Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Characterizing Surface Ice-Philicity Using Molecular Simulations and Enhanced Sampling

The formation of ice, which plays an important role in diverse contexts ranging from cryopreservation to atmospheric science, is often mediated by solid surfaces. Although surfaces that interact favorably with ice (relative to liquid water) can facilitate ice formation by lowering nucleation barriers, the molecular characteristics that confer ice-philicity to a surface are complex and incompletely understood. To address this challenge, here we introduce a robust and computationally efficient method for characterizing surface ice-philicity that combines molecular simulations and enhanced sampling techniques to quantify the free energetic cost of increasing surface–ice contact at the expense of surface–water contact. Using this method to characterize the ice-philicity of a family of model surfaces that are lattice matched with ice but vary in their polarity, we find that the nonpolar surfaces are moderately ice-phobic, whereas the polar surfaces are highly ice-philic. In contrast, for surfaces that display no complementarity to the ice lattice, we find that ice-philicity is independent of surface polarity and that both nonpolar and polar surfaces are moderately ice-phobic. Furthermore, our work thus provides a prescription for quantitatively characterizing surface ice-philicity and sheds light on how ice-philicity is influenced by lattice matching and polarity.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Accurate and efficient description of interacting carriers in quantum nanostructures by selected configuration interaction and perturbation theory

In this paper, we present a method to accurately and efficiently calculate many-body states of interacting carriers in quantum nanostructures based on a combination of iterative selection of configurations and perturbation theory. This method enables investigations of large excitonic complexes and multielectron systems with near full configuration interaction accuracy, even though only a small subspace of the full many-body Hilbert space is sampled, thus saving orders of magnitudes in computational resources. Important advantages of this method are that the convergence is controlled by a single parameter, the threshold, and that ground and excited states can be treated on an equal footing. On the example of InAsP nanowire quantum dots described using a million-atom tight-binding approach, we demonstrate the extreme efficiency of the method by numerical studies of large excitonic complexes filling up to the fourth electronic shell. We find that the method generally converges fast as a function of the threshold, profiting from a significant acceleration due to the perturbative corrections. The role of the choice of single-particle basis states is discussed. It is found that the algorithm converges faster in the Hartree-Fock basis only for highly charged systems, where Coulomb repulsion dominates. Finally, based on the observation that second-order perturbative energy corrections only depend on off-diagonal elements of the many-body Hamiltonian, we present a way to accurately calculate many-body states that requires only a relatively small number of Coulomb matrix elements.

36 MATERIALS SCIENCE↗

The effect of lighting environment on task performance in buildings – A review

The effects of indoor environmental conditions on human health, satisfaction, and performance have been the focal point of research for decades. This paper reviews and summarizes the impact of lighting environment on task performance, specifically for the built environment audience. Existing studies included a variety of performance tests on cognitive performance and perception, visual acuity and reaction, memory, reasoning, and labor productivity. Illuminance, luminance ratio and correlated color temperature were found to affect performance in different ways, reflecting the impact of experimental techniques, conditions, performance evaluation methods used and data analysis methods. These were reviewed and categorized, with discussion on limitations related to sample size, modeling approach, carryover effects and other factors affecting individual differences in performance, with recommendations for future improvement. Although no universal conclusions can be made, in general, task performance seems to improve with higher illuminances, contrast ratios in the range of 7–11:1 (while always making sure that glare will not occur in the space) and higher correlated color temperature, while spectral tuning in the red or blue wavelengths has also shown positive effects. To obtain more generic evidence, future studies should be more consistent in terms of experimental procedures and overall light conditions, and also consider the effects of vertical illuminance, daylight provision/control, and outside views on task performance. Finally, studying performance with multi-factorial designs in a human-centered optimized manner (such as deploying variable lighting scenarios optimized for various tasks) can lead to deeper understanding of lighting effects on task performance, and ultimately to improved lighting design and operation in buildings overall.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Uncertainty propagation and sensitivity analysis for constrained optimization of nuclear waste vitrification

