Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “test plan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Collaboration versus communication: The Department of Energy's Amchitka Island and the Aleut Community

Increasingly managers and scientists are recognizing that solving environmental problems requires the inclusion of a wide range of disciplines, governmental agencies, Native American tribes, and other stakeholders. Usually such inclusion involves communication at the problem-formulation phase, and at the end to report findings. This paper examines participatory research, the differences between the traditional stakeholder involvement method of communication (often one-way, at the beginning and the end), compared to full collaboration, where parties are actively involved in the scientific process. Using the Department of Energy's (DOE) Amchitka Island in the Aleutians as a case study, we demonstrate that the inclusion of Aleut people throughout the process resulted in science that was relevant not only to the agency's needs and to the interested and affected parties, but that led to a solution. Amchitka Island was the site of three underground nuclear tests from 1965 to 1971, and virtually no testing of radionuclide levels in biota, subsistence foods, or commercial fish was conducted after the 1970s. When DOE announced plans to close Amchitka, terminating its managerial responsibility, without any further testing of radionuclide levels in biota, there was considerable controversy, which resulted in the development of a Science Plan to assess the potential risks to the marine environment from the tests. The Consortium for Risk Evaluation with Stakeholder Participation (CRESP) was the principle entity that developed and executed the science plan. Unlike traditional science, CRESP embarked on a process to include the Alaskan Natives of the Aleutian Islands (Aleuts), relevant state and federal agencies, and other stakeholders at every phase. Aleuts were included in the problem-formulation, research design refinement, the research, analysis of data, dissemination of research findings, and public communication. This led to agreement with the results, and to developing a path forward (production of a biomonitoring plan designed to provide early warning of any future radionuclide leakage and ecosystem/human health risks). The process outlined was successful in resolving a previously contentious situation by inclusion and collaboration with the Aleuts, among others, and could be usefully applied elsewhere to complex environmental problems where severe data gaps exist.

54 ENVIRONMENTAL SCIENCES↗

SU-E-P-46: Clinical Acceptance Testing and Implementation of a Portable CT Unit

Purpose: Planning for the first installation in New England of a new portable CT unit to be used in the Operating Room required the integration of many departments including Surgery, Neurosurgery, Information Services, Clinical Engineering, Radiology and Medical Physics/Radiation Safety. Acceptance testing and the quality assurance procedures were designed to optimize image quality and patient and personnel radiation exposure. Methods: The vendor’s protocols were tested using the CT Dosimetry phantoms. The system displayed the CTDIw instead of the CTDIvol while testing the unit. Radiation exposure was compared to existing CT scanners from installed CT units throughout the facility. Brainlab measures all 4 periphery slots on the CT Dosimetry phantom. The ACR measures only the superior slot for the periphery measurement. A comprehensive radiation survey was also performed for several locations. Results: The CTDIvol measurements were comparable for the following studies: brain, C-Spine, and sinuses. However, the mobile CT measurements were slightly higher than other CT units but within acceptable tolerance if measured using the ACR method.Based on scatter measurements, it was determined if any personnel were to stay in the OR Suite during image acquisition that the appropriate lead apron and thyroid shields had to be worn.In addition, to reduce unnecessary scatter, there were two mobile 6 foot wide shields (1/16″ lead equivalent) available to protect personnel in the room and adjacent areas. Conclusion: Intraoperative CT provides the physician new opportunities for evaluation of the progression of surgical resections and device placement at the cost of increasing the amount of trained personnel required to perform this procedure. It also brings with it challenges to keep the radiation exposure to the patients and staff within reasonable limits.

60 APPLIED LIFE SCIENCES↗

Evaluation of MatriXX for IMRT and VMAT dose verifications in peripheral dose regions

