Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “66”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,657 records · Page 92

Comparison of Propane and Methane Performance and Emissions in a Turbocharged Direct Injection Dual Fuel Engine

With increasingly restrictive NO x and particulate matter emissions standards, the recent discovery of new natural gas reserves, and the possibility of producing propane efficiently from biomass sources, dual fueling strategies have become more attractive. This paper presents experimental results from dual fuel operation of a four-cylinder turbocharged direct injection (DI) diesel engine with propane or methane (a natural gas surrogate) as the primary fuel and diesel as the ignition source. Experiments were performed with the stock engine control unit at a constant speed of 1800 rpm, and a wide range of brake mean effective pressures (BMEPs) (2.7-11.6 bars) and percent energy substitutions (PESs) of C 3 H 8 and CH 4. Brake thermal efficiencies (BTEs) and emissions (NO x, smoke, total hydrocarbons (THCs), CO, and CO 2) were measured. Maximum PES levels of about 80-95% with CH 4 and 40-92% with C 3 H 8 were achieved. Maximum PES was limited by poor combustion efficiencies and engine misfire at low loads for both C 3 H 8 and CH 4, and the onset of knock above 9 bar BMEP for C 3 H 8. While dual fuel BTEs were lower than straight diesel BTEs at low loads, they approached diesel BTE values at high loads. For dual fuel operation, NO x and smoke reductions (from diesel values) were as high as 66-68% and 97%, respectively, but CO and THC emissions were significantly higher with increasing PES at all engine loads

Biomass source↗

Evaluation of Power Transmission Lines Hardening Scenarios Using a Machine Learning Approach

The power transmission infrastructure is vulnerable to extreme weather events, particularly hurricanes and tropical storms. A recent example is the damage caused by Hurricane Maria (H-Maria) in the archipelago of Puerto Rico in September 2017, where major failures in the transmission infrastructure led to a total blackout. Numerous studies have been conducted to examine strategies to strengthen the transmission system, including burying the power lines underground or increasing the frequency of tree trimming. However, few studies focus on the direct hardening of the transmission towers to accomplish an increase in resiliency. This machine learning-based study fills this need by analyzing three direct hardening scenarios and determining the effectiveness of these changes in the context of H-Maria. A methodology for estimating transmission tower damage is presented here in this study as well as an analysis of impact of replacing structures with a high failure rate with more resilient ones. We found the steel self-support-pole to be the best replacement option for the towers with high failure rate. Furthermore, the third hardening scenario, where all wooden poles were replaced, exhibited a maximum reduction in damaged towers in a single line of 66% while lowering the mean number of damaged towers per line by 10%.

54 ENVIRONMENTAL SCIENCES↗

Solids Mobilization and Suspension by Dual Opposed Mixing Pumps

Experiments were performed to support understanding mixing of radioactive waste stored in Tank 241-SY-101 at the Hanford Site in Washington State. These experiments were conducted at 1/12 scale and modeled the tank and proposed mixing pump. The tests investigated solids mobilization and suspension for jets rotated in fixed increments about the tank centerline. Flow visualization tests showed that the supernatant layer was generally too cloudy for effective visualization. Observations of the settled solids interface during a start-up transient showed that the mixing action was always confined within the slurry layer. A 4.57-m/s (15-ft/s) jet velocity was not capable of clearing settled sludge off the tank floor all the way to the tank wall and produced a stratified flow field at steady state; 7.62-m/s (25-ft/s) and higher jet velocities always circulated solids to the tank surface. During the operating parameter tests with jets rotated at fixed increments, the slurry interface rose more slowly than for the fixed location jets. Solids suspension was more effective for the rotated jets than for the fixed location jets. Percent solids suspended with a 7.62-m/s (25-ft/s) jet was 66 to 72% in the high viscosity simulant and 59 to 67% in the low viscosity simulant. Percent solids suspended with a 15.2 m/s (50-ft/s) jet was 74 to 81% in the low viscosity simulant. A 7.62 m/s (25-ft/s) jet velocity was adequate to clear settled solids from the tank floor to the tank wall for both the low and high viscosity simulant.

