Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Gas sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Operation of the “Small” BioAMS spectrometers at CAMS: Past and future prospects

A summary of results from the solid samples run on our compact 1 MV AMS system over its 13.5 years of operation is presented. On average 7065 samples per year were measured with that average dropping to 3278 samples per year following the deployment of our liquid sample capability. Although the dynamic range of our spectrometer is 4.5 orders in magnitude, most of the measured graphitic samples had 14 C/C concentrations between 0.1 and 1 modern. Furthermore, the measurements of our ANU sucrose standard followed a Gaussian distribution with an average of 1.5082 ± 0.0134 modern. The LLNL biomedical AMS program supported many different types of experiments, however, the large majority of samples measured were derived from animal model systems. We have transitioned all of our biomedical AMS measurements to the recently installed 250 kV SSAMS instrument with good agreement compared in measured 14C/C isotopic ratios between sample splits. We then present results from replacement of argon stripping gas with helium in the SSAMS with a 22% improvement in ion transmission through the accelerator and high-energy analyzing magnet.

14C↗

High resolution measurements reveal abiotic and biotic mechanisms of elevated nitric oxide emission after wetting dry soil

Wetting dry soil triggers emission of nitric oxide (NO), which can harm air quality and influence ecosystem N balance. NO released after wetting may be derived from two primary mechanisms: (1) abiotic decomposition of nitrite (NO 2 -) present in the dry soil and (2) biologically-mediated production of NO. The relative contributions of these mechanisms to NO emission are challenging to partition. To differentiate the two mechanisms, we made continuous observations of NO emission from a range of soils that varied in texture, pH, and exchangeable cations. Additionally, we coupled NO gas exchange measurements with automated, non-destructive high-resolution sampling of inorganic N species via microdialysis. We identified two distinct phases of NO production (1) an initial phase that reached its maximum less than 30 min after rewetting; and (2) a second phase lasting up to 36 h. The magnitude of the initial phase of NO production was correlated with the initial nitrous acid concentration (calculated from NO 2 - concentrations and soil pH) and soil exchangeable calcium. The second phase of NO emission coincided with a peak in NO 2 - that preceded NO 3 - accumulation. Together, these results suggest that NO emissions following wetting are defined by an initial pulse of abiotic NO formation mediated by soil acidity at mineral surfaces, followed by a prolonged pulse of NO emission driven by a lag between the biological processes of ammonia oxidation and nitrite oxidation. These results can inform mechanistic models of NO emissions from soils to improve predictions of the terrestrial N cycle and atmospheric chemistry.

54 ENVIRONMENTAL SCIENCES↗

Influence of Thermal Annealing on Free Carrier Concentration in (GaN) 1– x (ZnO) x Semiconductors

It has been previously demonstrated that the efficiency of (GaN) 1–x (ZnO) x semiconductors for solar water splitting can be improved by thermal annealing, though the origin of this improvement was not resolved. In the present work, it is shown that annealing reduces the free carrier (electron) concentration of (GaN) 1–x (ZnO) x . The time-, temperature-, and atmosphere-dependent changes were followed through two simple techniques: indirect diffuse reflectance measurements from 0.5 to 3.0 eV which show very high sensitivity to the free carrier response at the lowest energies and EPR measurements which directly probe the number of unpaired electrons. For the thermal annealing of investigated compositions, it is found that temperatures of 250 °C and below do not measurably change the free carrier concentration, a gradual reduction of the free carrier concentration occurs over a time period of many hours at 350 °C, and the complete elimination of free carriers happens within an hour at 550 °C. These changes are driven by an oxidative process which is effectively suppressed under actively reducing atmospheres (H 2 , NH 3 ) but which can still occur under nominally inert gases (N 2 , Ar). Surprisingly, it is found that the N 2 gas released during thermal oxidation of (GaN) 1–x (ZnO) x samples remains trapped within the solid matrix and is not expelled until temperatures of about 900 °C, a result directly confirmed through neutron pair-distribution fuction (PDF) measurements which show a new peak at the 1.1 Å bond length of molecular nitrogen after annealing. Preliminary comparative photoelectrochemical (PEC) measurements of the influence of free carrier concentration on photoactivity for water oxidation were carried out for a sample with x = 0.64. Samples annealed to eliminate free carriers exhibited no photoactivity for water oxidation, while a complex dependence on carrier concentration was observed for samples with intermediate free carrier concentrations. The methods demonstrated here provide an important approach for quantifying (and controlling) the carrier concentrations of semiconductors which are only available in the form of loose powders, as is commonly the case for oxynitride compounds.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The multiplexed chemical kinetic photoionization mass spectrometer: A new approach to isomer-resolved chemical kinetics

