Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement error”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Heterogeneous Distribution of Chromium on Mercury

Measurements made with geochemical instruments on the MESSENGER spacecraft revealed that Mercury's crust is surprisingly rich in volatile elements, including S, Na, K, Cl, and C, and that it is enriched in Mg and depleted in Al, Ca, and Fe, relative to other terrestrial planets. Geochemical maps also indicated the presence of a number of distinct geochemical terranes. The MESSENGER X-ray Spectrometer (XRS) detected X-ray fluorescence, induced by incident solar X-rays, from the top approx. 10s of micrometers of Mercury's surface. Like Fe, Cr was only detectable by XRS during large solar flares. However, accurate Cr measurements are more susceptible to systematic errors than other elements measured by the XRS. Therefore, to date, Cr data have been published for only 11 XRS measurements, but we have recently derived a map of Cr/Si across Mercury's surface. This map is based on data acquired through the complete MESSENGER mission and reveals clear spatial heterogeneity in Cr.

Nittler, L. R.↗

Independent Calibration Approach for the CLARREO Pathfinder Mission

A CLARREO (Climate Absolute Radiance and Refractivity Observatory) Pathfinder (CPF) mission has been funded to demonstrate retrieval of SI-traceable spectral reflectance with absolute uncertainty <0.3% (k=1). The mission consists of a Reflected Solar spectrometer that will be hosted on the International Space Station (ISS) in the 2023 timeframe and rely on a ratioing radiometer approach to retrieve the unprecedented accuracy. Demonstrating that the accuracy is achieved through an Independent Calibration effort similar in philosophy to the efforts in metrology laboratories relying on multiple, independent measurements to improve credibility for a sensor’s absolute and relative uncertainty error budgets. These measurements use different traceability paths and multiple instrument approaches and CPF’s Independent Calibration will be similar in this regard. The Independent Calibration relies on a pre-launch absolute radiometric calibration obtained from additional testing done after instrument thermal-vacuum (TVAC) testing. The added radiometric calibration is combined with a high fidelity instrument model to provide an on-orbit radiometric calibration independent from the ratioing radiometer approach. The current work describes the post-TVAC testing portion of the CPF Independent Calibration Plan and the Independent Model Development as well as planned on-orbit Evaluation of the Independent Calibration.

CLARREO Pathfinder↗

Energy Performance Assessment of Radiant Cooling System through Modeling and Calibration at Component Level

The paper describes a case study of an information technology office building with a radiant cooling system and a conventional variable air volume (VAV) system installed side by side so that performancecan be compared. First, a 3D model of the building involving architecture, occupancy, and HVAC operation was developed in EnergyPlus, a simulation tool. Second, a different calibration methodology was applied to develop the base case for assessing the energy saving potential. This paper details the calibration of the whole building energy model to the component level, including lighting, equipment, and HVAC components such as chillers, pumps, cooling towers, fans, etc. Also a new methodology for the systematic selection of influence parameter has been developed for the calibration of a simulated model which requires large time for the execution. The error at the whole building level [measured in mean bias error (MBE)] is 0.2%, and the coefficient of variation of root mean square error (CvRMSE) is 3.2%. The total errors in HVAC at the hourly are MBE = 8.7% and CvRMSE = 23.9%, which meet the criteria of ASHRAE 14 (2002) for hourly calibration. Different suggestions have been pointed out to generalize the energy saving of radiant cooling system through the existing building system. So a base case model was developed by using the calibrated model for quantifying the energy saving potential of the radiant cooling system. It was found that a base case radiant cooling system integrated with DOAS can save 28% energy compared with the conventional VAV system.

