At least 1,657 records · Page 92

Measuring Impact: Evaluating Thermal Zoning Simplification on Energy Efficiency Measures Analysis

Building Energy Modeling (BEM) is a versatile tool for designing, retrofitting, ensuring code compliance, obtaining certifications, qualifying for incentives, and enabling real-time building control. However, capturing all the details of building geometry for thermal zoning can be time-consuming, costly, and sometimes computationally challenging. As a result, modelers have been applying zoning simplification based on factors such as space functions and internal loads, as well as relying on their experience and judgment while adhering to zoning rules outlined in industry standards. Despite the prevalence of this common practice, a notable gap exists in the literature regarding studies quantifying the influence of simplified thermal zoning on the evaluation of Energy Efficiency Measures (EEMs). Recognizing this gap, this paper seeks to contribute to the field by enhancing the understanding of how the simplification of thermal zoning influences the evaluation of EEMs against a baseline design. The study utilized a medium office prototype model with a detailed floor plan featuring over 20 zones per floor covering diverse functional spaces with varying internal loads and occupancy schedules. A standard thermal zoning strategy outlined in ASHRAE Standard 90.1 Appendix G was employed as the simplified zoning method. This strategy condenses the zoning into a core zone and four perimeter zones per floor. It was compared with the detailed zoning approach, which involves one zone per space. Common Energy EEMs, such as enhanced envelope, high-efficiency appliances and equipment, and HVAC controls, were individually implemented and evaluated. The results indicate that the performance comparison between the two zoning methods varies depending on the type of measures considered. Basic measures, such as adding wall insulation, demonstrate similar energy impacts, while advanced HVAC control measures, such as static pressure reset, exhibit a more substantial difference that cannot be overlooked.

Xie, Jiarong↗

Building Energy Analysis of Manufactured and Multifamily Housing Types in Juneau, Alaska

This report details the results of building energy modeling analysis evaluating the potential energy savings, economic outcomes, and grid-level electricity reduction associated with cold climate air source heat pump (ccASHP) adoption across multifamily and manufactured housing (MMFH) building typologies in the City and Borough of Juneau (CBJ). Three building archetypes were evaluated: multifamily 4-plex apartments, multifamily 8-plex apartments, and manufactured housing units. Building energy models were developed using OpenStudio-HPXML and calibrated to actual utility consumption data and local meteorological data from the Juneau International Airport weather station using an automated calibration tool following the BPI-2400-S-2015 v.2 standard for model calibration. Occupant behaviors present the greatest variability in successful calibrations. Calibrated models were benchmarked against a baseline electric resistance heating condition, with the selected ccASHP modeled as the retrofit condition and typical meteorological year weather data for all results generation.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Field Validation of a Grid-Interactive Efficient Building Software Solution

The U.S. General Services Administration's (GSA's) Green Proving Ground (GPG) program, in partnership with the National Laboratory of the Rockies (NLR), completed a field study of a Grid-Interactive Efficient Buildings (GEB) software solution. The study focused on a single testbed facility to test the GEB functionality of the software solution, along with other features. The testbed facility - a courthouse - is a common building type in GSA's vast building portfolio, offering potentially impactful findings on a scalable level. The study evaluated Prescriptive Data's technology, Nantum OS, a connected building operating system ("GEB Solution") which aggregates multiple sources of previously siloed building data and combines that data with external sources, such as weather information or utility signals, into a single integrated platform. A GEB Solution is a type of Energy Management Information System (EMIS). EMIS is defined as a system of devices, data services, and software applications that communicates with any building system or third-party data source to aggregate and transform data into new capabilities to aid in the optimization of energy use at the building, campus, or agency level. This specific GEB Solution is an EMIS with ASO, automated system optimization, offering supervisory control of certain aspects of the Building Automation System (BAS). Multiple features were evaluated including, but not limited to, Continuous Demand Management to avoid setting new monthly kilowatt (kW) peaks, energy efficiency for reduction of kilowatt hours (kWh) and natural gas consumption, and automated demand response (ADR) for purposes of lowering demand during a utility called Demand Response (DR) event. The testbed facility was the Foley Federal Building and US Courthouse ("Foley Federal Building") located in Las Vegas, NV. This is a 209,496 sq. ft. building constructed in the 1960s with major renovations in 2004. The facility was a good candidate due to the large prevalence of office and courthouse spaces in the GSA portfolio of buildings. It also has many features which allow integration into and control of the building and a strong facilities team to assist with the study. Quantitative and qualitative performance objectives were developed using GSA's GPG GEB project template along with input from the vendor and building facility staff; these are outlined in Table 1. The quantitative performance objectives focused on continuous demand management, energy efficiency, and automated demand response. The qualitative performance objectives focused on the ease of installation and commissioning as well as the operability of the GEB solution. Other performance metrics that are reported on include carbon reduction, cost effectiveness, and occupant acceptance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The fluoride permeation pathway and anion recognition in Fluc family fluoride channels

