the calorimeter temperature at a level of 12 {+-}1 deg. C was designed and manufactured. All blocks of the endcap calorimeter are assembled, tested, and prepared for installing at the detector.
: Small Animal SPECT/CT System Based on Position-Sensitive Semiconductor Detectors
We developed a SPECT/CT system for small-animal imaging utilizing a mechanically cooled, position-sensitive germanium detector for the SPECT camera. The detector offers better energy resolution than any other detector previously used for SPECT and demonstrates dual-isotope imaging capabilities superior to that of current commercial small-animal SPECT systems. We also explored a unique SPECT camera configuration consisting of a silicon detector and germanium detector stacked one behind the other and located behind a multi-pinhole collimator. This scheme is intended for imaging iodine-123 radiotracer distributions, with the ~30 keV x-ray emissions detected in the silicon detector and the 159 keV gamma-ray emissions passing through the silicon and detected in the germanium detector. Image reconstruction methods for combining this multi-energy, multi-magnification data were developed and it was shown that inclusion of the silicon data reduced artifacts in comparison to the germanium data alone.
A Revised Look at Relativistic Electrons in the Earth's Inner Radiation Zone and Slot Region
We describe a new, more accurate procedure for estimating and removing inner zone background contamination from Van Allen Probes Magnetic Electron Ion Spectrometer (MagEIS) radiation belt measurements. This new procedure is based on the underlying assumption that the primary source of background contamination in the electron measurements at L shells less than three, energetic inner belt protons, is relatively stable. Since a magnetic spectrometer can readily distinguish between foreground electrons and background signals, we are able to exploit the proton stability to construct a model of the background contamination in each MagEIS detector by only considering times when the measurements are known to be background dominated. We demonstrate, for relativistic electron measurements in the inner zone, that the new technique is a significant improvement upon the routine background corrections that are used in the standard MagEIS data processing, which can “overcorrect” and therefore remove real (but small) electron fluxes. As an example, we show that the previously reported 1-MeV injection into the inner zone that occurred in June of 2015 was distributed more broadly in L and persisted in the inner zone longer than suggested by previous estimates. Such differences can have important implications for both scientific studies and spacecraft engineering applications that make use of MagEIS electron data in the inner zone at relativistic energies. We compare these new results with prior work and present more recent observations that also show a 1-MeV electron injection into the inner zone following the September 2017 interplanetary shock passage.
Liquid Scintillation Detectors for High Energy Neutrinos
Large open volume (not segmented) liquid scintillation detectors have been generally dedicated to low energy neutrino measurements, in the MeV energy region. We describe the potential employment of large detectors (>1 kiloton) for studies of higher energy neutrino interactions, such as cosmic rays and long-baseline experiments. When considering the physics potential of new large instruments the possibility of doing useful measurements with higher energy neutrino interactions has been overlooked. Here we take into account Fermat's principle, which states that the first light to reach each PMT will follow the shortest path between that PMT and the point of origin. We describe the geometry of this process, and the resulting wavefront, which we are calling the 'Fermat surface', and discuss methods of using this surface to extract directional track information and particle identification. This capability may be demonstrated in the new long-baseline neutrino beam from Jaeri accelerator to the KamLAND detector in Japan. Other exciting applications include the use of Hanohano as a movable long-baseline detector in this same beam, and LENA in Europe for future long-baseline neutrino beams from CERN. Also, this methodology opens up the question as to whether a large liquid scintillator detector should be given consideration for use in a future long-baseline experiment from Fermilab to the DUSEL underground laboratory at Homestake.
New observations in the MiniBooNE experiment
The MiniBooNE neutrino oscillation search experiment at Fermilab has recently reported results from a search for microe oscillations, using a data sample corresponding to 5.66 x 1020 protons on target in anti-neutrino mode. The experiment is now se nsitive to the excess of microe events observed by Los Alamos Liquid Scintillator Neutrino Detector (LSND). MiniBooNE data are consistent with microe oscillations in the m2 range of 0.1 to 1.0 eV2 and with the evidence for antineutrino oscillations from L SND.
