Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “quantum technology”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 1,639 records · Page 91

Nonlinear frequency coupling in dual radio-frequency driven atmospheric pressure plasmas

Plasma ionization, and associated mode transitions, in dual radio-frequency driven atmospheric pressure plasmas are governed through nonlinear frequency coupling in the dynamics of the plasma boundary sheath. Ionization in low-power mode is determined by the nonlinear coupling of electron heating and the momentary local plasma density. Ionization in high-power mode is driven by electron avalanches during phases of transient high electric fields within the boundary sheath. The transition between these distinctly different modes is controlled by the total voltage of both frequency components.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Pressure-independent point in current-voltage characteristics of coplanar electrode microplasma devices operated in neon

We introduce the idea of a pressure-independent point (PIP) in a group of current-voltage curves for the coplanar electrode microplasma device (CEMPD) at neon pressures ranging from 15 to 95 kPa. We studied four samples of CEMPDs with different sizes of the microcavity and observed the PIP phenomenon for each sample. The PIP voltage depends on the area of the microcavity and is independent of the height of the microcavity. The PIP discharge current, I{sub PIP}, is proportional to the volume (Vol) of the microcavity and can be expressed by the formula I{sub PIP}=I{sub PIP0}+DxVol. For our samples, I{sub PIP0} (the discharge current when Vol is zero) is about zero and D (discharge current density) is about 3.95 mA mm{sup -3}. The error in D is 0.411 mA mm{sup -3} (less than 11% of D). When the CEMPD operates at V{sub PIP}, the discharge current is quite stable under different neon pressures.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generation of ultrahigh frequency air microplasma in a magnetic loop and effects of pulse modulation on operation

An atmospheric pressure air microplasma (APAMP) source was developed under ambient conditions using a magnetic loop at an operating frequency of 740 MHz. A self-igniting, stable APAMP was generated at 9.5 W. Pulse modulation (PM) was applied to the ultra high frequency signal. The effects of PM on self-ignition and operation of the APAMP source were studied by using a square wave modulating signal in the frequency range of 5-30 KHz. With the application of PM on the APAMP, in the best case, the plasma self-ignites and is sustained at 2.5 W.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

In situ determination of the static inductance and resistance of a plasma focus capacitor bank

The static (unloaded) electrical parameters of a capacitor bank are of utmost importance for the purpose of modeling the system as a whole when the capacitor bank is discharged into its dynamic electromagnetic load. Using a physical short circuit across the electromagnetic load is usually technically difficult and is unnecessary. The discharge can be operated at the highest pressure permissible in order to minimize current sheet motion, thus simulating zero dynamic load, to enable bank parameters, static inductance L{sub 0}, and resistance r{sub 0} to be obtained using lightly damped sinusoid equations given the bank capacitance C{sub 0}. However, for a plasma focus, even at the highest permissible pressure it is found that there is significant residual motion, so that the assumption of a zero dynamic load introduces unacceptable errors into the determination of the circuit parameters. To overcome this problem, the Lee model code is used to fit the computed current trace to the measured current waveform. Hence the dynamics is incorporated into the solution and the capacitor bank parameters are computed using the Lee model code, and more accurate static bank parameters are obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Accuracy and precision in photonic Doppler velocimetry

While photonic Doppler velocimetry (PDV) is becoming a common diagnostic in dynamic compression research, its limiting accuracy and precision are not well understood. Velocity resolution is known to be inversely proportional to the time resolution, but resolution estimates differ by one to two orders of magnitude. Furthermore, resolution varies with the number of recorded signals and how these signals are analyzed. Numerical simulations reveal factors that affect accuracy and precision in PDV, and the results may be extended to a broad class of measurements. After systematic effects are eliminated, the limiting velocity uncertainty in a PDV measurement is governed by the sampling rate, the signal noise fraction, and the analysis time duration.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Geometry of plasma dynamics. I. Group of canonical diffeomorphisms

