Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NIR”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Two-Photon Flow Cytometry

Flow cytometry is a powerful technique for obtaining quantitative information from fluorescence in cells. Quantitation is achieved by assuring a high degree of uniformity in the optical excitation and detection, generally by using a highly controlled flow such as is obtained via hydrodynamic focusing. In this work, we demonstrate a two-beam, two- channel detection and two-photon excitation flow cytometry (T(sup 3)FC) system that enables multi-dye analysis to be performed very simply, with greatly relaxed requirements on the fluid flow. Two-photon excitation using a femtosecond near-infrared (NIR) laser has the advantages that it enables simultaneous excitation of multiple dyes and achieves very high signal-to-noise ratio through simplified filtering and fluorescence background reduction. By matching the excitation volume to the size of a cell, single-cell detection is ensured. Labeling of cells by targeted nanoparticles with multiple fluorophores enables normalization of the fluorescence signal and thus ratiometric measurements under nonuniform excitation. Quantitative size measurements can also be done even under conditions of nonuniform flow via a two-beam layout. This innovative detection scheme not only considerably simplifies the fluid flow system and the excitation and collection optics, it opens the way to quantitative cytometry in simple and compact microfluidics systems, or in vivo. Real-time detection of fluorescent microbeads in the vasculature of mouse ear demonstrates the ability to do flow cytometry in vivo. The conditions required to perform quantitative in vivo cytometry on labeled cells will be presented.

Zhog, Cheng Frank↗

Ischemia causes muscle fatigue

The purpose of this investigation was to determine whether ischemia, which reduces oxygenation in the extensor carpi radialis (ECR) muscle, causes a reduction in muscle force production. In eight subjects, muscle oxygenation (TO2) of the right ECR was measured noninvasively and continuously using near infrared spectroscopy (NIRS) while muscle twitch force was elicited by transcutaneous electrical stimulation (1 Hz, 0.1 ms). Baseline measurements of blood volume, muscle oxygenation and twitch force were recorded continuously, then a tourniquet on the upper arm was inflated to one of five different pressure levels: 20, 40, 60 mm Hg (randomized order) and diastolic (69 +/- 9.8 mm Hg) and systolic (106 +/- 12.8 mm Hg) blood pressures. Each pressure level was maintained for 3-5 min, and was followed by a recovery period sufficient to allow measurements to return to baseline. For each respective tourniquet pressure level, mean TO2 decreased from resting baseline (100% TO2) to 99 +/- 1.2% (SEM), 96 +/- 1.9%, 93 +/- 2.8%, 90 +/- 2.5%, and 86 +/- 2.7%, and mean twitch force decreased from resting baseline (100% force) to 99 +/- 0.7% (SEM), 96 +/- 2.7%, 93 +/- 3.1%, 88 +/- 3.2%, and 86 +/- 2.6%. Muscle oxygenation and twitch force at 60 mm Hg tourniquet compression and above were significantly lower (P < 0.05) than baseline value. Reduced twitch force was correlated in a dose-dependent manner with reduced muscle oxygenation (r = 0.78, P < 0.001). Although the correlation does not prove causation, the results indicate that ischemia leading to a 7% or greater reduction in muscle oxygenation causes decreased muscle force production in the forearm extensor muscle. Thus, ischemia associated with a modest decline in TO2 causes muscle fatigue.