concentration profile↗

ANALYSIS OF A HIGH TEMPERATURE GAS-COOLED REACTOR POWERED HIGH TEMPERATURE ELECTROLYSIS HYDROGEN PLANT

An updated reference design for a commercial-scale high-temperature electrolysis (HTE) plant for hydrogen production has been developed. The HTE plant is powered by a high-temperature gas-cooled reactor (HTGR) whose configuration and operating conditions are based on the latest design parameters planned for the Next Generation Nuclear Plant (NGNP). The current HTGR reference design specifies a reactor power of 600 MWt, with a primary system pressure of 7.0 MPa, and reactor inlet and outlet fluid temperatures of 322°C and 750°C, respectively. The reactor heat is used to produce heat and electric power to the HTE plant. A Rankine steam cycle with a power conversion efficiency of 44.4% was used to provide the electric power. The electrolysis unit used to produce hydrogen includes 1.1 million cells with a per-cell active area of 225 cm2. The reference hydrogen production plant operates at a system pressure of 5.0 MPa, and utilizes a steam-sweep system to remove the excess oxygen that is evolved on the anode (oxygen) side of the electrolyzer. The overall system thermal-to-hydrogen production efficiency (based on the higher heating value of the produced hydrogen) is 42.8% at a hydrogen production rate of 1.85 kg/s (66 million SCFD) and an oxygen production rate of 14.6 kg/s (33 million SCFD). An economic analysis of this plant was performed with realistic financial and cost estimating The results of the economic analysis demonstrated that the HTE hydrogen production plant driven by a high-temperature helium-cooled nuclear power plant can deliver hydrogen at a competitive cost. A cost of $3.03/kg of hydrogen was calculated assuming an internal rate of return of 10% and a debt to equity ratio of 80%/20% for a reactor cost of $2000/kWt and $2.41/kg of hydrogen for a reactor cost of $1400/kWt.

08 HYDROGEN↗

Plasma enhanced atomic layer deposition of thin film Li 1+x Mn 2-x O 4 for realization of all solid-state 3D lithium-ion microbatteries

Here, the plasma enhanced atomic layer deposition (PEALD) process for MnO 2 was demonstrated, exhibiting self-limiting growth as well as stable composition and stable growth rate over a temperature window of 205–265 °C. The PEALD process for MnO 2 was combined with the thermal ALD process for LiOH to synthesize Li 1+x Mn 2-x O 4 thin film cathodes, where the stoichiometry was effectively controlled to allow for crystallization in the electrochemically active spinel phase. A 3D nanostructure consisting of an Li 1+x Mn 2-x O 4 cathode layer, ALD Li x Al y Si z O solid electrolyte, and SiGe nanowire anode was fabricated and characterized via TEM. The Li 1+x Mn 2-x O 4 thin films maintained 66% of the areal capacity upon a 100× increase in the rate (4–360 μ A cm -2 ) as well as 97% capacity retention over 100 cycles at ~5C. The ALD Li 1+x Mn 2-x O 4 thin films exhibited a volumetric capacity of 52 μ Ah cm -2 μ m -1 at a C-rate of ~0.5C and, coupled with the high operating voltage (4.0 V), offer some of best areal energy densities for ALD thin film cathodes, making it a viable material for integration with 3D lithium-ion microbatteries.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Insufficient reporting of x-ray photoelectron spectroscopy instrumental and peak fitting parameters (metadata) in the scientific literature

This study was motivated by earlier observations. It is a systematic examination of the adequacy of reporting of information (metadata) necessary to understand x-ray photoelectron spectroscopy (XPS) data collection and data analysis in the scientific literature. The information for this study was obtained from papers published in three high-quality journals over a six-month period in 2019 and throughout 2021. Each paper was evaluated to determine whether the authors had reported (percentages of the papers properly providing the information are given in parentheses) the spectrometer (66%), fitting software (15%), x-ray source (40%), pass energy (10%), spot size (5%), synthetic peak shapes in fits (10%), backgrounds in fits (10%), whether the XPS data are shown in the main body of the paper or in the supporting information (or both), and whether fitted or unfitted spectra were shown (80% of published spectra are fit). The Shirley background is the most widely used background in XPS peak fitting. The Al Kα source is the most widely used x-ray source for XPS data collection. CASAXPS is the most widely used fitting program for XPS data analysis. Further, there is good agreement between the results gathered during the two years of our survey. There are some hints the situation may be improving. This study also provides a list of the information/parameters that should be reported when XPS is performed.

