Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXIT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Liquid Sampling-Atmospheric Pressure Glow Discharge (LS-APGD) Ionization Source for Elemental Mass Spectrometry: Preliminary Parametric Evaluation and Figures of Merit

A new, low power ionization source for the elemental analysis of aqueous solutions has recently been described. The liquid sampling-atmospheric pressure glow discharge (LS-APGD) source operates at relatively low currents (<20 mA) and solution flow rates (<50 μL min-1), yielding a relatively simple alternative for atomic mass spectrometry applications. The LS-APGD has been interfaced to what is otherwise an organic, LC-MS mass analyzer, the Thermo Scientific Exactive Orbitrap without any modifications; other than removing the electrospray ionization (ESI) source supplied with that instrument. A glow discharge is initiated between the surface of the test solution exiting a glass capillary and a metallic counter electrode mounted at a 90° angle and separated by a distance of ~5 mm. As with any plasma-based ionization source, there are key discharge operation and ion sampling parameters that affect the intensity and composition of the derived mass spectra; including signal-to-background ratios. We describe here a preliminary parametric evaluation of the roles of discharge current, solution flow rate, argon sheath gas flow rate, and ion sampling distance as they apply on this mass analyzer system. A cursive evaluation of potential matrix effects due to the presence of easily ionized elements (EIEs) indicate that sodium concentrations of up to 500 μg mL-1 generally cause suppressions of less than 50%, dependant upon the analyte species. Based on the results of this series of studies, preliminary limits of detection (LOD) have been established through the generation of calibration functions. Whilst solution-based concentrations LOD levels of 0.02 – 2 μg mL-1 3 are not impressive on the surface, the fact that they are determined via discrete 5 μL injections leads to mass-based detection limits at picogram to singlenanogram levels. The overhead costs associated with source operation (10 W d.c. power, solution flow rates of <50 μL min-1, and gas flow rates <10 mL min-1) are very attractive. While further optimization in the source design is suggested here, it is believed that the LS-APGD ion source may present a practical alternative to inductively-coupled plasma (ICP) sources typically employed in elemental mass spectrometry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Continuous-Time Mean-Variance Portfolio Selection with Random Horizon

This paper examines the continuous-time mean-variance optimal portfolio selection problem with random market parameters and random time horizon. Treating this problem as a linearly constrained stochastic linear-quadratic optimal control problem, I explicitly derive the efficient portfolios and efficient frontier in closed forms based on the solutions of two backward stochastic differential equations. Some related issues such as a minimum variance portfolio and a mutual fund theorem are also addressed. All the results are markedly different from those in the problem with deterministic exit time. A key part of my analysis involves proving the global solvability of a stochastic Riccati equation, which is interesting in its own right.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fluoroscopy-Guided Pull-Through Gastrostomy

The purpose of this study was to simplify a fluoroscopy guided gastrostomy technique using pull-type tubes which are traditionally introduced with gastroscopic assistance. The stomach was transorally probed with a 5-Fr catheter and a guidewire. A second access was performed percutaneously through the anterior abdominal and gastric wall using an 8-Fr sheath and an 8-Fr guiding catheter. A duplicated guidewire was introduced through the guiding catheter in order to result in a great custom-made loop within the stomach. The transoral guidewire was captured and tightened with this loop and the guiding catheter, and both were subsequently pulled by the transoral guidewire until the tip of the guiding catheter exited the mouth. A thread was fed through the guiding catheter for fixation of the pull-type gastrostomy tube. Finally, the fixed tube was pulled through the esophagus into the stomach and through the abdominal wall until the anterior gastric wall fixed the retention plate of the tube. Thirty-seven patients (28 male, 9 female; age, 65.1 {+-} 14.4 years) with miscellaneous indications for percutaneous gastrostomies were supplied with pull-type gastrostomy catheters in a fluoroscopy technique without endoscopic assistance. Twenty-five of the 37 patients (67.6%) had undergone unsuccessful preceding gastroscopically guided PEG attempts because of tumor stenosis (n = 12) or impossible transillumination of the abdominal wall (n = 13). All procedures were technically successful, without major complications. Particularly, all patients with frustrating gastroscopic attempts were successfully provided with pull-type gastrostomy tubes. Five minor complications occurred: one tube loss during the passage of the hypopoharynx because of a torn thread, one transient small leakage alongside the tube (both successfully treated), and three cases of transient moderate local pain without leakage (symptomatic treatment). We conclude that this fluoroscopy-guided pull-through gastrostomy technique is easy and safe to perform and may be suggested as a standard procedure for radiological gastrostomies. It combines the ease of the radiological approach with the advantages of the pull-type tube devices, particularly the benefits of the typical retention plates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Improved Accuracy of Percutaneous Biopsy Using “Cross and Push” Technique for Patients Suspected with Malignant Biliary Strictures

