Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUID MEASUREMENT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Lab-Scale Stimulation Results on Surrogate Fused Silica Samples

Lab-scale stimulation work on non-porous fused silica (similar mechanical properties to igneous rock) was performed using pure water, pure CO2 and water/CO2 mixtures to compare back to back fracturing performance of these fluids with PNNL's StimuFrac.

15 GEOTHERMAL ENERGY↗

Potential for Induced Seismicity Related to the Northern California CO2 Reduction Project Pilot Test, Solano County, California

The objective of this technical report is to analyze the potential for induced seismicity due to a proposed small-scale CO{sub 2} injection project in the Montezuma Hills. We reviewed currently available public information, including 32 years of recorded seismic events, locations of mapped faults, and estimates of the stress state of the region. We also reviewed proprietary geological information acquired by Shell, including seismic reflection imaging in the area, and found that the data and interpretations used by Shell are appropriate and satisfactory for the purpose of this report. The closest known fault to the proposed injection site is the Kirby Hills Fault. It appears to be active, and microearthquakes as large as magnitude 3.7 have been associated with the fault near the site over the past 32 years. Most of these small events occurred 9-17 miles (15-28 km) below the surface, which is deep for this part of California. However, the geographic locations of the many events in the standard seismicity catalog for the area are subject to considerable uncertainty because of the lack of nearby seismic stations; so attributing the recorded earthquakes to motion along any specific fault is also uncertain. Nonetheless, the Kirby Hills Fault is the closest to the proposed injection site and is therefore our primary consideration for evaluating the potential seismic impacts, if any, from injection. Our planned installation of seismic monitoring stations near the site will greatly improve earthquake location accuracy. Shell seismic data also indicate two unnamed faults more than 3 miles east of the project site. These faults do not reach the surface as they are truncated by an unconformity at a depth of about 2,000 feet (610 m). The unconformity is identified as occurring during the Oligocene Epoch, 33.9-23.03 million years ago, which indicates that these faults are not currently active. Farther east are the Rio Vista Fault and Midland Fault at distances of about 6 miles (10 km) and 10 miles (16 km), respectively. These faults have been identified as active during the Quaternary (last 1.6 million years), but without evidence of displacement during the Holocene (the last 11,700 years). The stress state (both magnitude and direction) in the region is an important parameter in assessing earthquake potential. Although the available information regarding the stress state is limited in the area surrounding the injection well, the azimuth of the mean maximum horizontal stress is estimated at 41{sup o} and it is consistent with strike-slip faulting on the Kirby Hills Fault, unnamed fault segments to the south, and the Rio Vista Fault. However, there are large variations (uncertainty) in stress estimates, leading to low confidence in these conclusions regarding which fault segments are optimally oriented for potential slip induced by pressure changes. Uncertainty in the stress state can be substantially reduced by measurements planned when wells are drilled at the site. Injection of CO{sub 2} at about two miles depth will result in a reservoir fluid pressure increase, which is greatest at the well and decreases with distance from the well. After the injection stops, reservoir fluid pressures will decrease rapidly. Pressure changes have been predicted quantitatively by numerical simulation models of the injection. Based on these models, the pressure increase on the Kirby Hills Fault at its closest approach to the well due to the injection of 6,000 metric tons of CO{sub 2} would be a few pounds per square inch (psi), which is a tiny fraction of the natural pressure of approximately 5,000 psi at that depth. The likelihood of such a small pressure increase triggering a slip event is very small. It is even more unlikely that events would be induced at the significantly greater depths where most of the recorded earthquakes are concentrated, because it is unlikely that such a small pressure pulse would propagate downwards any appreciable distance. Therefore, in response to the specific question of the likelihood of the CO{sub 2} injection causing a magnitude 3.0 (or larger) event, this preliminary analysis suggests that no such induced or triggered events would be expected. However, it is possible that a fault, too small to be detected by the existing seismic data, yet sufficiently large to cause a magnitude 3 event, could exist in close proximity to the injection point where the pressure increase could cause slippage. However, the existence of such a fault would be detectable in the data planned for collection from the well prior to injection. We do note that natural earthquake events of up to 3.7 in magnitude have occurred in this area and would be expected to occur again regardless of the proposed CO{sub 2} injection.