We have developed a multiplexed time- and photon-energy-resolved photoionization mass spectrometer for the study of the kinetics and isomeric product branching of gas phase, neutral chemical reactions. The instrument utilizes a side-sampled flow tube reactor, continuously tunable synchrotron radiation for photoionization, a multimass double-focusing mass spectrometer with 100% duty cycle, and a time- and position-sensitive detector for single ion counting. This approach enables multiplexed, universal detection of molecules with high sensitivity and selectivity. In addition to measurement of rate coefficients as a function of temperature and pressure, different structural isomers can be distinguished based on their photoionization efficiency curves, providing a more detailed probe of reaction mechanisms. The multiplexed three-dimensional data structure (intensity as a function of molecular mass, reaction time, and photoionization energy) provides insights that might not be available in serial acquisition, as well as additional constraints on data interpretation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Improvements to a cryosystem to observe ice nucleating in a variable pressure scanning electron microscope

The variable pressure scanning electron microscope (VPSEM) has expanded the scope of the SEM to allow the imaging of dynamic, electrically insulating systems. The use of water vapor as the imaging gas present in the chamber allows the successful imaging of hydrated samples. As awareness of the system capabilities becomes more well known, greater pressure has been put onto the microscopist to push the boundaries of both temperature and resolution for the study of diverse hydrated samples whose dynamics may not occur at the usual room temperatures in a VPSEM. In this article we discuss the stages in the development of a cryosystem that has led to the successful observation of the nucleation of ice from a solution in situ. This investigation also leads to further possibilities of imaging hydrated samples in the little explored temperature range of 188-238 K (from -85 to-35 deg. C). This study includes the exploration of how the temperature of various surfaces inside the microscope will change the system's ability to keep a sample hydrated or in its native state.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A battery-operated, stabilized, high-energy pulsed electron gun for the production of rare gas excimers

We report on the design of a new type of hot-filament electron gun delivering fairly high current (a few hundreds of {mu} A) at high voltage (up to 100 kV) in continuous or pulsed mode. Its novel features are that the filament is heated by means of a pack of rechargeable batteries floated atop the high-voltage power supply in order to get rid of bulky isolation transformers, and that the filament current and, hence, the electron gun current, is controlled by a feedback circuit including a superluminescent diode decoupled from the high voltage by means of an optical fiber. This electron gun is intended for general purposes, although we have especially developed it to meet the needs of our experiment on the infrared emission spectroscopy of rare gas excimers. Our experiment requires that the charge injection into the sample is pulsed and constant and stable in time. The new electron gun can deliver several tens of nC per pulse of electrons of energy up to 100 keV into the sample cell. The new design also eliminates ripples in the emission current and ensures up to 12 h of stable performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Trapping ultracold gases near cryogenic materials with rapid reconfigurability

