SEARCH · Engineering Papers
Results for “Detection and Characterization”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Characterizing 15 Years of Saharan-like, Dry, Well-Mixed Air Layers in North Africa
The Saharan Air Layer (SAL) is a dry, well-mixed layer (WML) of warm and sometimes dusty air of nearly constant water vapor mixing ratio generated by the intense surface heating and strong, dry convection in the Sahara Desert, which has notable downstream impacts on the surface energy balance, organized convective system development, seasonal precipitation, and air quality. Characterizing both WMLs and SALs from the existing rawinsonde network has proven challenging because of its sparseness and inconsistent data reporting. Spurred on by this challenge, we previously created a detection methodology and supporting software to automate the identification and characterization of WMLs from multiple data sources including rawinsondes, remote sensing platforms, and model products. We applied our algorithm to each dataset at both its native and at a common (most coarse data product) vertical resolution to detect WMLs and their characteristics (temperature, mixing ratio, AOD, etc.) at each of the 53 rawinsonde launch sites in north Africa.
Performance of Hamamatsu VUV4 SiPMs for detecting liquid argon scintillation
Detection of light signals is crucial to a wide range of particle detectors. In particular, efficient detection of vacuum ultraviolet (VUV) light will provide new opportunities for some novel detectors currently being developed, but is technically challenging. In this paper, we characterized the performance of Hamamatsu VUV4 silicon photomultipliers (SiPMs) for detecting VUV argon scintillation light without wavelength shifting. Using a customized cryogenic amplifier design, we operated two models of VUV4 SiPMs inside liquid argon and thoroughly examined their direct sensitivities to liquid argon scintillation. In addition to describing their cryogenic performance, we measured a photon detection efficiency of 14.7 +1.1 -2.4 % and 17.2 +1.6 -3.0 % at 128 nm for these two VUV4 models for operation at 4 V of overvoltage, with the main uncertainty arising from the SiPM reflectivity for VUV light.
Development of Ambient Mass Spectrometry Rapid Analysis Methods for Trace Inorganics
Ambient mass spectrometry is being investigated as a new method for rapidly characterizing trace inorganic species, including nuclear materials. SRNL is currently developing electrospray ionization (ESI) and paper spray ionization (PSI) methods for mass spectrometry for the detection of trace inorganic compounds JEOL AccuTOF™-DART ® LP 4G mass spectrometer. Sample analysis generates a complex three-dimensional data set with 10 2 -10 3 individual mass spectra spread temporally. To improve the quality and ease of data extraction from this amount of information, a simple data analysis pipeline written in R/R Studio has been improved and expanded upon. Specifically, the software now has header inputs to set base input/output filenames, isotopes of interest, and a list of concentrations analyzed on the instrument. Using list-based structures to enable batch processing of many concentrations at once, it then loads each file, extracts the relevant intensities for masses of interest from each spectrum, and iterates through each concentration to generate graphs of internal standard & analyte correlations, measured isotope ratios, and total ion chromatograms. It then filters the data to remove points at background levels or at the detector saturation limit. Using this filtered data, the pipeline re-creates the graphs to reveal high-quality information from a low-quality raw dataset. All graphs of the R software then output to PowerPoint format. Additionally, faster 3D visualization functionality was added to the pipeline for viewing the entire data file produced by the instrument as an intensity map. With these data analysis tools ready, samples of strontium nitrate/yttrium nitrate as an analyte/internal standard combination were measured on the AccuTOF. From the filtered data, calibration curves were prepared and limits of detection (LOD) of 1 ppb for ESI-MS and 20 ppb for PSI-MS were obtained. The quality available from the calibration curves and the low limits of detection demonstrate the value of the instrument/analysis pipeline system in characterizing trace inorganics.
Cloud Features Detected by MODIS But Not by CloudSat and CALIOP
The ability to characterize the global cloud cover from space has been greatly enhanced by the availability of MODIS, CloudSat, and CALIOP data. The three sensors provide good complementary information about clouds. In this study, we investigated unexpected observations of certain types of clouds apparent in the MODIS data but not detected by CloudSat and CALIOP. Several examples are presented and generally these undetected clouds are geometrically thin, low-level clouds. In particular, they are located in the Arctic region and have optical thicknesses of less than 14, top height altitudes of below 2.5 km, and layer thickness of less than 1 km. CloudSat may miss such low-level clouds because of its coarse vertical resolution of about 500 m and it has limited sensitivity near the surface. Unexpectedly, CALIOP with a much higher vertical resolution of 30 m also misses these clouds and this is due to the cloud s geometrically thin nature and surface proximity.