54 ENVIRONMENTAL SCIENCES↗

Mapping the performance of a versatile water-based condensation particle counter (vWCPC) with numerical simulation and experimental study

Accurate airborne aerosol instrumentation is required to determine the spatial distribution of ambient aerosol particles, particularly when dealing with the complex vertical profiles and horizontal variations of atmospheric aerosols. A versatile water-based condensation particle counter (vWCPC) has been developed to provide aerosol concentration measurements under various environments with the advantage of reducing the health and safety concerns associated with using butanol or other chemicals as the working fluid. However, the airborne deployment of vWCPCs is relatively limited due to the lack of characterization of vWCPC performance at reduced pressures. Given the complex combinations of operating parameters in vWCPCs, modeling studies have advantages in mapping vWCPC performance. In this work, we thoroughly investigated the performance of a laminar-flow vWCPC using COMSOL Multiphysics® simulation coupled with MATLAB™. We compared it against a modified vWCPC (vWCPC model 3789, TSI, Shoreview, MN, USA). Our simulation determined the performance of particle activation and droplet growth in the vWCPC growth tube, including the supersaturation, $D$ p,kel,0 (smallest size of particle that can be activated), $D$ p,kel,50 (particle size activated with 50 % efficiency) profile, and final growth particle size D d under wide operating temperatures, inlet pressures $P$ (30–101 kPa), and growth tube geometry (diameter $D$ and initiator length $L$ ini ). The effect of inlet pressure and conditioner temperature on vWCPC 3789 performance was also examined and compared with laboratory experiments. The COMSOL simulation result showed that increasing the temperature difference (Δ$T$) between conditioner temperature $T$ con and initiator $T$ ini will reduce $D$ p,kel,0 and the cut-off size $D$ p,kel,50 of the vWCPC. In addition, lowering the temperature midpoint ($T$ mid = $\frac{T_{con}+T_{ini}}{2}$ increases the supersaturation and slightly decreases the $D$ p,kel . The droplet size at the end of the growth tube is not significantly dependent on raising or lowering the temperature midpoint but significantly decreases at reduced inlet pressure, which indirectly alters the vWCPC empirical cut-off size. Our study shows that the current simulated growth tube geometry ($D$=6.3 mm and $L$ ini =30 mm) is an optimized choice for current vWCPC flow and temperature settings. The current simulation can more realistically represent the $D$ p,kel for 7 nm vWCPC and also achieved good agreement with the 2 nm setting. Using the new simulation approach, we provide an optimized operation setting for the 7 nm setting. This study will guide further vWCPC performance optimization for applications requiring precise particle detection and atmospheric aerosol monitoring.

47 OTHER INSTRUMENTATION↗

Modeling the multiphase flow in a dense medium cyclone

A mathematical model is proposed to describe the multiphase flow in a dense-medium cyclone (DMC). In this model, the volume of fluid multiphase model is first used to determine the shape and position of the air core, and then the mixture multiphase model is employed to describe the flow of the dense medium (comprising finely ground magnetite in water) and the air core, where the turbulence is described by the Reynolds stress model. The results of fluid flow are finally used in the simulation of coal particle flow described by the stochastic Lagrangian particle tracking model. The validity of the proposed approach is verified by the reasonably good agreement between the measured and predicted results under different conditions. The flow features in a DMC are then examined in terms of factors such as flow field, pressure drop, particle trajectories, and separation efficiency. The results are used to explain the key characteristics of flow in DMCs, such as the origin of a short-circuit flow, the flow pattern, and the motion of coal particles. Moreover, the so-called surging phenomenon is examined in relation to the instability of fluid flow. The model offers a convenient method to investigate the effects of variables related to geometrical and operational conditions on the performance of DMCs.

01 COAL, LIGNITE, AND PEAT↗

In-Situ Stress Measurements at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) Site

A scientific injection campaign was conducted at the Utah Frontier Observatory for Research in Geothermal Energy (FORGE) site in 2017 and 2019. The testing included pump-in/shut-in, pump-in/flowback, and step rate tests. Various methods have been employed to interpret the in-situ stress from the test dataset. This study focuses on methods to interpret the minimum in-situ stress from step rate, pump-in/extended shut-in tests data obtained during the stimulation of two zones in Well 58-32. This well was drilled in low-permeability granitoid. A temperature of 199 °C was recorded at the well’s total depth of 2297 m relative to the rotary Kelly bushing (RKB). The lower zone (Zone 1) consisted of 46 m of the openhole at the toe of the well. Fractures in the upper zone (Zone 2) were stimulated between 2123–2126 m measured depths (MD) behind the casing. The closure stress gradient variation depended on the depth and the injection chronology. The closure stress was found to increase with the pumping rate/volume. This stress variation could indicate that poroelastic effects (“back stress”) and the presence of adjacent natural fractures may play an important role in the interpretation of fracture closure stress. Further, progressively increasing local total stresses may, consequently, have practical applications when moderate volumes of fluid are injected in a naturally fractured or high-temperature reservoir. The alternative techniques that use pump-in/flowback tests and temperature signatures provide a valuable perspective view of the in-situ stress measurements.

