Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “BACKGROUND RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Muon Collider Machine-Detector Interface

In order to realize the high physics potential of a Muon Collider (MC) a high luminosity of {mu}{sup +}{mu}{sup -}-collisions at the Interaction Point (IP) in the TeV range must be achieved ({approx}10{sup 34} cm{sup -2}s{sup -1}). To reach this goal, a number of demanding requirements on the collider optics and the IR hardware - arising from the short muon lifetime and from relatively large values of the transverse emittance and momentum spread in muon beams that can realistically be obtained with ionization cooling should be satisfied. These requirements are aggravated by limitations on the quadrupole gradients as well as by the necessity to protect superconducting magnets and collider detectors from muon decay products. The overall detector performance in this domain is strongly dependent on the background particle rates in various sub-detectors. The deleterious effects of the background and radiation environment produced by the beam in the ring are very important issues in the Interaction Region (IR), detector and Machine-Detector Interface (MDI) designs. This report is based on studies presented very recently.

43 PARTICLE ACCELERATORS↗

A radon progeny deposition model

The next generation low-background detectors operating underground aim for unprecedented low levels of radioactive backgrounds. Although the radioactive decays of airborne radon (particularly {sup 222}Rn) and its subsequent progeny present in an experiment are potential backgrounds, also problematic is the deposition of radon progeny on detector materials. Exposure to radon at any stage of assembly of an experiment can result in surface contamination by progeny supported by the long half life (22 y) of {sup 210}Pb on sensitive locations of a detector. An understanding of the potential surface contamination from deposition will enable requirements of radon-reduced air and clean room environments for the assembly of low background experiments. It is known that there are a number of environmental factors that govern the deposition of progeny onto surfaces. However, existing models have not explored the impact of some environmental factors important for low background experiments. A test stand has been constructed to deposit radon progeny on various surfaces under a controlled environment in order to develop a deposition model. Results from this test stand and the resulting deposition model are presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Spectral Components Analysis of Diffuse Emission Processes

We develop a novel method to separate the components of a diffuse emission process based on an association with the energy spectra. Most of the existing methods use some information about the spatial distribution of components, e.g., closeness to an external template, independence of components etc., in order to separate them. In this paper we propose a method where one puts conditions on the spectra only. The advantages of our method are: 1) it is internal: the maps of the components are constructed as combinations of data in different energy bins, 2) the components may be correlated among each other, 3) the method is semi-blind: in many cases, it is sufficient to assume a functional form of the spectra and determine the parameters from a maximization of a likelihood function. As an example, we derive the CMB map and the foreground maps for seven yeas of WMAP data. In an Appendix, we present a generalization of the method, where one can also add a number of external templates.

79 ASTRONOMY AND ASTROPHYSICS↗

MCNP6 Cosmic & Terrestrial Background Particle Fluxes -- Release 4

Essentially a set of slides, the presentation begins with the MCNP6 cosmic-source option, then continues with the MCNP6 transport model (atmospheric, terrestrial) and elevation scaling. It concludes with a few slides on results, conclusions, and suggestions for future work.

79 ASTRONOMY AND ASTROPHYSICS↗

The DAMIC Dark Matter Experiment

The DAMIC (DArk Matter In CCDs) experiment uses high-resistivity, scientific-grade CCDs to search for dark matter. The CCD’s low electronic noise allows an unprecedently low energy threshold of a few tens of eV; this characteristic makes it possible to detect silicon recoils resulting from interactions of low-mass WIMPs. In addition, the CCD’s high spatial resolution and the excellent energy response results in very effective background identification techniques. The experiment has a unique sensitivity to dark matter particles with masses below 10 GeV/c 2 . Previous results have motivated the construction of DAMIC100, a 100 grams silicon target detector currently being installed at SNOLAB. The mode of operation and unique imaging capabilities of the CCDs, and how they may be exploited to characterize and suppress backgrounds are discussed, as well as physics results after one year of data taking.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Validation testing of the Canberra mobile Feed Roll Assay system - 15404

