Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

A Kinematic, Flexure-based Mechanism for Precise, Parallel Motion for the Hertz Variable-delay Polarization Modulator (VPM)

We describe the design of the linear motion stage for a Variable-delay Polarization Modulator (VPM) and of a grid flattener that has been built and integrated into the Hertz ground-based, submillimeter polarimeter. VPMs allow the modulation of a polarized source by controlling the phase difference between two linear, orthogonal polarizations. The size of the gap between a mirror and a very flat polarizing grid determines the amount of the phase difference. This gap must be parallel to better than 1% of the wavelength. A novel, kinematic, flexure-based mechanism is described that passively maintains the parallelism of the mirror and the grid to 1.5 pm over a 150 mm diameter, with a 400 pm throw. A single piezoceramic actuator is used to modulate the gap, and a capacitive sensor provides position feedback for closed-loop control. A simple device that ensures the planarity of the polarizing grid is also described. Engineering results from the deployment of this device in the Hertz instrument April 2006 at the Submillimeter Telescope Observatory (SMTO) in Arizona are presented.

Voellmer, G. M.↗

Moon Mineral Mapper (M3): A High Uniformity and High Precision Science Imaging Spectrometer in the Solar Reflected Spectrum

The Moon Mineralogy Mapper was selected as a NASA Discovery Mission of Opportunity in February 2005. At the core of this mission is an imaging spectrometer instrument with high spectral-spatial uniformity and high signal-to-noise ratio for the expected illumination conditions. The spectral range of the Moon Mineralogy Mapper is from 430 to 3000 nm with 10 nm spectral sampling. The radiometric range is from 0 to maximum expected radiance with 14 bit sampling. The spatial swath is nominally 40 Ian with 70 m spatial sampling. The Moon Mineralogy Mapper has both a global and target mode of data acquisition. In global spectral and spatial resolution full coverage of the Moon will be acquired. Target mode will be used to examine selected areas a full spectral and spatial resolution. The science objectives and mission and instrument characteristics are presented.

mapping↗

Precise Orbit Determination for GEOSAT Follow-On Using Satellite Laser Ranging Data and Intermission Altimeter Crossovers

The U.S. Navy's GEOSAT Follow-On Spacecraft was launched on February 10, 1998 and the primary objective of the mission was to map the oceans using a radar altimeter. Following an extensive set of calibration campaigns in 1999 and 2000, the US Navy formally accepted delivery of the satellite on November 29, 2000. The spacecraft is tracked by satellite laser ranging (SLR) and Doppler (Tranet-style) beacons. Although a limited amount of GPS data were obtained, the primary mode of tracking remains satellite laser ranging. In this paper, we report on progress in orbit determination for GFO using GFO/GFO and TOPEX/GFO altimeter crossovers. We have tuned the nonconservative force model for GFO and the gravity model using SLR, Doppler and altimeter crossover data spanning over one year. Preliminary results show that the predicted radial orbit error from the gravity field covariance to 70x70 on GEOSAT was reduced from 2.6 cm in EGM96 to 1.9 cm with the addition of only five months of the GFO SLR and GFO/GFO crossover data. Further progress is possible with the addition of more data, particularly the TOPEX/GFO crossovers. We will evaluate the tuned GFO gravity model (a derivative of EGM96) using altimeter data from the GEOSAT mission. In January 2000, a limited quantity of GPS data were obtained. We will use these GPS data in conjunction with the SLR and altimeter crossover data obtained over the same time span to compute quasi-reduced dynamic orbits which will also aid in the evaluation of the tuned GFO geopotential model.

Lemoine, F. G.↗

Alignment Jig for the Precise Measurement of THz Radiation

A miniaturized instrumentation package comprising a (1) Global Positioning System (GPS) receiver, (2) an inertial measurement unit (IMU) consisting largely of surface-micromachined sensors of the microelectromechanical systems (MEMS) type, and (3) a microprocessor, all residing on a single circuit board, is part of the navigation system of a compact robotic spacecraft intended to be released from a larger spacecraft [e.g., the International Space Station (ISS)] for exterior visual inspection of the larger spacecraft. Variants of the package may also be useful in terrestrial collision-detection and -avoidance applications. The navigation solution obtained by integrating the IMU outputs is fed back to a correlator in the GPS receiver to aid in tracking GPS signals. The raw GPS and IMU data are blended in a Kalman filter to obtain an optimal navigation solution, which can be supplemented by range and velocity data obtained by use of (l) a stereoscopic pair of electronic cameras aboard the robotic spacecraft and/or (2) a laser dynamic range imager aboard the ISS. The novelty of the package lies mostly in those aspects of the design of the MEMS IMU that pertain to controlling mechanical resonances and stabilizing scale factors and biases.