The dynamics of collisionless plasma described by the Poisson-Vlasov equations is connected to the Hamiltonian motions of particles and their symmetries. The group of canonical diffeomorphisms of particle phase space is described and adopted as the configuration space. The dual space of its Lie algebra of Hamiltonian vector fields is identified with the space of nonclosed one-forms. The Poisson equation is obtained as a constraint arising from the gauge symmetries of particle dynamics. Variational derivative constrained by the Poisson equation is used to obtain reduced dynamical equations. Usual Lie-Poisson reduction for the group of canonical diffeomorphisms gives the momentum-Vlasov equations. Plasma density is defined as the divergence of symplectic dual of momentum variables. This definition is also given a momentum map description associated with the action of additive group of functions of particle phase space. Equivalence of Hamiltonian functionals in momentum and density formulations is shown. As an alternative formulation in momentum variables, a canonical Hamiltonian system with a quadratic Hamiltonian functional is described. In the case that the groups of Hamiltonian and volume preserving diffeomorphisms coincide, a comparison of one-dimensional plasma and two-dimensional incompressible fluid is presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Note: X-ray streak camera sweep speed calibration

X-ray streak cameras are extensively used to study transient x-ray processes in experiments carried out on various laser facilities at the Research Center of Laser Fusion. Precise calibration and clear description of the sweep speed of the x-ray streak camera are vital for obtaining precise temporal information to understand the fast physics phenomena. An x-ray streak camera named wide-slit x-ray streak camera has been calibrated using a small-scale laser facility with pulse duration of 8 ps. Sweep speeds on most part of the output screen (charge coupled device) are obtained. These calibration results can be used to correct the nonlinearity of sweep speed in measurement of temporal processes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

{sup 85}Rb tunable-interaction Bose-Einstein condensate machine

We describe our experimental setup for creating stable Bose-Einstein condensates (BECs) of {sup 85}Rb with tunable interparticle interactions. We use sympathetic cooling with {sup 87}Rb in two stages, initially in a tight Ioffe-Pritchard magnetic trap and subsequently in a weak, large-volume, crossed optical dipole trap, using the 155 G Feshbach resonance to manipulate the elastic and inelastic scattering properties of the {sup 85}Rb atoms. Typical {sup 85}Rb condensates contain 4x10{sup 4} atoms with a scattering length of a=+200a{sub 0}. Many aspects of the design presented here could be adapted to other dual-species BEC machines, including those involving degenerate Fermi-Bose mixtures. Our minimalist apparatus is well suited to experiments on dual-species and spinor Rb condensates, and has several simplifications over the {sup 85}Rb BEC machine at JILA, which we discuss at the end of this article.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurement of electron temperature and ion density using the self-bias effect in plasmas

For novel plasma diagnostics, the rf floating probe was revisited. For inducing the self-bias effect, ac bias voltage (approxkilohertz) was applied through a dc blocking capacitor between a probe and a signal generator. The dc self-bias potential was changed not only with ac bias voltages but also with electron temperatures, and therefore, the electron temperature was derived from the variations in the self-bias potential with and without ac bias voltage. The harmonic component of the probe contains information about the ion flux, and using a fast Fourier transform analysis of the probe current, the ion density was derived from the first harmonic current of the probe. The experimental results were compared with a single Langmuir probe. The electron temperature and the ion density were in good agreement with those from the Langmuir probe. Because the amplitude of the ac bias voltage is very low (<3 V), local ionizations affected by a high bias-voltage can be neglected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Free electron laser with bunched relativistic electron beam and electrostatic longitudinal wiggler

The system of the nonlinear nonstationary equations describing spatial-temporal dynamics of the amplitudes of an undulator radiation and a space charge wave of a relativistic electron beam in the resonator is obtained. The electrostatic longitudinal wiggler is considered. A bunch of the electron beam injects to the resonator, at the ends of which two mirrors are placed. After the interaction of electrons of bunch with radiation in the presence of wiggler and after amplifying electromagnetic pulse, a part of radiation is reflected back by semitransparent mirror. Then, it reaches to the initial of the system where the other mirror is placed. Synchronously, when the pulse is reflecting, the other electron bunch enters to the resonator and interacts with the pulse. This operation has simulated until saturation of growth of the electromagnetic pulse. The dynamics of the problem is simulated by the method of macro particles. The dynamics of pulse amplification, motion of the electrons, and spectra of output radiation in each stage are simulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High frequency, high time resolution time-to-digital converter employing passive resonating circuits

A method for measuring time intervals accurate to the picosecond range is based on phase measurements of oscillating waveforms synchronous with their beginning and/or end. The oscillation is generated by triggering an LC resonant circuit, whose capacitance is precharged. By using high Q resonators and a final active quenching of the oscillation, it is possible to conjugate high time resolution and a small measurement time, which allows a high measurement rate. Methods for fast analysis of the data are considered and discussed with reference to computing resource requirements, speed, and accuracy. Experimental tests show the feasibility of the method and a time accuracy better than 4 ps rms. Methods aimed at further reducing hardware resources are finally discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A two-dimensional modeling of the warm-up phase of a high-pressure mercury discharge lamp

