Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “shallow”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

TU-E-201-01: Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionists

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

TU-E-201-02: Eye Lens Dosimetry From CT Perfusion Studies

Madan M. Rehani, Massachusetts General Hospital and Harvard Medical School, Boston Methods for Eye Lens Dosimetry and Studies On Lens Opacities with Interventionalists Radiation induced cataract is a major threat among staff working in interventional suites. Nearly 16 million interventional procedures are performed annually in USA. Recent studies by the principal investigator’s group, primarily among interventional cardiologists, on behalf of the International Atomic Energy Agency, show posterior subcapsular (PSC) changes in the eye lens in 38–53% of main operators and 21–45% of support staff. These changes have potential to lead to cataract in future years, as per information from A-Bomb survivors. The International Commission on Radiological Protection has reduced dose limit for staff by a factor of 7.5 (from 150 mSv/y to 20 mSv/y). With increasing emphasis on radiation induced cataracts and reduction in threshold dose for eye lens, there is a need to implement strategies for estimating eye lens dose. Unfortunately eye lens dosimetry is at infancy when it comes to routine application. Various approaches are being tried namely direct measurement using active or passive dosimeters kept close to eyes, retrospective estimations and lastly correlating patient dose in interventional procedures with staff eye dose. The talk will review all approaches available and ongoing active research in this area, as well as data from surveys done in Europe on status of eye dose monitoring in interventional radiology and nuclear medicine. The talk will provide update on how good is Hp(10) against Hp(3), estimations from CTDI values, Monte Carlo based simulations and current status of eye lens dosimetry in USA and Europe. The cataract risk among patients is in CT examinations of the head. Since radiation induced cataract predominantly occurs in posterior sub-capsular (PSC) region and is thus distinguishable from age or drug related cataracts and is also preventable, actions on awareness can lead to avoidance or even prevention. Learning Objectives: To understand recent changes in eye lens dose limits and thresholds for tissue reactions To understand different approaches to dose estimation for eye lens To learn about challenges in eye lens opacities among staff in interventional fluoroscopy Di Zhang, Toshiba America Medical Systems, Tustin, CA, USA Eye lens radiation dose from brain perfusion CT exams CT perfusion imaging requires repeatedly exposing one location of the head to monitor the uptake and washout of iodinated contrast. The accumulated radiation dose to the eye lens can be high, leading to concerns about potential radiation injury from these scans. CTDIvol assumes continuous z coverage and can overestimate eye lens dose in CT perfusion scans where the table do not increment. The radiation dose to the eye lens from clinical CT brain perfusion studies can be estimated using Monte Carlo simulation methods on voxelized patient models. MDCT scanners from four major manufacturers were simulated and the eye lens doses were estimated using the AAPM posted clinical protocols. They were also compared to CTDIvol values to evaluate the overestimation from CTDIvol. The efficacy of eye lens dose reduction techniques such as tilting the gantry and moving the scan location away from the eyelens were also investigated. Eye lens dose ranged from 81 mGy to 279 mGy, depending on the scanner and protocol used. It is between 59% and 63% of the CTDIvol values reported by the scanners. The eye lens dose is significantly reduced when the eye lenses were not directly irradiated. CTDIvol should not be interpreted as patient dose; this study has shown it to overestimate dose to the eye lens. These results may be used to provide more accurate estimates of actual dose to ensure that protocols are operated safely below thresholds. Tilting the gantry or moving the scanning region further away from the eyes are effective for reducing lens dose in clinical practice. These actions should be considered when they are consistent with the clinical task and patient anatomy. Learning Objectives: To become familiar with method of eye dose estimation for patient in specific situation of brain perfusion CT To become familiar with level of eye lens radiation doses in patients undergoing brain perfusion MDCT To understand methods for reducing eye lens dose to patient Jong Min Park, Department of Radiation Oncology, Seoul National University Hospital, Seoul, Korea Eye lens dosimetry in radiotherapy using contact lens-shaped applicator Dose calculation accuracy of commercial treatment planning systems is relatively low at shallow depths. Therefore, in-vivo measurements are often performed in the clinic to verify delivered doses to eye lens which are located at shallow depth. Current in-vivo dosimetry for eye lens during radiotherapy is generally performed with small in-vivo dosimeters on the surface of patient eyelid. Since this procedure potentially contains considerable uncertainty, a contact lens-shaped applicator made of acrylic (lens applicator) was developed for in-vivo measurements of eye lens dose during radiotherapy to reduce uncertainty. The lens applicator allows the insertion of commercially available metal oxide semiconductor field effect transistor (MOSFET) dosimeters. Computed tomography (CT) images of an anthropomorphic phantom with and without the lens applicator were acquired. A total of 20 VMAT plans were delivered to an anthropomorphic phantom and the doses with the lens applicator and the doses at the surface of the eyelid were measured using both micro and standard MOSFET dosimeters. The differences in measured dose at the surface of the eyelid from the calculated lens dose were acquired. The differences between the measured and the calculated doses at the lens applicator, as well as the differences between the measured and the calculated doses at the surface of the eyelid were acquired. The statistical significance of the differences was analyzed. The average difference between the measured and the calculated dose with the lens applicator was 16.8 % ± 10.4 % with a micro MOSFET dosimeter and 16.6 % ± 10.9% with a standard MOSFET dosimeter. The average difference without the lens applicator was 35.9% ± 41.5% with micro MOSFET dosimeter and 42.9% ± 52.2% with standard MOSFET dosimeter. The maximum difference with micro MOSFET dosimeter was 46% with the applicator and 188.4% without the applicator. For the standard MOSFET dosimeter, the maximum difference was 44.4% with the applicator and 246.4% without the applicator. The lens applicator allowed reduction of the differences between the calculated and the measured dose during in-vivo measurement for the eye lens as compared to in-vivo measurement at the surface of the eyelid. Learning Objectives: To understand limitations of dose calculation with commercial treatment planning system for eye lens during radiotherapy To learn about current in-vivo dosimetry methods for eye lens in the clinic To understand limitations of in-vivo dosimetry for eye lens during radiotherapy Di Zhang is an employee of Toshiba America Medical Systems.