Non-NASA Center↗

Clear-Sky Narrowband Albedo Variations Derived from VIRS and MODIS Data

A critical parameter for detecting clouds and aerosols and for retrieving their microphysical properties is the clear-sky radiance. The Clouds and the Earth's Radiant Energy System (CERES) Project uses the visible (VIS; 0.63 m) and near-infrared (NIR; 1.6 or 2.13 m) channels available on same satellites as the CERES scanners. Another channel often used for cloud and aerosol, and vegetation cover retrievals is the vegetation (VEG; 0.86- m) channel that has been available on the Advanced Very High Resolution Radiometer (AVHRR) for many years. Generally, clear-sky albedo for a given surface type is determined for conditions when the vegetation is either thriving or dormant and free of snow. Snow albedo is typically estimated without considering the underlying surface type. The albedo for a surface blanketed by snow, however, should vary with surface type because the vegetation often emerges from the snow to varying degrees depending on the vertical dimensions of the vegetation. For example, a snowcovered prairie will probably be brighter than a snowcovered forest because the snow typically falls off the trees exposing the darker surfaces while the snow on a grassland at the same temperatures will likely be continuous and, therefore, more reflective. Accounting for the vegetation-induced differences should improve the capabilities for distinguishing snow and clouds over different surface types and facilitate improvements in the accuracy of radiative transfer calculations between the snow-covered surface and the atmosphere, eventually leading to improvements in models of the energy budgets over land. This paper presents a more complete analysis of the CERES spectral clear-sky reflectances to determine the variations in clear-sky top-of-atmosphere (TOA) albedos for both snow-free and snow-covered surfaces for four spectral channels using data from Terra and Aqua.. The results should be valuable for improved cloud retrievals and for modeling radiation fields.

Sun-Mack, Sunny↗

An Overview of Lunar Calibration and Characterization for the EOS Terra and Aqua MODIS

The Moon can be used as a stable source for Earth-observing sensors on-orbit radiometric and spatial stability monitoring in the VIS and NIR spectral regions. It can also serve as a calibration transfer vehicle among multiple sensors. Nearly identical copies of the Moderate Resolution Imaging Spectroradiometer (MODE) have been operating on-board the NASA's Earth Observing System (EOS) Terra and Aqua satellites since their launches in December 1999 and May 2002, respectively. Terra and Aqua MODIS each make observations in 36 spectral bands covering the spectral range from 0.41 to 14.5 microns and are calibrated on-orbit by a set of on-board calibrations (OBCs) including: 1) a solar diffuser (SD), 2) a solar diffuser stability monitor (SDSM), 3) a blackbody (BB), and 4) a spectro-radiometric calibration assembly (SRCA). In addition to fully utilizing the OBCs, the Moon has been used extensively by both Terra and Aqua MODIS to support their on-orbit calibration and characterization. A 4 This paper provides an overview of applications of lunar calibration and characterization from the MODIS perspective, including monitoring radiometric calibration stability for the reflective solar bands (RSBs), tracking changes of the sensors response versus scan-angle (RVS), examining the sensors spatial performance , and characterizing optical leaks and electronic crosstalk among different spectral bands and detectors. On-orbit calibration consistency between the two MODIS instruments is also addressed. Based on the existing on-orbit time series of the Terra and Aqua MODIS lunar observations, the radiometric difference between the two sensors is less than +/-1% for the RSBs. This method provides a powerful means of performing calibration comparisons among Earth-observing sensors and assures consistent data and science products for the long-term studies of climate and environmental changes.