Abstract The vitrification of high‐level waste (HLW) by heating a mixture of glass‐forming chemicals (GFCs) with the waste can be improved using a constrained optimization problem. This study explores how different uncertainty propagation (UP) methods implemented with the optimization process can affect the glass formulation of nuclear waste glasses. UP is the effort of propagating uncertain inputs through a system to understand and quantify output distributions. Uncertainty intervals are crafted from output distributions to inform the optimization algorithm. UP is often implemented with Monte Carlo (MC) sampling for large nonlinear systems, which can be difficult to implement within a constrained optimization algorithm that requires derivative information. Other UP methods often used for optimization under uncertainty (OUU) can be designed to work within an established constrained optimization framework. Methods of UP are evaluated in this study including iterative sampling approaches, first‐order approximations, and surrogate modeling with machine learning (ML). A method of dimensional reduction based on global sensitivity analysis is introduced to support the UP methods for the large dimensionality of the problem. Analytical UP methods able to achieve similar optimums 10 times faster than the baseline MC approach, and produce 93.9% similar output distributions are reported.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Accurately measuring the ionic conductivity of membranes via the direct contact method

Accurately measuring the ionic conductivity of membranes is important both for assessing the performance of new membranes as well as for advancing the fundamental understanding of electric field-driven ion transport in membranes. Yet, despite a considerable number of reports on the topic, there is no standardized method for ionic conductivity measurements. One of the main challenges with ionic conductivity measurements is isolating the membrane resistance from the other resistances in the electrochemical cell. In this study, we present a detailed discussion of factors that affect ionic conductivity measurements with the commonly used direct contact method, in which the membrane contacts the electrodes. Such factors include external resistances due to imperfect contact between the membrane and electrodes, residual impedances due to the sample holder and wiring, and fringe effects. Further, we also present and validate simple methods for isolating the true membrane ionic conductivity in both the through-plane and in-plane orientations. These methods can be implemented with virtually any membrane to obtain accurate and reproducible ionic conductivity values. Finally, we outline recommendations for performing ionic conductivity measurements with the direct contact method and a set of parameters to verify when reporting these results.

36 MATERIALS SCIENCE↗

Background measurement methods for opacity experiments conducted at the Z facility

Laboratory experiments typically test opacity models by measuring spectrally resolved transmission of a sample using bright backlight radiation. A potential problem is that any unaccounted background signal contaminating the spectrum will artificially reduce the inferred opacity. Methods developed to measure background signals in opacity experiments at the Sandia Z facility are discussed. Preliminary measurements indicate that backgrounds are 9%–11% of the backlight signal at wavelengths less than 10 Å. Background is thus a relatively modest correction for all Z opacity data published to date. Future work will determine how important background is at longer wavelengths.

47 OTHER INSTRUMENTATION↗

A substandard candle: the low-$$\nu $$ method at few-GeV neutrino energies

Abstract As accelerator-based neutrino oscillation experiments improve oscillation parameter constraints with more data, control over systematic uncertainties on the incoming neutrino flux and interaction models is increasingly important. The intense beams offered by modern experiments permit a variety of options to constrain the flux using in situ “standard candle” measurements. These standard candles must use very well understood interaction processes to avoid introducing additional interaction model dependence. One option often discussed in this context is the “low- $$\nu $$ ν ” method, which is designed to isolate neutrino interactions where there is low energy-transfer to the nucleus, such that the interaction cross section is expected to be approximately constant as a function of neutrino energy. The shape of the low-energy transfer event sample can then be used to extract the flux shape. Applications of the method at high neutrino energies (many tens of GeV) are well understood. However, the applicability of the method at the lower energies of current and future few-GeV accelerator neutrino experiments remains unclear due to the presence of nuclear and form-factor effects inherent in the interaction models.In this analysis we examine the prospects for improving constraints on the accelerator neutrino fluxes in situ with the low- $$\nu $$ ν method in an experiment-independent way, using (anti)neutrino interactions on argon and hydrocarbon targets from the GENIE, NEUT, NuWro and GiBUU event generators. We begin by investigating the extent to which deviations from the constant cross-section assumption are dependent on poorly understood aspects of the neutrino interaction model. We then assess whether a low energy-transfer event sample can be confidently identified using experimentally accessible observables. We finally consider how the practicalities of reconstructing the energy spectrum of interacting neutrinos in realistic detectors might further limit the utility of low- $$\nu $$ ν flux constraints. The results show that flux constraints from the low- $$\nu $$ ν method would be severely dependent on the interaction model assumptions used in an analysis of neutrinos with energies below 5 GeV, and anti-neutrinos below at least 15 GeV. The spread of model predictions show that a low- $$\nu $$ ν analysis is unlikely to offer much improvement on typical neutrino flux uncertainties, even with a perfect detector. Notably—running counter to the assumption inherent to the low- $$\nu $$ ν method—the model-dependence increases with decreasing energy transfer for experiments in the few-GeV region.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

The impact of spectroscopic incompleteness in direct calibration of redshift distributions for weak lensing surveys