15 GEOTHERMAL ENERGY↗

MARS-F/K modeling of plasma response and fast ion losses due to RMP in KSTAR

Abstract The toroidal single-fluid magnetohydrodynamic (MHD) code MARS-F (Liu et al 2000 Phys. Plasmas 7 3681) and the MHD-kinetic hybrid code MARS-K (Liu et al 2008 Phys. Plasmas 15 112503) are utilized to study the plasma response to the n = 1 ( n is the toroidal mode number) resonant magnetic perturbation (RMP), applied to suppress the type-I edge localized mode (ELM) in a KSTAR discharge. Both the resistive-rotating and ideal-static plasma models identify strong screening of the resonant radial field harmonics of the applied RMP due to the plasma response, and predict a strong edge-peeling response of the plasma which is consistent with the optimal ELM control coil current configuration adopted in experiment. The RMP-induced radial displacement of the plasma, computed by the resistive-rotating plasma model, agrees reasonably well with that reconstructed from the measured data in the plasma core. Taking into account the drift kinetic response of fast ions, MARS-K hybrid modeling also finds quantitative agreement of the plasma core fluid pressure perturbation with experiment. Based on the MARS-F computed plasma response, a guiding-center orbit-tracing simulation finds about 0.3% of fast ion losses due the n = 1 RMP in the KSTAR ELM control experiment considered. Most losses are associated with counter-current fast ions located near the plasma edge.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

UNH TDP - Concurrent Measurements of Inflow, Power Performance, and Loads for a Grid-Synchronized Vertical Axis Cross-Flow Turbine Operating in a Tidal Estuary

This data was collected between October 12 and December 15 of 2021 at the University of New Hampshire (UNH) and Atlantic Marine Energy Center (AMEC) turbine deployment platform (TDP). This data set includes over 29 days of grid connected turbine operation during this 65 day time frame. The priority for this measurement campaign was to collect data while the turbine was electrically connected to the grid by means of a rectifier and inverter. The Fall_2021_UNH_Measurement_Timeline.png highlights when each instrument was functioning and the Fall_2021_UNH_Test_Log.jpg indicates the four main regions for analysis available from this measurement campaign. The TDP is a floating structure moored on the Portsmouth facing side of Memorial Bridge pier #2, which spans the Piscataqua River between Portsmouth, NH and Kittery, ME. The Piscataqua River connects the Great Bay Estuary to the Gulf of Maine and the river currents are dominated by tidal forcing with water velocities exceeding 2.5 m/s during spring ebb tides at this site which were previously characterized by Kaelin Chancey (Assessment Of The Localized Flow And Tidal Energy Conversion System At An Estuarine Bridge - UNH MS Thesis 2019). The turbine under test was a modified New Energy Corporation (Calgary, CA) model EVG-025 4-blade H-Darrius type vertical axis cross flow turbine that rotates in the clockwise direction with a rotor diameter of 3.2m and blade length of 1.7m. The hydro-foil profile was a NACA 0021 with a 10 inch chord length and a blade preset pitch angle of +4deg with a positive angle corresponding with the toe in direction. The standard EVG-025 has a rotor diameter of 3.4m and its rated power output is 25kW at 3 m/s. The rotor diameter was reduced to accommodate the size of the existing TDP moon-pool. This project was pursued to quantify device performance for cross flow turbines operating in a marine environment. Accurate physical models, to characterize cross flow turbine performance, require real operational data sets due to the complexity of blade fluid interactions. This data can help support model development which will help predict turbine performance when analyzing perspective project locations in the future. Instrumentation was deployed to measure; water speed/direction, electrical power output, turbine shaft speed, turbine thrust force, and platform motion. Concurrent measurements of these parameters allow for correlations (cause and affect) to be inferred, allowing for characterization of device performance over a range of operating conditions. Water currents were measured using Acoustic Doppler Current Profilers (ADCP's) and Acoustic Doppler Velocimeters (ADV's) directly upstream and downstream of the turbine for inflow, wake and turbulence measurements. Electrical power output was measured using the Voltsys rectifier and the Shark power meter. Shaft speed was calculated based on the Voltsys measurements of the permanent magnet three phase generator AC generation frequency, coupled directly to the cross flow turbine under test (i.e., no gear box). Platform motions were captured using a Yost IMU (inertial measurement unit). Turbine thrust loading was measured using a reaction arm about the turbine deployment platform spanning beam, where two bi-directional load cells were connected to the system via a pinned connection. This submission includes zipped folders for each instrument containing quality controlled (QC'd) data in daily .csv files for the relevant duration specific to each instrument, along with separate .csv file that contains the units for each variable. Some instrument daily files are quite large and can pose a challenge for a visual spreadsheet editor to open. A processing software like MATLAB or Python is recommended. Note the degree of QC varied between each instrument due to time constraints. Particular time and attention was given to perform quality control tests on the acoustic based instruments that are particularly suscep...

