Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Synthesis, structure and properties of Na[AsW{sub 2}O{sub 9}]

Single crystal and polycrystalline powder samples of sodium arseno-tungstate of composition Na[AsW{sub 2}O{sub 9}] were synthesized using high-temperature solid-state methods. The greenish single crystals of the phase were characterized by X-ray diffraction data structure determination and the bulk compound confirmed by powder X-ray data Rietveld refinements. Additionally, scanning electron microscopy (SEM) attached with energy dispersive X-Ray spectroscopy (EDX), thermogravimetry (TG), differential scanning calorimetry (DSC), fourier transform infrared (FTIR) and Raman spectroscopy was performed. A comparative study between Na[AsW{sub 2}O{sub 9}] and isotypic K[AsW{sub 2}O{sub 9}] demonstrates the structural modifications and the consequent properties. Placing sodium in the channel of the arseno-tungstate framework, the average As-O and W-O bond distances did not change due to their rigid-unit like behaviors. However, the unit cell volume contracted about 7.4% caused by shrinkage of the channel dimensions due to shorter Na-O bond distances. The non-linear optical property of the compound has been explained in terms of asymmetric W-O and As-O chemical bonding led by WO{sub 6} and AsO{sub 4} polyhedral distortion, respectively.

36 MATERIALS SCIENCE↗

Hierarchically MoS2 nanospheres assembled from nanosheets for superior CO gas-sensing properties

Highlights: • Preparation of 3D Hierarchical large surface area MoS{sub 2} nanospheres from nansheets. • The efficient enhanced gas-sensing response of 92.6 at 500 ppm for CO at 230 °C. • Higher selectivity towards CO than other gases at different temperature ranges. - Abstract: Hierarchical three dimensional MoS{sub 2}nanostructures composed of small sheet-like nanostructures are successfully prepared using a simple two-step hydrothermal process with sodium dodecyl sulfate (SDS), as a surface modifier. The as-preparedMoS{sub 2}nanospheres are characterized by XRD, BET, XPS, EDS, SEM and HRTEM. The gas–sensing properties of as–prepared MoS{sub 2}nanostructures are tested at 175–230 °C temperatures for 50–500 ppm concentration range, using an efficient ceramic-tube sensor system via an intelligent gas testing system. A high response and selectivity towards carbon monoxide than other gases is observed. Comparative studies of MoS{sub 2}nanostructures for different concentration of carbon monoxide gas and definite sensor-stability for different gases are studied, as well. The sensor fabrication and sensing mechanism is discussed as well.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Effect of static local distortions vs. dynamic motions on the stability and band gaps of cubic oxide and halide perovskites

Ternary ABX 3 perovskites made of corner-sharing BX 6 octahedra have long featured prominently in solid-state chemistry and condensed matter physics. Still, the joint understanding of their two main subgroups—halides and oxides—has not been fully developed. Indeed, unlike the case in simpler compounds having a single, robust repeated motif (“monomorphous”), certain cubic perovskites can manifest a non-thermal (= intrinsic) distribution of local motifs (“polymorphous networks”). Such static deformations can include positional degrees of freedom (e.g., atomic displacements and octahedral tilting) or magnetic moment degrees of freedom in paramagnets. Unlike thermal motion, such static distortions do not time-average to zero, being an expression of the intrinsic symmetry breaking preference of the chemical bonding. Here, the present study compares electronic structure features of oxide and halide perovskites starting from the static polymorphous distribution of motifs described by Density Functional Theory (DFT) minimization of the internal energy, continuing to finite temperature thermal disorder modeled via finite temperature DFT molecular dynamics. We find that (i) different oxide vs. halide ABX 3 compounds adopt different energy-lowering symmetry-breaking modes. The calculated pair distribution function (PDF) of SrTiO 3 from the first-principles agrees with recently measured PDF. (ii) In both oxides and halides, such static distortions lead to band gap blueshifts with respect to undistorted cubic Pm-3m structure. (iii) For oxide perovskites, high-temperature molecular dynamics simulations initiated from the statically distorted polymorphous structures reveal that the thermally-induced distortions can lead to a band gap redshift. (iv) In contrast, for cubic halide perovskite CsPbI 3 , both the intrinsic distortions and the thermal distortions contribute in tandem to band gap blueshift, the former, intrinsic effect being dominant. (v) In the oxide SrTiO 3 and CaTiO 3 (but not in halide) perovskites, octahedral tilting leads to the emergence of a distinct Γ–Γ direct band gap component as a secondary valley minimum to the well-known indirect R–Γ gap. Understanding such intrinsic vs. thermal effects on oxide vs. halide perovskites holds the potential for designing target electronic properties.

