Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Direct Simulation Monte Carlo”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Performance Considerations for the SIMPL Single Photon, Polarimetric, Two-Color Laser Altimeter as Applied to Measurements of Forest Canopy Structure and Composition

The Slope Imaging Multi-polarization Photon-counting Lidar (SIMPL) is a multi-beam, micropulse airborne laser altimeter that acquires active and passive polarimetric optical remote sensing measurements at visible and near-infrared wavelengths. SIMPL was developed to demonstrate advanced measurement approaches of potential benefit for improved, more efficient spaceflight laser altimeter missions. SIMPL data have been acquired for wide diversity of forest types in the summers of 2010 and 2011 in order to assess the potential of its novel capabilities for characterization of vegetation structure and composition. On each of its four beams SIMPL provides highly-resolved measurements of forest canopy structure by detecting single-photons with 15 cm ranging precision using a narrow-beam system operating at a laser repetition rate of 11 kHz. Associated with that ranging data SIMPL provides eight amplitude parameters per beam unlike the single amplitude provided by typical laser altimeters. Those eight parameters are received energy that is parallel and perpendicular to that of the plane-polarized transmit pulse at 532 nm (green) and 1064 nm (near IR), for both the active laser backscatter retro-reflectance and the passive solar bi-directional reflectance. This poster presentation will cover the instrument architecture and highlight the performance of the SIMPL instrument with examples taken from measurements for several sites with distinct canopy structures and compositions. Specific performance areas such as probability of detection, after pulsing, and dead time, will be highlighted and addressed, along with examples of their impact on the measurements and how they limit the ability to accurately model and recover the canopy properties. To assess the sensitivity of SIMPL's measurements to canopy properties an instrument model has been implemented in the FLIGHT radiative transfer code, based on Monte Carlo simulation of photon transport. SIMPL data collected in 2010 over the Smithsonian Environmental Research Center, MD are currently being modelled and compared to other remote sensing and in situ data sets. Results on the adaptation of FLIGHT to model micropulse, single'photon ranging measurements are presented elsewhere at this conference. NASA's ICESat-2 spaceflight mission, scheduled for launch in 2016, will utilize a multi-beam, micropulse, single-photon ranging measurement approach (although non-polarimetric and only at 532 nm). Insights gained from the analysis and modelling of SIMPL data will help guide preparations for that mission, including development of calibration/validation plans and algorithms for the estimation of forest biophysical parameters.

Dabney, Philip W.↗

Comparison of spherical harmonics method and discrete ordinates method for radiative transfer in a turbulent jet flame

Here, in this study, we systematically compared the accuracy and computational cost of two popular solution methods for the radiative transfer equation (RTE): the spherical harmonics method (P N ) and the discrete ordinates method (DOM). We first investigated convergence characteristics of different orders of P N and DOM in a series of 1D homogeneous configurations with varying optical thicknesses. Both solvers perform better for optically thicker cases. The accuracy of P N methods increases with its order, , but the gain in accuracy reduces with the increase in , i.e., improvement of P 7 over P 5 is less than that of P 3 over P 1 . This decreasing trend becomes more prominent as the optical thickness decreases. On the other hand, DOM’s accuracy increases almost linearly with the increase in the number of ordinates (or polar angles in this study) in all cases. While comparing the directional profile of radiative intensity, both solvers perform better when the radiative intensity is more isotropic. These solvers were then connected with a full spectrum k-distribution (FSK) spectral model and used to perform radiation-coupled simulations of a turbulent jet flame in an axi-symmetric cylindrical domain. Results obtained from P 1 to P 7 approximations for P N , and 2 x 4, 4 x 4, 4 x 8, 8 x 8 finite angles for DOM are compared with that from an optically thin model, and a reference solution from line-by-line (LBL) photon Monte Carlo (PMC) method. The choice of radiation solver shows a noticeable impact on the temperature distribution of the flame. The P N solvers lead to slightly higher radiant fractions and the DOM solvers lead to slightly lower radiant fractions than the PMC benchmark solution. Finally, the computational costs of each of these solvers are also reported and an intermittent evaluation / time blending scheme to improve the computational efficiency of radiation solvers in radiation-coupled simulations are also demonstrated.