16 TIDAL AND WAVE POWER↗

Experimental Evidence for Self-Limiting Reactive Flow through a Fractured Cement Core: Implications for Time-Dependent Wellbore Leakage

We present a set of reactive transport experiments in cement fractures. The experiments simulate coupling between flow and reaction when acidic, CO{sub 2}-rich fluids flow along a leaky wellbore. An analog dilute acid with a pH between 2.0 and 3.15 was injected at constant rate between 0.3 and 9.4 cm/s into a fractured cement core. Pressure differential across the core and effluent pH were measured to track flow path evolution, which was analyzed with electron microscopy after injection. In many experiments reaction was restricted within relatively narrow, tortuous channels along the fracture surface. The observations are consistent with coupling between flow and dissolution/precipitation. Injected acid reacts along the fracture surface to leach calcium from cement phases. Ahead of the reaction front, high pH pore fluid mixes with calcium-rich water and induces mineral precipitation. Increases in the pressure differential for most experiments indicate that precipitation can be sufficient to restrict flow. Experimental data from this study combined with published field evidence for mineral precipitation along cemented annuli suggests that leakage of CO{sub 2}-rich fluids along a wellbore may seal the leakage pathway if the initial aperture is small and residence time allows mobilization and precipitation of minerals along the fracture.

42 ENGINEERING↗

An alternative electrode design for accurate spectral induced polarization measurements in variably saturated porous media

SUMMARY Applications of spectral induced polarization (SIP) require electrodes that maintain hydrologic contact with surrounding soils to capture small electrical responses, often observed as phase shifts in milliradians. For unsaturated soils, electrodes must overcome increased electrical contact impedance due to reduced pore fluid. Traditional designs use a ceramic membrane electrode (CME) with a water reservoir and metal conductor, requiring periodic maintenance to retain electrolytic solution. For field applications where maintenance is impractical, alternative designs are needed. This study evaluated a new electrode design (silica flour electrode, SFE) alongside a CME. SFEs use packed silica flour to store water via capillary forces against a metal conductor. This study examined both designs in three variably saturated soils at soil suctions up to 700 mbar and soil water contents below 1 percent, with SIP measurements across 0.01 to 10 000 Hz frequencies. SFEs match CMEs at high frequencies and perform better at lower frequencies, without requiring ongoing maintenance, making them ideal for field use. In water-only experiments, CMEs produced errors and high noise below 1.5 Hz, whereas SFEs were more accurate. However, CMEs performed better above 300 Hz. In fine sand, SFEs performed better due to the relatively lower contact impedance as compared to CMEs. Both electrode types performed comparably in silty sand and silt loam soils, although CMEs required ongoing maintenance, suggesting potential for long-term reliability issues.

