Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

NASA Tech Briefs, November 2006

Topics include: Simulator for Testing Spacecraft Separation Devices; Apparatus for Hot Impact Testing of Material Specimens; Instrument for Aircraft-Icing and Cloud-Physics Measurements; Advances in Measurement of Skin Friction in Airflow; Improved Apparatus for Testing Monoball Bearings; High-Speed Laser Scanner Maps a Surface in Three Dimensions; Electro-Optical Imaging Fourier-Transform Spectrometer; Infrared Instrument for Detecting Hydrogen Fires; Modified Coaxial Probe Feeds for Layered Antennas; Detecting Negative Obstacles by Use of Radar; Cryogenic Pound Circuits for Cryogenic Sapphire Oscillators; PixelLearn; New Software for Predicting Charging of Spacecraft; Conversion Between Osculating and Mean Orbital Elements; Generating a 2D Representation of a Complex Data Structure; Making Activated Carbon by Wet Pressurized Pyrolysis; Composite Solid Electrolyte Containing Li+- Conducting Fibers; Electrically Conductive Anodized Aluminum Surfaces; Rapid-Chill Cryogenic Coaxial Direct-Acting Solenoid Valve; Variable-Tension-Cord Suspension/Vibration- Isolation System; Techniques for Connecting Superconducting Thin Films; Versatile Friction Stir Welding/Friction Plug Welding System; Thermal Spore Exposure Vessels; Enumerating Spore-Forming Bacteria Airborne with Particles; Miniature Oxidizer Ionizer for a Fuel Cell; Miniature Ion-Array Spectrometer; Promoted-Combustion Chamber with Induction Heating Coil; Miniature Ion-Mobility Spectrometer; Mixed-Salt/Ester Electrolytes for Low-Temperature Li+ Cells; Miniature Free-Space Electrostatic Ion Thrusters; Miniature Bipolar Electrostatic Ion Thruster; Holographic Plossl Retroreflectors; Miniature Electrostatic Ion Thruster With Magnet; Using Apex To Construct CPM-GOMS Models; Sequence Detection for PPM Optical Communication With ISI; Algorithm for Rapid Searching Among Star-Catalog Entries; Expectation-Based Control of Noise and Chaos; Radio Heating of Lunar Soil to Release Gases; Using Electrostriction to Manipulate Ullage in Microgravity; Equations for Scoring Rules When Data Are Missing; Insulating Material for Next-Generation Spacecraft; and Pseudorandom Switching for Adding Radar to the AFF Sensor.

Source record↗

Experimental instrumentation system for the Phased Array Mirror Extendible Large Aperture (PAMELA) test program

Adaptive optics are used in telescopes for both viewing objects with minimum distortion and for transmitting laser beams with minimum beam divergence and dance. In order to test concepts on a smaller scale, NASA MSFC is in the process of setting up an adaptive optics test facility with precision (fraction of wavelengths) measurement equipment. The initial system under test is the adaptive optical telescope called PAMELA (Phased Array Mirror Extendible Large Aperture). Goals of this test are: assessment of test hardware specifications for PAMELA application and the determination of the sensitivities of instruments for measuring PAMELA (and other adaptive optical telescopes) imperfections; evaluation of the PAMELA system integration effort and test progress and recommended actions to enhance these activities; and development of concepts and prototypes of experimental apparatuses for PAMELA.

