Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Background”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Behaviour and stability of Trivelpiece-Gould modes in non-neutral plasma containing small density fraction of background gas ions

It is shown that the frequencies of Trivelpiece-Gould (TG) modes in non-neutral plasma can get into the low-frequency range due to the Doppler shift caused by plasma rotation in crossed fields. TG modes interact with the ion modes that leads to plasma instability. In paper the frequency spectrum of 'cold' electron plasma completely filling a waveguide and containing small density fraction of ions of background gas is determined numerically. For ions the kinetic description is used. Oscillations having azimuthal number m= 2 are considered. In this case both low- and upper-hybrid TG modes get into the low-frequency range. The spectrum consists of families of 'modified' ion cyclotron (MIC) modes and electron TG modes with the frequencies equal to hybrid frequencies with the Doppler shift. The growth rates of upper-hybrid modes are much faster than the growth rates of low-hybrid and MIC modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A dark-field microscope for background-free detection of resonance fluorescence from single semiconductor quantum dots operating in a set-and-forget mode

Optically active quantum dots, for instance self-assembled InGaAs quantum dots, are potentially excellent single photon sources. The fidelity of the single photons is much improved using resonant rather than non-resonant excitation. With resonant excitation, the challenge is to distinguish between resonance fluorescence and scattered laser light. We have met this challenge by creating a polarization-based dark-field microscope to measure the resonance fluorescence from a single quantum dot at low temperature. We achieve a suppression of the scattered laser exceeding a factor of 10{sup 7} and background-free detection of resonance fluorescence. The same optical setup operates over the entire quantum dot emission range (920–980 nm) and also in high magnetic fields. The major development is the outstanding long-term stability: once the dark-field point has been established, the microscope operates for days without alignment. The mechanical and optical designs of the microscope are presented, as well as exemplary resonance fluorescence spectroscopy results on individual quantum dots to underline the microscope's excellent performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dust acoustic solitons in a charge varying dusty plasma in the presence of ion nonthermality and background nonextensivity

Dust acoustic (DA) solitons are addressed in a charge varying dusty plasma in the presence of ion nonthermality and background nonextensivity. A physically meaningful nonthermal nonextensive ion distribution is outlined. The correct non-Maxwellian ion charging current is derived based on the orbit-limited motion theory. Under grain-current balance, the variable dust charge is expressed in terms of the Lambert function. It is found that nonthermality and its nonextensive nature may act concurrently and influence the restoring force and hence the soliton profile. Due to the flexibility provided by the nonextensive parameter, we think that our model should provide a better fit of the space observations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low background HPGe spectrometer in investigations of 2β decay

The low background high sensitive HPGe spectrometer called OBELIX is briefly described. The calibration measurements using {sup 152}Eu, {sup 133}Ba and La{sub 2}O{sub 3} sources in different geometries, the obtained efficiency curves for OBELIX HPGe detector, the results of measurements of radioactivity of the NEMO-3 sources ({sup 100}Mo, {sup 150}Nd) as well as future plans for OBELIX detector (e.g. 0νEC/EC decay of {sup 106}Cd) are presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

GERDA phase II detectors: Behind the production and characterisation at low background conditions

The low background GERmanium Detector Array (GERDA) at Laboratori Nazionali del Gran Sasso (LNGS) is designed to search for the rare neutrinoless double beta decay (0νββ) in {sup 76}Ge. Bare germanium diodes are operated in liquid argon which is used as coolant, as passive and soon active as well shield against external radiation. Currently, Phase I of the experiment is running using ∼15 kg of co-axial High Purity Germanium diodes. In order to increase the sensitivity of the experiment 30 Broad Energy Germanium (BEGe) diodes will be added within 2013. This presentation reviews the production chain of the new BEGe detectors from isotopic enrichment to diode production and testing. As demonstrated all steps were carefully planned in order to minimize the exposure of the enriched germanium to cosmic radiation. Following this premise, acceptance and characterisation measurement of the newly produced diodes have been performed within the HEROICA project in the Belgian underground laboratory HADES close to the diode manufacturer. The test program and the results from a subset of the recently terminated GERDA Phase II BEGe survey will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low background high efficiency radiocesium detection system based on positron emission tomography technology