58 GEOSCIENCES↗

Quantitative Characterization of Impacts of Coupled Geomechanics and Flow on Safe and Permanent Geological Storage of CO 2 in Fractured Aquifers

This is the final scientific report for the award DE-FE0023305, entitled “Quantitative Characterization of Impacts of Coupled Geomechanics and Flow on Safe and Permanent Geological Storage of CO 2 in Fractured Aquifers.” The work has been divided into six tasks. In Task 2, we characterized rock properties, which are important when developing a quantitative approach for understanding and predicting geomechanical effects on large-scale CO 2 injection and long-term storage in the subsurface. Rock properties of interest for this characterization include porosity, permeability, elastic constants, strength, and heat capacity. We measured rock properties for three different rock types: concrete, sandstone and shale. These properties were obtained from the acoustic measurement, permeability and porosity measurement, Brazilian test, the uniaxial compressive test, and heat capacity measurement. Then, using the Brazilian technique to fracture samples, we measured their permeability under brine injection for varying effective stresses, followed by similar measurements of permeability under sc-CO 2 injection. Permeability to brine and sc-CO 2 decreased as the effective stress increased. The apparent permeability to sc-CO 2 was an order of magnitude less than that for brine, a consequence of CO 2 being the non-wetting fluid. In Task 3, we developed understandings and correlations for CO 2 injection pressure induced fracturing. We initially fractured four eight inch cubes of concrete with brine to establish a standard test procedure. Then, additional concrete samples were fractured using brine. Confining stresses were exerted on the samples and brine was injected at a constant rate into a borehole that was previously drilled into the concrete cube. The borehole pressure was measured and fracture initiation was identified as a peak in the pressure profile. That was followed by fracture propagation, which was identified as a plateau in the pressure profile, and finally the fracture reached the sample surface. The sample surfaces were photographed before and after fracturing, which enabled determination of where the fracture reached the sample surface. Afterwards, aqueous food dye solution was injected into the fractured concrete samples to color the fracture planes. The borehole was filled with food dye solution in advance, a gas pulse was transmitted to the borehole, and the borehole was then shut in to allow the food dye to be driven into existing fractures. Then, the concrete samples were broken down by high-pressure gas injection to reveal the geometry and morphology of the hydraulic fractures. In addition, acoustic measurements were conducted on multiple locations on each face of the concrete samples before and after injection for comparison. This comparison was used to confirm changes in the internal structure of the concrete sample, namely the formation of fractures. There were six concrete samples fractured with brine. Afterwards, concrete samples were fracture using sc-CO 2 . The main change in experimental procedure was the inclusion of temperature control, since in the field, we mostly encounter temperature and pressure conditions above the supercritical point of CO 2 . The concrete samples were pre-heated in an oven to elevate their temperature, and thermal tape was used to heat the CO 2 to a temperature above its supercritical temperature. Two concrete samples were fractured using liquid CO 2 , four concrete samples were fractured using gaseous CO 2 , and twenty two concrete samples were fractured using sc-CO 2 . For the concrete samples fractured using sc-CO 2 , three had pre-existing hydraulic fractures on the surface near the wellbore, and two were water saturated (as opposed to containing only air). Two concrete samples were composite samples, with a high permeability ball in the center, in order to represent CO 2 injection into a high permeability zone surrounded by a low permeability sealing formation. Later, we fractured five shale samples, obtained from the Niobrara shale outcrop, with sc-CO 2 . The injection rate was constant, confining stresses were applied, the shale samples were pre-heated in an oven to the desired temperature, and the sample was then fractured. An analysis of the failure type was done for many of the concrete samples, based on the predicted break down pressure for tensile and shear failure, and it was found that most samples fractured due to shear failure. Also, the presence of induced fractures has little to no effect on the fracture initiation pressure, but significantly changes the fracture morphology. The CO 2 fracturing in water saturated samples behaved much similar to brine induced fracturing. There was a significant difference of breakdown pressure for injection of CO 2 and brine, where the breakdown pressure for CO 2 induced fracturing is generally around the minimum horizontal stress and that for brine is much higher. Finally, the fracture orientation for most samples with large confining stress differential was perpendicular to the minimum horizontal stress. When the stress differential, especially the difference between the two directions with the smallest stresses was small, the fracture orientation was determined