Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HUMIDITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Wickability-optimized textured liquid-desiccant air dehumidifiers for independent moisture management in energy-efficient buildings

Liquid-desiccant-based air conditioning systems are envisioned to enable independent humidity management, thereby improving the energy efficiency of future buildings. Existing liquid-desiccant-based air conditioning concepts, however, suffer from a poor liquid flow distribution deteriorating moisture removal rate. They are consequently flooded with the liquid-desiccant solution, which significantly degrades the energy efficiency of the dehumidification process. Here, in this work, the capillary forces and wickability effect of textured air dehumidifier surfaces are altered to minimize the liquid-desiccant flow rate of the fully wetted state, thereby transforming the physics of interfacial desiccant flow distribution. Consequently, the wickability-optimized air dehumidifier surface maximizes both moisture removal rate and dehumidification energy efficiency. It was interestingly found that the length scale of a textured air dehumidifier surface concept is optimized at an intermediate pattern density. Dry solid-air menisci appear at length scales exceeding the optimum pattern distance while the effective liquid–air interfacial area is reduced at smaller length scales, both of which degrade the moisture removal rate. At the optimum pattern density, the effective liquid–air interfacial area increases with the solution flow rate, thereby increasing the dehumidification rate. At a water vapor pressure potential of 3 kPa and a solution flow rate of 2.8 g/s, experimental results indicated a moisture removal rate of 0.16 g/m2-s for a textured surface concept with a capillary length scale of 3 mm, a 28% improvement compared with that of smooth-plate dehumidifier surfaces. A high moisture removal rate of the textured surface at a low desiccant flow rate led to a high thermal efficiency of 0.75 at a water vapor pressure potential of 5.6 kPa and a LiBr flow rate of 2.8 g/s. The insights gained from the present study accelerate the development of advanced textured surface concepts for next-generation liquid-desiccant-based air dehumidification systems offering independent humidity management for future energy-efficient buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Demonstrating non-isothermal vacuum membrane air dehumidification for efficient next-generation air conditioning

Vacuum membrane air dehumidification has gained significant interest in recent years as a highly efficient means of air dehumidification. Prior theoretical modeling work by the authors introduced the Active Membrane Energy Exchanger (AMX) concept, which combines active heat exchange and vacuum membrane dehumidification into one non-isothermal system, and found that it could outperform other air conditioning technologies under many conditions. However, no experimental literature exists on combining active heat exchangers and vacuum membrane dehumidification. Here, the goal of the present study is to evaluate the dehumidification (mass transfer) performance of the AMX concept relative to isothermal membrane dehumidification through three main methodologies: (1) membrane material-level characterization, (2) experimental prototype development and testing, and (3) computational fluid dynamics (CFD) simulations. The dense membranes used in this work showed up to a 40% increase in water vapor permeance at cooler temperatures, and the prototype system showed up to a 6% increase in humidity removal when the air was simultaneously cooled. Furthermore, the membrane module-integrated heat exchange tubes provided additional mixing and turbulence, leading to a 4–8% increase in humidity removal. The upper limit coefficient of performance was equal to approximately 2.2, necessitating advanced system designs to improve efficiency. This study is the first to highlight that combining the cooling and vacuum dehumidification processes can improve dehumidification performance.

30 DIRECT ENERGY CONVERSION↗

Experiments on a vapor compression air conditioner with liquid desiccants for efficient dehumidification

Buildings require air conditioning systems that not only cool and dehumidify supply air but also provide sufficient ventilation to ensure indoor air quality and occupant comfort. However, standard recirculation systems-which introduce about a 10 % to 20 % fraction of outdoor air-often fail to deliver air that is precisely cooled and dry, particularly because 80-90 % of the ventilation cooling load is latent. Mixing humid ventilation air with recirculated indoor air increases the energy and costs required to condition the air to comfortable levels. Dedicated outdoor air systems (DOASs) are designed to handle this latent dominated ventilation load and thus need to have efficient humidity removal. Many cooling cycles can perform this task. Here we describe a liquid desiccant DOAS, which combines a vapor compression cycle and a liquid desiccant absorber and desorber pair. We present its performance at 26 operating conditions and a thermodynamic model which can accurately predict the moisture removal efficiency. The model's performance predictions have a mean percentage error of 2.5 % and a coefficient of variation of the root mean square error of 7.5 %. We also compare the performance of this vapor-compression-coupled liquid desiccant system with a standard vapor compression system with the same components but no liquid desiccant. For the 26 conditions tested in this study, this comparison shows that adding liquid desiccants lowers the required evaporator cooling load by 21 %, allows for 25 % lower compressor volumetric capacity, and 25 % lower electricity use. Future work will leverage this model to quantify the reduction in annual electricity use across different climates, including the need for a standard vapor compression system to reheat the air during some of the year.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phytoextraction and phytoexcretion of Cd by the leaves of Tamarix smyrnensis growing on contaminated non-saline and saline soils

