Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FEEDING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

In-situ active impedance characterization of scanned array antennas

Various embodiments presented herein relate to determining mutual coupling between a pair of antennas in an array antenna. Various operations presented herein enable comparison between a magnitude and phase of a signal transmitted from a first feed network (via a first antenna) and a magnitude and phase of a portion of the signal received at a second feed network (via a second antenna). Electrical effects engendered by any of the first feed network, a first switch, a first local circuit, the second feed network, a second switch, and a second local circuit can also be determined and their effects mathematically removed. Based upon the foregoing, a mutual coupling between the pair of antenna is determined.

42 ENGINEERING↗

Methods and systems for the electrochemical reduction of carbon dioxide using switchable polarity materials

A method of electrochemically reducing CO2 comprises introducing a first feed stream comprising H2O to a positive electrode of an electrolysis cell comprising the positive electrode, a negative electrode, and a proton conducting membrane. A second feed stream comprising a solvent and a non polar form of a switchable polarity material is directed into a CO2 capture apparatus. A third feed stream comprising CO2 is directed into the CO2 capture apparatus to interact with the second feed stream and form a first product stream comprising the solvent and a polar form of the switchable polarity material. The first product stream is introduced to the negative electrode. A potential difference is applied between the positive electrode and the negative electrode to convert the polar form of the switchable polarity material into CO2 and the non-polar form and to form products from the CO2 and the solvent. A CO2 treatment system is also described.

Lister, Tedd E.↗

Methods and apparatus for additively manufacturing structures using in situ formed additive manufacturing materials

A method of additively manufacturing a structure comprises nuclear reactor comprises disposing a feed material on a surface of a substrate in a reaction vessel, disposing at least one material formulated and configured to react with the feed material in the reaction vessel, and exposing the feed material and the at least one material to energy from an energy source to react the feed material and the at least one material to form an additive manufacturing material and reaction by-products. The additive manufacturing material is separated from the reaction by-products and exposed to energy from the energy source to form inter-granular bonds between particles of the additive manufacturing material and form a layer of a structure comprising the additive manufacturing material. Related apparatuses and methods are disclosed.

van Rooyen, Isabella J.↗

Rapid fill compressed gas storage tank

A method for rapidly filling a compressed gas storage tank with a moderated temperature rise using a Coanda nozzle to inject the feed gas into the tank and using the Coanda nozzle to direct the feed gas along the inner surface of the storage tank; entraining the stored gas with the feed gas that is flowing under the influence of the Coanda effect to flow along the inner surface of the gas storage tank; and transferring heat from the flowing gas to the external walls of the tank. Also, a compressed gas storage tank for rapid filling with a moderated temperature rise comprising: a gas storage tank and a Coanda nozzle capable of directing feed gas that is injected into the gas storage tank along the inner surface of the gas storage tank.

Jayaraman, Ambalavanan↗

Methods for the separation of CO2 from a gas stream

Disclosed herein are 2-stage membrane separation methods for capturing CO2 from a feed gas. The methods can employ two selectively permeable membranes, which may be the same or different. The selectively permeable membrane can have a carbon dioxide permeance of from 500 to 3000 GPU at 57° C. and 1 atm feed pressure and a carbon dioxide:nitrogen selectivity of from 10 to 1000 at 57° C. and 1 atm feed pressure. High pressure ratios across the membranes can be achieved by compressing the feed gas to a high pressure, by using vacuum pumps to create a lowered pressure on the permeate side of the membrane, by using a sweep stream, or a combination thereof. When a sweep stream is used, the sweep stream may include a portion of the retentate gas stream obtained from the retentate side of one or more of the membranes used.