36 MATERIALS SCIENCE↗

Optimization of Stereotactic Radiotherapy Treatment Delivery Technique for Base-Of-Skull Meningiomas

This study compares static conformal field (CF), intensity modulated radiotherapy (IMRT), and dynamic arcs (DA) for the stereotactic radiotherapy of base-of-skull meningiomas. Twenty-one cases of base-of-skull meningioma (median planning target volume [PTV] = 21.3 cm{sup 3}) previously treated with stereotactic radiotherapy were replanned with each technique. The plans were compared for Radiation Therapy Oncology Group conformity index (CI) and homogeneity index (HI), and doses to normal structures at 6 dose values from 50.4 Gy to 5.6 Gy. The mean CI was 1.75 (CF), 1.75 (DA), and 1.66 (IMRT) (p < 0.05 when comparing IMRT to either CF or DA plans). The CI (IMRT) was inversely proportional to the size of the PTV (Spearman's rho = -0.53, p = 0.01) and at PTV sizes above 25 cm{sup 3}, the CI (IMRT) was always superior to CI (DA) and CI (CF). At PTV sizes below 25 cm{sup 3}, there was no significant difference in CI between each technique. There was no significant difference in HI between plans. The total volume of normal tissue receiving 50.4, 44.8, and 5.6 Gy was significantly lower when comparing IMRT to CF and DA plans (p < 0.05). There was significantly improved dose sparing for the brain stem and ipsilateral temporal lobe with IMRT but no significant difference for the optic chiasm or pituitary gland. These results demonstrate that stereotactic IMRT should be considered to treat base-of-skull meningiomas with a PTV larger than 25 cm{sup 3}, due to improved conformity and normal tissue sparing, in particular for the brain stem and ipsilateral temporal lobe.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dosimetric and Radiobiologic Comparison of 3D Conformal Versus Intensity Modulated Planning Techniques for Prostate Bed Radiotherapy

Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Helical Tomotherapy of Nasopharyngeal Carcinoma-Any Advantages Over Conventional Intensity-Modulated Radiotherapy?

Helical tomotherapy uses different planning algorithm and dose delivery method from the linear accelerator (linac)-based intensity-modulated radiotherapy (IMRT). This study compared the dosimetric outcomes between the tomotherapy plans and conventional linac-based IMRT plans in the treatment of nasopharyngeal carcinoma (NPC). Fifteen stage II-III cancer (American Joint Committee on Cancer) NPC patients treated by tomotherapy were conveniently recruited. Apart from the tomotherapy plans, a 7-field 6-MV photon conventional IMRT plan was computed for each patient with the same CT dataset and reference from the dose constraints and target dose prescriptions of the tomotherapy plans using the XiO treatment planning system. Average values of the dose parameters including the conformity index (CI), homogeneity index (HI), maximum and minimum doses of the target volumes, and the maximum and mean doses of the organs at risk (OAR) were compared between the two treatment methods. Better dose coverage of the planning target volume (PTV) was demonstrated in the tomotherapy plans, in which the differences in the maximum and mean doses reached statistical significance (p < 0.05). Besides, the CI of the tomotherapy plans were significantly higher than the conventional linac-based plans for the nasopharynx PTV (NP-PTV) and neck lymphatics PTV (LN-PTV) (p = 0.017 and 0.010, respectively). The HI was significantly smaller in both NP-PTV and LN-PTV (p = 0.024 and < 0.001, respectively). Among the OAR, the brain stem and spinal cord doses in the tomotherapy plans were lower than that of the conventional IMRT plans. However, the doses to the other OAR did not show significant dosimetric differences. In the treatment of nasopharyngeal carcinoma, tomotherapy plans were superior to the 7-field conventional IMRT plans in PTV dose conformity and homogeneity and the sparing of the brain stem and spinal cord. However, no significant advantages were observed for the rest of the OAR.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Novel Method of Island Blocking in Whole Abdominal Radiotherapy Using a Modified Electronic Tissue Compensation Technique

