Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Design Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Oil Production by a Consortium of Oleaginous Microorganisms grown on primary effluent wastewater

Municipal wastewater could be a potential growth medium that has not been considered for cultivating oleaginous microorganisms. This study is designed to determine if a consortium of oleaginous microorganism can successfully compete for carbon and other nutrients with the indigenous microorganisms contained in primary effluent wastewater. RESULTS: The oleaginous consortium inoculated with indigenous microorganisms reached stationary phase within 24 h, reaching a maximum cell concentration of 0.58 g L -1. Water quality post-oleaginous consortium growth reached a maximum chemical oxygen demand (COD) reduction of approximately 81%, supporting the consumption of the glucose within 8 h. The oleaginous consortium increased the amount of oil produced per gram by 13% compared with indigenous microorganisms in raw wastewater. Quantitative polymerase chain reaction (qPCR) results show a substantial population increase in bacteria within the first 24 h when the consortium is inoculated into raw wastewater. This result, along with the fatty acid methyl esters (FAMEs) results, suggests that conditions tested were not sufficient for the oleaginous consortium to compete with the indigenous microorganisms.

Bio-fuel, Municipal wastewater, Oleaginous microor↗

Influence of biotic and abiotic factors on home range size and shape of invasive wild pigs ( Sus scrofa )

Determining factors influencing animal movements at a temporal scale that is similar to that at which management actions are conducted (e.g. weekly) is crucial for identifying efficient methods of wildlife conservation and management. Using global positioning system (GPS) data from 49 wild pigs in the southeast United States, we constructed weekly 50% and 95% utilization distributions to quantify the effects of biotic and abiotic factors on weekly core area and home range size, as well as home range shape. Here we found vegetative composition (i.e. proportion of bottomland hardwoods), season (based on forage availability), meteorological conditions (i.e. temperature and pressure), and sex influenced wild pig weekly home range and core area size, while vegetative composition (i.e. proportion of upland pines) and landscape features (i.e. distance to streams) also were important factors influencing home range shape. At close distances to streams, wild pigs had more elongate home ranges when their home ranges comprised less upland pine habitat; however, farther from streams, there was no change in home range shape across fluctuating proportions of upland pines. These results demonstrate that fine-scale wild pig home ranges and movements are pliable from week to week and influenced by several habitat, landscape, and meteorological attributes that can easily be quantified from available land use and meteorological databases. These findings are important for designing monitoring studies, identifying high risk zones for disease transmission, planning response to disease emergence events, and allowing more effective and efficient short-term management planning.

60 APPLIED LIFE SCIENCES↗

Neutrino oscillation prospects with a dual-baseline beam from BNL to SNOLAB and SURF

The Electron-Ion Collider (EIC) is a next-generation accelerator primarily designed to study the internal structure of nucleons through high-precision electron-hadron collisions. In this work, we explore the feasibility of employing a 1 MW fraction of the EIC proton beam to generate a high-intensity GeV-scale neutrino beam for long-baseline oscillation studies. We have simulated proton-target interactions and optimize the resulting neutrino fluxes for water-based liquid scintillator (WbLS) detectors located at distinct baselines of 900 km and at 2900 km. Oscillation analyses performed with GLoBES show that extended baselines allow access to multiple oscillation maxima, significantly enhancing sensitivity to leptonic CP violation. The study also examines the interplay between matter effects and the intrinsic CP violating phase in shaping observable asymmetries. We note that simplified systematics and no backgrounds are used in this analysis to establish the baseline physics potential. These results suggest that the EIC proton beam could provide a novel and complementary source for precision neutrino physics, extending the scientific reach of the EIC program.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design, synthesis and molecular docking studies of quinazolin-4-ones linked to 1,2,3-triazol hybrids as Mycobacterium tuberculosis H{sub 37}Rv inhibitors besides antimicrobial activity