Purpose: MatriXX is a two-dimensional ion chamber array designed for IMRT/VMAT (RapidArc, IMAT, etc.) dose verifications. Its dosimetric properties have been characterized for megavoltage beams in a number of studies; however, to the best of the authors' knowledge, there is still a lack of an investigation into its performance in the peripheral or low dose regions. In this work, the authors have carried out a systematic study on this issue. Methods: The authors compare the performance of MatriXX with a cylindrical ion chamber in solid water phantoms in the peripheral dose regions. The comparisons are performed for a number of typical irradiation conditions that involve different gantry and/or MLC motions, field sizes, and distances to the target including static gantry/open fields, static gantry/sweeping MLC gap (mimicking an IMRT delivery), dynamic gantry/oscillating sweeping MLC gap (mimicking a VMAT delivery), as well as clinical IMRT and VMAT plans. Results: MatriXX, when used according to the manufacturer's recommendations, is found to disagree with an ion chamber in peripheral dose regions. This disagreement has been attributed to four types of MatriXX errors, namely, positive bias, over-response to scattered doses, round-off error, and angular dependence, all of which contribute to dose inaccuracies in the peripheral regions. The positive bias, which is independent of the dose level, is cumulative when MatriXX operates in the movie mode. The accumulation is proportional to the number of movie frames (snaps) when the sampling time is greater than 500 ms and is proportional to the overall movie time for a sampling time shorter than 500 ms. This behavior suggests multiple sources of the bias. MatriXX is also found to over-respond to peripheral doses by about 2.0% for the regions investigated in this work (3-15 cm from the field edge), where phantom scatter and collimator scatter dominate. Round-off error is determined to be due to insufficient precision in conversion of the raw signals to MatriXX software data for low doses. Angular dependence is defined as the dose response of MatriXX at different gantry angles. Up to 8% difference in detector response has been observed between 0 deg. and 180 deg. Possible sources of these errors are discussed and a correction method is suggested. With corrections, MatriXX shows good agreement with the ion chamber in all cases involving different gantry and/or MLC dynamics, as well as the clinical plans. For both primary and peripheral doses, MatriXX shows dose linearity down to 2 cGy with an accuracy of within 1% of the local dose. Conclusions: The performance of MatriXX has been systematically evaluated in the peripheral dose regions. Major sources of error associated with MatriXX are identified and a correction method is suggested. This method has been successfully tested using both experimental and clinical plans. In all cases, good agreements between MatriXX and an ion chamber are achieved after corrections. The authors conclude that with proper corrections, MatriXX can be reliably used for peripheral dose measurements within the ranges studied.

60 APPLIED LIFE SCIENCES↗

The Integrated Airport: Building a Successful NextGen Testbed

This presentation will describe a unique public-private partnership - the Integrated Airport - that was created to engage in research and testing related to NextGen Technology deployment. NextGen refers to the program that will be initiated to modernize the US National Airspace. As with any major, multi-decade initiative, such as NextGen, integration of work efforts by multiple partners in the modernization is critical for success. This talk will focus on the development of the consortium, how the consortium plans for NextGen initiatives, the series of technology demonstrations we have produced and plans for the future of NextGen testing and implementation.

42 ENGINEERING↗

SU-F-T-469: A Clinically Observed Discrepancy Between Image-Based and Log- Based MLC Position

Purpose: To present a clinical case which challenges the base assumption of log-file based QA, by showing that the actual position of a MLC leaf can suddenly deviate from its programmed and logged position by >1 mm as observed with real-time imaging. Methods: An EPID-based exit-fluence dosimetry system designed to prevent gross delivery errors was used in cine mode to capture portal images during treatment. Visual monitoring identified an anomalous MLC leaf pair gap not otherwise detected by the automatic position verification. The position of the erred leaf was measured on EPID images and log files were analyzed for the treatment in question, the prior day’s treatment, and for daily MLC test patterns acquired on those treatment days. Additional standard test patterns were used to quantify the leaf position. Results: Whereas the log file reported no difference between planned and recorded positions, image-based measurements showed the leaf to be 1.3±0.1 mm medial from the planned position. This offset was confirmed with the test pattern irradiations. Conclusion: It has been clinically observed that log-file derived leaf positions can differ from their actual positions by >1 mm, and therefore cannot be considered to be the actual leaf positions. This cautions the use of log-based methods for MLC or patient quality assurance without independent confirmation of log integrity. Frequent verification of MLC positions through independent means is a necessary precondition to trusting log file records. Intra-treatment EPID imaging provides a method to capture departures from MLC planned positions. Work was supported in part by Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

RETRO RX

RETRO Rx is an R&D 100 Gold Award-winning suite of tools that provides a new class of analytics in the space between traditional epidemiological models and unanalyzed spreadsheets of data. Unlike traditional models, these tools provide analysts, scientists, practitioners, and decision makers a way to easily and effectively do sophisticated analyses using a simple user interface. AIDO guides users at the early stages of a disease outbreak by comparing the current parameters to historic outbreaks. RED Alert constructs a broad historical picture of disease incidence (recent outbreak included) to detect disease reemergence at its earliest stages, locally and globally. RETRO Rx compiles data and presents analysis in a clear, concise visual format to support disease mitigation and prevention planning. Both are available currently as web-based apps. A prototype of the RED Alert mobile app with enhanced functionality is available for beta testing and AIDO mobile app development is planned.