ABSTRACT Obtaining accurate distributions of galaxy redshifts is a critical aspect of weak lensing cosmology experiments. One of the methods used to estimate and validate redshift distributions is to apply weights to a spectroscopic sample, so that their weighted photometry distribution matches the target sample. In this work, we estimate the selection bias in redshift that is introduced in this procedure. We do so by simulating the process of assembling a spectroscopic sample (including observer-assigned confidence flags) and highlight the impacts of spectroscopic target selection and redshift failures. We use the first year (Y1) weak lensing analysis in Dark Energy Survey (DES) as an example data set but the implications generalize to all similar weak lensing surveys. We find that using colour cuts that are not available to the weak lensing galaxies can introduce biases of up to Δz ∼ 0.04 in the weighted mean redshift of different redshift intervals (Δz ∼ 0.015 in the case most relevant to DES). To assess the impact of incompleteness in spectroscopic samples, we select only objects with high observer-defined confidence flags and compare the weighted mean redshift with the true mean. We find that the mean redshift of the DES Y1 weak lensing sample is typically biased at the Δz = 0.005−0.05 level after the weighting is applied. The bias we uncover can have either sign, depending on the samples and redshift interval considered. For the highest redshift bin, the bias is larger than the uncertainties in the other DES Y1 redshift calibration methods, justifying the decision of not using this method for the redshift estimations. We discuss several methods to mitigate this bias.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of DoS Attacks Using ARFIMA Modeling of GOOSE Communication in IEC 61850 Substations

Integration of Information and Communication Technology (ICT) in modern smart grids (SGs) offers many advantages including the use of renewables and an effective way to protect, control and monitor the energy transmission and distribution. To reach an optimal operation of future energy systems, availability, integrity and confidentiality of data should be guaranteed. Research on the cyber-physical security of electrical substations based on IEC 61850 is still at an early stage. In the present work, we first model the network traffic data in electrical substations, then, we present a statistical Anomaly Detection (AD) method to detect Denial of Service (DoS) attacks against the Generic Object Oriented Substation Event (GOOSE) network communication. According to interpretations on the self-similarity and the Long-Range Dependency (LRD) of the data, an Auto-Regressive Fractionally Integrated Moving Average (ARFIMA) model was shown to describe well the GOOSE communication in the substation process network. Based on this ARFIMA-model and in view of cyber-physical security, an effective model-based AD method is developed and analyzed. Two variants of the statistical AD considering statistical hypothesis testing based on the Generalized Likelihood Ratio Test (GLRT) and the cumulative sum (CUSUM) are presented to detect flooding attacks that might affect the availability of the data. Our work presents a novel AD method, with two different variants, tailored to the specific features of the GOOSE traffic in IEC 61850 substations. The statistical AD is capable of detecting anomalies at unknown change times under the realistic assumption of unknown model parameters. The performance of both variants of the AD method is validated and assessed using data collected from a simulation case study. We perform several Monte-Carlo simulations under different noise variances. The detection delay is provided for each detector and it represents the number of discrete time samples after which an anomaly is detected. In fact, our statistical AD method with both variants (CUSUM and GLRT) has around half the false positive rate and a smaller detection delay when compared with two of the closest works found in the literature. Our AD approach based on the GLRT detector has the smallest false positive rate among all considered approaches. Whereas, our AD approach based on the CUSUM test has the lowest false negative rate thus the best detection rate. Depending on the requirements as well as the costs of false alarms or missed anomalies, both variants of our statistical detection method can be used and are further analyzed using composite detection metrics.

IEC 61850 electrical substations↗

Unbalanced Nested Random Effects Estimation of Variance Components

To investigate the contributing factors of variance in the measurement of an iodine 127 (127I) sample, we implement a nested random effects analysis of variance (ANOVA). Historically, the reported uncertainty on a measurement of 127I has been obtained by methods of forward uncertainty propagation because there is typically only one replicate of a given sample for which to estimate the uncertainty. When samples are processed there are several types of quality control (QC) standards analyzed along-side the unknown samples with two to five replicates for each. Assuming the variance observed in these replicate QC standards is representative of that of the unknown samples, we use these data in a nested random effects ANOVA to estimate the total uncertainty of a measurement. We demonstrate this approach with two sets of measurements from Idaho National Laboratory and compare the results with the forward uncertainty propagation approach. Variance component estimates for the coarsest level of the nesting structure were most imprecise because replicates were most limited at these levels. We find that the results largely agree between forward propagation and ANOVA, and the greatest contributors of variance are due to instrument variation and chemical processing, with human processing being among the smallest contributors. This analysis provides reassurance that the reported uncertainties using forward propagation are reasonable and the process is well controlled. We propose a future designed experiment to increase replicates at the coarsest level of the hierarchy to improve estimates of these variance components.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A Generation-Storage Coordination Dispatch Strategy for Power System Based on Causal Reinforcement Learning

