Assess Calibration Consistency of MODIS and AVHRR Thermal Infrared Bands Using SNO Observations Corrected for Atmospheric Effects

Monitoring environmental changes from space requires extremely well-calibrated observations to achieve the necessary high accuracy and stability. The calibration differences between the Moderate Resolution Imaging Spectroradiometer (MODIS) and the Advanced Very High Resolution Radiometer (AVHRR) thermal bands provide a valuable quality assessment of the instrument performance. This letter compares the calibration differences between the Aqua MODIS and NOAA-18 AVHRR bands at 11.0 and 12.0 /Lm using simultaneous nadir overpass observations obtained in nearly parallel orbits. Impacts due to the relative spectral-response differences between the two sensors are estimated by MODTRAN simulations with real-time atmospheric profiles of temperature, water vapor, atmospheric pressure and ozone, and surface skin temperatures. Results show that the temperature difference after the removal of atmospheric impacts is within 0.30 K (or 0.40% in radiance) across the effective calibration range (or the 1l.0 l'm band/channel. For the 12.0 pm band, the differences are OAO K (or 0.50%) at the typical radiance and up to 0.70 K (or 0.90%) close to the maximum radiance, indicating an excellent calibration consistency between MODIS and AVHRR for both bands.

Wu, Aisheng↗

Reliability of CGA/LGA/HDI Package Board/Assembly (Final Report)

Package manufacturers are now offering commercial-off-the-shelf column grid array (COTS CGA) packaging technologies in high-reliability versions. Understanding the process and quality assurance (QA) indicators for reliability are important for low-risk insertion of these advanced electronics packages. The previous reports, released in January of 2012 and January of 2013, presented package test data, assembly information, and reliability evaluation by thermal cycling for CGA packages with 1752, 1517, 1509, and 1272 inputs/outputs (I/Os) and 1-mm pitch. It presented the thermal cycling (-55C either 100C or 125C) test results for up to 200 cycles. This report presents up to 500 thermal cycles with quality assurance and failure analysis evaluation represented by optical photomicrographs, 2D real time X-ray images, dye-and-pry photomicrographs, and optical/scanning electron Microscopy (SEM) cross-sectional images. The report also presents assembly challenge using reflowing by either vapor phase or rework station of CGA and land grid array (LGA) versions of three high I/O packages both ceramic and plastic configuration. A new test vehicle was designed having high density interconnect (HDI) printed circuit board (PCB) with microvia-in-pad to accommodate both LGA packages as well as a large number of fine pitch ball grid arrays (BGAs). The LGAs either were assembled onto HDI PCB as an LGA or were solder paste print and reflow first to form solder dome on pads before assembly. Both plastic BGAs with 1156 I/O and ceramic LGAs were assembled. It also presented the X-ray inspection results as well as failures due to 200 thermal cycles. Lessons learned on assembly of ceramic LGAs are also presented.

Ghaffaroam. Reza↗

Evaluation of the VIIRS BRDF, Albedo and NBAR Products Suite and an Assessment of Continuity with the Long Term MODIS Record

Bidirectional Reflectance Distribution Function (BRDF) model parameters, Albedo quantities, and Nadir BRDF Adjusted Reflectance (NBAR) products derived from the Visible Infrared Imaging Radiometer Suite (VIIRS), on the Suomi-NPP (National Polar-orbiting Partnership) satellite are evaluated with spatially representative in situ tower albedometer measurements and through comparison with the MODerate Resolution Imaging Spectroradiometer (MODIS) long term record. White Sky Albedo (WSA), Black Sky Albedo (BSA), NBAR, and Quality Assurance (QA) results show that the VIIRS algorithm is performing well at the global scale and is able to provide global data products comparable with the heritage MODIS (with an absolute bias of 0.0069 for shortwave broadband WSA) despite the spectral, angular, and effective spatial resolution differences between the two sensors. Both VIIRS and MODIS albedo are shown to agree well with in situ albedo measurements at a number of spatially representative sites. This evaluation provides confidence that the high quality, daily VIIRS BRDF model parameters, Albedo, and NBAR products will be able to provide the long term continuity required by the modeling and monitoring communities.