Forward-backward asymmetry of top quark production at the Tevatron in warped extra dimensional models
The CDF and D0 experiments have reported on the measurement of the forward-backward asymmetry of top quark pair production at the Tevatron and the result is that it is more than 2 standard deviations above the predicted value in the standard model. This has to be added to the long-standing anomaly in the forward-backward asymmetry for bottom quark production at LEP which is 3 standard deviations different from the standard model value. The discrepancy in the bottom asymmetry can be accounted for by the contributions of Kaluza-Klein excitations of electroweak gauge bosons at LEP in warped extra-dimensional models in which the fermions are localized differently along the extra dimension so that the gauge interactions of heavy third generation fermions are naturally different from that of light fermions. In this paper, we show that it is more difficult to elaborate a model generating a significant top asymmetry through exchanges of Kaluza-Klein gluons at the Tevatron due to the indirect constraints originating from precision electroweak data.
One-side forward-backward asymmetry in top quark pair production at the CERN Large Hadron Collider
Both D0 and CDF at Tevatron reported the measurements of forward-backward asymmetry in top pair production, which showed possible deviation from the standard model QCD prediction. In this paper, we explore how to examine the same higher-order QCD effects at the more powerful Large Hadron Collider.
Implications of the Dimuon CP Asymmetry in B{sub d,s} Decays
The D0 Collaboration reported a 3.2{sigma} deviation from the standard model (SM) prediction in the like-sign dimuon asymmetry. Assuming that new physics contributes only to B{sub d,s} mixing, we show that the data can be analyzed without using the theoretical calculation of {Delta}{Gamma}{sub s}, allowing for robust interpretations. We find that this framework gives a good fit to all measurements, including the recent CDF Collaboration S{sub {psi}{phi}} result. The data allow universal new physics with similar contributions relative to the SM in the B{sub d} and B{sub s} systems, but favors a larger deviation in B{sub s} than in B{sub d} mixing. The general minimal flavor violation framework with flavor diagonal CP violating phases can account for the former case and remarkably even for the latter case. This observation makes it simpler to speculate about which extensions with general flavor structure may also fit the data.
Measurement of the Mass Difference between t and t Quarks
We present a direct measurement of the mass difference between t and t quarks using tt candidate events in the lepton+jets channel, collected with the CDF II detector at Fermilab's 1.96 TeV Tevatron pp Collider. We make an event by event estimate of the mass difference to construct templates for top quark pair signal events and background events. The resulting mass difference distribution of data is compared to templates of signals and background using a maximum likelihood fit. From a sample corresponding to an integrated luminosity of 5.6 fb{sup -1}, we measure a mass difference, {Delta}M{sub top}=M{sub t}-M{sub t}=-3.3{+-}1.4(stat){+-}1.0(syst) GeV/c{sup 2}, approximately 2 standard deviations away from the CPT hypothesis of zero mass difference.
Nuclear Physics with MINERvA
MINERvA is a precision neutrino experiment designed to improve our understanding of the neutrino-nucleus interaction. The experiment uses a fully active scintillation detector to allow full event reconstruction and includes nuclear targets helium, water, carbon, iron and lead. Here we describe the first steps in measuring lead to iron to carbon cross section ratios.
Te Inclusions in CZT Detectors: New Method for Correcting Their Adverse Effects
Both Te inclusions and point defects can trap the charge carriers generated by ionizing particles in CdZnTe (CZT) detectors. The amount of charge trapped by point defects is proportional to the carriers’ drift time and can be corrected electronically. In the case of Te inclusions, the charge loss depends upon their random locations with respect to the electron cloud. Consequently, inclusions introduce fluctuations in the charge signals, which cannot be easily corrected. In this paper, we describe direct measurements of the cumulative effect of Te inclusions and its influence on the response of CZT detectors of different thicknesses and different sizes and concentrations of Te inclusions. We also discuss a means of partially correcting their adverse effects.