Quinazolin-4-ones linked to 1,2,3-triazol (10) were identified as inhibitors of the bisphosphonate BPH-700 transcriptional factor from a high throughput screen. A series of 1,4-disubstituted triazoles (10a–j) were synthesized by the Cu-catalyzed azide-alkyne cyclo addition of 5-methoxy-2-nitro-4-(prop-2-yn-1-yloxy) benzamide (6) with various substituted azido benzenes (7) in the presence of CuSO{sub 4} under aerobic conditions followed by click reaction with substituted aldehydes. The target compounds were screened for antitubercular activity against Mycobacterium tuberculosis H{sub 37}Rv by Broth micro dilution method using Lowenstein Jensen medium (LJ) (MIC < 9 μg/mL). Majority of the compounds 10b, 10d, 10e, 10i and 10j displayed good antitubercular activity with MIC 7–11 μg/mL. Further, 10e exhibited a promising inhibition with MIC 7 μg/mL, compared to the reference drug Rifampicin. Docking studies have been performed to understand the interactions between the synthesized compounds and the active site of pantothenate synthetase Mycobacterium tuberculosis H{sub 37}Rv organism. The study revealed that the target compounds showed good affinity toward the protein when compared to the standard drug Pefloxacin. Further, 10b was found to interact with three amino acids, viz., Gln92, Arg200, Ser196, as evidenced by the large interaction energy (ΔG = −8.16 kcal/mol). Besides the above, the synthesized quinazolinone triazoles 10a–j were evaluated for their antibacterial activities against a panel of Gram +ve and Gram –ve bacteria. Among them 10a, 10e, 10 h and 10j showed promising broad spectrum antibacterial activity with inhibition in the range of 19–33-mm diameter of inhibition zone (DIZ).

60 APPLIED LIFE SCIENCES↗

Anticancer activities of novel Mannich bases against prostate cancer cells

This study was designed to synthesize hybridizing molecules starting from compound of 6-(4-phenyl-piperazin-1-yl)pyridine-3-ylamine by enhancing its biological activity with other heterocycles and to determine anticancer activity of the resulting compounds. To this end, 6-(4-phenylpiperazin-1-yl)pyridin-3-ylamine (4) was used as the leading compound, which is known to exert anticancer activities. The synthesis of the leading compound was carried out using 1-(5-nitropyridin-2-yl)-4-phenylpiperazine (3) which was obtained by a novel method with the reaction of N-phenylpiperazine (2) and 2-chloro-5-nitropyridine. 6-(4-phenylpiperazin-1-yl)pyridin-3-ylamine (4) was converted to compound 5, an active intermediate compound, by substitution of one of the amine hydrogens with ethyl bromoacetate. The resulting ester product (5) followed by the hydrazidation (6) was added arylisocyanate to obtain the active intermediate (8). Then, by a series of substitution through cyclization and condensation reactions, thiazolidinone (9), 1,3,4-oxadiazole (7), and 1,2,4-triazole (10) were synthesized. Novel Mannich bases (11a–11f and 12a–12f) were obtained using oxazole (7) and triazole (10) hetero rings with primer or secondary amine compounds. The characterization of the compounds was completed using FT IR, {sup 1}H-NMR, {sup 13}C-NMR, HRMS spectroscopic methods and elemental analysis technique. The chemicals, then, were tested for their anticancer activities against prostate cancer cell lines PC3 [ATCC, CRL-1435], LNCaP [ATCC, CRL-1740], and DU145 [ATCC, HTB-81]. The results revealed that the Mannich bases exhibited moderate cytotoxic activity against cancer cells tested.

60 APPLIED LIFE SCIENCES↗

Experimental Study of Poly-l-Lactic Acid Biodegradable Stents in Normal Canine Bile Ducts

Purpose: This study was designed to clarify the advantages of biodegradable stents in terms of mucosal reaction and biodegradation after placement. We designed a biodegradable stent and assessed stent degradation and changes in the normal bile ducts of dogs. Methods: The biodegradable stent is a balloon-expandable Z stent consisting of poly-l-lactic acid (PLLA) with a diameter of 6 mm and a length of 15 mm. We assessed four groups of three beagle dogs each at 1, 3, 6, and 9 months of follow-up. After evaluating stent migration by radiography and stent and bile duct patency by cholangiography, the dogs were sacrificed to remove the bile duct together with the stent. The bile duct lumen was examined macroscopically and histologically, and the stent degradation was examined macroscopically and by scanning electron microscopy (SEM). Results: Bile duct obstruction was absent and none of the stents migrated. Macroscopic evaluation showed moderate endothelial proliferation in the bile ducts at the implant sites at 3 and 6 months and a slight change at 9 months. Slight mononuclear cell infiltration was histologically identified at all time points and epithelial hyperplasia that was moderate at 3 months was reduced to slight at 6 and 9 months. Stent degradation was macroscopically evident in all animals at 9 months and was proven by SEM in two dogs at 6 months and in all of them at 9 months. Conclusions: Our results suggest that PLLA bioabsorbable stents seems to be useful for implantation in the biliary system with further investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Enhanced Ablation of High Intensity Focused Ultrasound with Microbubbles: An Experimental Study on Rabbit Hepatic VX2 Tumors