PurposeVarious methods have been used to sample biliary strictures, including percutaneous fine-needle aspiration biopsy, intraluminal biliary washings, and cytological analysis of drained bile. However, none of these methods has proven to be particularly sensitive in the diagnosis of biliary tract malignancy. We report improved diagnostic accuracy using a modified technique for percutaneous transluminal biopsy in patients with this disease.Materials and MethodsFifty-two patients with obstructive jaundice due to a biliary stricture underwent transluminal forceps biopsy with a modified “cross and push” technique with the use of a flexible biopsy forceps kit commonly used for cardiac biopsies. The modification entailed crossing the stricture with a 0.038-in. wire leading all the way down into the duodenum. A standard or long sheath was subsequently advanced up to the stricture over the wire. A Cook 5.2-Fr biopsy forceps was introduced alongside the wire and the cup was opened upon exiting the sheath. With the biopsy forceps open, within the stricture the sheath was used to push and advance the biopsy cup into the stricture before the cup was closed and the sample obtained. The data were analysed retrospectively.ResultsWe report the outcomes of this modified technique used on 52 consecutive patients with obstructive jaundice secondary to a biliary stricture. The sensitivity and accuracy were 93.3 and 94.2 %, respectively. There was one procedure-related late complication.ConclusionWe propose that the modified “cross and push” technique is a feasible, safe, and more accurate option over the standard technique for sampling strictures of the biliary tree.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two Wire System and Modified Olive Tip to Facilitate Implantation of Fenestrated TEVAR in Patient with Proximal Descending Aortic Pathology: First Two Cases

Introduction: Although Fenestrated TEVAR (F-TEVAR) has been considered to be a more physiologic approach to treat proximal descending aortic pathology, its application is still limited due to availability, cost and technical difficulties. We introduce a new design of fenestrated stent graft with a new delivery system and successfully performed first in human implantation in two patients, one with an aortic aneurysm and one with an acute aortic dissection. Materials and Methods: The design of these two wires fenestrated stent graft include creation of an additional lumen at the side of the olive tip during manufacture, from which an additional wire can be introduced for a side branch passing into the fenestration, running inside the stent graft and exit the delivery sheath through additional hub. The two wires will facilitate delivery and deployment of the stent graft. One patient with descending aortic aneurysm and another with Stanford B aortic dissection is included in this first in human study. Results: The aneurysm and dissection were completely excluded immediately after the TEVAR. Six month follow up CT showed good position of the stent graft and patent LSA in both patients. In the patient with aortic dissection, expansion of the true lumen and partial thrombosis of the false lumen was seen. Conclusions: This is a report of a two wire system in 2 patients with distal aortic arch pathology demonstrating a good technical and clinical success using pre-cannulated fenestrations through a modified nose cone olive. Level of Evidence: Level 4, report of two cases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Synthesis of convection velocity and turbulence measurements in three-stream jets

