Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutron detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Method for registration of solar cosmic rays by detecting neutrons

We consider a method of detecting the ionizing component of solar cosmic rays (SCRs) with energy from tens of MeV to tens of GeV by measuring the energy loss of SCR protons and light nuclei in scintillators and the multiplicity of the local neutron generation in a converter. Scintillation detectors based on stilbene, lithium glass, and solid-state photomultiplier tubes are capable of detecting fast neutrons with a temporal resolution of 10 ns and rejecting the gamma-ray background in the measuring system. The method will allow investigating the nucleon components of primary SCRs in circumterrestrial space.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Prototype Neutron Energy Spectrometer

The project goals are: (1) Use three to five pressurized helium tubes with varying polyethylene moderators to build a neutron energy spectrometer that is most sensitive to the incident neutron energy of interest. Neutron energies that are of particular interest are those from the fission neutrons (typically around 1-2 MeV); (2) Neutron Source Identification - Use the neutron energy 'selectivity' property as a tool to discriminate against other competing processes by which neutrons are generated (viz. Cosmic ray induced neutron production [ship effect], [a, n] reactions); (3) Determine the efficiency as a function of neutron energy (response function) of each of the detectors, and thereby obtain the composite neutron energy spectrum from the detector count rates; and (4) Far-field data characterization and effectively discerning shielded fission source. Summary of the presentation is: (1) A light weight simple form factor compact neutron energy spectrometer ready to be used in maritime missions has been built; (2) Under laboratory conditions, individual Single Neutron Source Identification is possible within 30 minutes. (3) Sources belonging to the same type of origin viz., (a, n), fission, cosmic cluster in the same place in the 2-D plot shown; and (4) Isotopes belonging to the same source origin like Cm-Be, Am-Be (a, n) or Pu-239, U-235 (fission) do have some overlap in the 2-D plot.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

C$^{7}$LYC: A New Scintillator for Fast Neutron Spectroscopy

The scintillator Cs 2 LiYCl 6 (CLYC) has emerged as a versatile detector for both gammas and neutrons, with excellent pulse shape discrimination. Originally developed as a thermal neutron counter, the discovery of its unexpected and unprecedented ~10% pulse height resolution for fast neutrons in the few MeV range has prompted studies to benchmark its use in low-energy nuclear science and applications. Since the typical long time-of-flight arms are not needed for achieving good energy resolution, geometrical efficiency can be enhanced by positioning the detectors much closer to the target. We have constructed a 16-element array of 1” × 1”7Li-enriched C 7 LYC, to eliminate the dominant peak in the spectrum from thermal neutron capture on 6Li, leaving the energy region above 3 MeV with a clean baseline for fast neutron spectroscopy. We have also procured the first ever 3” × 3” C 7 LYC crystal. Test experiments under way with C 7 LYC include elastic and inelastic neutron scattering cross sections at Los Alamos with a pulsed white neutron source, efficiency measurements using mono-energetic neutron beams up to a few MeV at UMass Lowell, and fission neutron measurements with GRETINA and CHICO detector arrays at Argonne. Beta-delayed neutron spectroscopy experiments have also been initiated at the CARIBU and NSCL facilities, to evaluate C 7 LYC as a possible candidate for auxiliary scintillator arrays for stopped beam physics at the next generation rare isotope accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Comparison of CF4 and SF6 based plasmas for ECR etching of isotopically enriched 10Boron films

Isotopically enriched {sup 10}boron films have been successfully etched in an ECR etching tool using CF{sub 4} and SF{sub 6} based plasmas. Comparisons between the two are made with regards to etch rate, selectivity to the underlying Si device structure, and morphology of the {sup 10}boron post-etching. The present film etching development is expected to be critical for the fabrication of next generation thermal neutron solid state detectors based on {sup 10}boron.

42 ENGINEERING↗

Commissioning of the BRIKEN detector for the measurement of very exotic β -delayed neutron emitters

A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and -ray detectors. We describe here the setup, the commissioning experiment and some selected results demonstrating its performance for the measurement of half-lives and β-delayed neutron emission probabilities. Here, the methodology followed in the analysis of the data is described in detail. Particular emphasis is placed on the correction of the accidental neutron background.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optimization of irradiation conditions for {sup 177}Lu production at the LVR-15 research reactor