Fluc family fluoride channels protect microbes against ambient environmental fluoride by undermining the cytoplasmic accumulation of this toxic halide. These proteins are structurally idiosyncratic, and thus the permeation pathway and mechanism have no analogy in other known ion channels. Although fluoride-binding sites were identified in previous structural studies, it was not evident how these ions access aqueous solution, and the molecular determinants of anion recognition and selectivity have not been elucidated. Using x-ray crystallography, planar bilayer electrophysiology, and liposome-based assays, we identified additional binding sites along the permeation pathway. We used this information to develop an oriented system for planar lipid bilayer electrophysiology and observed anion block at one of these sites, revealing insights into the mechanism of anion recognition. We propose a permeation mechanism involving alternating occupancy of anion-binding sites that are fully assembled only as the substrate approaches.

59 BASIC BIOLOGICAL SCIENCES↗

Hyperfine Splitting and Nuclear Spin Polarization in NdPd 5 Al 2 and Nd 3 Pd 20 Ge 6

Here the hyperfine splitting of Nd nuclei in NdPd 5 Al 2 was studied by means of high-resolution neutron spectroscopy. We observed inelastic peaks at ℏω = ±3 µeV and T = 0.3 K, originating from the hyperfine splitting in the magnetically ordered phase owing to the hyperfine interactions between Nd nuclei (I = 7/2) and the 4f electrons with the Γ 6 ground state composed of mainly |±9/2$\rangle$. At very low temperatures, the nuclear spin of Nd is polarized with an increasing occupation probability of low energy levels and contributes to the enhancement of the antiferromagnetic Bragg intensities; the elastic non-spin-flip channel is dominant. As an application of this phenomenon, we determined the Nd moment and hyperfine splitting from the temperature dependence of an antiferromagnetic Bragg intensity for Nd 3 Pd 20 Ge 6 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Block Scale Rooftop Solar Technical Potential for the City of Orlando

The html maps are provided as supplementary information for the publication titled Parcel Scale Assessment of Rooftop Solar Technical Potential (NREL/PR-7A40-80780). The maps contain information on rooftop solar technical potential at the block scale for the city of Orlando in Florida. The rooftop solar technical potential information is based on data from two different datasets. The first dataset is LiDAR data for the city of Orlando obtained from the Orlando Utilities Commission (OUC) (Koebrich et al. 2021). The second dataset is a national parcel dataset (HIFLD 2020) which contains descriptive data and geometries for parcels in the U.S. Parcel scale data from both these datasets have been processed and aggregated to block scale to produce these html maps. The first html map (block scale developable roof area for Orlando) contains the developable roof area for solar. The second html map (block scale rooftop solar technical potential for Orlando) contains the rooftop solar technical potential in units of kilowatts as well as additional information on the most common building use type and the most common building occupancy type for the block. These html maps are provided to demonstrate the proof-of-concept analysis conducted for Orlando.

14 SOLAR ENERGY↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

VISUAL CONTROL OF RENDEZVOUS

Space rendezvous involving human occupants will be required in many phases of space flight. In order that rendezvous capability be concurrent with other phases of manned space flight to insure that such tasks as the rotation and addition of crews for manned space station, supply of stations and launching complexes for deep-space probes, and the emergency rescue of personnel may be carried out, it is desirable to determine the ability of a human pilot to control the rendezvous maneuver. The National Aeronautics and Space Administration has conducted a study program to determine vehicle requirements and control techniques for a number of proposed methods for performing piloted space rendezvous. The final step in each phase of the rendezvous study program has been a simulation of the man-machine combination to test its feasibility. Initially, an analytical study was conducted to determine a range of conditions that would exist at the beginning of the terminal phase of rendezvous (ref. 1). Piloted systems were investigated for rendezvous control using these initial conditions. One such study of piloted rendezvous in which all the required control information was displayed to the simulator pilot on instruments is presented in reference 2. While the control of the rendezvous maneuver by use of the instrument display was shown to be feasible, the sufficiently accurate measurement of the necessary information to operate the instrument was realized to be a difficult problem. Consideration was therefore given to the possibility of maneuvering range and range rate required for the control of the rendezvous from visual sightings made during the initial control application. To provide this capability, an analytical study was made. This analytical study, presented in reference 3, derived three techniques for obtaining range and range rate visually and conducted a simplified preliminary situation to test the three analytical techniques. The study reported herein is a continuation of the simulation work begun in reference 3, and is aimed at determining the ability of a pilot to use visual information to reduce or eliminate the need for some or all of the data that would normally be displayed on instruments.