Boykin, William H., Jr.↗

MOPITT Mechanisms 16 Years In-Orbit Operation on TERRA

The 16th anniversary of the launch of NASA's Terra Spacecraft was marked on December 18, 2015, with the Measurements of Pollution in the Troposphere (MOPITT) instrument being a successful contributor to the NASA EOS flagship. MOPITT has been enabled by a large suite of mechanisms, allowing the instrument to perform long-duration monitoring of atmospheric carbon monoxide, providing global measurements of this important greenhouse gas for 16 years. Mechanisms have been successfully employed for scanning, cooling of detectors, and to optically modulate the gas path length within the instrument by means of pressure and gas cell length variation. The instrument utilizes these devices to perform correlation spectroscopy, enabling measurements with vertical resolution from the nadir view, and has thereby furthered understanding of source and global transport effects of carbon monoxide. Given the design requirement for a 5.25-year lifetime, the stability and performance of the majority of mechanisms have far surpassed design goals. With 16 continuously operating mechanisms in service on MOPITT, including 12 rotating mechanisms and 4 with linear drive elements, the instrument was an ambitious undertaking. The long life requirements combined with demands for cleanliness and optical stability made for difficult design choices including that of the selection of new lubrication processes. Observations and lessons learned with regards to many aspects of the mechanisms and associated monitoring devices are discussed here. Mechanism behaviors are described, including anomalies, long-term drive current/power, fill pressure, vibration and cold-tip temperature trends. The effectiveness of particular lubrication formulations and the screening method implemented is discussed in relation to continuous rotating mechanisms and stepper motors, which have exceeded 15 billon rotations and 2.5 billion steps respectively. Aspects of gas cell hermeticity, optical cleanliness, heater problems and SEU effects on accelerometers are also discussed.

Gibson, Andrew S.↗

Development of an immersion fiber optic Raman probe for real-time analysis of molten materials

This study presents an advancement in high-temperature Raman spectroscopy, specifically for analyzing molten materials. It introduces an approach by integrating a fiber-optic Raman probe with a copper block protection system designed to endure extreme thermal conditions. The copper block features an open port designed to accommodate an external telescope with a 3 cm focal length, enabling Raman spectra collection in challenging high-temperature environments. A built-in gas channel ensures a continuous flow of argon gas to prevent flux intrusion. The robust copper block acts as a reliable shield, safeguarding the fiber-optic Raman probe within molten materials. This enhancement maintains the probe's integrity and significantly improves its resilience, making it ideal for rigorous investigations of molten substances. This advancement is particularly relevant in metallurgy, where flux materials impact production quality and efficiency. The ability to acquire Raman signals under elevated thermal conditions offers opportunities for studying molecular dynamics, compositional changes, and chemical interactions within molten substances. This introduced direct immersion probing technique has implications, benefiting both scientific and industrial fields. It holds promise for advancing research and exploration in various contexts, from fundamental scientific inquiries to practical applications in metallurgical processes, where flux materials are critical for optimizing production quality and efficiency. Furthermore, this approach enhances the capabilities of high-temperature Raman spectroscopy, making it a valuable tool for investigating molten materials and their properties in diverse settings.

Argon↗

The Design & Development of the Ocean Color Instrument Precision Superduplex Hybrid Bearing Cartridge

A high precision, high-resolution Ocean Color Imaging (OCI) instrument is under development for the Plankton, Aerosol, Cloud, ocean Ecosystem (PACE) mission which requires a pair of medium speed mechanisms to scan the ocean surface continuously. The design of the rotating telescope (RT) mechanism operating at 360 RPM and the half-angle mirror (HAM) mechanism synchronized at 180 RPM was concern for maintaining pointing precision over the required life and continuous operations. An effort was undertaken with the manufacturer to design and analyze a special bearing configuration to minimize axial and radial runout, minimize torque, and maintain nominal contact stresses and stiffness over the operating temperature range and to maximize life. The bearing design, development effort, analysis and testing will be discussed as will the technical challenges that this specific design imposed upon the mechanism engineers. Bearing performance, runout as achieved and verified during encoder installation and operating torque will be described.

mechanism↗

Optical emissivity dataset of multi-material heterogeneous designs generated with automated figure extraction

Optical device design is typically an iterative optimization process based on a good initial guess from prior reports. Optical properties databases are useful in this process but difficult to compile because their parsing requires finding relevant papers and manually converting graphical emissivity curves to data tables. Here, we present two contributions: one is a dataset of thermal emissivity records with design-related parameters, and the other is a software tool for automated colored curve data extraction from scientific plots. We manually collected 64 papers with 176 figures reporting thermal emissivity and automatically retrieved 153 colored curve data records. The automated figure analysis software pipeline uses Faster R-CNN for axes and legend object detection, EasyOCR for axes numbering recognition, and k-means clustering for colored curve retrieval. Additionally, we manually extracted geometry, materials, and method information from the text to add necessary metadata to each emissivity curve. Finally, we analyzed the dataset to determine the dominant classes of emissivity curves and determine the underlying design parameters leading to a type of emissivity profile.