not only by the minimum stress direction, but also the magnitude of the confining stress, the tensile strength of the rock, and the breakdown pressure. In Task 4, we modified our coupled flow-geomechanical models to model fracture growth and propagation in storage formations and caprocks. These flow-geomechanical models are TOUGH2-CSM and TOUGH2-FLAC. The TOUGH2-CSM fluid and heat flow formulation is based on the TOUGH2 formulation of mass and energy conservation equations that govern fluid and heat flow in general multiphase, multicomponent, multi-porosity systems. The TOUGH2-CSM simplified geomechanical formulation is based on the linear theory of elasticity applied to multi-porosity non-isothermal (thermo-multi-poroelastic) media. We previously derived, from the fundamental relations of the linear theory of elasticity, an equation relating mean stress, pore pressures, temperatures, and body force (the Mean Stress equation) that we added to the TOUGH2-CSM fluid and heat flow equations. We extended the TOUGH2-CSM simplified geomechanical formulation to calculate the entire stress tensor by deriving equations for stress tensor components from derivatives of the Cartesian thermo-multi-poroelastic Navier equation components. In addition, we derived equations for stress tensor components in rz-coordinates. We solved these geomechanical equations using the integral finite difference method. This method utilizes momentum fluxes obtained by “factoring” a divergence operator out of each geomechanical equation. In Task 5, we did a literature survey to determine suitable correlations for fracture initiation, growth, and propagation. After surveying numerous papers, we modified TOUGH2-CSM to model stress dependent fracture initiation and growth using the Mohr-Coulomb criterion for shear failure in faults and caprock and the condition of negative minimum effective stress for tensile failure. Tensile failure results in a fracture whose width depends on the difference between fracture pressure and minimum stress and whose propagation is based on the difference between the stress intensity factor at the fracture tip and the rock toughness. The TOUGH-FLAC model is based on the FLAC3D ubiquitous joint model, extended for the modeling of permeability changes induced by changes in effective normal stress across fractures as well permeability changes caused by shearing along fractures. In Task 6, we validated our coupled flow-geomechanical models using analytical solutions and problems from the literature. We validated the TOUGH2-CSM modifications using analytical solutions to the displacement from a uniform load on a semi-infinite elastic medium and the two-dimensional Mandel-Cryer effect. Those were followed by a sample problem to test our stress tensor calculations, which was for injection into a single-phase reservoir with constant properties. Comparisons of our simulator to published results were done on for the depletion of a single-phase reservoir with stress dependent porosity, two examples from the In Salah gas project, an axisymmetric baserock–reservoir–caprock system with a normal faulting stress regime that had thermally induced shear stresses, simulations of CO 2 leakage through caprock in a two-dimensional reservoir in Cartesian coordinates, and predictions of caprock failure from CO 2 injection into an axisymmetric reservoir. Finally, we simulated CO 2 injection pressure-induced fracturing from one of our laboratory studies, Sample 39, and obtained a fracture profile. We also validated the TOUGH2-FLAC model for fluid driven fracture growth against solutions based on the KGD model and a case with an inclined fracture that was loaded from the boundaries to achieve wing-crack propagation. The strain softening tensile behavior and softening of modulus considering a simple damage approach was verified by a simulation representing hydraulic fracturing stress measurement around a vertical well. Finally, the model was validated against deep fracture zone opening and surface uplift at In Salah with inverses analysis used to improve the match of simulation with field data. In Task 7, we developed a scheme based on inverse modeling that can be used to identify caprock leakage. Injection of fluid into a reservoir results in a time varying pressure profile that depends on the properties of the rock and the fluid. The presence of significant caprock leakage would effect this pressure profile and we used inverse modeling, namely the Levenberg-Marquardt method, to determine the leakage location from the pressure profile. A two-dimensional and a three-dimensional example based on published data were presented. The published simulation was run and its results were considered as “field” data. In the two-dimensional example, a simulation of CO 2 injection into a two-dimensional aquifer-caprock system, the caprock had a vertical fault through which leakage could occur. The location of this leakage was obtained from our inverse modeling scheme. In the three-dimensional example, the simulation domain had four geological layers, one of which was the injection zone that contained a horizontal injection well. We simulated fractures as high permeability gridblocks, introduced a fracture that spanned the caprock depth, and ran a simulation to obtain “field” data. Then, using our inverse modeling scheme, we obtained the location of that fracture.