Rendezvous↗

EFFECTS OF HIGH G CONDITIONS ON PILOT PERFORMANCE

The general development trend in space vehicle design suggests the desirability of maximally using the occupant to both control capsule attitude and to monitor vehicle systems during the boost (and reentry) acceleration phases, as well as during orbital flight. Consequently, much more information is needed concerning man's ability to perform certain control functions under conditions in which he is exposed to accelerations which approach not only his physiological tolerance limits, but also his performance tolerance limits. In addition to the need for more data concerning the acceleration stress that man can endure and still retain the ability to perform control functions, there is a need to know specifically the nature of performance errors which can arise, not only as the direct result of acceleration, but also as secondary effects of acceleration inter acting with other conditions such as the type of control task, the type of control device, the damping and stability parameters, and the pilot's physiological endurance8 . Current concern over the performance capabilities of the human pilot immersed in certain acceleration environments is well founded since there are very few experimental reports describing the effects of these conditions on performance. The present paper attempts to summarize some of the results of recent studies conducted at the Aviation Medical Acceleration Laboratory (AMAL) in which specific pilot performance capabilities were studied under several conditions of acceleration stress.

Gravity↗

Van Allen Discovery Most Important

The first step toward the exploration of space occurred approximately 22 months ago as a part of the International Geophysical Year. In the short interval since October, 1957, the new tools of research, the satellite and the space rocket, have produced two unexpected results of fundamental scientific importance. First, instruments placed in the Explorer satellites by James A. Van Allen have revealed the existence of layers of energetic particles in the outer atmosphere. This discovery constitutes the most significant research achievement of the IGY satellite program. The layers may provide the explanation for the aurora and other geophysical phenomena, and they will also influence the design of vehicles for manned space flight, whose occupants must be shielded against their harmful biological effects. Second, the shape of the earth has been determined very accurately with the aid of data from the first Vanguard. As a result of this investigation, we have found that our planet tends toward the shape of a pear, with its stem at the North Pole. This discovery may produce major changes in our ideas on the interior structure of the earth.

Jastrow, R.↗

Classification and Evaluation of Coherent Synchronous Sampled-Data Telemetry Systems

This paper analyzes the various types of continuous wave and pulse modulation for the transmission of sampled data over channels perturbed by white gaussian noise. Optimal coherent synchronous detection schemes for all the different modulation methods are shown to belong to one of two general classes: linear synchronous detection and correlation detection. The figures of merit, mean-square signal-to-error ratio and bandwidth occupancy, are determined for each system and compared.

Viterbi, Andrew↗

Hydroponics or Soilless Culture

Historically, hydroponics is not a new field; plant physiologists have known and used it for some 100 years. Inevitably, some enthusiasts got carried away.Claims were made of enormous potential yields; skyscraper tops were said to be capable of producing enough food for all of their occupants; and closets, basements, garages, etc. were wishfully converted into fields for hydroponic culture. Numerous publications on the subject appeared during this period. Basic requirements for hydropinc techniques are given along with examples of where soilless culture has been used commercially.

Chapman, H. D.↗

Radiography. Volume 2 - Radiation safety

Radiation measurement techniques and devices, occupational and other dosages, personnel protection, and other aspects of radiation safety - programmed text on nondestructive tests

Source record↗

Recent progress in navigation satellites.

Navigation satellites system designed for ATC without requirement for onboard transmitter, discussing spectrum occupancy, satellite power, lane ambiguities and computational procedures

Keane, L. M.↗

Recent progress in navigation satellites.

Navigation satellites system designed for ATC without requirement for onboard transmitter, discussing spectrum occupancy, satellite power, lane ambiguities and computational procedures

Keane, L. M.↗

High mobility work station restraint support

Chair holds man in semistanding posture enabling astronauts to work comfortably with minimum restriction in weightless environment. Seat, angled at 130 deg to back support, twists and swivels up to 20 deg in all directions but forward. Two flexible thigh clips prevent occupant from slipping off.

Schermerhorn, R. S.↗