Phytoremediation and more specifically phytoextraction, is an alternative restoration strategy for the clean up of heavy metal contaminated soils. Phytoextraction can only be successful if suitable plant species colonize the contaminated area, extract the toxic substances and accumulate them in their above ground tissues. In this study, the salt cedar Tamarix smyrnensis that is a widespread salt-tolerant plant in the Mediterranean region has been investigated. A pot experiment is conducted with T. smyrnensis grown in polluted soil with 16 ppm of cadmium and at three different salt concentrations (0.0, 0.5, 3.0% NaCl) for a 10-week period. It took place in an open-air area with natural light, at ambient temperature and humidity in an effort to keep the plants under conditions as similar as possible to those in the field. However, care was taken not to let them be rained on. Temperature ranged from 19 to 50 deg. C with 33 and 21 deg. C being the average day and night temperature, respectively. Humidity ranged from 28% to 87% with a 13-14 h photoperiod. The specific aims of this work are to investigate the accumulation of cadmium via root uptake at different saline conditions and cadmium excretion through salt glands on the surface of the leaves as a probable detoxification mechanism of the plant. Furthermore, measurements of chlorophyll content, biomass, and shoot length are used to evaluate the potential of the plant for the removal of cadmium from contaminated saline and non-saline soils. The experimental data suggest that increased soil salinity results in an increase of the cadmium uptake by T. smyrnensis. Analysis of white salt crystals taken from glandular tissue confirmed the fact that this plant excretes cadmium through its salt glands on the surface of the leaves as a possible detoxification mechanism in order to resist metal toxicity. Excreted cadmium is again released into the environment and it is redeposited on the top soil. Furthermore, increased salinity results in an increased excretion of the metal on Tamarix leaf surface. The presence of metals usually affects negatively the plant health, but T. smyrnensis developed no visible signs of metal toxicity, only salt toxicity symptoms were observed. Cadmium usually decreases the chlorophyll content in plants; however, the amount of photosynthetic pigments of T. smyrnensis was found not to be affected. All the above points to the potential of T. smyrnensis for use in phytoremediation with the metal secretion from the leaves being a unique advantage that may change current phytoextraction practices.

60 APPLIED LIFE SCIENCES↗

Synthesis of porous organic cage CC3 via solvent modulated evaporation

We demonstrate a Humidity Modulated Solvent Evaporation (HMSE) approach to promote the nucleation and growth of CC3 crystals. This approach relies on the gradual evaporation of dichloromethane (solvent) from a diluted concentration of CC3 precursors deposited on aluminum foil. The slow solvent evaporation allowed enough time for the organization and formation of CC3 porous organic cage. The solvent diffusion rate was modulated by the relative humidity in the system. The slow kinetics implied during the development of CC3 phase, allowed the formation of CC3 crystals. HRTEM, SAED, SEM, and XRD patterns were used as pivotal characterization techniques to follow and confirm the formation of CC3 crystals.

porous organic cages, modulated evaporation, cryst↗

Analysis of heat and mass transfer potential of a dew-point cooling tower in different climatic conditions

In this study, the performance of the Dew-Point Cooling Tower (DPCT) was analyzed for different factors in a variety of climate conditions. For this purpose, a dedicated numerical model describing heat and mass transfer processes was developed and validated. The results of the numerical simulations allowed to analyze the potential of utilizing the heat and mass transfer process with the dew-point phenomenon for water cooling. It was established that the operational parameters that have a high impact on the performance of the DPCT are: inlet water temperature and inlet air humidity ratio. It was also established that DPCT achieves the highest COP and Specific Cooling Capacity for cold subtropical highland climates and that it achieves highest Wet-bulb Effectiveness for monsoon-influenced humid subtropical climates. In conclusion, the regions where all the efficiency factors achieved above-average values included warm, arid, and desert climates.