Ho, W. S. Winston↗

GeoMelt{sup R} ICV{sup TM} Treatment of Sellafield Pond Solids Waste - 13414

Kurion, Inc., in partnership with AMEC Ltd., is demonstrating its GeoMelt{sup R} In-Container Vitrification (ICV){sup TM} Technology to Sellafield Ltd. (SL). SL is evaluating the proposition of directly converting a container (skip/box/drum) of raw solid ILW into an immobilized waste form using thermal treatment, such that the resulting product is suitable for interim storage at Sellafield and subsequent disposal at a future Geological Disposal Facility. Potential SL feed streams include sludges, ion-exchange media, sand, plutonium contaminated material, concrete, uranium, fuel cladding, soils, metals, and decommissioning wastes. The solid wastes have significant proportions of metallic constituents in the form of containers, plant equipment, structural material and swarf arising from the nuclear operations at Sellafield. GeoMelt's proprietary ICV process was selected for demonstration, with the focus being high and reactive metal wastes arising from solid ILW material. A composite surrogate recipe was used to demonstrate the technology towards treating waste forms of diverse types and shapes, as well as those considered difficult to process; all the while requiring few (if any) pre-treatment activities. Key strategic objectives, along with their success criterion, were established by SL for this testing, namely: 1. Passivate and stabilize the raw waste simulant, as demonstrated by the entire quantity of material being vitrified, 2. Immobilize the radiological and chemo-toxic species, as demonstrated via indicative mass balance using elemental analyses from an array of samples, 3. Production of an inert and durable product as evidenced by transformation of reactive metals to their inert oxide forms and satisfactory leachability results using PCT testing. Two tests were performed using the GeoMelt Demonstration Unit located at AMEC's Birchwood Park Facilities in the UK. Post-melt examination of the first test indicated some of the waste simulant had not fully processed, due to insufficient processing time and melt temperature. A second test, incorporating operational experience from the first test, was performed and resulted in all of the 138 kg of feed material being treated. The waste simulant portion, at 41 kg, constituted 30 wt% of the total feed mass, with over 90% of this being made up of various reactive and non-reactive metals. The 95 liters of staged material was volume reduced to 41 liters, providing a 57% overall feed to product volume reduction in a fully passivated two-phase glass/metal product. The GeoMelt equipment operated as designed, vitrifying the entire batch of waste simulant. Post-melt analytical testing verified that 91-99+% of the radiological tracer metals were uniformly distributed within the glass/cast refractory/metal product, and the remaining fraction was captured in the offgas filtration systems. PCT testing of the glass and inner refractory liner showed leachability results that outperform the DOE regulatory limit of 2 g/m{sup 2} for the radiological species of interest (Sr, Ru, Cs, Eu, Re), and by more than an order of magnitude better for standard reference analytes (B, Na, Si). (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of U and Pu Co-Recovery Process (Co-Processing) for Future Reprocessing

Co-processing process, which is the modified Purex process focused on co-recovery of Pu and U, has been studied at Operation Testing Laboratory, Tokai Reprocessing Plant in JAEA. The set up of the process was performed with flow-sheets study by process calculation to avoid Pu isolation in the whole process and to co-recover Pu/U product solution with a suitable Pu/U ratio (0.5< Pu/U <2). The initial Pu/U ratios of the feed solutions were taken as 1%, 3% and 20% considering the composition of the future spent fuels. The verification of the flow-sheets for each feed solutions were carried out with mixer-setters and active Pu/U feed solutions, focusing on the partitioning unit, and favorable back extraction performances of Pu accompanied by U were observed at all cases of the given feed solutions. According to these results, the co-processing process showed a good prospect to treat all kinds of future fuels from LWR, LWR-MOX and FBR, and a good prospect to be simplified by omitting the Pu/U purification cycle.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Controllability of plutonium concentration for FBR fuel at a solvent extraction process in the PUREX process

Typical Purex solvent extraction systems for the reprocessing of spent nuclear fuel have a feed material containing dilute, 1% in weight, plutonium, along with uranium and fission products. Current reprocessing proposals call for no separation of the pure plutonium. The work described in this paper studied, by computer simulation, the fundamental feasibility of preparing a 20% concentrated plutonium product solution from the 1% feed by adjusting only the feed rates and acid concentrations of the incoming streams and without the addition of redox reagents for the plutonium. A set of process design flowsheets has been developed to realize a concentrated plutonium solution of a 20% stream from the dilute plutonium feed without using redox reagents. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Estimating the Rate of Solids Accumulation in Double Shell Tanks - 17093