Key flow regions linked to jet noise sources are investigated through comparison of convection velocity and turbulence measurements in high-speed three-stream nozzles. Time-resolved flow imaging using a photomultiplier tube array was applied in the Nozzle Acoustic Test Rig at NASAs Aero-Acoustic Propulsion Lab to measure 250 kHz repetition laser scattering signals arising from seeding particles at 32 points in high-speed flow. Particle image velocimetry measurements previously reported by NASA provided mean velocity and turbulence intensity. Results for convection velocity of the particle concentration field were obtained from the time-resolved data for three-stream nozzle configurations using a cross-correlation approach. The three-stream cases included an axisymmetric and an asymmetric, offset nozzle configuration. For the axisymmetric case, areas of high convection velocity and turbulence intensity were found to occur 4–6 area-equivalent nozzle diameters downstream from the nozzle exit. Comparison of convection velocity between the axisymmetric and offset cases shows this same region as having the greatest reduction in convection velocity due to the offset, up to 20% reduction for the offset case compared to the axisymmetric case. Finally, these findings suggest that this region along the centerline near the end of the potential core is an important area for noise generation with jets and contributes to the noise reductions seen from three-stream offset nozzles.

33 ADVANCED PROPULSION SYSTEMS↗

Dot tracking methodology for background-oriented schlieren (BOS)

We propose here a dot tracking methodology for processing background-oriented schlieren (BOS) images. The technique improves the accuracy, precision and spatial resolution compared to conventional cross-correlation algorithms. Our methodology utilizes the prior information about the dot pattern such as the location, size and number of dots to provide near 100% yield even for high dot densities (20 dots/32 × 32 pixels) and is robust to image noise. Furthermore, we propose an improvement to the displacement estimation step in the tracking process, especially for noisy images, using a “correlation correction”, whereby we combine the spatial resolution benefit of the tracking method and the smoothing property of the correlation method to increase the dynamic range of the overall measurement process. We evaluate the performance of the method with synthetic BOS images of buoyancy-driven turbulence rendered using ray-tracing simulations, and experimental images of flow in the exit plane of a converging–diverging nozzle. The results show that the improved spatial resolution results in a better accuracy of the tracking method compared to correlation-based methods in regions with sharp displacement gradients, and the correlation correction step reduces the noise floor of the measurement, resulting in a fourfold improvement in the dynamic range.

42 ENGINEERING↗

Ascent and emplacement dynamics of obsidian lavas inferred from microlite textures

Here, to assess the eruption and emplacement of volumetrically diverse rhyolite lavas, we measured microlite number densities and orientations from samples collected from nine lavas in Yellowstone Caldera and two from Mono Craters, USA. Microlite populations are composed of Fe-Ti oxides ± alkali feldspar ± clinopyroxene. Number densities range from 10 8.11 ± 0.03 to 10 9.45 ± 0.15 cm -3 and do not correlate with distance from the vent across individual flows and are remarkably similar between large- and small-volume lavas. Together, those observations suggest that number densities are unmodified during emplacement and that ascent rates in the conduit are similar between small domes and large lava flows. Microtextures produced by continuous decompression experiments best replicate natural textures at decompression rates of 1–2 MPa hr -1 . Acicular microlites have a preferred orientation in all natural samples. Because the standard deviation of microlite orientation does not become better aligned with distance travelled, we conclude that microlites exit the conduit aligned and that strain during subaerial flow was insufficient to further align microlites. The orientations of microlite trend and plunge in near-vent samples indicate that pure shear was the dominant style of deformation in the conduit. In conclusion, we speculate that collapsing permeable foam(s) provides a mechanism to concurrently allow microlite formation and alignment in response to the combination of degassing and flattening by pure shear.