VIIRS↗

Monitoring Water-Related Ecosystems with Earth Observation Data in Support of Sustainable Development Goal (SDG) 6 Reporting

Lack of national data on water-related ecosystems is a major challenge to achieving the Sustainable Development Goal (SDG) 6 targets by 2030. Monitoring surface water extent, wetlands, and water quality from space can be an important asset for many countries in support of SDG 6reporting. We demonstrate the potential for Earth observation (EO) data to support country reporting for SDG Indicator 6.6.1, ‘Change in the extent of water-related ecosystems over time’ and identify important considerations for countries using these data for SDG reporting. The spatial extent of water-related ecosystems, and the partial quality of water within these ecosystems is investigated for seven countries. Data from the Moderate Resolution Imaging Spectroradiometer (MODIS) and Landsat 5, 7, and 8 with Shuttle Radar Topography Mission (SRTM) are used to measure surface water extent at 250 m and 30 m spatial resolution, respectively, in Cambodia, Jamaica, Peru, the Philippines, Senegal, Uganda, and Zambia. The extent of mangroves is mapped at 30 m spatial resolution using Landsat 8 Operational Land Imager (OLI), Sentinel-1, and SRTM data for Jamaica, Peru, and Senegal. Using Landsat 8 and Sentinel 2A imagery, total suspended solids and chlorophyll-a are mapped overtime for a select number of large surface water bodies in Peru, Senegal, and Zambia. All of the EO datasets used are of global coverage and publicly available at no cost. The temporal consistency and long time-series of many of the datasets enable replicability over time, making reporting of change from baseline values consistent and systematic. We find that statistical comparisons between different surface water data products can help provide some degree of confidence for countries during their validation process and highlight the need for accuracy assessments when using EO-based land change data for SDG reporting. We also raise concern that EO data in the context of SDG Indicator 6.6.1reporting may be more challenging for some countries, such as small island nations, than others to use in assessing the extent of water-related ecosystems due to scale limitations and climate variability. Country-driven validation of the EO data products remains a priority to ensure successful data integration in support of SDG Indicator 6.6.1 reporting. Multi-country studies such as this one can be valuable tools for helping to guide the evolution of SDG monitoring methodologies and provide a useful resource for countries reporting on water-related ecosystems. The EO data analyses and statistical methods used in this study can be easily replicated for country-driven validation of EO data products in the future.

Raha Hakimdavar↗

Review of High‐Speed Digital Image Correlation: Advancements and Good Practices

This paper reviews the current state of the art in high‐speed (HS) and ultrahigh‐speed (UHS) digital image correlation (DIC) techniques, emphasizing their critical role in experimental research across various scientific domains. HS and UHS DIC have evolved significantly, driven by advancements in camera systems, image processing algorithms and experimental methodologies. These developments have opened new avenues for capturing and analysing dynamic events with unprecedented temporal and spatial detail, but not without introducing challenges such as optical distortions, motion blur and lighting issues that can affect measurement quality. This review advocates for standardized reporting practices in HS/UHS DIC methodologies to improve reproducibility and reliability across studies, drawing on guidelines from the International Digital Image Correlation Society (iDICs). Through a comprehensive analysis of over 150 articles, this review identifies key advancements in imaging technology and their application in six research domains: material characterization, test development, fracture mechanics, model validation, ballistic and explosive phenomena assessment and measurement uncertainties. Distinctions between two‐dimensional (2D) and stereo‐DIC applications are explored, offering insights into their practical implementation and trade‐offs. Good practices for HS/UHS DIC applications are proposed along with suggestions for future directions for this evolving field, highlighting the indispensable role of technological innovation in expanding the capabilities of optical metrology.

experimental mechanics↗

A study of real-world micrograph data quality and machine learning model robustness