42 ENGINEERING↗

Looking for Auger signatures in III-nitride light emitters: A full-band Monte Carlo perspective

Recent experiments of electron emission spectroscopy (EES) on III-nitride light-emitting diodes (LEDs) have shown a correlation between droop onset and hot electron emission at the cesiated surface of the LED p-cap. The observed hot electrons have been interpreted as a direct signature of Auger recombination in the LED active region, as highly energetic Auger-excited electrons would be collected in long-lived satellite valleys of the conduction band so that they would not decay on their journey to the surface across the highly doped p-contact layer. We discuss this interpretation by using a full-band Monte Carlo model based on first-principles electronic structure and lattice dynamics calculations. The results of our analysis suggest that Auger-excited electrons cannot be unambiguously detected in the LED structures used in the EES experiments. Additional experimental and simulative work are necessary to unravel the complex physics of GaN cesiated surfaces.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effects of low-frequency voltage on nonlinear standing wave excitation, plasma uniformity, and ion dynamics in dual-frequency asymmetric capacitive discharges

Abstract It is known that in very-high-frequency (VHF) capacitively coupled plasmas, the higher harmonics generated by nonlinear sheath motion can enhance the standing wave effect (SWE), which can lead to center-peaked plasma density profiles. In this work, an improved nonlinear electromagnetic model incorporating a transmission line model, an electron momentum balance model, a bulk plasma model, a collisionless nonlinear numerical sheath model, and an ion Monte-Carlo collision (MCC) model is developed to study the effects of low-frequency (LF) voltage V L on the nonlinear standing wave excitation, plasma uniformity, and ion energy and angular distribution functions (IEDFs and IADFs) in dual-frequency (DF) asymmetric capacitive argon discharges at relatively low pressure of 3 Pa. The plasma diffusion in the radial direction and ion dynamics within the LF oscillating sheath are self-consistently considered. The LF voltage V L at 2 MHz varies from 0 to 700 V while the HF voltage V H at 60 MHz is fixed at 100 V. Simulation results indicate that without the addition of an LF source (i.e. V L = 0 V), there are a considerable number of high-order harmonics with short wavelengths, leading to significant SWE and central peak in the radial plasma density profile. Nevertheless, the high-order harmonic excitations tend to be weakened and merely occur around the phase of the full LF sheath collapse due to a shorter characteristic damping time of the surface waves as V L increases. This, combined with increased surface wavelengths of both the driving frequency and the higher harmonics at a higher V L , leads to suppressed standing waves and improved plasma uniformity. Meanwhile, the simulations show that both the low and the high energy peaks of IEDF move towards higher energies, and the energy peak separation width ΔEbecomes wider with the increase of V L . The IEDF at the radial center of the powered electrode exhibits a broader ΔEthan that at the edge. For the IADF, an increased V L results in more ions incident on the electrode with a smaller deflection angle. Because of a thinner sheath and a higher sheath voltage at the electrode center, the peak value of IADF at the electrode center is greater than that at the edge.

Physics↗

SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target were also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose.

60 APPLIED LIFE SCIENCES↗

An Exploratory Exercise in Taguchi Analysis of Design Parameters: Application to a Shuttle-to-space Station Automated Approach Control System

