Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Low Resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

TU-A-12A-12: Improved Airway Measurement Accuracy for Low Dose Quantitative CT (qCT) Using Statistical (ASIR), at Reduced DFOV, and High Resolution Kernels in a Phantom and Swine Model

Purpose: Quantitative accuracy of Iodine Hounsfield Unit (HU) in conventional single-kVp scanning is susceptible to beam-hardening effect. Dual-energy CT has unique capabilities of quantification using monochromatic CT images, but this scanning mode requires the availability of the state-of-the-art CT scanner and, therefore, is limited in routine clinical practice. Purpose of this work was to develop a beam-hardening-correction (BHC) for single-kVp CT that can linearize Iodine projections at any nominal energy, apply this approach to study Iodine response with respect to keV, and compare with dual-energy based monochromatic images obtained from material-decomposition using 80kVp and 140kVp. Methods: Tissue characterization phantoms (Gammex Inc.), containing solid-Iodine inserts of different concentrations, were scanned using GE multi-slice CT scanner at 80, 100, 120, and 140 kVp. A model-based BHC algorithm was developed where Iodine was estimated using re-projection of image volume and corrected through an iterative process. In the correction, the re-projected Iodine was linearized using a polynomial mapping between monochromatic path-lengths at various nominal energies (40 to 140 keV) and physically modeled polychromatic path-lengths. The beam-hardening-corrected 80kVp and 140kVp images (linearized approximately at effective energy of the beam) were used for dual-energy material-decomposition in Water-Iodine basis-pair followed by generation of monochromatic images. Characterization of Iodine HU and noise in the images obtained from singlekVp with BHC at various nominal keV, and corresponding dual-energy monochromatic images, was carried out. Results: Iodine HU vs. keV response from single-kVp with BHC and dual-energy monochromatic images were found to be very similar, indicating that single-kVp data may be used to create material specific monochromatic equivalent using modelbased projection linearization. Conclusion: This approach may enable quantification of Iodine contrast enhancement and potential reduction in injected contrast without using dual-energy scanning. However, in general, dual-energy scanning has unique value in material characterization and quantification, and its value cannot be discounted. GE Healthcare Employee.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of light output on the timing resolution of organic glass scintillator bars in a dual-ended readout configuration

The effectiveness of detector system modeling and validation depends on the quality of characterization performed on the system. For nuclear nonproliferation applications, which require detectors to address complex and variable field conditions, access to accurate system models is essential. This study presents the timing characterization of organic glass scintillator bars used in an imaging system developed at the University of Michigan. 137 Cs and 60 Co gamma-ray sources were used to determine the coincidence time resolution as a function of measured light output for two Compton scatter events between two organic glass scintillator bars. Timing resolution for two events, each with light output ranging from 100 to 1100 keVee were characterized. The resulting data were fit to a parametric function that was validated to agree with experimental results within ±25 ps. Simulations were performed to establish appropriate calibration points for each organic scintillator, thereby ensuring accurate calibration of light output values during analysis. This work successfully characterized the light output dependence of the coincidence timing resolution of a pair of organic glass detectors for use in an imaging system. Depending on the amount of scintillation light output from the events, the full width at half maximum of the measured coincidence time resolution ranged from 653.2 ± 16.1 ps for low light yields, 100 keVee, to 121.0 ± 8.4 ps for higher yields at 1100 keVee. The insights obtained from the timing resolution behavior will allow for accurate simulation capabilities in future security and verification efforts using scatter-based imaging systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Wide Field X-ray Telescope Mission--A Digital Sky Survey in X-rays