42 ENGINEERING↗

Modeling and simulation of CO 2 capture using semipermeable elastic microcapsules

Very high rates of CO2 absorption have been demonstrated using semipermeable microcapsules filled with environmentally benign sodium carbonate solutions (Vericella et al., Nature communications 6, 2015). However, such capsules have also exhibited several traits, including water loss/uptake, elastic swelling and buckling, and precipitation of solids, which make them more complicated to engineer as a carbon capture material. To address this, a mechanistic model for mass transfer and chemical reaction has been developed, which accounts for these behaviors, and can be used as a predictive tool to explore capsule performance under different CO2 capture scenarios. The model uses a modified film theory to describe CO2 and H2O mass transfer rates, a concentration based description of vapor-liquid-solid equilibrium inside the capsule, and an elastic description of the capsule shell. Model predictions compare favorably to literature data for precipitating carbonates, as well as recent data for microcapsule CO2 absorption. The model was used to assess practical issues of capsule water transfer during a temperature swing CO2 absorption/desorption cycle. Model predictions indicate that capsules filled with high weight percent, precipitating sodium carbonate solution could be significantly or completely dehydrated during CO2 absorption. Subsequent rehydration of lean capsules at elevated temperature showed strong sensitivity to both gas humidity, and capsule shell elasticity.

97 MATHEMATICS AND COMPUTING↗

On the importance of the heat and mass transfer resistances in internally-cooled liquid desiccant dehumidifiers and regenerators

Liquid desiccant heat and mass exchangers are a promising technology for efficient humidity control in buildings. Many researchers have investigated these exchangers, often using numerical models to predict their performance. However, there is a lack of information in the literature on the magnitude of the heat and mass transfer resistances, both for the dehumidifier (which absorbs moisture from the air) and the regenerator (which heats the liquid desiccant to re-concentrate it). This article focuses on internally-cooled, 3-fluid exchangers in a parallel plate geometry. Water heats or cools a desiccant across a plate, and the desiccant absorbs or releases water into an airstream through a membrane. A sensitivity analysis was used to estimate the importance of each of the heat and mass transfer resistances (air, membrane, desiccant, plate, water), and how it changes with different design geometries. The results show that, for most designs, the latent and sensible heat transfer of the dehumidifier is dominated by the air mass transfer resistance and air heat transfer resistance, respectively. The air mass transfer resistance is also important for the regenerator, but much less so; the change in the desiccant equilibrium humidity ratio due to a change in either temperature or desiccant mass fraction is much higher at the regenerator's higher temperatures. This increases the importance of (1) getting heat from the water to the desiccant/membrane interface, and (2) diffusing salt ions quickly away from the desiccant/membrane interface. The membrane heat transfer and water heat transfer resistances were found to be the least important. These results can help inform decisions about what simplifying assumptions to make in numerical models, and can also help in designing these exchangers by understanding which resistances are most important.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Oxidation of porous stainless steel supports for metal-supported solid oxide fuel cells

Here, oxidation behavior of porous P434L ferritic stainless steel, used for the fabrication of metal-supported solid oxide fuel cells (MS-SOFC), is studied under anodic and cathodic atmospheres. Temperature- and atmosphere-dependence is determined for as-sintered and pre-oxidized stainless steel. Pre-oxidation reduced the long-term oxidation rate. For pre-oxidized samples, the oxidation rate in air exceeds that in humid hydrogen for temperatures above 700 °C. The influence of PrOx, LSCF-SDC, and Ni-SDC coatings is also examined. The coatings do not dramatically impact oxide scale growth. Oxidation in C-free and C-containing anodic atmospheres is similar. Addition of CO 2 , CH 4 , and CO to humidified hydrogen to simulate ethanol reformate does not significantly impact oxidation behavior. Cr transpiration in humid air is greatly reduced by the PrOx coating, and a PrCrO 3 reaction product is observed throughout the porous structure. A dense and protective chromia-based scale forms on steel samples during oxidation in all conditions. A thin silica enriched oxide layer also forms at the metal-scale interface. In general, the oxidation behavior at 700 °C is found to be acceptable.