60 APPLIED LIFE SCIENCES↗

WE-G-BRD-01: A Data-Driven 4D-MRI Motion Model to Estimate Full Field-Of-View Abdominal Motion From 2D Image Navigators During MR-Linac Treatment

Purpose: To estimate full field-of-view abdominal respiratory motion from fast 2D image navigators using a 4D-MRI based motion model. This will allow for radiation dose accumulation mapping during MR-Linac treatment. Methods: Experiments were conducted on a Philips Ingenia 1.5T MRI. First, a retrospectively ordered 4D-MRI was constructed using 3D transient-bSSFP with radial in-plane sampling. Motion fields were calculated through 3D non-rigid registration. From these motion fields a PCA-based abdominal motion model was constructed and used to warp a 3D reference volume to fast 2D cine-MR image navigators that can be used for real-time tracking. To test this procedure, a time-series consisting of two interleaved orthogonal slices (sagittal and coronal), positioned on the pancreas or kidneys, were acquired for 1m38s (dynamic scan-time=0.196ms), during normal, shallow, or deep breathing. The coronal slices were used to update the optimal weights for the first two PCA components, in order to warp the 3D reference image and construct a dynamic 4D-MRI time-series. The interleaved sagittal slices served as an independent measure to test the model’s accuracy and fit. Spatial maps of the root-mean-squared error (RMSE) and histograms of the motion differences within the pancreas and kidneys were used to evaluate the method. Results: Cranio-caudal motion was accurately calculated within the pancreas using the model for normal and shallow breathing with an RMSE of 1.6mm and 1.5mm and a histogram median and standard deviation below 0.2 and 1.7mm, respectively. For deep-breathing an underestimation of the inhale amplitude was observed (RMSE=4.1mm). Respiratory-induced antero-posterior and lateral motion were correctly mapped (RMSE=0.6/0.5mm). Kidney motion demonstrated good motion estimation with RMSE-values of 0.95 and 2.4mm for the right and left kidney, respectively. Conclusion: We have demonstrated a method that can calculate dynamic 3D abdominal motion in a large volume, while acquiring real-time cine-MR images for MR-guided radiotherapy.