47 OTHER INSTRUMENTATION↗

Synthesis and characterization of electron beam irradiation-induced damage in polycrystalline metal thin films

High-energy physics research, industrial sterilizing, and material processing depend extensively on electron beam accelerators. Exit windows are crucial components of such electron accelerator systems, maintaining vacuum integrity inside the machine while providing mechanical strength, thermal stability, and radiation resistance at the beam-target interface. In this study, thin metallic films of Ni, Ti, Cr, and V were explored for use in electron beam exit windows, and their properties were compared with the properties of their bulk counterparts. Simulation results of metal foils predicted Ti to exhibit less beam power dissipation compared to Ni. However, Ni possesses superior mechanical and structural properties compared to Ti. The performance of these films under electron beam irradiation was examined by depositing thin layers of these films on silicon and metallic substrates using magnetron sputtering and exposing them to e-beam irradiation in a controlled setup. The deposited films were subjected to a dose of approximately 66 kGy at a beam energy of 10 MeV and characterized prior to and postexposure to the beam using field emission scanning electron microscopy, atomic force microscopy, x-ray diffraction (XRD), and nanoindentation. Particular emphasis was given to characteristics like the grain structure, surface morphology, dislocation density, and hardness. XRD patterns revealed irradiation-induced changes in peak intensities, while the crystallinity remained largely unchanged. Nanoindentation results showed that the pristine and irradiated Ti and Ni films were twice as hard when compared to bulk Ti and Ni samples, regardless of the substrate type used (Si or bulk Ti, or Ni). These results emphasize the superior mechanical properties of thin metal films compared to their bulk counterparts. In conclusion, this study advances the optimization of thin film materials for robust and efficient e-beam applications, ensuring improved durability and operational reliability.

AFM↗

Segmentation of pulmonary nodules in three-dimensional CT images by use of a spiral-scanning technique

Accurate segmentation of pulmonary nodules in computed tomography (CT) is an important and difficult task for computer-aided diagnosis of lung cancer. Therefore, the authors developed a novel automated method for accurate segmentation of nodules in three-dimensional (3D) CT. First, a volume of interest (VOI) was determined at the location of a nodule. To simplify nodule segmentation, the 3D VOI was transformed into a two-dimensional (2D) image by use of a key 'spiral-scanning' technique, in which a number of radial lines originating from the center of the VOI spirally scanned the VOI from the 'north pole' to the 'south pole'. The voxels scanned by the radial lines provided a transformed 2D image. Because the surface of a nodule in the 3D image became a curve in the transformed 2D image, the spiral-scanning technique considerably simplified the segmentation method and enabled reliable segmentation results to be obtained. A dynamic programming technique was employed to delineate the 'optimal' outline of a nodule in the 2D image, which corresponded to the surface of the nodule in the 3D image. The optimal outline was then transformed back into 3D image space to provide the surface of the nodule. An overlap between nodule regions provided by computer and by the radiologists was employed as a performance metric for evaluating the segmentation method. The database included two Lung Imaging Database Consortium (LIDC) data sets that contained 23 and 86 CT scans, respectively, with 23 and 73 nodules that were 3 mm or larger in diameter. For the two data sets, six and four radiologists manually delineated the outlines of the nodules as reference standards in a performance evaluation for nodule segmentation. The segmentation method was trained on the first and was tested on the second LIDC data sets. The mean overlap values were 66% and 64% for the nodules in the first and second LIDC data sets, respectively, which represented a higher performance level than those of two existing segmentation methods that were also evaluated by use of the LIDC data sets. The segmentation method provided relatively reliable results for pulmonary nodule segmentation and would be useful for lung cancer quantification, detection, and diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Relationship between isotope half-life and prostatic edema for optimal prostate dose coverage in permanent seed implants

The robustness of treatment planning to prostatic edema for three different isotopes ({sup 125}I, {sup 103}Pd, and {sup 131}Cs) is explored using dynamical dose calculations on 25 different clinical prostate cases. The treatment plans were made using the inverse planning by simulated annealing (IPSA) algorithm. The prescription was 144, 127, and 125 Gy for {sup 125}I, {sup 131}Cs, and {sup 103}Pd, respectively. For each isotope, three dose distribution schemes were used to impose different protection levels to the urethra: V{sub 120}=0%, V{sub 150}=0%, and V{sub 150}=30%. Eleven initial edema values were considered ranging from 1.0 (no edema) to 2.0 (100%). The edema was assumed to resolve exponentially with time. The prostate volume, seed positions, and seed activity were dynamically tracked to produce the final dose distribution. Edema decay half-lives of 10, 30, and 50 days were used. A total of 675 dynamical calculations were performed for each initial edema value. For the {sup 125}I isotope, limiting the urethra V{sub 120} to 0% leads to a prostate D{sub 90} under 140 Gy for initial edema values above 1.5. Planning with urethra V{sub 150} at 0% provides a good response to the edema; the prostate D{sub 90} remains higher than 140 Gy for edema values up to 1.8 and a half-life of 30 days or less. For {sup 103}Pd, the prostate D{sub 90} is under 97% of the prescription dose for approximately 66%, 40%, and 30% of edema values for urethra V{sub 120}=0%, V{sub 150}=0%, and V{sub 150}=30%, respectively. Similar behavior is seen for {sup 131}Cs and the center of the prostate becomes 'cold' for almost all edema scenarios. The magnitude of the edema following prostate brachytherapy, as well as the half-life of the isotope used and that of the edema resorption, all have important impacts on the dose distribution. The {sup 125}I isotope with its longer half-life is more robust to prostatic edema. Setting up good planning objectives can provide an adequate compromise between organ doses and robustness. This is even more important since seed misplacements will contribute to further degrade dose coverage.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reconstruction of a time-averaged midposition CT scan for radiotherapy planning of lung cancer patients using deformable registration

