Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Additive Manufacturing of Porous Ceramics With Foaming Agent

The macro-porous ceramics has promising durability and thermal insulation performance. As porous ceramics find more and more applications across many industries, a cost-effective and scalable additive manufacturing technique for fabricating macro-porous ceramics is highly desirable. Herein, we reported a facile additive manufacturing approach to fabricate porous ceramics and control the printed porosity. Several printable ceramic inks were prepared, and the foaming agent was added to generate gaseous bubbles in the ink, followed by the direct ink writing and the ambient-pressure and room-temperature drying to create the three-dimensional geometries. In this work, a set of experimental studies were performed to optimize the printing quality. The results revealed the optimal process parameters for printing the foamed ceramic ink with a high spatial resolution and fine surface quality. Varying the concentration of the foaming agent enables the controllability of the structural porosity. The maximum porosity can reach 85%, with a crack-free internal porous structure. The tensile tests showed that the printed macro-porous ceramics possessed enhanced durability with the addition of fiber. With a high-fidelity three-dimensional (3D) printing process and the precise controllability of the porosity, we showed that the printed samples exhibited a remarkably low thermal conductivity and durable mechanical strength.

36 MATERIALS SCIENCE↗

Consideration of Nonideal Detonation Regimes Influenced by Wave Modes in a Water-Cooled Rotating Detonation Engine Using OH* Chemiluminescence

Although inherently unstable, existing research in rotating detonation combustion supports its application in notionally steady processes resulting in greater availability compared to conventional, constant pressure combustion. Further improvements rely on a more in-depth understanding of system losses and identifying conditions which optimize device performance. Within this study, the presence and proportion of ideal and nonideal combustion regimes are compared across a variety of process conditions and wave modes. Here, large-scale data analysis seeks to summarize proportional heat release associated with commensal, parasitic, and detonative combustion averaged across individual traces of OH* chemiluminescent data acquired at the detonation plane. Means of regime partitioning based on the anatomy of the time-resolved OH* signal are proposed to ensure consistent analysis throughout the current and future studies concerning combustion regimes. Of particular interest is the possible influence of wave on the nonideal combustion in relative proportion to the desired detonation. Results showed improved percent detonation with increasing significance for the following trends: decreasing equivalence ratio, increasing wave count, decreasing wave velocity, and increasing detonation time. Increased wave number, brought on by decreased equivalence ratios and wave velocities, is thought to decrease fill region surface area, and therefore, decrease nonideal contact burning. Additional analysis is performed to consider possible trend variation due to the presence of stable galloping waves, which were found to have minimal influence on relative percent detonation values. The outcome of this study suggests operational states, which correspond to increased wave quantities for increased proportions of reactants consumed by the targeted detonative combustion regime.

42 ENGINEERING↗

Data-Efficient Dimensionality Reduction and Surrogate Modeling of High-Dimensional Stress Fields

Tensor datatypes representing field variables like stress, displacement, velocity, etc., have increasingly become a common occurrence in data-driven modeling and analysis of simulations. Numerous methods [such as convolutional neural networks (CNNs)] exist to address the meta-modeling of field data from simulations. As the complexity of the simulation increases, so does the cost of acquisition, leading to limited data scenarios. Modeling of tensor datatypes under limited data scenarios remains a hindrance for engineering applications. Here, in this article, we introduce a direct image-to-image modeling framework of convolutional autoencoders enhanced by information bottleneck loss function to tackle the tensor data types with limited data. The information bottleneck method penalizes the nuisance information in the latent space while maximizing relevant information making it robust for limited data scenarios. The entire neural network framework is further combined with robust hyperparameter optimization. We perform numerical studies to compare the predictive performance of the proposed method with a dimensionality reduction-based surrogate modeling framework on a representative linear elastic ellipsoidal void problem with uniaxial loading. The data structure focuses on the low-data regime (fewer than 100 data points) and includes the parameterized geometry of the ellipsoidal void as the input and the predicted stress field as the output. The results of the numerical studies show that the information bottleneck approach yields improved overall accuracy and more precise prediction of the extremes of the stress field. Additionally, an in-depth analysis is carried out to elucidate the information compression behavior of the proposed framework.