Xiong, X.↗

Autonomous In-Situ Resources Prospector

This presentation will describe the concept of an autonomous, intelligent, rover-based rapid surveying system to identify and map several key lunar resources to optimize their ISRU (In Situ Resource Utilization) extraction potential. Prior to an extraction phase for any target resource, ground-based surveys are needed to provide confirmation of remote observation, to quantify and map their 3-D distribution, and to locate optimal extraction sites (e.g. ore bodies) with precision to maximize their economic benefit. The system will search for and quantify optimal minerals for oxygen production feedstock, water ice, and high glass-content regolith that can be used for building materials. These are targeted because of their utility and because they are, or are likely to be, variable in quantity over spatial scales accessible to a rover (i.e., few km). Oxygen has benefits for life support systems and as an oxidizer for propellants. Water is a key resource for sustainable exploration, with utility for life support, propellants, and other industrial processes. High glass-content regolith has utility as a feedstock for building materials as it readily sinters upon heating into a cohesive matrix more readily than other regolith materials or crystalline basalts. Lunar glasses are also a potential feedstock for oxygen production, as many are rich in iron and titanium oxides that are optimal for oxygen extraction. To accomplish this task, a system of sensors and decision-making algorithms for an autonomous prospecting rover is described. One set of sensors will be located in the wheel tread of the robotic search vehicle providing contact sensor data on regolith composition. Another set of instruments will be housed on the platform of the rover, including VIS-NIR imagers and spectrometers, both for far-field context and near-field characterization of the regolith in the immediate vicinity of the rover. Also included in the sensor suite are a neutron spectrometer, ground-penetrating radar, and an instrumented cone penetrometer for subsurface assessment. Output from these sensors will be evaluated autonomously in real-time by decision-making software to evaluate if any of the targeted resources has been detected, and if so, to quantify their abundance. Algorithms for optimizing the mapping strategy based on target resource abundance and distribution are also included in the autonomous software. This approach emphasizes on-the-fly survey measurements to enable efficient and rapid prospecting of large areas, which will improve the economics of ISRU system approaches. The mature technology will enable autonomous rovers to create in-situ resource maps of lunar or other planetary surfaces, which will facilitate human and robotic exploration.

Dissly, R. W.↗

Atmospheric Correction of High-Spatial-Resolution Commercial Satellite Imagery Products Using MODIS Atmospheric Products

Remotely sensed ground reflectance is the foundation of any interoperability or change detection technique. Satellite intercomparisons and accurate vegetation indices, such as the Normalized Difference Vegetation Index (NDVI), require the generation of accurate reflectance maps (NDVI is used to describe or infer a wide variety of biophysical parameters and is defined in terms of near-infrared (NIR) and red band reflectances). Accurate reflectance-map generation from satellite imagery relies on the removal of solar and satellite geometry and of atmospheric effects and is generally referred to as atmospheric correction. Atmospheric correction of remotely sensed imagery to ground reflectance has been widely applied to a few systems only. The ability to obtain atmospherically corrected imagery and products from various satellites is essential to enable widescale use of remotely sensed, multitemporal imagery for a variety of applications. An atmospheric correction approach derived from the Moderate Resolution Imaging Spectroradiometer (MODIS) that can be applied to high-spatial-resolution satellite imagery under many conditions was evaluated to demonstrate a reliable, effective reflectance map generation method. Additional information is included in the original extended abstract.

Pagnutti, Mary↗

Space radiation transport properties of polyethylene-based composites

Composite materials that can serve as both effective shielding materials against cosmic-ray and energetic solar particles in deep space, as well as structural materials for habitat and spacecraft, remain a critical and mission enabling component in mission planning and exploration. Polyethylene is known to have excellent shielding properties due to its low density, coupled with high hydrogen content. Polyethylene-fiber reinforced composites promise to combine this shielding effectiveness with the required mechanical properties of structural materials. Samples of polyethylene-fiber reinforced epoxy matrix composite 1-5 cm thick were prepared at the NASA Marshall Space Flight Center and tested against a 500 MeV/nucleon Fe beam at the HIMAC facility of NIRS in Chiba, Japan. This paper presents measured and calculated results for the radiation transport properties of these samples.

Polyethylene/chemistry↗

Environmental impact analysis with the airspace concept evaluation system

The National Aeronautics and Space Administration (NASA) Ames Research Center has developed the Airspace Concept Evaluation System (ACES), which is a fast-time simulation tool for evaluating Air Traffic Management (ATM) systems. This paper describes linking a capability to ACES which can analyze the environmental impact of proposed future ATM systems. This provides the ability to quickly evaluate metrics associated with environmental impacts of aviation for inclusion in multi-dimensional cost-benefit analysis of concepts for evolution of the National Airspace System (NAS) over the next several decades. The methodology used here may be summarized as follows: 1) Standard Federal Aviation Administration (FAA) noise and emissions-inventory models, the Noise Impact Routing System (NIRS) and the Emissions and Dispersion Modeling System (EDMS), respectively, are linked to ACES simulation outputs; 2) appropriate modifications are made to ACES outputs to incorporate all information needed by the environmental models (e.g., specific airframe and engine data); 3) noise and emissions calculations are performed for all traffic and airports in the study area for each of several scenarios, as simulated by ACES; and 4) impacts of future scenarios are compared to the current NAS baseline scenario. This paper also provides the results of initial end-to-end, proof-of-concept runs of the integrated ACES and environmental-modeling capability. These preliminary results demonstrate that if no growth is likely to be impeded by significant environmental impacts that could negatively affect communities throughout the nation.