We demonstrate an atom chip trapping system that allows the placement and high-resolution imaging of ultracold atoms within microns from any ≲100 μm-thin, UHV-compatible material, while also allowing sample exchange with minimal experimental downtime. The sample is not connected to the atom chip, allowing rapid exchange without perturbing the atom chip or laser cooling apparatus. Exchange of the sample and retrapping of atoms has been performed within a week turnaround, limited only by chamber baking. Moreover, the decoupling of sample and atom chip provides the ability to independently tune the sample temperature and its position with respect to the trapped ultracold gas, which itself may remain in the focus of a high-resolution imaging system. As a first demonstration of this system, we have confined a 700-nK cloud of 8 × 10{sup 4} {sup 87}Rb atoms within 100 μm of a gold-mirrored 100-μm-thick silicon substrate. The substrate was cooled to 35 K without use of a heat shield, while the atom chip, 120 μm away, remained at room temperature. Atoms may be imaged and retrapped every 16 s, allowing rapid data collection.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Modeling atomically mixed graded density impactors

Graded density impactors (GDIs) are multi-material composite impactors used in gas gun experiments to tailor the drive conditions imparted to a sample test material. Previous graded density impactors generally rely on thin, but discrete, layers of different materials. The thinner and the greater number of layers will result in smoother compression. Taken to the limit of very thin layers would be pure material 1 at one surface, such as the front surface of an impactor, smoothly transitioning at the atomic scale to pure material 2 on the back surface. Such an impactor can initially shock, then smoothly compresses a material during a dynamic experiment. This type of experiment can serve to explore a larger region of thermodynamic space than a single or even multi-shock experiments. An overview of how graded density impactors are made is reviewed and sample results are given. Additionally, a strategy for modeling these kinds of impactors is presented. The length scales of constituent mixing are given from the experimental build through electrochemical-deposition. Equation of state models for pure constituents and their subsequent mixtures are presented. It is demonstrated that the time scales for pressure and temperature equilibration, for atomically mixed GDIs, are short enough to be a justifiable closure for the resulting multiphase flow. Furthermore, we present simulation results of dynamic shock followed by a ramp compression, utilizing a silver/gold graded density impactor, onto a tantalum sample.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A COLD NEPTUNE-MASS PLANET OGLE-2007-BLG-368Lb: COLD NEPTUNES ARE COMMON

We present the discovery of a Neptune-mass planet OGLE-2007-BLG-368Lb with a planet-star mass ratio of q = [9.5 +- 2.1] x 10{sup -5} via gravitational microlensing. The planetary deviation was detected in real-time thanks to the high cadence of the Microlensing Observations in Astrophysics survey, real-time light-curve monitoring and intensive follow-up observations. A Bayesian analysis returns the stellar mass and distance at M{sub l} = 0.64{sup +0.21}{sub -0.26} M{sub sun} and D{sub l} = 5.9{sup +0.9}{sub -1.4} kpc, respectively, so the mass and separation of the planet are M{sub p} = 20{sup +7}{sub -8} M{sub +} and a = 3.3{sup +1.4}{sub -0.8} AU, respectively. This discovery adds another cold Neptune-mass planet to the planetary sample discovered by microlensing, which now comprises four cold Neptune/super-Earths, five gas giant planets, and another sub-Saturn mass planet whose nature is unclear. The discovery of these 10 cold exoplanets by the microlensing method implies that the mass ratio function of cold exoplanets scales as dN{sub pl}/dlog q {proportional_to} q {sup -0.7+}-{sup 0.2} with a 95% confidence level upper limit of n < -0.35 (where dN{sub pl}/dlog q {proportional_to} q{sup n} ). As microlensing is most sensitive to planets beyond the snow-line, this implies that Neptune-mass planets are at least three times more common than Jupiters in this region at the 95% confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

Stellar s-process neutron capture cross sections on 78,80,84,86 Kr determined via activation, atom trap trace analysis and decay counting