This project describes a method of estimating the rate of solids accumulation in Low Activity Waste Pretreatment System (LAWPS) Double Shell Tanks (DSTs) from solids entrainment and precipitation in order to identify and recommend appropriate control measures to protect LAWPS feed schedules. By comparing various volume fraction solids in transfer volumes with the available tank storage needed to maintain LAWPS feed schedules the number of possible transfers before solids removal is necessary can be determined. A family of curves spanning the range of values of volume fraction solids most frequently observed in grab samples was charted to show the transfer batch number at which point accumulated solids inhibit sufficient storage for waste feed schedules and thereby warrant solids removal. Results of this study indicate that in order to preclude solids removal activities during the LAWPS waste transfers, volume fraction settled solids levels in LAWPS transfers are required to stay below 0.0133 and 0.0183 for Feed Staging Tank 1 and 2, respectively. Results of this study show that the rate of solids accumulation will exceed the requirement, and therefore solids removal capability for LAWPS DSTs upgrades is required. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Near-Complete Retention of Technetium During Vitrification of Hanford Low Activity Waste With Recycle - 17315

Technetium is one of the more volatile radionuclides for which retention in low activity waste (LAW) glass under the high temperature conditions during vitrification can vary depending on feed composition, feed chemistry, and melter operating parameters. High retention of technetium in the glass is desirable in order to minimize the fraction of technetium that is directed to secondary waste streams, which include liquid off-gas treatment system effluents. Consequently, test data are crucial to assess and underpin the assumptions underlying such mass balance projections, the compositions of secondary waste streams, and, in particular, the effects of recycle on increasing the incorporation of technetium in the glass products and minimizing the fraction in non-glass waste forms. Previous testing performed on a scaled melter system that incorporates prototypical off-gas treatment components and real-time recycle of the liquid effluents back to the melter feed demonstrated that recycle resulted in significant increases of the incorporation of technetium into the LAW glass product and behavior that was in good agreement with process models for the system. However, the maximum technetium retention achieved in those tests was less than predicted. Tests conducted in the present work demonstrated, for the first time, near-complete retention of technetium in the LAW glass product with recycle. Holdup of technetium in the vacuum evaporator, which concentrates the liquid effluents prior to their recycle to the melter feed, was identified as the primary reason for the previously observed shortfall. The fate of other volatile constituents was also assessed. In particular, in addition to technetium, rhenium, which is frequently used as a non-radioactive surrogate for technetium, was included in these tests. This allows for a direct comparison of the behavior of rhenium and technetium during vitrification and in the down-stream processes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Cold-cap temperature profile comparison between the laboratory and mathematical model - 15591

The rate of waste vitrification in an electric melter is connected to the feed-to-glass conversion process, which occurs in the cold cap, a layer of reacting feed on top of molten glass. The cold cap consists of two layers: a low-temperature (∼100 deg. C - ∼800 deg. C) region of unconnected, reacting feed and a high-temperature (∼800 deg. C - ∼1100 deg. C) region of molten glass with gas bubbles and cavities. A recently developed mathematical model describes the effect of the cold cap on glass production. For verification of the mathematical model, a cold cap produced in a laboratory-scale melter was subsequently analyzed by correlating structural features of a polished region with those obtained in heat-treated feed samples to determine the temperature profile as a function of cold-cap position. After corrections were made for the diminished volume of bubbles and collapsed cavities that occurred in the cold-cap sample during cooling, the temperature gradients were alike in the model and the laboratory cold cap through the range from ∼500 deg. C to ∼1100 deg. C. The temperature profiles were different in the upper region of the cold cap because the radiant heat from the molten glass in the laboratory-scale melter resulted in dry and hot (∼400 deg. C) surface conditions whereas the model assumed a surface covered by boiling slurry. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development of F and B Operation Strategy with LPSI and H-SIT