Augustine, Stephen↗

Spectroscopy of Jet-Cooled Neutral and Ionized PAHs: Implications for Interstellar Dust

We present the gas-phase spectroscopy of neutral and ionized polycyclic aromatic hydrocarbons (PAHs) measured in the W-Visible-NIR range in an astrophysically relevant environment. These measurements provide data on PAHs and nanometer sized particles that can now be directly compared to astronomical observations. The harsh physical conditions of the IS medium - characterized by a low temperature, an absence of collisions and strong VUV radiation fields - are simulated in the laborat'ory by associating a molecular beam with an ionizing discharge to generate a cold plasma expansion. PAH ions are formed from the neutral precursors in an isolated environment at low temperature ($\sim lOO$-K). The spectra of neutral and ionized PAHs are measured using the high sensitivity methods of cavity ring down spectroscopy (CRDS) and multiplex integrated cavity output spectroscopy (MICOS). These experiments provide unique information on the spectra of free, cold large carbon molecules and ions in the gas phase. The electronic bands measured for ionized PAH are found to be intrinsically broad ($\geq$20 cm$^{-l}$) while the bands associated with the neutral precursors are narrower (of the order of 2 - 10 cm$^{-l}$). The laboratory data are discussed and compared with recent astronomical spectra of large and narrow DIBs and with the spectra of circumstellar environments of selected carbon stars (see contribution of Cami et al.) and the implications for the interstellar PAH population are derived. Preliminary results also show that carbon nanoparticles are formed during the short residence time of the precursors in the plasma. This finding holds great potential for understanding the formation process of interstellar grains.

Salama, F.↗

Novel Biomedical Device Utilizing Light-Emitting Nanostructures Developed

Sketches and chemical diagrams of state-of-the-art device and novel proposed device are presented. Current device uses a diode laser that emits into a fluorescent fluid only one wavelength and a photodetector diode that detects only one wavelength. Only one type of bacteria can be detected. The proposed device uses a quantum dot array that emits into a fluorescent fluid multiple wavelengths and an NIR 512 spectrometer that scans 0.8- to 1.7-mm wavelengths. Hundreds of different bacteria and viruses can be detected. A novel biomedical device is being developed at the NASA Glenn Research Center in cooperation with the University of Michigan. This device uses nano-structured quantum dots that emit light in the near-infrared (IR) region. The nanostructured quantum dots are used as a source and excite fluorochrome polymers coupled with antibodies that seek out and attach to specific bacteria and viruses. The fluorochrome polymers/antibodies fluoresce at specific wavelengths in the near-IR spectrum, but these wavelengths are offset from the excitation wavelength and can be detected with a tunable spectrometer. The device will be used to detect the presence of viruses and bacteria in simple fluids and eventually in more complex fluids, such as blood. Current state-of-the-art devices are limited to single bacteria or virus detection and a considerable amount of time and effort is required to prepare samples for analysis. Most importantly, the devices are quite large and cumbersome, which prohibits them from being used on the International Space Station and the space shuttles. This novel device uses nanostructured quantum dots which, through molecular beam epitaxy and highly selective annealing processes, can be developed into an illumination source that could potentially generate hundreds of specific wavelengths. As a result, this device will be able to excite hundreds of antibody/fluorochrome polymer combinations, which in turn could be used to detect hundreds of bacteria and viruses in fluids. A novel sample preparation technique that exploits micromembrane filtration and centrifugation methods has been developed for this device. The technique greatly reduces the time required to prepare the sample and the amount of sample needed to perform an accurate and comprehensive analysis. Last, and probably most important, because of the nano-light-emitting source and the novel sample preparation technique, the overall size of the device could be reduced dramatically. This device will serve as a nanoscale lab-on-a-chip for in situ microorganism detection and will enable tests to be performed on a time scale of minutes rather than days. Thus, it is ideally suited for monitoring the environmental conditions onboard the International Space Station and the space shuttles, thereby enhancing the safety of the astronauts. In addition, the device has important commercial applications, such as detecting the presence of bacteria and viruses in water at food- and beverage-processing centers, water treatment plants, and restaurants. Also, this technology has the potential to be used to detect bacteria and viruses in more complex fluids, such as blood--which in all likelihood would revolutionize blood analysis as it is performed today. This project was made possible through the Director's Discretionary Fund and is ongoing. In addition, this project provides funding to Dr. Rachel Goldman of the University of Michigan for the research and development of nanostructured quantum dots.