Purpose: lower lobe lung tumors move with amplitudes of up to 2 cm due to respiration. To reduce respiration imaging artifacts in planning CT scans, 4D imaging techniques are used. Currently, we use a single (midventilation) frame of the 4D data set for clinical delineation of structures and radiotherapy planning. A single frame, however, often contains artifacts due to breathing irregularities, and is noisier than a conventional CT scan since the exposure per frame is lower. Moreover, the tumor may be displaced from the mean tumor position due to hysteresis. The aim of this work is to develop a framework for the acquisition of a good quality scan representing all scanned anatomy in the mean position by averaging transformed (deformed) CT frames, i.e., canceling out motion. A nonrigid registration method is necessary since motion varies over the lung. Methods and Materials: 4D and inspiration breath-hold (BH) CT scans were acquired for 13 patients. An iterative multiscale motion estimation technique was applied to the 4D CT scan, similar to optical flow but using image phase (gray-value transitions from bright to dark and vice versa) instead. From the (4D) deformation vector field (DVF) derived, the local mean position in the respiratory cycle was computed and the 4D DVF was modified to deform all structures of the original 4D CT scan to this mean position. A 3D midposition (MidP) CT scan was then obtained by (arithmetic or median) averaging of the deformed 4D CT scan. Image registration accuracy, tumor shape deviation with respect to the BH CT scan, and noise were determined to evaluate the image fidelity of the MidP CT scan and the performance of the technique. Results: Accuracy of the used deformable image registration method was comparable to established automated locally rigid registration and to manual landmark registration (average difference to both methods <0.5 mm for all directions) for the tumor region. From visual assessment, the registration was good for the clearly visible features (e.g., tumor and diaphragm). The shape of the tumor, with respect to that of the BH CT scan, was better represented by the MidP reconstructions than any of the 4D CT frames (including MidV; reduction of 'shape differences' was 66%). The MidP scans contained about one-third the noise of individual 4D CT scan frames. Conclusions: We implemented an accurate method to estimate the motion of structures in a 4D CT scan. Subsequently, a novel method to create a midposition CT scan (time-weighted average of the anatomy) for treatment planning with reduced noise and artifacts was introduced. Tumor shape and position in the MidP CT scan represents that of the BH CT scan better than MidV CT scan and, therefore, was found to be appropriate for treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Implementation and characterization of a 320-slice volumetric CT scanner for simulation in radiation oncology

Purpose: Effective target definition and broad employment of treatment response assessment with dynamic contrast-enhanced CT in radiation oncology requires increased speed and coverage for use within a single bolus injection. To this end, a novel volumetric CT scanner (Aquilion One, Toshiba, Tochigi Pref., Japan) has been installed at the Princess Margaret Hospital for implementation into routine CT simulation. This technology offers great advantages for anatomical and functional imaging in both scan speed and coverage. The aim of this work is to investigate the system's imaging performance and quality as well as CT quantification accuracy which is important for radiotherapy dose calculations. Methods: The 320-slice CT scanner uses a 160 mm wide-area (2D) solid-state detector design which provides the possibility to acquire a volumetric axial length of 160 mm without moving the CT couch. This is referred to as ''volume'' and can be scanned with a rotation speed of 0.35-3 s. The scanner can also be used as a 64-slice CT scanner and perform conventional (axial) and helical acquisitions with collimation ranges of 1-32 and 16-32 mm, respectively. Commissioning was performed according to AAPM Reports TG 66 and 39 for both helical and volumetric imaging. Defrise and other cone-beam image analysis tests were performed. Results: Overall, the imaging spatial resolution and geometric efficiency (GE) were found to be very good (>10 lp/mm, <1 mm spatial integrity and GE{sub 160mm}=85%) and within the AAPM guidelines as well as IEC recommendations. Although there is evidence of some cone-beam artifacts when scanning the Defrise phantom, image quality was found to be good and sufficient for treatment planning (soft tissue noise <10 HU). Measurements of CT number stability and contrast-to-noise values across the volume indicate clinically acceptable scan accuracy even at the field edge. Conclusions: Initial experience with this exciting new technology confirms its accuracy for routine CT simulation within radiation oncology and allows for future investigations into specialized dynamic volumetric imaging applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