25 ENERGY STORAGE↗

Experimental measurements of fuel and water crossover in an active DMFC

This work measured polarization curves as well as the high-frequency resistance of active direct methanol fuel cell (DMFC) operates at around 80 °C with active controls of temperature, methanol concentration, airflow rate, and relative humidity. The relative humidity of the air did not have noticeable impacts on the fuel cell unless the operating temperature was near the evaporation temperature of water (100 °C). The hydrophobic water management layer (WML) between the membrane electrode assembly (MEA) and cathode air channel increases the mass transfer resistance and improves the water retention in MEA. Adding a WML increased the peak power density, decreased the ohmic resistance, and improved the fuel efficiency of the fuel cell, especially when it operated near 100 °C. This study also quantitatively measured methanol and water crossover as well as the fuel efficiency at different operating currents. The fuel efficiency increased significantly with the increase of the current density. Using a hydrophobic fuel management layer (FML) between the anode fuel channel and MEA reduced the fuel and water crossover rates and increased the ohmic resistance due to the decrease of the water content of the Nafion membrane. The FML improved fuel efficiency by reducing the methanol crossover. The combination of the FML and WML enabled the steady operation of DMFC using highly concentrated methanol solutions (up to 75 wt%).

08 HYDROGEN↗

Separate sensible and latent cooling: Carnot limits and system taxonomy

Energy efficiency and thermal comfort can be improved by independent control of temperature and humidity. In recent work, an emerging class of cooling systems known as separate sensible and latent cooling (SSLC) systems have demonstrated 14 to 47% energy savings, while simultaneously providing better comfort control than conventional air conditioning. In this work, SSLC is defined as using two or more cooling processes with unequal sensible heat ratio (SHR) to control temperature and humidity independently and dynamically. Fundamental efficiency limits of SSLC systems are developed for the first time, demonstrating that the Carnot efficiency for SSLC is higher than that of conventional systems. It is revealed that SSLC has particularly high potential for moderate outdoor temperatures, high sensible building loads, and drier indoor conditions. Additionally, this work proposes a classification scheme for SSLC systems, revealing an enormous number of feasible cycle permutations. This provides a framework for the important research task of developing SSLC systems that will save energy, be practical to construct, and be controllable.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaporation from thin porous Coatings: Pore size effects and predictive equation for homogeneous coatings

Evaporation of small water droplets on solids is hindered because surface tension pulls the droplet into a spherical cap that has a small perimeter. Our solution is to coat a solid with a very thin, porous layer into which the droplet flows to create a large-area disk with concomitant high rate of evaporation. We investigate evaporation by varying factors that have not been previously considered: pore size and distribution, contact angle, temperature, and relative humidity (RH). A larger pore size resulted in faster evaporation, which we explain through faster transport within the coating. Even faster evaporation occurred for a bilayer structure with small particles on the air side and larger particles on the solid side. Further, the water advancing contact angle had an insignificant effect in the range from < 10° through to 60°. Our results for different pore sizes, temperature, humidity, and contact angle all collapse onto a single curve when appropriately normalized. This validates an equation that can be used for the evaporation from a homogeneous coating that depends only one empirical factor and the droplet volume. Since the volume is often user-controlled, we envisage that this equation can be used to predict evaporation and guide design of fast-drying coatings.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Life-cycle cost-benefit analysis of a novel self-heating pavement made from coal-derived solid carbon

Winter weather events challenge the safety, efficiency, and sustainability of roadway networks, particularly road bridges vulnerable to climate impacts. Although effective, conventional de-icing methods incur high expenses and cause significant environmental contamination. To address these longstanding issues, a low-cost novel coal-derived carbon enabled smart pavement (CDC-SP) de-icing system was developed, aiming to alleviate traffic delays, severe corrosion, compromised safety, and environmental pollution. However, the economic performance of CDC-SP has not been quantified to guide decision-making. To this end, this paper presents a Life-Cycle Cost-Benefit Analysis (LCCBA) to assess the economic feasibility of the CDC-SP de-icing system for road bridges in five representative urban and rural areas across cool humid and cold humid climate zones. Given the variations and uncertainties of several factors that determine the costs and benefits, a sensitivity analysis was conducted to determine the system’s economic reliability. Additionally, a Monte Carlo simulation (MCS) was performed to quantify the impacts of important factors and identify the most beneficial scenarios. Furthermore, the CDC-SP de-icing systems have demonstrated substantial economic benefits and short payback periods, showing great applicability for rural and urban road bridges with different service levels across multiple climate zones as compared to conventional de-icing methods.

