Impact analysis of heating electrification in US buildings with geothermal heat pumps

Few studies have investigated the impacts of large-scale deployment of geothermal heat pumps (GHPs, also called ground source heat pumps) on the electric grid. GHPs utilize the ground as a heat source to warm buildings more efficiently than other space-heating systems. The coupling with the ground offers seasonal thermal storage so that GHPs can also cool buildings in summer more efficiently than other space-cooling systems. This study simulated the performance of GHP systems for various commercial and residential buildings in 15 climate zones in the United States. Combined with the latest End-Use Load Profiles of the US building stock and grid modeling, this study aims to assess the impacts of a national deployment of GHP systems on the US electric grid in terms of energy consumption, emissions, and operational resilience. The preliminary results show that the GHP deployment can save 429 billion kWh of electricity (a 19% reduction from baseline) and reduce carbon emissions by 496 million tons per year (a 31 % reduction from baseline). A geographical view of the results indicates that retrofitting existing HVAC systems with new GHP systems can lead to further reductions in annual electricity consumption and peak electricity demand in the southern regions of the United States than in other parts of the country. On the other hand, GHP retrofits result in higher percentages of site energy savings and carbon emission reduction in the north (cold climates) than in the south (warm climates).

Liu, Xiaobing↗

Comparative Analysis of ANN and LSTM Prediction Accuracy and Cooling Energy Savings through AHU-DAT Control in an Office Building

This paper proposes the optimal algorithm for controlling the HVAC system in the target building. Previous studies have analyzed pre-selected algorithms without considering the unique data characteristics of the target building, such as location, climate conditions, and HVAC system type. To address this, we compare the accuracy of cooling load prediction using ANN and LSTM algorithms, widely used in building energy research, to determine the optimal algorithm for HVAC control in the target building. We develop a simulation model calibrated with actual data to ensure data reliability and compare the energy consumption of the existing HVAC control method and the two algorithms-based methods. Results show that the ANN algorithm, with a CV(RMSE) of 12.7%, has a higher prediction accuracy than the LSTM algorithm, CV(RMSE) of 17.3%, making it a more suitable algorithm for HVAC control. Furthermore, implementing the ANN-based approach results in a 3.2% cooling energy reduction from the optimal control of Air Handling Unit (AHU) Discharge Air Temperature (DAT) compared to the fixed DAT at 12.8 °C in a representative day. This study demonstrates that ML-based HVAC system control can effectively reduce cooling energy consumption in HVAC systems, providing an effective strategy for energy conservation and improved HVAC system efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Decarbonization of Residential Building Energy Supply: Impact of Cogeneration System Performance on Energy, Environment, and Economics

Electrical and thermal loads of residential buildings present a unique opportunity for onsite power generation, and concomitant thermal energy generation, storage, and utilization, to decrease primary energy consumption and carbon dioxide intensity. This approach also improves resiliency and ability to address peak load burden effectively. Demand response programs and grid-interactive buildings are also essential to meet the energy needs of the 21st century while addressing climate impact. Given the significance of the scale of building energy consumption, this study investigates how cogeneration systems influence the primary energy consumption and carbon footprint in residential buildings. The impact of onsite power generation capacity, its electrical and thermal efficiency, and its cost, on total primary energy consumption, equivalent carbon dioxide emissions, operating expenditure, and, most importantly, thermal and electrical energy balance, is presented. The conditions at which a cogeneration approach loses its advantage as an energy efficient residential resource are identified as a function of electrical grid’s carbon footprint and primary energy efficiency. Compared to a heat pump heating system with a coefficient of performance (COP) of three, a 0.5 kW cogeneration system with 40% electrical efficiency is shown to lose its environmental benefit if the electrical grid’s carbon dioxide intensity falls below 0.4 kg CO 2 per kWh electricity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Modeling Toolkit for Comparing AC and DC Electrical Distribution Efficiency in Buildings