59 BASIC BIOLOGICAL SCIENCES↗

SU-E-T-300: Spatial Variations of Multiple Off-Axial Targets for a Single Isocenter SRS Treatment Plan in ExacTrac 6D Robotic Couch System

Purpose: To evaluate the spatial variations of multiple off-axial targets for a single isocenter stereotactic radiosurgery (SRS) treatment plan in ExacTrac 6D robotic couch system (BrainLab AG). Methods: Five metallic ball bearing (BB) markers were placed sparsely in 3D off-axial locations (non-coplanar) inside a skull phantom as the representatives of multiple targets mimicking multiple brain metastases. The locations of the BB markers were carefully chosen to minimize overlapping of each other in a port imaging detector plane. The skull phantom was immobilized by a frameless mask and CT scanned with a BrainLab Head and Neck Localizer using a GE Optima MDCT scanner. The CT images were exported to iPlan software (BrainLab AG) and a multiple target PTV was drawn by combining all the contours of the BBs. The margin of the MLC opening was selected as 3 mm expansion outward. Two coplanar arc beams were placed to generate a single isocenter SRS plan to treat the PTV. The arc beams were delivered using Novalis Tx system with portal imaging acquisition mode per 10% temporal resolution. The locations of the BBs were visualized and analyzed with respect to the MLC aperture in the treatment plan similar to the Winston-Lutz test. Results: All the BBs were clearly identified inside the MLC openings. The positional errors for the BBs were overall less than 1 mm along the rotational path of the two arcs. Conclusion: This study verified that the spatial deviations of multiple off-axial targets for a single isocenter SRS treatment plan is within sub-millimeter range in ExacTrac 6D robotic couch system. Accompanied with the Winston-Lutz test, this test will quality-assure the spatial accuracies of the isocenter as well as the positions of multiple off-axial targets for the SRS treatment using a single isocenter multiple target treatment plan.

60 APPLIED LIFE SCIENCES↗

Dosimetric and Radiobiologic Comparison of 3D Conformal Versus Intensity Modulated Planning Techniques for Prostate Bed Radiotherapy

Adjuvant radiotherapy for locally advanced prostate cancer improves biochemical and clinical disease-free survival. While comparisons in intact prostate cancer show a benefit for intensity modulated radiation therapy (IMRT) over 3D conformal planning, this has not been studied for post-prostatectomy radiotherapy (RT). This study compares normal tissue and target dosimetry and radiobiological modeling of IMRT vs. 3D conformal planning in the postoperative setting. 3D conformal plans were designed for 15 patients who had been treated with IMRT planning for salvage post-prostatectomy RT. The same computed tomography (CT) and target/normal structure contours, as well as prescription dose, was used for both IMRT and 3D plans. Normal tissue complication probabilities (NTCPs) were calculated based on the dose given to the bladder and rectum by both plans. Dose-volume histogram and NTCP data were compared by paired t-test. Bladder and rectal sparing were improved with IMRT planning compared to 3D conformal planning. The volume of the bladder receiving at least 75% (V75) and 50% (V50) of the dose was significantly reduced by 28% and 17%, respectively (p = 0.002 and 0.037). Rectal dose was similarly reduced, V75 by 33% and V50 by 17% (p = 0.001 and 0.004). While there was no difference in the volume of rectum receiving at least 65 Gy (V65), IMRT planning significant reduced the volume receiving 40 Gy or more (V40, p = 0.009). Bladder V40 and V65 were not significantly different between planning modalities. Despite these dosimetric differences, there was no significant difference in the NTCP for either bladder or rectal injury. IMRT planning reduces the volume of bladder and rectum receiving high doses during post-prostatectomy RT. Because of relatively low doses given to the bladder and rectum, there was no statistically significant improvement in NTCP between the 3D conformal and IMRT plans.