58 GEOSCIENCES↗

Finite element analysis of ring-shaped emission profile in plasma bullet

Using a one-way coupled model of neutral gas flow and plasma dynamics we report a mechanism to explain the ring-shaped emission pattern that has been observed experimentally in plasma bullets at atmospheric pressure. We solve a fluid model with the local field approximation in one-dimensional cylindrical coordinates, corresponding to a cross-section of a plasma bullet. Pulselike uniform electric field is assumed to be applied perpendicular to the simulation domain. Time and spatially resolved spectroscopic measurements support the simulation results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Study of CO2 laser smoothing of surface roughness in fused silica

Small micrometer-sized roughness on optical surfaces, caused by laser damage and/or redeposition of laser ablated material, can cause local electric field intensification which may lead to damage initiation both on the optics and/or downstream. We examined the smoothing of etched periodic surface structures on SiO{sub 2} substrate with 10.6 {micro}m CO{sub 2} laser using atomic force microscopy. The characteristic surface tension driven mass flow of the glass under different laser parameters were simulated using computational fluid dynamics and correlated with experimental results. We found that during CO{sub 2} laser polishing the estimate viscosity of the silica glass appears to be higher than typical literature values measured at a temperature similar to the laser heating conditions. This discrepancy can be explained by the observation that at high temperature, a significant portion of the hydroxyl content in the layer of heated silica glass can diffuse out resulting in a much stiffer glass.

42 ENGINEERING↗

Computational Fluid Dynamics Simulations of Glass Vitrification Refractory Coupon Tests

The Waste Treatment and Immobilization Plant (WTP) at the Hanford site is nearing the start of the Direct-Feed Low-Activity Waste (DFLAW) operations. DFLAW is destined to convert a pretreated low activity waste portion of the 56 million gallons of tank waste into a stable solid glass. In the subsequent decade completion of the high-level waste (HLW) facility is anticipated. Sustained operational missions of both LAW and HLW melter facilities are expected over multiple decades. In high-temperature glass melters, the refractory lining corrodes over time, which could potentially be an issue for longer term operations, this refractory corrosion is higher at the level of the glass-air interface due to surface tension driven flow. The glass viscosity, melt pool temperature, and glass chemical composition can impact the rate at which the refractory corrodes. This rate is important to quantify for the various waste glasses to be produced at the WTP since the integrity of the refractory should not be a limiting factor affecting the lifetime of the melter. To this end, a series of glasses representative of the first batches of waste glass produced by the WTP will be melted in small-scale crucibles with Monofrax® K-3 coupons inserted. The corrosion of the K-3 will be measured in the melt and at the meltline (or neckline). A model for the corrosion rate will be constructed and implemented into a previously developed framework for a computational fluid dynamics (CFD) model of the full-scale WTP. To assist with experimental design and validate the implementation of the model in the full-scale melter, CFD simulations of the small-scale crucible tests were performed. The bubbling that occurs in the small-scale crucible is initially validated here with a model that uses silicone oil at room temperature. The viscosity of the oil ranges from 1 to 100 Pa•s, which corresponds to operating glass pool temperatures near 1150 °C down to idling temperatures near 950 °C. The simulation results show good agreement with the bubble sizes that form during experiments. CFD modeling of the crucible setup was used to determine bubbling characteristics to match the range of near-wall velocities expected in the full-scale WTP. This study presents the initial CFD modeling results, corrosion testing plan, and some preliminary corrosion samples with an outline for the next steps for the development of the corrosion model.

Abboud, Alexander W. [Idaho National Lab]↗

Bonneville Powerhouse 2 Fish Guidance Efficiency Studies: CFD Model of the Forebay

In ongoing work, U.S. Army Corps of Engineers, Portland District (CENWP) is seeking to better understand and improve the conditions within the Bonneville Powerhouse 2 (B2) turbine intakes to improve survival of downstream migrant salmonid smolt. In this study, the existing B2 forebay computational fluid dynamics (CFD) model was modified to include a more detailed representation of all B2 turbine intakes. The modified model was validated to existing field-measured forebay ADCP velocities. The initial CFD model scenarios tested a single project operation and the impact of adding the Behavior Guidance System (BGS) or Corner Collector. These structures had impacts on forebay flows. Most notable was that the addition of the BGS and Corner Collector reduced the lateral extent of the recirculation areas on the Washington shore and Cascade Island and reduced the flow velocity parallel to the powerhouse in front of Units 11 and 12. For these same cases, at the turbine intakes across the powerhouse, there was very little difference in the flow volume into the gatewell for the clean forebay, and the forebay with the BGS in place and/or the Corner Collector operating. The largest differences were at Units 11 to 13. The CFD model cases testing the impact of the gatewell slot fillers showed no impact to the forebay flows, but large differences within the gatewells. With the slot fillers, the flow above the standard traveling screen and into the gatewell increased (about 100 cfs at each turbine intake) and the gap flow decreased across the powerhouse for all cases. The increased flow up the gatewell was further enhanced with only half the units operating. The flow into the gatewell slot was increased about 35 cfs for each bay of each intake across the powerhouse; this change was uniform across the powerhouse. The flows in the gatewell of Unit 12, the most impacted unit for the scenarios, was evaluated. In front of the vertical barrier screen, the CFD model with slot fillers showed reduced the maximum velocities (in spite of the increased the flow into the gatewell), and decreased the area of recirculation. The area near the VBS exceeding the normal velocity criteria of 1 ft/s was reduced and the flows were more balanced.