Traditionally, large fields requiring island blocking used external beam radiation therapy (EBRT) with Cerrobend blocks to limit dose to the critical structures. It is laborious to construct blocks and use them on a daily basis. We present a novel technique for island blocking using a modified electronic tissue compensation (MECOMP) technique. Five patients treated at our institution were selected for this study. The study compared two planning techniques: a novel MECOMP and a conventional EBRT technique. Conventional fields were defined using anterior-posterior and posterior-anterior (PA) fields. The kidneys were contoured and an aperture cut-out block was fitted to the OAR with a 1-cm margin (OAR{sub CTV}) and placed in the PA field. A dynamic multileaf collimation (DMLC) plan with ECOMP was developed using identical beam and blocking strategy; this tissue compensation-based fluence map was modified to deliver a 'zero' dose to the CTV{sub OAR} from the PA field. There were no significant differences in the mean, maximum, and minimum doses to the right or left kidney between the two methods. The mean, maximum, and minimum doses to the peritoneal cavity were also not significantly different. The number of monitor units (MUs) required was increased using the MECOMP (273 vs. 1152, p < 0.01). The MECOMP is effectively able to deliver DMLC-based radiotherapy, even with island blocks present. This novel use of MECOMP for whole abdominal radiotherapy should substantially reduce the labor, daily treatment time, and treatment-related errors through the elimination of cerrobend blocks.

61 RADIATION PROTECTION AND DOSIMETRY↗

Intensity-modulated radiosurgery with rapidarc for multiple brain metastases and comparison with static approach

Rotational RapidArc (RA) and static intensity-modulated radiosurgery (IMRS) have been used for brain radiosurgery. This study compares the 2 techniques from beam delivery parameters and dosimetry aspects for multiple brain metastases. Twelve patients with 2-12 brain lesions treated with IMRS were replanned using RA. For each patient, an optimal 2-arc RA plan from several trials was chosen for comparison with IMRS. Homogeneity, conformity, and gradient indexes have been calculated. The mean dose to normal brain and maximal dose to other critical organs were evaluated. It was found that monitor unit (MU) reduction by RA is more pronounced for cases with larger number of brain lesions. The MU-ratio of RA and IMRS is reduced from 104% to 39% when lesions increase from 2 to 12. The dose homogeneities are comparable in both techniques and the conformity and gradient indexes and critical organ doses are higher in RA. Treatment time is greatly reduced by RA in intracranial radiosurgery, because RA uses fewer MUs, fewer beams, and fewer couch angles.

61 RADIATION PROTECTION AND DOSIMETRY↗

RapidArc radiotherapy planning for prostate cancer: Single-arc and double-arc techniques vs. intensity-modulated radiotherapy

RapidArc is a novel technique using arc radiotherapy aiming to achieve intensity-modulated radiotherapy (IMRT)-quality radiotherapy plans with shorter treatment time. This study compared the dosimetric quality and treatment efficiency of single-arc (SA) vs. double-arc (DA) and IMRT in the treatment of prostate cancer. Fourteen patients were included in the analysis. The planning target volume (PTV), which contained the prostate gland and proximal seminal vesicles, received 76 Gy in 38 fractions. Seven-field IMRT, SA, and DA plans were generated for each patient. Dosimetric quality in terms of the minimum PTV dose, PTV hotspot, inhomogeneity, and conformity index; and sparing of rectum, bladder, and femoral heads as measured by V70, V-40, and V20 (% of volume receiving >70 Gy, 40 Gy, and 20 Gy, respectively), treatment efficiency as assessed by monitor units (MU) and treatment time were compared. All plan objectives were met satisfactorily by all techniques. DA achieved the best dosimetric quality with the highest minimum PTV dose, lowest hotspot, and the best homogeneity and conformity. It was also more efficient than IMRT. SA achieved the highest treatment efficiency with the lowest MU and shortest treatment time. The mean treatment time for a 2-Gy fraction was 4.80 min, 2.78 min, and 1.30 min for IMRT, DA, and SA, respectively. However, SA also resulted in the highest rectal dose. DA could improve target volume coverage and reduce treatment time and MU while maintaining equivalent normal tissue sparing when compared with IMRT. SA achieved the greatest treatment efficiency but with the highest rectal dose, which was nonetheless within tolerable limits. For busy units with high patient throughput, SA could be an acceptable option.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effect of beam arrangement on oral cavity dose in external beam radiotherapy of nasopharyngeal carcinoma

