Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MICROSCOPES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

A microchannel for in vitro imaging of erythrocyte shape transformations by video microscopic technique

SummaryAn in-house fabricated microfluidic channel was developed using easily available materials (glass slide, transparency shapes, polyvinyl chloride tubes, coverslip, and epoxy) and manual positioning techniques with the aid of a profile projector, in the absence of other fabrication facilities.{sup 2,3,11–15} Despite the limitations of being less accurate and more laborious, manual methods offer an easy, inexpensive, and readily implementable alternative to automated ones. Being economical, they enable testing of newer models and hypothesis, development of new designs, and trail stage/prototype experimentation. Once the effectiveness of the developed channel is established, the manual fabrication method can eventually be automated. So far as erythrocyte deformability is concerned, the microchannel thus fabricated enabled multishape erythrocyte deformability analysis in contrast to the unishape approach by earlier studies.{sup 11–15,19} Though the microchannel in this study has larger width (30 μm) compared to the mean RBC diameter (~8 μm), it allows free orientation of cells and larger variation of shear condition across the channel cross section. Consequently, both asymmetrical and axial shapes were observed during the flow. Hence, it may be concluded that a larger cross section and medium to high flow (10–20 mm/s) may be appropriate for multishape characterization of erythrocytes in dilute suspensions. The issue of determining the DI for several deformed shapes and sorting them from other interacting and nondeforming RBCs could be handled with more flexible software techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Patterning corrosion-susceptible metallic alloys for digital image correlation in a scanning electron microscope: Patterning corrosion susceptible alloys for SEM-DIC

Here we investigate the self-assembly of gold nanoparticles on the surface of magnesium functionalized with 3-(aminopropyl)trimethoxysilane or 3-(mercaptopropyl)trimethoxysilane. These nanoparticles served as a speckle pattern for high magnification deformation tracking via digital image correlation combined with scanning electron microscopy. Controlling the pH of the gold nanoparticle suspension to a specific basicity passivated corrosion in magnesium and in three of its alloys to enable proper nanoparticle bonding and self-assembly. Magnesium was used as a model material as it is particularly difficult to modify for self-assembly because of its propensity to quickly form a thick oxide, hydroxide, and carbonate layer in the presence of oxygen, water, and carbon dioxide, respectively. Moreover, it corrodes in acidic and slightly basic solutions, further complicating the self-assembly process. Due to these difficulties, the successful self-assembly of nanoparticles on magnesium has not previously been reported, to the best of the authors' knowledge. This technique is potentially amendable to other corrosion-susceptible materials. Gold nanoparticles were self-assembled in a uniformly dispersed random distribution on pure cast magnesium, cast AM60 (Mg-6Al-0.5Mn), rolled WE43 (Mg-4Y-3Nd/Gd), and extruded ZE20 (Mg-2Zn-0.2Ce).

36 MATERIALS SCIENCE↗

Microscopic activated dynamics theory of the shear rheology and stress overshoot in ultradense glass-forming fluids and colloidal suspensions

We formulate a particle and force level, activated dynamics-based statistical mechanical theory for the continuous startup nonlinear shear rheology of ultradense glass-forming hard sphere fluids and colloidal suspensions in the context of the elastically collective nonlinear Langevin equation approach and a generalized Maxwell model constitutive equation. Activated structural relaxation is described as a coupled local-nonlocal event involving caging and longer range collective elasticity which controls the characteristic stress relaxation time. Theoretical predictions for the deformation-induced enhancement of mobility, the onset of relaxation acceleration at remarkably low values of stress, strain, or shear rate, apparent power law thinning of the steady-state structural relaxation time and viscosity, a nonvanishing activation barrier in the shear thinning regime, an apparent Herschel–Buckley form of the shear rate dependence of the steady-state shear stress, exponential growth of different measures of a yield or flow stress with packing fraction, and reduced fragility and dynamic heterogeneity under deformation were previously shown to be in good agreement with experiments. The central new question we address here is the defining feature of the transient response—the stress overshoot. In contrast to the steady-state flow regime, understanding the transient response requires an explicit treatment of the coupled nonequilibrium evolution of structure, elastic modulus, and stress relaxation time. We formulate a new quantitative model for this aspect in a physically motivated and computationally tractable manner. Theoretical predictions for the stress overshoot are shown to be in good agreement with experimental observations in the metastable ultradense regime of hard sphere colloidal suspensions as a function of shear rate and packing fraction, and accounting for deformation-assisted activated motion appears to be crucial for both the transient and steady-state responses.

Mechanics↗

Three dimensions, two microscopes, one code: Automatic differentiation for x-ray nanotomography beyond the depth of focus limit

Conventional tomographic reconstruction algorithms assume that one has obtained pure projection images, involving no within-specimen diffraction effects nor multiple scattering. Advances in x-ray nanotomography are leading toward the violation of these assumptions, by combining the high penetration power of x-rays, which enables thick specimens to be imaged, with improved spatial resolution that decreases the depth of focus of the imaging system. We describe a reconstruction method where multiple scattering and diffraction effects in thick samples are modeled by multislice propagation and the 3D object function is retrieved through iterative optimization. We show that the same proposed method works for both full-field microscopy and for coherent scanning techniques like ptychography. Our implementation uses the optimization toolbox and the automatic differentiation capability of the open-source deep learning package TensorFlow, demonstrating a straightforward way to solve optimization problems in computational imaging with flexibility and portability.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