The use of lutetium in medicine has been increasing over the last few years. The {sup 177}Lu radionuclide is commercially available for research and test purposes as a diagnostic and radiotherapy agent in the treatment of several malignant tumours. The yield of {sup 177}Lu from the {sup 176}Lu(n,{gamma}){sup 177}Lu nuclear reaction depends significantly on the thermal neutron fluence rate. The capture cross-sections of both reaction {sup 176}Lu(n,{gamma}){sup 177}Lu and reaction {sup 177}Lu(n,{gamma}){sup 178}Lu are very high. Therefore a burn-up of target and product nuclides should be taken into account when calculating {sup 177}Lu activity. The maximum irradiation time, when the activity of the {sup 177}Lu radionuclide begins to decline, was found for different fluence rates. Two vertical irradiation channels at the LVR-15 nuclear research reactor were compared in order to choose the channel with better irradiation conditions, such as a higher thermal neutron fluence rate in the irradiation volume. In this experiment, lutetium was irradiated in a titanium capsule. The influence of the Ti capsule on the neutron spectrum was monitored using activation detectors. The choice of detectors was based on requirements for irradiation time and accurate determination of thermal neutrons. The following activation detectors were selected for measurement of the neutron spectrum: Ti, Fe, Ni, Co, Ag and W. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validation of the MCNPX-PoliMi Code to Design a Fast-Neutron Multiplicity Counter

Many safeguards measurement systems used at nuclear facilities, both domestically and internationally, rely on He-3 detectors and well established mathematical equations to interpret coincidence and multiplicity-type measurements for verifying quantities of special nuclear material. Due to resource shortages alternatives to these existing He-3 based systems are being sought. Work is also underway to broaden the capabilities of these types of measurement systems in order to improve current multiplicity analysis techniques. As a part of a Material Protection, Accounting, and Control Technology (MPACT) project within the U.S. Department of Energy's Fuel Cycle Technology Program we are designing a fast-neutron multiplicity counter with organic liquid scintillators to quantify important quantities such as plutonium mass. We are also examining the potential benefits of using fast-neutron detectors for multiplicity analysis of advanced fuels in comparison with He-3 detectors and testing the performance of such designs. The designs are being developed and optimized using the MCNPX-PoliMi transport code to study detector response. In the full paper, we will discuss validation measurements used to justify the use of the MCNPX-PoliMi code paired with the MPPost multiplicity routine to design a fast neutron multiplicity counter with liquid scintillators. This multiplicity counter will be designed with the end goal of safeguarding advanced nuclear fuels. With improved timing qualities associated with liquid scintillation detectors, we can design a system that is less limited by nuclear materials of high activities. Initial testing of the designed system with nuclear fuels will take place at Idaho National Laboratory in a later stage of this collaboration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigations of radiation damaged arranged scintillating particle composites

Composites consisting of periodically arranged scintillating particles within an acrylic (poly methyl methacrylate) matrix are excellent templates for the gamma-insensitive detection of fast neutrons. In order to study the impact of radiation damage on acrylic-based scintillating particle composites, we exposed acrylic samples to different doses of fast neutrons up to 119.7 kGy and investigated the change in optical characteristics using optical absorption spectroscopy in the 200–800 nm wavelength range. The experimental results are compared to coupled MCNP6 and optical ray-tracing (FRED) simulations, and qualitative agreement is found. Neutron-induced radiation damage in the acrylic matrix manifests as a red-shift in the ultra-violet absorption edge of the acrylic and a corresponding decrease in the light propagation efficiency, which leads to detector performance degradation. We show for the first time that the effects of radiation damage can be mitigated by the use of wavelength-shifting coatings. We predict that composites with wavelength-shifting coatings can enable neutron detectors with high tolerance against neutron-induced radiation damage, a property that is particularly desired for neutron detection in high radiation environments.

36 MATERIALS SCIENCE↗

Inspection of the objects on the sea floor by using 14 MeV tagged neutrons

Variety of objects found on the sea floor needs to be inspected for the presence of materials which represent the threat to the environment and to the safety of humans. We have demonstrated that the sealed tube 14 MeV neutron generator with the detection of associated alpha particles can be used underwater when mounted inside ROV equipped with the hydraulic legs and variety of sensors for the inspection of such objects for the presence of threat materials. Such a system is performing the measurement by using the NaI gamma detector and an API-120 neutron generator which could be rotated in order to maximize the inspected target volume. The neutron beam intensity during the 10-30 min. measurements is usually 1 x 10{sup 7} n/s in 4{pi}. In this report the experimental results for some of commonly found objects containing TNT explosive or its simulant are presented. The measured gamma spectra are dominant by C, O and Fe peaks enabling the determination of the presence of explosives inside the ammunition shell. Parameters influencing the C/O ratio are discussed in some details. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on Associated-Particle Imaging Algorithms, 2022