61 RADIATION PROTECTION AND DOSIMETRY↗

AGR-5/6/7 Irradiation Test Predictions using PARFUME

PARFUME, (PARticle FUel ModEl) a fuel performance modeling code used for high temperature gas-cooled reactors (HTGRs), was used to model the Advanced Gas Reactor (AGR)-5/6/7 irradiation test using predicted physics and thermal hydraulics data. The AGR-5/6/7 test consists of the combined fifth, sixth, and seventh planned irradiations of the AGR Fuel Development and Qualification Program. The AGR-5/6/7 test train is a multi-capsule, instrumented experiment that is designed for irradiation in the 133.4-mm diameter north east flux trap (NEFT) position of Advanced Test Reactor (ATR). Each capsule contains compacts filled with uranium oxycarbide (UCO) unaltered fuel particles. This report documents the calculations performed to predict the failure probability of tristructural isotropic (TRISO)-coated fuel particles during the AGR-5/6/7 experiment. In addition, this report documents the calculated source term from the driver fuel. The calculations include modeling of the AGR-5/6/7 irradiation that is scheduled to occur from October 2017 to April 2021 over a total of 13 ATR cycles, including nine normal cycles and four Power Axial Locator Mechanism (PALM) cycle for a total between 500 – 550 effective full power days (EFPD). The irradiation conditions and material properties of the AGR-5/6/7 test predicted zero fuel particle failures in Capsules 1, 2, and 4. Fuel particle failures were predicted in Capsule 3 due to internal particle pressure. These failures were predicted in the highest temperature compacts. Capsule 5 fuel particle failures were due to inner pyrolytic carbon (IPyC) cracking causing localized stresses concentrations in the SiC layer. This capsule predicted the highest particle failures due to the lower irradiation temperature. In addition, shrinkage of the buffer and IPyC layer during irradiation resulted in formation of a buffer-IPyC gap. The two capsules at the two ends of the test train, Capsules 1 and 5 experienced the smallest buffer-IPyC gap formation due to the lower irradiation fluences and temperatures. Capsule 3 experienced the largest buffer-IPyC gap formation of just under 24 µm. The release fraction of fission products Ag, Cs, and Sr silver (Ag), cesium (Cs), and strontium (Sr) vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 3, reaching up to 84.8% for the TRISO fuel particles. The release fraction of the other two fission products, Cs and Sr are much smaller and, in most cases, less than 1%. The notable exception is again in Capsule 3, where the release fraction for Cs and Sr reach up to 9.7% and 19.1%, respectively.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

AGR-5/6/7 Irradiation As Run Predictions Using PARFUME

The PARticle FUel ModEl (PARFUME), a fuel performance modeling code used for high-temperature gas-cooled reactors, was used to model the Advanced Gas Reactor (AGR)-5/6/7 irradiation test using as-run physics and thermal data. The AGR-5/6/7 irradiation test consists of the combined fifth, sixth, and seventh planned irradiations of the AGR Fuel Development and Qualification Program. The AGR-5/6/7 test train is a multi-capsule, instrumented experiment that is designed for irradiation in the 133.4-mm diameter northeast flux trap position of the Advanced Test Reactor (ATR) at Idaho National Laboratory. Each capsule contains compacts filled with uranium oxycarbide unaltered fuel particles. This report documents the calculations performed to predict the failure probability of tristructural isotropic (TRISO)-coated fuel particles during the AGR-5/6/7 experiment. In addition, this report documents the calculated fission product release fraction from the fuel. The calculations include modeling of the AGR 5/6/7 irradiation that occurred from February 2018 to July 2020 over nine ATR cycles, including six normal cycles and three power axial locator mechanism cycles, for a total of approximately 376 effective full power days (EFPD). The irradiation conditions and material properties of the AGR-5/6/7 test predicted zero fuel particle failures in Capsules 1, 3, and 4. Fuel particle failures were predicted in two of the compacts in Capsule 2 and one particle failure is predicted in each one of the compacts in Capsule 5. All compacts that exhibited fuel particle failures predicted by PARFUME were caused by localized stress concentrations in the silicon carbide (SiC) layer caused by cracking in the inner pyrolytic (IPyC) layer. In addition, shrinkage of the buffer and IPyC layer during irradiation resulted in formation of a buffer-IPyC gap. Compacts with a lower irradiation temperature and fluence experienced the smallest buffer-IPyC gap formation. Conversely, higher irradiated temperature compacts with a high fluence experienced the largest buffer-IPyC gap formation. Compact 3-6-3 experienced the largest buffer IPyC gap formation of just under 21.7 µm. The release fraction of fission products silver (Ag), cesium (Cs), and strontium (Sr) vary depending on capsule location and irradiation temperature. The maximum release fraction of Ag occurs in Capsule 3, reaching up to 59.5% for the TRISO fuel particles (compact 3-6-3). The release fraction of the other two fission products, Cs and Sr, are much smaller. A maximum Cs release fraction of 1.1% occurred in compact 3-4-3 and 4.4% for Sr in compact 3-6-3.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Achieving Energy Savings with Highly-Controlled Lighting in an Open-Plan Office