artificial intelligence↗

Development of a 300 MWe Utility Scale Oxy-Fuel sCO2 Turbine

A 300 MWe direct-fired supercritical carbon dioxide (sCO2) oxy-fuel turbine is being developed that will burn natural gas-fired, coal syngas and even hydrogen mixtures capable of 1,150ºC turbine inlet temperature at 300 bar. This design will significantly improve the state-of-the-art for thermal efficiency and results in a high-pressure stream of CO2 with 98%+ carbon capture, making the power plant near emission-free and more efficient than Natural Gas Combined Cycle (NGCC) plants with carbon capture. This power plant will be capable of burning coal through gasification and cleanup of the synthesis gas (syngas). sCO2 power cycles are a transformational technology for the energy industry, providing higher efficiency heat source energy conversion for conventional and alternative energy sources. This novel cycle significantly reduces capital costs because of smaller equipment footprints, design modularity, and allows for rapid cyclic load and source following to balance solar and wind energy power swings. Oxy-fuel sCO2 cycles take these advantages even further, utilizing higher firing temperatures, improved efficiency, and simpler carbon capture strategies. This turbine will require cooled turbine nozzles and blades as well as advanced thermal management systems to accommodate these high temperatures. The cooled blade heat transfer correlations required new test programs at higher Reynolds number than air-breathing gas turbines for impingement, serpentine, and pin-fin regions. Novel blade optimization was performed to maximize aerodynamic efficiency, while minimizing cooling flows. A turbine layout was generated utilizing individual combustor cans with cooled liners feeding into a 6-stage axial flow turbine with cooled stator nozzles and turbine blades. The case design and thermal management preliminary design will be described.

Moore, Jeffrey↗

Year 2 instrument status from the SPT-3G cosmic microwave background receiver (Conference Presentation)

The South Pole Telescope (SPT) is a millimeter-wavelength telescope surveying the cosmic microwave background (CMB). The SPT measures both the temperature and polarization of the CMB with a large aperture, resulting in high-resolution maps sensitive to signals across a wide range of angular scales on the sky. With these capabilities, the SPT has the potential to constrain inflationary gravitational waves as well as the effect of massive neutrinos on large-scale structure formation. The SPT was upgraded in late 2016 with a new receiver (SPT-3G) containing 16,0000 polarization-sensitive transition-edge sensor bolometers. Several key technological developments have enabled this large-format focal, including advances in detectors, readout electronics, and large millimeter-wavelength optics. We will discuss the implementation of these technologies in the SPT-3G receiver as well as the challenges they presented. In late 2017 the implementations of all three of these technologies were iterated to optimize total performance. Here, we present the current instrument status of the SPT-3G receiver.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Transfer of autocollimator calibration for use with scanning gantry profilometers for accurate determination of surface slope and curvature of state-of-the-art x-ray mirrors

X-ray optics, desired for beamlines at free-electron-laser and diffraction-limited-storage-ring x-ray light sources, must have almost perfect surfaces, capable of delivering light to experiments without significant degradation of brightness and coherence. To accurately characterize such optics at an optical metrology lab, two basic types of surface slope profilometers are used: The long trace profilers (LTPs) and nanometer optical measuring (NOM) like angular deflectometers, based on electronic autocollimator (AC) ELCOMAT-3000. The inherent systematic errors of the instrument's optical sensors set the principle limit to their measuring performance. Where autocollimator of a NOM-like profiler may be calibrated at a unique dedicated facility, this is for a particular configuration of distance, aperture size, and angular range that does not always match the exact use in a scanning measurement with the profiler. Here we discuss the developed methodology, experimental set-up, and numerical methods of transferring the calibration of one reference AC to the scanning AC of the Optical Surface Measuring System (OSMS), recently brought to operation at the ALS Xray Optics Laboratory. We show that precision calibration of the OSMS performed in three steps, allows us to provide high confidence and accuracy low-spatial-frequency metrology and not â€print into' measurements the inherent systematic error of tool in use. Here, with the examples of the OSMS measurements with a state-of-The-Art x-ray aspherical mirror, available from one of the most advanced vendors of X-ray optics, we demonstrate the high efficacy of the developed calibration procedure. The results of our work are important for obtaining high reliability data, needed for sophisticated numerical simulations of beamline performance and optimization of beamline usage of the optics. This work was supported by the U. S. Department of Energy under contract number DE-AC02-05CH11231.