The present work describes progress on developing imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating among critical materials or extracting three-dimensional (3D) geometrical information from single-sided or transmission measurements. The present work is divided into three approaches: 1.Iterative reconstruction of inelastic gamma-ray emissions to perform 3D time-of-flight (TOF) imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution. 2.Decomposition of registered neutron and x-ray radiographs into an assumed material list for each pixel in the image. 3.Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles. Progress for each approach is summarized for fiscal year (FY) 2022.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Direction-Sensitive Detector for Electron Antineutrinos

A modular design is proposed for an electron antineutrino detector based on boron-doped liquid scintillator. Tests have been carried out on small detector systems using neutrons to simulate the antineutrino detection signature. Results from these tests are reported, and the possibility of using a larger system of similar design to detect reactor antineutrinos is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress on Associate-Particle Imaging Algorithms, 2020

The present work describes progress on the development of imaging algorithms that use fast neutron signatures acquired using the associated-particle imaging (API) method. The present work complements ongoing work to develop neutron source and detector hardware to enable field inspection by investigating algorithms that are capable of discriminating between critical materials or extracting three-dimensional geometrical information from single-sided or transmission measurements. The present work is divided into three approaches:(1)Iterative reconstruction of inelastic gamma-ray emissions to perform three-dimensional time-of-flight imaging in a single view in either transmission or backscatter configurations. Iterative reconstruction enables image resolution better than the inherent TOF resolution.(2)Decomposition of registered neutron and x ray radiographs into an assumed material list for each pixel in the image.(3)Material identification using full spectral analysis that includes the emergent neutron and gamma ray energies, times, and angles.Progress for each approach is summarized for fiscal year 2020.

97 MATHEMATICS AND COMPUTING↗

Multi-depth Measurement of Fast Neutrons

A spallation based multiplicity detector has been constructed and deployed to the Kimballton Underground Research Facility to measure the cosmogenic fast neutron flux anti-coincident from the initiating muon. Two of the three planned measurements have been completed (~380 and ~600 m.w.e) with sufficient statistics. The third measurement at level 14 (~4450 m.w.e.) is currently being performed. Current results at ~600 m.w.e. compare favourably to the one previous measurement at 550 m.w.e. For neutron energies between 100 and 200 MeV measurements at ~380 m.w.e. produce fluxes between 1e -8 and 7e -9 n/cm 2 /s/MeV and at ~600 m.w.e. measurements produce fluxes between 7e -9 and 1e -11 n/cm 2 /s/MeV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The design and implementation of the AVNG measurement system

An attribute measurement system (AMS) measures a number of unclassified attributes of potentially classified material. By displaying these unclassified results only as red or green lights, the AMS protects potentially classified information while still generating confidence in the measurement result. The AVNG that we describe is an AMS built by RFNC-VNIIEF in Sarov, Russia. The AVNG detects neutron and gamma radiation signatures and displays the three unclassified attributes of 'plutonium presence,' 'plutonium mass >2 kg,' and 'plutonium isotopic ratio ({sup 240}Pu to {sup 239}Pu) < 0.1.' In this presentation, we will describe the design of the AVNG neutron and gamma detector subsystems, as well as the design of the entire AMS incorporating these detectors. We will also describe the construction of the AVNG and the final design that was demonstrated in June 2009.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Neutron fluence and energy reconstruction with the IRSN recoil detector μ-TPC at 27 keV, 144 keV and 565 keV

The French Institute for Radioprotection and Nuclear Safety (IRSN), associated to the French Metrology Institute (LNE), is developing a time projection chamber using a Micromegas anode: μ-TPC. This work is carried out in collaboration with the Laboratory of Subatomic Physics and Cosmology (LPSC). The aim is to characterize with a primary procedure the energy distribution of neutron fluence in the energy range 8 keV - 1 MeV. The time projection chambers are gaseous detectors, which are able to measure charged particles energy and to reconstruct their track if a pixelated anode is used. In our case, the gas is used as a (n, p) converter in order to detect neutrons down to few keV. Coming from elastic collisions with neutrons, recoil protons lose a part of their kinetic energy by ionizing the gas. The ionization electrons are drifted toward a pixelated anode (2D projection), read at 50 MHz by a self-triggered electronic system to obtain the third track dimension. The neutron energy is reconstructed event by event thanks to proton scattering angle and proton energy measurements. The scattering angle is deduced from the 3D track. The proton energy is obtained by charge collection measurements, knowing the ionization quenching factor (i.e. the part of proton kinetic energy lost by ionizing the gas). The fluence is calculated thanks to the detected events number and the simulated detector response. The μ-TPC is a new reliable detector which enables to measure energy distribution of the neutron fluence without deconvolution or neutron calibration contrary to usual gaseous counters. The μ-TPC is still being developed and measurements have been carried out at the AMANDE facility, with neutrons energies going from 8 keV to 565 keV. After the context and the μ-TPC working principle presentation, measurements of the neutron energy and fluence at 27.2 keV, 144 keV and 565 keV are shown and compared to the complete detector simulation. This work shows the first direct reconstruction of neutron energy and fluence, simultaneously, at 27.2 keV in a continuous irradiation mode. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Implosion dynamics of condensed Z-pinch at the Angara-5-1 facility