Building Energy Simulation↗

An Introduction to the FCRD Transmutation Fuels Handbook 2015

Transmutation of minor actinides such as Np, Am, and Cm in spent nuclear fuel is of international interest because of its potential for reducing the long-term health and safety hazards caused by the radioactivity of the spent fuel. For this reason, the DOE Fuel Cycle Research and Development (FCRD) Advanced Fuels Campaign (AFC) has been performing research on nuclear fuel technologies that could be used in conjunction with a future actinide transmutation mission. One important approach to transmutation involves incorporating the minor actinides into U-Pu-Zr alloys, which can be used as fuel in fast reactors. It is, therefore, important to understand the properties of U-Pu-Zr alloys. The Idaho National Laboratory has recently published a handbook intended to summarize key properties of these alloys for researchers. This handbook focuses on phases and key thermophysical properties of elements and alloys in the U-Pu-Zr system. It is envisioned as the first of a series, which will serve as a summary of current knowledge about important properties of transmutation fuels. Future volumes will include information about properties and materials not covered in the first edition, as well as updates to information in this edition of the handbook. The handbook is intended to serve two audiences. One audience is researchers, who may find it useful to know what has been measured, where it has been published, and what kinds of information are needed. A second audience is modelers, who need a concise summary of information about specific properties and the accuracy with which they are known. The two audiences have different needs, and the handbook is a compromise intended to be useful to both. Therefore, it includes summaries of research results and needs, but generally does not present the original data. It also includes numerous graphs and, where available, equations that provide convenient approximations to materials properties for modelers. It is important to understand that most of the equations provided in this handbook are derived by fitting polynomials to data and have no physical basis; while they can be used with caution for design studies, fuel modelers will probably want to use the original experimental data to develop or validate their own equations and/or models. Although the handbook includes some citations to research involving development of models, its primary focus is experimental data. Many of the measurements of the U-Pu-Zr system were made before 1980. Where possible, the handbook relies on previous reviews of experimental data rather than presenting new interpretations of the old information. It is expected that researchers will refer to the original literature for details that are not presented in the handbook. Metals and alloys in the U-Pu-Zr system are uniquely difficult to study for a number of reasons. Experimental designs may need to be modified to allow researchers to work with these hazardous materials safely. Kinetics of phase transformations are commonly sluggish, and it is highly unlikely that all of the samples in previous research had equilibrium phases and microstructures. Thermal cycling effects (changes in sample characteristics that are not fully reversed during cooling) are commonly reported and may be significant. Careful control of impurities (particularly oxygen) during sample fabrication and data collection is both crucial and difficult, and concentrations below 100 ppm in samples may significantly affect thermophysical properties. For all of these reasons, differences between measured values for similar alloys are commonly far larger than the estimated errors for individual measurements. Further research on well-characterized materials with careful control of impurities is needed for all of the alloys discussed here. The 2015 FCRD Handbook summarizes currently available information about U, Pu, Zr, and their binary and ternary alloys. It contains information about phase diagrams and related information (including phases and phase transformations); heat capacity, entropy, and enthalpy; thermal expansion; and thermal conductivity and diffusivity. In addition to presenting information about materials properties, it attempts to provide information about how well the property is known and how much variation exists between measurements. Although the handbook includes some references to publications about modeling, its primary focus is experimental data. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Measured and predicted root-mean-square errors in square and triangular antenna mesh facets

Deflection shapes of square and equilateral triangular facets of two tricot-knit, gold plated molybdenum wire mesh antenna materials were measured and compared, on the basis of root mean square (rms) differences, with deflection shapes predicted by linear membrane theory, for several cases of biaxial mesh tension. The two mesh materials contained approximately 10 and 16 holes per linear inch, measured diagonally with respect to the course and wale directions. The deflection measurement system employed a non-contact eddy current proximity probe and an electromagnetic distance sensing probe in conjunction with a precision optical level. Despite experimental uncertainties, rms differences between measured and predicted deflection shapes suggest the following conclusions: that replacing flat antenna facets with facets conforming to parabolically curved structural members yields smaller rms surface error; that potential accuracy gains are greater for equilateral triangular facets than for square facets; and that linear membrane theory can be a useful tool in the design of tricot knit wire mesh antennas.

Fichter, W. B.↗

Assessment of Current Estimates of Global and Regional Mean Sea Level from the TOPEX/Poseidon, Jason-1, and OSTM 17-Year Record

The science value of satellite altimeter observations has grown dramatically over time as enabling models and technologies have increased the value of data acquired on both past and present missions. With the prospect of an observational time series extending into several decades from TOPEX/Poseidon through Jason-1 and the Ocean Surface Topography Mission (OSTM), and further in time with a future set of operational altimeters, researchers are pushing the bounds of current technology and modeling capability in order to monitor global sea level rate at an accuracy of a few tenths of a mm/yr. The measurement of mean sea-level change from satellite altimetry requires an extreme stability of the altimeter measurement system since the signal being measured is at the level of a few mm/yr. This means that the orbit and reference frame within which the altimeter measurements are situated, and the associated altimeter corrections, must be stable and accurate enough to permit a robust MSL estimate. Foremost, orbit quality and consistency are critical to satellite altimeter measurement accuracy. The orbit defines the altimeter reference frame, and orbit error directly affects the altimeter measurement. Orbit error remains a major component in the error budget of all past and present altimeter missions. For example, inconsistencies in the International Terrestrial Reference Frame (ITRF) used to produce the precision orbits at different times cause systematic inconsistencies to appear in the multimission time-frame between TOPEX and Jason-1, and can affect the intermission calibration of these data. In an effort to adhere to cross mission consistency, we have generated the full time series of orbits for TOPEX/Poseidon (TP), Jason-1, and OSTM based on recent improvements in the satellite force models, reference systems, and modeling strategies. The recent release of the entire revised Jason-1 Geophysical Data Records, and recalibration of the microwave radiometer correction also require the further re-examination of inter-mission consistency issues. Here we present an assessment of these recent improvements to the accuracy of the 17 -year sea surface height time series, and evaluate the subsequent impact on global and regional mean sea level estimates.