47 OTHER INSTRUMENTATION↗

SU-E-T-410: Fringe Stability and Phase Shift Measurements in a Michelson Interferometer for Optical Calorimetry

Purpose: To identify the variables limiting the resolution of a Michelson interferometer used to measure phase shifts (PS) in water as part of a radiometric calorimeter. Methods: We investigated the output stability of a He-Ne laser and a laser diode. The short and long term stability of the fringe pattern in a Michelson interferometer was tested with different types of lasers, thermal insulation arrangements, damping systems and optical mounts to optimize system performance. PS were induced by electrically heating water in a 1 cm quartz cuvette located in one of the interferometer arms. The PS was calculated from fringe intensity changes and compared to a calculated PS using thermocouple-measured temperature changes in the water. Results: The intensity of the laser diode is more stable, but the gas laser’s profile is more suitable for fringe analysis and has better temporal coherence. The laser requires a warm-up time of 4 hours before its output is stabilized (SNR>95). The fringe’s stability strongly depends on the thermal insulation. When the interferometer is exposed to ambient temperature swings of 0.7 K, it is not possible to stabilize the fringe pattern. Enclosing the system in a 2.5 cm-thick Styrofoam box improves the SNR, but further insulation will be needed to increase the SNR above 50. High frequency noise is significantly reduced by damping the system.Inducing a temperature rise in water, starting at 299 K, the average temperature increase for a 2π PS is 0.29 ± 0.02 K and the proportionality constant is -21.1 ± 0.8 radians/K. This is 5.8% lower than the calculated value using the thermocouple. Conclusion: Interferometric PS measurements of temperature may provide an alternative to thermistors for water calorimetry. The resolution of the current prototype is limited by ambient temperature stability. Calculated and measured thermally-induced PS in water agreed to within 5.8%.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

TH-A-BRF-03: Evaluation of Synthetic CTs Generated Using MR-SIM Data

Purpose: To describe and evaluate a novel algorithm for generating synthetic CT images from MR-SIM data for dose calculations in MR-only treatment planning. Methods: A voxel-based weighted summation method was implemented to generate synthetic CT (synCT) images. MR data were acquired using Philips 1.0T Panorama high-field open MR-SIM. Retrospective patient data from seven prostate patients and one brain patient (three lesions) enrolled in an IRB-approved study were used. 3D T1-weighted fast field echo and 3D T2-weighted turbo spin echo sequences were utilized for all patients. A 3D balanced turbo field echo sequence using spectral presaturation with inversion recovery was acquired for prostate patients, but 3D ultra-short echo time (UTE)-DIXON was instead acquired for the brain patient to amplify bone signal for semi-automatic bone segmentation. Weight optimization was performed using a training subset of patients. HU value differences between planning CT and synCTs were analyzed using mean absolute error (MAE). Original patient CT-based treatment plans were mapped onto synCTs, dose was recalculated using original leaf motion and MU values, and DRRs were generated. Dosevolume metrics and gamma analysis were used for dosimetric evaluation. Results: Average whole-body MAE of synCTs across all patients was 75+12 HU. In prostate cancer patients, average HU difference between planning and synCTs was 0.9±1.0% for soft tissue structures and 4.3±2.5% for bony structures. DRRs were generated from synCTs and qualitatively showed good geometric agreement with planning CT-generated DRRs. D99, mean dose, and maximum dose to CTV calculated using the synCT remained within 1.2% of planning CT-based dose calculations. All gamma analysis evaluated at 2%/2mm dose difference/distance to agreement) pass rates were greater than 95% with an average of 99.9±0.1% for prostate patients and 98.4±2.2% for three brain lesions. Conclusion: SynCTs were generated with clinically acceptable accuracy comparable to planning CTs, enabling dose computations for MR-only simulation. Research supported in part by a grant from Philips HealthCare (Best, Netherlands)