The chief goals of the summer project have been twofold - first, for my host group and myself to learn as much of the working details of Taguchi analysis as possible in the time allotted, and, secondly, to apply the methodology to a design problem with the intention of establishing a preliminary set of near-optimal (in the sense of producing a desired response) design parameter values from among a large number of candidate factor combinations. The selected problem is concerned with determining design factor settings for an automated approach program which is to have the capability of guiding the Shuttle into the docking port of the Space Station under controlled conditions so as to meet and/or optimize certain target criteria. The candidate design parameters under study were glide path (i.e., approach) angle, path intercept and approach gains, and minimum impulse bit mode (a parameter which defines how Shuttle jets shall be fired). Several performance criteria were of concern: terminal relative velocity at the instant the two spacecraft are mated; docking offset; number of Shuttle jet firings in certain specified directions (of interest due to possible plume impingement on the Station's solar arrays), and total RCS (a measure of the energy expended in performing the approach/docking maneuver). In the material discussed here, we have focused on single performance criteria - total RCS. An analysis of the possibility of employing a multiobjective function composed of a weighted sum of the various individual criteria has been undertaken, but is, at this writing, incomplete. Results from the Taguchi statistical analysis indicate that only three of the original four posited factors are significant in affecting RCS response. A comparison of model simulation output (via Monte Carlo) with predictions based on estimated factor effects inferred through the Taguchi experiment array data suggested acceptable or close agreement between the two except at the predicted optimum point, where a difference outside a rule-of-thumb bound was observed. We have concluded that there is most likely an interaction effect not provided for in the original orthogonal array selected as the basis for our experimental design. However, we feel that the data indicates that this interaction is a mild one and that inclusion of its effect will not alter the location of the optimum.

Deal, Don E.↗

Inflation of Unreefed and Reefed Extraction Parachutes

Data from the Orion and several other test programs have been used to reconstruct inflation parameters for 28 ft Do extraction parachutes as well as the parent aircraft pitch response during extraction. The inflation force generated by extraction parachutes is recorded directly during tow tests but is usually inferred from the payload accelerometer during Low Velocity Airdrop Delivery (LVAD) flight test extractions. Inflation parameters are dependent on the type of parent aircraft, number of canopies, and standard vs. high altitude extraction conditions. For standard altitudes, single canopy inflations are modeled as infinite mass, but the non-symmetric inflations in a cluster are modeled as finite mass. High altitude extractions have necessitated reefing the extraction parachutes, which are best modeled as infinite mass for those conditions. Distributions of aircraft pitch profiles and inflation parameters have been generated for use in Monte Carlo simulations of payload extractions.

Ray, Eric S.↗

Three-dimensional, off-lattice Monte-Carlo kinetics simulations of interstellar grain chemistry and ice structure

The first off-lattice Monte Carlo kinetics model of interstellar dust grain surface chemistry is presented. The positions of all surface particles are determined explicitly, according to the local potential minima resulting from the pair-wise interactions of contiguous atoms and molecules, rather than by a pre-defined lattice structure. The model is capable of simulating chemical kinetics on any arbitrary dust grain morphology, as determined by the user-defined positions of each individual dust grain atom. A simple method is devised for the determination of the most likely diffusion pathways and their associated energy barriers for surface species. The model is applied to a small, idealized dust grain, adopting various gas densities and using a small chemical network. Hydrogen and oxygen atoms accrete onto the grain to produce H{sub 2}O, H{sub 2}, O{sub 2}, and H{sub 2}O{sub 2}. The off-lattice method allows the ice structure to evolve freely; the ice mantle porosity is found to be dependent on the gas density, which controls the accretion rate. A gas density of 2 × 10{sup 4} cm{sup –3}, appropriate for dark interstellar clouds, is found to produce a fairly smooth and non-porous ice mantle. At all densities, H{sub 2} molecules formed on the grains collect within the crevices that divide nodules of ice and within micropores (whose extreme inward curvature produces strong local potential minima). The larger pores produced in the high-density models are not typically filled with H{sub 2}. Direct deposition of water molecules onto the grain indicates that amorphous ices formed in this way may be significantly more porous than interstellar ices that are formed by surface chemistry.

79 ASTRONOMY AND ASTROPHYSICS↗

Examination of synthetic gas puff imaging diagnostic data from a gyrokinetic turbulence code

A synthetic gas puff imaging (GPI) diagnostic has been developed for the purpose of validating the three-dimensional gyrokinetic turbulence code XGC. The synthetic diagnostic is described and applied to XGC simulations of two Alcator C-Mod discharges. The turbulence characteristics deduced from the resulting simulated GPI frames, using analysis techniques similar to those applied to experimental data, are compared with locally derived characteristics extracted directly from the XGC output. The comparison of the two is shown to be potentially impacted by misalignment between the GPI view and the magnetic field, the dependence of the light emission on the electron density and temperature, and spatial and temporal variations in the neutral gas cloud induced by the turbulent plasma fluctuations. We conclude that quantitative and, in some cases even qualitative, validation of turbulence simulations need to account for these effects. While we cannot directly compare our results with experimental data due to the absence of high quality GPI data from the shots and times simulated by XGC, we do relate the overall characteristics obtained from the synthetic GPI analysis to published Alcator C-Mod GPI data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