IUE observations of two late-type stars Bx Mon (M + pec) and TV Gem (M1 Iab)
The IUE observations of two late type stars BX Mon and TV Gem that reveal the emission properties in the ultraviolet of subluminous companions are discussed. Analysis of the continuum emission observed from BX Mon suggests the companion, is a middle A III star. High excitation emission lines observed between 1200 A and 2000 A that generally do not typify emission observed in either late M type variables or A type stars are also detected. It is suggested that these strong high excitation lines arise in a large volume of gas heated by nonradiation processes that could be the result of tidal interaction and mass exchange in the binary system. In contrast to stars such as BX Mon, the luminous M1 supergiant TV Gem shows unexpected intense UV continuum throughout the sensitivity range of IUE. The UV spectrum of TV Gem is characterized by intense continuum with broad absorption features detected in the short wavelength range. The analysis shows that the companion could be a B9 or A1 III-IV star. Alternate suggestions are presented for explaining the UV continuum in terms of an accretion disk in association with TV Gem.
Characterization of the Hamamatsu VUV4 MPPCs for nEXO
In this paper we report on the characterization of the Hamamatsu VUV4 (S/N: S13370-6152) Vacuum Ultra-Violet (VUV) sensitive Silicon Photo-Multipliers (SiPMs) as part of the development of a solution for the detection of liquid xenon scintillation light for the nEXO experiment. Various SiPM features, such as: dark noise, gain, correlated avalanches, direct crosstalk and Photon Detection Efficiency (PDE) were measured in a dedicated setup at TRIUMF. SiPMs were characterized in the range 163 K = T = 233 K. At an over voltage of 3.1 ± 0.2 V and at T = 163 K we report a number of Correlated Avalanches (CAs) per pulse in the 1µs interval following the trigger pulse of 0.161±0.005. At the same settings the Dark-Noise (DN) rate is 0.137 ± 0.002 Hz/mm2. Both the number of CAs and the DN rate are within nEXO specifications. The PDE of the Hamamatsu VUV4 was measured for two different devices at T = 233 K for a mean wavelength of 189 ± 7 nm. At 3.6 ± 0.2 V and 3.5 ± 0.2 V of over voltage we report a PDE of 13.4 ± 2.6 % and 11 ± 2%, corresponding to a saturation PDE of 14.8 ± 2.8 % and 12.2±2.3%, respectively. Both values are well below the 24 % saturation PDE advertised by Hamamatsu. More generally, the second device tested at 3.5 ± 0.2 V of over voltage is below the nEXO PDE requirement. The first one instead yields a PDE that is marginally close to meeting the nEXO specifications. This suggests that with modest improvements the Hamamatsu VUV4 MPPCs could be considered as an alternative to the FBKLF SiPMs for the final design of the nEXO detector.
Nondestructive characterization of UHMWPE armor materials
Ultra-high molecular weight polyethylene (UHMWPE) is a material increasingly used for fabricating helmet and body armor. In this work, plate specimens consolidated from thin fiber sheets in series 3124 and 3130 were examined with ultrasound, X-ray and terahertz radiation. Ultrasonic through-transmission scans using both air-coupled and immersion modes revealed that the 3130 series material generally had much lower attenuation than the 3124 series, and that certain 3124 plates had extremely high attenuation. Due to the relatively low inspection frequencies used, pulse-echo immersion ultrasonic testing could not detect distinct flaw echoes from the interior. To characterize the nature of the defective condition that was responsible for the high ultrasonic attenuation, terahertz radiation in the time-domain spectroscopy mode were used to image the flaws. Terahertz scan images obtained on the high attenuation samples clearly showed a distribution of a large number of defects, possibly small planar delaminations, throughout the volume of the interior. Their precise nature and morphology are to be verified by optical microscopy of the sectioned surface.
Detection of short-term cropping system-induced changes to soil bacterial communities differs among four molecular characterization methods
Not Available
THE FIRST DETECTION OF BLUE STRAGGLER STARS IN THE MILKY WAY BULGE
We report the first detections of Blue Straggler Stars (BSS) in the bulge of the Milky Way. Proper motions from extensive space-based observations along a single sight line allow us to separate a sufficiently clean and well-characterized bulge sample such that we are able to detect a small population of bulge objects in the region of the color-magnitude diagram commonly occupied by young objects and blue stragglers. Variability measurements of these objects clearly establish that a fraction of them are blue stragglers. Out of the 42 objects found in this region of the color-magnitude diagram, we estimate that at least 18 are genuine BSS. We normalize the BSS population by our estimate of the number of horizontal branch stars in the bulge in order to compare the bulge to other stellar systems. The BSS fraction is clearly discrepant from that found in stellar clusters. The blue straggler population of dwarf spheroidals remains a subject of debate; some authors claim an anticorrelation between the normalized blue straggler fraction and integrated light. If this trend is real, then the bulge may extend it by three orders of magnitude in mass. Conversely, we find that the genuinely young (<5 Gyr) population in the bulge, must be at most 3.4% under the most conservative scenario for the BSS population.