An installation in a Federal building tested the effectiveness of a highly-controlled, workstation-specific lighting retrofit. The study took place in an open-office area with 86 cubicles and low levels of daylight. Each cubicle was illuminated by a direct/indirectpendant luminaire with three 32 watt lamps, two dimmable DALI ballasts, and an occupancy sensor. A centralized control system programmed all three lamps to turn on and off according to occupancy on a workstation-by-workstation basis. Field measurements taken over the course of several monthsdemonstrated 40% lighting energy savings compared to a baseline without advanced controls that conforms to GSA's current retrofit standard. A photometric analysis found that the installation provided higher desktop light levels than the baseline, while an occupant survey found that occupants in general preferred the lighting system to thebaseline.Simple payback is fairly high; projects that can achieve lower installation costs and/or higher energy savings and those in which greenhouse gas reduction and occupant satisfaction are significant priorities provide the ideal setting for workstation-specific lighting retrofits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 44 Dissolved Saltcake Samples

Saltcake core samples collected from Tank 44 in 2006 were dissolved to provide material for HGR measurements applicable to F-Area dissolved saltcake material. Additionally, characterization was performed on the Tank 44 saltcake material. The following are key results from the Tank 44 saltcake characterization. The Tank 44 Upper Saltcake Composite, corresponding to the 171 to 285 inch tank level, contained by mass approximately 69% sodium nitrate, 11% sodium carbonate, 8% sodium nitrite, smaller amounts of other salts and components, and 9% unquantified (which includes water, water of hydration, oxygen/hydrogen content of oxides and hydroxides, and uncertainty). The Tank 44 Lower Saltcake Composite, corresponding to the 76 to 114 inch tank level, contained by mass approximately 49% sodium carbonate, 18% sodium nitrate, smaller amounts of other salts, at least 8% sludge, and 9% unquantified (see above). The dissolved saltcake contained free hydroxide less than quantifiable (<0.01 M) due to the limited quantity of material that could be removed from the Shielded Cells based on the sample radioactivity. Measurement by pH paper provided an approximate pH of 12. The following are key results from the Tank 44 HGR testing. During boiling at 106.7 °C, HGR for Tank 44 dissolved saltcake without added glycolate was 7.2×10 -8 ft 3 h -1 ga l-1 . During boiling at 106.9 °C, HGR for Tank 44 dissolved saltcake with 1000 mg/L of added glycolate was 8.2×10 -8 ft 3 h -1 gal -1 . ∙ For the test without added glycolate, the first several HGR measurements at 70, 85, and 100 °C gave indication of the release of dissolved hydrogen and should not be used to represent the sustained thermolytic HGR for those temperatures. The measurements at boiling are the best representation of thermolysis in this testing. Carbon dioxide was observed at concentrations up to 6 vol% in the flow-system offgas for the test at boiling. ∙ Methane generation was observed at 100 °C and boiling. Methane concentration in the total gas generated during testing remained well below the lower flammability limit for methane in air. The addition of 1000 mg/L of glycolate did not have a significant impact on the hydrogen generation rates measured during this testing. The low hydroxide concentration in the Tank 44 dissolved saltcake likely influenced the relatively low thermolytic HGR and high carbon dioxide release observations in this testing. Based on the observation that methane was generated or released upon heating SRS radioactive Tank 44 waste samples to 100 °C and above, we recommend gaining a greater understanding of the cause and mechanism of its generation. First, the applicable literature should be reviewed to reveal the thermolytic methane generation mechanisms of possible methane generating species in the SRS CSTF. If warranted, a plan should be developed for simulant tests with methylated siloxanes and other applicable compounds in order to gain a better mechanistic understanding of methane generation in the SRS CSTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Investigation of Thermolytic Hydrogen Generation Rate in Tank 44 Dissolved Saltcake Samples