Abstract Machine-learning (ML) techniques hold the potential of enabling efficient quantitative micrograph analysis, but the robustness of ML models with respect to real-world micrograph quality variations has not been carefully evaluated. We collected thousands of scanning electron microscopy (SEM) micrographs for molecular solid materials, in which image pixel intensities vary due to both the microstructure content and microscope instrument conditions. We then built ML models to predict the ultimate compressive strength (UCS) of consolidated molecular solids, by encoding micrographs with different image feature descriptors and training a random forest regressor, and by training an end-to-end deep-learning (DL) model. Results show that instrument-induced pixel intensity signals can affect ML model predictions in a consistently negative way. As a remedy, we explored intensity normalization techniques. It is seen that intensity normalization helps to improve micrograph data quality and ML model robustness, but microscope-induced intensity variations can be difficult to eliminate.

36 MATERIALS SCIENCE↗

Astronaut photography of the earth - Low cost images for resource exploration

Applications for photographs taken with handheld cameras by astronauts on the Space Shuttle are examined. The amount, types, and quality of photographs taken between 1981 and 1986 are described. Examples of these photographs and a portion of a map displaying the coverage of these photographs are presented. The possible use of handheld Space Shuttle photography in conjunction with Landsat mosaics for geologic exploration is discussed.

Wood, Charles A.↗

On the nature of models in remote sensing

An explicit framework can provide a better understanding of remote sensing models and their interrelationships. This framework distinguishes between the scene, which is real and exists on the ground, and the image, which is a collection of spatially arranged masurements drawn from the scene. The scene model generalizes and parameterizes the essential qualities of the scene. Scene models may be discrete, in which the scene model consists of discrete elements with boundaries, or continuous, in which matter and energy flows are taken to be continuous and there are no clear or sharp boundaries in the scene. In the discrete case, there are two possibilities for models: H- and L-resolution. In the H-resolution case, the resolution cells of the image are smaller than the elements, and thus the elements may be individually resolved. In the L-resolution case, the resolution cells are larger than the elements and cannot be resolved. Most canopy models are L-resolution, deterministic, and noninvertible in nature; image processing models, however, tend to be H-resolution, empirical, and invertible. This taxonomy helps add insight to the development of remote sensing theory and point the way to new, productive areas of research.

Strahler, A. H.↗

Revealing transient powder-gas interaction in laser powder bed fusion process through multi-physics modeling and high-speed synchrotron x-ray imaging

Laser powder bed fusion (LPBF) is an emerging metal additive manufacturing process. The gas-driven powder motions in laser powder bed fusion have significant influence on the build quality. However, the transient powder-gas interaction has not been well understood due to the challenges in quantitative experiment measurements. In this work, the powder-gas interaction for a single pulse laser illuminating on the powder bed is studied. We establish a multi-physics model to simulate the complex liquid/gas flow as well as the gas-driven powder motions, which is substantiated by high-speed synchrotron x-ray imaging. We identify and quantify four characteristic modes of powder-gas interaction in LPBF. The motion of a powder is controlled by one or multiple interaction modes collectively. As revealed by simulations and confirmed by experiments, powders can merge into the molten pool from its rim, be ejected at different divergence angles (powder spattering), or dive into the molten pool to cause significant molten pool fluctuation. Overall, our results provide insights toward the driving forces controlling the dynamic powder behavior, which pave the way for reducing structure defects during the build process.