60 APPLIED LIFE SCIENCES↗

A patient-specific aperture system with an energy absorber for spot scanning proton beams: Verification for clinical application

Purpose: In the authors’ proton therapy system, the patient-specific aperture can be attached to the nozzle of spot scanning beams to shape an irradiation field and reduce lateral fall-off. The authors herein verified this system for clinical application. Methods: The authors prepared four types of patient-specific aperture systems equipped with an energy absorber to irradiate shallow regions less than 4 g/cm{sup 2}. The aperture was made of 3-cm-thick brass and the maximum water equivalent penetration to be used with this system was estimated to be 15 g/cm{sup 2}. The authors measured in-air lateral profiles at the isocenter plane and integral depth doses with the energy absorber. All input data were obtained by the Monte Carlo calculation, and its parameters were tuned to reproduce measurements. The fluence of single spots in water was modeled as a triple Gaussian function and the dose distribution was calculated using a fluence dose model. The authors compared in-air and in-water lateral profiles and depth doses between calculations and measurements for various apertures of square, half, and U-shaped fields. The absolute doses and dose distributions with the aperture were then validated by patient-specific quality assurance. Measured data were obtained by various chambers and a 2D ion chamber detector array. Results: The patient-specific aperture reduced the penumbra from 30% to 70%, for example, from 34.0 to 23.6 mm and 18.8 to 5.6 mm. The calculated field width for square-shaped apertures agreed with measurements within 1 mm. Regarding patient-specific aperture plans, calculated and measured doses agreed within −0.06% ± 0.63% (mean ± SD) and 97.1% points passed the 2%-dose/2 mm-distance criteria of the γ-index on average. Conclusions: The patient-specific aperture system improved dose distributions, particularly in shallow-region plans.

60 APPLIED LIFE SCIENCES↗

SU-G-201-12: Investigation of Beta-Emitter 90Sr-90Y Dose Distribution Using Gafchromic EBT3 Film for Application On Conformal Skin Brachytherapy Device

Purpose: To investigate {sup 90}Sr-{sup 90}Y as a high dose rate (HDR) source for application in a conformal skin brachytherapy (CSBT) device. The CSBT device has been previously developed to provide patient specific treatment for small inoperable lesions and irregular surfaces. Methods: A popular beta emitter, {sup 90}Sr-{sup 90}Y was tested for feasibility in a CSBT device. A 1 cm diameter plaque was used to deliver dose to a solid water phantom containing EBT3 Gafchromic films arranged at the surface and perpendicular to it. Additionally, a 1 cm diameter 6 MeV electron beam was used to irradiate EBT3 film at 100 cm SSD with a 0.5 cm bolus. Films were digitized with an Epson Expression 10000 XL scanner and calibrated with a 6 MeV electron specific dose curve. Normalized percent depth doses (PDD) and dose profiles for both techniques were analyzed using ImageJ. Results: Dose distributions achieved with the {sup 90}Sr-{sup 90}Y sources were compared with those of external electron beam radiation therapy (EBRT). Penumbra (20%- 80%) for EBRT and 90Sr-90Y were 4.3 mm and 1.6 mm, respectively. PDD values of 50% (normalized to 2 mm) were 10.1 mm and 2.8 mm for electron and {sup 90}Sr-{sup 90}Y, respectively. Flatness (80% of the central beam profile) was 14.1% at a 5 mm depth for EBRT and 4.0% at surface for the {sup 90}Sr-{sup 90}Y. Conclusion: As expected, the PDDs of {sup 90}Sr-{sup 90}Y in water are shallower than that of external electron beams for the same field size. {sup 90}Sr-{sup 90}Y can be used in CSBT to provide patient specific treatment where shallower depth doses than that provided by electron external beams may be required: e.g. eyelids, nose, lips, ears, etc. The customizability of EBRT could be replicated by using multiple adjacent {sup 90}Sr-{sup 90}Y plaque placements.