Recently, there has been considerable research interest in the potential for DC distribution systems in buildings instead of the traditional AC distribution systems. Due to the need for performing power conversions between DC and AC electricity, DC distribution may provide electrical efficiency advantages in some systems. To support comparative evaluations of AC-only, DC-only, and hybrid AC/DC distribution systems in buildings, a new modeling toolkit called the Building Electrical Efficiency Analysis Model (BEEAM) was developed and is described in this paper. To account for harmonics in currents or voltages arising from nonlinear devices, the toolkit implements harmonic power flow, along with nonlinear device behavioral descriptions derived from empirical measurements. This paper describes the framework, network equations, device representations, and an implementation of the toolkit in an open source software package, including a component library and graphical interface for creating circuits. Simulations of electrical behavior and device and system efficiencies using the toolkit are compared with experimental measurements of a small office environment in a variety of operating and load configurations. A detailed analysis of uncertainty estimation is also provided. Key findings were that a comparison of predicted versus measured efficiencies and power losses in the validation testbed using the initial toolkit implementation predicted device- and system-level efficiencies with reasonably good accuracy under both balanced and unbalanced AC scenarios. An uncertainty analysis also revealed that the maximum estimated error for system efficiency across all scenarios was 3%, and measured and modeled system efficiency agreed within the experimental uncertainty in approximately half of the scenarios. Based on the correspondence between simulation and measurement, the toolkit is proposed by the authors as a potentially useful tool for comparing efficiency in AC, DC, and hybrid AC/DC distribution systems in buildings.

DC distribution↗

Importance of Window Installation in Residential Building Envelopes Having Continuous External Insulation in Order to Realize Energy Efficiency

Residential buildings are one of the prime candidates in the United States for reducing energy consumption. Continuous exterior insulation (CEI) is being used increasingly often in residential buildings to improve energy efficiency. Windows constitute 15–40% of a building envelope and are the weakest component in energy performance. The installation of windows in walls with CEI has not been well evaluated. We identified four cases of installing windows in walls with CEI of 25–76 mm (1–3 in.) thickness and analyzed the energy loss between the window and wall interface (flanking loss), structural issues, air leakage, and moisture penetration. Thermal analysis showed that the insulation value (RSI) of the 305 mm (12 in.) perimeter wall surrounding a window decreased by 7.6–34.5% in the four cases when compared with the RSI of the wall without the window. A window installation method is proposed to address the issues likely to occur with installation methods currently being used in the field. An out-of-the-box installation system was also designed to achieve a better thermal performance, cost effectiveness, and structural performance in high-performance residential buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Building Stock Models for Embodied Carbon Emissions—A Review of a Nascent Field

Building stock modeling emerges as a critical tool in the strategic reduction of embodied carbon emissions, which is pivotal in reshaping the evolving construction sector. This review provides an overall view of modern methodologies in building stock modeling, homing in on the nuances of embodied carbon analysis in construction. Examining 23 seminal papers, our study delineates two primary modeling paradigms—top-down and bottom-up—each further compartmentalized into five innovative methods. This study points out the challenges of data scarcity and computational demands, advocating for methodological advancements that promise to refine the precision of building stock models. A groundbreaking trend in recent research is the incorporation of machine learning algorithms, which have demonstrated remarkable capacity, improving stock classification accuracy by 25% and urban material quantification by 40%. Furthermore, the application of remote sensing has revolutionized data acquisition, enhancing data richness by a factor of five. This review offers a critical examination of current practices and charts a course toward an environmentally prudent future. It underscores the transformative impact of building stock modeling in driving ecological stewardship in the construction industry, positioning it as a cornerstone in the quest for sustainability and its significant contribution toward the grand vision of an eco-efficient built environment.

Hu, Ming (ORCID:0000000325831161)↗

Improving Building Footprint Extraction Using NAIP and 3DEP Lidar Derived Features with Deep Learning

Accurate building footprint extraction is critical for applications ranging from population estimation to disaster management. Although optical imagery provides detailed spectral information, it often struggles with shadows, occlusions, and background clutter in dense urban environments. Lidar data, by contrast, offer precise elevation and structural attributes but face challenges such as variable point density and noise. This study integrates multispectral imagery from the U.S. Department of Agriculture (USDA) National Agriculture Imagery Program (NAIP) with lidar-derived feature height and intensity from the U.S. Geological Survey (USGS) 3D Elevation Program (3DEP) to improve footprint extraction using a U-Net–based deep learning model. A six-band input stack (RGB, near-infrared, height, intensity) was developed, normalized, and tiled for training and evaluation against Microsoft Global Building Footprints (GBF). Results from the Houston, TX test site show that the six-band model achieved a precision of 0.86, recall of 0.88, F1 score of 0.87, and Intersection-over-Union (IoU) of 0.76, consistently outperforming four-band baselines by reducing false positives while maintaining sensitivity. Predictions on withheld Houston tiles confirmed strong within-region generalization, yielded a precision of 0.78, recall of 0.81, F1 score of 0.79, and IoU of 0.66. Qualitative analysis further revealed limitations stemming from both training label quality and vegetation–building confusion. These findings demonstrate the complementary value of integrating spectral and structural information for robust building footprint extraction and how domain adaptation strategies can be used to enhance cross-regional transferability.