36 MATERIALS SCIENCE↗

Satellites for long-term monitoring of inland U.S. lakes: The MERIS time series and application for chlorophyll-a

Lakes and other surface fresh waterbodies provide drinking water, recreational and economic opportunities, food, and other critical support for humans, aquatic life, and ecosystem health. Lakes are also productive ecosystems that provide habitats and influence global cycles. Chlorophyll concentration provides a common metric of water quality, and is frequently used as a proxy for lake trophic state. Here, we document the generation and distribution of the complete MEdium Resolution Imaging Spectrometer (MERIS; Appendix A provides a complete list of abbreviations) radiometric time series for over 2300 satellite resolvable inland bodies of water across the contiguous United States (CONUS) and more than 5,000 in Alaska. This contribution greatly increases the ease of use of satellite remote sensing data for inland water quality monitoring, as well as highlights new horizons in inland water remote sensing algorithm development. We evaluate the performance of satellite remote sensing Cyanobacteria Index (CI)-based chlorophyll algorithms, the retrievals for which provide surrogate estimates of phytoplankton concentrations in cyanobacteria dominated lakes. Our analysis quantifies the algorithms' abilities to assess lake trophic state across the CONUS. As a case study, we apply a bootstrapping approach to derive a new CI-to-chlorophyll relationship, ChlBS, which performs relatively well with a multiplicative bias of 1.11 (11%) and mean absolute error of 1.60 (60%). While the primary contribution of this work is the distribution of the MERIS radiometric timeseries, we provide this case study as a roadmap for future stakeholders' algorithm development activities, as well as a tool to assess the strengths and weaknesses of applying a single algorithm across CONUS.

MERIS timeseries↗

An Overview of Suomi NPP VIIRS Calibration Maneuvers

The first Visible Infrared Imager Radiometer Suite (VIIRS) instrument was successfully launched on-board the Suomi National Polar-orbiting Partnership (SNPP) spacecraft on October 28, 2011. Suomi NPP VIIRS observations are made in 22 spectral bands, from the visible (VIS) to the long-wave infrared (LWIR), and are used to produce 22 Environmental Data Records (EDRs) with a broad range of scientific applications. The quality of these VIIRS EDRs strongly depends on the quality of its calibrated and geo-located Sensor Date Records (SDRs). Built with a strong heritage to the NASA's EOS MODerate resolution Imaging Spectroradiometer (MODIS) instrument, the VIIRS is calibrated on-orbit using a similar set of on-board calibrators (OBC), including a solar diffuser (SD) and solar diffuser stability monitor (SDSM) system for the reflective solar bands (RSB) and a blackbody (BB) for the thermal emissive bands (TEB). On-orbit maneuvers of the SNPP spacecraft provide additional calibration and characterization data from the VIIRS instrument which cannot be obtained pre-launch and are required to produce the highest quality SDRs. These include multi-orbit yaw maneuvers for the characterization of SD and SDSM screen transmission, quasi-monthly roll maneuvers to acquire lunar observations to track sensor degradation in the visible through shortwave infrared, and a driven pitch-over maneuver to acquire multiple scans of deep space to determine TEB response versus scan angle (RVS). This paper pro-vides an overview of these three SNPP calibration maneuvers. Discussions are focused on their potential calibration and science benefits, pre-launch planning activities, and on-orbit scheduling and implementation strategies. Results from calibration maneuvers performed during the Intensive Calibration and Validation (ICV) period for the VIIRS sensor are illustrated. Also presented in this paper are lessons learned regarding the implementation of calibration spacecraft maneuvers on follow-on missions.

Butler, James J.↗

Pacific Northwest Health & Air Quality: Monitoring Trends in Air Quality During a Drought Case Study to Improve Public Health Response to Drought Threats

Recent studies have documented a correlation between air quality and drought in the United States, which has been linked with increased aerosols including airborne particulate matter (PM) during drought conditions. This study partnered with local health departments to evaluate trends in air quality in the Pacific Northwest during the evolution of drought conditions using aerosol optical depth (AOD) observations collected by NASA’s Moderate Resolution Imaging Spectroradiometer (MODIS) sensor aboard the Terra and Aqua satellites. These satellite data were analyzed in conjunction with ground-based PM2.5 and PM10 data sourced from the Environmental Protection Agency (EPA)’s network of ground-based monitors and the Standardized Precipitation Evapotranspiration Index (SPEI) drought index. Based on recommendations by local health departments, this study examined air quality trends between 2015 and 2022 in 12 counties within Oregon and Washington that reflected diversity in population density, drought exposure, rural and urban status, and data availability from EPA monitors. Overall, results indicated variation in relationships among drought, satellite, and ground-based air quality data across the study area. This study did not control for the impact of wildfire events on air quality and also did not investigate shorter SPEI aggregation periods, both of which are avenues for future research. This project supplemented research into links between drought and human health and provided health departments with an objective foundation from which they can communicate public health risks to local communities.