Saltcake core samples collected from Tank 44 in 2006 were dissolved to provide material for HGR measurements applicable to F-Area dissolved saltcake material. Additionally, characterization was performed on the Tank 44 saltcake material. The following are key results from the Tank 44 saltcake characterization. The Tank 44 Upper Saltcake Composite, corresponding to the 171 to 285 inch tank level, contained by mass approximately 69% sodium nitrate, 11% sodium carbonate, 8% sodium nitrite, smaller amounts of other salts and components, and 9% unquantified (which includes water, water of hydration, oxygen/hydrogen content of oxides and hydroxides, and uncertainty). The Tank 44 Lower Saltcake Composite, corresponding to the 76 to 114 inch tank level, contained by mass approximately 49% sodium carbonate, 18% sodium nitrate, smaller amounts of other salts, at least 8% sludge, and 9% unquantified (see above). The dissolved saltcake contained free hydroxide less than quantifiable (<0.01 M) due to the limited quantity of material that could be removed from the Shielded Cells based on the sample radioactivity. Measurement by pH paper provided an approximate pH of 12. The following are key results from the Tank 44 HGR testing. During boiling at 106.7 °C, HGR for Tank 44 dissolved saltcake without added glycolate was 7.2×10 -8 ft 3 h -1 gal -1 . During boiling at 106.9 °C, HGR for Tank 44 dissolved saltcake with 1000 mg/L of added glycolate was 8.2×10 -8 ft 3 h -1 gal -1 . For the test without added glycolate, the first several HGR measurements at 70, 85, and 100 °C gave indication of the release of dissolved hydrogen and should not be used to represent the sustained thermolytic HGR for those temperatures. The measurements at boiling are the best representation of thermolysis in this testing. Carbon dioxide was observed at concentrations up to 6 vol% in the flow-system offgas for the test at boiling. Methane generation was observed at 100 °C and boiling. Methane concentration in the total gas generated during testing remained well below the lower flammability limit for methane in air. The addition of 1000 mg/L of glycolate did not have a significant impact on the hydrogen generation rates measured during this testing. The low hydroxide concentration in the Tank 44 dissolved saltcake likely influenced the relatively low thermolytic HGR and high carbon dioxide release observations in this testing. Based on the observation that methane was generated or released upon heating SRS radioactive Tank 44 waste samples to 100 °C and above, we recommend gaining a greater understanding of the cause and mechanism of its generation. First, the applicable literature should be reviewed to reveal the thermolytic methane generation mechanisms of possible methane generating species in the SRS CSTF. If warranted, a plan should be developed for simulant tests with methylated siloxanes and other applicable compounds in order to gain a better mechanistic understanding of methane generation in the SRS CSTF.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Report Initial Work on Developing Plasma Modeling Capability in WARP for NDCX Experiments

This milestone has been accomplished. The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL) has developed and implemented an initial beam-in-plasma implicit modeling capability in Warp; has carried out tests validating the behavior of the models employed; has compared the results of electrostatic and electromagnetic models when applied to beam expansion in an NDCX-I relevant regime; has compared Warp and LSP results on a problem relevant to NDCX-I; has modeled wave excitation by a rigid beam propagating through plasma; and has implemented and begun testing a more advanced implicit method that correctly captures electron drift motion even when timesteps too large to resolve the electron gyro-period are employed. The HIFS-VNL is well on its way toward having a state-of-the-art source-to-target simulation capability that will enable more effective support of ongoing experiments in the NDCX series and allow more confident planning for future ones.