Beckley, Brian D.↗

2020 IEEE PES Innovative Smart Grid Technologies Europe (ISGT-Europe)

Recent proliferation of distributed energy sources in distribution or sub-transmission systems necessitates close monitoring of these three-phase power grids which typically operate under unbalanced loading conditions. Unlike the transmission systems where the network equations are commonly based on the positive sequence component models, a detailed three phase model will have to be used in implementing network applications for these systems. In the specific case of the state estimator, where measurement and parameter errors may bias the solution, bad data and parameter error detection algorithms should also be incorporated. Implementing the state estimator and error detection algorithms for three-phase systems impose additional computational burden and modifications to the state estimation code. This paper proposes a practical solution to avoid these issues by using synchronized phasor measurements and modal decoupling. The previously developed parameter error detection algorithm based on the normalized Lagrange multipliers (NLM) test is applied to the measurements independently in each mode in parallel, not only saving CPU time but also avoiding new code development for a three-phase estimator. Different parameter error scenarios are created and tested to verify the effectiveness of the proposed error detection approach.

Khalili, Ramtin↗

Results from a Sting Whip Correction Verification Test at the Langley 16-Foot Transonic Tunnel

In recent years, great strides have been made toward correcting the largest error in inertial Angle of Attack (AoA) measurements in wind tunnel models. This error source is commonly referred to as 'sting whip' and is caused by aerodynamically induced forces imparting dynamics on sting-mounted models. These aerodynamic forces cause the model to whip through an arc section in the pitch and/or yaw planes, thus generating a centrifugal acceleration and creating a bias error in the AoA measurement. It has been shown that, under certain conditions, this induced AoA error can be greater than one third of a degree. An error of this magnitude far exceeds the target AoA goal of 0.01 deg established at NASA Langley Research Center (LaRC) and elsewhere. New sting whip correction techniques being developed at LaRC are able to measure and reduce this sting whip error by an order of magnitude. With this increase of accuracy, the 0.01 deg AoA target is achievable under all but the most severe conditions.

Crawford, B. L.↗

Clouds and Earth Radiant Energy System (CERES), a Review: Past, Present and Future

The Clouds and Earth Radiant Energy System (CERES) project s objectives are to measure the reflected solar radiance (shortwave) and Earth-emitted (longwave) radiances and from these measurements to compute the shortwave and longwave radiation fluxes at the top of the atmosphere (TOA) and the surface and radiation divergence within the atmosphere. The fluxes at TOA are to be retrieved to an accuracy of 2%. Improved bidirectional reflectance distribution functions (BRDFs) have been developed to compute the fluxes at TOA from the measured radiances with errors reduced from ERBE by a factor of two or more. Instruments aboard the Terra and Aqua spacecraft provide sampling at four local times. In order to further reduce temporal sampling errors, data are used from the geostationary meteorological satellites to account for changes of scenes between observations by the CERES radiometers. A validation protocol including in-flight calibrations and comparisons of measurements has reduced the instrument errors to less than 1%. The data are processed through three editions. The first edition provides a timely flow of data to investigators and the third edition provides data products as accurate as possible with resources available. A suite of cloud properties retrieved from the MODerate-resolution Imaging Spectroradiometer (MODIS) by the CERES team is used to identify the cloud properties for each pixel in order to select the BRDF for each pixel so as to compute radiation fluxes from radiances. Also, the cloud information is used to compute radiation at the surface and through the atmosphere and to facilitate study of the relationship between clouds and the radiation budget. The data products from CERES include, in addition to the reflected solar radiation and Earth emitted radiation fluxes at TOA, the upward and downward shortwave and longwave radiation fluxes at the surface and at various levels in the atmosphere. Also at the surface the photosynthetically active radiation and ultraviolet radiation (total, UVA and UVB) are computed. The CERES instruments aboard the Terra and Aqua spacecraft have served well past their design life times. A CERES instrument has been integrated onto the NPP platform and is ready for launch in 2011. Another CERES instrument is being built for launch in 2014, and plans are being made for a series of follow-on missions.