Japanese farmers grow various grasses as feed for cattle. These are rolled up and sealed for future use. Canberra has created a special truck to monitor these Feed Rolls, called 'Feed Roll Assay System [FRAS]'. On the bed of the truck is the shield containing a large NaI detector. The detector is 3x5x16'' in size, the same size as used in the Canberra FastScan Whole Body Counter. The detector is also LED-stabilized, to keep the gain constant under the wide range of temperature variations expected for this outdoor measurement instrument. The Canberra Osprey digital MCA is connected to the detector. The detector and the MCA are housed in a water proof box, which is surrounded on the bottom and all sides by a 15 cm thick steel shield. A portion of the shield at the top is open where the detector can view the Feed Rolls placed there. A single ethernet cable goes to a laptop PC which provides power to the MCA and detector, and also transmits the signal to the PC. The system was calibrated using MCNP for a variety of different densities, and Feed Roll sizes. The Japanese version of the Canberra Genie software is used to analyze the spectra and compute the Bq/kg concentration of the Feed Roll. The shielding is sufficient so that at a 5 uSv/hr background dose rate, no Cs-137 or Cs-134 peaks were detected in a 1 hour count. Measurements were performed in 0.2 uSv/hr dose rate, using uncontaminated Feed Rolls at various counting times. The MDA for Cs-137 was 11.9 Bq/kg at 30 seconds, 8.2 Bq/kg for 60 seconds, and 1.1 Bq/kg at 3600 seconds count time. The relative measurement uncertainty of the FRAS measurements was 9.4 to 13%, as compared to assays of samples extracted [30-45%] and in-situ Ge measurements [6.0 - 7.1%]. The FRAS measurement results have considerably better precision than measurements of samples extracted from the Feed Rolls, and are much faster than the in-situ Ge measurements and have just about the same uncertainty. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of Nuclear Structure Functions at Jefferson Lab

This thesis presents a study of nuclear modification of quark distributions (the EMC effect) using inclusive electron-scattering data from Jefferson Lab Hall C, with emphasis on experiment E12-10-008 (XEM2). The analysis spans nuclei from light to heavy targets and combines measurements at multiple spectrometer settings to constrain EMC ratios over a broad range in Bjorken-x and Q2. A complete analysis framework was developed to extract charge-normalized and efficiency-corrected yields, including detector calibrations, beam-current calibration, density-loss corrections for cryogenic targets, background subtraction, radiative and Coulomb corrections, and systematic studies. Instrumental cross-checks, including HMS–SHMS comparisons and reconstruction studies, show that residual spectrometer differences are predominantly multiplicative in the kinematic region relevant to the EMC analysis. The extracted EMC ratios are broadly consistent with previous measurements while extending coverage across many nuclei. The EMC slope increases from light to heavy nuclei and shows signs of saturation at large A. After accounting for the dominant A dependence, the results are consistent with no isospin dependence, but also consistent with the predicted modification from the isovector model.

Sharda, Abhyuday [Univ. of Tennessee, Knoxville, T↗

An Improved Design for a Super-B Interaction Region

We present an improved design for a Super-B interaction region. The new design attempts to minimize the bending of the two colliding beams which results from shared magnetic elements near the Interaction Point (IP). The total crossing angle at the IP is increased from 34 mrad to 50 mrad and the distance from the IP to the first quadrupole is increased. Although the two beams still travel through this shared magnet, these changes allow for a new magnetic field design with a septum which gives the magnet two magnetic centers. This greatly reduces the beam bending from this shared quadrupole and thereby reduces the radiative bhabha background for the detector as well as any beam emittance growth from the bending. We describe the new design for the interaction region.

43 PARTICLE ACCELERATORS↗

SPECTRAL RELATIVE ABSORPTION DIFFERENCE METHOD

When analyzing field data, the uncertainty in the background continuum emission produces the majority of error in the final gamma-source analysis. The background emission typically dominates an observed spectrum in terms of counts and is highly variable spatially and temporally. The majority of the spectral shape of the background continuum is produced by combinations of cosmic rays, {sup 40}K, {sup 235}U, and {sup 220}Rn, and the continuum is similar in shape to the 15%-20% level for most field observations. However, the goal of spectroscopy analysis is to pick up subtle peaks (<%5) upon this large background. Because the continuum is falling off as energy increases, peak detection algorithms must first define the background surrounding the peak. This definition is difficult when the range of background shapes is considered. The full spectral template matching algorithms are heavily weighted to solving for the background continuum as it produces significant counts over much of the energy range. The most appropriate background mitigation technique is to take a separate background observation without the source of interest. But, it is frequently not possible to record a background observation in the exact location before (or after) a source has been detected. Thus, one uses approximate backgrounds that rely on spatially nearby locations or similar environments. Since the error in many field observations is dominated by the background, a technique that is less sensitive to the background would be quite beneficial. We report the result of an initial investigation into a novel observation scheme for gamma-emission detection in high background environments. Employing low resolution, NaI, detectors, we examine the different between the direct emission and the 'spectral-shadow' that the gamma emission produces when passed through a thin absorber. For this detection scheme to be competitive, it is required to count and analyze individual gamma-events. We describe the unique instrumental setup which we assembled to make these measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmology on the Beach - Carlos Frenk, Lecture 3

The lecture was delivered as part of the "Cosmology at the Beach" winter school organized by Berkeley Lab's George Smoot in Los Cabos, Mexico from Jan. 12-16, 2009.

