Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Networked Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Fluvial Drainage Basins and Valley Networks: Eastern Margaritifer Sinus, Mars

The fluvial drainage of the eastern Margaritifer Sinus (MC-19NE, SE) and northeastern Argyre (MC-26NE) Quadrangles is dominated by two major longitudinal valley networks, the Parana/Loire system on the east, and the Samara Himera system to the west. It is believed that both of these drainages are through-going to the northwest and debouch into Margaritifer Chaos (general location: 12S, 22.5W). The Parana/Loire drainage is bounded on the east in part by an ancient multi-ringed impact basin. The Parana multi-digitate network drains northwest into a depositional basin, and impact basin floor, characterized by positive relief chaos. It is believed that Loire Vallis heads in the basin; thus Parana and Loire Valles may be treated as one system. Samara Valles heads in the northeastern Argyre Quadrangle and extends as a major truck valley to the northwest. Samara Valles cuts through the hills forming one of the concentric rings of the Ladon impact basin and joins the Himera drainage to trend in a more northerly direction to Margaritifer Chaos. The downstream portion of Himera is considered to be part of the Samara

Boothroyd, J. C.↗

Two-Dimensional Network Flow Modeling of No-Vent Tank Filling of A Cryogenic Tank With Thermo-Dynamic Vent System Assisted Injector

A finite volume-based network flow modeling tool, Generalized Fluid System Simulation Program (GFSSP), was used to simulate the no-vent filling of a cryogenic tank with a thermodynamic vent system assisted injector. The tank was discretized into nodes in the radial and axial directions to calculate two-dimensional axisymmetric flow with heat transfer between the solid wall and fluid. The nodes are connected by branches where momentum equations are solved to calculate the flowrates. The mass and energy conservation equations and the equation of state are solved to calculate pressure, temperature, and resident mass at the nodes. The energy conservation equations at the solid nodes were solved to calculate the temperature of the solid wall. The system of equations was solved by a combination of successive substitution and simultaneous Newton-Raphson method. The numerical model accounts for a) different regimes of pool boiling heat transfer, b) condensation of vapor around the spray droplets, c) condensation of vapor at the interface of the cooled injector and ullage, and d) condensation at the liquid-vapor interphase. The numerical predictions of tank pressure, filling rate, and wall temperatures were compared with the test data. The paper also presents the effect of nodal discretization by comparing the results of the 1D and 2D models and examines the effect of the droplet diameter on tank filling.

Nodal Model↗

Two-Dimensional Network Flow Modeling of No-Vent Tank Filling of A Cryogenic Tank With Thermo-Dynamic Vent System Assisted Injector

A finite volume-based network flow modeling tool, Generalized Fluid System Simulation Program (GFSSP), was used to simulate the no-vent filling of a cryogenic tank with a thermodynamic vent system assisted injector. The tank was discretized into nodes in the radial and axial directions to calculate two-dimensional axisymmetric flow with heat transfer between the solid wall and fluid. The nodes are connected by branches where momentum equations are solved to calculate the flowrates. The mass and energy conservation equations and the equation of state are solved to calculate pressure, temperature, and resident mass at the nodes. The energy conservation equations at the solid nodes were solved to calculate the temperature of the solid wall. The system of equations was solved by a combination of successive substitution and simultaneous Newton-Raphson method. The numerical model accounts for a) different regimes of pool boiling heat transfer, b) condensation of vapor around the spray droplets, c) condensation of vapor at the interface of the cooled injector and ullage, and d) condensation at the liquid-vapor interphase. The numerical predictions of tank pressure, filling rate, and wall temperatures were compared with the test data. The paper also presents the effect of nodal discretization by comparing the results of the 1D and 2D models and examines the effect of the droplet diameter on tank filling.

Nodal Model↗

Upgrade of the Thermal Vacuum Data System at NASA/GSFC

The Goddard Space Flight Center's new thermal vacuum data acquisition system is a networked client-sever application that enables lab operations crews to monitor all tests from a central location. The GSFC thermal vacuum lab consists of eleven chambers in Building 7 and one chamber in Building 10. The new data system was implemented for several reasons. These included the need for centralized data collection, more flexible and easier to use operator interface, greater data accessibility, a reduction in testing time and cost, and increased payload and personnel safety. Additionally, a new data system was needed for year-2000 compliance. This paper discusses the incorporation of the Thermal Vacuum Data System (TVDS) within the thermal vacuum lab at GSFC, its features and capabilities and lessons learned in its implementation. Additional topics include off-center (Internet) capability for remote monitoring and the role of TVDS in the efforts to automate thermal vacuum chamber operations.