Javadi, Hamid H.↗

Precision Cleaning of Oxygen Systems and Components

Currently, NASA uses Dichloropentafluoropropane (HCFC-225), a Class II ozone depleting substance (ODs), to clean contaminated oxygen systems. Starting in 20 15, the Montreal Protocols and Clean Air Act prohibit the production and importation of all hydrochlorofluorocarbons (HCFC), except for limited use in refrigeration applications. Thus, a new non-ozone depleting solvent needs to be developed for use in cleaning. Optimally, such a solvent should also be environmentally benign or green to avoid needing to replace the new solvent with yet another solvent in the future due to other environmental concerns. Work for the first year consisted of two parts. The first part was developing a method of testing the cleaning efficiency of potential solvents. Stainless steel coupons were contaminated with a known weight of various contaminants and contaminant combinations and then immersed in solvent for ten minutes. The coupons were then removed and dried in an oven until all solvent had evaporated. Once dry, the coupons were weighed and the mass of the non-volatile residue (NVR) left on the coupon was determined. The cleaning efficiency of the solvents is reported as percent cleaning, with 100% cleaning being zero NVR left on the test coupon. The second half of the first goal was to use the develop method to perform baseline testing on current solvents. The second part of the work was to begin exploring alternative cleaning solvents. A variety of hydrofluorocarbons (HFCs) were tested. Preliminary testing was also performed with ionic liquids and aqueous surfactant solutions. Once potential solvents were identified, an analysis of the performance and environmental characteristics of each was to be conducted. Four contaminants were specified for use in testing. These are Mil-Spec-H-5606 (5606), a hydraulic fluid, Mil-H-83282B (83282), another hydraulic fluid, diethylhexyl sebacate (Sebacate), and WD-40. The structures of these contaminants are all similar, with long aliphatic hydrocarbon chains of lengths between fifteen and fifty. Contaminants were tested both individually and in combination. All combinations were done with equal weights of the constituent contaminants.

McLaughlin, Russell↗

Precision Measurement of Complete Black Hole Binary Inspiral-Merger-Ringdown Signals with LISA

Until recently, only the inspiral and ringdown phases of black hole binary (131-113) coalescences had been modeled. The merger signals, which were expected to be the most luminous portion of the total signal, were unavailable due to the technical difficulty of calculating the behavior of a BHB in this highly dynamical and non-linear regime. Advancements in the field of numerical relativity make it possible to include the merger segment of 131113 coalescence in the search for and characterization of gravitational wave signals. The implications for LISA include an increase in the event rate due to the increase in achievable signal-to-noise ratio, as well as potentially improved accuracy regarding the extraction of the source parameters. We investigate the degree to which mergers improve parameter estimation, by studying the impact of including mergers on achievable parameter accuracy over a significant range of masses and mass ratios for nonspinning systems, and its impact on LISA science.

McWilliams, Sean T.↗

Time-Separating Heating and Sensor Functions of Thermistors in Precision Thermal Control Applications

A method allows combining the functions of a heater and a thermometer in a single device, a thermistor, with minimal temperature read errors. Because thermistors typically have a much smaller thermal mass than the objects they monitor, the thermal time to equilibrate the thermometer to the temperature of the object is typically much shorter than the thermal time of the object to change its temperature in response to an external perturbation.

Cho, Hyung J.↗

Continued Development of a Precision Cryogenic Dilatometer for the James Webb Space Telescope

As part of the James Webb Space Telescope (JWST) materials working group, a novel cryogenic dilatometer was designed and built at NASA Jet Propulsion Laboratory to help address stringent coefficient of thermal expansion (CTE) knowledge requirements. Previously reported results and error analysis have estimated a CTE measurement accuracy for ULE of 1.7 ppb/K with a 20K thermal load and 0.1 ppb/K with a 280K thermal load. Presented here is a further discussion of the cryogenic dilatometer system and a description of recent work including system modifications and investigations.

thermal strain↗

Mars-GRAM: Increasing the Precision of Sensitivity Studies at Large Optical Depths

The Mars Global Reference Atmospheric Model (Mars-GRAM) is an engineering-level atmospheric model widely used for diverse mission applications. Mars-GRAM's perturbation modeling capability is commonly used, in a Monte-Carlo mode, to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). It has been discovered during the Mars Science Laboratory (MSL) site selection process that Mars-GRAM, when used for sensitivity studies for MapYear=0 and large optical depth values such as tau=3, is less than realistic. A comparison study between Mars atmospheric density estimates from Mars-GRAM and measurements by Mars Global Surveyor (MGS) has been undertaken for locations of varying latitudes, Ls, and LTST on Mars. The preliminary results from this study have validated the Thermal Emission Spectrometer (TES) limb data. From the surface to 80 km altitude, Mars-GRAM is based on the NASA Ames Mars General Circulation Model (MGCM). MGCM results that were used for Mars-GRAM with MapYear=0 were from a MGCM run with a fixed value of tau=3 for the entire year at all locations. This has resulted in an imprecise atmospheric density at all altitudes. To solve this pressure-density problem, density factor values were determined for tau=.3, 1 and 3 that will adjust the input values of MGCM MapYear 0 pressure and density to achieve a better match of Mars-GRAM MapYear 0 with TES observations for MapYears 1 and 2 at comparable dust loading. The addition of these density factors to Mars-GRAM will improve the results of the sensitivity studies done for large optical depths.