Purpose: This study was designed to assess the enhanced effect of high intensity focused ultrasound (HIFU) ablation with microbubbles on rabbit hepatic VX2 tumors and to compare the detection sensitivity of CEUS and CECT to determine the residual viable tissue after ablation of HIFU. Methods: Forty rabbits with hepatic VX2 tumors were randomly separated into two groups (20 animals per group) before HIFU ablation. A bolus of 0.2 mL of saline or a microbubble-based ultrasound (US) contrast agent was injected intravenously to group I rabbits and group II rabbits, respectively. The HIFU ablation procedure was started 15 s after the injection. Tumors were examined with grayscale contrast-enhanced ultrasound (CEUS) and contrast-enhanced computed tomography (CECT) immediately before and after HIFU ablation. Histopathologic assessment was performed immediately after treatment imaging. Results: Before ablation, intense contrast enhancement during arterial phase was observed at the whole tumors or the periphery of the tumors by CEUS and CECT. Lower HIFU energy was used in group II than in group I (P < 0.001). Histopathologic assessment revealed local residual viable tumor tissues due to incomplete ablation in 47.4% (9/19) of tumors in group I and 10% (2/20) of tumors in group II (P < 0.05). The concordance rate of CEUS (90.9%) with histopathology on residual tumor detection was higher than that of CECT (27.3%, P < 0.05). Conclusions: Introduction of the microbubble agent enhances HIFU therapeutic efficacy. CEUS proves to have high sensitivity in assessment of residual viable rabbit VX2 tumor after HIFU.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Covered Biodegradable Stent: New Therapeutic Option for the Management of Esophageal Perforation or Anastomotic Leak

Purpose: This study was designed to evaluate our experience with the treatment of postoperative anastomotic leaks and benign esophageal perforations with covered biodegradable stents. Materials and Methods: From 2008 to 2010, we treated five men with either an anastomotic leak or benign esophageal perforation by implanting of covered biodegradable Ella-BD stents. The average age of the patients was 60 (range, 38-74) years. Postoperative anastomotic leaks were treated in four patients (1 after esophagectomy, 1 after resection of diverticulum, 2 after gastrectomy). In one patient, perforation occurred as a complication of the treatment of an esophageal rupture (which occurred during a balloon dilatation of benign stenosis) with a metallic stent. Results: Seven covered biodegradable stents were implanted in five patients. Primary technical success was 100%. Clinical success (leak sealing) was achieved in four of the five patients (80%). Stent migration occurred in three patients. In two of these patients, the leak had been sealed by the time of stent migration, therefore no reintervention was necessary. In one patient an additional stent had to be implanted. Conclusion: The use of biodegradable covered stents for the treatment of anastomotic leaks or esophageal perforations is technically feasible and safe. The initial results are promising; however, larger number of patients will be required to evaluate the capability of these biodegradable stents in the future. The use of biodegradable material for coverage of the stent is essential.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Transluminal Angioplasty of Hepatic Artery Stenosis in Patients After Orthotopic Liver Transplantation: Mid-term Results

Purpose: This study was designed to present our experience with percutaneous treatment of hepatic artery stenosis in orthotopic liver transplant patients and to evaluate the efficacy, technical outcomes, and mid-term clinical results of the procedure. Methods: Twenty-two percutaneous transluminal angioplasties (PTAs) were performed in 19 liver transplant recipients at our institution between 1998 and 2010. Stents were placed into the hepatic/celiac artery in 16 PTAs, but balloon dilatation alone was performed in 6 because of the anatomical condition of the vessel. PTA/stenting was indicated in 17 patients because of elevated liver enzymes; 2 patients were asymptomatic. The objective of treating stenosis was prevention of long-term complications, including thrombosis. Results: Technical success was achieved in all patients. There was only one complication: dissection of the treated artery without any subsequent adverse effects. In all patients, elevated liver enzyme levels improved after treatment. No restenosis was observed in any patient during a mean follow-up of 2.6 years (1 month to 5.5 years). Conclusions: Percutaneous angioplasty/stent placement is a safe method for the treatment of hepatic artery stenosis after orthotopic liver transplantation, with a high technical success rate and promising mid-term results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Role of 'Cutting' Balloon Angioplasty for the Treatment of Short Femoral Bifurcation Steno-Obstructive Disease