This study compared the oral cavity dose between the routine 7-beam intensity-modulated radiotherapy (IMRT) beam arrangement and 2 other 7-beam IMRT with the conventional radiotherapy beam arrangements in the treatment of nasopharyngeal carcinoma (NPC). Ten NPC patients treated by the 7-beam routine IMRT technique (IMRT-7R) between April 2009 and June 2009 were recruited. Using the same computed tomography data, target information, and dose constraints for all the contoured structures, 2 IMRT plans with alternative beam arrangements (IMRT-7M and IMRT-7P) by avoiding the anterior facial beam and 1 conventional radiotherapy plan (CONRT) were computed using the Pinnacle treatment planning system. Dose-volume histograms were generated for the planning target volumes (PTVs) and oral cavity from which the dose parameters and the conformity index of the PTV were recorded for dosimetric comparisons among the plans with different beam arrangements. The dose distributions to the PTVs were similar among the 3 IMRT beam arrangements, whereas the differences were significant between IMRT-7R and CONRT plans. For the oral cavity dose, the 3 IMRT beam arrangements did not show significant difference. Compared with IMRT-7R, CONRT plan showed a significantly lower mean dose, V30 and V-40, whereas the V-60 was significantly higher. The 2 suggested alternative beam arrangements did not significantly reduce the oral cavity dose. The impact of varying the beam angles in IMRT of NPC did not give noticeable effect on the target and oral cavity. Compared with IMRT, the 2-D conventional radiotherapy irradiated a greater high-dose volume in the oral cavity.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comp Plan: A computer program to generate dose and radiobiological metrics from dose-volume histogram files

Treatment planning studies often require the calculation of a large number of dose and radiobiological metrics. To streamline these calculations, a computer program called Comp Plan was developed using MATLAB. Comp Plan calculates common metrics, including equivalent uniform dose, tumor control probability, and normal tissue complication probability from dose-volume histogram data. The dose and radiobiological metrics can be calculated for the original data or for an adjusted fraction size using the linear quadratic model. A homogeneous boost dose can be added to a given structure if desired. The final output is written to an Excel file in a format convenient for further statistical analysis. Comp Plan was verified by independent calculations. A lung treatment planning study comparing 45 plans for 7 structures using up to 6 metrics for each structure was successfully analyzed within approximately 5 minutes with Comp Plan. The code is freely available from the authors on request.

61 RADIATION PROTECTION AND DOSIMETRY↗

A comparison between anisotropic analytical and multigrid superposition dose calculation algorithms in radiotherapy treatment planning

Monte Carlo (MC) simulation is currently the most accurate dose calculation algorithm in radiotherapy planning but requires relatively long processing time. Faster model-based algorithms such as the anisotropic analytical algorithm (AAA) by the Eclipse treatment planning system and multigrid superposition (MGS) by the XiO treatment planning system are 2 commonly used algorithms. This study compared AAA and MGS against MC, as the gold standard, on brain, nasopharynx, lung, and prostate cancer patients. Computed tomography of 6 patients of each cancer type was used. The same hypothetical treatment plan using the same machine and treatment prescription was computed for each case by each planning system using their respective dose calculation algorithm. The doses at reference points including (1) soft tissues only, (2) bones only, (3) air cavities only, (4) soft tissue-bone boundary (Soft/Bone), (5) soft tissue-air boundary (Soft/Air), and (6) bone-air boundary (Bone/Air), were measured and compared using the mean absolute percentage error (MAPE), which was a function of the percentage dose deviations from MC. Besides, the computation time of each treatment plan was recorded and compared. The MAPEs of MGS were significantly lower than AAA in all types of cancers (p<0.001). With regards to body density combinations, the MAPE of AAA ranged from 1.8% (soft tissue) to 4.9% (Bone/Air), whereas that of MGS from 1.6% (air cavities) to 2.9% (Soft/Bone). The MAPEs of MGS (2.6%±2.1) were significantly lower than that of AAA (3.7%±2.5) in all tissue density combinations (p<0.001). The mean computation time of AAA for all treatment plans was significantly lower than that of the MGS (p<0.001). Both AAA and MGS algorithms demonstrated dose deviations of less than 4.0% in most clinical cases and their performance was better in homogeneous tissues than at tissue boundaries. In general, MGS demonstrated relatively smaller dose deviations than AAA but required longer computation time.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the possible benefits of a hybrid VMAT technique in the treatment of non–small cell lung cancer

To assess, using clinical cases, the potential of a hybrid technique for the treatment of non–small cell lung cancer (NSCLC)-blending volumetric-modulated arc therapy (VMAT) and conformal radiation therapy (CRT) fields, and to consider potential issues with implementation of such a technique. Eight clinical cases already treated with CRT were used for a planning study comparing target coverage and organs at risk (OAR) sparing between CRT and hybrid VMAT (VMATh). Quality assurance (QA) implications of the resultant hybrid plans are discussed. The hybrid technique resulted in superior target conformity or improved sparing of OAR or both. The hybrid technique shows promise, but the QA implications of motion at treatment need careful consideration.