43 PARTICLE ACCELERATORS↗

Heavy Ion Fusion Science Virtual National Laboratory1st Quarter FY08 Milestone Report: Report Initial Work on Developing Plasma Modeling Capability in WARP for NDCX ExperimentsReport Initial work on developing Plasma Modeling Capability in WARP for NDCX Experiments

This milestone has been accomplished. The Heavy Ion Fusion Science Virtual National Laboratory (HIFS-VNL) has developed and implemented an initial beam-in-plasma implicit modeling capability in Warp; has carried out tests validating the behavior of the models employed; has compared the results of electrostatic and electromagnetic models when applied to beam expansion in an NDCX-I relevant regime; has compared Warp and LSP results on a problem relevant to NDCX-I; has modeled wave excitation by a rigid beam propagating through plasma; and has implemented and begun testing a more advanced implicit method that correctly captures electron drift motion even when timesteps too large to resolve the electron gyro-period are employed. The HIFS-VNL is well on its way toward having a state-of-the-art source-to-target simulation capability that will enable more effective support of ongoing experiments in the NDCX series and allow more confident planning for future ones.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Preliminary structural design conceptualization for composite rotor for verdant power water current turbine

Sandia National Laboratories (SNL) and Verdant Power Inc. (VPI) have partnered under a Cooperative Research and Development Agreement (CRADA) to develop a new kinetic hydropower rotor. The rotor features an improved hydrodynamic and structural design which features state-of-the-art technology developed for the wind industry. The new rotor will have higher energy capture, increased system reliability, and reduction of overall cost of energy. This project was divided into six tasks: (1) Composite Rotor Project Planning and Design Specification; (2) Baseline Fatigue Testing and Failure analysis; (3) Develop Blade/Rotor Performance Model; (4) Hydrofoil Survey and Selection; (5) FEM Structural Design; and (6) Develop Candidate Rotor Designs and Prepare Final Report.

13 HYDRO ENERGY↗

SU-E-T-551: PTV Is the Worst-Case of CTV in Photon Therapy

Purpose: To examine the supposition of the static dose cloud and adequacy of the planning target volume (PTV) dose distribution as the worst-case representation of clinical target volume (CTV) dose distribution for photon therapy in head and neck (H and N) plans. Methods: Five diverse H and N plans clinically delivered at our institution were selected. Isocenter for each plan was shifted positively and negatively in the three cardinal directions by a displacement equal to the PTV expansion on the CTV (3 mm) for a total of six shifted plans per original plan. The perturbed plan dose was recalculated in Eclipse (AAA v11.0.30) using the same, fixed fluence map as the original plan. The dose distributions for all plans were exported from the treatment planning system to determine the worst-case CTV dose distributions for each nominal plan. Two worst-case distributions, cold and hot, were defined by selecting the minimum or maximum dose per voxel from all the perturbed plans. The resulting dose volume histograms (DVH) were examined to evaluate the worst-case CTV and nominal PTV dose distributions. Results: Inspection demonstrates that the CTV DVH in the nominal dose distribution is indeed bounded by the CTV DVHs in the worst-case dose distributions. Furthermore, comparison of the D95% for the worst-case (cold) CTV and nominal PTV distributions by Pearson's chi-square test shows excellent agreement for all plans. Conclusion: The assumption that the nominal dose distribution for PTV represents the worst-case dose distribution for CTV appears valid for the five plans under examination. Although the worst-case dose distributions are unphysical since the dose per voxel is chosen independently, the cold worst-case distribution serves as a lower bound for the worst-case possible CTV coverage. Minor discrepancies between the nominal PTV dose distribution and worst-case CTV dose distribution are expected since the dose cloud is not strictly static. This research was supported by the NCI through grant K25CA168984, by The Lawrence W. and Marilyn W. Matteson Fund for Cancer Research, and by the Fraternal Order of Eagles Cancer Research Fund, the Career Development Award Program at Mayo Clinic.

60 APPLIED LIFE SCIENCES↗

Development and Test of Collaring Methods for Nb$_3$SN Quadrupole Magnets

Fermilab is developing Nb 3 Sn quadrupole magnets for the planned upgrade of interaction regions of the Large Hadron Collider (LHC). Two distinctly different approaches have been employed, one using quadrupole‐symmetric and one using dipole‐symmetric collar laminations. This paper describes the design features of both collar types, collaring techniques for brittle Nb 3 Sn coils, and compares the advantages and disadvantages of the two approaches. Results of mechanical analysis for quadrupoles based on dipole‐type and quadrupole‐type collars are presented. Magnet construction issues and test results are reported. Test results include coil and component strain measurements during construction. Plans for the completion and test of the first dipole‐symmetric assembly are described.

Bossert, R.↗