The main objective of this work is to provide a better understanding of the warm-up phase of high-intensity discharge lamps. As an example of application, we chose the high-pressure mercury lamp. Based on two-dimensional fluid model parameters, such as the electric current, the length and the diameter of the burner are modified and the effect of the convective transport is studied. This allows us to obtain a thorough understanding of the physics of these lamps in their transitory phase. The simulation of the warm-up phase is a must for the proper predictions of the lamp behavior and can be conducted by solving the energy balance, momentum, and Laplace's equations for the plasma, using the frame of the local thermodynamic equilibrium coupled with the energy balance of the wall.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlinear Langmuir structures: Soliton and shock in a rotating weakly relativistic electron-positron magnetoplasma with stationary positive ions

Theoretical and numerical studies are performed for nonlinear Langmuir structures (soliton and shock) in a rotating weakly relativistic electron-positron magnetoplasma with background stationary positive ions. For this purpose, the reductive perturbation technique is employed to the weakly relativistic hydrodynamical electrons/positrons fluid equations and Poisson equation, obtaining extended Zakharov-Kuznetsov equation. The latter has been solved analytically. The features of the nonlinear excitations and their propagation conditions are investigated numerically. Our finding could elucidate the nonlinear electrostatic structures that propagate in astrophysical plasma situations where rotating, magnetized plasma can exist; such as polar cups region of pulsars, around active galactic nuclei, neutron stars, and white dwarfs.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Production of highly ionized species in high-current pulsed cathodic arcs

Time resolved optical diagnostic techniques were used to study the production of highly ionized species in aluminum plasma produced by a centered-triggered high-current pulsed cathodic arc. Controlling the spacing between cathode spots enabled a correlation between a reduction in the mean charge state and an increase in the spacing of cathode spots to be observed. As the cathode current was increased, the distances between spots were reduced and these charge states were produced for longer times. Strong cathode spot coupling is proposed as a mechanism for the production of high charge states.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Chirped pulse shadowgraphy for single shot time resolved plasma expansion measurements

The dynamics of ultrashort laser plasmas demand single shot temporal measurements on fast time scales. We describe a method to record the plasma expansion on picosecond (ps) timescales continuously over hundreds of ps, in single shot. The method uses the chirp of a Ti:sapphire laser as a time-resolved optical diagnostic tool. Using this technique, the evolution of the plasma expansion had been recorded with ps time resolutions, by probing with a chirped laser pulse of 200 ps duration. A peak expansion velocity of 1.8x10{sup 7} cm/s is observed and its evolution in time is obtained for approx300 ps.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Linear study of the nonmodal growth of drift waves in dusty plasmas

The main effect of dust on drift wave turbulence is the enhancement of the nonadiabaticity. Previous work found that nonmodal behavior is important in the nonadiabatic regime of the drift wave system. Here, the modal and nonmodal properties of the linear Hasegawa-Wakatani system of dusty plasmas are investigated. The non-normality of the linear evolution operator can lead to enhanced transient growth rates compared to the modal growth rates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of dust size distribution on instability of obliquely propagating waves in a magnetized dusty plasma

In the present paper, the obliquely propagating solitary waves are investigated in a magnetized dusty plasma considering vortexlike ion distribution and dust size distribution. A plane solitary traveling-wave solution propagating at an arbitrary angle to the magnetic field is considered. The growth rate caused by small perturbations of any direction to a solitary traveling waves is studied. The effects of the dust size distribution and perturbations on the growth rate are discussed in detail.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Magnetized plasma flows and magnetoplasmadynamic thrusters

An axisymmetric magnetohydrodynamics (MHD) model of the acceleration channel of an applied-field magnetoplasmadynamic thruster is presented. A set of general relationships between the flow features and the thruster performance is obtained. The boundary conditions and the flow regime, which depends on the Alfven Mach number, are shown to provide the ideal limits of steady state thruster operation. In the present analysis, a Hamiltonian formulation of the MHD plasma flow model is adopted. This formulation makes it possible to cast the model equations in a variational form, which is then solved by using a finite element numerical algorithm.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