Smith, G. L.↗

Low-Energy Proton Testing Methodology

Use of low-energy protons and high-energy light ions is becoming necessary to investigate current-generation SEU thresholds. Systematic errors can dominate measurements made with low-energy protons. Range and energy straggling contribute to systematic error. Low-energy proton testing is not a step-and-repeat process. Low-energy protons and high-energy light ions can be used to measure SEU cross section of single sensitive features; important for simulation.

Pellish, Jonathan A.↗

A four-probe thermal transport measurement method for nanostructures

Several experimental techniques reported in recent years have enabled the measurement of thermal transport properties of nanostructures. However, eliminating the contact thermal resistance error from the measurement results has remained a critical challenge. Here, we report a different four-probe measurement method that can separately obtain both the intrinsic thermal conductance and the contact thermal resistance of individual nanostructures. The measurement device consists of four microfabricated, suspended metal lines that act as resistive heaters and thermometers, across which the nanostructure sample is assembled. The method takes advantage of the variation in the heat flow along the suspended nanostructure and across its contacts to the four suspended heater and thermometer lines, and uses sixteen sets of temperature and heat flow measurements to obtain nine of the thermal resistances in the measurement device and the nanostructure sample, including the intrinsic thermal resistance and the two contact thermal resistances to the middle suspended segment of the nanostructure. Two single crystalline Si nanowires with different cross sections are measured in this work to demonstrate the effectiveness of the method. This four-probe thermal transport measurement method can lead to future discoveries of unique size-dependent thermal transport phenomena in nanostructures and low-dimensional materials, in addition to providing reliable experimental data for calibrating theoretical models.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Accuracy of the determination of mean anomalies and mean geoid undulations from a satellite gravity field mapping mission

Improved knowledge of the Earth's gravity field was obtained from new and improved satellite measurements such as satellite to satellite tracking and gradiometry. This improvement was examined by estimating the accuracy of the determination of mean anomalies and mean undulations in various size blocks based on an assumed mission. In this report the accuracy is considered through a commission error due to measurement noise propagation and a truncation error due to unobservable higher degree terms in the geopotential. To do this the spectrum of the measurement was related to the spectrum of the disturbing potential of the Earth's gravity field. Equations were derived for a low-low (radial or horizontal separation) mission and a gradiometer mission. For a low-low mission of six month's duration, at an altitude of 160 km, with a data noise of plus or minus 1 micrometers sec for a four second integration time, we would expect to determine 1 deg x 1 deg mean anomalies to an accuracy of plus or minus 2.3 mgals and 1 deg x 1 deg mean geoid undulations to plus or minus 4.3 cm. A very fast Fortran program is available to study various mission configurations and block sizes.

Jekeli, C.↗

Experimental techniques for evaluating steady-state jet engine performance in an altitude facility

Jet engine calibration tests were conducted in an altitude facility using a contoured bellmouth inlet duct, four fixed-area water-cooled exhaust nozzles, and an accurately calibrated thrust measuring system. Accurate determination of the airflow measuring station flow coefficient, the flow and thrust coefficients of the exhaust nozzles, and the experimental and theoretical terms in the nozzle gross thrust equation were some of the objectives of the tests. A primary objective was to develop a technique to determine gross thrust for the turbojet engine used in this test that could also be used for future engine and nozzle evaluation tests. The probable error in airflow measurement was found to be approximately 0.6 percent at the bellmouth throat design Mach number of 0.6. The probable error in nozzle gross thrust measurement was approximated 0.6 percent at the load cell full-scale reading.