Virtual monochromatic imaging in dual-source dual-energy CT: Radiation dose and image quality

Purpose: To evaluate the image quality of virtual monochromatic images synthesized from dual-source dual-energy computed tomography (CT) in comparison with conventional polychromatic single-energy CT for the same radiation dose. Methods: In dual-energy CT, besides the material-specific information, one may also synthesize monochromatic images at different energies, which can be used for routine diagnosis similar to conventional polychromatic single-energy images. In this work, the authors assessed whether virtual monochromatic images generated from dual-source CT scanners had an image quality similar to that of polychromatic single-energy images for the same radiation dose. First, the authors provided a theoretical analysis of the optimal monochromatic energy for either the minimum noise level or the highest iodine contrast to noise ratio (CNR) for a given patient size and dose partitioning between the low- and high-energy scans. Second, the authors performed an experimental study on a dual-source CT scanner to evaluate the noise and iodine CNR in monochromatic images. A thoracic phantom with three sizes of attenuating rings was used to represent four adult sizes. For each phantom size, three dose partitionings between the low-energy (80 kV) and the high-energy (140 kV) scans were used in the dual-energy scan. Monochromatic images at eight energies (40 to 110 keV) were generated for each scan. Phantoms were also scanned at each of the four polychromatic single energy (80, 100, 120, and 140 kV) with the same radiation dose. Results: The optimal virtual monochromatic energy depends on several factors: phantom size, partitioning of the radiation dose between low- and high-energy scans, and the image quality metrics to be optimized. With the increase of phantom size, the optimal monochromatic energy increased. With the increased percentage of radiation dose on the low energy scan, the optimal monochromatic energy decreased. When maximizing the iodine CNR in monochromatic images, the optimal energy was lower than that when minimizing noise level. When the total radiation dose was equally distributed between low and high energy in dual-energy scans, for minimum noise, the optimal energies were 68, 71, 74, and 77 keV for small, medium, large, and extra-large (xlarge) phantoms, respectively; for maximum iodine CNR, the optimal energies were 66, 68, 70, 72 keV. With the optimal monochromatic energy, the noise level was similar to and the CNR was better than that in a single-energy scan at 120 kV for the same radiation dose. Compared to an 80 kV scan, however, the iodine CNR in monochromatic images was lower for the small, medium, and large phantoms. Conclusions: In dual-source dual-energy CT, optimal virtual monochromatic energy depends on patient size, dose partitioning, and the image quality metric optimized. With the optimal monochromatic energy, the noise level was similar to and the iodine CNR was better than that in 120 kV images for the same radiation dose. Compared to single-energy 80 kV images, the iodine CNR in virtual monochromatic images was lower for small to large phantom sizes.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quantifying the margin sharpness of lesions on radiological images for content-based image retrieval

Purpose: To develop a method to quantify the margin sharpness of lesions on CT and to evaluate it in simulations and CT scans of liver and lung lesions. Methods: The authors computed two attributes of margin sharpness: the intensity difference between a lesion and its surroundings, and the sharpness of the intensity transition across the lesion boundary. These two attributes were extracted from sigmoid curves fitted along lines automatically drawn orthogonal to the lesion margin. The authors then represented the margin characteristics for each lesion by a feature vector containing histograms of these parameters. The authors created 100 simulated CT scans of lesions over a range of intensity difference and margin sharpness, and used the concordance correlation between the known parameter and the corresponding computed feature as a measure of performance. The authors also evaluated their method in 79 liver lesions (44 patients: 23 M, 21 F, mean age 61) and 58 lung nodules (57 patients: 24 M, 33 F, mean age 66). The methodology presented takes into consideration the boundary of the liver and lung during feature extraction in clinical images to ensure that the margin feature do not get contaminated by anatomy other than the normal organ surrounding the lesions. For evaluation in these clinical images, the authors created subjective independent reference standards for pairwise margin sharpness similarity in the liver and lung cohorts, and compared rank orderings of similarity used using our sharpness feature to that expected from the reference standards using mean normalized discounted cumulative gain (NDCG) over all query images. In addition, the authors compared their proposed feature with two existing techniques for lesion margin characterization using the simulated and clinical datasets. The authors also evaluated the robustness of their features against variations in delineation of the lesion margin by simulating five types of deformations of the lesion margin. Equivalence across deformations was assessed using Schuirmann's paired two one-sided tests. Results: In simulated images, the concordance correlation between measured gradient and actual gradient was 0.994. The mean (s.d.) and standard deviation NDCG score for the retrieval of K images, K = 5, 10, and 15, were 84% (8%), 85% (7%), and 85% (7%) for CT images containing liver lesions, and 82% (7%), 84% (6%), and 85% (4%) for CT images containing lung nodules, respectively. The authors' proposed method outperformed the two existing margin characterization methods in average NDCG scores over all K, by 1.5% and 3% in datasets containing liver lesion, and 4.5% and 5% in datasets containing lung nodules. Equivalence testing showed that the authors' feature is more robust across all margin deformations (p < 0.05) than the two existing methods for margin sharpness characterization in both simulated and clinical datasets. Conclusions: The authors have described a new image feature to quantify the margin sharpness of lesions. It has strong correlation with known margin sharpness in simulated images and in clinical CT images containing liver lesions and lung nodules. This image feature has excellent performance for retrieving images with similar margin characteristics, suggesting potential utility, in conjunction with other lesion features, for content-based image retrieval applications.