In the backdrop of global energy transformation, power systems integrating high proportions of renewable energy sources are facing unprecedented challenges in operational stability and dispatch efficiency. To address these challenges, this study introduces a generation-storage coordination real-time dispatch strategy based on Causal Power System Dynamic Reinforcement Learning (CPSDRL). Diverging from traditional reinforcement learning approaches, CPSDRL innovatively incorporates causal inference within the state prediction model - the crux of model-based reinforcement learning - thereby establishing the Power Causal Dynamic Model (PCDM). Assisted by the prior knowledge of power systems, the model significantly enhances prediction accuracy and reliability through a two-stage training process. Utilizing PCDM, this study further applies a direct policy search algorithm to optimize the real-time dispatch strategy. Experimental results indicate that the proposed method improves the stability of generation-storage coordination real-time dispatch and exhibits competitive advantages in sample efficiency and computational speed, compared to traditional model-based and model-free reinforcement learning algorithms. This method is expected to enhance the practicality and adaptability of causal reinforcement learning techniques in power system scheduling and control.

causal reinforcement learning↗

Covariance matrices for variance-suppressed simulations

ABSTRACT Cosmological N-body simulations provide numerical predictions of the structure of the Universe against which to compare data from ongoing and future surveys, but the growing volume of the Universe mapped by surveys requires correspondingly lower statistical uncertainties in simulations, usually achieved by increasing simulation sizes at the expense of computational power. It was recently proposed to reduce simulation variance without incurring additional computational costs by adopting fixed-amplitude initial conditions. This method has been demonstrated not to introduce bias in various statistics, including the two-point statistics of galaxy samples typically used for extracting cosmological parameters from galaxy redshift survey data, but requires us to revisit current methods for estimating covariance matrices of clustering statistics for simulations. In this work, we find that it is not trivial to construct covariance matrices analytically for fixed-amplitude simulations, but we demonstrate that ezmock (Effective Zel’dovich approximation mock catalogue), the most efficient method for constructing mock catalogues with accurate two- and three-point statistics, provides reasonable covariance matrix estimates for such simulations. We further examine how the variance suppression obtained by amplitude-fixing depends on three-point clustering, small-scale clustering, and galaxy bias, and propose intuitive explanations for the effects we observe based on the ezmock bias model.

79 ASTRONOMY AND ASTROPHYSICS↗

Optimized Microwave Digestion and Quantification Procedure for Boron Carbide samples

A microwave-assisted HNO3-H2SO4-HF digestion system was explored/optimized for the total dissolution of Boron Carbide samples followed by multi-elemental determination using ICP-MS and ICP OES, in order to improve the methods used in a previous try using a microwave-assisted H2O2-HNO3-HF digestion system. The samples were microwave digested to accomplish complete dissolution needed to perform quantitative analysis of their metal content. Two Boron Carbide samples were provided to us: JM10 and JM11. The Boron Carbide samples were completely dissolved at the end of the optimized microwave digestion procedure that was developed. The digested samples were analyzed for metals mostly by ICP MS; few elements were analyzed by ICP-OES. Microwave digestion reactions were performed in a Titan MPS instrument (Perkin Elmer, USA). Titan MPS instrument is equipped with Temperature and Pressure regulations and controlled by software. Each microwave digestion batch contained the samples of interest along with a reagent blank and one certified standard (1632e) in order to (i) compensate for the contaminations present in the reagents, (ii) ensure that the digestion was complete and (iii) that there was a good recovery of all the constituents. The certified standard used (1632e) was provided with USGS certificates of analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AutoSAC-Automated Sample Activation Calculation on VULCAN

AutoSAC is an automated python program to conduct sample activation calculation immediately after neutron scattering experiment on VULCAN. AutoSAC takes account of sample dimensions, compositions, forms, sample environments, neutron beam configurations, neutron scattering history, and proton charged resolved beam power etc., and uses a simplified method to rapidly estimate the radioactivity at end of beam or after. It generates a draft report per sample and repository of radioactivity per measurement and provides feedback of current radioactivity and decay time back to a neutron proposal Slack channel to inform users immediately on sample handling. It also utilizes either the sample note field in EPICS or sample composition or thickness correction and takes slack prompt or command to conduct post-beam SAC by demand. The program can be shared to be used in other beamlines at spallation neutron source with modified instrument configurations including instrument specific characteristic beam fluxes.