Sensitive surveys of the X-ray universe have been limited to small areas of the sky due to the intrinsically small field of view of Wolter-I X-ray optics. High angular resolution is needed to achieve a low background per source, minimize source confusion, and distinguish point from extended objects. WFXT consists of three co-aligned wide field X-ray telescopes with a 1 deg. field of view and a < or approx. 10''(goal of 5'') angular resolution (HEW) over the full field. Total effective area at 1 keV will be >5000 cm{sup -2}. WFXT will perform three extragalactic surveys that will cover most of the sky to 100-1000 times the sensitivity of the ROSAT All Sky Survey, > ir approx. 2000 deg{sup 2} to deep Chandra or XMM-Newton sensitivity, and > or approx. 100 deg{sup 2} to the deepest Chandra sensitivity. WFXT will generate a legacy X-ray dataset of a half million clusters and groups of galaxies to z{approx_equal}2, also characterizing the physics of the intracluster gas for a significant fraction of them, thus providing an unprecedented data set for cosmological applications; it will detect >10{sup 7} AGN to z>6, again obtaining spectra for a substantial fraction, to study the growth of supermassive black holes; it will detect >10{sup 5} normal/starburst galaxies; and it will detect and characterize star formation regions across the Galaxy. WFXT is the only X-ray survey mission that will match, in area and sensitivity, the next generation of wide-area optical, IR and radio surveys.

79 ASTRONOMY AND ASTROPHYSICS↗

High Dose Rate Irradiations of Enduray Vision System for Nuclear Inspections

Higher radiation-hardened video cameras are needed in the operation and remote handling of equipment in nuclear reactor inspection and refueling applications. Vega Wave Systems, Inc. has developed a radiation-hardened vision system for nuclear energy applications. This vision system has been developed under several small business innovative research programs (SBIRs) from the U.S. Department of Energy, and the previous GAIN voucher program at Argonne National Laboratory (ANL) was successful in demonstrating that a prototype of the camera is radiation-hard up to at least 525 kGy (5.25 × 106 rad, Si equivalent) at dose rates of 10 kGy/hr with no measurable degradation in image quality and no measurable radiation-induced noise (RIN). Vega Wave Systems has developed a new version of the camera with more than 3X the resolution using a new design and new components, and this new design requires radiation-hardness qualification for marketplace acceptance. The program described in this report provided high radiation-hardness testing of this redesigned high-resolution vision system using the Argonne Low-Energy Accelerator Facility (LEAF). This report presents the results of irradiation tests performed on Vega Wave System’s redesigned high resolution vision system at a dose rate of 9.3 kGy/hr and up to total doses of 1823 kGy. This was an accumulation of 197 hours of irradiation. The results were excellent, providing proof of the redesigned high-resolution vision system’s immunity to high levels of radiation.

42 ENGINEERING↗

Spontaneous generation of athermal phonon bursts within bulk silicon causing excess noise, low energy background events, and quasiparticle poisoning in superconducting sensors

Solid state phonon detectors used in the search for dark matter and coherent neutrino nucleus interactions (CE $v$ NS) require excellent energy resolution (eV-scale or below) and low backgrounds. An unknown source of phonon bursts, the low energy excess (LEE), dominates other above-threshold backgrounds and generates excess shot noise from subthreshold bursts. Here, in this paper, we measure these phonon bursts for 12 days after cooldown in two nearly identical 1 cm 2 silicon detectors that differ only in the thickness of their substrate (1 vs 4 mm thick). We find that both the channel-correlated shot noise and near-threshold shared LEE relax with time since cooldown. Additionally, both the correlated shot noise and LEE rates scale linearly with substrate thickness. When combined with previous measurements of other silicon phonon detectors with different substrate geometries and mechanical support strategies, these measurements strongly suggest that the dominant source of both above and below threshold LEE is the bulk substrate. By monitoring the relation between bias power and excess phonon shot noise, we estimate that the energy scale for subthreshold noise events is 0.68 ± 0.38 meV. In our final dataset, we report a world-leading energy resolution of 258.5 ± 0.4 meV in the 1 mm thick detector. Simple calculations suggest that these silicon substrate phonon bursts are likely a significant source of quasiparticle poisoning in superconducting qubits operated in well shielded and vibration free environments.