In the current nuclear power plants (NPPs), most of the critical safety functions are provided by many active safety systems. However, in order to meet the futuristic goals of safety, relying on these active safety systems alone does not seem to be viable. As passive system has a strength on the mitigation of station black out accident and it also contributes to increase the diversity of mitigation way, application of passive system becomes a paramount in the nuclear industry to enhance the nuclear plant safety. Recently, many researches for developing passive systems and operation strategies have been carried out in the nuclear field. General passive systems and strategies, however, have a critical limitation, especially for passive injection systems. As these systems use gravity as their driving force, it is difficult to inject coolant in a passive way in a high-pressure condition thus depressurization has to be preferentially performed to do passive injection. The problem is that depressurization inevitably causes the loss of core inventory thus it is not preferred in order to secure plant safety. Hybrid safety injection tank (H-SIT) system was newly suggested a few years ago to passively inject the coolant into the reactor coolant system (RCS) without depressurization in a high-pressure condition. The H-SIT system is planned to be integrated into advanced power reactor plus (APR+). Generally, the H-SIT system can inject water using the pressure from nitrogen gas as a conventional safety-injection tank in low-pressure accidents, such as large and medium-break loss of coolant accidents (LOCA). Additionally, the H-SIT system can also inject water using gravitational force in high-pressure accidents. If a high pressure accident occurs, the pressure of each H-SIT is equalized with pressure of pressurizer through equalizing pipes, thus allowing the H-SITs to inject water by gravitational force. In the target plant, four H-SITs are planned to be installed. Each has a 2.5 in diameter equalizing pipe and it can be operated manually. Long-term cooling of core is an ultimate goal of all mitigation actions for plant safety and feed and bleed (F and B) operation strategy is one of the long-term cooling strategies in conventional pressurized water reactor (PWR). The important point of F and B operation is that injection for feed operation is performed by only high pressure safety injection (HPSI) pump because operation of low pressure safety injection (LPSI) pump needs the depressurization and it causes core dry out. As H-SIT is passively operated in an accident situation, it was originally designed for mitigation of station black out accident. Besides, operator can use the H-SIT system same as high pressure injection pump in any accident situations. Thus, function of high pressure injection by H-SIT can be used for feed operation when HPSI pumps fail. If it is possible, H-SIT can make up the core during depressurization then LPSI pumps can be used for F and B operation. In this study, F and B operation strategy with LPSI and HSIT is developed. This is a new concept for the long-term cooling operation. If this strategy is applied, low pressure injection pump can be successfully used for F and B operation thus operator has the additional mitigation way. As this strategy make plant safe even though HPSI and PAFS are both failed, it can effectively enhance the plant safety. For this strategy two RCGVSs and two POSRVs are needed as a depressurization system for bleed operation and only one LPSI is enough for feed operation. H-SIT operation is also needed to make up core inventory during bleed operation. For this operation, four H-SITs have to be used to make up core safely. Based on the risk analysis using PSA method, if this strategy is applied, core damage frequency is 1.868 e-6 which declined 7 percent from original model. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Utilizing Commercial Submersible Mixer Pumps for Sludge Removal in Savannah River Site's Tank 26 - 20289