Scardelletti, Maximilian C.↗

The Swift Mission and the REM Telescope

Following a description of the science drive which originated the Swift Mission, this is US NASA MIDEX Mission with the collaboration of Italy and the UK, we will describe the status of the hardware and the observing strategy. The telemetry is carried out via the TDRSS satellite for those communications that need immediate response. The data transfer and the scheduled uploading of routine commands will be done through the ASI Malindi station in Kenia. Both in the US and in Europe a large effort will be done to follow the bursts with the maximum of efficiency and as soon as possible after the alert. We will describe how the ESO VLT telescopes are able to respond to the alert. To address the problematic of the dark bursts and to immediately follow up all of the bursts also in the Near Infrared we designed and built a 60 cm NIR Robotic telescope, REM, to be located on the ESO ground at Cerro La Silla. The instrumentation includes also a low dispersion spectrograph with the capability of multi wavelength optical photometry.

Gehrels, N.↗

Influence of a fat layer on the near infrared spectra of human muscle: quantitative analysis based on two-layered Monte Carlo simulations and phantom experiments

The influence of fat thickness on the diffuse reflectance spectra of muscle in the near infrared (NIR) region is studied by Monte Carlo simulations of a two-layer structure and with phantom experiments. A polynomial relationship was established between the fat thickness and the detected diffuse reflectance. The influence of a range of optical coefficients (absorption and reduced scattering) for fat and muscle over the known range of human physiological values was also investigated. Subject-to-subject variation in the fat optical coefficients and thickness can be ignored if the fat thickness is less than 5 mm. A method was proposed to correct the fat thickness influence. c2005 Optical Society of America.

NASA Discipline Life Sciences Technologies↗

Effects of heavy ion to the primary culture of mouse brain cells

To investigate effects of low dose heavy particle radiation to CNS system, we adopted mouse neonatal brain cells in culture being exposed to heavy ions by HIMAC at NIRS and NSRL at BNL. The applied dose varied from 0.05 Gy up to 2.0 Gy. The subsequent biological effects were evaluated by an induction of apoptosis and neuron survival focusing on the dependencies of the animal strains, SCID, B6, B6C3F1, C3H, used for brain cell culture, SCID was the most sensitive and C3H the least sensitive to particle radiation as evaluated by 10% apoptotic criterion. The LET dependency was compared with using SCID and B6 cells exposing to different ions (H, C, Ne, Si, Ar, and Fe). Although no detectable LET dependency was observed in the high LET (55-200 keV/micrometers) and low dose (<0.5 Gy) regions. The survivability profiles of the neurons were different in the mouse strains and ions. In this report, a result of memory and learning function to adult mice after whole-body and brain local irradiation at carbon ion and iron ion.