Chang, C. L. [Argonne National Laboratory 1 , 9700↗

FLAMES─Fast, Low-Storage, Accurate, and Memory-Efficient Adaptive Sampling─Approach to Resolve Spatially Dependent Dynamics of Molecular Liquids

Many critical phenomena in soft matter occur at large length scales, necessitating the resolution of their structure and dynamics at low wavenumbers. However, resolving wavenumber-dependent dynamics computationally via molecular dynamics simulations presents significant challenges, as these phenomena span several orders of magnitude in both time and length scales, resulting in high computational costs and memory demands. Here, this work highlights the computational and memory challenges associated with analyzing molecular trajectories in reciprocal space and demonstrates a method to address them. We introduce FLAMESFast, Low-storage, Accurate, and Memory-Efficient adaptive Sampling, which is a direct method for calculation of structure factors, allowing us to select only the required number of wavevectors for binning. We also use wavenumber-dependent time steps to extract dynamics. Our FLAMES approach effectively mitigates computational and memory/storage bottlenecks. We demonstrate the method using simulations of a model system, liquid octane, at various temperatures. Comparisons with experimental data and real space computation show that the FLAMES technique achieves high accuracy in resolving temperature- and spatially dependent dynamics while being significantly more computationally efficient and requiring less memory and storage than methods based on a uniform wavevector grid and fixed temporal spacing.

Chen, Guang [Argonne National Laboratory (ANL), Ar↗

Probing intrinsic magnetization dynamics of the Y 3⁢ Fe 5 ⁢O 12 /Bi 2 ⁢Te 3 interface at low temperature

Topological insulator–magnetic insulator (TI–MI) heterostructures hold significant promise in the field of spintronics, offering the potential for manipulating magnetization through topological surface state–enabled spin-orbit torque. However, many TI–MI interfaces are plagued by issues such as contamination within the magnetic insulator layer and the presence of a low-density transitional region of the topological insulator. These interfacial challenges often obscure the intrinsic behavior of the TI–MI system. In this study, we addressed these challenges by depositing sputtered Bi 2 ⁢Te 3 on liquid phase epitaxy grown Y 3 ⁢Fe 5 ⁢O 12 /Gd 3 ⁢Ga 5 ⁢O 12 . The liquid phase epitaxy grown Y 3 ⁢Fe 5 ⁢O 12 has been previously shown to have exceptional interface quality, without an extended transient layer derived from interdiffusion processes of the substrate or impurity ions, thereby eliminating rare-earth impurity-related losses in the MI at low temperatures. At the TI–MI interface, high-resolution depth-sensitive polarized neutron reflectometry confirmed the absence of a low-density transitional growth region of the TI. By overcoming these undesirable interfacial effects, we isolate and probe the intrinsic low-temperature magnetization dynamics and transport properties of the TI–MI interface. In conclusion, our findings revealed strong spin pumping at low temperatures, accompanied by an additional in-plane anisotropy. The enhanced spin pumping at low temperatures is correlated with the observed suppression of bulk conduction and the weak antilocalization in the TI film, highlighting the interplay between the transport and spin pumping behavior in the TI–MI system.

36 MATERIALS SCIENCE↗

WE-AB-207A-01: BEST IN PHYSICS (IMAGING): High-Resolution Cone-Beam CT of the Extremities and Cancellous Bone Architecture with a CMOS Detector

Purpose: Extremity cone-beam CT (CBCT) with an amorphous silicon (aSi) flat-panel detector (FPD) provides low-dose volumetric imaging with high spatial resolution. We investigate the performance of the newer complementary metal-oxide semiconductor (CMOS) detectors to enhance resolution of extremities CBCT to ∼0.1 mm, enabling morphological analysis of trabecular bone. Quantitative in-vivo imaging of bone microarchitecture could present an important advance for osteoporosis and osteoarthritis diagnosis and therapy assessment. Methods: Cascaded systems models of CMOS- and FPD-based extremities CBCT were implemented. Performance was compared for a range of pixel sizes (0.05–0.4 mm), focal spot sizes (0.3–0.6 FS), and x-ray techniques (0.05–0.8 mAs/projection) using detectability of high-, low-, and all-frequency tasks for a nonprewhitening observer. Test-bench implementation of CMOS-based extremity CBCT involved a Teledyne DALSA Xineos3030HR detector with 0.099 mm pixels and a compact rotating anode x-ray source with 0.3 FS (IMD RTM37). Metrics of bone morphology obtained using CMOS-based CBCT were compared in cadaveric specimens to FPD-based system using a Varian PaxScan4030 (0.194 mm pixels). Results: Finer pixel size and reduced electronic noise for CMOS (136 e compared to 2000 e for FPD) resulted in ∼1.9× increase in detectability for high-frequency tasks and ∼1.1× increase for all-frequency tasks. Incorporation of the new x-ray source with reduced focal spot size (0.3 FS vs. 0.5 FS used on current extremities CBCT) improved detectability for CMOS-based CBCT by ∼1.7× for high-frequency tasks. Compared to FPD CBCT, the CMOS detector yielded improved agreement with micro-CT in measurements of trabecular thickness (∼1.7× reduction in relative error), bone volume (∼1.5× reduction), and trabecular spacing (∼3.5× reduction). Conclusion: Imaging performance modelling and experimentation indicate substantial improvements for high-frequency imaging tasks through adoption of the CMOS detector and small FS x-ray source, motivating the use of these components in a new system for quantitative in-vivo imaging of trabecular bone. Financial Support: US NIH grant R01EB018896. Qian Cao is a Howard Hughes Medical Institute International Student Research Fellow. Disclosures: W Zbijewski, J Siewerdsen and A Sisniega receive research funding from Carestream Health.