The implosion dynamics of a condensed Z-pinch at load currents of up to 3.5 MA and a current rise time of 100 ns was studied experimentally at the Angara-5-1 facility. To increase the energy density, 1- to 3-mm-diameter cylinders made of a deuterated polyethylene−agar-agar mixture or microporous deuterated polyethylene with a mass density of 0.03–0.5 g/cm{sup 3} were installed in the central region of the loads. The plasma spatiotemporal characteristics were studied using the diagnostic complex of the Angara-5-1 facility, including electron-optical streak and frame imaging, time-integrated X-ray imaging, soft X-ray (SXR) measurements, and vacuum UV spectroscopy. Most information on the plasma dynamics was obtained using a ten-frame X-ray camera (Е > 100 eV) with an exposure of 4 ns. SXR pulses were recorded using photoemissive vacuum X-ray detectors. The energy characteristics of neutron emission were measured using the time-offlight method with the help of scintillation detectors arranged along and across the pinch axis. The neutron yield was measured by activation detectors. The experimental results indicate that the plasma dynamics depends weakly on the load density. As a rule, two stages of plasma implosion were observed. The formation of hot plasma spots in the initial stage of plasma expansion from the pinch axis was accompanied by short pulses of SXR and neutron emission. The neutron yield reached (0.4–3) × 10{sup 10} neutrons/shot and was almost independent of the load density due to specific features of Z-pinch dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SIMULATION OF RADIATION BACKGROUNDS ASSOCIATED WITH NUCLEAR DIAGNOSTICS IN THE NATIONAL IGNITION FACILITY

Experiments resulting in a significant neutron yield are scheduled to start in 2010 at the National Ignition Facility (NIF). Several experiments utilizing Tritium-Hydrogen-Deuterium (THD) and Deuterium-Tritium (DT) targets are scheduled as part of the National Ignition Campaign (NIC). A wide range of diagnostics will be used to measure several parameters of implosion such as the core and fuel shape, temperatures and densities, and neutron yield. Accurate evaluations of the neutron and gamma backgrounds are important for several diagnostics, such as the High Energy X-ray Imager (HEXRI) and Neutron-Time-Of-Flight (nTOF). Several sources of neutron and gamma backgrounds will impact the accuracy of the diagnostics measurements. Fusion neutrons generated by fuel burn and secondary neutrons resulting from the fusion neutrons interaction with structures present inside and outside the Target Chamber (TC) contribute to the neutron background. In the meantime, X-rays emitted from the implosion, X-rays resulting from Laser Plasma Interaction (LPI) of NIF beams with the hohlraum, and gamma-rays induced by neutron interactions with different structures inside and outside the TC contribute to the gamma background. A detailed model has been developed of the NIF facility and all structures inside the TC. Several Monte-Carlo simulations were performed to identify the expected signal-to- background ratios at several potential locations for the HEXRI and nTOF diagnostics. Gamma backgrounds associated with HEXRI were significantly reduced by using a tungsten collimator. The collimator resulted in the reduction of the gamma background at the HEXRI scintillator by more than an order of magnitude during the first 40 ns following a THD shot. The nTOF20 detectors inside the Neutron Spectrometry room are exposed to low levels of neutron and gamma background during yield shots.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Fast neutron-gamma discrimination on neutron emission profile measurement on JT-60U

A digital signal processing (DSP) system is applied to stilbene scintillation detectors of the multichannel neutron emission profile monitor in JT-60U. Automatic analysis of the neutron-{gamma} pulse shape discrimination is a key issue to diminish the processing time in the DSP system, and it has been applied using the two-dimensional (2D) map. Linear discriminant function is used to determine the dividing line between neutron events and {gamma}-ray events on a 2D map. In order to verify the validity of the dividing line determination, the pulse shape discrimination quality is evaluated. As a result, the {gamma}-ray contamination in most of the beam heating phase was negligible compared with the statistical error with 10 ms time resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