ACCRETION DISK SIGNATURES IN TYPE I X-RAY BURSTS: PROSPECTS FOR FUTURE MISSIONS
Type I X-ray bursts and superbursts from accreting neutron stars illuminate the accretion disk and produce a reflection signal that evolves as the burst fades. Examining the evolution of reflection features in the spectra will provide insight into the burst–disk interaction, a potentially powerful probe of accretion disk physics. At present, reflection has been observed during only two bursts of exceptional duration. We investigate the detectability of reflection signatures with four of the latest well-studied X-ray observatory concepts: Hitomi , Neutron Star Interior Composition Explorer ( NICER ), Athena , and Large Observatory For X-ray Timing ( LOFT ). Burst spectra are modeled for different values for the flux, temperature, and the disk ionization parameter, which are representative for most known bursts and sources. The effective area and throughput of a Hitomi -like telescope are insufficient for characterizing burst reflection features. NICER and Athena will detect reflection signatures in Type I bursts with peak fluxes ≳10{sup 7.5} erg cm{sup 2} s{sup 1} and also effectively constrain the reflection parameters for bright bursts with fluxes of ∼10{sup 7} erg cm{sup 2} s{sup 1} in exposures of several seconds. Thus, these observatories will provide crucial new insight into the interaction of accretion flows and X-ray bursts. For sources with low line-of-sight absorption, the wide bandpass of these instruments allows for the detection of soft X-ray reflection features, which are sensitive to the disk metallicity and density. The large collecting area that is part of the LOFT design would revolutionize the field by tracing the evolution of the accretion geometry in detail throughout short bursts.
Characterization of Structural Vibration and Acoustic Radiation with a Beam-Array Doppler Vibrometer
This paper discusses the operational principles of an assembly of two opto-electronic modules with their configurations based on a Laser-Array Doppler Vibrometer (LADV) and a Shack-Hartmann Wavefront Sensor (SHWFS). Both sensors can operate concurrently providing complementary data. While the SHWFS is a well-established system that enables low-bandwidth spatio-temporal characterization of aerodynamic turbulence, the LADV technology allows real-time detection of structural vibrations and associated acoustic radiation fields. Practical examples are shown of the instruments’ capabilities, focusing on the ability to simultaneously capture, visualize and quantitatively characterize full-field non-stationary structural dynamics and unsteady sound fields or transient flow fields around ground test facility airframe models or other structures of interest. The parallel multi-channel architecture of the LADV system enables synchronous detection and temporal correlation of indicators related to the spatio-temporal vibration of the structure under inspection. This unique feature is essential for real time detection and categorization of the structural and acoustic dynamics of transient events. For the present study, the LADV data have been successfully compared with measurements obtained with the SHWFS in the wake of a subsonic scale-model airfoil. The ability of the LADV-SHWFS coupled measurements to perform real time non-intrusive evaluation and characterization of dynamic processes at operationally relevant bandwidths should provide a deeper insight into the complex structural dynamics that contribute to radiated sound fields.
Performance analysis of a generalized concurrent error detection procedure
A general procedure for error detection in complex systems, called the data block capture and analysis monitoring process, is described and analyzed. It is assumed that, in addition to being exposed to potential external fault sources, a complex system will in general always contain embedded hardware and software fault mechanisms which can cause the system to perform incorrect computations and/or produce incorrect output. Thus, in operation, the system continuously moves back and forth between error and no-error states. These external fault sources or internal fault mechanisms are extremely difficult to detect. The data block capture and analysis monitoring process is concerned with detecting deviations from the normal performance of the system, known as errors, which are symptomatic of fault conditions. The process consists of repeatedly recording a fixed amount of data from a set of predetermined observation lines of the system being monitored (i.e., capturing a block of data) and then analyzing the captured block in an attempt to determine whether the system is functioning correctly. The performances of linear, quadratic, and logarithmic data analysis algorithms are rigorously characterized in terms of the probability of correctly detecting an error, the expectation and variance of the number of false alarms per error, and the expectation and variance of the latency in detection of errors. Insight into the nature of the general problem of error detection is obtained.