Smith, J. M.↗

Structure classification and melting temperature prediction in octet AB solids via machine learning

Machine learning methods are being increasingly used in condensed matter physics and materials science to classify crystals structures and predict material properties. However, the reliability of these methods for a given problem, especially when large data sets are unavailable, has not been well studied. By addressing the tasks of classifying crystal structure and predicting melting temperatures of the octet subset of AB solids, we performed such a study and found potential problems with using machine learning methods on relatively small data sets. At the same time, however, we can reaffirm the potential power of such methods for these tasks. In particular, we uncovered an important new material feature, the excess Born effective charge, that significantly increased the accuracy of the predictions for the classification problem we defined. This discovery leads us to propose a new scale for the degree of ionicity and covalency in these solids. More specifically, we partitioned the crystal structures of a set of 75 octet solids into those that are ionic and covalent bonded and thus performed a binary classification task. We found that using the standard indices (r σ ,r π ), suggested by St. John and Bloch several decades ago, enabled an average success in classification of 92%. Using just r σ and the excess Born effective charge ΔZ A of the A atom enabled an average success of 97%, but we also found relatively large variations about these averages that were dependent on how certain machine learning methods were used and for which a standard deviation was not a proper measure of the degree of confidence we can place in either average. Instead, we calculated and report with 95 % confidence that the traditional classification pair predicts an accuracy in the interval [ 89%, 95%] and the accuracy of the new pair lies in the interval [96 %, 99%]. For melting temperature predictions, the size of our data set was 46. We estimate the root-mean-squared error of our resulting model to be 11% of the mean melting temperature of the data, but we note that if the accuracy of this predicted error is itself measured, our estimated fitting error itself has a root-mean-square error of 50%. In short, what we illustrate is that classification and regression predictions can vary significantly, depending on the details of how machine learning methods are applied to small data sets. This variation makes it important, if not essential, to average the predictions and compute confidence intervals about these averages to report results meaningfully. However, when properly used, these statistical methods can advance our understanding and improve predictions of material properties even for small data sets.

36 MATERIALS SCIENCE↗

Cosmological evidence for leptonic asymmetry after Planck

Recently, the PLANCK satellite found a larger and most precise value of the matter energy density, that impacts on the present values of other cosmological parameters such as the Hubble constant H{sub 0}, the present cluster abundances S{sub 8}, and the age of the Universe t{sub U}. The existing tension between PLANCK determination of these parameters in the frame of the base ΛCDM model and their determination from other measurements generated lively discussions, one possible interpretation being that some sources of systematic errors in cosmological measurements are not completely understood. An alternative interpretation is related to the fact that the CMB observations, that probe the high redshift Universe are interpreted in terms of cosmological parameters at present time by extrapolation within the base ΛCDM model that can be inadequate or incomplete. In this paper we quantify this tension by exploring several extensions of the base ΛCDM model that include the leptonic asymmetry. We set bounds on the radiation content of the Universe and neutrino properties by using the latest cosmological measurements, imposing also self-consistent BBN constraints on the primordial helium abundance. For all asymmetric cosmological models we find the preference of cosmological data for smaller values of active and sterile neutrino masses. This increases the tension between cosmological and short baseline neutrino oscillation data that favors a sterile neutrino with the mass of around 1 eV. For the case of degenerate massive neutrinos, we find that the discrepancies with the local determinations of H{sub 0}, and t{sub U} are alleviated at ∼ 1.3σ level while S{sub 8} is in agreement with its determination from CFHTLenS survey data at ∼ 1σ and with the prediction of cluster mass-observation relation at ∼ 0.5σ. We also find 2σ statistical preference of the cosmological data for the leptonic asymmetric models involving three massive neutrino species and neutrino direct mass hierarchy. We conclude that the current cosmological data favor the leptonic asymmetric extension of the base ΛCDM model and normal neutrino mass hierarchy over the models with additional sterile neutrino species and/or inverted neutrino mass hierarchy.

79 ASTRONOMY AND ASTROPHYSICS↗

Accuracy of vertical velocity determination

Typical wind spectra taken at Poker Flat, Alaska, using the vertically oriented antenna show velocities of 10's of cm to meters per second and spectral widths winds of 0.5 to 1 m/s. The potential errors in such measurements can be broken down into three categories: (1) those due to instrumental parameters and data processing, (2) those due to specular returns from non-horizontal surfaces, and (3) those due to other physical effects. Error analysis in vertical velocity measurement is further discussed.

Riddle, A. C.↗

Signal-Induced Noise Effects in a Photon Counting System for Stratospheric Ozone Measurement

A significant source of error in making atmospheric differential absorption lidar ozone measurements is the saturation of the photomultiplier tube by the strong, near field light return. Some time after the near field light signal is gone, the photomultiplier tube gate is opened and a noise signal, called signal-induced noise, is observed. Research reported here gives experimental results from measurement of photomultiplier signal-induced noise. Results show that signal-induced noise has several decaying exponential signals, suggesting that electrons are slowly emitted from different surfaces internal to the photomultiplier tube.

Harper, David B.↗