60 APPLIED LIFE SCIENCES↗

2D lag and signal nonlinearity correction in an amorphous silicon EPID and their impact on pretreatment dosimetric verification

Purpose: This investigation provides measurements of signal lag and nonlinearity separately for the Varian aS500 electronic portal imaging device (EPID), and an algorithm to correct for these effects in 2D; their potential impact on intensity modulated radiation therapy (IMRT) verification is also investigated. The authors quantify lag, as a function of both delivered monitor units (MU) and time, by using a range of MUs delivered at a clinically used rate of 400 MU/min. Explicit cumulative lag curves are thus determined for a range of MUs and times between the end of irradiation and the end of image acquisition. Signal nonlinearity is also investigated as a function of total MUs delivered. The family of cumulative lag curves and signal nonlinearity are then used to determine their effects on dynamic multileaf collimator (MLC) (IMRT) deliveries, and to correct for theses effects in 2D. Methods: Images acquired with an aS500 EPID and Varis Portal-Vision software were used to quantify detector lag and signal-nonlinearity. For the signal lag investigation, Portal-Vision's service monitor was used to acquire EPID images at a rate of 8 frames/s. The images were acquired during irradiation and 66 s thereafter, by inhibiting the M-holdoff-In signal of the Linac for a range of 4.5-198.5 MUs. Relative cumulative lag was calculated by integrating the EPID signal for a time after beam-off, and normalizing this to the integrated EPID signal accumulated during radiation. Signal nonlinearity was studied by acquiring 10 Multiplication-Sign 10 cm{sup 2} open-field EPID images in 'integrated image' mode for a range of 2-500 MUs, and normalized to the 100 MU case. All data were incorporated into in-house written software to create a 2D correction map for these effects, using the field's MLC file and a field-specific calculated 2D 'time-map,' which keeps track of the time elapsed from the last fluence delivered at each given point in the image to the end of the beam delivery. Results: Relative cumulative lag curves reveal that the lag alone can deviate the EPID's perceived dose by as large as 6% (1 MU delivery, 60 s postirradiation). For signal nonlinearity relative to 100 MU, EPID signals per MU of 0.84 and 1.01 were observed for 2 and 500 MUs, respectively. Correction maps were applied to a 1 cm sweeping-window 14 Multiplication-Sign 14 cm{sup 2} field and clinical head-and-neck IMRT field. A mean correction of 1.028 was implemented in the head-and-neck field, which significantly reduced lag-related asymmetries in the EPID images, and restored linearity to the EPID imager's dose response. Corrections made to the sweeping-field showed good agreement with the treatment planning system-predicted field, yielding an average percent difference of 0.05%{+-} 0.91%, compared to the -1.32%{+-} 1.02% before corrections, or 1.75%{+-} 1.04% when only a signal nonlinearity correction is made. Conclusions: Lag and signal-nonlinearity have been quantified for an aS500 EPID imager, and an effective 2D correction method has been developed which effectively removes nonlinearity and lag effects. Both of these effects were shown to negatively impact IMRT verifications. Especially fields that involve prolonged irradiation and small overall MUs should be corrected for in 2D.