60 APPLIED LIFE SCIENCES↗

Maximizing the probability of satisfying the clinical goals in radiation therapy treatment planning under setup uncertainty

Purpose: This paper introduces a method that maximizes the probability of satisfying the clinical goals in intensity-modulated radiation therapy treatments subject to setup uncertainty. Methods: The authors perform robust optimization in which the clinical goals are constrained to be satisfied whenever the setup error falls within an uncertainty set. The shape of the uncertainty set is included as a variable in the optimization. The goal of the optimization is to modify the shape of the uncertainty set in order to maximize the probability that the setup error will fall within the modified set. Because the constraints enforce the clinical goals to be satisfied under all setup errors within the uncertainty set, this is equivalent to maximizing the probability of satisfying the clinical goals. This type of robust optimization is studied with respect to photon and proton therapy applied to a prostate case and compared to robust optimization using an a priori defined uncertainty set. Results: Slight reductions of the uncertainty sets resulted in plans that satisfied a larger number of clinical goals than optimization with respect to a priori defined uncertainty sets, both within the reduced uncertainty sets and within the a priori, nonreduced, uncertainty sets. For the prostate case, the plans taking reduced uncertainty sets into account satisfied 1.4 (photons) and 1.5 (protons) times as many clinical goals over the scenarios as the method taking a priori uncertainty sets into account. Conclusions: Reducing the uncertainty sets enabled the optimization to find better solutions with respect to the errors within the reduced as well as the nonreduced uncertainty sets and thereby achieve higher probability of satisfying the clinical goals. This shows that asking for a little less in the optimization sometimes leads to better overall plan quality.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-204-03: DFT Calculations of the Stability of DOTA-Based-Radiopharmaceuticals

Purpose: Application of the density function theory (DFT) to investigate the structural stability of complexes applied in cancer therapy consisting of the 1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA) chelated to Ac225, Fr221, At217, Bi213, and Gd68 radio-nuclei. Methods: The possibility to deliver a toxic payload directly to tumor cells is a highly desirable aim in targeted alpha particle therapy. The estimation of bond stability between radioactive atoms and the DOTA chelating agent is the key element in understanding the foundations of this delivery process. Thus, we adapted the Vienna Ab-initio Simulation Package (VASP) with the projector-augmented wave method and a plane-wave basis set in order to study the stability and electronic properties of DOTA ligand chelated to radioactive isotopes. In order to count for the relativistic effect of radioactive isotopes we included Spin-Orbit Coupling (SOC) in the DFT calculations. Five DOTA complex structures were represented as unit cells, each containing 58 atoms. The energy optimization was performed for all structures prior to calculations of electronic properties. Binding energies, electron localization functions as well as bond lengths between atoms were estimated. Results: Calculated binding energies for DOTA-radioactive atom systems were −17.792, −5.784, −8.872, −13.305, −18.467 eV for Ac, Fr, At, Bi and Gd complexes respectively. The displacements of isotopes in DOTA cages were estimated from the variations in bond lengths, which were within 2.32–3.75 angstroms. The detailed representation of chemical bonding in all complexes was obtained with the Electron Localization Function (ELF). Conclusion: DOTA-Gd, DOTA-Ac and DOTA-Bi were the most stable structures in the group. Inclusion of SOC had a significant role in the improvement of DFT calculation accuracy for heavy radioactive atoms. Our approach is found to be proper for the investigation of structures with DOTA-based-radiopharmaceuticals and will enhance our understanding of processes occurring at subatomic levels.