This study was designed to report our experience with 'cutting' balloon angioplasty (CBA) for the treatment of short femoral bifurcation arterial stenosis. Between March 2005 and September 2007, 18 consecutive patients who were high-risk for surgery with critical limb ischemia or severe lifestyle-limiting claudication underwent 'cutting' balloon angioplasty (4-6 mm diameter/15-20-mm length) for the treatment of 27 focal (<3 cm) severe fibro-calcified stenosis of the common femoral artery (n = 14) and/or the proximal part of the superficial femoral artery (n = 6) or profunda femoris (n = 7). Baseline patient demographic data, pre- and post-procedural patient clinical data, and procedural results were recorded. Follow-up consisted of clinical check-up and color duplex ultrasonography (CDU) examination 1, 3, 6, 12, and 18 months after the procedure. All endovascular treatments were successfully performed with clinical success obtained for all patients. No complications occurred during all treatments and no patient required surgical conversion or placement of a stent because of recoil, dissection, or arterial tears. No acute vessel closure was registered. During a mean follow-up of 9.4 (range, 6-18) months, endovascular treatment (CBA) was performed for restenosis/occlusion of seven lesions (25.9%) in four patients, whereas surgical treatment (endarterectomy with patch) for restenosis/occlusion of three lesions (11.1%) was performed in two patients with a consequent reintervention rate of 37%. Primary and secondary patency rates were 84.6 and 88.4% at 6 months and 57.9 and 79.6% at 12 months, respectively. No major limb amputation was performed, with a 12-month limb salvage rate of 88.9%. CBA seems to be a valuable tool for the endovascular treatment of focal femoral bifurcation stenotic lesions for patients who are poor candidates for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Endovascular Thrombolysis Using Monteplase for Non-chronic Deep Venous Thrombosis

This study was designed to evaluate the usefulness of endovascular thrombolysis using monteplase for deep venous thrombosis (DVT). Between December 2005 and October 2009, at our institution nine endovascular thrombolysis treatments with monteplase were performed for symptomatic DVT in eight patients (6 women, 2 men; mean age, 56 (range, 15-80) years). In all, systemic anticoagulation administered by the peripheral intravenous route with heparin and/or thrombolysis with urokinase followed by anticoagulation with orally administered warfarin had been performed, and subsequently six endovascular treatments without monteplase were administered. However, DVT persisted, and endovascular treatments with monteplase were tried. In six (67%) of the nine procedures, DVT completely or almost completely disappeared after endovascular thrombolysis with monteplase. Mean dose of monteplase used was 2,170,000 IU. There was only one procedure-related complication. In one patient, just after thrombolysis with monteplase, bleeding at the puncture site and gingival bleeding occurred. Bleeding was stopped by manual astriction only. Endovascular thrombolysis with monteplase may be an effective treatment for DVT, even in cases resistant to traditional systemic anticoagulation and thrombolysis and endovascular procedures without monteplase.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New Technique for the Preservation of the Left Common Carotid Artery in Zone 2a Endovascular Repair of Thoracic Aortic Aneurysm

To describe a technique for the preservation of the left common carotid artery (CCA) in zone 2 endovascular repair of thoracic aortic aneurysm. This technique involves the placement of a guide wire into the left CCA via the right brachial artery before stent graft deployment to enable precise visualization and protection of the left CCA during the whole procedure. Of the 107 patients with thoracic endovascular aortic repair in our study, 32 (30%) had the left subclavian artery intentionally covered (landing zone 2). Eight (25%) of those 32 had landing zone 2a-the segment distally the origin of the left CCA, halfway between the origin of the left CCA and the left subclavian artery. In all patients, a guide wire was positioned into the left CCA via the right brachial artery before stent graft deployment. It is a retrospective study in design. In seven patients, stent grafts were positioned precisely. In the remaining patient, the positioning was imprecise; the origin of the left CCA was partially covered by the graft. A stent was implanted into the left CCA to restore the flow into the vessel. All procedures were performed successfully. The technique of placing a guide wire into the left CCA via the right brachial artery before stent graft deployment is a safe and effective method that enables the precise visualization of the left CCA during the whole procedure. Moreover, in case of inadvertent complete or partial coverage of the origin of the left CCA, it supplies safe and quick access to the artery for stent implantation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of Hemostatic Durability between N-Butyl Cyanoacrylate and Gelatin Sponge Particles in Transcatheter Arterial Embolization for Acute Arterial Hemorrhage in a Coagulopathic Condition in a Swine Model