61 RADIATION PROTECTION AND DOSIMETRY↗

Climbing the crustal ladder: Magma storage-depth evolution during a volcanic flare-up

Very large eruptions (>50 km 3 ) and supereruptions (>450 km 3 ) reveal Earth’s capacity to produce and store enormous quantities (>1000 km 3 ) of crystal-poor, eruptible magma in the shallow crust. We explore the interplay between crustal evolution and volcanism during a volcanic flare-up in the Taupo Volcanic Zone (TVZ, New Zealand) using a combination of quartz-feldspar-melt equilibration pressures and time scales of quartz crystallization. Over the course of the flare-up, crystallization depths became progressively shallower, showing the gradual conditioning of the crust. Yet, quartz crystallization times were invariably very short (<100 years), demonstrating that very large reservoirs of eruptible magma were transient crustal features. We conclude that the dynamic nature of the TVZ crust favored magma eruption over storage. Episodic tapping of eruptible magmas likely prevented a supereruption. Instead, multiple very large bodies of eruptible magma were assembled and erupted in decadal time scales.

58 GEOSCIENCES↗

Slow slip source characterized by lithological and geometric heterogeneity

Slow slip events (SSEs) accommodate a significant proportion of tectonic plate motion at subduction zones, yet little is known about the faults that actually host them. The shallow depth (<2 km) of well-documented SSEs at the Hikurangi subduction zone offshore New Zealand offers a unique opportunity to link geophysical imaging of the subduction zone with direct access to incoming material that represents the megathrust fault rocks hosting slow slip. Two recent International Ocean Discovery Program Expeditions sampled this incoming material before it is entrained immediately down-dip along the shallow plate interface. Drilling results, tied to regional seismic reflection images, reveal heterogeneous lithologies with highly variable physical properties entering the SSE source region. These observations suggest that SSEs and associated slow earthquake phenomena are promoted by lithological, mechanical, and frictional heterogeneity within the fault zone, enhanced by geometric complexity associated with subduction of rough crust.

58 GEOSCIENCES↗

Tracking the spatial and temporal links between late Cenozoic extension and magmatism in the Death Valley region (California, USA)

The relationship between late Cenozoic magmatism and extension in the central Basin and Range province (western United States) is complex, necessitating high-precision geochronology to understand its spatiotemporal connections. In the Death Valley region (California), the lack of high-precision U-Pb zircon ages has limited our understanding of the timing of pluton formation and its links to regional extension. We present new high-precision chemical abrasion-isotope dilution-thermal ionization mass spectrometry 206 Pb/ 238 U zircon ages and trace element analyses for eight Death Valley plutons. Our findings reveal three distinct phases of intrusive magmatism: (1) emplacement of shallow rapakivi granites at 13.2 Ma, (2) construction of the mid-crustal Black Mountains intrusive complex at 11.3 Ma, and (3) late emplacement of shallow, compositionally diverse intrusions at 8.2 Ma. A gap in zircon crystallization between 10 Ma and 8.2 Ma coincides with exhumation of the Black Mountains and a transition from sill to dike emplacement. The dominance of rapakivi granites in the Death Valley region, which is rare among Cenozoic granitoids, is likely a result of rapid crustal extension that induces adiabatic decompression. A comparison of the timing of volcanism, plutonism, and tectonic events in Death Valley reveals that intrusive magmatism closely tracks the locus of extension, underscoring the plutonic record as a vital link for understanding regional tectonics and changes in plate boundary dynamics during this period.

58 GEOSCIENCES↗

Cascade theory of electron capture in quantum wells

A cascade theory of electron capture in shallow quantum wells, when the capture process is determined by the interaction with acoustic phonons, is constructed. In these conditions, the ejection of electrons falling into a well back to the conduction band is significant. The possibility of electron ejection is taken into account by introducing an sticking probability for electrons located in the well. Such an approach is analogous to the Lax cascade theory of electron capture at small impurity centers. Calculations have been performed for wells 3 and 4 nm in width in the Al{sub 0.05}Ga{sub 0.95}As/GaAs/Al{sub 0.05}Ga{sub 0.95}As heterostructure. The developed theory has also made it possible to describe thermal ejection of electrons from shallow quantum wells.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Effect of iodine impurity on relaxation of photoexcited silver chloride