The Savannah River Site (SRS) Liquid Waste System (LWS) safely manages, stores, treats, and dispositions liquid radioactive waste. The LWS consists of 51 underground waste storage tanks (eight of which are operationally closed and filled with grout), waste evaporators, treatment facilities, and solidification facilities, known as the Defense Waste Processing Facility (DWPF) and Saltstone Production Facility (SPF). One of the waste storage tanks, Tank 26, was placed into service in 1980 as an F Tank Farm (FTF) Evaporator Feed Tank. From 1980 to 2013, Tank 26 received F Canyon receipts and dilute supernate that was then transferred to the 242-16F FTF Evaporator for volume reduction. In 2013, the steam tube bundle failed in the FTF Evaporator, and the decision was made not to repair/resume evaporator operation. During operation of Tank 26, solids built up to a level of 2.03 m in the tank with a volume of 1062.9 kL. Due to the evaporator failure and subsequent shutdown, the solids in Tank 26 were selected to feed Sludge Batch 10, which is collected and prepped prior to being sent to DWPF for final disposition. To accomplish solids removal, Commercial Submersible Mixer Pumps (CSMPs) were selected to slurry the solids in preparation to be sent to Tank 51. Four CSMPs were installed in Tank 26 with each one installed in a separate quadrant of Tank 26. This work would mark the first deployment of CSMPs in an SRS waste tank. The CSMPs were developed in response to operational issues from previous mixing pumps and budgetary constraints. The CSMPs use the concept of modifying commercially available equipment for nuclear waste applications. The CSMPs consist of a 230-horsepower submersible mixing pump (manufactured by GPM, Inc.) joined to a mast fabricated at SRS. For this application, Savannah River Remediation (SRR) design services was challenged to provide a mast design that required no steel superstructure support system on top of Tank 26. Also, SRR design services provided a simplified Tank 26 riser interface that did not require extensive machine parts to adjust height of the suction screen of the CSMP within the tank. Other design improvements include no requirements for tank top radiation monitors and no requirements for flushing of the CSMPs during startup/shutdown operations. The CSMPs were operated at an initial height of 2.29 m above the Tank 26 bottom for 10 days. After sludge sounding, the CSMPs were lowered to a height of 1.52 m with no issues due to proper work planning and the simplified riser interface. With the CSMPs lowered to a level of 1.52 meters above the tank bottom, the CSMPs were operated for 12 days and another sounding was performed. The sounding level came back matching the disturbance depth results of the first pump run. Chemistry samples were analyzed while the tank was left to settle. The analysis revealed enough weight percent solids to provide good feed to Sludge Batch 10. Also, the results revealed the supernate within the mixture would provide good salt solution feed to Salt Waste Processing Facility (SWPF) Salt Batch 3. So, the plan was modified to let the disturbed solids settle and decant the salt solution for addition to SWPF Salt Batch 3. Then water will be added back to Tank 26, and the CSMPs run in order to wash the solids to decrease settling time prior to being sent to Tank 51 for Sludge Batch 10. Utilizing CSMPs for waste removal in an SRS Tank has provided a cost-effective means for further waste removal efforts. In addition, the CSMPs are easier to operate by utilizing a robust and simplified design. The CSMPs performed quite well with no process shutdown or delays during operation. As a result, CSMPs are integral to the future of removing radioactive waste from storage tanks at SRS. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improvements to neutron detection of Pu in solvent for an aqueous buffer tank, magnox reprocessing plant, Sellafield - 14216

The PP Active Feed Tank (PPAFT) is a buffer tank that is not safe by geometry and which is located between the Medium Active (MA) and Plutonium Purification (PP) cycles of the chemical separation process in the Magnox Reprocessing Plant. The PPAFT receives Pu nitrate in acid which has been conditioned ready for the extraction of Pu with TBP/OK (tri-butyl phosphate in kerosene) solvent in the PP Cycle. The criticality safety case for the PPAFT recognises that during both normal operations and potential maloperations solvent which is dissolved (TBP which is present in solution but can be released upon a change in acidity) and entrained (TBP/OK physically carried over but not in solution) will accumulate in the PPAFT. The only practicable route out for Pu in solvent in the PPAFT is the normal process route out from the base of the PPAFT to the PP cycle through intermediate vacuum lift and feed vessels. However, the dished end base of the PPAFT and the intermediate vacuum lift and feed vessels are of particularly challenging geometry. There are five neutron monitors placed around the PPAFT for the detection of Pu in solvent. The original design intent of the neutron detection system was that any single monitor should be able to reveal an accumulation of Pu in solvent before it would potentially be unsafe if fed downstream. However, over time there have been changes to the fuel feed and chemical process of the plant which have had the potential to affect the performance of the neutron monitoring system. The ability of the neutron monitoring system to function to its original intent was questioned. Work has recently been carried out to investigate the capabilities of the PPAFT neutron monitoring system for current plant conditions and to identify potential improvements while making best use of the existing neutron monitors. It was found that moving a neutron monitor from the side to the top of the PPAFT and adding alarms based on the ratio of signals from multiple neutron detectors would be effective in improving detection of Pu in solvent. This paper describes the challenges involved in detecting thin layers of Pu in solvent using neutron monitors, discusses the improvements made to the PPAFT neutron monitors and details the combination of real plant data and modelling with the shielding code MCBEND used to provide confidence in the enhanced neutron monitoring system. (author)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Project Development of an Electrochemical Denitration and Caustic Generation System for HLW Pretreatment at Hanford - 26350