We present a detailed account of neutron capture experiments of astrophysical relevance on 78,80,84,86 Kr (n, γ) reactions at the border between weak and main s process. The experiments were performed with quasi-Maxwellian neutrons from the Liquid-Lithium Target (LiLiT) and the mA-proton beam at 1.93 MeV (2-3 kW) of the Soreq Applied Research Accelerator Facility (SARAF). The setup yields high-intensity approximate to 40 keV quasi-Maxwellian neutrons (3-5 x10 10 n/s) closely reproducing the conditions of s-process stellar nucleosynthesis. A sample of 100 mg of atmospheric, pre-nuclear-age Kr gas contained in a Ti spherical shell was activated in the LiLiT neutron field. The abundances of long-lived Kr isotopes ( 81,85g Kr) were measured by atom counting via atom trap trace analysis (ATTA) at Argonne National Laboratory and low-level counting (LLC) at University of Bern. This work is the first measurement of a nuclear cross section using atom counting via ATTA. The activities of short-lived Kr isotopes ( 79,85m,87 Kr) were measured by gamma-decay counting with a high-purity germanium detector. Maxwellian-averaged cross sections for s-process thermal energies are extracted. By comparison to reference values, our nucleosynthesis network calculations show that the experimental cross sections have a strong impact on calculated abundances of krypton and neighboring nuclides, in some cases improving agreement between theory and observations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Prospects for Constraining Dark Energy withFuture X-ray Cluster Gas Mass Fraction Measurements

We examine the ability of a future X-ray observatory, with capabilities similar to those planned for the Constellation-X mission, to constrain dark energy via measurements of the cluster X-ray gas mass fraction, fgas. We find that fgas measurements for a sample of {approx}500 hot (kT{approx}> 5keV), X-ray bright, dynamically relaxed clusters, to a precision of {approx}5 percent, can be used to constrain dark energy with a Dark Energy Task Force (DETF; Albrecht et al. 2006) figure of merit of 20-50. Such constraints are comparable to those predicted by the DETF for other leading, planned 'Stage IV' dark energy experiments. A future fgas experiment will be preceded by a large X-ray or SZ survey that will find hot, X-ray luminous clusters out to high redshifts. Short 'snapshot' observations with the new X-ray observatory should then be able to identify a sample of {approx}500 suitably relaxed systems. The redshift, temperature and X-ray luminosity range of interest has already been partially probed by existing X-ray cluster surveys which allow reasonable estimates of the fraction of clusters that will be suitably relaxed for fgas work to be made; these surveys also show that X-ray flux contamination from point sources is likely to be small for the majority of the targets of interest. Our analysis uses a Markov Chain Monte Carlo method which fully captures the relevant degeneracies between parameters and facilities the incorporation of priors and systematic uncertainties in the analysis. We explore the effects of such uncertainties, for scenarios ranging from optimistic to pessimistic. We conclude that the fgas experiment offers a competitive and complementary approach to the best other large, planned dark energy experiments. In particular, the fgas experiment will provide tight constraints on the mean matter and dark energy densities, with a peak sensitivity for dark energy work at redshifts midway between those of supernovae and baryon acoustic oscillation/weak lensing/cluster number counts experiments. In combination, these experiments should enable a precise measurement of the evolution of dark energy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CAPER as central and crucial facility to support R/D with tritium at TLK

The CAPER facility at TLK (Tritium Laboratory Karlsruhe) originally devoted to Research/Development on tokamak exhaust processing has been significantly upgraded over the last years. Beside new programs on highly tritiated water, CAPER is presently largely used to support satellite experiments, mainly those dedicated to research on advanced analytics. Mutation from Research/Development to part of the TLK tritium infrastructure necessitated new features to be installed in order to facilitate and optimize tritiated mixtures preparation and sample filling, and to enable satellites experiments to discharge their waste gas to CAPER for clean-up. This paper presents recent CAPER mutations to become a central and key facility at TLK. (authors)

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Analysis of chemical warfare agents by gas chromatography-mass spectrometry: methods for their direct detection and derivatization approaches for the analysis of their degradation products