Justh, Hilary L.↗

High-Precision Pulse Generator

A document discusses a pulse generator with subnanosecond resolution implemented with a low-cost field-programmable gate array (FPGA) at low power levels. The method used exploits the fast carry chains of certain FPGAs. Prototypes have been built and tested in both Actel AX and Xilinx Virtex 4 technologies. In-flight calibration or control can be performed by using a similar and related technique as a time interval measurement circuit by measuring a period of the stable oscillator, as the delays through the fast carry chains will vary as a result of manufacturing variances as well as the result of environmental conditions (voltage, aging, temperature, and radiation).

Katz, Richard↗

Simplified Architecture for Precise Aiming of a Deep-Space Communication Laser Transceiver

The simplified architecture is a minimal system for a deep-space optical communications transceiver. For a deepspace optical communications link the simplest form of the transceiver requires (1) an efficient modulated optical source, (2) a point-ahead mechanism (PAM) to compensate for two-way light travel, (3) an aperture to reduce the divergence of the transmit laser communication signal and also to collect the uplink communication signal, and (4) a receive detector to sense the uplink communication signal. Additional components are introduced to mitigate for spacecraft microvibrations and to improve the pointing accuracy. The Canonical Transceiver implements this simplified architecture (see figure). A single photon-counting smart focal plane sensor combines acquisition, tracking, and forward link data detection functionality. This improves optical efficiency by eliminating channel splits. A transmit laser blind sensor (e.g. silicon with 1,550-nm beam) provides transmit beam-pointing feedback via the two-photon absorption (TPA) process. This vastly improves the transmit/receive isolation because only the focused transmit beam is detected. A piezoelectric tiptilt actuator implements the required point-ahead angle. This point-ahead mechanism has been demonstrated to have near zero quiescent power and is flight qualified. This architecture also uses an innovative 100-mHz resonant frequency passive isolation platform to filter spacecraft vibrations with voice coil actuators for active tip-tilt correction below the resonant frequency. The canonical deep-space optical communications transceiver makes synergistic use of innovative technologies to reduce size, weight, power, and cost. This optical transceiver can be used to retire risks associated with deep-space optical communications on a planetary pathfinder mission and is complementary to ongoing lunar and access link developments.

Ortiz, Gerard G.↗

Simultaneous Noncontact Precision Imaging of Microstructural and Thickness Variation in Dielectric Materials Using Terahertz Energy

A process for simultaneously measuring the velocity of terahertz electromagnetic radiation in a dielectric material sample without prior knowledge of the thickness of the sample and for measuring the thickness of a material sample using terahertz electromagnetic radiation in a material sample without prior knowledge of the velocity of the terahertz electromagnetic radiation in the sample is disclosed and claimed. The process evaluates, in a plurality of locations, the sample for microstructural variations and for thickness variations and maps the microstructural and thickness variations by location. A thin sheet of dielectric material may be used on top of the sample to create a dielectric mismatch. The approximate focal point of the radiation source (transceiver) is initially determined for good measurements.

Roth, Donald J↗

A Hollow-Waveguide Gas Correlation Radiometer for Ultra-Precise Column Measurements of Formaldehyde on Mars

We present preliminary results in the development of a miniaturized gas correlation radiometer that implements a hollow-core optical fiber (hollow waveguide) gas correlation cell. The substantial reduction in mass and volume of the gas correlation cell makes this technology appropriate for an orbital mission -- capable of pinpointing sources of trace gases in the Martian atmosphere. Here we demonstrate a formaldehyde (H2CO) sensor and report a detection limit equivalent to approximately 30 ppb in the Martian atmosphere. The relative simplicity of the technique allows it to be expanded to measure a range of atmospheric trace gases of interest on Mars such as methane (CH4), water vapour (H2O), deuterated water vapour (HDO), and methanol (CH3OH). Performance of a formaldehyde instrument in a Mars orbit has been simulated assuming a 3 meter long, 1000 micron inner diameter hollow-core fiber gas correlation cell, a 92.8 degree sun-synchronous orbit from 400 km with a horizontal sampling scale of 10 km x 10 km. Initial results indicate that for one second of averaging, a detection limit of 1 ppb is possible.