Detection of Low Volatility Organic Analytes on Soils Using Infrared Reflection Spectroscopy
Previous work on detection of low-volatility liquid organic (and organophosphorus) analytes on soil indicated strong signal in FTIR spectra in the 2966–2855 cm-1 range attributed to C–H vibrational stretching modes. This range is the focus of detection strategies examined here as an anticipated prelude to subsequent detection and classification approaches utilizing additional spectral bands. This laboratory study is being used to test detection algorithms that may be useful for rapid standoff detection of organics compounds on soil. Six signal processing methods (designed to minimize irrelevant variability in the recorded soil reflection-absorption spectra while enhancing signal from analyte compounds possibly present on soil) were studied. These included Savitzky-Golay second derivatives, extended multiplicative scatter correction (EMSC), and a novel alternative to piece-wise EMSC. The preprocessed signal was then used for detection. Previous work utilized principal components analysis (PCA) based multivariate statistical process control methodologies for detection. Six alternative anomaly detection statistics were examined here that were based on the preprocessed signal, weighted signal, and generalized weighted signal. The latter statistic can be considered easier than PCA with many of the same benefits. Two tests corresponding to different monitoring strategies were examined: test data ‘local’ and ‘non-local’ to the calibration data. Although the results are expected to be optimistic, the generalized weighted approach worked extremely well for the ‘local’ detection test, but was less successful for ‘non-local’ test. Results suggest that good characterization of analyte-free soil prior to monitoring will lead to the best detection performance. Second derivative preprocessing showed the best results on receiver operator characteristic curves and it’s ease of application is a distinct advantage. However, it may not be universally successful for all bands to be considered in the future. Both EMSC and the novel ‘piece-wise’ EMSC methodology showed promise, but some improvements may be necessary.
Final Scientific/Technical Report, Multi-Sensor Inspection and Robotic Systems for Dry Storage Casks
Once removed from service, fuel rod assemblies are cooled in a pool and then placed in dry storage until they can be transported to a repository for disposal. The extended duration that used nuclear fuel spends in dry storage makes it prudent to be able to nondestructively inspect the dry storage casks. The degradation mechanisms of most concern are chloride-induced stress corrosion cracking of the stainless steel canister that confines the spent fuel and distributed cracking of the concrete in the overpack structure. Multi-sensor inspection and robotic systems were researched, developed, built, and tested. One system operates completely outside the cask to inspect the concrete. The other system, known as the PRINSE system, for Proactive Robotic Inspection of Nuclear Storage Enclosures, enters the cask through an outlet vent and navigates around the outer surface of the stainless steel canister. The PRINSE system delivers sensors for: (i) real-time characterization of the canister surface in order to assess whether chlorides are present, (ii) detecting the presence of cracks using shear-horizontal ultrasonic guided waves, (iii) measuring the temperature of the canister surface, and (iv) a gamma radiation counter. The four sensing modalities are applicable to any cask containing a stainless steel canister, however the robotic delivery system is designed specifically for Holtec’s HI-STORM family of casks. Horizontal axis casks have exposed concrete surfaces. A fully contactless air-coupled scanning ultrasonic test platform and a frequency-wavenumber domain data analysis method are used for these concrete structures. Analysis, numerical simulation and experimental results demonstrate that distributed cracks in concrete can be detected and cracked regions localized within a scanned region of concrete. Vertical axis casks (like the HI-STORM family) have steel-clad concrete overpacks. In a separate effort, a semi-coupled test platform and a guided wave attenuation-based data analysis method are used for disbond detection. Analysis, numerical simulation and experimental results show that the bonding conditions of steel-concrete interfaces can be quantitatively characterized using the guided wave signal analysis scheme. The PRINSE system is designed for vertical axis dry storage casks, specifically the HI-STORM family. The double pulse laser-induced breakdown spectroscopy (LIBS) system takes advantage of an optical fiber to deliver intense light to the canister surface that enables surface composition characterization in-situ in real time. Chlorine concentrations as low as 10 mg/m2 were detected on stainless steel. Additionally, a simpler laser setup was created to detect sodium as a surrogate for chlorine, and sodium was detectable when the chlorine concentration was as low as 0.5 mg/m2. The electromagnetic acoustic transducers (EMATs) enable detection of stress corrosion cracks. The EMATs generate shear-horizontal waves that propagate around the canister and are reflected by cracks enabling 100% of the canister weld lines to be inspected. The EMAT-based crack detection system was tested at the Pacific Northwest National Laboratory on a canister containing blind defects and was shown to detect the crack sizes it was designed to detect. The PRINSE system is a novel marsupial robot. The command center and winch outside the cask control the delivery arm and train of cars that traverse the outside of the canister from the cask ventilation system. The sensors are housed in the cargo bays of three cars that comprise the train, which is lowered to the bottom of the canister by the winch. Encoders on the winch enable the sensors to be delivered to a prescribed location, e.g., for re-inspection of a problem area. The PRINSE system does not mar the canister surface, can be extracted manually in the case of a power failure, and is designed for an elevated temperature and gamma radiation environment, although not all components of the prototype are made from the final materials. The PRINSE system was tested on a full canister that was placed inside a HI-STORM cask at the Holtec Manufacturing Division. It was also demonstrated on a full-height mockup at Penn State to a live audience.