ADVANTG Results for a Proposed NDA System for Detecting Pin Diversion from SNF - Paper 120

This summary describes the results of applying the ADVANTG variance reduction parameter generator to accelerate continuous-energy Monte Carlo simulations of the {sup 252}Cf Interrogation with Prompt Neutron (CIPN) detection system proposed by Hu et al. for detecting the diversion of fuel elements from spent nuclear fuel (SNF) assemblies. In previous work, ADVANTG was applied to a suite of nine radiation detection, special nuclear material (SNM) movement detection, and safeguards test cases. That effort demonstrated that ADVANTG was able to provide large increases in tally figures of merit (FOMs) in nearly all of the cases without introducing bias into the Monte Carlo results. The objective of the work described here is to further evaluate ADVANTG, and also to identify gaps in capability with regard to nuclear safeguards applications, by applying the code to a challenging problem that is of a different nature from the ones previously studied. The CIPN nondestructive assay (NDA) system consists of three fission chambers embedded in a C-shaped block of polyethylene and a polyethylene-moderated {sup 252}Cf source that are placed on opposite sides of a subject SNF assembly. The idea of the detection system is to measure the difference between the background neutron count rate, due to spontaneous fission in the fuel material, and the count rate observed once the source is introduced, which is dominated by multiplication within the assembly. Based on the difference between these count rates, the fissile content of the assembly can be inferred, and this information can be used to determine if some fraction of the original fuel pins have been replaced with depleted uranium substitutes. The authors report that the system can detect the replacement of at least eight pins (3% of total mass). The ADVANTG code generates space- and energy-dependent weight-window bounds and biased source distributions based on approximate transport solutions that are efficiently generated by the Denovo 3-D discrete ordinates package. ADVANTG implements the Consistent Adjoint Driven Importance Sampling (CADIS) method for accelerating individual tallies and the Forward-Weighted CADIS (FW-CADIS) method for obtaining relatively uniform uncertainties across tallies over multiple regions and/or energy bins. The variance reduction parameters are generated in a format directly usable by standard versions of MCNP5 and MCNPX. In this work, the ADVANTG variance reduction parameter generator was applied to accelerate continuous energy MCNPX simulations of the {sup 252}Cf Interrogation with Prompt Neutron detection system for detecting the diversion of fuel elements from SNF assemblies. Variance reduction parameters generated with the existing version of ADVANTG actually slowed down tally convergence in all cases. The cause of the poor performance was found to be the lack of an induced fission source treatment in the fixed-source discrete ordinates calculations employed by ADVANTG. Because fission was treated as capture and not as a source, the importance maps generated by ADVANTG significantly underestimated the importance of thermal neutrons in and around the fuel elements. In order to obtain improved results, we developed an experimental implementation of a fission source outer iteration for the adjoint calculations. We used this prototype capability to generate new variance reduction parameters and found that the mean fission rates agreed well with those predicted by the conventional MCNPX simulations, as was expected. With these new parameters, speedup factors of 59 to 80 were obtained for the case with the background source, and factors of 17 to 24 were obtained for the cases with the interrogating source. These results demonstrate that a fission source treatment is needed to improve the effectiveness of ADVANTG in problems where the effects of induced fission are important. This includes many types of NDA problems that are relevant to safeguards applications. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

MO-G-BRE-01: A Real-Time Virtual Delivery System for Photon Radiotherapy Delivery Monitoring