An engineering-scale electrochemical processing skid is proposed to perform the denitration of Hanford tank waste, which would help to mitigate a key process concern with the direct feed processing of the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The reduction of nitrates and organic compounds in the waste feed will directly reduce hazardous NOx and ammonia gases generated during the vitrification process, which in turn will aid in addressing potential regulatory and safety challenges associated with processing large volumes of tank waste. This paper highlights the past legacy work, project layout, accomplishments from Phase 1 and research and development envisioned for Phase 2. An innovative electrochemical denitration and caustic generation (EDCGe) process was demonstrated for the pretreatment of tank waste at the Savannah River Site (SRS) in the early 2000s. The denitration electrolyzer, off-gas abatement system, and caustic generator electrolyzer are being developed with the intent that the denitration electrolyzer will convert nitrate and nitrite anions to nitrogen gas while also yielding other gaseous byproducts, which may include N2O, NH3, VOCs, and H2. The gaseous byproducts will be managed via a tandem off-gas catalyst-bed treatment system. The caustic generation electrolyzer will recycle NaOH from the feed to produce a clean caustic stream for use within the batching tanks at Hanford, aiding in the preparation of waste for WTP. The reduction in hazardous emissions and improved waste treatment processes provides a robust solution for nuclear waste management, contributing to environmental safety and regulatory compliance. The EDCGe technology is being adapted, modified, and updated for the preparation of the Direct Feed-High Level Waste (DF-HLW) flowsheet at Hanford. Phase 1 demonstrated a bench-scale proof-of-concept for reactions involving the denitration electrolyzer and gas phase abatement of ammonia. The electrochemical technology is drawing on the scientific outcomes that were reported in the legacy work. The results from Phase 1 demonstrated the viability of the EDCGe system in reducing the nitrogen species of simple non-radioactive waste simulants. Commercially available alloys used as electrode materials and membranes are being studied for the denitration and caustic generation electrolyzers. The continuation of this project holds promise for broader applications, such as energy-efficient ammonia production, and contributes significant advancements in nuclear waste management. Additional material discovery has been investigated into ceramic Na super ion conductive (NaSICON) materials and off-gas abatement catalyst discovery. NaSICON is of interest for selective transport of Na within the electrolyzers to make a clean caustic stream. Future integration and optimization efforts, informed by Phase 1 results and ongoing research, will continue to drive advancements in nuclear waste management technology. The technology developed for the EDCGe treatment of tank waste will also have broader potential to inform other fields, such as energy-efficient ammonia production, as well as ammonia abatement catalysis through the lessons learned in electrochemical nitrate reduction. The applications and benefits of this research extend beyond Hanford and the Savannah River Site, supported by a collaborative team of scientists and engineers from national labs, academia, and industry, ensuring a comprehensive approach to solving complex waste treatment challenges. The team is leveraging advanced electrochemical technologies, machine learning, novel catalysts tailored for gaseous nitrogen species, and cutting-edge reactor systems to enhance the process efficiency and effectiveness of the denitration process.