Liu, Jung Kuan [United States Geological Survey (U↗

Exploring Building Retrofit Strategies Using AutoBEM Under Future Weather Scenarios

This study evaluates the long-term effectiveness of energy conservation measures (ECMs) on building energy consumption using AutoBEM, a scalable modeling framework driven by the high-resolution Model America dataset. We simulated 18,951 buildings in Flagstaff, Arizona under four climate scenarios using Future Typical Meteorological Year (fTMY) weather files for six time periods spanning from 1980 to 2099. Six ECMs were analyzed across electricity and gas usage, including HVAC fuel-switching, insulation upgrades, and infiltration control. While some measures, such as reducing space infiltration by percentage, showed minimal or even negative impact on total energy savings at the aggregate level, they proved highly effective for specific building types. Conversely, HVAC electrification offers high gas reduction but shifts demand to electricity, highlighting critical trade-offs under different climate trajectories. Building-type-specific analysis under SSP5-RCP8.5 (2080–2099) revealed significant variation in ECM performance, underscoring the need for targeted retrofit strategies. This study demonstrates the power of combining fTMY projections with large-scale simulations to inform data-driven retrofit planning.

Chowdhury, Shovan [ORNL]↗

Advancing Building Performance: Field Results of Thin-Glass Triple-Pane Window Demonstrations

To meet California and the nation's ambitious energy targets, energy use in the building sector must drop dramatically. Windows continue to be the lowest thermally performing envelope system in the nation's buildings, resulting in poor overall envelope performance and potential impacts to human health and comfort. Current best practice new window performance is typically met by double-pane low-solar-gain glazing. Thin-glass triple-pane windows are a highly promising next step forward in performance and have been deployed in two California multi-family sites to quantify field performance and building energy savings. The technology assessed offers the performance benefits of traditional triple-pane but with little increase in weight or cost, enabling incremental costs competitive with alternative energy reduction solutions for the building envelope. This paper covers a detailed investigation into the demonstration project and measured performance benefits of the windows after a full year of data collection.

Hart, Robert↗

High Contrast Pattern Projection To Enable Background Oriented Schlieren Based Air Leak Detection Through Any Interior Or Exterior Building Surface

Air leakage in buildings wastes an estimated 4 quads of energy per year in the United States. Finding and sealing leakage sites is critical in existing buildings. Previous work has shown that background oriented Schlieren (BOS) imaging can be used to visualize air leakage but requires the leak to exit through a high contrast surface like a brick wall. To remedy this, different techniques of projecting various high contrast patterns on low contrast building surfaces like interior gypsum walls or vinyl siding were investigated. For each technique, the background quality was measured and compared to an ideal printed random dot background. The background quality metrics were correlated with the measured visualization metrics to understand which metrics are most important for maximizing air leak visualization performance. In this work, leakage visualization performance is presented for these various projected backgrounds with an aim to expand the building surfaces suitable for the BOS leak detector.

Jatana, Gurneesh [ORNL] (ORCID:0000000288903225)↗

Sonic-boom-induced building structure responses including damage.

Concepts of sonic-boom pressure loading of building structures and the associated responses are reviewed, and results of pertinent theoretical and experimental research programs are summarized. The significance of sonic-boom load time histories, including waveshape effects, are illustrated with the aid of simple structural elements such as beams and plates. Also included are discussions of the significance of such other phenomena as three-dimensional loading effects, air cavity coupling, multimodal responses, and structural nonlinearities. Measured deflection, acceleration, and strain data from laboratory models and full-scale building tests are summarized, and these data are compared, where possible, with predicted values. Damage complaint and claim experience due both to controlled and uncontrolled supersonic flights over communities are summarized with particular reference to residential, commercial, and historic buildings. Sonic-boom-induced building responses are compared with those from other impulsive loadings due to natural and cultural events and from laboratory simulation tests.