60 APPLIED LIFE SCIENCES↗

Si(hhm) surfaces: Templates for developing nanostructures

The fabrication of ordered low-dimensional structures on clean and metal-atom-decorated stepped Si(557) and Si(556) surfaces is discussed. The formation conditions and atomic structure of regular step systems on clean Si(557) 7 × 7 and Si(556) 7 × 7 surfaces are studied. The atomic structure of stepped Si(hhm), Ag/Si(557), and Gd/Si(557) surfaces is studied using high-resolution scanning tunneling microscopy and low-energy electron diffraction. The possibility of fabricating 1D and 2D structures of gadolinium and silver atoms on the Si(557) surface is demonstrated.

36 MATERIALS SCIENCE↗

Tuning the Superconducting Transition Temperature of Co-sputtered Iridium and Platinum Films

A superconducting film with a tunable low transition temperature (Tc) is required in high-resolution Transition-Edge Sensor (TES) detectors, which have applications including dark matter detection, low threshold coherent elastic neutrino nucleus scattering measurement, and X-ray spectroscopy. We have been investigating a new approach to tune the Tc of superconducting thin films fabricated by co-sputtering Iridium and Platinum. The effects of Pt concentration and deposition parameters on the films' structural, electrical, and superconducting properties have been studied. AFM and XRD techniques and low temperature resistance measurements have been utilized for film characterization. By varying the Pt concentration and deposition parameters when co-sputtering, we have successfully achieved controllable tuning of Tc in the range of 30-200 mK. The experimental results demonstrate co-sputtering as a viable method for controlling the Tc of Ir-based thin films that can be applied to fabricating high-resolution TESs.

Yefremenko, V. G.↗

Direct Observation of Wet Biological Samples by Graphene Liquid Cell Transmission Electron Microscopy

Recent development of liquid phase transmission electron microscopy (TEM) enables the study of specimens in wet ambient conditions within a liquid cell; however, direct structural observation of biological samples in their native solution using TEM is challenging since low-mass biomaterials embedded in a thick liquid layer of the host cell demonstrate low contrast. Furthermore, the integrity of delicate wet samples is easily compromised during typical sample preparation and TEM imaging. To overcome these limitations, we introduce a graphene liquid cell (GLC) using multilayer graphene sheets to reliably encapsulate and preserve biological samples in a liquid for TEM observation. We achieve nanometer scale spatial resolution with high contrast using low-dose TEM at room temperature, and we use the GLC to directly observe the structure of influenza viruses in their native buffer solution at room temperature. The GLC is further extended to investigate whole cells in wet conditions using TEM. We also demonstrate the potential of the GLC for correlative studies by TEM and fluorescence light microscopy imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

First-Principles insights into group-V impurities and their impact on germanium detector performance

The outstanding properties of high-purity germanium (HPGe) detectors, such as excellent energy resolution, high energy sensitivity, and a low background-to-signal ratio, make them essential and ideal candidates for detecting particle signatures in nuclear processes such as neutrino-less double beta decay (0νββ). However, the presence of defects and impurities in HPGe crystals can lead to charge trapping, which affects carrier mobility and results in significant energy resolution degradation. In this work, we employ density functional theory with a hybrid functional to study the energetics of possible point defects in Ge. Our findings indicate that group-V impurities form more readily in Ge compared to vacancy and interstitial of Ge. Unlike N dopants, which yield deep trap states, P, As, and Sb create shallow traps close to the conduction band edge of Ge. Furthermore, we predict that group-V defects can condense into defect complexes with Ge vacancies. These vacancy-impurity complexes form deep traps in Ge, similar to Ge vacancies, suggesting that both vacancies and vacancy-impurity complexes contribute to charge trapping in these detectors, thereby diminishing their performance.