Definition of mutually optimum NDI and proof test criteria for 2219 aluminum pressure vessels. Volume 3: Applications to rail defect evaluation
The technique for inspection of railroad rails containing transverse fissure defects was discussed. Both pulse-echo and pitch-catch inspection techniques were used. The pulse-echo technique results suggest that a multiple-scan approach using varying angles of inclination, three-surface scanning, and dual-direction traversing may offer promise of characterization of transverse defects. Because each scan is likely to produce a reflection indicating only a portion of the defect, summing of the individual reflections must be used to obtain a reasonably complete characterization of the defect. The ability of the collimated pitch-catch technique to detect relatively small amounts of flaw growth was shown. The method has a problem in characterizing the portions of the defect near the top surface or web intersection. The work performed was a preliminary evaluation of the prospects for automated mapping of rail flaws.
3D Characterization and Time-Lapse Imaging of the Desiccation Treatability Test at the Hanford BC-Cribs and Trenches Site using High Performance Computing applied to Electrical Resistivity Imaging - 12271
Contaminated vadose zone materials are a potential source of long-term groundwater contamination at many sites across the Department of Energy (DOE) complex. Deep vadose zone contamination presents a particularly challenging remedial problem due to the difficultly of locating contaminants and the expense of access and ex situ treatment. In situ remediation techniques, whereby remedial amendments must be delivered to contaminated soils, have been identified as a potential alternative. However, amendment delivery is typically uncertain and post delivery remedial performance is often not well understood due to limited information available from sparsely spaced boreholes. Recent advancements in electrical resistivity tomography (ERT) are being used to address these challenges at the Hanford site by providing remote, three-dimensional images of contaminant distribution and four-dimensional (three spatial dimensions plus the time dimension) images of in-situ vadose zone remediation processes. These capabilities were recently demonstrated with a large scale surface characterization effort and during a smaller scale desiccation treatability test at the Hanford BC-Cribs area. The results of these efforts demonstrate the utility of leveraging high-performance computing resources to process ERT data for 3D reconnaissance mapping of subsurface contaminants and for detailed 3D monitoring of vadose zone remediation efforts. Two examples of ERT imaging at a former waste disposal facility have been demonstrated at different scales; a large scale reconnaissance survey spanning many hundreds of meters and a detailed monitoring application spanning a few tens of meters. Although ERT is applicable at many scales, resolution is generally governed by proximity to electrodes. For instance, the BCCT reconnaissance survey demonstrated herein lost resolution with depth (i.e. away from surface electrodes), and was unable to detect a high conductivity anomaly at approximately 75 m below ground surface in the cribs area; the deep anomalies were detected during highly focused borehole sampling. Conversely, the desiccation site characterization and monitoring demonstrated high resolution at a small scale, but only because of close proximity to survey electrodes. Although proximity to electrodes is not the only factor governing ERT resolution, it is often the primary factor for determining how an ERT system should be effectively deployed for a given application. Regardless of resolution limitations, the utility of ERT for remotely detecting wastes and monitoring subsurface processes is evident. ERT imaging is not a final detection or monitoring solution alone, but provides a necessary capability to remotely detect subsurface conditions and understand subsurface processes. Such a capability can significantly increase the efficacy and reduce the cost of remediation by guiding sampling efforts and informing remedial system design and operation. However, given the computational demands of 3D ERT characterization and monitoring inversions, the full imaging capability enabled by contemporary ERT survey systems can generally only be realized with high performance computing resources, both hardware and software. (authors)
Analytical ultrasonics for evaluation of composite materials response. Part 2: Generation and detection
To evaluate the response of composite materials, it is imperative that the input excitation as well as the observed output be well characterized. This characterization ideally should be in terms of displacements as a function of time with high spatial resolution. Additionally, the ability to prescribe these features for the excitation is highly desirable. Various methods for generating and detecting ultrasound in advanced composite materials are examined. Characterization and tailoring of input excitation is considered for contact and noncontact, mechanical, and electromechanical devices. Type of response as well as temporal and spatial resolution of detection methods are discussed as well. Results of investigations at Virginia Tech in application of these techniques to characterizing the response of advanced composites are presented.