58 GEOSCIENCES↗

Groundwater drainage from fissures as a source for lahars

One mechanism for generating lahars at volcanoes experiencing unrest is the disruption of internal aquifers. These disruptions can trigger releases of large quantities of groundwater. An example of such aquifer disruption occurred at Nevado del Huila Volcano, Colombia, during February and April 2007 when large fractures formed across the summit area of the volcano and lahars were emitted from them. Previous work interpreted that lahar volumes could not be accounted for by melted glacial snow or precipitation, and by elimination suggested that the primary water source was groundwater. Conceptual models have been developed for perched, confined aquifers that have been heated and pressurized by magma intrusions, followed by sudden pressure release and water emission during fracture formation. In this paper, we consider an alternative end member wherein water release from large fissures at volcanoes is driven by simple gravity drainage. We apply numerical modeling to quantify water discharge from the porous medium surrounding a fissure with a low-elevation free exit. If a long fracture with high vertical extent (on the order of hundreds of meters) intersects a highly connected saturated porous medium, large volumes (on order 10 3 m 3 /m of crack length) of water may be released within tens of minutes. The drainage rates from the model may be adequate to account for the Nevado del Huila events if the medium surrounding the crack contains a large volume of water and has high horizontal permeability. Finally, this simple but poorly understood mechanism can present a hazard on its own or compound other processes releasing water from volcanoes.

58 GEOSCIENCES↗

Structural features promoting dioxygen production by Dechloromonas aromatica chlorite dismutase

Chlorite dismutase (Cld) is a heme enzyme capable of rapidly and selectively decomposing chlorite (ClO{sub 2}{sup -}) to Cl{sup -} and O{sub 2}. The ability of Cld to promote O{sub 2} formation from ClO{sub 2}{sup -} is unusual. Heme enzymes generally utilize ClO{sub 2}{sup -} as an oxidant for reactions such as oxygen atom transfer to, or halogenation of, a second substrate. The X-ray crystal structure of Dechloromonas aromatica Cld co-crystallized with the substrate analogue nitrite (NO{sub 2}{sup -}) was determined to investigate features responsible for this novel reactivity. The enzyme active site contains a single b-type heme coordinated by a proximal histidine residue. Structural analysis identified a glutamate residue hydrogen-bonded to the heme proximal histidine that may stabilize reactive heme species. A solvent-exposed arginine residue likely gates substrate entry to a tightly confined distal pocket. On the basis of the proposed mechanism of Cld, initial reaction of ClO{sub 2}{sup -} within the distal pocket generates hypochlorite (ClO{sup -}) and a compound I intermediate. The sterically restrictive distal pocket probably facilitates the rapid rebound of ClO{sup -} with compound I forming the Cl{sup -} and O{sub 2} products. Common to other heme enzymes, Cld is inactivated after a finite number of turnovers, potentially via the observed formation of an off-pathway tryptophanyl radical species through electron migration to compound I. Three tryptophan residues of Cld have been identified as candidates for this off-pathway radical. Finally, a juxtaposition of hydrophobic residues between the distal pocket and the enzyme surface suggests O{sub 2} may have a preferential direction for exiting the active site.

36 MATERIALS SCIENCE↗

Biomanufacturing: history and perspective

Abstract Biomanufacturing is a type of manufacturing that utilizes biological systems (e.g., living microorganisms, resting cells, animal cells, plant cells, tissues, enzymes, or in vitro synthetic (enzymatic) systems) to produce commercially important biomolecules for use in the agricultural, food, material, energy, and pharmaceutical industries. History of biomanufacturing could be classified into the three revolutions in terms of respective product types (mainly), production platforms, and research technologies. Biomanufacturing 1.0 focuses on the production of primary metabolites (e.g., butanol, acetone, ethanol, citric acid) by using mono-culture fermentation; biomanufacturing 2.0 focuses on the production of secondary metabolites (e.g., penicillin, streptomycin) by using a dedicated mutant and aerobic submerged liquid fermentation; and biomanufacturing 3.0 focuses on the production of large-size biomolecules—proteins and enzymes (e.g., erythropoietin, insulin, growth hormone, amylase, DNA polymerase) by using recombinant DNA technology and advanced cell culture. Biomanufacturing 4.0 could focus on new products, for example, human tissues or cells made by regenerative medicine, artificial starch made by in vitro synthetic biosystems, isobutanol fermented by metabolic engineering, and synthetic biology-driven microorganisms, as well as exiting products produced by far better approaches. Biomanufacturing 4.0 would help address some of the most important challenges of humankind, such as food security, energy security and sustainability, water crisis, climate change, health issues, and conflict related to the energy, food, and water nexus.