This study was designed to compare the efficacy of transcatheter arterial embolization (TAE) with N-butyl cyanoacrylate (NBCA) or gelatin sponge particles (GSP) for acute arterial bleeding in a coagulopathic condition using a swine model. Four healthy swine were divided into two coagulopathic conditions: mild and severe. Five hemorrhages were created in each swine (10 hemorrhages per coagulopathy). Mild coagulopathy was achieved by bloodletting 10% of the total circulatory whole blood and preserving activated clotting time (ACT) less than 200 s (ACT < 200 s state); severe coagulopathy was achieved by bloodletting 30% and preserving ACT > 400 s (ACT > 400-second state). For each state, of ACT < 200 s or ACT > 400 s, TAE was conducted with GSP or NBCA to control five hemorrhages arising from artificially created renal and splenic injuries. Angiography immediately after TAE with GSP or NBCA showed complete occlusion in both coagulopathic conditions. In the ACT < 200-second state, follow-up angiography at 5-30 min after TAE with GSP or NBCA showed no evidence of recurrent hemorrhage. In the ACT > 400-second state, follow-up angiography showed recurrent hemorrhage in four (80%) of the five hemorrhages embolized with GSP and in one (20%) of the five hemorrhages embolized with NBCA. Microscopically, red thrombi were observed densely surrounding GSP in mild coagulopathy but were scarce in severe coagulopathy. In a condition with severe coagulopathy, TAE with NBCA was more effective in durability to cease active arterial bleeding than with GSP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Ischemic Effects of Transcatheter Arterial Embolization with N-Butyl Cyanoacrylate-Lipiodol on the Colon in a Swine Model

This study was designed to assess the safety of transcatheter arterial embolization (TAE) with n-butyl cyanoacrylate-lipiodol (NBCA-Lp) for the large bowel and to investigate the vital response to NBCA-Lp in a swine model. In nine swine, nine arteries nourishing the colon were embolized with NBCA-Lp (1 ml of NBCA mixed with 4 ml of lipiodol): sigmoid-rectal branch artery in six swine, right colic branch artery in two, and middle colic branch artery in one. The amount of NBCA-Lp was 0.1-0.4 ml. Sacrifice was conducted 3 days after TAE to identify histological infarction. Classification was conducted retrospectively: group A, vasa recta without NBCA-Lp embolization despite TAE; group B, three or fewer vasa recta with NBCA-Lp embolization; and group C, five or more vasa recta with NBCA-Lp embolization. In one swine in group A, no necrotic focus was observed. In group B, three of four swine experienced no ischemic damage. The remaining one swine experienced necrosis of mucosal and submucosal layers in one-fourth of the circumference. In group C, all four swine with marginal artery and five vasa recta or more embolized experienced total necrosis of mucosa, submucosa, and smooth muscle layers of the whole colonic circumference. Significant difference on the extent of ischemic damage was observed between groups B and C (P < 0.05). Microscopically, NBCA-Lp induced acute vasculitis. Embolization of three or fewer vasa recta with NBCA-Lp induced no ischemic damage or limited necrosis, whereas embolization of five or more vasa recta with NBCA-Lp induced extensive necrosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Thermal Ablation of Lung Tissue: In Vivo Experimental Comparison of Microwave and Radiofrequency

This study was designed to compare feasibility, safety, and effectiveness of microwave (MW) ablation versus radiofrequency (RF) ablation of lung tissue in a rabbit model. Twenty New Zealand White rabbits were submitted to MW (n = 10, group A) or RF ablation (n = 10, group B). The procedures were performed with a prototype MW ablation device with a 1.6-cm radiating section antenna (Valleylab MW Ablation System) and with a 2-cm exposed-tip RF electrode (Cool-tip RF Ablation System). At immediate computed tomography increase in density, maximum diameters (D1-D3) of ablation zones were measured and ablation volume was calculated. Histopathologic assessment was performed 3 and 7 days after the procedure. Technical success was achieved in nine of 10 rabbits in each group. One death occurred in group B. Complications included pneumothorax (group A, n = 4; group B, n = 4), abscess (group A, n = 1; group B, n = 1), and thoracic wall burn (group A, n = 4). No significant differences were demonstrated in attenuation increase (P = 0.73), dimensions (P = 0.28, 0.86, 0.06, respectively, comparing D1-D3) and volume (P = 0.17). At histopathology, ablation zones were similar, with septal necrosis, edema, hemorrhage, and peripheral lymphocytic infiltrate. Complete thrombosis of more than 90% of vessels up to 2 mm in diameter was depicted at the periphery of the ablation zone in group A specimens. In group B specimens, complete thrombosis was depicted in 20% of vessels. Feasibility and safety of MW and RF ablation are similar in a lung rabbit model. MW ablation produces a greater damage to peripheral small vessels inducing thrombosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Massive Pulmonary Embolism: Treatment with the Rotarex Thrombectomy System