Abstract Chemical warfare agents (CWAs) are unarguably one of the most feared toxic substances produced by mankind. Their inception in conventional warfare can be traced as far back as the Middle Ages but their full breakthrough as central players in bellic conflicts was not realized until World War I. Since then, more modern CWAs along with efficient methods for their manufacture have emerged and violently shaped the way modern warfare and diplomatic relations are conducted. Owing to their mass destruction ability, counter methods to mitigate their impact appeared almost immediately on par with their development. These efforts have focused on their efficient destruction, development of medical countermeasures and their detection by modern analytical chemistry methods. The following review seeks to provide the reader with a broad introduction on their direct detection by gas chromatography-mass spectrometry (GC-MS) and the various sample derivatization methods available for the analysis of their degradation products. The review concentrates on three of the main CWA classes and includes the nerve agents, the blistering agents and lastly, the incapacitating agents. Each section begins with a brief introduction of the CWA along with discussions of reports dealing with their detection in the intact form by GC-MS. Furthermore, as products arising from their degradation carry as much importance as the agents themselves in the field of forensic analysis, the available derivatization methods of these species are presented for each CWA highlighting some examples from our lab in the Forensic Science Center at the Lawrence Livermore National Laboratory.

Valdez, Carlos A.↗

Reduced-Order Model for the Geochemical Impacts of Carbon Dioxide, Brine and Trace Metal Leakage into an Unconfined, Oxidizing Carbonate Aquifer (V.2.1)

The National Risk Assessment Partnership (NRAP) consists of 5 U.S DOE national laboratories collaborating to develop a framework for predicting the risks associated with carbon sequestration. The approach taken by NRAP is to divide the system into components, including injection target reservoirs, wellbores, natural pathways including faults and fractures, groundwater and the atmosphere. Next, develop a detailed, physics and chemistry-based model of each component. Using the results of the detailed models, develop efficient, simplified models, termed reduced order models (ROM) for each component. Finally, integrate the component ROMs into a system model that calculates risk profiles for the site. This report details the development of the Groundwater Geochemistry ROM for the Edwards Aquifer at PNNL. The Groundwater Geochemistry ROM for the Edwards Aquifer uses a Wellbore Leakage ROM developed at LANL as input. The detailed model, using the STOMP simulator, covers a 5 x 8-km area of the Edwards Aquifer near San Antonio, Texas. The model includes heterogeneous hydraulic properties, and equilibrium, kinetic and sorption reactions between groundwater, leaked CO 2 gas, brine, and the aquifer carbonate and clay minerals. Latin Hypercube sampling was used to generate 1024 samples of input parameters. For each of these input samples, the STOMP simulator was used to predict the flux of CO 2 to the atmosphere, and the volume, length and width of the aquifer where pH was less than the MCL standard, and TDS, arsenic, cadmium and lead exceeded MCL standards. In order to decouple the Wellbore Leakage ROM from the Groundwater Geochemistry ROM, the response surface was transformed to replace Wellbore Leakage ROM input parameters with instantaneous and cumulative CO 2 and brine leakage rates. The most sensitive parameters proved to be the CO 2 and brine leakage rates from the well, with equilibrium coefficients for calcite and dolomite, as well as the number of illite and kaolinite sorption sites proving to be of secondary importance. The Groundwater Geochemistry ROM was developed using nonlinear regression to fit the response surface with a quadratic polynomial. The goodness of fit was excellent for the CO 2 flux to the atmosphere, and very good for predicting the volumes of groundwater exceeding the pH, TDS, As, Cd and Pb threshold values.

carbon sequestration↗

Precision Gas System Isotope Analyzer (PGSISO) Instrument Handbook

The PGSISO is a combination of several systems in series; (1) gas processing components that pressurize and prevent liquid water entering the sample stream, and (2) the Spectronus FTIR spectrometer, which measures continuous CO 2 , 12 CO 2 , 13 CO 2 , CH 4 , CO, N 2 O, and H 2 O. The Spectronus analyzer has been developed by the Centre for Atmospheric Chemistry at the University of Wollongong, Australia, and manufactured by Ecotech Pty Ltd, headquartered in Melbourne, Australia.