Zhang, Yi-Heng Percival↗

Experimental Studies of Coolant Temperature and Velocity on an Integrated Water Model of a Fast Reactor in Different Operating Regimes

The results of experimental studies of a next-generation fast reactor performed using an integrated water model (scale 1:10) are presented: local velocity over height and radius of the top chamber in a plane in a direction from core center to the intermediate heat exchangers and coolant temperature in the top chamber and other elements of the circulation loop with forced circulation and emergency cool-down by natural convection. The data were obtained using a specially designed system for performing measurements which is incorporated in the bench and provides high accuracy and rate of acquisition. Stable temperature stratification of the coolant is observed in the top, cold, and pressure chambers of the reactor, elevator enclosure, and reactor vessel cooling system as well as at the exit from the intermediate and autonomous heat exchangers in different operating regimes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Modeling of Gas Dynamic Processes in the Interelectrode Gap of a Multielement Thermionic Electricity Generating Channel by Solving the Kinetic Equation

This work is devoted to the application of a numerical method of solving Boltzmann’s equation for modeling the behavior of radionuclides (Kr, Xe, Rb, Sr, Cs, Ba) in the cavity of the interelectrode gap of a multielement electricity generating channel. Modeling methods were developed and software system implemented in the course of this work. Calculations were performed for two structural arrangements: with uni- and bilateral extraction of radionuclides into the vacuum-cesium system. Data on the pressure and flow distributions were obtained. The krypton and xenon pressure near the collector as functions of their flow and the cesium gas pressure at the gap exits were determined computationally.

07 ISOTOPE AND RADIATION SOURCES↗

Methanol Production Based on Direct-Flow Gas Generator and Nuclear Reactor

A nuclear technological complex for producing liquid fuel (methanol) from synthesis gas, obtained in a direct-flow gas generator from coal obtained from the Borodinskoe deposit, is presented. The thermal energy required for the process is delivered from a nuclear reactor with liquid-metal coolant at temperature 700°C. A water-coal suspension with coal-to-water mass ratio 1:4 is delivered into the gas generator along a spiral coil placed in a ring casing into which the warming coolant from the nuclear reactor is delivered. Material and thermal balance of the gas generator is obtained. The synthesis gas at the exit from the gas generator passes through a purification apparatus. Methanol is obtained on a copper catalyst in a circulation reactor at pressure 3 MPa and temperature 270°C. The power of the nuclear reactor is 100 MW. The capacity of the complex is 248 tons/day of methanol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A New Candidate Laser Dye Based 1,4-Bis[β-(2-Naphthothiazolyle)Vinyl]Benzene. Spectroscopic Behavior, Laser Parameters and Excitation Energy Transfer