After the 2011 nuclear power plant accident at Fukushima, radiocesium contamination in food became a serious concern in Japan. However, low background and high efficiency radiocesium detectors are expensive and huge, including semiconductor germanium detectors. To solve this problem, we developed a radiocesium detector by employing positron emission tomography (PET) technology. Because {sup 134}Cs emits two gamma photons (795 and 605 keV) within 5 ps, they can selectively be measured with coincidence. Such major environmental gamma photons as {sup 40}K (1.46 MeV) are single photon emitters and a coincidence measurement reduces the detection limit of radiocesium detectors. We arranged eight sets of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillation detectors in double rings (four for each ring) and measured the coincidence between these detectors using PET data acquisition system. A 50 × 50 × 30 mm BGO was optically coupled to a 2 in. square photomultiplier tube (PMT). By measuring the coincidence, we eliminated most single gamma photons from the energy distribution and only detected those from {sup 134}Cs at an average efficiency of 12%. The minimum detectable concentration of the system for the 100 s acquisition time is less than half of the food monitor requirements in Japan (25 Bq/kg). These results show that the developed radiocesium detector based on PET technology is promising to detect low level radiocesium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Investigations of 2β decay measured by low background HPGe spectrometer OBELIX

A low background high sensitive HPGe spectrometer OBELIX was installed at the Modane Underground Laboratory (LSM, France, 4800 m w.e.). The detector was designed to measure a contamination of enriched isotopes and radio-impurities in construction materials, to investigate rare nuclear processes such as resonance neutrinoless double electron capture and two-neutrino double beta decay to excited states of daughter nuclei. Spectrometer sensitivity, contamination of NEMO-3 sources and results of 2ν2β{sup −} decay of {sup 100}Mo to the 0{sup +} (1130 keV) and 2{sup +} (540 keV) excited states as well as future plans for OBELIX detector are given.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Effect of quantum dot position and background doping on the performance of quantum dot enhanced GaAs solar cells

The effect of the position of InAs quantum dots (QD) within the intrinsic region of pin-GaAs solar cells is reported. Simulations suggest placing the QDs in regions of reduced recombination enables a recovery of open-circuit voltage (V{sub OC}). Devices with the QDs placed in the center and near the doped regions of a pin-GaAs solar cell were experimentally investigated. While the V{sub OC} of the emitter-shifted device was degraded, the center and base-shifted devices exhibited V{sub OC} comparable to the baseline structure. This asymmetry is attributed to background doping which modifies the recombination profile and must be considered when optimizing QD placement.

36 MATERIALS SCIENCE↗

Plasma tomographic reconstruction from tangentially viewing camera with background subtraction

Light reflections are one of the main and often underestimated issues of plasma emissivity reconstruction in visible light spectral range. Metallic and other specular components of tokamak generate systematic errors in the optical measurements that could lead to wrong interpretation of data. Our analysis is performed at data from the tokamak COMPASS. It is a D-shaped tokamak with specular metallic vessel and possibility of the H-mode plasma. Data from fast visible light camera were used for tomographic reconstruction with background reflections subtraction to study plasma boundary. In this article, we show that despite highly specular tokamak wall, it is possible to obtain a realistic reconstruction. The developed algorithm shows robust results despite of systematic errors in the optical measurements and calibration. The motivation is to obtain an independent estimate of the plasma boundary shape.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Diffusion-assisted selective dynamical recoupling: A new approach to measure background gradients in magnetic resonance