Purpose: Treatment delivery monitoring is important for radiotherapy, which enables catching dosimetric error at the earliest possible opportunity. This project develops a virtual delivery system to monitor the dose delivery process of photon radiotherapy in real-time using GPU-based Monte Carlo (MC) method. Methods: The simulation process consists of 3 parallel CPU threads. A thread T1 is responsible for communication with a linac, which acquires a set of linac status parameters, e.g. gantry angles, MLC configurations, and beam MUs every 20 ms. Since linac vendors currently do not offer interface to acquire data in real time, we mimic this process by fetching information from a linac dynalog file at the set frequency. Instantaneous beam fluence map (FM) is calculated. A FM buffer is also created in T1 and the instantaneous FM is accumulated to it. This process continues, until a ready signal is received from thread T2 on which an inhouse developed MC dose engine executes on GPU. At that moment, the accumulated FM is transferred to T2 for dose calculations, and the FM buffer in T1 is cleared. Once the calculation finishes, the resulting 3D dose distribution is directed to thread T3, which displays it in three orthogonal planes overlaid on the CT image for treatment monitoring. This process continues to monitor the 3D dose distribution in real-time. Results: An IMRT and a VMAT cases used in our patient-specific QA are studied. Maximum dose differences between our system and treatment planning system are 0.98% and 1.58% for the two cases, respectively. The average time per MC calculation is 0.1sec with <2% relative uncertainty. The update frequency of ∼10Hz is considered as real time. Conclusion: By embedding a GPU-based MC code in a novel data/work flow, it is possible to achieve real-time MC dose calculations to monitor delivery process.

60 APPLIED LIFE SCIENCES↗

MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor.

60 APPLIED LIFE SCIENCES↗

Simulated scatter performance of an inverse-geometry dedicated breast CT system

The purpose of this work was to quantify the effects of scatter for inverse-geometry dedicated breast CT compared to cone-beam breast CT through simulations. The inverse geometry was previously proposed as an alternative to cone-beam acquisition for volumetric CT. The inverse geometry consists of a large-area scanned-source opposite a detector array that is smaller in the transverse direction. While the gantry rotates, the x-ray beam is rapidly sequenced through an array of positions, acquiring a truncated projection image at each position. Inverse-geometry CT (IGCT) is expected to detect less scatter than cone-beam methods because only a fraction of the object is irradiated at any time and the fast detector isolates the measurements from sequential x-ray beams. An additional scatter benefit is the increased air gap due to the inverted geometry. In this study, we modeled inverse-geometry and cone-beam dedicated breast CT systems of equivalent resolution, field of view, and photon fluence. Monte Carlo simulations generated scatter and primary projections of three cylindrical phantoms of diameters 10, 14, and 18 cm composed of 50% adipose/50% glandular tissue. The scatter-to-primary ratio (SPR) was calculated for each breast diameter. Monte Carlo simulations were combined with analytical simulations to generate inverse-geometry and cone-beam images of breast phantoms embedded with tumors. Noise representing the photon fluence of a realistic breast CT scan was added to the simulated projections. Cone-beam data were reconstructed with and without an ideal scatter correction. The CNR between breast tumor and background was compared for the inverse and cone-beam geometries for the three phantom diameters. Results demonstrated an order of magnitude reduction in SPR for the IGCT system compared to the cone-beam system. For example, the peak IGCT SPRs were 0.05 and 0.09 for the 14 and 18 cm phantoms, respectively, compared to 0.42 and 1 for the cone-beam system. For both geometries, the effects of scatter on contrast-to-noise ratio (CNR) were small for the 10 cm diameter phantom. The inverse-geometry improved the CNR by factors of 1.16 for the 14 cm phantom and 1.48 for the 18 cm phantom compared to a cone-beam acquisition without scatter correction. When an ideal scatter correction was applied to the cone-beam acquisition, the IGCT CNR improvements were 1.03 and 1.25 for the 14 and 18 cm phantoms. Overall, the results suggest that the inverse geometry may be advantageous for dedicated breast CT, an application that requires high-contrast resolution, spatial resolution, and dose efficiency.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-JeP3-06: Lower KV Image Dose Are Expected From a Limited-Angle Intra-Fractional Verification (LIVE) System for SBRT Treatments