A new candidate laser dye based 1,4-bis[β-(2-naphthothisolyl) vinyl] benzene (BNTVB) were prepared, and characterized in various organic solvents. The center polarity is less sensitive than electronic absorption. A red shift was noticed in the fluorescence spectra (ca. 40 nm) with increment in the solvent’s polarity, this means that BNTVB’s polarity appreciates upon excitation. The dipole moment of ground state (μ{sub g}) and the excited singlet state dipole moment (μ{sub e}) are determined from Kawski – Chamma and Bakshiev–Viallet equations using the disparity of Stokes shift with solvent polarity function of ε (dielectric constant) and n (refractive index) of the solvent. The result was found to be 0.019D and 5.13D for ground and exited state, in succession. DFT/TD-DFT manners were used to understand the electronic structures and geometric of BNTVB in other solvents. The experimental and theoretical results showed a good agreement. The photochemical quantum yield (Ф{sub c}) of BNTVB was calculated in variable organic reagents such as Dioxane, CHCl{sub 3}, EtOH and MeOH at room temperature. The values of φ{sub c} were calculated as 2.3 × 10{sup −4}, 3.3 × 10{sup −3}, 9.7 × 10{sup −5} and 6.2 × 10{sup −5} in Dioxane, CHCl{sub 3}, EtOH and MeOH, respectively. The dye solutions (2 × 10{sup −4} M) in DMF, MeOH and EtOH give laser emission in the blue-green region. The green zone is excited by nitrogen pulse 337.1 nm. The tuning range, gain coefficient (α) and cross – section emission (σ{sub e}) of laser were also estimated. Excitation energy transfer from BNTVB to rhodamine-6G (R6G) and N,N-bis(2,6-dimethyphenyl)-3,4:9,10-perylenebis-(dicarboximide) (BDP) was also studied in EtOH to increase the laser emission output from R6G and BDP when excited by nitrogen laser. The dye-transfer power laser system (ETDL) obeys the Foster Power Transmission (FERT) mechanism with a critical transmission distance, R{sub o} of 40 and 32 A and k{sub ET} equals 2.6 × 10{sup 13} and 1.06 × 10{sup 13} M{sup −1} s{sup −1} for BNTVB / R6G and BNTVB / BDP pair, respectively.

74 ATOMIC AND MOLECULAR PHYSICS↗

Infinite Geodesics in the Discrete Heisenberg Group

We give an exhaustive description of the family of infinite geodesics in the discrete Heisenberg group (with respect to the standard generating set). The classification of infinite geodesics is needed to describe the so-called absolute (exit boundary) of a group. The absolute of the discrete Heisenberg group will be described in a forthcoming paper.

97 MATHEMATICS AND COMPUTING↗

Teleportation two-qubit state by using two different protocols

In this contribution, two versions of teleportation protocol are considered, based on either using a single or two copies of entangled atom-field state, respectively. It is shown that, by using the first version, the fidelity of the teleported state as well as the amount of quantum Fisher information, that contains in the teleported state, are much better than using the second version. In general, one may increases the fidelity of teleported information by increasing the mean photon number and decreasing the detuning parameter. The fidelity of teleporting classical information is much better than teleporting quantum information. Moreover, teleportating classical information that initially encoded in an exited states is much better than that encodes in the ground states. However, the teleported Fisher information that initially encoded in a ground state is much larger than those initially encoded in entangled states.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Two-color terahertz interferometer based on the frequency-splitted orthogonal polarization modes of the water vapor laser and designed for measuring the electron density profile in the L-2M stellarator

An upgraded diagnostics for measuring the electron density profile in the L-2M stellarator is proposed. The existing diagnostics employs an interferometer based on an HCN laser with a mechanical frequency shifter and unmagnetized InSb detectors cooled with liquid helium. It is proposed to replace the HCN laser with a water vapor laser operating simultaneously at two wavelengths (220 and 118 {mu}m). Being equipped with an anisotropic exit mirror, the water vapor laser allows the generation of orthogonally polarized, frequency-splitted modes at each of these wavelengths with a frequency difference of several tens of kilohertzs. Such a scheme makes it possible to get rid of the mechanical frequency shifter. Moreover, simultaneous measurements at two wavelengths allow one to reliably separate the phase increments introduced by the plasma electron component and by variations in the lengths of the interferometer arms. To take full advantage of this scheme, specially developed cryogenic receivers consisting of Ge and InSb photodetectors placed one after another will be used. To increase the response of the system near {lambda} = 220 {mu}m, the InSb detector is placed in a {approx}0.55-T magnetic field.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