36 MATERIALS SCIENCE↗

Multielectrode electrochemical cell for in situ structural characterization of amorphous thin-film catalysts using high-energy X-ray scattering

A multielectrode-based electrochemical cell allows the structural characterization of an amorphous thin-film water oxidation catalyst under various electrochemical potentials using high-energy X-ray scattering and atomic pair distribution function (PDF) techniques. A multielectrode with five electrodes provides a sufficiently low background signal to enable high-energy X-ray scattering (HEXS) measurements and amplifies the extremely low HEXS signals from samples for high-resolution PDF analysis of in situ data from thin-film catalysts. Glassy carbon (GC) creates a relatively low intensity HEXS pattern and is used as a working electrode. Instead of a three-dimensional (3D) porous electrode architecture, the flat geometry of the electrode enables various deposition techniques to be used for the preparation of a highly conductive metal oxide layer. PDF analysis demonstrates high spatial resolution for a 230 nm thick amorphous iridium oxide film deposited on two roughened 60 µm thick GC electrodes. The PDF analysis resolves the domain size and distinguishes changes in fine structure which are directly correlated with the structure and function of the catalysts. In conclusion, the results bring the opportunity to analyze the structure of nanometre-scale amorphous thin-film catalysts in an electrolyte-compatible and compact 3D-printed electrochemical cell in a three-electrode configuration.

36 MATERIALS SCIENCE↗

Thermal and fast neutron detection in chemical vapor deposition single-crystal diamond detectors

Recently, a compact solid-state neutron detector capable of simultaneously detecting thermal and fast neutrons was proposed [M. Marinelli et al., Appl. Phys. Lett. 89, 143509 (2006)]. Its design is based on a p-type/intrinsic/metal layered structure obtained by Microwave Plasma Chemical Vapor Deposition (CVD) of homoepitaxial diamond followed by thermal evaporation of an Al contact and a {sup 6}LiF converting layer. Fast neutrons are directly detected in the CVD diamond bulk, since they have enough energy to produce the {sup 12}C(n,{alpha}){sup 9}Be reaction in diamond. Thermal neutrons are instead converted into charged particles in the {sup 6}LiF layer through the {sup 6}Li(n,{alpha})T nuclear reaction. These charged particles are then detected in the diamond layer. The thickness of the {sup 6}LiF converting layer and the CVD diamond sensing layer affect the counting efficiency and energy resolution of the detector both for low- (thermal) and high-energy neutrons. An analysis is carried out on the dynamics of the {sup 6}Li(n,{alpha})T and the {sup 12}C(n,{alpha}){sup 9}Be reactions products, and the distribution of the energy released inside the sensitive layer is calculated. The detector counting efficiency and energy resolution were accordingly derived as a function of the thickness of the {sup 6}LiF and CVD diamond layers, both for thermal and fast neutrons, thus allowing us to choose the optimum detector design for any particular application. Comparison with experimental results is also reported.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microfluidic-based mini-metagenomics enables discovery of novel microbial lineages from complex environmental samples

Metagenomics and single-cell genomics have enabled genome discovery from unknown branches of life. However, extracting novel genomes from complex mixtures of metagenomic data can still be challenging and represents an ill-posed problem which is generally approached with ad hoc methods. Here we present a microfluidic-based mini-metagenomic method which offers a statistically rigorous approach to extract novel microbial genomes while preserving single-cell resolution. We used this approach to analyze two hot spring samples from Yellowstone National Park and extracted 29 new genomes, including three deeply branching lineages. The single-cell resolution enabled accurate quantification of genome function and abundance, down to 1% in relative abundance. Our analyses of genome level SNP distributions also revealed low to moderate environmental selection. The scale, resolution, and statistical power of microfluidic-based mini-metagenomics make it a powerful tool to dissect the genomic structure of microbial communities while effectively preserving the fundamental unit of biology, the single cell.