The time and temperature dependences of relaxation of excited AgCl and AgCl:I crystals is studied by the method of photostimulated flash of luminescence. The presence of iodine impurity in silver chloride gives rise to hole recombination (luminescence) centers and hole traps in the band gap. It is shown that the main contribution to the decrease in the concentration of electrons localized at deep traps is made by the recombination of electrons with holes released thermally from shallow localization levels (iodine-related centers). Estimation of activation energy for the relaxation process showed that these energies for the AgCl and AgCl:I samples under study are the same within the experimental error and are equal to E{sub rel1} = 0.01 {+-} 0.0005 eV for the initial stage of relaxation and E{sub rel2} = 0.09 {+-} 0.005 eV for the final state. This fact indicates that the majority of hole traps involved in the relaxation process in AgCl are related to iodine impurity. In the course of thermal relaxation in AgCl, relocalization of nonequilibrium charge carriers from shallow levels to deep levels is observed. The depth of the corresponding trap is E{sub arl} = 0.174 {+-} 0.03 eV.

36 MATERIALS SCIENCE↗

Infrared luminescence from silicon nanostructures heavily doped with boron

Intense highly polarized radiation from silicon nanostructures heavily doped with boron to 5 Multiplication-Sign 10{sup 21} cm{sup -3} is studied as a function of temperature, forward current, and an additional lateral electric field. The features of the radiation intensity and degree of polarization suggest that an important role in the formation of the luminescence spectra is played by the ordered system of B{sup +}-B{sup -} dipoles, formed as a result of the reconstruction of shallow boron acceptors as centers with negative correlation energy. The results obtained are interpreted within a proposed model based on two-electron adiabatic potentials, according to which radiation results from donor-acceptor recombination via boron dipole center states, involving shallow phosphorus donors.

36 MATERIALS SCIENCE↗

Enhancing trap and fault seal analyses by integrating observations from HR3D seismic data with well logs and conventional 3D seismic data, Texas inner shelf

An understanding of trap and fault seal quality is critical for assessing hydrocarbon prospectivity. To achieve this, modern analytical techniques leverage well data and conventional industry-standard 3D seismic data to evaluate the trap, and any faults displacing the reservoir and top seal intervals. Above all, geological interpretation provides the framework of trap and fault seal analyses, but can be hindered by the data resolution, quality and acquisition style of the conventional seismic data. Furthermore, limiting the analysis to only the petroleum system at depth may lead to erroneous perceptions because interpreting overburden features, such as shallow faults or gas chimneys, can provide valuable observations with respect to container performance, and can to help validate trap and fault seal predictions. Here, a supplement to conventional 3D data are high-resolution 3D seismic (HR3D) data, which provide detailed images of the overburden geology. This study utilizes an HR3D seismic volume in the San Luis Pass area of the Texas inner shelf, where shallow fault tips and a sizeable gas chimney are interpreted over an unsuccessful hydrocarbon prospect. Static post-drill fault seal and trap analyses suggest that the primary fault displacing the structural closure could have withheld columns of gas c. 100 m high, but disagree with our HR3D seismic interpretations and dry-well analyses. From our results, we hypothesize that tertiary gas migration through fault conduits reduced the hydrocarbon column in the prospective Early Miocene reservoir, and may have resulted from continued movement along the intersecting faults. Overall, this study reinforces the importance of understanding the overburden geology and geohistory of faulted prospects, and demonstrates the utility of pre-drill HR3D acquisition when conducting trap and fault seal analyses.

3D seismic↗

Performance Evaluation of a Two-Dimensional Flood Model on Heterogeneous High-Performance Computing Architectures

This paper describes the implementation of a two-dimensional hydrodynamic flood model with two different numerical schemes on heterogeneous high-performance computing architectures. Both schemes were able to solve the nonlinear hyperbolic shallow water equations using an explicit upwind first-order approach on finite differences and finite volumes, respectively, and were conducted using MPI and CUDA. Four different test cases were simulated on the Summit supercomputer at Oak Ridge National Laboratory. Both numerical schemes scaled up to 128 nodes (768 GPUs) with a maximum 98.2x speedup of over 1 GPU. The lowest run time for the 10 day Hurricane Harvey event simulation at 5 meter resolution (272 million grid cells) was 50 minutes. GPUDirect communication proved to be more convenient than the standard communication strategy. Both strong and weak scaling are shown.