This study was designed to evaluate the efficacy and safety of percutaneous mechanical thrombectomy (PMT) for acute massive pulmonary embolism (PE). Fourteen patients (8 men, 6 women) with a mean age of 55.4 (range, 38-71) years with acute massive PE were initially diagnosed by computed tomography (CT) and confirmed by pulmonary angiography. All patients presented with acute PE symptoms and hemodynamic compromise. Each patient was treated with Straub Rotarex thrombectomy device and five patients received additional thrombolysis. Technique success and clinical improvement were achieved in all patients without major complications. The mean pulmonary artery pressure (PAP) decreased from 37.6 {+-} 6.6 to 29 {+-} 6.4 mmHg (P < 0.01) after PMT. Partial arterial pressures of O{sub 2} (PaO{sub 2}) increased from 61.1 {+-} 9.2 to 88 {+-} 5.1 mmHg (P < 0.01). The Miller index was 0.67 {+-} 0.11 and 0.37 {+-} 0.13 (P < 0.01), respectively, before and after PMT (P < 0.01). Eleven patients had no recurrence of PE on a mean follow-up of 28.3 months, whereas the other three patients were lost to follow-up. The preliminary experience in our series suggests that the Straub Rotarex thrombectomy device, which has been utilized in peripheral arteries, also is useful for the treatment of acute massive PE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Intercostal Artery Supplying Hepatocellular Carcinoma: Demonstration of a Tumor Feeder by C-arm CT and Multidetector Row CT

This study was designed to describe tumor feeders from the intercostal artery supplying hepatocellular carcinoma (HCC) on C-arm CT and multidetector row CT. From March 2008 to May 2009, C-arm CT of the intercostal artery was prospectively performed in 24 HCC patients. Two interventional radiologists, who performed C-arm CT, evaluated tumor feeders on C-arm CT and multidetector row CT scans by consensus. In total, 35 intercostal arteries were examined by C-arm CT. All tumor feeders except one showed a sharp upward turn at or near the costochondral junction. On axial C-arm CT images, all tumor feeders were observed as an enhancing dot in the upper intercostal space along the diaphragm. On multidetector CT scans, 17 tumor feeders were observed and 18 were not. Tumor feeders from the intercostal artery are observed as an enhancing dot along the diaphragm on C-arm CT and can be seen on multidetector row CT in approximately half of patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of BMSs with SES for Symptomatic Intracranial Disease of the Middle Cerebral Artery Stenosis

This study was designed to compare the clinical and angiographic outcomes of patients with symptomatic atherosclerotic middle cerebral artery stenosis treated with balloon-mounted stents (BMS) and self-expandable Wingspan system (SES). We reviewed the 69 consecutive stent placement procedures for symptomatic atherosclerotic stenosis ({>=}70) in M1 segment of middle cerebral artery in 67 patients in 3 years. According to the stent types, the patients were classed as BMS and SES groups. The demographic characteristics, conventional risk factors of ischemic stroke, degree of stenosis, periprocedural complications, stent types, and clinical and angiographic outcomes were analyzed. There were 39 patients in the BMS group and 28 patients in the SES group. The demographic characteristics, conventional risk factors, and periprocedural complications were similar but different in residual stenosis after stenting in both groups (5.9% {+-} 9.9% vs. 14.4% {+-} 14.6%; P = 0.01). For the overall cohort, the rate of stroke or death and restenosis was 10.9% (7/66) and 24.5% (14/57), respectively. The frequency of restenosis was higher in the SES group than in the BMS group (log-rank, P = 0.04; crude hazard ratio = 3.03; 95% confidence interval (CI), 1.01-9.15; P = 0.049; and adjusted hazard ratio = 3.61; 95% CI, 1.06-12.27; P = 0.04); however, there was no difference in clinical outcomes (log-rank, P = 0.51; crude hazard ratio = 1.66; 95% CI, 0.36-7.61; P = 0.51; and adjusted hazard ratio = 0.59; 95% CI, 0.04-7.89; P = 0.69). The corrected degree of restenosis was higher in the SES than the BMS group. The prevalence of restenosis was higher in the SES than the BMS group, but the perioperative complications and follow-up clinical outcomes had no significant difference.

62 RADIOLOGY AND NUCLEAR MEDICINE↗