60 APPLIED LIFE SCIENCES↗

Measurement and correction of leaf open times in helical tomotherapy

Purpose: The binary multileaf collimator (MLC) is one of the most important components in helical tomotherapy (HT), as it modulates the dose delivered to the patient. However, methods to ensure MLC quality in HT treatments are lacking. The authors obtained data on the performance of the MLC in treatments administered in their department in order to assess possible delivery errors due to the MLC. Correction methods based on their data are proposed. Methods: Twenty sinograms from treatments delivered using both of the authors HT systems were measured and analyzed by recording the fluence collected by the imaging detector. Planned and actual sinograms were compared using distributions of leaf open time (LOT) errors, as well as differences in fluence reconstructed at each of the 51 projections into which the treatment planning system divides each rotation for optimization purposes. They proposed and applied a method based on individual leaf error correction and the increase in projection time to prevent latency effects when LOT is close to projection time. In order to analyze the dosimetric impact of the corrections, inphantom measurements were made for four corrected treatments. Results: The LOTs measured were consistent with those planned. Most of the mean errors in LOT distributions were within 1 ms with standard deviations of over 4 ms. Reconstructed fluences showed good results, with over 90% of points passing the 3% criterion, except in treatments with a short mean LOT, where the percentage of passing points was as low as 66%. Individual leaf errors were as long as 4 ms in some cases. Corrected sinograms improved error distribution, with standard deviations of over 3 ms and increased percentages of points passing 3% in the fluence per angle analysis, especially in treatments with a short mean LOT and those that were more subject to latency effects. The minimum percentage of points within 3% increased to 86%. In-phantom measurements of the corrected treatments showed that, while treatments affected by latency effects were improved, those affected by individual leaf errors were not. Conclusions: Measurement of MLC performance in real treatments provides the authors with a valuable tool for ensuring the quality of HT delivery. The LOTs of MLC are very accurate in most cases. Sources of error were found and correction methods proposed and applied. The corrections decreased the amount of LOT errors. The dosimetric impact of these corrections should be evaluated more thoroughly using 3D dose distribution analysis.

07 ISOTOPE AND RADIATION SOURCES↗

Tomotherapy treatment plan quality assurance: The impact of applied criteria on passing rate in gamma index method

Purpose: Pretreatment patient plan verification with gamma index (GI) metric analysis is standard procedure for intensity modulated radiation therapy (IMRT) treatment. The aim of this paper is to evaluate the variability of the local and global gamma index obtained during standard pretreatment quality assurance (QA) measurements for plans performed with Tomotherapy unit. The QA measurements were performed with a 3D diode array, using variable passing criteria: 3%/3 mm, 2%/2 mm, 1%/1 mm, each with both local and global normalization.Methods: The authors analyzed the pretreatment QA results for 73 verifications; 37 were prostate cancer plans, 16 were head and neck plans, and 20 were other clinical sites. All plans were treated using the Tomotherapy Hi-Art System. Pretreatment QA plans were performed with the commercially available 3D diode array ArcCHECK™. This device has 1386 diodes arranged in a helical geometry spaced 1 cm apart. The dose measurements were acquired on the ArcCHECK™ and then compared with the calculated dose using the standard gamma analysis method. The gamma passing rate (%GP), defined as the percentage of points satisfying the condition GI < 1, was calculated for different criteria (3%/3 mm, 2%/2 mm, 1%/1 mm) and for both global and local normalization. In the case of local normalization method, the authors set three dose difference threshold (DDT) values of 2, 3, and 5 cGy. Dose difference threshold is defined as the minimum absolute dose error considered in the analysis when using local normalization. Low-dose thresholds (TH) of 5% and 10% were also applied and analyzed.Results: Performing a paired-t-test, the authors determined that the gamma passing rate is independent of the threshold values for all of the adopted criteria (5%TH vs 10%TH, p > 0.1). Our findings showed that mean %GPs for local (or global) normalization for the entire study group were 93% (98%), 84% (92%), and 66% (61%) for 3%/3 mm, 2%/2 mm, and 1%/1 mm criteria, respectively. DDT was equal to 2 cGy for the local normalization analysis cases. The authors observed great variability in the resulting %GP. With 3%/3 mm gamma criteria, the overall passing rate with local normalization was 4.6% less on the average than with global one, as expected. The wide difference between %GP calculated with global or local approach is also confirmed by an unpaired t-test statistical analysis.Conclusions: The variability of %GP obtained confirmed the necessity to establish defined agreement criteria that could be universal and comparable between institutions. In particular, while the gamma passing rate does not depend on the choice of threshold, the choice of DDT strongly influences the gamma passing rate for local calculations. The difference between global and local %GP was statistically significant for prostate and other treatment sites when DDT was changed from 2 to 3 cGy.