60 APPLIED LIFE SCIENCES↗

TH-EF-BRB-10: Dosimetric Validation of a Trajectory Based Cranial SRS Treatment Technique On a Varian TrueBeam Linac

Purpose: This work investigates the dosimetric accuracy of a trajectory based delivery technique in which an optimized radiation beam is delivered along a Couch-Gantry trajectory that is formed by simultaneous rotation of the linac gantry and the treatment couch. Methods: Nine trajectory based cranial SRS treatment plans were created using in-house optimization software. The plans were calculated for delivery on the TrueBeam STx linac with 6MV photon beam. Dose optimization was performed along a user-defined trajectory using MLC modulation, dose rate modulation and jaw tracking. The pre-defined trajectory chosen for this study is formed by a couch rotation through its full range of 180 degrees while the gantry makes four partial arc sweeps which are 170 degrees each. For final dose calculation, the trajectory based plans were exported to the Varian Eclipse Treatment Planning System. The plans were calculated on a homogeneous cube phantom measuring 18.2×18.2×18.2 cm3 with the analytical anisotropic algorithm (AAA) using a 1mm3 calculation voxel. The plans were delivered on the TrueBeam linac via the developer’s mode. Point dose measurements were performed on 9 patients with the IBA CC01 mini-chamber with a sensitive volume of 0.01 cc. Gafchromic film measurements along the sagittal and coronal planes were performed on three of the 9 treatment plans. Point dose values were compared with ion chamber measurements. Gamma analysis comparing film measurement and AAA calculations was performed using FilmQA Pro. Results: The AAA calculations and measurements were in good agreement. The point dose difference between AAA and ion chamber measurements were within 2.2%. Gamma analysis test pass rates (2%, 2mm passing criteria) for the Gafchromic film measurements were >95%. Conclusion: We have successfully tested TrueBeam’s ability to deliver accurate trajectory based treatments involving simultaneous gantry and couch rotation with MLC and dose rate modulation along the trajectory.

60 APPLIED LIFE SCIENCES↗

Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamic sparse x-ray nanotomography reveals ionomer hydration mechanism in polymer electrolyte fuel-cell catalyst

Tomographic imaging of time-evolving samples is a challenging yet important task for various research fields. At the nanoscale, current approaches face limitations of measurement speed or resolution due to lengthy acquisitions. We developed a dynamic nanotomography technique based on sparse dynamic imaging and 4D tomography modeling. We demonstrated the technique, using ptychographic x-ray computed tomography as its imaging modality, on resolving the in situ hydration process of polymer electrolyte fuel cell (PEFC) catalyst. The technique provides a 40-time increase in temporal resolution compared to conventional approaches, yielding 28 nm half-period spatial and 12 min temporal resolution. The results allow a quantitative characterization of the water intake process inside PEFC catalysts with nanoscale resolution, which is crucial for understanding their electrochemical mechanisms and optimizing their performance. Our technique enables high-speed operando nanotomography studies and paves the way for wider application of dynamic tomography at the nanoscale.

Science & Technology - Other Topics↗

A gravity-based mounting approach for large-scale cryogenic calorimeter arrays

Cryogenic calorimeters are among the leading technologies for searching for rare events. The CUPID experiment is exploiting this technology to deploy a tonne-scale detector to search for neutrinoless double-beta decay of 100 Mo. The CUPID collaboration proposed an innovative approach to assembling cryogenic calorimeters in a stacked configuration, held in position solely by gravity. This gravity-based assembly method is unprecedented in the field of cryogenic calorimeters and offers several advantages, including relaxed mechanical tolerances and simplified construction. To assess and optimize its performance, we constructed a medium-scale prototype hosting 28 Li 2 MoO 4 crystals and 30 Ge light detectors, both operated as cryogenic calorimeters at the Laboratori Nazionali del Gran Sasso (Italy). Despite an unexpected excess of noise in the light detectors, the results of this test proved (i) a thermal stability better than ±0.5 mK at 10 mK, (ii) a good energy resolution of Li 2 MoO 4 cryogenic calorimeters, (6.6 ± 2.2) keV FWHM at 2615 keV, and (iii) a Li 2 MoO 4 light yield measured by the closest light detector of 0.36 keV/MeV, sufficient to guarantee the particle identification requested by CUPID.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Pushing the limits of pulse shape discrimination in a large liquid xenon detector