Wilson, Emily L.↗

The New Era of Precision Cosmology: Testing Gravity at Large Scales

Cosmic acceleration may be the biggest phenomenological mystery in cosmology today. Various explanations for its cause have been proposed, including the cosmological constant, dark energy and modified gravities. Structure formation provides a strong test of any cosmic acceleration model because a successful dark energy model must not inhibit the development of observed large-scale structures. Traditional approaches to studies of structure formation in the presence of dark energy ore modified gravity implement the Press & Schechter formalism (PGF). However, does the PGF apply in all cosmologies? The search is on for a better understanding of universality in the PGF In this talk, I explore the potential for universality and talk about what dark matter haloes may be able to tell us about cosmology. I will also discuss the implications of this and new cosmological experiments for better understanding our theory of gravity.

Prescod-Weinstein, Chanda↗

Mars-GRAM 2010: Improving the Precision of Mars-GRAM

It has been discovered during the Mars Science Laboratory (MSL) site selection process that the Mars Global Reference Atmospheric Model (Mars-GRAM) when used for sensitivity studies for Thermal Emission Spectrometer (TES) MapYear=0 and large optical depth values, such as tau=3, is less than realistic. Mars-GRAM's perturbation modeling capability is commonly used, in a Monte-Carlo mode, to perform high fidelity engineering end-to-end simulations for entry, descent, and landing (EDL). Mars-GRAM 2005 has been validated against Radio Science data, and both nadir and limb data from TES. Traditional Mars-GRAM options for representing the mean atmosphere along entry corridors include: (1) TES mapping year 0, with user-controlled dust optical depth and Mars-GRAM data interpolated from NASA Ames Mars General Circulation Model (MGCM) results driven by selected values of globally-uniform dust optical depth, or (2) TES mapping years 1 and 2, with Mars-GRAM data coming from MGCM results driven by observed TES dust optical depth. From the surface to 80 km altitude, Mars-GRAM is based on NASA Ames MGCM. Above 80 km, Mars-GRAM is based on the University of Michigan Mars Thermospheric General Circulation Model (MTGCM). MGCM results that were used for Mars-GRAM with MapYear=0 were from a MGCM run with a fixed value of tau=3 for the entire year at all locations. This choice of data has led to discrepancies that have become apparent during recent sensitivity studies for MapYear=0 and large optical depths. Unrealistic energy absorption by time-invariant atmospheric dust leads to an unrealistic thermal energy balance on the polar caps. The outcome is an inaccurate cycle of condensation/sublimation of the polar caps and, as a consequence, an inaccurate cycle of total atmospheric mass and global-average surface pressure. Under an assumption of unchanged temperature profile and hydrostatic equilibrium, a given percentage change in surface pressure would produce a corresponding percentage change in density at all altitudes. Consequently, the final result of a change in surface pressure is an imprecise atmospheric density at all altitudes.

Justh, H. L.↗

Unsteady Aerodynamic Model Tuning for Precise Flutter Prediction

A simple method for an unsteady aerodynamic model tuning is proposed in this study. This method is based on the direct modification of the aerodynamic influence coefficient matrices. The aerostructures test wing 2 flight-test data is used to demonstrate the proposed model tuning method. The flutter speed margin computed using only the test validated structural dynamic model can be improved using the additional unsteady aerodynamic model tuning, and then the flutter speed margin requirement of 15 % in military specifications can apply towards the test validated aeroelastic model. In this study, unsteady aerodynamic model tunings are performed at two time invariant flight conditions, at Mach numbers of 0.390 and 0.456. When the Mach number for the unsteady model tuning approaches to the measured fluttering Mach number, 0.502, at the flight altitude of 9,837 ft, the estimated flutter speed is approached to the measured flutter speed at this altitude. The minimum flutter speed difference between the estimated and measured flutter speed is -.14 %.

Pak, Chan-Gi↗

Isogrid Membranes for Precise, Singly Curved Reflectors

A new type of composite material has been proposed for membranes that would constitute the reflective surfaces of planned lightweight, single-curvature (e.g., parabolic cylindrical) reflectors for some radar and radio-communication systems. The proposed composite materials would consist of polyimide membranes containing embedded grids of highstrength (e.g., carbon) fibers. The purpose of the fiber reinforcements, as explained in more detail below, is to prevent wrinkling or rippling of the membrane.

Fang, Houfei↗

Precision Laser Development for Gravitational Wave Space Mission

Optical fiber and semiconductor laser technologies have evolved dramatically over the last decade due to the increased demands from optical communications. We are developing a laser (master oscillator) and optical amplifier based on those technologies for interferometric space missions, such as the gravitational-wave mission LISA, and GRACE follow-on, by fully utilizing the mature wave-guided optics technologies. In space, where a simple and reliable system is preferred, the wave-guided components are advantageous over bulk, crystal-based, free-space laser, such as NPRO (Non-planar Ring Oscillator) and bulk-crystal amplifier, which are widely used for sensitive laser applications on the ground.

Numata, Kenji↗