36 MATERIALS SCIENCE↗

Atomic force microscopy monitoring of subcritical slow crack growth in soda lime silicate glass

Prediction of brittle fracture in silicate glasses requires a fundamental understanding of slow crack growth rates, far below the critical stress intensity (K IC ) of the material. Here, in this study, atomic force microscopy (AFM) was used to characterize slow crack propagation in soda lime silicate glasses. Using large-sample AFM systems with specialized tips and scanners, fractures less than 20 nm wide were measured as a function of relative humidity (RH). The results were found to be sensitive to the type of AFM tip used and to the dryness of the surface. Continuous scanning and image capture over several days allowed the determination of the crack tip velocity. The dependance of crack tip velocity on RH was measured by enclosing the sample and AFM head in a humidity-controlled chamber. The crack tip velocity was measured as low 4.0×10 -12 m/s at 15 % RH and as high as 3.7×10 -10 m/s at 40 % RH. Overall crack growth was smooth during the AFM scan. Additionally, recession of the crack tip was noted as the sample dried, indicating crack tip closure may be occurring. Further studies on alternative compositions will provide details on subcritical fracture processes in a range of different environmental conditions.

Atomic force microscopy↗

Breakage mechanics for granular materials in surface-reactive environments

It is known that the crushing behaviour of granular materials is sensitive to the state of the fluids occupying the pore space. Here, in this work, a thermomechanical theory is developed to link such macroscopic observations with the physico-chemical processes operating at the microcracks of individual grains. The theory relies on the hypothesis that subcritical fracture propagation at intra-particle scale is the controlling mechanism for the rate-dependent, water-sensitive compression of granular specimens. First, the fracture of uniaxially compressed particles in surface-reactive environments is studied in light of irreversible thermodynamics. Such analysis recovers the Gibbs adsorption isotherm as a central component linking the reduction of the fracture toughness of a solid to the increase of vapour concentration. The same methodology is then extended to assemblies immersed in wet air, for which solid-fluid interfaces have been treated as a separate phase. It is shown that this choice brings the solid surface energy into the dissipation equations of the granular matrix, thus providing a pathway to (i) integrate the Gibbs isotherm with the continuum description of particle assemblies and (ii) reproduce the reduction of their yield strength in presence of high relative humidity. The rate-effects involved in the propagation of cracks and the evolution of breakage have been recovered by considering non-homogenous dissipation potentials associated with the creation of surface area at both scales. It is shown that the proposed model captures satisfactorily the compression response of different types of granular materials subjected to varying relative humidity. This result was achieved simply by using parameters based on the actual adsorption characteristics of the constituting minerals. The theory therefore provides a physically sound and thermodynamically consistent framework to study the behaviour of granular solids in surface-reactive environments.

36 MATERIALS SCIENCE↗

Characterisation and heat treatment of chloride-contaminated and humidified PuO2 samples

To mimic the reactions that have occurred between plutonium dioxide (PuO2) and degraded polyvinyl chloride during prolonged storage, batches of PuO2 powders with varying specific surface area (4-38m2 g1) were exposed to dry hydrogen chloride gas forming a surface-sorbed exchangeable chloride species that was readily leached by dilute caustic solution. One batch was also humidified under a 95% relative humidity atmosphere. Heat treatment at temperatures between 100 and 950 C steadily reduced the leachable chloride content at least when the initial leachable chloride surface coverage was calculated to be > 0.5 monolayer (ML). Variations between samples are attributed to differences in surface area as well as production route and period of interim storage in air or humidified atmospheres. The data are consistent with surface species and reactions proposed in the literature for HCl adsorption on to TiO2. This indicates that it is interactions between hydrogen chloride/chloride and water/hydroxyl species on the PuO2 surface that are key to understanding the behaviour of these materials when heated in a furnace. These data will inform the design of a future thermal stabilisation process for chloride-contaminated PuO2.

Sutherland-Harper, Sophie↗

Synthesis and characterization of super occluded LiCl-KCl in zeolite-4A as a chloride salt waste form intermediate

Here, this paper reports the hygroscopic properties of eutectic LiCl-KCl after absorption into zeolite-4A, up to salt loadings of 75 wt%. Samples of the salt occluded zeolite were hydrated in a humidity chamber at constant temperature and relative humidity for up to 100 h. At up to 45 wt% salt loading, the un-occluded phase of salt consisted primarily of NaCl, which forms when the Na + ions present in the zeolite framework exchange with Li + and K + ions from the eutectic LiCl-KCl. This results in minimal water absorption and corrosion of contacted stainless steel. At greater than 45 wt% salt loading, water absorption and corrosion progressively worsened. The mixture has a significant amount of excess LiCl-KCl, making it highly hygroscopic. This study reveals an option for the intermediate treatment of waste salt from spent nuclear fuel electrorefiners that could facilitate it to be stored in a non-inert atmosphere for extended periods of time before final conversion into a permanent waste form.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