54 ENVIRONMENTAL SCIENCES↗

HIGHMASS—HIGH H I MASS, H I -RICH GALAXIES AT Z ~ 0: COMBINED H I AND H 2 OBSERVATIONS

We present resolved H I and CO observations of three galaxies from the HIghMass sample, a sample of H I -massive (M HI >10 10 M ⊙ ), gas-rich (M HI in the top 5% for their M &ast; ) galaxies identified in the ALFALFA survey. Despite their high gas fractions, these are not low-surface-brightness galaxies and have typical specific star formation rates (SFR/M &ast; ) for their stellar masses. The three galaxies have normal SFRs for their H 2 masses, but unusually short star formation efficiency scale lengths, indicating that the star formation bottleneck in these galaxies is in the conversion of H I to H 2 , not in converting H 2 to stars. In addition, their dark matter spin parameters (λ) are above average, but not exceptionally high, suggesting that their star formation has been suppressed over cosmic time but is now becoming active, in agreement with prior Hα observations.

79 ASTRONOMY AND ASTROPHYSICS↗

The Grism Lens-Amplified Survey from Space (GLASS). X. Sub-kiloparsec Resolution Gas-phase Metallicity Maps at Cosmic Noon behind the Hubble Frontier Fields Cluster MACS1149.6+2223

We combine deep Hubble Space Telescope grism spectroscopy with a new Bayesian method to derive maps of gas-phase metallicity for 10 star-forming galaxies at high redshift (1.2≲z≲2.3). Exploiting lensing magnification by the foreground cluster MACS1149.6+2223, we reach sub-kiloparsec spatial resolution and push the limit of stellar mass associated with such high-z spatially resolved measurements below 10{sup 8} M{sub ⊙} for the first time. Our maps exhibit diverse morphologies, indicative of various effects such as efficient radial mixing from tidal torques, rapid accretion of low-metallicity gas, and other physical processes that can affect the gas and metallicity distributions in individual galaxies. Based upon an exhaustive sample of all existing sub-kiloparesec resolution metallicity gradient measurements at high z, we find that predictions given by analytical chemical evolution models assuming a relatively extended star-formation profile in the early disk-formation phase can explain the majority of observed metallicity gradients, without involving galactic feedback or radial outflows. We observe a tentative correlation between stellar mass and metallicity gradients, consistent with the “downsizing” galaxy formation picture that more massive galaxies are more evolved into a later phase of disk growth, where they experience more coherent mass assembly at all radii and thus show shallower metallicity gradients. In addition to the spatially resolved analysis, we compile a sample of homogeneously cross-calibrated integrated metallicity measurements spanning three orders of magnitude in stellar mass at z ∼ 1.8. We use this sample to study the mass–metallicity relation (MZR) and find that the slope of the observed MZR can rule out the momentum-driven wind model at a 3σ confidence level.

79 ASTRONOMY AND ASTROPHYSICS↗

SDSS-IV MaNGA: pyPipe3D Analysis Release for 10,000 Galaxies

We present here the analysis performed using the pyPipe3D pipeline for the final MaNGA data set included in the Sloan Digital Sky Survey data release 17. This data set comprises more than 10,000 individual data cubes, being the integral field spectroscopic (IFS) galaxy survey with the largest number of galaxies. pyPipe3D processes the IFS data cubes to extract spatially resolved spectroscopic properties of both the stellar population and the ionized gas emission lines. A brief summary of the properties of the sample and the characteristics of the analyzed data are included. The article provides details of: (i) the analysis performed; (ii) a description of the pipeline; (iii) the adopted stellar population library; (iv) the morphological and photometric analysis; (v) the adopted data model for the spatially resolved properties derived; and (vi) the individual integrated and characteristic galaxy properties included in the final catalog. Comparisons with the results from a previous version of the pipeline for earlier data releases and from other tools using this data set are included. A practical example of how to use the full data set and the final catalog illustrates how to handle the delivered product. Our full analysis can be accessed and downloaded from our web page.

79 ASTRONOMY AND ASTROPHYSICS↗