Life Sciences & Biomedicine - Other Topics↗

Ambient field seismology in critical zone hydrological sciences

Passive ambient noise monitoring is an emerging tool in environmental seismology, leveraging the ambient seismic field to assess temporal variations in shallow subsurface properties. This review focuses on the potential and challenges of using scattered coda waves from noise correlation functions to monitor critical zone dynamics. The sensitivity of seismic velocities to various environmental factors, including precipitation, snowmelt, atmospheric pressure, and groundwater fluctuations, underscores the method’s versatility. While coda waves excel in detecting subtle changes due to their scattered nature, ballistic waves provide higher spatial resolution, albeit with challenges in source stability. Advances in seismic sensing, including distributed acoustic sensing and low-cost geophone networks, have enabled high-resolution monitoring of hydrological processes, subsurface deformation, and seismic hazards. Integrating seismic data with hydrological models provides insights into water storage, pore pressure changes, and soil moisture dynamics. However, limitations in spatial resolution, calibration with ground truth data, and coupled effects between environmental factors remain key challenges. This review emphasizes the importance of interdisciplinary approaches in refining methodologies, enhancing sensor deployments, and addressing data gaps. Passive seismic monitoring offers opportunities to understand critical zone processes and their broader impacts on seismic hazards and environmental sustainability.

58 GEOSCIENCES↗

In-situ synchrotron X-ray micro-diffraction investigation of ultra-low-strain deformation microstructure in laminated Ti-Al composites

An ultra-low-strain deformation microstructure was revealed for the first time non-destructively in the bulk interior of an annealed laminated Ti-Al composite-in the "fully recrystallized" Al layer-by a synchrotron-based micro-diffraction technique, namely differential aperture X-ray microscopy (DAXM), through real space mapping with a very high angular resolution (0.01 degrees). This ultra-low-strain deformation microstructure was found to result from the thermal stress, induced during cooling after annealing, due to the different coefficients of thermal expansion for the Ti and Al layers. The annealed sample was further tensile deformed to a strain of 1.66% and followed by in situ DAXM and analyzed by various misorientation mapping methods. The results pointed to the important effects of the initial microstructure and the interface constraint, as well as the grain size and crystal orientation, on the plastic deformation. A gradient in dislocation density from the layer interface to the center was found in the Al layer of the annealed sample, and this gradient increased slightly during tensile deformation. The variation of the dislocation density was further discussed based on the activation and interaction of dislocations in grains of different sizes and orientations during plastic deformation. The findings of this study provided valuable insights in understanding the constraint effect of the laminated metal composite and the design of novel composite materials. (c) 2020 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

Crystallographic orientation↗

Lessons Learned in the Update of a Safety Limit for the High Flux Isotope Reactor

A recent unreviewed safety question (USQ) regarding a portion of the High Flux Isotope Reactor (HFIR) transient decay heat removal analysis focused on applicability of a heat transfer correlation at the low flow end of reactor operations. During resolution of this issue, review of the correlations used to establish the safety limit (SL) on reactor flux-to-flow ratio revealed the need to change the magnitude of the SL at the low flow end of reactor operations and the need to update the hot spot fuel damage criteria to incorporate current knowledge involving parallel channel flow stability. Because of the original safety design strategy for the reactor, resolution of the issues for the flux-to-flow ratio involved reevaluation of all key process variable SLs and limiting control settings (LCSs) using the current version of the heat transfer analysis code for the reactor. Goals of the work involved updating and upgrading the SL analysis where necessary, while preserving the safety design strategy for the reactor. Changes made include revisions to the safety design criteria at low flows to address the USQ, update of the process- and analysis input-variable uncertainty considerations, and upgrade of the safety design criteria at high flow. The challenges faced during update/upgrade of this SL and LCS are typical of the problems found in the integration of safety into the design process for a complex facility. In particular, the problems addressed in the area of instrument uncertainties provide valuable lessons learned for establishment and configuration control of SLs for large facilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