Palmer, John↗

Upgrade of The Thermal Vacuum Data System at NASA/GSFC

The Goddard Space Flight Center's new thermal vacuum data acquisition system is a networked client-sever application that enables lab operations crews to monitor all tests from a central location. The GSFC thermal vacuum lab consists of eleven chambers in Building 7 and one chamber in Building 10. The new data system was implemented for several reasons. These included the need for centralized data collection, more flexible and easier to use operator interface, greater data accessibility, a reduction in testing time and cost, and increased payload and personnel safety. Additionally, a new data system was needed for year-2000 compliance. This paper discusses the incorporation of the Thermal Vacuum Data System (TVDS) within the thermal vacuum lab at GSFC, its features and capabilities and lessons learned in its implementation. Additional topics include off-center (Internet) capability for remote monitoring and the role of TVDS in the efforts to automate thermal vacuum chamber operations.

Palmer, John↗

A Mixed integer linear programming‐based distributed energy management for networked microgrids considering network operational objectives and constraints

Abstract Mixed integer linear programming (MILP)–based distributed energy management for networked microgrids embedded modern distribution systems is proposed. Considering the diverse ownership of microgrids, distributed energy resources (DERs) that interface directly with utilities and responsive loads, an alternating direction method of multipliers–based distributed framework was formulated for the scheduling of networked microgrids embedded modern distribution systems by adjusting nodal price signals iteratively. In addition, to make the formulated optimization problems resolvable through more accessible and popular MILP solvers, different linearisation techniques were employed to transform the nonlinear terms into linear or mixed integer linear formats. The proposed MILP‐based distributed method preserves all participants' autonomy (e.g., microgrids, DERs that interface directly with utilities and responsive loads), while incentivising them to actively participate in the distribution system operation with price signals. The proposed method is validated with results of numerical simulation using a modern distribution system consisting of multiple networked microgrids, DERs that interface directly with utilities, as well as responsive loads.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Image and Video Compression with VLSI Neural Networks

An advanced motion-compensated predictive video compression system based on artificial neural networks has been developed to effectively eliminate the temporal and spatial redundancy of video image sequences and thus reduce the bandwidth and storage required for the transmission and recording of the video signal. The VLSI neuroprocessor for high-speed high-ratio image compression based upon a self-organization network and the conventional algorithm for vector quantization are compared. The proposed method is quite efficient and can achieve near-optimal results.

compression artificial neural networks VLSI↗

C3 System Performance Simulation and User Manual. Getting Started: Guidelines for Users

This document is a User's Manual describing the C3 Simulation capabilities. The subject work was designed to simulate the communications involved in the flight of a Remotely Operated Aircraft (ROA) using the Opnet software. Opnet provides a comprehensive development environment supporting the modeling of communication networks and distributed systems. It has tools for model design, simulation, data collection, and data analysis. Opnet models are hierarchical -- consisting of a project which contains node models which in turn contain process models. Nodes can be fixed, mobile, or satellite. Links between nodes can be physical or wireless. Communications are packet based. The model is very generic in its current form. Attributes such as frequency and bandwidth can easily be modified to better reflect a specific platform. The model is not fully developed at this stage -- there are still more enhancements to be added. Current issues are documented throughout this guide.

Source record↗

Measurements of complex permittivity of microwave substrates in the 20 to 300 K temperature range from 26.5 to 40.0 GHz

A knowledge of the dielectric properties of microwave substrates at low temperatures is useful in the design of superconducting microwave circuits. Results are reported for a study of the complex permittivity of sapphire (Al2O3), magnesium oxide (MgO), silicon oxide (SiO2), lanthanum aluminate (LaAlO3), and zirconium oxide (ZrO2), in the 20 to 300 Kelvin temperature range, at frequencies from 26.5 to 40.0 GHz. The values of the real and imaginary parts of the complex permittivity were obtained from the scattering parameters, which were measured using a HP-8510 automatic network analyzer. For these measurements, the samples were mounted on the cold head of a helium gas closed cycle refrigerator, in a specially designed vacuum chamber. An arrangement of wave guides, with mica windows, was used to connect the cooling system to the network analyzer. A decrease in the value of the real part of the complex permittivity of these substrates, with decreasing temperature, was observed. For MgO and Al2O3, the decrease from room temperature to 20 K was of 7 and 15 percent, respectively. For LaAlO3, it decreased by 14 percent, for ZrO2 by 15 percent, and for SiO2 by 2 percent, in the above mentioned temperature range.