Dynamical decoupling, a generalization of the original NMR spin-echo sequence, is becoming increasingly relevant as a tool for reducing decoherence in quantum systems. Such sequences apply non-equidistant refocusing pulses for optimizing the coupling between systems, and environmental fluctuations characterized by a given noise spectrum. One such sequence, dubbed Selective Dynamical Recoupling (SDR) [P. E. S. Smith, G. Bensky, G. A. Álvarez, G. Kurizki, and L. Frydman, Proc. Natl. Acad. Sci. 109, 5958 (2012)], allows one to coherently reintroduce diffusion decoherence effects driven by fluctuations arising from restricted molecular diffusion [G. A. Álvarez, N. Shemesh, and L. Frydman, Phys. Rev. Lett. 111, 080404 (2013)]. The fully-refocused, constant-time, and constant-number-of-pulses nature of SDR also allows one to filter out “intrinsic” T{sub 1} and T{sub 2} weightings, as well as pulse errors acting as additional sources of decoherence. This article explores such features when the fluctuations are now driven by unrestricted molecular diffusion. In particular, we show that diffusion-driven SDR can be exploited to investigate the decoherence arising from the frequency fluctuations imposed by internal gradients. As a result, SDR presents a unique way of probing and characterizing these internal magnetic fields, given an a priori known free diffusion coefficient. This has important implications in studies of structured systems, including porous media and live tissues, where the internal gradients may serve as fingerprints for the system's composition or structure. The principles of this method, along with full analytical solutions for the unrestricted diffusion-driven modulation of the SDR signal, are presented. The potential of this approach is demonstrated with the generation of a novel source of MRI contrast, based on the background gradients active in an ex vivo mouse brain. Additional features and limitations of this new method are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quasi-bound states and continuum absorption background of polar Al{sub 0.5}Ga{sub 0.5}N/GaN quantum dots

A theoretical interpretation of the photoluminescence excitation spectra of self-organized polar GaN/(Al,Ga)N quantum dots is presented. A numerical method assuming a realistic shape of the dots and including the built-in electric field effects is developed to calculate their energy structure and hence their optical absorption. The electron and hole spectra show the existence of a set of quasi-bound states that does not originate from the wetting layer and plays a crucial role in the observed absorption spectrum of the GaN/(Al,Ga)N dots. Transitions involving these quasi-bound states and wetting layer states give a sufficient explanation for the observed continuum absorption background. The properties of this absorption band, especially its extension, depend strongly on the dot's size. Our simulation provides a natural explanation of the experimental luminescence excitation spectra of ensembles of dots of different heights. Our theoretical model can be convenient for future optical studies including systems with more complicated potentials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Light output function and assembly of the time-of-flight enhanced diagnostics neutron spectrometer plastic scintillators for background reduction by double kinematic selection at EAST

The 2.5 MeV neutron spectrometer TOFED (Time-Of-Flight Enhanced Diagnostics) has been constructed to perform advanced neutron emission spectroscopy diagnosis of deuterium plasmas on EAST. The instrument has a double-ring structure which, in combination with pulse shape digitization, allows for a dual kinematic selection in the time-of-flight/recoil proton energy (tof/E{sub p}) space, thus improving the spectrometer capability to resolve fast ion signatures in the neutron spectrum, in principle up to a factor ≈100. The identification and separation of features from the energetic ions in the neutron spectrum depends on the detailed knowledge of the instrument response function, both in terms of the light output function of the scintillators and the effect of undesired multiple neutron scatterings in the instrument. This work presents the determination of the light output function of the TOFED plastic scintillator detectors and their geometrical assembly. Results from dedicated experiments with γ-ray sources and quasi-monoenergetic neutron beams are presented. Implications on the instrument capability to perform background suppression based on double kinematic selection are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Time-reversal symmetric resolution of unity without background integrals in open quantum systems

We present a new complete set of states for a class of open quantum systems, to be used in expansion of the Green’s function and the time-evolution operator. A remarkable feature of the complete set is that it observes time-reversal symmetry in the sense that it contains decaying states (resonant states) and growing states (anti-resonant states) parallelly. We can thereby pinpoint the occurrence of the breaking of time-reversal symmetry at the choice of whether we solve Schrödinger equation as an initial-condition problem or a terminal-condition problem. Another feature of the complete set is that in the subspace of the central scattering area of the system, it consists of contributions of all states with point spectra but does not contain any background integrals. In computing the time evolution, we can clearly see contribution of which point spectrum produces which time dependence. In the whole infinite state space, the complete set does contain an integral but it is over unperturbed eigenstates of the environmental area of the system and hence can be calculated analytically. We demonstrate the usefulness of the complete set by computing explicitly the survival probability and the escaping probability as well as the dynamics of wave packets. The origin of each term of matrix elements is clear in our formulation, particularly, the exponential decays due to the resonance poles.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

How difficult it would be to detect cosmic neutrino background?