Abby Sgan↗

San Diego Water Resources: Monitoring Pollution Plumes due to Storm and Wastewater Runoff in the San Diego Bay and Tijuana River Estuary to Inform Water Quality Management

Stormwater and wastewater runoff are a large source of pollutant discharge along the southern California coast and are a major concern to the health of local communities and ecosystems. In partnership with the Tijuana River National Estuarine Research Reserve and the California Department of Environmental Quality, NASA DEVELOP utilized satellite imagery to visualize and analyze the water quality of the Tijuana Estuary and southern California coast after major storm and wastewater events. Using Landsat 8 Operational Land Imager (OLI) and Sentinel-2 Multispectral Instrument (MSI), we estimated the extent and severity of plumes released from the Tijuana River Estuary. We used remotely sensed turbidity to map the extent of plumes, and used remotely sensed turbidity, Chlorophyll-a (chl-a), and colored dissolved organic matter (CDOM) to quantify and visualize stormwater, wastewater, and mixed plumes from 2013 to 2022. Furthermore, remotely sensed CDOM, turbidity, and chl-a were validated with in-situ data from NOAA and the San Diego Public Utilities in the San Diego coastal area to evaluate the accuracy of water quality data derived from satellite imagery. End products of this project include maps of stormwater, wastewater, and mixed plumes, tables illustrating the average area, CDOM, turbidity, and chl-a of each plume type, and validation graphs between satellite and in-situ data sources. These end products informed the environmental management of the Tijuana River National Estuarine Research Reserve and the public beaches in San Diego.

Ethan Gates↗

350 ps Ultrafast room-temperature scintillation realized on CsPbBr 3 -based single crystals via Br 2 over-doping

Ultrafast scintillators are essential for next-generation radiation detection, positron emission tomography, and high-speed medical imaging. All-inorganic CsPbBr 3 perovskites are attractive candidates because of their high stopping power, and excellent optical quality, yet their long carrier lifetimes result in slow scintillation responses on the order of hundreds of nanoseconds. Here, we demonstrate that controlled over-doping with Br 2 produces CsPbBr 3.03 single crystals with sub-nanosecond scintillation at room temperature while preserving crystal quality. Single crystals grown by the Bridgman method exhibit high transparency and maintain the orthorhombic perovskite structure. Br 2 over-doping induces a slight lattice expansion (about 0.42% increase in unit-cell volume) while maintaining the orthorhombic perovskite phase and high optical transparency. Optical absorption reveals a slight redshift of the absorption edge after Br 2 introduction, indicating a modified defect landscape. Time-resolved photoluminescence and radioluminescence measurements show that Br 2 doping creates dense and efficient recombination centers that reduce the scintillation decay time from more than 100 ns in undoped crystals to 350 ps under 5.486 MeV α-particle excitation, and the scintillation decay time decreases by two orders of magnitude. The doped crystals also achieve a spatial resolution of 12 lp mm −1 in X-ray imaging. These results reveal a defect-engineering route for achieving ultrafast scintillation in halide perovskites and highlight the potential of Br 2 -modified CsPbBr 3 for fast timing applications.