Sharif, Md Bulbul↗

A comparison of Nannochloropsis salina growth performance in two outdoor pond designs: conventional raceways versus the ARID pond with superior temperature management

The present study examines how climatic conditions and pond design affect the growth performance of microalgae. From January to April of 2011, outdoor batch cultures of Nannochloropsis salina were grown in three replicate 780 L conventional raceways, as well as in an experimental 7500 L ARID (Algae Raceway Integrated Design) pond. The ARID culture system utilizes a series of 8 to 20 cm deep basins and a 1.5 m deep canal to enhance light exposure and mitigate temperature variations and extremes. The ARID culture reached the stationary phase 27 days earlier than the conventional raceways, which can be attributed to its superior temperature management and shallower basins. On a night when the air temperature dropped to -9 °C, the water temperature was 18 °C higher in the ARID pond than in the conventional raceways. Lipid and fatty acid content ranged from 16 - 25 % and 5 - 15 %, respectively, as a percentage of AFDW. Palmitic, palmitoleic, and eicosapentaenoic acid comprised the majority of fatty acids. While the ARID culture system achieved nearly double the volumetric productivity relative to the conventional raceways (0.023 vs 0.013 g L-1day-1), areal biomass productivities were of similar magnitude in both pond systems (3.34 vs. 3.47 g m-2day-1), suggesting that the ARID pond design has to be further optimized, most likely by increasing the culture depth or operating at higher cell densities while maintaining adequate mixing.

Crowe, Braden J↗

Numerical Modeling of CO 2 and Brine Leakage through Open Fracture in a Fault Zone: Open Channel Flow or Darcy Flow

Understanding fluids migration and leakage risk along the fault zone is necessary to guarantee the safety of CO 2 geological storage. The validity of Darcy’s law gets challenged in dealing with the flow in open fractures since the occurring of turbulence flow. In this study, we develop a 2D model with usage of T2Well, an integrated wellbore-reservoir simulator, to investigate the leakage problem along open fractures which are embedded in a fault zone from the deep injection reservoir to shallow aquifers. The results record a positive feedback of gas expansion and pressure response in fracture, which causes a quick downward propagation of highly gas saturated zone from the top of fracture and an easy gas breakthrough in the shallower aquifers. The decreasing of aperture size of fracture significantly enhances the leakage rates in fracture, but with less influences as aperture increases. In comparison, the Equivalent Porous Media models show a good approximation with the momentum model of large apertures but poor for the small one. Nevertheless, the differences are small in terms of final CO 2 distribution among various aquifers, suggesting that Darcy’s law may be still “effective” in solving flow problem along fractures in a constant injection system at a large time scale.

58 GEOSCIENCES↗

Mine Flooding History of a Regional Below-Drainage Coalfield Dominated by Barrier Leakage (1970–2014)