Clarkson, B. L.↗

Initial comparisons of modular-sized, integrated utility systems and conventional systems for several building types

The results of a study of the application of a modular integrated utility system to six typical building types are compared with the application of a conventional utility system to the same facilities. The effects of varying the size and climatic location of the buildings and the size of the powerplants are presented. Construction details of the six building types (garden apartments, a high rise office building, high rise apartments, a shopping center, a high school, and a hospital) and typical site and floor plans are provided. The environmental effects, the unit size determination, and the market potential are discussed. The cost effectiveness of the various design options is not considered.

Benson, H. E.↗

The design of a solar energy collection system to augment heating and cooling for a commercial office building

Analytical studies supported by experimental testing indicate that solar energy can be utilized to heat and cool commercial buildings. In a 50,000 square foot one-story office building at the Langley Research Center, 15,000 square feet of solar collectors are designed to provide the energy required to supply 79 percent of the building heating needs and 52 percent of its cooling needs. The experience gained from the space program is providing the technology base for this project. Included are some of the analytical studies made to make the building design changes necessary to utilize solar energy, the basic solar collector design, collector efficiencies, and the integrated system design.

Basford, R. C.↗

Mean horizontal wind profiles measured in the atmospheric boundary layer about a simulated block building

Instrumented wind towers are used to measure the three components of wind about a simulated block building. The mean horizontal wind profiles over the building are compared with wind profiles measured in the absence of the building and the wind speed deficit in the wake of the building is correlated. The turbulence intensity is of the order of 20% in the undisturbed flow whereas the free stream turbulence intensity of wind-tunnel studies is generally not more than 5%. The velocity profiles measured in the undisturbed flow zones support the representation of a neutrally stable atmospheric boundary layer with a logarithmic wind profile.

Frost, W.↗

Helicopter response in gusty winds about a building

In an earlier work Krynytzky (1971) investigated the performance of a helicopter landing in the steady-state mean flow-field behind a tall building in a wind tunnel. The present paper extends his method to the case of an unsteady flow field. A model is first developed for the gusty wind over a block two-dimensional geometry building. A set of simplified dynamic equations governing the motion of a helicopter is then derived. Finally the performance of the helicopter in an unsteady wind field about the building is computed for the helicopter landing or taking off on a 6 deg glide slope over the building.

Frost, W.↗

Wake characteristics of buildings in disturbed boundary layers

Measurements relevant to the effect of buildings on the low level atmospheric boundary layer are presented. Field measurements of velocity and turbulence in the wake of a block building 3.2 m high and 26.8 m long are presented which show an apparent increase in momentum flow above the upwind value. Velocity-deficit and turbulence-excess decay characteristics of the disturbed or nonequilibrium layer are correlated with power law exponents and apparent roughness length at various distances downstream of the disturbance. Model wake profiles from the simulated building are compared at various stations for equilibrium and nonequilibrium upstream profiles. Empirical correlations relating building wake profiles to upstream nonequilibrium parameters are presented. The relationship of the data to the smooth-rough transition is discussed, and a flow model is presented.

Logan, E., Jr.↗

Wind tunnel measurements of three-dimensional wakes of buildings

Measurements relevant to the effect of buildings on the low level atmospheric boundary layer are presented. A wind tunnel experiment was undertaken to determine the nature of the flow downstream from a gap between two transversely aligned, equal sized models of rectangular cross section. These building models were immersed in an equilibrium turbulent boundary layer which was developed on a smooth floor in a zero longitudinal pressure gradient. Measurements with an inclined (45 degree) hot-wire were made at key positions downstream of models arranged with a large, small, and no gap between them. Hot-wire theory is presented which enables computation of the three mean velocity components, U, V and W, as well as Reynolds stresses. These measurements permit understanding of the character of the wake downstream of laterally spaced buildings. Surface streamline patterns obtained by the oil film method were used to delineate the separation region to the rear of the buildings for a variety of spacings.

Logan, E., Jr.↗

Wakes from arrays of buildings

Experiments were carried out in a small wind tunnel in which atmospheric flow around buildings was simulated. Arrays of one, two, three, and four model buildings were tested, and wake profiles of velocity and turbulence were measured. The data indicate the effect of the buildings on the wind environment encountered by aircraft during landing or takeoff operations. It was possible to use the results to locate the boundaries of the air regions affected by the obstacles and to recommend preferred arrangements of buildings to maximize light safety.