Abstract The LUX-ZEPLIN (LZ) experiment is a direct-detection dark matter experiment, optimized to search for weakly interacting massive particles (WIMPs) through WIMP-nucleon interactions. The main challenge in dark matter detection is differentiating between WIMP signals and background events. In LZ, the ratio of ionization to scintillation signals (charge-to-light) is the primary method for rejecting electronic recoil (ER) background. Pulse shape discrimination (PSD) offers a method for additional ER backgrounds rejection in liquid xenon detectors. In this paper, the discrimination power of PSD with the LZ experiment is discussed. To precisely characterize the scintillation pulse shape, an analysis framework is developed to reconstruct the detection time of individual photons. Using LZ calibration data, the photon-timing tail fraction discriminator is optimized and achieves ER leakage as low as $$15\%$$ 15 % . For specific background processes such as $$^{124}$$ 124 Xe double electron capture, the leakage is reduced further to about $$5\%$$ 5 % . PSD is combined with charge-to-light to form two-factor discrimination (TFD). The optimized TFD performance is compared with the performance of the charge-to-light method, with the corresponding false positive rate reduced by up to a factor of two for large scintillation pulses. Finally, PSD and TFD are applied to data from LZ’s WS2024 run and their performance is summarized.

Akerib, D. S. [SLAC National Accelerator Laborator↗

Future Circular Collider Feasibility Study Report

Volume 3 of the FCC Feasibility Report presents studies related to civil engineering, the development of a project implementation scenario, and environmental and sustainability aspects. The report details the iterative improvements made to the civil engineering concepts since 2018, taking into account subsurface conditions, accelerator and experiment requirements, and territorial considerations. It outlines a technically feasible and economically viable civil engineering configuration that serves as the baseline for detailed subsurface investigations, construction design, cost estimation, and project implementation planning. Additionally, the report highlights ongoing subsurface investigations in key areas to support the development of an improved 3D subsurface model of the region. The report describes the development of the project scenario based on the ‘avoid-reduce-compensate’ iterative optimisation approach. The reference scenario balances optimal physics performance with territorial compatibility, implementation risks, and costs. Environmental field investigations covering almost 600 hectares of terrain—including numerous urban, economic, social, and technical aspects—confirmed the project’s technical feasibility and contributed to the preparation of essential input documents for the formal project authorisation phase. The summary also highlights the initiation of public dialogue as part of the authorisation process. The results of a comprehensive socio-economic impact assessment, which included significant environmental effects, are presented. Even under the most conservative and stringent conditions, a positive benefit-cost ratio for the FCC-ee is obtained. Finally, the report provides a summary of the studies conducted to document the current state of the environment.

Benedikt, M. [European Organization for Nuclear Re↗

Locality-Aware CTA Clustering For Modern GPUs

In this paper, we proposed a novel clustering technique for tapping into the performance potential of a largely ignored type of locality: inter-CTA locality. We first demonstrated the capability of the existing GPU hardware to exploit such locality, both spatially and temporally, on L1 or L1/Tex unified cache. To verify the potential of this locality, we quantified its existence in a broad spectrum of applications and discussed its sources of origin. Based on these insights, we proposed the concept of CTA-Clustering and its associated software techniques. Finally, We evaluated these techniques on all modern generations of NVIDIA GPU architectures. The experimental results showed that our proposed clustering techniques could significantly improve on-chip cache performance.

Data Locality↗