An, Ke [Oak Ridge National Laboratory (ORNL), Oak ↗

Exploring Charged Defects in Ferroelectrics by the Switching Spectroscopy Piezoresponse Force Microscopy

Monitoring the charged defect concentration at the nanoscale is of critical importance for both the fundamental science and applications of ferroelectrics. However, up-to-date, high-resolution study methods for the investigation of structural defects, such as transmission electron microscopy, X-ray tomography, etc., are expensive and demand complicated sample preparation. Here, with an example of the lanthanum-doped bismuth ferrite ceramics, a novel method is proposed based on the switching spectroscopy piezoresponse force microscopy (SSPFM) that allows probing the electric potential from buried subsurface charged defects in the ferroelectric materials with a nanometer-scale spatial resolution. When compared with the composition-sensitive methods, such as neutron diffraction, X-ray photoelectron spectroscopy, and local time-of-flight secondary ion mass spectrometry, the SSPFM sensitivity to the variation of the electric potential from the charged defects is shown to be equivalent to less than 0.3 at% of the defect concentration. Additionally, the possibility to locally evaluate dynamics of the polarization screening caused by the charged defects is demonstrated, which is of significant interest for further understanding defect-mediated processes in ferroelectrics.

42 ENGINEERING↗

Development of Nontargeted Workflow of Occupational Exposure by Infrared Ion Spectroscopy and Silicone Wristbands’ Passive Sampling

Monitoring chemical exposure has well-established protocols and procedures for occupational health and industrial hygiene across various career fields and in a variety of occupational and environmental conditions. Iterative analytical development has led to validated methods to provide employers and employees with safe working conditions in terms of industrial hygiene. These validated methods are commonly supported by commercial laboratories. Here, this workflow is explicitly a targeted approach in which sampling media, sample preparation, chemical separation, quantitative target detection, and post processing are well established. This workflow also relies on commercially available chemical surrogates, isotopically labeled internal standards, and certified/standard reference materials from reputable vendors. An untargeted workflow lacks many key ingredients of validated analytical methods to include the known chemical target.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using the Monte Carlo Method to Evaluate the Reliability of Screening Multifamily Housing for Radon

When screening for radon in a multifamily housing complex using a fixed sample density (e.g., testing 1 in 10 (10%) or 1 in 4 units (25%)), the statistical confidence is dependent upon the assumed elevated radon frequency. For example, testing 25% of units in a complex estimated to have eight units with elevated radon levels will provide 90% confidence. However, if it is assumed that, in the same complex, there are only three units with elevated radon levels, the confidence drops to around 58% for the same sample density. Furthermore, in the previous example, if elevated radon levels are not found during the screening, all that can be stated is that the screening provides 90% confidence that there are no more than seven units in the complex with elevated radon levels. To more fully illustrate this uncertainty, ten separate multifamily housing radon data sets with 1 to 10 units with radon levels ≥4 pCi/L (Table 1) were selected for analysis using the Monte Carlo statistical method. Unlike other mathematically based statistical approaches, the Monte Carlo statistical method relies on repeated analysis of randomly selected data. from a 100% sampled complex at various sample densities. Success for each simulation is defined as finding at least one unit with elevated radon levels. In this statistical method, confidence in the overarching conclusion can be greatly enhanced by repeating the simulated screening hundreds or even thousands of times. For this study, each of the ten data sets was simulated 1,000 times. For each simulation, the data set was randomized three times before the fixed percentage of data was selected.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Infrared quantum ghost imaging of living and undisturbed plants

Quantum ghost imaging (QGI) is a method that measures absorption at extremely low light intensities. Nondegenerate QGI probes a sample at one wavelength while forming an image with correlated photons at a different wavelength. This spectral separation alleviates the need for imaging detectors with high sensitivity in the near-infrared (NIR) region, thereby reducing the required illumination intensity. Using NCam, a single-photon detector, we demonstrated nondegenerate QGI with unprecedented sensitivity and contrast, obtaining images of living plants with less than 1% light transmission. The plants experienced 3aW/cm 2 of light during imaging, orders of magnitude below starlight. This realization of QGI expands the method to extremely low-light bioimaging and imaging of light-sensitive samples, where minimizing illumination intensity is crucial to prevent phototoxicity or sample degradation.

47 OTHER INSTRUMENTATION↗