A 44-year record of water level fluctuations in a series of adjacent closed underground mines documents the history of closure and mine flooding in the Fairmont Coalfield, one of the oldest coal mining districts in the Pittsburgh coal basin, West Virginia, USA. As closures proceeded and mines began to flood, US environmental regulations were first enacted mandating mine water control and treatment, rendering uncontrolled surface discharges unacceptable. The purpose of this study is to present this flooding history and to identify critical events that determined how mine pools evolved in this case. Also examined is the strategy developed to control and treat water from these mines. Flooding is visualized using both water level hydrographs and mine flooding maps with the latter constructed assuming mine water hydraulic continuity between one or more mines. The earliest flooding formed small pools within near-surface mines closed prior to 1962 yet still pumped following closure to minimize leaking into adjacent still-active workings. These subpools gradually enlarged and merged as more closures occurred and the need for protective pumping was removed, forming what is today referred to as the unconfined Fairmont Pool. Later, deeper mines, separated by intact updip barriers from the Fairmont Pool, were closed and flooded more gradually, supplied in large part by leakage from the Fairmont Pool. By 1985, all mines except 2 had closed and by 1994 all had fully flooded, with the Fairmont Pool interconnected to deeper single mine pools via barrier leakage. As protective pumping ceased, the Fairmont Pool rose to a water level 3 m higher than surface drainage elevation and in 1997 discharged from an undermined section of Buffalo Creek near the Monongahela River. The principal mine operator in the basin then designed a pumping system to transfer water from the Fairmont Pool to their existing treatment facilities to the north, thus terminating the discharge. It may be concluded that the progress of mine flooding was influenced by mining history and design, by the timing of closures, by barrier leakage conditions, and by geologic structure. A key element in how flooding proceeded was the presence of a series of intact barriers separating deep from shallow mines. The shallow mines closed and flooded early, but then lost sufficient water by barrier leakage into the deeper mines to delay the completion of flooding until after the deep mines had all closed and flooded as well. Intensive mine water control has continued from the 1997 breakout to the present. The final water control scheme was likely unanticipated and serendipitous; future district-wide mining efforts should be advised to consider in advance closeout strategies to control mine water postmining.

Donovan, Joseph J.↗

Domain-decomposition nonlinear manifold reduced order model

This software combines nonlinear-manifold reduced order models (NM-ROMs) with domain decomposition (DD) techniques. NM-ROMs, which utilize a shallow, sparse autoencoder trained with full order model (FOM) snapshot data, approximate the FOM state on a nonlinear manifold. These models offer advantages over linear-subspace ROMs (LS-ROMs) particularly in scenarios with slowly decaying Kolmogorov n-width. However, the training of NM-ROMs involves a number of parameters that scale with the size of the FOM, and storing high-dimensional FOM snapshots can significantly increase the cost of ROM training for extreme-scale problems. To mitigate these costs, the software employs DD to partition the FOM into smaller subdomains, computes NM-ROMs for each, and then integrates these to form a global NM-ROM. This strategy offers multiple benefits: it enables parallel training of subdomain NM-ROMs, reduces the number of parameters needed, decreases the dimensional requirements of subdomain FOM training data, and allows for customization to the unique characteristics of each FOM subdomain. The use of a shallow, sparse autoencoder architecture in each subdomain NM-ROM facilitates the application of hyper-reduction (HR), simplifying the nonlinear complexities and enhancing computational speed. This software marks the inaugural application of NM-ROM combined with HR to a DD problem. It features an algebraic DD reformulation of the FOM, training of NM-ROMs with HR for each subdomain, and employs a sequential quadratic programming (SQP) solver for the evaluation of the coupled global NMROM. The effectiveness of the DD NM-ROM with HR is numerically demonstrated on the 2D steady-state Burgers' equation, showing an order of magnitude improvement in accuracy over the DD LS-ROM with HR.

Diaz, AlejandroN↗

Estimates of Tropical Diabatic Heating Profiles: Commonalities and Uncertainties

This study aims to evaluate the consistency and discrepancies in estimates of diabatic heating profiles associated with precipitation based on satellite observations and microphysics and those derived from the thermodynamics of the large-scale environment. It presents a survey of diabatic heating profile estimates from four Tropical Rainfall Measuring Mission (TRMM) products, four global reanalyses, and in situ sounding measurements from eight field campaigns at various tropical locations. Common in most of the estimates are the following: (i) bottom-heavy profiles, ubiquitous over the oceans, are associated with relatively low rain rates, while top-heavy profiles are generally associated with high rain rates; (ii) temporal variability of latent heating profiles is dominated by two modes, a deep mode with a peak in the upper troposphere and a shallow mode with a low-level peak; and (iii) the structure of the deep modes is almost the same in different estimates and different regions in the tropics. The primary uncertainty is in the amount of shallow heating over the tropical oceans, which differs substantially among the estimates.

54 ENVIRONMENTAL SCIENCES↗