Rodene, Dylan [Savannah River National Laboratory ↗

Operation of mixed conducting metal oxide membrane systems under transient conditions

Method of operating an oxygen-permeable mixed conducting membrane having an oxidant feed side, an oxidant feed surface, a permeate side, and a permeate surface, which method comprises controlling the differential strain between the permeate surface and the oxidant feed surface at a value below a selected maximum value by varying the oxygen partial pressure on either or both of the oxidant feed side and the permeate side of the membrane.

47 OTHER INSTRUMENTATION↗

Occlusion of Arteriovenous Fistulas of In-Situ Saphenous Vein Bypass Grafts Using the Amplatzer Vascular Plug 4: Initial Experience

We examined the safety and efficacy of vessel occlusion of the Amplatzer Vascular Plug 4 (AVP-4) in patients with arteriovenous fistulas after in-situ saphenous vein bypass grafts. We treated 18 fistulas of seven patients (four women, mean {+-} standard deviation age 76 {+-} 7 years, range 63-88 years). All fistulas were detected within 14 days after surgery. Initial diagnosis and follow-up was established by sonography. We measured the diameter of the feeding vessel and the time of vessel occlusion after plug deployment. Additionally, we recorded procedure time and the dose area product. Additional interventional procedures were necessary in three patients. We successfully used 19 AVP-4 for occlusion of all fistulas without thromboembolic complications. There was no need for recapturing the device, and we did not observe dislocation. Mean occlusion time was 9.6 min (range 5-22 min). Mean diameter of the feeding vessels was 3.5 mm (range 2.6-5.1 mm). Plug sizes ranged from 4-8 mm (mean 5.5 mm) resulting in an oversizing of 33-88%. Mean procedure time for patients with and without additional intervention was 91 {+-} 38 min and 35 {+-} 18 min, respectively. Mean dose area product was 11,790 cGy/cm{sup 2} (range 1,850-23,500 cGy/cm{sup 2}). Permanent occlusion of the fistulas was confirmed by ultrasound after a mean follow-up of 4 months (1-6 months). Occlusion of arteriovenous fistulas with an AVP-4 seems to be effective and safe in patients with in-situ saphenous vein bypass grafts. The AVP-4 is well suited for this purpose because of the appropriate diameter of the feeding vessels.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Chemoembolization for Hepatocellular Carcinoma Supplied by a Lumbar Artery

PurposeTo describe the radiologic findings and imaging response of hepatocellular carcinoma (HCC) supplied by the lumbar artery.MethodsBetween April 2004 and December 2012, we encountered HCC supplied by a lumbar artery in 21 patients. Two investigators retrospectively reviewed clinical and radiological findings of HCC supplied by the lumbar artery using computed tomography (CT) scans and digital subtraction angiograms.ResultsPatients had received 1–27 sessions of previous chemoembolization procedures (mean 7.7 sessions, median 4 sessions). Mean tumor size was 5.3 cm. The locations of HCC supplied by lumbar artery were the bare area (n = 14, 67 %) and segment VI (n = 7, 33 %). Tumor-feeding arteries arose from the main lumbar artery (n = 7), proximal anterior division (n = 4), and distal anterior division (n = 14). In 20 patients, selective chemoembolization through the tumor-feeding arteries of the lumbar artery was achieved. In 1 patient, nonselective embolization at the main lumbar artery was performed. There was no complication such as skin necrosis or paralysis. On the first follow-up enhanced CT scan, target tumors fed by the lumbar artery showed complete response (n = 6), partial response (n = 4), stable disease (n = 3), and progressive disease (n = 8), but overall tumor response was partial response (n = 1) and progressive disease (n = 20).ConclusionWhen HCC is located in the inferior tip or bare area of the liver, a lumbar artery may supply the tumor. Although selective chemoembolization via the tumor-feeding vessel of the lumbar artery can be achieved in most cases, overall tumor response is commonly unfavorable.

62 RADIOLOGY AND NUCLEAR MEDICINE↗