Li, Zongxiao [Chinese Academy of Sciences (CAS), N↗

Lack of deleterious effect of slow-release sodium fluoride treatment on cortical bone histology and quality in osteoporotic patients

We evaluated the effects of intermittent slow-release sodium fluoride (SRNaF) and continuous calcium citrate therapy on cortical bone histology, reflection ultrasound velocity (material strength) and back-scattered electron image analysis (BEI) in 26 osteoporotic patients before and following therapy. All measurements were made on transiliac crest bone biopsies obtained before and following 2 years of therapy in each patient. For all 26 patients there were no significant changes in cortical bone histomorphometric parameters. In 15 patients in whom bone material quality was assessed by reflection ultrasound, there was no change in velocity (4000 +/- 227 SD to 4013 +/- 240 m/s). BEI disclosed no mineralization defects or the presence of woven bone. Mean atomic number (density) of bone increased slightly, but significantly (9.261 +/- 0.311 to 9.457 +/- 0.223, P = 0.031). While these changes are less marked than those observed for cancellous bone, they indicate that this form of therapy does not adversely affect cortical bone remodelling.

NASA Discipline Regulatory Physiology↗

Evaluation and Development of Phase Array Ultrasonic Testing (PAUT) System for Additively Manufactured Parts

This research focuses on the application of advanced ultrasonic testing techniques developed by The Phased Array Company (TPAC) for inspecting defects in additive manufacturing (AM) parts. Traditionally, X-ray computed tomography is the standard for inspecting AM components. Although, the long inspection and analysis time, along with relatively high cost make implementation difficult. Thus, an alternative nondestructive evaluation (NDE) approach is necessary to support quality assurance efforts within the field of AM. TPAC is recognized as a leader in ultrasonic testing innovation, deploying sophisticated algorithms such as Total Focusing Method (TFM) and Phased Wave Imaging (PWI) for ultrasonic data processing and interpretation. This work will explore how the TFM and PWI algorithms can assist defect detection within polymer AM parts. The AM field is seeking novel NDE methods to provide support within quality control and assurance efforts. Advanced ultrasonics inspection have the potential to fulfill this need.

99 GENERAL AND MISCELLANEOUS↗

Evaluation and Development of Phase Array Ultrasonic Testing (PAUT) System for Additively Manufactured Parts

This research focuses on the application of advanced ultrasonic testing techniques developed by The Phased Array Company (TPAC) for inspecting defects in additive manufacturing (AM) parts. Traditionally, X-ray computed tomography is the standard for inspecting AM components. Although, the long inspection and analysis time, along with relatively high cost make implementation difficult. Thus, an alternative nondestructive evaluation (NDE) approach is necessary to support quality assurance efforts within the field of AM. TPAC is recognized as a leader in ultrasonic testing innovation, deploying sophisticated algorithms such as Total Focusing Method (TFM) and Phased Wave Imaging (PWI) for ultrasonic data processing and interpretation. This work will explore how the TFM and PWI algorithms can assist defect detection within polymer AM parts. The AM field is seeking novel NDE methods to provide support within quality control and assurance efforts. Advanced ultrasonics inspection have the potential to fulfill this need.

36 MATERIALS SCIENCE↗

GLORIA - A Globally Representative Hyperspectral In Situ Dataset for Optical Sensing of Water Quality

The development of algorithms for remote sensing of water quality (RSWQ) requires a large amount of in situ data to account for the bio-geo-optical diversity of inland and coastal waters. The GLObal Reflectance community dataset for Imaging and optical sensing of Aquatic environments (GLORIA) includes 7,572 curated hyperspectral remote sensing reflectance measurements at 1 nm intervals within the 350 to 900 nm wavelength range. In addition, at least one co-located water quality measurement of chlorophyll a , total suspended solids, absorption by dissolved substances, and Secchi depth, is provided. The data were contributed by researchers affiliated with 59 institutions worldwide and come from 450 different water bodies, making GLORIA the de-facto state of knowledge of in situ coastal and inland aquatic optical diversity. Each measurement is documented with comprehensive methodological details, allowing users to evaluate fitness-for-purpose, and providing a reference for practitioners planning similar measurements. We provide open and free access to this dataset with the goal of enabling scientific and technological advancement towards operational regional and global RSWQ monitoring.

remote sensing of water quality↗