NASA Discipline Radiation Health↗

Recent Advances in Synthesis and Characterization of SWCNTs Produced by Laser Oven Process

Results from the parametric study of the two-laser oven process indicated possible improvements with flow conditions and laser characteristics. Higher flow rates, lower operating pressures coupled with changes in flow tube material are found to improve the nanotube yields. The collected nanotube material is analyzed using a combination of characterization techniques including SEM, TEM, TGA, Raman and UV-VIS-NIR to estimate the purity of the samples. In-situ diagnostics of the laser oven process is now extended to include the surface temperature of the target material. Spectral emission from the target surface is compared with black body type emission to estimate the temperature. The surface temperature seemed to correlate well with the ablation rate as well as the quality of the SWCNTs. Recent changes in improving the production rate by rastering the target and using cw laser will be presented.

Aepalli, Sivaram↗

Recent Advances in Synthesis and Characterization of SWCNTs produced by laser oven process

Results from the parametric study of the two-laser oven process indicated possible improvements with flow conditions and laser characteristics (ref. 1). Higher flow rates, lower operating pressures coupled with changes in flow tube material are found to improve the nanotube yields. The collected nanotube material is analyzed using a combination of characterization techniques including SEM, TEM, TGA, Raman and UV-VIS-NIR to estimate the purity of the samples. Insitu diagnostics of the laser oven process is now extended to include the surface temperature of the target material. Spectral emission from the target surface is compared with black body type emission to estimate the temperature. The surface temperature seemed to correlate well with the ablation rate as well as the quality of the SWCNTs. Recent changes in improving the production rate by rastering the target and using cw laser will be presented.

Arepalli, Sivaram↗

Emerging Techniques for Vicarious Calibration of Visible Through Short Wave Infrared Remote Sensing Systems

Simple field-portable white light LED calibration source shows promise for visible range (420-750 nm) 1) Prototype demonstrated <0.5% drift over 10-40 C temperature range; 2) Additional complexity (more LEDs) will be necessary for extending spectral range into the NIR and SWIR; 3) LED long lifetimes should produce at least several hundreds of hours or more stability, minimizing need for expensive calibrations and supporting long-duration field campaigns; and 4) Enabling technology for developing autonomous sites.

Ryan, Robert E.↗

Nanotube Activities at NASA-Johnson Space Center

Nanotube activities at NASA-Johnson Space Center include production, purification, characterization as well as applications of single wall carbon nanotubes (SWCNTs). A parametric study of the pulsed laser ablation process is recently completed to monitor the effect of production parameters including temperature, buffer gas, flow rate, pressure, and laser fluence. Enhancement of production is achieved by rastering the graphite target and by increasing the target surface temperature with a cw laser. In-situ diagnostics during production included time resolved passive emission and laser induced fluorescence from the plume. The improvement of the purity by a variety of steps in the purification process is monitored by characterization techniques including SEM, TEM, Raman, UV-VIS-NIR and TGA. A recently established NASA-JSC protocol for SWCNT characterization is undergoing revision with feedback from nanotube community. Efforts at JSC over the past five years in composites have centered on structural polymer/nanotube systems. Recent activities broadened this focus to multifunctional materials, supercapacitors, fuel cells, regenerable CO2 absorbers, electromagnetic shielding, radiation dosimetry and thermal management systems of interest for human space flight. Preliminary tests indicate improvement of performance in most of these applications because of the large Surface area as well as high electrical and thermal conductivity exhibited by SWCNTs. Comparison with existing technologies and possible future improvements in the SWCNT materials sill be presented.

Arepalli, Sivaram↗

(abstract) Constraints on the Venus Deep Atmosphere Composition from Near Infrared Observations of the Night Side

Spatially resolved NIR images and spectra of Venus obtained in 1983 revealed high-contrast emission features on the night side of the planet at wavelengths near 1.74 and 2.3 (micro)m. Subsequent observational and modeling studies confirmed that this radiation originates as thermal emission from the hot lower atmosphere (25-40 km).

Venus water vapor near infrared sulfuric acid surf↗