47 OTHER INSTRUMENTATION↗

Modeling the Transmission of Optical Lightning Signals Through Complex 3‐D Cloud Scenes

Abstract Space‐based lightning imagers have shown that complex cloud scenes consisting of multiple tall convective features, anvil clouds, and warm boundary cloud layers are illuminated by lightning in many different ways depending on where the lightning occurs and how energetic it is. Modifications to the optical lightning signals from radiative transfer in the cloud medium can lead to reductions in detection efficiency and location accuracy for these instruments and can also cause some of the optical signals that are detected to have unexpected spatial energy distributions. In this study, we perform Monte Carlo radiative transfer simulations of optical lightning emissions in clouds with complex 3‐D geometries to shed some light on the origins of certain irregular radiance patterns that have been recorded from orbit. We show that diffuse reflections off nearby cloud faces can explain lightning signals in nonelectrified clouds, tall clouds can result in poor optical transmission and suppressed radiances that could lead to missed events and that particularly favorable viewing conditions can cause otherwise normal lightning to produce a superbolt that is orders of magnitude brighter than the same flash seen from a different angle.

54 ENVIRONMENTAL SCIENCES↗

The Diffuse Infrared Background Experiment (DIRBE) - Understanding through test and simulation

Optical problems which arose during final integration and testing of the DIRBE instrument in the closed flight dewar before launch are discussed. Simulation based on the optical breadboard and engineering unit components showed that these problems (stray light signals) originated outside the instrument in the dewar dome lid. Excellent performance of the instrument confirmed this fact.

Wood, H. J.↗

Contamination control program for the Extreme Ultraviolet Explorer instruments

A contamination-control program has been instituted for the optical components of the EUV Explorer satellite, whose 80-900 A range performance is easily degraded by particulate and molecular contamination. Cleanliness requirements have been formulated for the design, fabrication, and test phases of these instruments; in addition, contamination-control steps have been taken which prominently include the isolation of sensitive components in a sealed optics cavity. Prelaunch monitoring systems encompass the use of quartz crystal microbalances, particle witness plates, direct flight hardware sampling, and optical witness sampling of EUV scattering and reflectivity.

Ray, David C.↗

Complex multicomponent spectrum analysis with Deep Neural Network

Here, in this paper, we present the use of deep neural networks to estimate physical parameters from complex optical emission spectra of the D β /H β transition. Specifically, we focus on estimating the radio frequency electric field vector of the lower hybrid wave and isotope ratio within the scrape-off-layer plasma of the WEST tokamak. Fitting the spectral data using a traditional non-linear least squares analysis requires many free parameters and is computationally expensive, rendering the data unusable for real-time control. By implementing relatively small neural networks, the physical parameters can be directly extracted from the spectral data with reasonable accuracy in a few milliseconds. The deep neural network prediction can serve as input for a reduced model using least-squares fitting or for real-time control. We show that deep neural networks can be an effective tool for analyzing complex multicomponent spectra, providing a speedup of more than 10 5 times compared to least residual analysis, with an accuracy of 0.5% for the isotope ratio, and 0.09 kV/cm and 0.38 kV/cm for the RF radial and poloidal electric field respectively.

47 OTHER INSTRUMENTATION↗

Light-sheet autofluorescence lifetime imaging with a single-photon avalanche diode array