61 RADIATION PROTECTION AND DOSIMETRY↗

Self-assessed performance improves statistical fusion of image labels

Purpose: Expert manual labeling is the gold standard for image segmentation, but this process is difficult, time-consuming, and prone to inter-individual differences. While fully automated methods have successfully targeted many anatomies, automated methods have not yet been developed for numerous essential structures (e.g., the internal structure of the spinal cord as seen on magnetic resonance imaging). Collaborative labeling is a new paradigm that offers a robust alternative that may realize both the throughput of automation and the guidance of experts. Yet, distributing manual labeling expertise across individuals and sites introduces potential human factors concerns (e.g., training, software usability) and statistical considerations (e.g., fusion of information, assessment of confidence, bias) that must be further explored. During the labeling process, it is simple to ask raters to self-assess the confidence of their labels, but this is rarely done and has not been previously quantitatively studied. Herein, the authors explore the utility of self-assessment in relation to automated assessment of rater performance in the context of statistical fusion. Methods: The authors conducted a study of 66 volumes manually labeled by 75 minimally trained human raters recruited from the university undergraduate population. Raters were given 15 min of training during which they were shown examples of correct segmentation, and the online segmentation tool was demonstrated. The volumes were labeled 2D slice-wise, and the slices were unordered. A self-assessed quality metric was produced by raters for each slice by marking a confidence bar superimposed on the slice. Volumes produced by both voting and statistical fusion algorithms were compared against a set of expert segmentations of the same volumes. Results: Labels for 8825 distinct slices were obtained. Simple majority voting resulted in statistically poorer performance than voting weighted by self-assessed performance. Statistical fusion resulted in statistically indistinguishable performance from self-assessed weighted voting. The authors developed a new theoretical basis for using self-assessed performance in the framework of statistical fusion and demonstrated that the combined sources of information (both statistical assessment and self-assessment) yielded statistically significant improvement over the methods considered separately. Conclusions: The authors present the first systematic characterization of self-assessed performance in manual labeling. The authors demonstrate that self-assessment and statistical fusion yield similar, but complementary, benefits for label fusion. Finally, the authors present a new theoretical basis for combining self-assessments with statistical label fusion.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Assessment of individual organ doses in a realistic human phantom from neutron and gamma stimulated spectroscopy of the breast and liver

Purpose: Understanding the radiation dose to a patient is essential when considering the use of an ionizing diagnostic imaging test for clinical diagnosis and screening. Using Monte Carlo simulations, the authors estimated the three-dimensional organ-dose distribution from neutron and gamma irradiation of the male liver, female liver, and female breasts for neutron- and gamma-stimulated spectroscopic imaging. Methods: Monte Carlo simulations were developed using the Geant4 GATE application and a voxelized XCAT human phantom. A male and a female whole body XCAT phantom was voxelized into 256 × 256 × 600 voxels (3.125 × 3.125 × 3.125 mm{sup 3}). A monoenergetic rectangular beam of 5.0 MeV neutrons or 7.0 MeV photons was made incident on a 2 cm thick slice of the phantom. The beam was rotated at eight different angles around the phantom ranging from 0° to 180°. Absorbed dose was calculated for each individual organ in the body and dose volume histograms were computed to analyze the absolute and relative doses in each organ. Results: The neutron irradiations of the liver showed the highest organ dose absorption in the liver, with appreciably lower doses in other proximal organs. The dose distribution within the irradiated slice exhibited substantial attenuation with increasing depth along the beam path, attenuating to ∼15% of the maximum value at the beam exit side. The gamma irradiation of the liver imparted the highest organ dose to the stomach wall. The dose distribution from the gammas showed a region of dose buildup at the beam entrance, followed by a relatively uniform dose distribution to all of the deep tissue structures, attenuating to ∼75% of the maximum value at the beam exit side. For the breast scans, both the neutron and gamma irradiation registered maximum organ doses in the breasts, with all other organs receiving less than 1% of the breast dose. Effective doses ranged from 0.22 to 0.37 mSv for the neutron scans and 41 to 66 mSv for the gamma scans. Conclusions: Neutron and gamma irradiation of a primary target organ was found to impart the majority of the total dose to the primary target organ (and other large organs) within the beam plane and considerably lower dose to proximal organs outside of the beam. These results also indicate that despite the use of a highly scattering particle such as a neutron, the dose from neutron stimulated emission computed tomography scans is on par with other clinical imaging techniques such as x-ray computed tomography (x-ray CT). Given the high nonuniformity in the dose across an organ during the neutron scan, care must be taken when computing average doses from neutron irradiations. The effective doses from neutron scanning were found to be comparable to x-ray CT. Further technique modifications are needed to reduce the effective dose levels from the gamma scans.

61 RADIATION PROTECTION AND DOSIMETRY↗