61 RADIATION PROTECTION AND DOSIMETRY↗

A dosimetric comparison of 3D-CRT, IMRT, and static tomotherapy with an SIB for large and small breast volumes

Radiation therapy to the breast is a complex task, with many different techniques that can be employed to ensure adequate dose target coverage while minimizing doses to the organs at risk. This study compares the dose planning outcomes of 3 radiation treatment modalities, 3 dimensional conformal radiation therapy (3D-CRT), intensity-modulated radiation therapy (IMRT), and static tomotherapy, for left-sided whole-breast radiation treatment with a simultaneous integrated boost (SIB). Overall, 20 patients with left-sided breast cancer were separated into 2 cohorts, small and large, based on breast volume. Dose plans were produced for each patient using 3D-CRT, IMRT, and static tomotherapy. All patients were prescribed a dose of 45 Gy in 20 fractions to the breast with an SIB of 56 Gy in 20 fractions to the tumor bed and normalized so that D{sub 98%} > 95% of the prescription dose. Dosimetric comparisons were made between the 3 modalities and the interaction of patient size. All 3 modalities offered adequate planning target volume (PTV) coverage with D{sub 98%} > 95% and D{sub 2%} < 107%. Static tomotherapy offered significantly improved (p = 0.006) dose homogeneity to the PTV{sub boost} {sub eval} (0.079 ± 0.011) and breast minus the SIB volume (Breast{sub SIB}) (p < 0.001, 0.15 ± 0.03) compared with the PTV{sub boost} {sub eval} (0.085 ± 0.008, 0.088 ± 0.12) and Breast{sub SIB} (0.22 ± 0.05, 0.23 ± 0.03) for IMRT and 3D-CRT, respectively. Static tomotherapy also offered statistically significant reductions (p < 0.001) in doses to the ipsilateral lung mean dose of 6.79 ± 2.11 Gy compared with 7.75 ± 2.54 Gy and 8.29 ± 2.76 Gy for IMRT and 3D-CRT, respectively, and significantly (p < 0.001) reduced heart doses (mean = 2.83 ± 1.26 Gy) compared to both IMRT and 3D-CRT (mean = 3.70 ± 1.44 Gy and 3.91 ± 1.58 Gy). Static tomotherapy is the dosimetrically superior modality for the whole breast with an SIB compared with IMRT and 3D-CRT. IMRT is superior to 3D-CRT in both PTV dose conformity and reduction of mean doses to the ipsilateral lung.

61 RADIATION PROTECTION AND DOSIMETRY↗

Volumetric-modulated arc radiotherapy for pancreatic malignancies: Dosimetric comparison with sliding-window intensity-modulated radiotherapy and 3-dimensional conformal radiotherapy

Volumetric-modulated arc radiotherapy (VMAT) is an iteration of intensity-modulated radiotherapy (IMRT), both of which deliver highly conformal dose distributions. Studies have shown the superiority of VMAT and IMRT in comparison with 3-dimensional conformal radiotherapy (3D-CRT) in planning target volume (PTV) coverage and organs-at-risk (OARs) sparing. This is the first study examining the benefits of VMAT in pancreatic cancer for doses more than 55.8 Gy. A planning study comparing 3D-CRT, IMRT, and VMAT was performed in 20 patients with pancreatic cancer. Treatments were planned for a 25-fraction delivery of 45 Gy to a large field followed by a reduced-volume 8-fraction external beam boost to 59.4 Gy in total. OARs and PTV doses, conformality index (CI) deviations from 1.0, monitor units (MUs) delivered, and isodose volumes were compared. IMRT and VMAT CI deviations from 1.0 for the large-field and the boost plans were equivalent (large field: 0.032 and 0.046, respectively; boost: 0.042 and 0.037, respectively; p > 0.05 for all comparisons). Both IMRT and VMAT CI deviations from 1.0 were statistically superior to 3D-CRT (large field: 0.217, boost: 0.177; p < 0.05 for all comparisons). VMAT showed reduction of the mean dose to the boost PTV (VMAT: 61.4 Gy, IMRT: 62.4 Gy, and 3D-CRT: 62.3 Gy; p < 0.05). The mean number of MUs per fraction was significantly lower for VMAT for both the large-field and the boost plans. VMAT delivery time was less than 3 minutes compared with 8 minutes for IMRT. Although no statistically significant dose reduction to the OARs was identified when comparing VMAT with IMRT, VMAT showed a reduction in the volumes of the 100% isodose line for the large-field plans. Dose escalation to 59.4 Gy in pancreatic cancer is dosimetrically feasible with shorter treatment times, fewer MUs delivered, and comparable CIs for VMAT when compared with IMRT.