Purpose: In order to track the tumor movement for patient positioning verification during arc treatment delivery or in between 3D/IMRT beams for stereotactic body radiation therapy (SBRT), the limited-angle kV projections acquisition simultaneously during arc treatment delivery or in-between static treatment beams as the gantry moves to the next beam angle was proposed. The purpose of this study is to estimate additional imaging dose resulting from multiple tomosynthesis acquisitions in-between static treatment beams and to compare with that of a conventional kV-CBCT acquisition. Methods: kV imaging system integrated into Varian TrueBeam accelerators was modeled using EGSnrc Monte Carlo user code, BEAMnrc and DOSXYZnrc code was used in dose calculations. The simulated realistic kV beams from the Varian TrueBeam OBI 1.5 system were used to calculate dose to patient based on CT images. Organ doses were analyzed using DVHs. The imaging dose to patient resulting from realistic multiple tomosynthesis acquisitions with each 25–30 degree kV source rotation between 6 treatment beam gantry angles was studied. Results: For a typical lung SBRT treatment delivery much lower (20–50%) kV imaging doses from the sum of realistic six tomosynthesis acquisitions with each 25–30 degree x-ray source rotation between six treatment beam gantry angles were observed compared to that from a single CBCT image acquisition. Conclusion: This work indicates that the kV imaging in this proposed Limited-angle Intra-fractional Verification (LIVE) System for SBRT Treatments has a negligible imaging dose increase. It is worth to note that the MV imaging dose caused by MV projection acquisition in-between static beams in LIVE can be minimized by restricting the imaging to the target region and reducing the number of projections acquired. For arc treatments, MV imaging acquisition in LIVE does not add additional imaging dose as the MV images are acquired from treatment beams directly during the treatment.

60 APPLIED LIFE SCIENCES↗

SU-F-BRA-06: Dose Distributions for the CivaSheet Pd-103 Directional Brachytherapy Device

Purpose: A flexible polymer membrane (CivaSheet) has been developed by CivaTech Oncology, Inc. (Research Triangle Park, NC) for permanent brachytherapy. Distributed throughout the array are small plastic disks containing Pd-103 and gold foil shielding on one side to provide a directional dose distribution and facilitate imaging. This study evaluated dosimetry for the CivaSheet. Methods: Manufacturer-provided dimensional and compositional information for the device were compared to physical samples for validation of design information, then entered into the MCNP6 radiation transport code for dosimetry simulations. Three device sizes (6×6, 6×12, or 6×18 disk-arrays) were simulated as the membrane can be custom-sized preceding surgical placement. Dose to water was estimated with 0.01 cm resolution from the surface to 10 cm on both sides of the device. Because this is a novel device with calibration methods under development, results were normalized using DVHs to provide 90% prescription coverage to a plane positioned 0.5 cm from the front surfaces. This same normalization was used for creating isodose distributions. Results: Planar dose distributions of flat CivaSheets were relatively homogeneous with acceptable dose uniformity variations. Differences in the results between the differently sized CivaSheets were not significant. At 0.5 mm, 87% of the target volume was within the therapeutic dose range. Dose hotspots on the CivaSheet forward surfaces were directly above the disks. However, dose hotspots on the rear-facing surfaces were positioned between the disks. Doses in contact with the front surface were similar to those observed for currently available brachytherapy sources. Maximum doses that occurred on the rear surface were approximately 55 times lower than the dose on the front surface. Conclusion: Monte Carlo calculations validated the directional capabilities and advantageous dosimetry of the new Pd-103 brachytherapy device. It appears feasible to re-size the CivaSheet in the operating room with an acceptable variation in prescription dose. Research was supported by CivaTech Oncology, Inc.