Significance: Fluorescence lifetime imaging microscopy (FLIM) of the metabolic co-enzyme nicotinamide adenine dinucleotide (phosphate) [NAD(P)H] is a popular method to monitor single-cell metabolism within unperturbed, living 3D systems. However, FLIM of NAD(P)H has not been performed in a light-sheet geometry, which is advantageous for rapid imaging of cells within live 3D samples. Aim: We aim to design, validate, and demonstrate a proof-of-concept light-sheet system for NAD(P)H FLIM. Approach: A single-photon avalanche diode camera was integrated into a light sheet microscope to achieve optical sectioning and limit out-of-focus contributions for NAD(P)H FLIM of single cells. Results: An NAD(P)H light-sheet FLIM system was built and validated with fluores cence lifetime standards and with time-course imaging of metabolic perturbations in pancreas cancer cells with 10 s integration times. NAD(P)H light-sheet FLIM in vivo was demonstrated with live neutrophil imaging in a larval zebrafish tail wound also with 10 s integration times. Finally, the theoretical and practical imaging speeds for NAD(P)H FLIM were compared across laser scanning and light-sheet geometries, indicating a 30× to 6× acquisition speed advantage for the light sheet compared to the laser scanning geometry. Conclusions: FLIM of NAD(P)H is feasible in a light-sheet geometry and is attrac tive for 3D live cell imaging applications, such as monitoring immune cell metabolism and migration within an organism.

47 OTHER INSTRUMENTATION↗

The Infrared Telescope in Space (IRTS) Mission

The Infrared Telescope in Space is a cryogenically-cooled NASA/ISAS space survey instrument scheduled for a February, 1995 launch. The telescope optical system is optimized for studies of extended low surface-brightness objects. Four focal-plane instruments cover wavelengths ranging form 1 to 800 microns.

Roellig, Thomas L.↗

Assessment of Global Cloud Datasets from Satellites: Project and Database Initiated by the GEWEX Radiation Panel

Clouds cover about 70% of the Earth's surface and play a dominant role in the energy and water cycle of our planet. Only satellite observations provide a continuous survey of the state of the atmosphere over the whole globe and across the wide range of spatial and temporal scales that comprise weather and climate variability. Satellite cloud data records now exceed more than 25 years in length. However, climatologies compiled from different satellite datasets can exhibit systematic biases. Questions therefore arise as to the accuracy and limitations of the various sensors. The Global Energy and Water cycle Experiment (GEWEX) Cloud Assessment, initiated in 2005 by the GEWEX Radiation Panel, provided the first coordinated intercomparison of publically available, standard global cloud products (gridded, monthly statistics) retrieved from measurements of multi-spectral imagers (some with multiangle view and polarization capabilities), IR sounders and lidar. Cloud properties under study include cloud amount, cloud height (in terms of pressure, temperature or altitude), cloud radiative properties (optical depth or emissivity), cloud thermodynamic phase and bulk microphysical properties (effective particle size and water path). Differences in average cloud properties, especially in the amount of high-level clouds, are mostly explained by the inherent instrument measurement capability for detecting and/or identifying optically thin cirrus, especially when overlying low-level clouds. The study of long-term variations with these datasets requires consideration of many factors. A monthly, gridded database, in common format, facilitates further assessments, climate studies and the evaluation of climate models.

Stubenrauch, C. J.↗

Combined Optical and Radio–Frequency Perspectives on the Time Evolution of Lightning Measured by the FORTE Satellite

We use a cluster feature data set for the Fast On-orbit Recording of Transient Events (FORTE) satellite that combines detections from its pixelated Lightning Locating System (LLS), photodiode detector (PDD) and Radio-Frequency (RF) instrumentation to generate statistics describing the frequency and timing of lightning events detected by each instrument during lightning flashes. Coincident observations from the same vantage point allow us to directly compare flash details that can be resolved by the wide Field of View (FOV) instruments relative to the pixelated LLS—whose design is based on NASA's Lightning Imaging Sensor. We find that both the PDD and RF system typically generate more detections than the lightning imager (mean: 1.5 PDD events per LLS group, 2 RF events per LLS group) from pulses that are either not sufficiently bright in the optical band (in the case of RF) or that lack the optical energy density (in the case of the PDD) required to trigger one of the pixels on the LLS imaging array. This includes additional activity before the first LLS group or after the final LLS group. These FORTE results demonstrate that certain lightning processes would be better resolved by wide-FOV optical and RF instruments than lightning imagers. Current/future space-based missions that use/plan to use similar instruments will improve our understanding of flash evolution by resolving details missed by lightning imagers.