Studying of B{sub s{yields}}K{sup (* )-{pi}+}, K{sup (*)-{rho}+} decays within supersymmetry
Recent results from the CDF Collaboration favor a large CP asymmetry in B{sub s{yields}}K{sup -{pi}+} decay, while the standard model prediction is very small. Moreover, the measurement of its branching ratio is lower than the standard model prediction based on the QCD factorization. We compute the gluino-mediated supersymmetry contributions to B{sub s{yields}}K{sup (*)-{pi}+}, K{sup (*)-{rho}+} decays in the framework of the mass insertion method, and find that for (m{sub g}-tilde){sup 2}/m{sub q}-tilde{sup 2}){<=}2, the theoretical predictions including the LR and RL mass insertion contributions are compatible with the measurements of B{sub s{yields}}K{sup -{pi}+} decay and B{sup 0}-B{sup 0} mixing within 2{sigma} ranges. Using the constrained LR and RL mass insertion parameter spaces, we explore the supersymmetry mass insertion effects on the branching ratios, the direct CP asymmetries, and the polarization fractions in B{sub s{yields}}K*{sup -{pi}+}, K{sup -{rho}+}, K*{sup -{rho}+} decays. We find the constrained LR and RL insertions can provide sizable contributions to the branching ratios of B{sub s{yields}}K*{sup -{pi}+}, K{sup (*)-{rho}+} as well as the direct CP asymmetry and the longitudinal polarization of B{sub s{yields}}K*{sup -{rho}+} decay without conflict with all related data within 2{sigma} ranges. Near future experiments at Fermi Lab and CERN LHC-b can test our predictions and shrink/reveal the mass insertion parameter spaces.
Search for a Fermiophobic Higgs Boson Decaying into Diphotons in pp Collisions at sq root(s)=1.96 TeV
A search for a narrow diphoton mass resonance is presented based on data from 3.0 fb{sup -1} of integrated luminosity from pp collisions at sq root(s)=1.96 TeV collected by the CDF experiment. No evidence of a resonance in the diphoton mass spectrum is observed, and upper limits are set on the cross section times branching fraction of the resonant state as a function of Higgs boson mass. The resulting limits exclude Higgs bosons with masses below 106 GeV/c{sup 2} at a 95% Bayesian credibility level for one fermiophobic benchmark model.
Validation of neutron-induced reactions on natural carbon using an active target at neutron energies up to 22 MeV at LANSCE
A single crystal chemical vapor deposited (sCVD) diamond detector is used as an active target to measure neutron-induced reactions on natural carbon using the neutrons produced by spallation, with a broad energy spectrum at LANSCE. Additionally, the neutron-induced reactions are detected in the diamond as low as E n = 400 keV and up to approximately 100 MeV. Relative cross sections for C 12 ( n , α 0 ) , C 12 ( n , p 0 ) , C 12 ( n , d 0 + p 1 ) , and C 13 ( n , α 0 ) are reported up to E n = 22 MeV and comparisons on detected pulse-height spectra and detector response of scattering reactions are made with GEANT4 simulations using the ENDF/B-VIII.0 evaluated nuclear data library up to 20 MeV. The results are compared with past experimental data, including other works that incorporate diamond detectors as an active carbon target. In addition, R-matrix calculations for the C 13 + n system are presented.
Experimental Searches for Higgs Bosons at the Tevatron
With an integrated luminosity of more than 6 fb{sup -1}, the Tevatron collider with its two general-purpose experiments CDF and DOe offers unique possibilities to constrain and search for Higgs bosons within and beyond the Standard Model. This review summarizes current results from a large number of search channels and their statistical combination, which is then interpreted in terms of new limits on Higgs production in the Standard Model as well as the Minimal Supersymmetric Standard Model.
Optimization of the Two-Baseline Beta Beam
We propose a beta-Beam experiment with four source ions and two baselines for the best possible sensitivity to theta{sub 13}, CP violation and mass hierarchy. Neutrinos from {sup 18}Ne and {sup 6}He with Lorentz boost gamma 350 are detected in a 500 kton water Cerenkov detector at a distance L = 650 km from the source. Neutrinos from {sup 8}B and {sup 8}Li are detected in a 50 kton magnetized iron detector at a distance L = 7000 km from the source. Since a tilt angle theta = 34.5 deg. is required to send the beam to the magic baseline, the far end of the ring has a maximum depth of d = 2132 m. We alleviate this problem by proposing to trade reduction of the decay ring with the increase in the boost factor of the {sup 8}Li and {sup 8}B ions up to gamma8{sub Li} = 390 and gamma8{sub Li} = 650, such that the number of events at the detector remains almost the same. We study the sensitivity reach of this two-baseline two-storage ring beta-Beam experiment, and compare it with the corresponding reach of the other proposed facilities.