Possible ways of detecting the cosmic neutrino background are described and their difficulties discussed. Among them, the capture on the radioactive tritium nuclei is challenging, but perhaps doable. The principal difficulty is the need for the combination of a very strong source and very good detector resolution. It is argued that if it turns out that the neutrino masses follow the degenerate scenario, i.e. if m{sub ν} ≥ 0.1 eV for all three massive neutrinos, then it is important to devote a substantial effort to develop a realistic detection experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Theoretical analysis of the background intensity distribution in X-ray Birefringence Imaging using synchrotron bending-magnet radiation

In the recently developed technique of X-ray Birefringence Imaging, molecular orientational order in anisotropic materials is studied by exploiting the birefringence of linearly polarized X-rays with energy close to an absorption edge of an element in the material. In the experimental setup, a vertically deflecting high-resolution double-crystal monochromator is used upstream from the sample to select the appropriate photon energy, and a horizontally deflecting X-ray polarization analyzer, consisting of a perfect single crystal with a Bragg reflection at Bragg angle of approximately 45°, is placed downstream from the sample to measure the resulting rotation of the X-ray polarization. However, if the experiment is performed on a synchrotron bending-magnet beamline, then the elliptical polarization of the X-rays out of the electron orbit plane affects the shape of the output beam. Also, because the monochromator introduces a correlation between vertical position and photon energy to the X-ray beam, the polarization analyzer does not select the entire beam, but instead selects a diagonal stripe, the slope of which depends on the Bragg angles of the monochromator and the polarization analyzer. In the present work, the final background intensity distribution is calculated analytically because the phase space sampling methods normally used in ray traces are too inefficient for this setup. X-ray Birefringence Imaging data measured at the Diamond Light Source beamline B16 agree well with the theory developed here.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Study of the Kroll-process to produce ultra-pure Ti for the low background experiments

To construct G2 & G3 low background experiments for direct Dark Matter search, a lot of ultra-pure construction materials will be needed. Our study of various Ti samples shows that the levels of contaminations of commercially available industrial Ti can varies from 0.2 to 100 mBq/kg for U/Th. It means that the metal Ti is such a promising material for future experiments if the way of production in bulk quantities with very low level of contaminations (below ∼1 mBq/kg of {sup 238}U /{sup 232}Th) would be developed. Our study of the industrial Kroll-process is focused on the possible sources of U and Th and their migration during the multistage Kroll process. To understand migration of U and Th during the Kroll process the set of other impurities available due to precise ICP-MS analysis have been studied. Preliminary results confirm that the Kroll process could be used for the ultra pure Ti sponge production while the following stages of the metal Ti production of from the Ti sponge with necessary mechanical properties need to be additionally studied.

36 MATERIALS SCIENCE↗

FLUKA: Predictive power for cosmogenic backgrounds

The next generation of experiments searching for rare physics events with increased sensitivity will require precise predictions of cosmogenic backgrounds. Recent high quality deep underground measurements for cosmogenic neutrons in large liquid scintillator targets were used to study the FLUKA simulation package for this purpose. The results and conclusions drawn from a detailed benchmark comparison with data from the Borexino experiment were reported recently. In general, good agreement between data and simulation results were found with some identified discrepancies. Improved physics models already implemented in the current version of the FLUKA code, which will be publicly available with the upcoming code release, address the more important identified issues. A careful evaluation of the improved predictions is ongoing. However, the agreement between preliminary FLUKA simulation results and the Borexino experimental data are excellent. The preliminary findings will be discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Background analysis and status of the ANAIS dark matter project

ANAIS (Annual modulation with NaI Scintillators) is a project aiming to set up at the new facilities of the Canfranc Underground Laboratory (LSC), a large scale NaI(Tl) experiment in order to explore the DAMA/LIBRA annual modulation positive result using the same target and technique. Two 12.5 kg each NaI(Tl) crystals provided by Alpha Spectra took data at the LSC in the ANAIS-25 set-up. The comparison of the background model for the ANAIS-25 prototypes with the experimental results is presented. ANAIS crystal radiopurity goals have been achieved for {sup 232}Th and {sup 238}U chains, but a {sup 210}Pb contamination out-of-equilibrium was identified, whose origin has been studied. The high light collection efficiency obtained with these prototypes allows to anticipate an energy threshold of the order of 1 keVee. A new detector, with improved performances, was received in March 2015 and very preliminary results are shown.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