60 APPLIED LIFE SCIENCES↗

Radiation-Induced Segregation and Phase Stability in Candidate Alloys for the Advanced Burner Reactor

Major accomplishments of this project were the following: 1) Radiation induced depletion of Cr occurs in alloy D9, in agreement with that observed in austenitic alloys. 2) In F-M alloys, Cr enriches at PAG grain boundaries at low dose (<7 dpa) and at intermediate temperature (400°C) and the magnitude of the enrichment decreases with temperature. 3) Cr enrichment decreases with dose, remaining enriched in alloy T91 up to 10 dpa, but changing to depletion above 3 dpa in HT9 and HCM12A. 4) Cr has a higher diffusivity than Fe by a vacancy mechanism and the corresponding atomic flux of Cr is larger than Fe in the opposite direction to the vacancy flux. 5) Cr concentration at grain boundaries decreases as a result of vacancy transport during electron or proton irradiation, consistent with Inverse Kirkendall models. 6) Inclusion of other point defect sinks into the KLMC simulation of vacancy-mediated diffusion only influences the results in the low temperature, recombination dominated regime, but does not change the conclusion that Cr depletes as a result of vacancy transport to the sink. 7) Cr segregation behavior is independent of Frenkel pair versus cascade production, as simulated for electron versus proton irradiation conditions, for the temperatures investigated. 8) The amount of Cr depletion at a simulated planar boundary with vacancy-mediated diffusion reaches an apparent saturation value by about 1 dpa, with the precise saturation concentration dependent on the ratio of Cr to Fe diffusivity. 9) Cr diffuses faster than Fe by an interstitial transport mechanism, and the corresponding atomic flux of Cr is much larger than Fe in the same direction as the interstitial flux. 10) Observed experimental and computational results show that the radiation induced segregation behavior of Cr is consistent with an Inverse Kirkendall mechanism.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Presentation, Analysis, and Simulation of Active Alignment Strategies for the James Webb Space Telescope

This paper presents three characteristics in the simulated active alignment strategy of the James Webb Space Telescope. The first includes the analysis and comparison of a baseline active alignment strategy with a damped least squares strategy. This baseline utilizes prior knowledge by means of direct human operator interaction to engage sets of telescope compensators to target specific aberration signatures. The baseline is compared to a damped least-squares strategy that utilizes simultaneous engagement of all telescope compensators without explicit human operator inter<actiori to achieve a least-squares telescope compensation. Second, we discuss how the active alignment of the JWST is encapsulated in a linear optical model developed at the Space Telescope Science Institute. This linear optical model provides a framework for an efficient and robust description of the optical control properties of the JWST and clearly articulates the necessity for having a multi-instrument multi-field wavefront sensing strategy to overcome control system non independence and the effects of non-common path errors in the main wavefront sensing camera. Finally. we present analytical results that explicitly map the telescope wavefront responses to the telescope control modes, and we present Monte-Carlo optical performance simulation results that demonstrate the efficacy of the damped least-squares active alignment and the prior-knowledge active alignment schemes.

Upton, Robert S.↗

Alloy Design Workbench-Surface Modeling Package Developed

NASA Glenn Research Center's Computational Materials Group has integrated a graphical user interface with in-house-developed surface modeling capabilities, with the goal of using computationally efficient atomistic simulations to aid the development of advanced aerospace materials, through the modeling of alloy surfaces, surface alloys, and segregation. The software is also ideal for modeling nanomaterials, since surface and interfacial effects can dominate material behavior and properties at this level. Through the combination of an accurate atomistic surface modeling methodology and an efficient computational engine, it is now possible to directly model these types of surface phenomenon and metallic nanostructures without a supercomputer. Fulfilling a High Operating Temperature Propulsion Components (HOTPC) project level-I milestone, a graphical user interface was created for a suite of quantum approximate atomistic materials modeling Fortran programs developed at Glenn. The resulting "Alloy Design Workbench-Surface Modeling Package" (ADW-SMP) is the combination of proven quantum approximate Bozzolo-Ferrante-Smith (BFS) algorithms (refs. 1 and 2) with a productivity-enhancing graphical front end. Written in the portable, platform independent Java programming language, the graphical user interface calls on extensively tested Fortran programs running in the background for the detailed computational tasks. Designed to run on desktop computers, the package has been deployed on PC, Mac, and SGI computer systems. The graphical user interface integrates two modes of computational materials exploration. One mode uses Monte Carlo simulations to determine lowest energy equilibrium configurations. The second approach is an interactive "what if" comparison of atomic configuration energies, designed to provide real-time insight into the underlying drivers of alloying processes.

Abel, Phillip B.↗