79 ASTRONOMY AND ASTROPHYSICS↗

The diffuse UV background

The diffuse radiation field in the UV (900-3,000 A) affects the structure of galactic molecular clouds and conveys important information concerning the physical characteristics and spatial distribution of gas and dust in the universe. Continuum emission in this range is probably dominated by interstellar dust scattering in our galaxy. For view directions and angular resolutions allowing observations in the rifts between galactic dust clouds, the background due to the integrated light of spiral galaxies may be detected, providing important information on their structure and evolution. The redshifted emission from an intergalactic medium may be observable in the regions between nearby bright galaxies. Present observations provide weak constraints on the radiation field required to ionize the intergalactic medium at the level required by the Gunn-Peterson test.

Paresce, F.↗

Optimal Background Attenuation for Fielded Spectroscopic Detection Systems

Radiation detectors are often placed in positions difficult to shield from the effects of terrestrial background gamma radiation. This is particularly true in the case of Radiation Portal Monitor (RPM) systems, as their wide viewing angle and outdoor installations make them susceptible to radiation from the surrounding area. Reducing this source of background can improve gross-count detection capabilities in the current generation of non-spectroscopic RPM’s as well as source identification capabilities in the next generation of spectroscopic RPM’s. To provide guidance for designing such systems, the problem of shielding a general spectroscopic-capable RPM system from terrestrial gamma radiation is considered. This analysis is carried out by template matching algorithms, to determine and isolate a set of non-threat isotopes typically present in the commerce stream. Various model detector and shielding scenarios are calculated using the Monte-Carlo N Particle (MCNP) computer code. Amounts of nominal-density shielding needed to increase the probability of detection for an ensemble of illicit sources are given. Common shielding solutions such as steel plating are evaluated based on the probability of detection for 3 particular illicit sources of interest, and the benefits are weighed against the incremental cost of shielding. Previous work has provided optimal shielding scenarios for RPMs based on gross-counting measurements, and those same solutions (shielding the internal detector cavity, direct shielding of the ground between the detectors, and the addition of collimators) are examined with respect to their utility to improving spectroscopic detection.

36 MATERIALS SCIENCE↗

Angle-Selective Reflective Filters for Exclusion of Background Thermal Emission

Selective filtering of spectral and angular optical transmission has recently attracted a great deal of interest. While optical passband and stop-band spectral filters are already widely used, angle-selective transmission and reflection filtering represents a less than fully explored alternative. Nonetheless, this approach can be promising for several applications, including stray radiation minimization and background emission exclusion. In this work, a concept for angle-selective reflection filtering using guided-mode resonance coupling is proposed. Although guided-mode resonance structures are already used for spectral filtering, in this work, a variation of angle-selective reflection filtering using guided-mode resonance coupling is proposed. We investigate angle-dependent properties of such structures for potential use as angle-selective reflective filters. Furthermore, we utilize interference between diffraction modes to provide tunable selectivity with a sufficient angular width. Combining these structures with thermal emitters can exclude selected emission angles for spatially selective thermal emissivity reduction toward sensitive targets, as well as directionally selective emissivity exclusion for suppression of solar heating. We show a very large selective reduction of heat exchange by 99.77% between an engineered emitter and a distant receiver using just a single-groove grating and an emitting substrate in the emitter’s side. Also, we show a selective reduction of heat exchange by approximately 77% between an emitter covered by engineered sets of angle-selective reflective filters and a nearby sensitive target. The suggested angle-selective structure may have applications in excluding background thermal radiation, in particular, thermal emission reduction for daytime radiative cooling, sensitive IR telescope detectors, and high-fidelity thermoluminescent spectroscopy.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

An upper bound from helioseismology on the stochastic background of gravitational waves

The universe is expected to be permeated by a stochastic background of gravitational radiation of astrophysical and cosmological origin. This background is capable of exciting oscillations in solar-like stars. Here we show that solar-like oscillators can be employed as giant hydrodynamical detectors for such a background in the μHz to mHz frequency range, which has remained essentially unexplored until today. We demonstrate this approach by using high-precision radial velocity data for the Sun to constrain the normalized energy density of the stochastic gravitational-wave background around 0.11 mHz. These results open up the possibility for asteroseismic missions like CoRoT and Kepler to probe fundamental physics.

79 ASTRONOMY AND ASTROPHYSICS↗