47 OTHER INSTRUMENTATION↗

Next-generation neutron detection using a 6 Li glass scintillator composite

Neutron detectors are crucial in fundamental science, nuclear security, safeguards, and civil applications. 3 He-filled gas proportional counters are the gold standard for thermal neutron detection, prized for their efficiency, neutron/gamma discrimination, and stability; however, the scarcity of 3 He has prompted the search for alternatives. Here, we introduce a neutron detector design based on a scintillating composite consisting of 6 Li glass scintillator particles dispersed in an organic matrix. A detector consisting of this scintillating composite, photomultiplier tubes (PMTs) for optical detection, and electronics for reading out the PMT signal in both pulse and current modes was prototyped and characterized using various neutron and gamma sources. The prototype achieves a measured intrinsic detection efficiency of 6.70 ± 0.01%, a die-away time of 10.3 ± 0.1 μs, a negligible gamma misidentification probability, and response linearity up to at least 3.7 × 10 6 incident neutrons/s established via a cross-calibration technique. This detector holds the potential to outperform traditional 3 He-gas-based neutron detection systems, offering a viable alternative amidst the ongoing 3 He shortage and promising advancements in neutron detection technology.

47 OTHER INSTRUMENTATION↗

Novel Fiber Optic Sensing Arrays with Enhanced Sensitivity in Cryogenic Temperatures

State-of-the-art instrumentation techniques have provided an opportunity to obtain greater insight into the characteristics of cryogenic liquid storage. Optical fiber sensors that utilize fiber Bragg gratings are a viable option for temperature sensing in volatile liquid such as liquid oxygen because there is no risk of electrical sparking and no electromagnetic interference. The National Aeronautics and Space Administration (NASA) Armstrong Flight Research Center (Edwards, California) has developed a novel, simple-to-fabricate fiber array sensor that has been tested and found to be three times more sensitive than typical fiber sensors under cryogenic condition (traditional fiber sensors can suffer from reduced sensitivity below 100 K). Cryogenic temperature monitoring using the NASA fiber optic sensing system is demonstrated in a simulated cryostatic condition, as well as in an elevated pressure environment under liquid nitrogen. Measurement accuracy is compared with traditional silicon diodes. Instrument installation, sensor characteristics, and experimental results are discussed in detail.

Hon Man Chan↗

Direct LiF imaging diagnostics on refractive X-ray focusing at the EuXFEL High Energy Density instrument

The application of fluorescent crystal media in wide-range X-ray detectors provides an opportunity to directly image the spatial distribution of ultra intense X-ray beams including investigation of the focal spot of free-electron lasers. Here the capabilities of the micro- and nano-focusing X-ray refractive optics available at the High Energy Density instrument of the European XFEL are reported, as measured in situ by means of a LiF fluorescent detector placed into and around the beam caustic. The intensity distribution of the beam focused down to several hundred nanometers was imaged at 9 keV photon energy. A deviation from the parabolic surface in a stack of nanofocusing Be compound refractive lenses (CRLs) was found to affect the resulting intensity distribution within the beam. Comparison of experimental patterns in the far field with patterns calculated for different CRL lens imperfections allowed the overall inhomogeneity in the CRL stack to be estimated. The precise determination of the focal spot size and shape on a sub-micrometer level is essential for a number of high energy density studies requiring either a pin-size backlighting spot or extreme intensities for X-ray heating.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A Compact Dual-Crystal Modulated Birefringence-Measurement System for Microgravity Applications

A compact modulated birefringence-measurement system has been developed for use in microgravity fluid physics applications with non-Newtonian fluids such as polymer solutions. This instrument uses a dual-crystal transverse electro-optical modulator capable of modulation frequencies in excess of 100 MHz. The two crystals are modulated 180 deg. out of phase from each other, The theoretical framework governing the development of this instrument using the Mueller-Stokes polarization matrices is discussed. Several ground-based experiments are performed to compare this system with the theoretical results. Results from this transverse electro-optical modulator-based birefringence-measurement system agree well with the theory. The instrument is also very stable and robust, making it suitable for the extreme acceleration environment to be encountered in a NASA Black Brandt sounding rocket.

Mackey, Jeffrey R.↗