Bonneville↗

Observation and numerical analysis of plasma parameters in a capillary discharge-produced plasma channel waveguide

We observed the parameters of the discharge-produced plasma in cylindrical capillary. Plasma parameters of the waveguide were investigated by use of both a Normarski laser interferometer and a hydrogen plasma line spectrum. A space-averaged maximum temperature of 3.3 eV with electron densities of the order of 10{sup 17} cm{sup -3} was observed at a discharge time of 150 ns and a maximum discharge current of 200 A. One-dimensional dissipative magnetohydrodynamic (MHD) code was used to analyze the discharge dynamics in the gas-filled capillary discharge waveguide for high-intensity laser pulses. Simulations were performed for the conditions of the experiment. We compared the temporal behavior of the electron temperature and the radial electron density profiles, measured in the experiment with the results of the numerical simulations. They occurred to be in a good agreement. An ultrashort, intense laser pulse was guided by use of this plasma channel.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

First- and second-sound-like modes at finite temperature in trapped Fermi gases from BCS to BEC

We determine the temperature (T) dependence of first- and second-sound-like mode frequencies for trapped Fermi gases undergoing the BCS to Bose-Einstein condensation (BEC) crossover. Our results are based on numerical solution of the two-fluid equations in conjunction with a microscopic calculation of thermodynamical variables. As in experiment and at unitarity, we show that the lowest radial breathing mode is T independent. At finite T, higher-order breathing modes strongly mix with second sound. Their complex T dependence should provide an alternative way of measuring the transition temperature T{sub c}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Cosmological backreaction for a test field observer in a chaotic inflationary model

In an inhomogeneous universe, an observer associated with a particular matter field does not necessarily measure the same cosmological evolution as an observer in a homogeneous and isotropic universe. Here we consider, in the context of a chaotic inflationary background model, a class of observers associated with a ''clock field'' for which we use a light test field. We compute the effective expansion rate and fluid equation of state in a gauge invariant way, taking into account the quantum fluctuations of the long wavelength modes, and working up to second order in perturbation theory and in the slow-roll approximation. We find that the effective expansion rate is smaller than what would be measured in the absence of fluctuations. Within the stochastic approach we study the bounds for which the approximations we make are consistent.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental measurement of the effective contact angle for solvent/packing interactions in a structured packed column for CO 2 capture

The contact angle is a critical factor for determining the effective mass transfer area for carbon dioxide (CO 2 ) capture via the chemical absorption process in a packed column, and thus the overall capture efficiency of the packed column. Many widely used commercial packings involve microscale features (perforation, corrugation, etc.) that may also affect the wetting behavior. This study proposes a systematic method of using a modified Wilhelmy plate to measure the effective contact angle to characterize the solvent and featured packing interaction. In lieu of computational efforts relying on assumptions guided by semi-informed correlation, the proposed method directly measures the effective contact angle as a function of the solvent and packing thermophysical and hydrodynamic properties. The characterization of the effective contact angle is then integrated in the computational fluid dynamics modeling to reduce uncertainty in the prediction of effective mas transfer area. Experiments were conducted for stainless steel coupons using water and aqueous sodium hydroxide (NaOH) solvent for verification of the proposed experimental protocol. The surface tension of the aqueous NaOH solvent was altered using surfactant and antifoam. The effective contact angle increases with the increased value of the surface tension for flat stainless steel sheets. On the other hand, effective contact angles do not vary in Mellapak coupons for aqueous monoethanolamine (MEA) and NaOH solvent. In this case, surface textures and sheet design play a dominant role in the surface tension of solvents. Furthermore, CO 2 loading has a significant effect on the contact angle for Mellapak coupons. As expected, the contact angle decreases with the increasing temperature of CO 2 capture solvents (MEA, EEMPA). The effective contact angle measurement using the Wilhelmy plate method can provide more accurate and efficient solvents for characterizing the solvent-packing surface interactions. Subsequently, the present method enhances the accuracy of the prediction of the effective mass transfer area in carbon capture by solvent absorption.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