61 RADIATION PROTECTION AND DOSIMETRY↗

A single-gradient junction technique to replace multiple-junction shifts for craniospinal irradiation treatment

Craniospinal irradiation (CSI) requires abutting fields at the cervical spine. Junction shifts are conventionally used to prevent setup error–induced overdosage/underdosage from occurring at the same location. This study compared the dosimetric differences at the cranial-spinal junction between a single-gradient junction technique and conventional multiple-junction shifts and evaluated the effect of setup errors on the dose distributions between both techniques for a treatment course and single fraction. Conventionally, 2 lateral brain fields and a posterior spine field(s) are used for CSI with weekly 1-cm junction shifts. We retrospectively replanned 4 CSI patients using a single-gradient junction between the lateral brain fields and the posterior spine field. The fields were extended to allow a minimum 3-cm field overlap. The dose gradient at the junction was achieved using dose painting and intensity-modulated radiation therapy planning. The effect of positioning setup errors on the dose distributions for both techniques was simulated by applying shifts of ± 3 and 5 mm. The resulting cervical spine doses across the field junction for both techniques were calculated and compared. Dose profiles were obtained for both a single fraction and entire treatment course to include the effects of the conventional weekly junction shifts. Compared with the conventional technique, the gradient-dose technique resulted in higher dose uniformity and conformity to the target volumes, lower organ at risk (OAR) mean and maximum doses, and diminished hot spots from systematic positioning errors over the course of treatment. Single-fraction hot and cold spots were improved for the gradient-dose technique. The single-gradient junction technique provides improved conformity, dose uniformity, diminished hot spots, lower OAR mean and maximum dose, and one plan for the entire treatment course, which reduces the potential human error associated with conventional 4-shifted plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

Micron-pore-sized metallic filter tube membranes for filtration of particulates and water purification

Robust filtering techniques capable of efficiently removing particulates and biological agents from water or air suffer from plugging, poor rejuvenation, low permeance, and high backpressure. Operational characteristics of pressure-driven separations are in part controlled by the membrane pore size, charge of particulates, transmembrane pressure and the requirement for sufficient water flux to overcome fouling. With long term use filters decline in permeance due to filter-cake plugging of pores, fouling, or filter deterioration. Though metallic filter tube development at ORNL has focused almost exclusively on gas separations, a small study examined the applicability of these membranes for tangential filtering of aqueous suspensions of bacterial-sized particles. A mixture of fluorescent polystyrene microspheres ranging in size from 0.5 to 6 {micro}m in diameter simulated microorganisms in filtration studies. Compared to a commercial filter, the ORNL 0.6 {micro}m filter averaged approximately 10-fold greater filtration efficiency of the small particles, several-fold greater permeance after considerable use and it returned to approximately 85% of the initial flow upon backflushing versus 30% for the commercial filter. After filtering several liters of the particle-containing suspension, the ORNL composite filter still exhibited greater than 50% of its initial permeance while the commercial filter had decreased to less than 20%. When considering a greater filtration efficiency, greater permeance per unit mass, greater percentage of rejuvenation upon backflushing (up to 3-fold), and likely greater performance with extended use, the ORNL 0.6 {micro}m filters can potentially outperform the commercial filter by factors of 100-1000 fold.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A comparison of machine learning surrogate models of street-scale flooding in Norfolk, Virginia

Low-lying coastal cities, exemplified by Norfolk, Virginia, face the challenge of street flooding caused by rainfall and tides, which strain transportation and sewer systems and can lead to personal and property damage. While high-fidelity, physics-based simulations provide accurate predictions of urban pluvial flooding, their computational complexity renders them unsuitable for real-time applications. Using data from Norfolk rainfall events between 2016 and 2018, this study compares the performance of a previous surrogate model based on a random forest algorithm with two deep learning models: Long Short-Term Memory (LSTM) and Gated Recurrent Unit (GRU). The comparison of deep learning to the random forest algorithm is motivated by the desire to utilize a machine learning architecture that allows for the future inclusion of common uncertainty quantification techniques and the effective integration of relevant, multi-modal features.

54 ENVIRONMENTAL SCIENCES↗