Miranda, Felix A.↗

Measurements of complex permittivity of microwave substrates in the 20 to 300 K temperature range from 26.5 to 40.0 GHz

A knowledge of the dielectric properties of microwve substrates at low temperatures is useful in the design of superconducting microwave circuits. Results are reported for a study of the complex permittivity of sapphire (Al2O3), magnesium oxide (MgO), silicon oxide (SiO2), lanthanum aluminate (LaAlO3), and zirconium oxide (ZrO2), in the 20 to 300 Kelvin temperature range, at frequencies from 26.5 to 40.0 GHz. The values of the real and imaginary parts of the complex permittivity were obtained from the scattering parameters, which were measured using an HP-8510 automatic network analyzer. For these measurements, the samples were mounted on the cold head of a helium gas closed cycle refrigerator, in a specially designated vacuum chamber. An arrangement of wave guides, with mica windows, was used to connect the cooling system to the network analyzer. A decrease in the value of the real part of the complex permittivity of these substrates, with decreasing temperature, was observed. For MgO and Al2O3, the decrease from room temperature to 20 K was of 7 and 15 percent, respectively. For LaAlO3, it decreased by 14 percent, for ZrO2 by 15 percent, and for SiO2 by 2 percent, in the above mentioned temperature range.

Miranda, Felix A.↗

Description of real-time Ada software implementation of a power system monitor for the Space Station Freedom PMAD DC testbed

The authors describe the Ada language software developed to perform the electrical power system monitoring functions for the NASA Lewis Research Center's Power Management and Distribution (PMAD) DC testbed. The results of the effort to implement this monitor are presented. The PMAD DC testbed is a reduced-scale prototype of the electric power system to be used in Space Station Freedom. The power is controlled by smart switches known as power control components (or switchgear). The power control components are currently coordinated by five Compaq 386/20e computers connected through an 802.4 local area network. The power system monitor algorithm comprises several functions, including periodic data acquisition, data smoothing, system performance analysis, and status reporting. Data are collected from the switchgear sensors every 100 ms, then passed through a 2-Hz digital filter. System performance analysis includes power interruption and overcurrent detection. The system monitor required a hardware timer interrupt to activate the data acquisition function. The execution time of the code was optimized by using an assembly language routine. The routine allows direct vectoring of the processor to Ada language procedures that perform periodic control activities.

Ludwig, Kimberly↗

Assessment of the High Flux Isotope Reactor Cybersecurity Initiative

Recent cyber-attacks on industrial control systems, and inadvertent exposure of nuclear plant systems to cyber-exploits underscore the need for plant operators to adopt and deploy cyber-security defense solutions made for industrial control systems. Of increasing concern is the fact that international cyber hackers are beginning to target critical infrastructure, and because these more modern controls systems depend on advanced use of digital systems, they are more vulnerable than ever before to cyber-attacks. Traditional cyber defense strategies and products that have been available for decades are tailored for use on IT or corporate networks but can cause interruptions and catastrophic damage when deployed on industrial control system networks. The Department of Energy (DOE) Office of Nuclear Energy established the Gateway for Accelerated Innovation in Nuclear (GAIN) program to provide private companies pursuing innovative nuclear energy technologies with access to the technical support necessary to move toward commercialization. One of these GAIN small business vouchers was awarded to Dragos, Inc. to enable collaboration with Oak Ridge National Laboratory (ORNL) to evaluate the Dragos Platform on a production nuclear reactor test bed, hence laying the path for future commercial adoption. The vision was to provide a guide for industrial operators on implementing an industrial monitoring solution and to show how these solutions can be deployed without causing safety and reliability issues. This report documents the results of the collaboration between ORNL and Dragos, Inc.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Data communications and monitor for the Penn State University profiler network

The profiler network installed by the Department of Meteorology at Penn State University utilizes a microcomputer for network monitoring and control. The network consists of two VHF and one UHF wind profiling Doppler radars. Additional measurement systems added to the network include temperature and humidity profiling radiometers, sodar for boundary layer wind profiling and selected surface based baseline systems. Remote diagnostic capabilities were also implemented in the Penn State network. It is possible to remotely analyze many specific malfunctions of the transmitter or signal processor.

Peters, R. M.↗

Fuzzy logic applications to expert systems and control

A considerable amount of work on the development of fuzzy logic algorithms and application to space related control problems has been done at the Johnson Space Center (JSC) over the past few years. Particularly, guidance control systems for space vehicles during proximity operations, learning systems utilizing neural networks, control of data processing during rendezvous navigation, collision avoidance algorithms, camera tracking controllers, and tether controllers have been developed utilizing fuzzy logic technology. Several other areas in which fuzzy sets and related concepts are being considered at JSC are diagnostic systems, control of robot arms, pattern recognition, and image processing. It has become evident, based on the commercial applications of fuzzy technology in Japan and China during the last few years, that this technology should be exploited by the government as well as private industry for energy savings.

Lea, Robert N.↗